1
|
Robertson E, Boulanger P, Kwan P, Louie G, Aalto D. Improving Cranial Vault Remodeling for Unilateral Coronal Craniosynostosis-Introducing Automated Surgical Planning. Craniomaxillofac Trauma Reconstr 2024; 17:203-213. [PMID: 39377079 PMCID: PMC11456203 DOI: 10.1177/19433875231178912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/09/2024] Open
Abstract
Study Design Cranial vault remodeling (CVR) for unicoronal synostosis is challenging due to the asymmetric nature of the deformity. Computer-automated surgical planning has demonstrated success in reducing the subjectivity of decision making in CVR in symmetric subtypes. This proof of concept study presents a novel method using Boolean functions and image registration to automatically suggest surgical steps in asymmetric craniosynostosis. Objective The objective of this study is to introduce automated surgical planning into a CVR virtual workflow for an asymmetric craniosynostosis subtype. Methods Virtual workflows were developed using Geomagic Freeform Plus software. Hausdorff distances and color maps were used to compare reconstruction models to the preoperative model and a control skull. Reconstruction models were rated as high or low performing based on similarity to the normal skull and the amount of advancement of the frontal bone (FB) and supra-orbital bar (SOB). Fifteen partially and fully automated workflow iterations were carried out. Results FB and SOB advancement ranged from 3.08 to 10.48 mm, and -1.75 to 7.78 mm, respectively. Regarding distance from a normal skull, models ranged from .85 to 5.49 mm at the FB and 5.40 to 10.84 mm at the SOB. An advancement of 8.43 mm at the FB and 7.73 mm at the SOB was achieved in the highest performing model, and it differed to a comparative normal skull by .02 mm at the FB and .48 mm at the SOB. Conclusions This is the first known attempt at developing an automated virtual surgical workflow for CVR in asymmetric craniosynostosis. Key regions of interest were outlined using Boolean operations, and surgical steps were suggested using image registration. These techniques improved post-operative skull morphology.
Collapse
Affiliation(s)
- Emilie Robertson
- Division of Plastic Surgery, University of Alberta, Edmonton, AB, Canada
- Institute for Reconstructive Sciences in Medicine, Misericordia Hospital, Edmonton, AB, Canada
| | - Pierre Boulanger
- Department of Computing Sciences, University of Alberta, Edmonton, AB, Canada
| | - Peter Kwan
- Division of Plastic Surgery, University of Alberta, Edmonton, AB, Canada
| | - Gorman Louie
- Division of Plastic Surgery, University of Alberta, Edmonton, AB, Canada
| | - Daniel Aalto
- Institute for Reconstructive Sciences in Medicine, Misericordia Hospital, Edmonton, AB, Canada
- Department of Rehabilitation Sciences, Division of Communication Sciences and Disorders, University of Alberta, Edmonton, AB, Canada
| |
Collapse
|
2
|
Jin X, Chi W. Clinical effect of digitalized designed and 3D-printed repositioning splints in the treatment of anterior displacement of temporomandibular joint disc. BMC Musculoskelet Disord 2024; 25:348. [PMID: 38702659 PMCID: PMC11067177 DOI: 10.1186/s12891-024-07477-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Accepted: 04/26/2024] [Indexed: 05/06/2024] Open
Abstract
OBJECTIVE To compare the treatment effectiveness of digitized and 3D-printed repositioning splints with that of conventional repositioning splints in the treatment of anterior displacement of the temporomandibular joint disc. METHODS This retrospective study included 96 patients with disc displacement of the anterior temporomandibular joint. They were treated with either digitally designed and 3D-printed repositioning splints or traditional splints and followed up for at least six months. Changes in signs and symptoms such as pain and mouth opening before and after treatment were recorded to evaluate treatment outcomes. RESULTS During the first month of treatment, both the digitally designed and 3D-printed repositioning splint groups (Group B) and the traditional repositioning splint group (Group A) showed significant increases in mouth opening, with increases of 4.93 ± 3.06 mm and 4.07 ± 4.69 mm, respectively, and there was no significant difference between the two groups. Both groups had a significant reduction in visual analog scale (VAS) pain scores, with Group B showing a greater reduction of 1.946 ± 1.113 compared to 1.488 ± 0.978 in Group A (P < 0.05). By the sixth month, Group B's mouth opening further improved to 38.65 ± 3.22 mm (P < 0.05), while Group A's mouth opening did not significantly improve. Regarding pain, Group A's VAS score decreased by 0.463 ± 0.778 after one month, and Group B's score decreased by 0.455 ± 0.715; both groups showed significant reductions, but there was no significant difference between the two groups. CONCLUSION Compared with traditional repositioning splints, digitally designed and 3D-printed repositioning splints are more effective at reducing patient pain and improving mouth opening. 3D-printed repositioning splints are an effective treatment method for temporomandibular joint disc displacement and have significant potential for widespread clinical application.
Collapse
Affiliation(s)
- Xiao Jin
- Department of Oral and Maxillofacial Surgery, School & Hospital of Stomatology, Wenzhou Medical University, Wenzhou, Zhejiang, 325000, China
| | - Wang Chi
- Department of Oral and Maxillofacial Surgery, School & Hospital of Stomatology, Wenzhou Medical University, Wenzhou, Zhejiang, 325000, China.
| |
Collapse
|
3
|
Abad-Coronel C, Pazán DP, Hidalgo L, Larriva Loyola J. Comparative Analysis between 3D-Printed Models Designed with Generic and Dental-Specific Software. Dent J (Basel) 2023; 11:216. [PMID: 37754336 PMCID: PMC10529710 DOI: 10.3390/dj11090216] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 08/28/2023] [Accepted: 09/11/2023] [Indexed: 09/28/2023] Open
Abstract
With the great demand in the market for new dental software, the need has been seen to carry out a precision study for applications in digital dentistry, for which there is no comparative study, and there is a general ignorance regarding their applications. The purpose of this study was to investigate the accuracy differences between digital impressions obtained using generic G-CAD (general CAD) and D-CAD (CAD dental) software. Today, there is a difference between the design software used in dentistry and these in common use. Thus, it is necessary to make a comparison of precision software for specific and generic dental use. We hypothesized that there is no significant difference between the software for specific and general dental use. METHODS A typodont was digitized with an intraoral scanner and the models obtained were exported in STL format to four different softwares (Autodesk MeshMixer 3.5, Exocad Dental, Blender for dental, and InLAB). The STL files obtained by each software were materialized using a 3D printer. The printed models were scanned and exported in STL files, with which six pairs of groups were formed. The groups were compared using analysis software (3D Geomagic Control X) by superimposing them in the initial alignment order and using the best fit method. RESULTS There were no significant differences between the four analyzed software types; however, group 4, composed of the combination of D-CAD (Blender-InLAB), obtained the highest average (-0.0324 SD = 0.0456), with a higher accuracy compared to the group with the lowest average (group 5, composed of the combination of the Meshmixer and Blender models), a generic software and a specific software (0.1024 SD = 0.0819). CONCLUSION Although no evidence of significant difference was found regarding the accuracy of 3D models produced by G-CAD and D-CAD, combinations of groups where specific dental design software was present showed higher accuracy (precision and trueness). The comparison of the 3D graphics obtained with the superimposition of the digital meshes of the printed models performed with the help of the analysis software using the best fit method, replicating the same five reference points for the six groups formed, evidenced a greater tolerance in the groups using D-CAD.
