1
|
Cao W, Zhang S, Liu Q, Zhou J, Yuan X. Changes of dysfunctional lens index before and after implantable collamer lens V4c implantation in patients with moderate-to-high myopia. Int Ophthalmol 2023; 43:4111-4120. [PMID: 37480477 PMCID: PMC10520214 DOI: 10.1007/s10792-023-02812-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Accepted: 07/10/2023] [Indexed: 07/24/2023]
Abstract
BACKGROUND Dysfunctional lens index (DLI) changing is rarely reported after implantable collamer lens (ICL) implantation. In the current research, we hope to investigate the changes of DLI by ray-tracing aberrometry before and after implantation of the posterior chamber phakic implantable collamer lens with a central artificial hole for patients with moderate-to-high myopia. METHODS This retrospective, observational case series included 206 eyes of 104 patients with moderate-to-high myopia who underwent ICL V4c implantation. Data were collected on ocular indicators preoperatively and at 1 day, 1, 3, and 6 months postoperatively. The i-Trace Visual Functional Analyzer was used to assess the DLI measurement. RESULTS The overall values of safety index and efficacy index were both more than 1. Preoperatively, the mean spherical equivalent (SE) of included 206 eyes was - 10.77 ± 3.46 diopter (D). Then at 1-day postoperation, the mean SE was - 0.22 ± 0.55 D, and barely changed from 1 day to 6 months postoperatively. Although the endothelial parameters had no significant differences between preoperation and postoperation, the mean loss of endothelial cells was 0.74 ± 0.98% at 6 months. Regarding the vault, there was a significant difference between each time of follow-up (P < 0.001). The mean of the vault decreased 109.6 ± 13.5 µm from 1-day post-op to 6 months post-op. The DLI values were 3.70, 9.26, 10.00, and 9.68 at baseline, 1, 3, and 6 months, respectively (P < 0.001), but no significant differences were found between 1, 3, and 6 months postoperatively (P > 0.05). The preoperative lnDLI showed a significant positive linear correlation (r = 0.621, P < 0.001) with the preoperative spherical equivalent (SE). The lnDLI was negatively correlated with the axial length (r = - 0.462, P < 0.001), corneal thickness (r = - 0.207, P = 0.003), preoperative LogMAR UDVA (r = - 0.189, P = 0.006), and preoperative LogMAR CDVA (r = - 0.306, P < 0.001). CONCLUSIONS The postoperative refractive parameters were confirmed excellent in efficacy, predictability, and stability in half a year. The DLI was significantly improved after the ICL V4c implantation in patients with moderate-to-high myopia and showed good stability during the follow-up periods. The DLI deserves a more comprehensive understanding and application in clinical services.
Collapse
Affiliation(s)
- Weifang Cao
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, 300070, China
- Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Tianjin, 300020, China
- Department of Cataract, Shanxi Eye Hospital, Taiyuan, 030002, Shanxi Province, China
| | - Suhua Zhang
- Department of Cataract, Shanxi Eye Hospital, Taiyuan, 030002, Shanxi Province, China
| | - Qian Liu
- Department of Cataract, Shanxi Eye Hospital, Taiyuan, 030002, Shanxi Province, China
| | - Jing Zhou
- Department of Cataract, Shanxi Eye Hospital, Taiyuan, 030002, Shanxi Province, China
| | - Xiaoyong Yuan
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, 300070, China.
- Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Tianjin, 300020, China.
| |
Collapse
|
2
|
Wu CZ, Jin H, Shen ZN, Li YJ, Cui X. Wavefront aberrations and retinal image quality in different lenticular opacity types and densities. Sci Rep 2017; 7:15247. [PMID: 29127310 PMCID: PMC5681554 DOI: 10.1038/s41598-017-15245-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2017] [Accepted: 10/24/2017] [Indexed: 11/25/2022] Open
Abstract
To investigate wavefront aberrations in the entire eye and in the internal optics (lens) and retinal image qualities according to different lenticular opacity types and densities. Forty-one eyes with nuclear cataract, 33 eyes with cortical cataract, and 29 eyes with posterior subcapsular cataract were examined. In each group, wavefront aberrations in the entire eye and in the internal optics and retinal image quality were measured using a raytracing aberrometer. Eyes with cortical cataracts showed significantly higher coma-like aberrations compared to the other two groups in both entire eye and internal optic aberrations (P = 0.012 and P = 0.007, respectively). Eyes with nuclear cataract had lower spherical-like aberrations than the other two groups in both entire eye and internal optics aberrations (P < 0.001 and P < 0.001, respectively). In the nuclear cataract group, nuclear lens density was negatively correlated with internal spherical aberrations (r = −0.527, P = 0.005). Wavefront technology is useful for objective and quantitative analysis of retinal image quality deterioration in eyes with different early lenticular opacity types and densities. Understanding the wavefront optical properties of different crystalline lens opacities may help ophthalmic surgeons determine the optimal time to perform cataract surgery.
Collapse
Affiliation(s)
- Cheng-Zhe Wu
- Department of Ophthalmology, Affiliated Hospital of Yanbian University, Yanji Jilin, 133-000, China
| | - Hua Jin
- Department of Ophthalmology, Affiliated Hospital of Yanbian University, Yanji Jilin, 133-000, China
| | - Zhen-Nv Shen
- Department of Ophthalmology, Affiliated Hospital of Yanbian University, Yanji Jilin, 133-000, China
| | - Ying-Jun Li
- Department of Ophthalmology, Affiliated Hospital of Yanbian University, Yanji Jilin, 133-000, China.
| | - Xun Cui
- Department of Physiology and Pathophysiology, School of Medical Sciences, Yanbian University, Yanji Jlin, 133-002, China.
| |
Collapse
|
3
|
Whang WJ, Piao J, Yoo YS, Joo CK, Yoon G. The efficiency of aspheric intraocular lens according to biometric measurements. PLoS One 2017; 12:e0182606. [PMID: 29036175 PMCID: PMC5642893 DOI: 10.1371/journal.pone.0182606] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2016] [Accepted: 07/23/2017] [Indexed: 12/03/2022] Open
Abstract
Purpose To analyze internal spherical aberration in pseudophakic eyes that underwent aspheric intraocular lens (IOL) implantation, and to investigate the relationships between biometric data and the effectiveness of aspheric IOL implantation. Methods This retrospective study included 40 eyes of 40 patients who underwent implantation of an IOL having a negative spherical aberration of -0.20 μm (CT ASPHINA 509M; Carl Zeiss Meditec Inc., Germany). The IOLMaster (version 5.0; Carl Zeiss AG, Germany) was used for preoperative biometric measurements (axial length, anterior chamber depth, central corneal power) and the measurement of postoperative anterior chamber depth. The spherical aberrations were measured preoperatively and 3 months postoperatively using the iTrace (Tracey Technologies, Houston, TX, USA) at a pupil diameter of 5.0 mm. We investigated the relationships between preoperative biometric data and postoperative internal spherical aberration, and compared biometric measurements between 2 subgroups stratified according to internal spherical aberration (spherical aberration ≤ -0.06 μm vs. spherical aberration > -0.06 μm). Results The mean postoperative internal spherical aberration was -0.087 ± 0.063 μm. Preoperative axial length and residual total spherical aberration showed statistically significant correlations with internal spherical aberration (p = 0.041, 0.002). Preoperative axial length, postoperative anterior chamber depth, IOL power, and residual spherical aberration showed significant differences between the 2 subgroups stratified according to internal spherical aberration (p = 0.020, 0.029, 0.048, 0.041 respectively). Conclusion The corrective effect of an aspheric IOL is influenced by preoperative axial length and postoperative anterior chamber depth. Not only the amount of negative spherical aberration on the IOL surface but also the preoperative axial length should be considered to optimize spherical aberration after aspheric IOL implantation.
