1
|
Kashyap S, Almutairi Z, Qin N, Zhao P, Bedi S, Johnson D, Ren CL. Effects of surfactant size and concentration on the internal flow fields of moving slug and Disk-like droplets via μ-PIV. Chem Eng Sci 2022. [DOI: 10.1016/j.ces.2022.117668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
2
|
Microfluidic free-flow electrophoresis: a promising tool for protein purification and analysis in proteomics. J IND ENG CHEM 2022. [DOI: 10.1016/j.jiec.2022.02.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
3
|
Whole-Column Imaging Detection for Capillary Isoelectric Focusing: Its Applications in Pharmaceutical Industry and Recent Development of the Technology. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116567] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
4
|
Badiye A, Kapoor N, Shukla RK. