1
|
Ton N, Goncin U, Panahifar A, Webb MA, Chapman D, Wiebe S, Machtaler S. Developing a Microbubble-Based Contrast Agent for Synchrotron Multiple-Image Radiography. Mol Imaging Biol 2022; 24:590-599. [PMID: 35137326 DOI: 10.1007/s11307-022-01705-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Revised: 01/04/2022] [Accepted: 01/18/2022] [Indexed: 11/26/2022]
Abstract
PURPOSE Multiple-image radiography (MIR) is an analyzer-based synchrotron X-ray imaging approach capable of dissociating absorption, refraction, and scattering components of X-ray interaction with the material. It generates additional image contrast mechanisms (besides absorption), especially in the case of soft tissues, while minimizing absorbed radiation dose. Our goal is to develop a contrast agent for MIR using ultrasound microbubbles by carrying out a systematic assessment of size, shell material, and concentration. PROCEDURES Microbubbles were synthesized with two different shell materials: phospholipid and polyvinyl-alcohol. Polydisperse perfluorobutane-filled lipid microbubbles were divided into five size groups using centrifugation. Two distributions of air-filled polymer microbubbles were generated: 2-3 µm and 3-4 µm. A subset of polymer microbubbles 3-4 µm had iron oxide nanoparticles incorporated into their shell or coated on their surface. Microbubbles were immobilized in agar with different concentrations: 5 × 107, 5 × 106, and 5 × 105 MBs/ml. MIR was conducted on the BioMedical Imaging and Therapy beamline at the Canadian Light Source. Three images were generated: Gaussian amplitude, refraction, and ultra-small-angle X-ray scattering (USAXS). The contrast signal was quantified by measuring mean pixel values and comparing them with agar. RESULTS No difference was detected in absorption or refraction images of all tested microbubbles. Using USAXS, a significant signal increase was observed with lipid microbubbles 6-10 µm at the highest concentration (p = 0.02), but no signal was observed at lower concentrations. CONCLUSIONS These data indicate that lipid microbubbles 6-10 µm are candidates as contrast agents for MIR, specifically for USAXS. A minimum concentration of 5 × 107 microbubbles (lipid-shell 6-10 µm) per milliliter was needed to generate a detectable signal.
Collapse
Affiliation(s)
- Ngoc Ton
- Department of Medical Imaging, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | - Una Goncin
- Department of Medical Imaging, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | - Arash Panahifar
- Department of Medical Imaging, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
- Canadian Light Source, Saskatoon, Saskatchewan, Canada
| | - M Adam Webb
- Canadian Light Source, Saskatoon, Saskatchewan, Canada
| | - Dean Chapman
- Department of Anatomy, Physiology and Pharmacology, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
- Canadian Light Source, Saskatoon, Saskatchewan, Canada
| | - Sheldon Wiebe
- Department of Medical Imaging, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | - Steven Machtaler
- Department of Medical Imaging, University of Saskatchewan, Saskatoon, Saskatchewan, Canada.
- University of Saskatchewan, 107 Wiggins Rd, Saskatoon, Saskatchewan, S7N 5E5, Canada.