Collapse
Affiliation(s)
- Woong-Joo Whang
- Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Junjie Piao
- Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Young-Sik Yoo
- Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Choun-Ki Joo
- Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
- * E-mail:
| | - Geunyoung Yoon
- Flaum Eye Institute, Center for Visual Science, The Institute of Optics, University of Rochester, Rochester, New York, United States of America
| |
Collapse
|
4
|
Faria-Correia F, Ramos I, Lopes B, Monteiro T, Franqueira N, Ambrósio R. Comparison of Dysfunctional Lens Index and Scheimpflug Lens Densitometry in the Evaluation of Age-Related Nuclear Cataracts. J Refract Surg 2016; 32:244-8. [DOI: 10.3928/1081597x-20160209-01] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2015] [Accepted: 12/09/2015] [Indexed: 12/21/2022]
|
5
|
Monaco G, Scialdone A. Long-term outcomes of limbal relaxing incisions during cataract surgery: aberrometric analysis. Clin Ophthalmol 2015; 9:1581-7. [PMID: 26357459 PMCID: PMC4560521 DOI: 10.2147/opth.s89024] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
PURPOSE To compare the final changes in corneal wavefront aberration by limbal relaxing incisions (LRIs) after cataract surgery. METHODS This prospective cumulative interventional nonrandomized case study included cataract and astigmatic patients undergoing LRIs and phaco with intraocular lens implantation. LRIs were planned using Donnenfeld nomogram. The root mean square of corneal wave aberration for total Z(n,i)(1≤n≤8), astigmatism Z(2,±1), coma Z(3-5-7,±1), trefoil Z(3-5-7,±2), spherical Z(4-6-8,0), and higher-order aberration (HOA) Z(3≤n≤8) was examined before and 3 years after surgery (optical path difference-Scan II [OPD-Scan II)]. Uncorrected distance visual acuity and best-corrected distance visual acuity (CDVA) for distance, keratometric cylinder, and variations in average corneal power were also analyzed. RESULTS Sixty-four eyes of 48 patients were included in the study. Age ranged from 42 to 92 years (70.6±8.4 years). After LRIs, uncorrected distance visual acuity and best-corrected distance visual acuity improved statistically (P<0.01). The keratometric cylinder value decreased by 40.1%, but analysis of KP90 and KP135 polar values did not show any decrease that could be statistically confirmed (P=0.22 and P=0.24). No significant changes were detected in root mean square of total (P=0.61) and HOAs (P=0.13) aberrations. LRIs did not induce alteration in central corneal power confirming a 1:1 coupling ratio. CONCLUSION LRIs determined a nonsignificant alteration of corneal HOA. Therefore, LRIs can be still considered a qualitatively viable mean in those cases where toric intraocular lenses are contraindicated or not available. Yet, the authors raise the question of nonpersonalized nomograms, as in the present study, LRIs did not reach the preset target cylinder.
Collapse
Affiliation(s)
- Gaspare Monaco
- Department of Ophthalmology, Ospedale Fatebenefratelli e Oftalmico, Milan, Italy
| | - Antonio Scialdone
- Department of Ophthalmology, Ospedale Fatebenefratelli e Oftalmico, Milan, Italy
| |
Collapse
|
6
|
|
7
|
Lyall DAM, Srinivasan S, Gray LS. Changes in ocular monochromatic higher-order aberrations in the aging eye. Optom Vis Sci 2014; 90:996-1003. [PMID: 23839701 DOI: 10.1097/opx.0b013e31829cac79] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
PURPOSE To characterize corneal, internal, and total ocular monochromatic higher-order aberration (MHOA) changes that occur in the aging eye. METHODS Prospective observational case series including 300 eyes of 167 patients (mean age = 63.8 years) attending the ophthalmology service at University Hospital Ayr, Scotland. Corneal, internal, and total ocular aberrations were measured over a 6-mm dilated pupil. Zernike coefficients were obtained to the sixth order. Changes in MHOA between age groups and inter-eye correlations between right and left eyes were analyzed. RESULTS A significant inter-eye correlation was found for refractive mean spherical equivalent and cylinder. A significant inter-eye correlation for the whole eye, corneal, and internal MHOA was found (p < 0.001). Right eye analysis found a significant positive correlation between age and the root mean square of whole eye MHOA (p = 0.012), with an increase from 0.517 μm in the fifth decade to 0.824 μm in the ninth. Total internal MHOA increased from 0.411 to 0.704 μm. A significant positive correlation was found between age and internal fourth- (p = 0.007), fifth- (p = 0.029), and sixth-order (p = 0.025) root mean square aberrations. There were no significant age-related changes in corneal MHOA or corneal spherical aberration. Overall mean (SD) corneal SA was 0.203 (0.082) μm. CONCLUSIONS A strong correlation between the right and left eyes exists for MHOA. Whole eye MHOA increases with age. Such changes can be attributed to age-related changes in the internal optical quality of the eye. Such normative data are useful to the cataract surgeon when considering the use of an aspherical IOL to counteract corneal-induced SA during cataract surgery.
Collapse
Affiliation(s)
- Douglas A M Lyall
- Department of Ophthalmology, University Hospital Ayr, NHS Ayrshire and Arran, Glasgow, Scotland, United Kingdom
| | | | | |
Collapse
|
8
|
Barbero S. Wavefront aberration reconstruction from tangential refractive powers measured with spatial dynamic skiascopy. APPLIED OPTICS 2012; 51:8599-8605. [PMID: 23262600 DOI: 10.1364/ao.51.008599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2012] [Accepted: 11/17/2012] [Indexed: 06/01/2023]
Abstract
The aim of this work was to study, using numerical simulations, the attainable level of accuracy to reconstruct the wavefront aberrations from tangential refractive power data measured with dynamic skiascopy. Two mathematical methods have been implemented. The first one is based on curve integration of the curvature data, previously interpolated with cubic splines. The second one reconstructs the three-dimensional wavefront surface, represented by a Zernike polynomial expansion, using a two-step least-squares method. The different factors affecting the reconstruction--noise, sampling, and wavefront patterns--were quantified. The results provide useful information to design more efficient experimental setups based on spatial dynamic skiascopy.
Collapse
Affiliation(s)
- Sergio Barbero
- Instituto de Óptica, Consejo Superior de Investigaciones Científicas, Madrid, Spain.
| |
Collapse
|
9
|
Jun I, Choi YJ, Kim EK, Seo KY, Kim TI. Internal spherical aberration by ray tracing-type aberrometry in multifocal pseudophakic eyes. Eye (Lond) 2012; 26:1243-8. [PMID: 22744386 DOI: 10.1038/eye.2012.129] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To demonstrate the results of the ray tracing-type aberrometer in measuring spherical aberration (SA) in pseudophakic eyes with monofocal intraocular lens (IOL), aspheric monofocal IOL, or aspheric diffractive multifocal IOL. METHODS Total, corneal, and internal SA were measured using iTrace at a 6-mm pupil size in 27 eyes of 27 patients implanted with a monofocal spherical IOL (group 1: Natural, SN60AT), 30 eyes of 30 patients implanted with a monofocal aspheric IOL (group 2: IQ, SN60WF), and 30 eyes of 30 patients implanted with a multifocal aspheric IOL (group 3: ReSTOR, SN6AD1) at 3 months after cataract surgery. We compared the internal SAs of these IOLs in pupil sizes of 3, 4, 5, and 6 mm. RESULTS There were no demographic statistically significant differences among the groups. The internal SA of group 1 had a positive value. The internal SA of group 2 was -0.175 ± 0.135 μm in 5-mm pupils and -0.227 ± 0.253 μm in 6-mm pupils. The internal SA of group 3 was -0.072 ± 0.128 μm in 5-mm pupils and -0.173 ± 0.231 μm in 6-mm pupils. CONCLUSION Measuring internal SA with iTrace yields relatively accurate results in all types of IOLs with adequate pupil sizes.
