1
|
Dong J, Li X, Hou C, Hou J, Huo D. A Novel CRISPR/Cas12a-Mediated Ratiometric Dual-Signal Electrochemical Biosensor for Ultrasensitive and Reliable Detection of Circulating Tumor Deoxyribonucleic Acid. Anal Chem 2024; 96:6930-6939. [PMID: 38652001 DOI: 10.1021/acs.analchem.3c05700] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/25/2024]
Abstract
Circulating tumor DNA (ctDNA) holds great promise as a noninvasive biomarker for cancer diagnosis, treatment, and prognosis. However, the accurate and specific quantification of low-abundance ctDNA in serum remains a significant challenge. This study introduced, for the first time, a novel exponential amplification reaction (EXPAR)-assisted CRISPR/Cas12a-mediated ratiometric dual-signal electrochemical biosensor for ultrasensitive and reliable detection of ctDNA. To implement the dual-signal strategy, a signal unit (ssDNA-MB@Fc/UiO-66-NH2) was prepared, consisting of methylene blue-modified ssDNA as the biogate to encapsulate ferrocene signal molecules within UiO-66-NH2 nanocarriers. The presence of target ctDNA KRAS triggered EXPAR amplification, generating numerous activators for Cas12a activation, resulting in the cleavage of ssDNA-P fully complementary to the ssDNA-MB biogate. Due to the inability to form a rigid structure dsDNA (ssDNA-MB/ssDNA-P), the separation of ssDNA-MB biogate from the UiO-66-NH2 surface was hindered by electrostatic interactions. Consequently, the supernatant collected after centrifugation exhibited either no or only a weak presence of Fc and MB signal molecules. Conversely, in the absence of the target ctDNA, the ssDNA-MB biogate was open, leading to the leakage of Fc signal molecules. This clever ratiometric strategy with Cas12a as the "connector", reflecting the concentration of ctDNA KRAS based on the ratio of the current intensities of the two electroactive signal molecules, enhanced detection sensitivity by at least 60-300 times compared to single-signal strategies. Moreover, this strategy demonstrated satisfactory performance in ctDNA detection in complex human serum, highlighting its potential for cancer diagnosis.
Collapse
Affiliation(s)
- Jiangbo Dong
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Xinyao Li
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Changjun Hou
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China
- Chongqing Key Laboratory of Bio-perception & Intelligent Information Processing, School of Microelectronics and Communication Engineering, Chongqing University, Chongqing 400044, PR China
| | - Jingzhou Hou
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China
- Chongqing Engineering and Technology Research Center of Intelligent Rehabilitation and Eldercare, Chongqing City Management College, Chongqing 401331, PR China
| | - Danqun Huo
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| |
Collapse
|
2
|
Song G, Han H, Ma Z. Anti-Fouling Strategies of Electrochemical Sensors for Tumor Markers. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23115202. [PMID: 37299929 DOI: 10.3390/s23115202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 05/26/2023] [Accepted: 05/27/2023] [Indexed: 06/12/2023]
Abstract
The early detection and prognosis of cancers require sensitive and accurate detection methods; with developments in medicine, electrochemical biosensors have been developed that can meet these clinical needs. However, the composition of biological samples represented by serum is complex; when substances undergo non-specific adsorption to an electrode and cause fouling, the sensitivity and accuracy of the electrochemical sensor are affected. In order to reduce the effects of fouling on electrochemical sensors, a variety of anti-fouling materials and methods have been developed, and enormous progress has been made over the past few decades. Herein, the recent advances in anti-fouling materials and strategies for using electrochemical sensors for tumor markers are reviewed; we focus on new anti-fouling methods that separate the immunorecognition and signal readout platforms.
Collapse
Affiliation(s)
- Ge Song
- Department of Chemistry, Capital Normal University, Beijing 100048, China
| | - Hongliang Han
- Department of Chemistry, Capital Normal University, Beijing 100048, China
| | - Zhanfang Ma
- Department of Chemistry, Capital Normal University, Beijing 100048, China
| |
Collapse
|
3
|
Dong J, Wen L, Yang H, Zhao J, He C, Hu Z, Peng L, Hou C, Huo D. Catalytic Hairpin Assembly-Driven Ratiometric Dual-Signal Electrochemical Biosensor for Ultrasensitive Detection of MicroRNA Based on the Ratios of Fe-MOFs and MB-GA-UiO-66-NH 2. Anal Chem 2022; 94:5846-5855. [PMID: 35380794 DOI: 10.1021/acs.analchem.1c05293] [Citation(s) in RCA: 34] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
In this work, a novel ratio electrochemical biosensing platform based on catalytic hairpin assembly target recovery to trigger dual-signal output was developed for ultrasensitive detection of microRNA (miRNA). To achieve the ratiometric dual-signal strategy, methylene blue (MB), an electrochemical indicator, was ingeniously loaded into the pores of graphene aerogel (GA) and metal-organic framework (MOF) composites with high porosity and large specific surface area, and another electrochemical indicator Fe-MOFs with distinct separation of redox potential was selected as a signal probe. Concretely, with the presence of the target miRNA, the CHA process was initiated and the signal probe was introduced to the electrode surface, producing abundant double-stranded H1-H2@Fe-MOFs-NH2. Then, the measurement and analysis of the prepared ratiometric electrochemical biosensor by differential pulse voltammetry (DPV) showed that the introduction of the target miRNA led to an increase in the oxidation peak signal of Fe-MOFs (+0.8 V) and a decrease in the oxidation peak signal of MB (-0.23 V). Therefore, the peak current ratio of IFe-MOFs/IMB could be employed to accurately reflect the actual concentration of miRNA. Under optimal conditions, the detection limit of the proposed biosensor was down to 50 aM. It was worth noting that the proposed biosensor exhibited excellent detection performance in a complex serum environment and tumor cell lysates, showing great potential in biosensing and clinical diagnosis.
Collapse
Affiliation(s)
- Jiangbo Dong
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, P. R. China
| | - Li Wen
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, P. R. China
| | - Huisi Yang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, P. R. China
| | - Jiaying Zhao
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, P. R. China
| | - Congjuan He
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, P. R. China
| | - Zhikun Hu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, P. R. China
| | - Lan Peng
- Chongqing Medical and Pharmaceutical College Basic Department, Chongqing 401331, P. R. China
| | - Changjun Hou
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, P. R. China.,National Facility for Translational Medicine (Shanghai), Shanghai 200240, P. R. China
| | - Danqun Huo
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, P. R. China.,Chongqing Key Laboratory of Bio-perception & Intelligent Information Processing, School of Microelectronics and Communication Engineering, Chongqing University, Chongqing 400044, P. R. China
| |
Collapse
|
4
|
Rao H, Li J, Luo M, Zhang K, Gou H, Liu H, Xue Z. A label-free and modification-free ratiometric electrochemical strategy for enhanced natural enzyme detection using a bare electrode and nanozymes system. Anal Bioanal Chem 2022; 414:2991-3003. [PMID: 35106612 DOI: 10.1007/s00216-022-03932-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 01/22/2022] [Accepted: 01/26/2022] [Indexed: 01/05/2023]
Abstract
Ratiometric electrochemical assays have been demonstrated to be more sensitive and selective in various sensing events, mainly due to their affordable built-in correction and good self-reference capability. But it is known that complicated modification and labeling operations usually are necessary for the construction of ratiometric electrochemical assays, therefore is a hot and important issue needing consideration carefully. We herein report a new yet simple bare electrode-based ratiometric electrochemical bioassay to achieve sensitive and selective analysis of alkaline phosphatase (ALP), using a liquid phase system that contains CoOOH nanozymes and commercially available indicator substrate. This proposed bioassay works based on the ratiometric change of dual electrochemical signals, arising from an exclusive target ALP-triggered hydrolysis of electrochemical substrate p-nitrophenyl phosphate (PNPP). In this design, the two hydrolyzed products of electrochemically active p-nitrophenol (PNP) and electrochemically inactive phosphate anion (PO43-) are responsible together for the ratiometric electrochemical analysis of ALP. PNP exhibits a straightforward current response toward ALP content; however, PO43- cannot show a direct electrochemical signal thus is rationally designed to offer an alternative response by linking it with the specific CoOOH nanozyme-catalyzed reaction of 3,3',5,5'-tetramethylbenzidine (TMB) and H2O2, in which the nanozyme-catalyzed product oxTMB shows a direct reduction current at the GCE, and significantly decreases with increasing PO43- species due to the good inhibition of PO43- toward CoOOH nanozyme activity. As a result, a ratiometric electrochemical strategy for ALP analysis with a low limit of detection of 0.366 U/L (S/N = 3) was successfully achieved by integrating the above direct and indirect dual electrochemical responses. This developed bioassay can allow the quantitative diagnosis of ALP activity especially with a label-free and modification-free merit, therefore paving the way for simple, convenient, and portable electroanalytical tools in biosensing design and application.
Collapse
Affiliation(s)
- Honghong Rao
- College of Chemistry & Engineering, Lanzhou City University, Lanzhou, 730070, China.
| | - Jianying Li
- College of Chemistry & Engineering, Lanzhou City University, Lanzhou, 730070, China.,Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou, 730070, China
| | - Mingyue Luo
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou, 730070, China
| | - Kehui Zhang
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou, 730070, China
| | - Hao Gou
- College of Chemistry & Engineering, Lanzhou City University, Lanzhou, 730070, China
| | - Haixia Liu
- College of Chemistry & Engineering, Lanzhou City University, Lanzhou, 730070, China
| | - Zhonghua Xue
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou, 730070, China
| |
Collapse
|
5
|
Feng J, Chu C, Ma Z. Electrochemical Signal Substance for Multiplexed Immunosensing Interface Construction: A Mini Review. Molecules 2022; 27:267. [PMID: 35011499 PMCID: PMC8746521 DOI: 10.3390/molecules27010267] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 12/23/2021] [Accepted: 12/30/2021] [Indexed: 11/17/2022] Open
Abstract
Appropriate labeling method of signal substance is necessary for the construction of multiplexed electrochemical immunosensing interface to enhance the specificity for the diagnosis of cancer. So far, various electrochemical substances, including organic molecules, metal ions, metal nanoparticles, Prussian blue, and other methods for an electrochemical signal generation have been successfully applied in multiplexed biosensor designing. However, few works have been reported on the summary of electrochemical signal substance applied in constructing multiplexed immunosensing interface. Herein, according to the classification of labeled electrochemical signal substance, this review has summarized the recent state-of-art development for the designing of electrochemical immunosensing interface for simultaneous detection of multiple tumor markers. After that, the conclusion and prospects for future applications of electrochemical signal substances in multiplexed immunosensors are also discussed. The current review can provide a comprehensive summary of signal substance selection for workers researched in electrochemical sensors, and further, make contributions for the designing of multiplexed electrochemical immunosensing interface with well signal.
Collapse
Affiliation(s)
| | | | - Zhanfang Ma
- Department of Chemistry, Capital Normal University, Beijing 100048, China; (J.F.); (C.C.)
| |
Collapse
|
6
|
Phetsang S, Khwannimit D, Rattanakit P, Chanlek N, Kidkhunthod P, Mungkornasawakul P, Jakmunee J, Ounnunkad K. A Redox Cu(II)-Graphene Oxide Modified Screen Printed Carbon Electrode as a Cost-Effective and Versatile Sensing Platform for Electrochemical Label-Free Immunosensor and Non-enzymatic Glucose Sensor. Front Chem 2021; 9:671173. [PMID: 34095085 PMCID: PMC8172615 DOI: 10.3389/fchem.2021.671173] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Accepted: 04/14/2021] [Indexed: 11/24/2022] Open
Abstract
A novel copper (II) ions [Cu(II)]-graphene oxide (GO) nanocomplex-modified screen-printed carbon electrode (SPCE) is successfully developed as a versatile electrochemical platform for construction of sensors without an additionally external redox probe. A simple strategy to prepare the redox GO-modified SPCE is described. Such redox GO based on adsorbed Cu(II) is prepared by incubation of GO-modified SPCE in the Cu(II) solution. This work demonstrates the fabrications of two kinds of electrochemical sensors, i.e., a new label-free electrochemical immunosensor and non-enzymatic sensor for detections of immunoglobulin G (IgG) and glucose, respectively. Our immunosensor based on square-wave voltammetry (SWV) of the redox GO-modified electrode shows the linearity in a dynamic range of 1.0-500 pg.mL-1 with a limit of detection (LOD) of 0.20 pg.mL-1 for the detection of IgG while non-enzymatic sensor reveals two dynamic ranges of 0.10-1.00 mM (sensitivity = 36.31 μA.mM-1.cm-2) and 1.00-12.50 mM (sensitivity = 3.85 μA.mM-1.cm-2) with a LOD value of 0.12 mM. The novel redox Cu(II)-GO composite electrode is a promising candidate for clinical research and diagnosis.
Collapse
Affiliation(s)
- Sopit Phetsang
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- National Institute of Technology, Nagaoka College, Niigata, Japan
| | - Duangruedee Khwannimit
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- Division of Chemistry, School of Science, Walailak University, Nakhon Si Thammarat, Thailand
| | - Parawee Rattanakit
- Division of Chemistry, School of Science, Walailak University, Nakhon Si Thammarat, Thailand
| | - Narong Chanlek
- Synchrotron Light Research Institute (Public Organization), Nakhon Ratchasima, Thailand
| | - Pinit Kidkhunthod
- Synchrotron Light Research Institute (Public Organization), Nakhon Ratchasima, Thailand
| | - Pitchaya Mungkornasawakul
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- Environmental Science Research Center, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
| | - Jaroon Jakmunee
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- Research Center on Chemistry for Development of Health Promoting Products from Northern Resources, Chiang Mai University, Chiang Mai, Thailand
| | - Kontad Ounnunkad
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- Research Center on Chemistry for Development of Health Promoting Products from Northern Resources, Chiang Mai University, Chiang Mai, Thailand
- Center of Excellence in Materials Science and Technology, Chiang Mai University, Chiang Mai, Thailand
| |
Collapse
|
7
|
Spring SA, Goggins S, Frost CG. Ratiometric Electrochemistry: Improving the Robustness, Reproducibility and Reliability of Biosensors. Molecules 2021; 26:2130. [PMID: 33917231 PMCID: PMC8068091 DOI: 10.3390/molecules26082130] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 04/01/2021] [Accepted: 04/02/2021] [Indexed: 12/21/2022] Open
Abstract
Electrochemical biosensors are an increasingly attractive option for the development of a novel analyte detection method, especially when integration within a point-of-use device is the overall objective. In this context, accuracy and sensitivity are not compromised when working with opaque samples as the electrical readout signal can be directly read by a device without the need for any signal transduction. However, electrochemical detection can be susceptible to substantial signal drift and increased signal error. This is most apparent when analysing complex mixtures and when using small, single-use, screen-printed electrodes. Over recent years, analytical scientists have taken inspiration from self-referencing ratiometric fluorescence methods to counteract these problems and have begun to develop ratiometric electrochemical protocols to improve sensor accuracy and reliability. This review will provide coverage of key developments in ratiometric electrochemical (bio)sensors, highlighting innovative assay design, and the experiments performed that challenge assay robustness and reliability.
Collapse
Affiliation(s)
- Sam A. Spring
- Department of Chemistry, University of Bath, Claverton Down, Bath BA2 7AY, UK;
| | - Sean Goggins
- Bio-Techne (Tocris), The Watkins Building, Atlantic Road, Avonmouth, Bristol BS11 9QD, UK;
| | | |
Collapse
|
8
|
Cho IH, Kim DH, Park S. Electrochemical biosensors: perspective on functional nanomaterials for on-site analysis. Biomater Res 2020; 24:6. [PMID: 32042441 PMCID: PMC7001310 DOI: 10.1186/s40824-019-0181-y] [Citation(s) in RCA: 209] [Impact Index Per Article: 52.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Accepted: 12/29/2019] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND The electrochemical biosensor is one of the typical sensing devices based on transducing the biochemical events to electrical signals. In this type of sensor, an electrode is a key component that is employed as a solid support for immobilization of biomolecules and electron movement. Thanks to numerous nanomaterials that possess the large surface area, synergic effects are enabled by improving loading capacity and the mass transport of reactants for achieving high performance in terms of analytical sensitivity. MAIN BODY We categorized the current electrochemical biosensors into two groups, carbon-based (carbon nanotubes and graphene) and non-carbon-based nanomaterials (metallic and silica nanoparticles, nanowire, and indium tin oxide, organic materials). The carbon allotropes can be employed as an electrode and supporting scaffolds due to their large active surface area as well as an effective electron transfer rate. We also discussed the non-carbon nanomaterials that are used as alternative supporting components of the electrode for improving the electrochemical properties of biosensors. CONCLUSION Although several functional nanomaterials have provided the innovative solid substrate for high performances, developing on-site version of biosensor that meets enough sensitivity along with high reproducibility still remains a challenge. In particular, the matrix interference from real samples which seriously affects the biomolecular interaction still remains the most critical issues that need to be solved for practical aspect in the electrochemical biosensor.
Collapse
Affiliation(s)
- Il-Hoon Cho
- Department of Biomedical Laboratory Science, College of Health Science, Eulji University, Seongnam, 13135 Republic of Korea
| | - Dong Hyung Kim
- Division of Advanced Instrumentation Institute, Korea Research Institute of Standards and Science (KRISS), 267 Gajeong-Ro, Yuseong-Gu, Daejeon, 34113 Republic of Korea
| | - Sangsoo Park
- Department of Biomedical Engineering, College of Health Science, Eulji University, Seongnam, 13135 Republic of Korea
| |
Collapse
|
9
|
A new ratiometric electrochemical immunoassay for reliable detection of nuclear matrix protein 22. Anal Chim Acta 2019; 1086:103-109. [DOI: 10.1016/j.aca.2019.08.017] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2019] [Revised: 08/08/2019] [Accepted: 08/09/2019] [Indexed: 11/22/2022]
|
10
|
Wang X, Liu G, Qi Y, Yuan Y, Gao J, Luo X, Yang T. Embedded Au Nanoparticles-Based Ratiometric Electrochemical Sensing Strategy for Sensitive and Reliable Detection of Copper Ions. Anal Chem 2019; 91:12006-12013. [PMID: 31433623 DOI: 10.1021/acs.analchem.9b02945] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
The ratiometric method allows the measurement of ratio changes between two signals, which can reduce the detection signal fluctuations caused by distinct background conditions and greatly improve the reproducibility and reliability of detection. However, in contrast with the emerging dual excitation or dual emission dyes applied in ratiometric luminescence measurement, only a few internal reference probes have been exploited for ratiometric electrochemical detection. In this paper, a gold nanoparticles@carbonized resin nanospheres composite with thermally reduced graphene oxide as scaffold (AuNPs@CRS-TrGNO) has been fabricated, and the AuNPs embedded in the CRS were first used as an internal reference probe for ratiometric electrochemical detection. The detachment and aggregation of AuNPs is suppressed by embedding in the CRS, so its redox signal is very stable, which provides feasibility for ratiometric detection. Moreover, the embedment of AuNPs, carbonization of resin spheres, and hybridization with TrGNO all have played positive roles in improving the charge transfer rate, which leads to excellent electrochemical performance of the composite. Based on these characteristics of the AuNPs@CRS-TrGNO, a new ratiometric electrochemical detection platform was constructed, and copper ions (Cu2+) in simulated seawater were successfully detected. This ratiometric method has the advantages of simple design and convenient operation, and obviously it improves the reproducibility and reliability of the electrochemical sensor.
Collapse
Affiliation(s)
- Xinxing Wang
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; Shandong Key Laboratory of Biochemical Analysis; Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong; Key Laboratory of Eco-chemical Engineering; College of Chemistry and Molecular Engineering , Qingdao University of Science and Technology , Qingdao 266042 , China
| | - Guangmao Liu
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; Shandong Key Laboratory of Biochemical Analysis; Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong; Key Laboratory of Eco-chemical Engineering; College of Chemistry and Molecular Engineering , Qingdao University of Science and Technology , Qingdao 266042 , China
| | - Youxiao Qi
- College of Environment and Safety Engineering , Qingdao University of Science and Technology , Qingdao 266042 , China
| | - Yue Yuan
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; Shandong Key Laboratory of Biochemical Analysis; Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong; Key Laboratory of Eco-chemical Engineering; College of Chemistry and Molecular Engineering , Qingdao University of Science and Technology , Qingdao 266042 , China
| | - Jian Gao
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; Shandong Key Laboratory of Biochemical Analysis; Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong; Key Laboratory of Eco-chemical Engineering; College of Chemistry and Molecular Engineering , Qingdao University of Science and Technology , Qingdao 266042 , China
| | - Xiliang Luo
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE; Shandong Key Laboratory of Biochemical Analysis; Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong; Key Laboratory of Eco-chemical Engineering; College of Chemistry and Molecular Engineering , Qingdao University of Science and Technology , Qingdao 266042 , China
| | - Tao Yang
- School of Chemical Engineering and Technology , Sun Yat-Sen University , Zhuhai 519082 , China
| |
Collapse
|
11
|
Yu L, Cui X, Li H, Lu J, Kang Q, Shen D. A ratiometric electrochemical sensor for multiplex detection of cancer biomarkers using bismuth as an internal reference and metal sulfide nanoparticles as signal tags. Analyst 2019; 144:4073-4080. [PMID: 31165805 DOI: 10.1039/c9an00775j] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Ratiometric electrochemical sensors can provide a relatively accurate analysis of target analytes due to their self-calibration function. Herein, we report a simple ratiometric strategy for achieving the electrochemical detection of Cd(ii), Hg(ii), Pb(ii) and Zn(ii), as well as multiple cancer biomarkers by using metal sulfide nanoparticles as signal tags. A conductive polymer film of poly(2-amino terephthalic acid) (ATA) was electrochemically produced on a glassy carbon electrode (GCE) and doped with carbon nanotubes (CNTs) and mercaptosuccinic acid (MSA). Using Bi(iii) as an enhancer and internal reference in anodic stripping voltammetry, the MSA-CNT-ATA/GCE exhibited sensitive and distinguishable voltammetric responses to Cd(ii), Hg(ii), Pb(ii) and Zn(ii), with detection limits of 0.13, 0.49, 0.16 and 0.089 μg L-1, respectively. By using CdS, HgS, PbS and ZnS labeled secondary antibodies as the signal tags, alpha-fetoprotein, carbohydrate antigen 19-9, carbohydrate antigen 125, and carcinoembryonic antigen were determined simultaneously according to the amounts of metal sulfide in the sandwich-type complexes, with detection limits of 0.11 pg mL-1, 0.68 mU mL-1, 1.4 mU mL-1 and 0.23 pg mL-1, respectively. This ratiometric approach has a wide scope in the electrochemical detection of heavy metal ions as well as immunoassays with metal ions serving as signal tags.
Collapse
Affiliation(s)
- Lei Yu
- College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of MoleCular and Nano Probes, Ministry of Education, Shandong Normal University, Jinan 250014, P. R. China.
| | | | | | | | | | | |
Collapse
|
12
|
Dou B, Li J, Jiang B, Yuan R, Xiang Y. Electrochemical screening of single nucleotide polymorphisms with significantly enhanced discrimination factor by an amplified ratiometric sensor. Anal Chim Acta 2018; 1038:166-172. [PMID: 30278899 DOI: 10.1016/j.aca.2018.07.027] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2017] [Revised: 06/14/2018] [Accepted: 07/10/2018] [Indexed: 01/12/2023]
Abstract
The detection of single nucleotide polymorphisms (SNPs) is of great clinical significance to the diagnosis of various genetic diseases and cancers. In this work, the development of an ultrasensitive ratiometric electrochemical sensor for screening SNP with a significantly enhanced discrimination factor is reported. The ferrocene (Fc) and methylene blue (MB) dual-tagged triple helix complex (THC) probes are self-assembled on the gold electrode to construct the sensing interface. The addition of the mutant p53 gene causes the disassembly of the THC probes with the release of the Fc-tagged sequence and the folding of the MB-labeled sequence into a hairpin structure, causing the change in the current response ratio of MB to Fc for monitoring the mutant p53 gene. Such ratio is dramatically enhanced by the toehold-mediated displacement reaction-assisted target recycling amplification with the presence of an assistance hairpin sequence. With the significant signal amplification and the advantageous specificity of the THC probes, sub-femtomolar detection limit and a highly enhanced SNP discrimination factor for the mutant p53 gene can be obtained. Besides, the proof-of-demonstration application of the sensor for diluted real samples has been verified, offering such sensor new opportunities for monitoring various genetic related diseases.