| |
Collapse
|
2
|
Ehsani M, Zhu N, Doan H, Lohi A, Abdelrasoul A. In-situ synchrotron X-ray imaging of ultrasound (US)-generated bubbles: Influence of US frequency on microbubble cavitation for membrane fouling remediation. ULTRASONICS SONOCHEMISTRY 2021; 77:105697. [PMID: 34388491 PMCID: PMC8361323 DOI: 10.1016/j.ultsonch.2021.105697] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 07/21/2021] [Accepted: 07/26/2021] [Indexed: 06/13/2023]
Abstract
Gaining an in-depth understanding of the characteristics and dynamics of ultrasound (US)--generated bubbles is crucial to effectively remediate membrane fouling. The goal of present study is to conduct in-situ visualization of US-generated microbubbles in water to examine the influence of US frequency on the dynamics of microbubbles. This study utilized synchrotron in-line phase contrast imaging (In-line PCI) available at the biomedical imaging and therapy (BMIT) beamlines at the Canadian Light Source (CLS) to enhance the contrast of liquid/air interfaces at different US frequencies of 20, 28 and 40 KHz at 60 Watts. A high-speed camera was used to capture 2,000 frames per second of the bubble cavitation generated in water under the ultrasound influence. Key parameters at the polychromatic beamlines were optimized to maximize the phase contrast of gas/liquid of the microbubbles with a minimum size of 5.5 µm. ImageJ software was used to analyze the bubble characteristics and their behavior under the US exposure including the microbubble number, size, and fraction of the total area occupied by the bubbles at each US frequency. Furthermore, the bubble characteristics over the US exposure time and at different distances from the transducer were studied. The qualitative and quantitative data analyses showed that the microbubble number or size did not change over time; however, it was observed that most bubbles were created at the middle of the frames and close to the US field. The number of bubbles created under the US exposure increased with the frequency from 20 kHz to 40 kHz (about 4.6 times). However, larger bubbles were generated at 20 kHz such that the average bubble radius at 20 kHz was about 6.8 times of that at 40 kHz. Microbubble movement/traveling through water was monitored, and it was observed that the bubble velocity increased as the frequency was increased from 20 kHz to 40 kHz. The small bubbles moved faster, and the majority of them traveled upward towards the US transducer location. The growth pattern (a correlation between the mean growth ratio and the exposure time) of bubbles at 20 kHz and 60 W was obtained by tracking the oscillation of 22 representative microbubbles over the 700 ms of imaging. The mean growth ratio model was also obtained.
Collapse
Affiliation(s)
- Masoume Ehsani
- Department of Chemical Engineering, Ryerson University, 350 Victoria St., Toronto, ON M5B 2K3, Canada
| | - Ning Zhu
- Canadian Light Source, Saskatoon, SK S7N 2V3, Canada
| | - Huu Doan
- Department of Chemical Engineering, Ryerson University, 350 Victoria St., Toronto, ON M5B 2K3, Canada.
| | - Ali Lohi
- Department of Chemical Engineering, Ryerson University, 350 Victoria St., Toronto, ON M5B 2K3, Canada
| | - Amira Abdelrasoul
- Department of Chemical and Biological Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada; Division of Biomedical Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada.
| |
Collapse
|
3
|
Olivo A. Edge-illumination x-ray phase-contrast imaging. JOURNAL OF PHYSICS. CONDENSED MATTER : AN INSTITUTE OF PHYSICS JOURNAL 2021; 33:363002. [PMID: 34167096 PMCID: PMC8276004 DOI: 10.1088/1361-648x/ac0e6e] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Revised: 06/07/2021] [Accepted: 06/24/2021] [Indexed: 05/08/2023]
Abstract
Although early demonstration dates back to the mid-sixties, x-ray phase-contrast imaging (XPCI) became hugely popular in the mid-90s, thanks to the advent of 3rd generation synchrotron facilities. Its ability to reveal object features that had so far been considered invisible to x-rays immediately suggested great potential for applications across the life and the physical sciences, and an increasing number of groups worldwide started experimenting with it. At that time, it looked like a synchrotron facility was strictly necessary to perform XPCI with some degree of efficiency-the only alternative being micro-focal sources, the limited flux of which imposed excessively long exposure times. However, new approaches emerged in the mid-00s that overcame this limitation, and allowed XPCI implementations with conventional, non-micro-focal x-ray sources. One of these approaches showing particular promise for 'real-world' applications is edge-illumination XPCI: this article describes the key steps in its evolution in the context of contemporary developments in XPCI research, and presents its current state-of-the-art, especially in terms of transition towards practical applications.