Collapse
Affiliation(s)
- I Jun
- Department of Ophthalmology, Institute of Vision Research, Yonsei University College of Medicine, Seoul, South Korea
| | | | | | | | | |
Collapse
|
10
|
In vivo Assessment of Higher-Order Aberrations after Acrysof Toric Intraocular Lens Implantation: A Comparative Study. Eur J Ophthalmol 2011; 22:531-40. [DOI: 10.5301/ejo.5000090] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/07/2011] [Indexed: 11/20/2022]
Abstract
Purpose To compare higher-order aberrations (HOAs) and optical quality in eyes implanted with AcrySof SN60TT toric intraocular lens (IOL) or with non-toric AcrySof SN60AT IOL (Alcon Laboratories, Inc., Fort Worth, TX). Methods This was a prospective, consecutive, nonrandomized, interventional, comparative study. One hundred eyes with cataract in 56 patients were included (SN60TT group, n=50; SN60AT group, n=50). Patients underwent phacoemulsification through a 2.2-mm temporal corneal incision. Postoperative HOAs, point spread function (PSF) and modulation transfer function (MTF), residual objective refractive astigmatism, and IOL alignment were evaluated using Optical Path Difference (OPD)–Scan II (Nidek, Gamagori, Japan). A novel technique to calculate IOL axis alignment was introduced. Results One year postoperatively, no statistical difference in corneal, intraocular, and total HOAs, Strehl ratio, and MTF based on HOAs was found between groups. Toric IOL patients had a net residual refractive astigmatism (M) of 0.44 D±0.47; the difference between expected and obtained astigmatism (M) was 0.043 D (p=0.16). Toric IOL axis misalignment was 2.65±2.39 degrees and no correlation with HOAs was found. Conclusions AcrySof SN60TT determines HOAs comparable to the non-toric version providing a good optical quality, and predictably corrects corneal cylinder with a stable postoperative alignment. The OPD-Scan II might be regarded as a fast and reliable method of toric IOL analysis.
Collapse
|
11
|
Schlegel Z, Lteif Y, Bains HS, Gatinel D. Total, corneal, and internal ocular optical aberrations in patients with keratoconus. J Refract Surg 2009; 25:S951-7. [PMID: 19848377 DOI: 10.3928/1081597x-20090915-10] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To measure and compare total, corneal, and internal ocular aberrations using combined wavefront analysis and corneal topography in eyes with keratoconus and eyes with normal corneas. METHODS This prospective study comprised eyes of patients with keratoconus and myopic patients seeking refractive surgery. Patients diagnosed with keratoconus and with a classification of "normal" or "keratoconus" on the NIDEK Corneal Navigator corneal disease screening software were selected for inclusion in this study. The normal group comprised eyes with a "normal" classification with 99% similarity. In the normal group, only one eye per patient was randomly selected based on a randomization schedule. Corneal, internal, and total wavefront measurements were provided by the NIDEK OPD-Scan II. RESULTS One hundred eyes with keratoconus and 155 normal eyes were enrolled in the study. Statistically significant higher corneal and internal higher order aberrations were observed in the eyes with keratoconus (P<.05). However, an increase in ocular higher order aberrations proportional to corneal higher order aberrations was not observed in the keratoconus group. CONCLUSIONS A compensatory effect of increased anterior corneal aberrations by internal aberrations in keratoconic eyes was present for some aberrations. The origin of this compensation and the optical mechanism behind it requires further study.
Collapse
Affiliation(s)
- Zuzana Schlegel
- Department of Ophthalmology, Rothschild Foundation, Paris, France
| | | | | | | |
Collapse
|