Collapse
Affiliation(s)
- Baoting Dou
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry, Ministry of Education, School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China
| | - Jin Li
- School of Chemistry and Chemical Engineering, Chongqing University of Technology, Chongqing 400054, PR China
| | - Bingying Jiang
- School of Chemistry and Chemical Engineering, Chongqing University of Technology, Chongqing 400054, PR China.
| | - Ruo Yuan
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry, Ministry of Education, School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China
| | - Yun Xiang
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry, Ministry of Education, School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China.
| |
Collapse
|
13
|
Tang Z, Ma Z. Multiple functional strategies for amplifying sensitivity of amperometric immunoassay for tumor markers: A review. Biosens Bioelectron 2017; 98:100-112. [DOI: 10.1016/j.bios.2017.06.041] [Citation(s) in RCA: 69] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2017] [Revised: 06/16/2017] [Accepted: 06/19/2017] [Indexed: 02/07/2023]
|
14
|
Tang Z, Fu Y, Ma Z. Multiple signal amplification strategies for ultrasensitive label-free electrochemical immunoassay for carbohydrate antigen 24-2 based on redox hydrogel. Biosens Bioelectron 2016; 91:299-305. [PMID: 28033559 DOI: 10.1016/j.bios.2016.12.049] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Revised: 12/21/2016] [Accepted: 12/21/2016] [Indexed: 12/12/2022]
Abstract
In this work, multiple signal amplification strategies for ultrasensitive label-free electrochemical immunoassay for carbohydrate antigen 24-2 (CA242) were developed using redox sodium alginate-Pb2+-graphene oxide (SA-Pb2+-GO) hydrogel. The SA-Pb2+-GO hydrogel was synthesised by simply mixing SA, GO, and Pb2+ and then implemented as a novel redox species with a strong current signal at -0.46V (vs. Ag/AgCl). After the three-dimensional and porous SA-Pb2+-GO hydrogel was in situ generated on a glassy carbon electrode (GCE), chitosan was adsorbed on the obtained electrode to further enrich Pb2+. When chitosan-Pb2+/SA-Pb2+-GO/GCE was incubated with anti-CA242 using glutaraldehyde and blocked by bovine serum albumin, the immunoassay platform for CA242 was obtained. Owing to the addition of GO, the obtained conductive SA-GO/GCE was beneficial for signal amplification. After incubating SA-GO/GCE with excessive amounts of Pb2+, the resistance of SA-Pb2+-GO/GCE further decreased and a strong redox signal was obtained. The chitosan fixed by electrostatic adsorption resulted in further adsorption of Pb2+, behaving as further amplifying the signal and improving conductivity. In this case, multiple signal amplification strategies were involved in the proposed immunosensor for the ultrasensitive detection of CA242. Under the optimal conditions, the proposed immunosensor exhibited a wide linear range from 0.005UmL-1 to 500UmL-1 with an ultralow detection limit of 0.067mUmL-1. In comparison to previous works, the sensitivity of this method was 32.98μA (log10CCA242)-1, which was a five-fold increase from the previous works.
Collapse
Affiliation(s)
- Zhongxue Tang
- Department of Chemistry, Capital Normal University, Beijing 100048, China
| | - Yuanyuan Fu
- Department of Chemistry, Capital Normal University, Beijing 100048, China
| | - Zhanfang Ma
- Department of Chemistry, Capital Normal University, Beijing 100048, China.
| |
Collapse
|