Collapse
Affiliation(s)
- Alessandro Olivo
- Department of Medical Physics and Biomedical Engineering, UCL, London, United Kingdom
| |
Collapse
|
4
|
Tang R, Li Y, Qin L, Yan F, Yang GY, Chen KM. Phase retrieval-based phase-contrast CT for vascular imaging with microbubble contrast agent. Med Phys 2021; 48:3459-3469. [PMID: 33657645 DOI: 10.1002/mp.14819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Revised: 02/15/2021] [Accepted: 02/23/2021] [Indexed: 11/11/2022] Open
Abstract
PURPOSE The introduction of microbubble contrast agent into tissues can create significant phase shifts. Phase retrieval (PR)-based phase-contrast computed tomography (PCCT) is an imaging method for retrieving and reconstructing the phase shifts within an object. This study aimed to evaluate the feasibility of PR-based PCCT with microbubble contrast agent for vascular imaging. METHODS Projection phase-contrast images of individual microbubbles and a cluster of microbubbles were captured and compared. Contrast enhancement from microbubbles was evaluated by comparing to the gold standard iodine-based contrast agent in vitro. The arterial systems of 14 Sprague-Dawley rats were perfused with microbubbles or saline. The rat hearts and the arterial systems were excised and imaged ex vivo. CT imaging was performed at the energy of 22 keV. PR was performed using the phase-attenuation duality (PAD) method with different δ/β values (PAD property). The contrast-to-noise ratio (CNR) was used for quantitatively assessing the contrast enhancement. RESULTS Individual microbubbles functioned as a lens to focus the x rays, whereas, a cluster of microbubbles scattered the x rays. In the in vitro experiment, the contrast enhancement from iodine was significantly greater than that from microbubbles (P < 0.05). In the heart samples, the CNRs for microbubbles on PR-based PCCT were significantly greater than those on absorption-contrast CT (ACCT) and PR-free PCCT (both P < 0.001). The CNRs for microbubbles were also significantly greater than those for saline on PR-based PCCT in the samples (P < 0.001). Although they provided weaker contrast enhancement than that from iodine, microbubbles could still provide sufficient contrast enhancement to clearly show the 3D architecture of rat aortas and their main branches. CONCLUSION The imaging modality can currently be used as a complement or alternative to absorption-based microCT for imaging vessels in biological samples.
Collapse
Affiliation(s)
- Rongbiao Tang
- Department of Radiology, Rui Jin Hospital, Shanghai Jiao Tong University, and School of Medicine, Shanghai, China
| | - Yongfang Li
- Department of Neurology, Rui Jin Hospital, Shanghai Jiao Tong University, and School of Medicine, Shanghai, China
| | - Le Qin
- Department of Radiology, Rui Jin Hospital, Shanghai Jiao Tong University, and School of Medicine, Shanghai, China
| | - Fuhua Yan
- Department of Radiology, Rui Jin Hospital, Shanghai Jiao Tong University, and School of Medicine, Shanghai, China
| | - Guo-Yuan Yang
- Med-X Research Institute and School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Ke-Min Chen
- Department of Radiology, Rui Jin Hospital, Shanghai Jiao Tong University, and School of Medicine, Shanghai, China
| |
Collapse
|
5
|
Notohamiprodjo S, Varasteh Z, Beer AJ, Niu G, Chen X(S, Weber W, Schwaiger M. Tumor Vasculature. Mol Imaging 2021. [DOI: 10.1016/b978-0-12-816386-3.00090-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
6
|
Notohamiprodjo S, Treitl KM, Hauke C, Sutter SM, Auweter S, Pfeiffer F, Reiser MF, Hellbach K. Imaging characteristics of intravascular spherical contrast agents for grating-based x-ray dark-field imaging – effects of concentrations, spherical sizes and applied voltage. Sci Rep 2020; 10:9405. [PMID: 32523085 PMCID: PMC7287139 DOI: 10.1038/s41598-020-66395-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2020] [Accepted: 05/14/2020] [Indexed: 11/09/2022] Open
Abstract
AbstractThis study investigates the x-ray scattering characteristics of microsphere particles in x-ray-grating-based interferometric imaging at different concentrations, bubble sizes and tube voltages (kV). Attenuation (ATI), dark-field (DFI) and phase-contrast (PCI) images were acquired. Signal-to-noise (SNR) and contrast-to-noise ratios with water (CNRw) and air as reference (CNRa) were determined. In all modalities, a linear relationship between SNR and microbubbles concentration, respectively, microsphere size was found. A significant gain of SNR was found when varying kV. SNR was significantly higher in DFI and PCI than ATI. The highest gain of SNR was shown at 60 kV for all media in ATI and DFI, at 80 kV for PCI. SNR for all media was significantly higher compared to air and was slightly lower compared to water. A linear relationship was found between CNRa, CNRw, concentration and size. With increasing concentration and decreasing size, CNRa and CNRw increased in DFI, but decreased in PCI. Best CNRa and CNRw was found at specific combination of kV and concentration/size. Highest average CNRa and CNRw was found for microspheres in ATI and PCI, for microbubbles in DFI. Microspheres are a promising contrast-media for grating-based-interferometry, if kV, microsphere size and concentration are appropriately combined.
Collapse
|
7
|
Stride E, Segers T, Lajoinie G, Cherkaoui S, Bettinger T, Versluis M, Borden M. Microbubble Agents: New Directions. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:1326-1343. [PMID: 32169397 DOI: 10.1016/j.ultrasmedbio.2020.01.027] [Citation(s) in RCA: 99] [Impact Index Per Article: 24.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Revised: 01/09/2020] [Accepted: 01/26/2020] [Indexed: 05/24/2023]
Abstract
Microbubble ultrasound contrast agents have now been in use for several decades and their safety and efficacy in a wide range of diagnostic applications have been well established. Recent progress in imaging technology is facilitating exciting developments in techniques such as molecular, 3-D and super resolution imaging and new agents are now being developed to meet their specific requirements. In parallel, there have been significant advances in the therapeutic applications of microbubbles, with recent clinical trials demonstrating drug delivery across the blood-brain barrier and into solid tumours. New agents are similarly being tailored toward these applications, including nanoscale microbubble precursors offering superior circulation times and tissue penetration. The development of novel agents does, however, present several challenges, particularly regarding the regulatory framework. This article reviews the developments in agents for diagnostic, therapeutic and "theranostic" applications; novel manufacturing techniques; and the opportunities and challenges for their commercial and clinical translation.
Collapse
Affiliation(s)
- Eleanor Stride
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, UK.
| | - Tim Segers
- Physics of Fluids Group, Technical Medical (TechMed) Centre, MESA+ Institute for Nanotechnology, University of Twente, The Netherlands
| | - Guillaume Lajoinie
- Physics of Fluids Group, Technical Medical (TechMed) Centre, MESA+ Institute for Nanotechnology, University of Twente, The Netherlands
| | - Samir Cherkaoui
- Bracco Suisse SA - Business Unit Imaging, Global R&D, Plan-les-Ouates, Switzerland
| | - Thierry Bettinger
- Bracco Suisse SA - Business Unit Imaging, Global R&D, Plan-les-Ouates, Switzerland
| | - Michel Versluis
- Physics of Fluids Group, Technical Medical (TechMed) Centre, MESA+ Institute for Nanotechnology, University of Twente, The Netherlands
| | - Mark Borden
- Mechanical Engineering Department, University of Colorado, Boulder, CO, USA
| |
Collapse
|
8
|
Buchanan I, Mittone A, Bravin A, Diemoz P, Endrizzi M, Olivo A. Simplified retrieval method for Edge Illumination X-ray phase contrast imaging allowing multi-modal imaging with fewer input frames. OPTICS EXPRESS 2020; 28:11597-11608. [PMID: 32403667 DOI: 10.1364/oe.372312] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Accepted: 02/28/2020] [Indexed: 05/23/2023]
Abstract
We present data from an implementation of Edge Illumination (EI) that uses a detector aperture designed for increasing dynamic range, suitable for clinically relevant X-ray energies and demonstrated here using synchrotron radiation. By utilising a sufficiently large crosstalk between pixels, this implementation enables single-scan imaging for phase and absorption, and double-scan for phase, absorption and dark field imaging. The presence of the detector mask enables a direct comparison between conventional EI and beam tracking (BT), which we conduct through Monte Carlo and analytical modelling in the case of a single-scan being used for the retrieval of all three contrasts. In the present case, where the X-ray beam width is comparable to the pixel size, we provide an analysis on best-positioning of the beam on the detector for accurate signal retrieval. Further, we demonstrate an application of this method by distinguishing different concentrations of microbubbles via their dark field signals at high energy using an EI system.
Collapse
|
9
|
Tavakoli Taba S, Baran P, Nesterets YI, Pacile S, Wienbeck S, Dullin C, Pavlov K, Maksimenko A, Lockie D, Mayo SC, Quiney HM, Dreossi D, Arfelli F, Tromba G, Lewis S, Gureyev TE, Brennan PC. Comparison of propagation-based CT using synchrotron radiation and conventional cone-beam CT for breast imaging. Eur Radiol 2020; 30:2740-2750. [DOI: 10.1007/s00330-019-06567-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Revised: 10/29/2019] [Accepted: 10/31/2019] [Indexed: 01/08/2023]
|
10
|
Kang RK, Mishr N, Rai VK. Guar Gum Micro-particles for Targeted Co-delivery of Doxorubicin and Metformin HCL for Improved Specificity and Efficacy Against Colon Cancer: In Vitro and In Vivo Studies. AAPS PharmSciTech 2020; 21:48. [PMID: 31900731 DOI: 10.1208/s12249-019-1589-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Accepted: 11/20/2019] [Indexed: 01/05/2023] Open
Abstract
Doxorubicin and Metformin HCL is a known chemotherapeutic combination that wipes out tumors and prevents their recurrence. However, limited site specificity confines its application. Here we report Doxorubicin and Metformin HCL-loaded guar gum micro-particles prepared by emulsification cum-solidification method. Developed micro-particles were characterized as spherical shape particles with smooth surface and micro size diameter. Encapsulation of drugs in combination was confirmed by their characteristic functional groups (FT-IR), change in phase transition temperature (DSC) and X-ray diffraction pattern (XRD). Particles were observed to be stable at 25 and 5°C. The in vitro Doxorubicin and Metformin HCL release study in simulated gastric (SGF), intestinal (SIF) and colonic fluid (SCF) confirms restricted release in SGF (9.3 and 9.6%, respectively, in 2 h) and SIF (10.8 and 14.7%, respectively, in the next 3 h) and highest release in SCF (about 68 and 73.3%, respectively) in colon. Developed micro-particles showed 78% recovery in tumor volume and considerable improvement in histological changes. X-ray images confirmed good target ability of micro-particles to colon. In conclusion, the specially designed, stable micro-particles are able to target drug combination to colon and improve efficacy by ensuring maximum drug release in colon as compared with Doxorubicin and Metformin HCL combination.
Collapse
|
11
|
Tang R, Yan F, Yang GY, Chen KM. Microbubbles containing gadolinium as contrast agents for both phase contrast and magnetic resonance imaging. JOURNAL OF SYNCHROTRON RADIATION 2018; 25:560-564. [PMID: 29488937 DOI: 10.1107/s1600577517017404] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2017] [Accepted: 12/04/2017] [Indexed: 06/08/2023]
Abstract
Portal vein imaging is an important method for investigating portal venous disorders. However, the diagnostic requirements are not usually satisfied when using single imaging techniques. Diagnostic accuracy can be improved by combining different imaging techniques. Contrast agents that can be used for combined imaging modalities are needed. In this study, the feasibility of using microbubbles containing gadolinium (MCG) as contrast agents for both phase contrast imaging (PCI) and magnetic resonance imaging (MRI) are investigated. MCG were made by encapsulating sulfur hexafluoride (SF6) gas with gadolinium and lyophilized powder. Absorption contrast imaging (ACI) and PCI of MCG were performed and compared in vitro. MCG were injected into the main portal trunk of living rats. PCI and MRI were performed at 2 min and 10 min after MCG injection, respectively. PCI exploited the differences in the refractive index and visibly showed the MCG, which were not detectable by ACI. PCI could facilitate clear revelation of the MCG-infused portal veins. The diameter of the portal veins could be determined by the largest MCG in the same portal vein. The minimum diameter of clearly detected portal veins was about 300 µm by MRI. These results indicate that MCG could enhance both PCI and MRI for imaging portal veins. The detection sensitivity of PCI and MRI could compensate for each other when using MCG contrast agents for animals.
Collapse
Affiliation(s)
- Rongbiao Tang
- Department of Radiology. Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, People's Republic of China
| | - Fuhua Yan
- Department of Radiology. Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, People's Republic of China
| | - Guo Yuan Yang
- Neuroscience and Neuroengineering Center, Med-X Research Institute, Shanghai Jiao Tong University, Shanghai 200030, People's Republic of China
| | - Ke Min Chen
- Department of Radiology. Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, People's Republic of China
| |
Collapse
|
12
|
Implementation of a Talbot-Lau interferometer in a clinical-like c-arm setup: A feasibility study. Sci Rep 2018; 8:2325. [PMID: 29396417 PMCID: PMC5797080 DOI: 10.1038/s41598-018-19482-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2017] [Accepted: 01/02/2018] [Indexed: 02/07/2023] Open
Abstract
X-ray grating-based phase-contrast imaging has raised interest regarding a variety of potential clinical applications, whereas the method is feasible using a medical x-ray tube. Yet, the transition towards a clinical setup remains challenging due to the requirement of mechanical robustness of the interferometer and high demands applying to medical equipment in clinical use. We demonstrate the successful implementation of a Talbot-Lau interferometer in an interventional c-arm setup. The consequence of vibrations induced by the rotating anode of the tube is discussed and the prototype is shown to provide a visibility of 21.4% at a tube voltage of 60 kV despite the vibrations. Regarding clinical application, the prototype is mainly set back due to the limited size of the field of view covering an area of 17 mm × 46 mm. A c-arm offers the possibility to change the optical axis according to the requirements of the medical examination. We provide a method to correct for artifacts that result from the angulation of the c-arm. Finally, the images of a series of measurements with the c-arm in different angulated positions are shown. Thereby, it is sufficient to perform a single reference measurement in parking position that is valid for the complete series despite angulation.
Collapse
|
13
|
Abstract
Unlike conventional x-ray attenuation one of the advantages of phase contrast x-ray imaging is its capability of extracting useful physical properties of the sample. In particular the possibility to obtain information from small angle scattering about unresolvable structures with sub-pixel resolution sensitivity has drawn attention for both medical and material science applications. We report on a novel algorithm for the analyzer based x-ray phase contrast imaging modality, which allows the robust separation of absorption, refraction and scattering effects from three measured x-ray images. This analytical approach is based on a simple Gaussian description of the analyzer transmission function and this method is capable of retrieving refraction and small angle scattering angles in the full angular range typical of biological samples. After a validation of the algorithm with a simulation code, which demonstrated the potential of this highly sensitive method, we have applied this theoretical framework to experimental data on a phantom and biological tissues obtained with synchrotron radiation. Owing to its extended angular acceptance range the algorithm allows precise assessment of local scattering distributions at biocompatible radiation doses, which in turn might yield a quantitative characterization tool with sufficient structural sensitivity on a submicron length scale.
Collapse
|
14
|
Wu D, Wong MD, Li Y, Fajardo L, Zheng B, Wu X, Liu H. Quantitative investigation of the edge enhancement in in-line phase contrast projections and tomosynthesis provided by distributing microbubbles on the interface between two tissues: a phantom study. Phys Med Biol 2017; 62:9357-9376. [PMID: 29161236 PMCID: PMC5731655 DOI: 10.1088/1361-6560/aa9548] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The objective of this study was to quantitatively investigate the ability to distribute microbubbles along the interface between two tissues, in an effort to improve the edge and/or boundary features in phase contrast imaging. The experiments were conducted by employing a custom designed tissue simulating phantom, which also simulated a clinical condition where the ligand-targeted microbubbles are self-aggregated on the endothelium of blood vessels surrounding malignant cells. Four different concentrations of microbubble suspensions were injected into the phantom: 0%, 0.1%, 0.2%, and 0.4%. A time delay of 5 min was implemented before image acquisition to allow the microbubbles to become distributed at the interface between the acrylic and the cavity simulating a blood vessel segment. For comparison purposes, images were acquired using three system configurations for both projection and tomosynthesis imaging with a fixed radiation dose delivery: conventional low-energy contact mode, low-energy in-line phase contrast and high-energy in-line phase contrast. The resultant images illustrate the edge feature enhancements in the in-line phase contrast imaging mode when the microbubble concentration is extremely low. The quantitative edge-enhancement-to-noise ratio calculations not only agree with the direct image observations, but also indicate that the edge feature enhancement can be improved by increasing the microbubble concentration. In addition, high-energy in-line phase contrast imaging provided better performance in detecting low-concentration microbubble distributions.
Collapse
Affiliation(s)
- Di Wu
- School of Electrical and Computer Engineering, University of Oklahoma, 110 West Boyd Street, Norman, OK 73019, United States of America
| | | | | | | | | | | | | |
Collapse
|
15
|
Tang R, Yan F, Yang GY, Chen KM. Phase contrast imaging of preclinical portal vein embolization with CO 2 microbubbles. JOURNAL OF SYNCHROTRON RADIATION 2017; 24:1260-1264. [PMID: 29091069 DOI: 10.1107/s1600577517014072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2017] [Accepted: 09/29/2017] [Indexed: 06/07/2023]
Abstract
Preoperative portal vein embolization (PVE) is employed clinically to avoid postoperative liver insufficiency. Animal models are usually used to study PVE in terms of mechanisms and pathophysiological changes. PVE is formerly monitored by conventional absorption contrast imaging (ACI) with iodine contrast agent. However, the side effects induced by iodine can give rise to animal damage and death. In this study, the feasibility of using phase contrast imaging (PCI) to show PVE using homemade CO2 microbubbles in living rats has been investigated. CO2 gas was first formed from the reaction between citric acid and sodium bicarbonate. The CO2 gas was then encapsulated by egg white to fabricate CO2 microbubbles. ACI and PCI of CO2 microbubbles were performed and compared in vitro. An additional increase in contrast was detected in PCI. PCI showed that CO2 microbubbles gradually dissolved over time, and the remaining CO2 microbubbles became larger. By PCI, the CO2 microbubbles were found to have certain stability, suggesting their potential use as embolic agents. CO2 microbubbles were injected into the main portal trunk to perform PVE in living rats. PCI exploited the differences in the refractive index and facilitated clear visualization of the PVE after the injection of CO2 microbubbles. Findings from this study suggest that homemade CO2 microbubbles-based PCI is a novel modality for preclinical PVE research.
Collapse
Affiliation(s)
- Rongbiao Tang
- Department of Radiology, Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, People's Republic of China
| | - Fuhua Yan
- Department of Radiology, Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, People's Republic of China
| | - Guo Yuan Yang
- Neuroscience and Neuroengineering Center, Med-X Research Institute, Shanghai Jiao Tong University School of Medicine, Shanghai 200030, People's Republic of China
| | - Ke Min Chen
- Department of Radiology, Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, People's Republic of China
| |
Collapse
|
16
|
Wu D, Wong MD, Yang K, Yan A, Li Y, Fajardo L, Zheng B, Wu X, Liu H. Using Microbubble as Contrast Agent for High-Energy X-Ray In-line Phase Contrast Imaging: Demonstration and Comparison Study. IEEE Trans Biomed Eng 2017; 65:1117-1123. [PMID: 28829304 DOI: 10.1109/tbme.2017.2741942] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The ability of microbubbles to benefit the imaging quality of high-energy in-line phase contrast as compared with conventional low-energy contact mode radiography was investigated. The study was conducted by comparing in-line phase contrast imaging with conventional contact-mode projection imaging under the same dose delivered to a phantom. A custom-designed phantom was employed to simulate a segment of human blood vessel injected with microbubble suspensions. The microbubbles were suspended in deionized water to obtain different volume concentrations. The area contrast-to-noise ratio (CNR) values corresponding to both imaging methods were measured for different microbubble volume concentrations. The phase contrast images were processed by phase-attenuation duality phase retrieval to preserve the imaging quality. Comparison of the resultant CNR values indicates that the microbubble suspension images deliver a higher CNR than the water-only image, with monotonically increasing trends between the CNR values and microbubble concentrations. Compared to low-energy conventional images of the microbubble suspensions, high-energy in-line phase contrast CNRs are lower at high concentrations and are comparable, even better than, at low concentrations. This result suggests that 1) the performance of copolymer-shell microbubble employed in this study as x-ray contrast agent is constrained by the detective quantum efficiency of the system and the attenuation properties of the shell materials, 2) the phase-attenuation duality phase retrieval method has the potential to preserve image quality for areas with low concentration of microbubbles, and 3) the selection of microbubble products as a phase contrast agent may follow criteria of minimizing the impact of absorption attenuation properties of the shells and maximizing the difference factor of electron densities.
Collapse
|
17
|
Molecular evaluation of thrombosis using X-ray phase contrast imaging with microbubbles targeted to P-selectin in mice. Eur Radiol 2015; 26:3253-61. [PMID: 26628067 DOI: 10.1007/s00330-015-4129-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2015] [Revised: 11/15/2015] [Accepted: 11/19/2015] [Indexed: 10/22/2022]
Abstract
OBJECTIVES X-ray phase contrast imaging (PCI) provides excellent image contrast by utilizing the phase shift. The introduction of microbubbles into tissues can cause a phase shift to make microbubbles visibly identified on PCI. In this study, we assessed the feasibility of targeted microbubble-based PCI for the detection of thrombosis. METHODS The absorption and phase contrast images of P-selectin-targeted microbubbles (MBP) were obtained and compared in vitro. MBP, control IgG-targeted microbubbles (MBC), and unbound microbubbles (MBU) were tested for binding specificity on thrombi expressing P-selectin. MBP were used as molecular PCI probes to evaluate P-selectin expression in a mouse model of arteriovenous shunt thrombosis that was created using PE tubes in the bypass outside of the mouse body. RESULTS PCI clearly showed the microbubbles not viewable via absorption contrast imaging (ACI). In vitro attachment of MBP (91.60 ± 11.63) to thrombi was significantly higher than attachment of MBC (17.80 ± 4.02, P < 0.001) or MBU (9.80 ± 2.59, P < 0.001). In the mouse model of arteriovenous shunt thrombosis, the binding affinity of MBP (15.50 ± 6.25) was significantly greater than that of MBC (0.50 ± 0.84, P < 0.001) or MBU (0.33 ± 0.52, P < 0.001). CONCLUSIONS Our results indicate that molecular PCI may be considered as a novel and promising imaging modality for the investigation of thrombosis. KEY POINTS • Small thrombi are rarely detected by conventional radiography. • Phase contrast imaging (PCI) provides higher contrast and spatial resolution than conventional radiography. • P-selectin targeted microbubbles detected by PCI may suggest early thrombosis.
Collapse
|