Collapse
Affiliation(s)
- Cristian Abad-Coronel
- CAD/CAM Materials and Digital Dentistry Research Group, Faculty of Dentistry, Universidad de Cuenca, Cuenca 010107, Ecuador
| | - Doménica Patricia Pazán
- Faculty of Dentistry, Universidad de Cuenca, Cuenca 010101, Ecuador; (D.P.P.); (L.H.); (J.L.L.)
| | - Lorena Hidalgo
- Faculty of Dentistry, Universidad de Cuenca, Cuenca 010101, Ecuador; (D.P.P.); (L.H.); (J.L.L.)
| | - Jaime Larriva Loyola
- Faculty of Dentistry, Universidad de Cuenca, Cuenca 010101, Ecuador; (D.P.P.); (L.H.); (J.L.L.)
| |
Collapse
|
4
|
Lo LJ, Lin HH. Applications of three-dimensional imaging techniques in craniomaxillofacial surgery: A literature review. Biomed J 2023; 46:100615. [PMID: 37343928 PMCID: PMC10339193 DOI: 10.1016/j.bj.2023.100615] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 05/02/2023] [Accepted: 06/10/2023] [Indexed: 06/23/2023] Open
Abstract
Three-dimensional (3D) imaging technologies are increasingly used in craniomaxillofacial (CMF) surgery, especially to enable clinicians to get an effective approach and obtain better treatment results during different preoperative and postoperative phases, namely during image acquisition and diagnosis, virtual surgical planning (VSP), actual surgery, and treatment outcome assessment. The article presents an overview of 3D imaging technologies used in the aforementioned phases of the most common CMF surgery. We searched for relevant studies on 3D imaging applications in CMF surgery published over the past 10 years in the PubMed, ProQuest (Medline), Web of Science, Science Direct, Clinical Key, and Embase databases. A total of 2094 articles were found, of which 712 were relevant. An additional 26 manually searched articles were included in the analysis. The findings of the review demonstrated that 3D imaging technology is becoming increasingly popular in clinical practice and an essential tool for plastic surgeons. This review provides information that will help researchers and clinicians consider the use of 3D imaging techniques in CMF surgery to improve the quality of surgical procedures and achieve satisfactory treatment outcomes.
Collapse
Affiliation(s)
- Lun-Jou Lo
- Plastic & Reconstructive Surgery and Craniofacial Research Center, Chang Gung Memorial Hospital, Taoyuan, Taiwan; College of Medicine, Chang Gung University, Taoyuan, Taiwan.
| | - Hsiu-Hsia Lin
- College of Medicine, Chang Gung University, Taoyuan, Taiwan; Craniofacial Research Center, Chang Gung Memorial Hospital, Taoyuan, Taiwan.
| |
Collapse
|
5
|
A Look Back: A Single Surgeon’s Experience Using Virtual Surgical Planning in Adult Orthognathic Surgery. J Craniofac Surg 2022; 33:2005-2010. [DOI: 10.1097/scs.0000000000008677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Accepted: 03/10/2022] [Indexed: 11/26/2022] Open
|
6
|
Willinger K, Guevara-Rojas G, Cede J, Schicho K, Stamm T, Klug C. Comparison of feasibility, time consumption and costs of three virtual planning systems for surgical correction of midfacial deficiency. Maxillofac Plast Reconstr Surg 2021; 43:2. [PMID: 33411020 PMCID: PMC7790928 DOI: 10.1186/s40902-020-00284-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Accepted: 11/26/2020] [Indexed: 11/10/2022] Open
Abstract
Background Today virtual surgical planning (VSP) is a standard method in maxillofacial corrective surgery and is the key to reach satisfactory esthetic outcomes. The purpose of this study was to evaluate usability of three established virtual surgical planning software applications by comparing feasibility, time consumption, and costs in a standardized workflow for a modified intraoral quadrangular Le Fort II osteotomy (IQLFIIO). Results A cross-sectional study was performed based on retrospective and re-planned data of patients with midfacial deficiency treated by modified IQLFIIO, using three software applications: IPS Case Designer ®, Dolphin Imaging ®, and ProPlan CMF ®. Feasibility: All evaluated steps of the VSP procedure could be successfully performed in all three evaluated applications. In all software packages, it was possible to design the surgical splints with CAD/CAM technology. Working time: The mean value of time needed was IPS Case Designer ®, 36.5 min; Dolphin Imaging ®, 33.6 min; ProPlan CMF ®, 45.5 min. We found statistical significant difference between ProPlan CMF ® and Dolphin Imaging ® (p value, 0.02). Costs: Asset costs for acquiring the software, license fee, license possibilities, paying for support services, and service contracts were evaluated and are found in similar ranges. Conclusion All three tested software applications are usable for virtual planning of an IQLFIIO and splint production by CAD/CAM technology. Successful movement of bone segments and overlaying soft tissues proved feasibility. Time consumption and costs were found in similar ranges.
Collapse
Affiliation(s)
- Katrin Willinger
- University Clinic of Cranio- and Maxillofacial Surgery, Medical University of Vienna, Vienna, Austria.
| | | | - Julia Cede
- University Clinic of Cranio- and Maxillofacial Surgery, Medical University of Vienna, Vienna, Austria
| | - Kurt Schicho
- University Clinic of Cranio- and Maxillofacial Surgery, Medical University of Vienna, Vienna, Austria
| | - Tanja Stamm
- Center for Medical Statistics, Informatics and Intelligent Systems (CeMSIIS), Medical University of Vienna, Vienna, Austria
| | - Clemens Klug
- University Clinic of Cranio- and Maxillofacial Surgery, Medical University of Vienna, Vienna, Austria.
| |
Collapse
|
7
|
Wang E, Shi H, Sun Y, Politis C, Lan L, Chen X. Computer‐aided porous implant design for cranio‐maxillofacial defect restoration. Int J Med Robot 2020; 16:1-10. [DOI: 10.1002/rcs.2134] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Revised: 05/28/2020] [Accepted: 05/29/2020] [Indexed: 11/06/2022]
Affiliation(s)
- Enpeng Wang
- School of Mechanical Engineering Shanghai Jiao Tong University Shanghai China
| | - Haochen Shi
- School of Mechanical Engineering Shanghai Jiao Tong University Shanghai China
| | - Yi Sun
- Department of Oral and Maxillofacial Surgery/Faculty of Medicine KU Leuven University Hospitals Leuven, Campus Sint‐Rafaël and Department of Imaging Leuven Belgium
| | - Constantinus Politis
- Department of Oral and Maxillofacial Surgery/Faculty of Medicine KU Leuven University Hospitals Leuven, Campus Sint‐Rafaël and Department of Imaging Leuven Belgium
| | - Lin Lan
- Department of Oral and Maxillofacial Surgery Peking University School and Hospital of Stomatology Beijing China
| | - Xiaojun Chen
- School of Mechanical Engineering Shanghai Jiao Tong University Shanghai China
| |
Collapse
|
8
|
Memon AR, Wang E, Hu J, Egger J, Chen X. A review on computer-aided design and manufacturing of patient-specific maxillofacial implants. Expert Rev Med Devices 2020; 17:345-356. [PMID: 32105159 PMCID: PMC7175472 DOI: 10.1080/17434440.2020.1736040] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2019] [Accepted: 02/25/2020] [Indexed: 10/25/2022]
Abstract
Introduction: Various prefabricated maxillofacial implants are used in the clinical routine for the surgical treatment of patients. In addition to these prefabricated implants, customized CAD/CAM implants become increasingly important for a more precise replacement of damaged anatomical structures. This paper reviews the design and manufacturing of patient-specific implants for the maxillofacial area.Areas covered: The contribution of this publication is to give a state-of-the-art overview in the usage of customized facial implants. Moreover, it provides future perspectives, including 3D printing technologies, for the manufacturing of patient-individual facial implants that are based on patient's data acquisitions, like Computed Tomography (CT) or Magnetic Resonance Imaging (MRI).Expert opinion: The main target of this review is to present various designing software and 3D manufacturing technologies that have been applied to fabricate facial implants. In doing so, different CAD designing software's are discussed, which are based on various methods and have been implemented and evaluated by researchers. Finally, recent 3D printing technologies that have been applied to manufacture patient-individual implants will be introduced and discussed.
Collapse
Affiliation(s)
- Afaque Rafique Memon
- Institute of Biomedical Manufacturing and Life Quality Engineering, State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Enpeng Wang
- Institute of Biomedical Manufacturing and Life Quality Engineering, State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Junlei Hu
- Institute of Biomedical Manufacturing and Life Quality Engineering, State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Jan Egger
- Institute of Biomedical Manufacturing and Life Quality Engineering, State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Institute for Computer Graphics and Vision, Faculty of Computer Science and Biomedical Engineering, Graz University of Technology, Graz, Austria
- Department of Oral &maxillofacial Surgery, Medical University of Graz, Graz, Austria
- The Laboratory of Computer Algorithms for Medicine, Medical University of Graz, Graz, Austria
| | - Xiaojun Chen
- Institute of Biomedical Manufacturing and Life Quality Engineering, State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
9
|
Chepelev L, Wake N, Ryan J, Althobaity W, Gupta A, Arribas E, Santiago L, Ballard DH, Wang KC, Weadock W, Ionita CN, Mitsouras D, Morris J, Matsumoto J, Christensen A, Liacouras P, Rybicki FJ, Sheikh A. Radiological Society of North America (RSNA) 3D printing Special Interest Group (SIG): guidelines for medical 3D printing and appropriateness for clinical scenarios. 3D Print Med 2018; 4:11. [PMID: 30649688 PMCID: PMC6251945 DOI: 10.1186/s41205-018-0030-y] [Citation(s) in RCA: 144] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Accepted: 09/19/2018] [Indexed: 02/08/2023] Open
Abstract
Medical three-dimensional (3D) printing has expanded dramatically over the past three decades with growth in both facility adoption and the variety of medical applications. Consideration for each step required to create accurate 3D printed models from medical imaging data impacts patient care and management. In this paper, a writing group representing the Radiological Society of North America Special Interest Group on 3D Printing (SIG) provides recommendations that have been vetted and voted on by the SIG active membership. This body of work includes appropriate clinical use of anatomic models 3D printed for diagnostic use in the care of patients with specific medical conditions. The recommendations provide guidance for approaches and tools in medical 3D printing, from image acquisition, segmentation of the desired anatomy intended for 3D printing, creation of a 3D-printable model, and post-processing of 3D printed anatomic models for patient care.
Collapse
Affiliation(s)
- Leonid Chepelev
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| | - Nicole Wake
- Center for Advanced Imaging Innovation and Research (CAI2R), Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, NYU School of Medicine, New York, NY USA
- Sackler Institute of Graduate Biomedical Sciences, NYU School of Medicine, New York, NY USA
| | | | - Waleed Althobaity
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| | - Ashish Gupta
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| | - Elsa Arribas
- Department of Diagnostic Radiology, Division of Diagnostic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX USA
| | - Lumarie Santiago
- Department of Diagnostic Radiology, Division of Diagnostic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX USA
| | - David H Ballard
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, Saint Louis, MO USA
| | - Kenneth C Wang
- Baltimore VA Medical Center, University of Maryland Medical Center, Baltimore, MD USA
| | - William Weadock
- Department of Radiology and Frankel Cardiovascular Center, University of Michigan, Ann Arbor, MI USA
| | - Ciprian N Ionita
- Department of Neurosurgery, State University of New York Buffalo, Buffalo, NY USA
| | - Dimitrios Mitsouras
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| | | | | | - Andy Christensen
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| | - Peter Liacouras
- 3D Medical Applications Center, Walter Reed National Military Medical Center, Washington, DC, USA
| | - Frank J Rybicki
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| | - Adnan Sheikh
- Department of Radiology and The Ottawa Hospital Research Institute, University of Ottawa, Ottawa, ON Canada
| |
Collapse
|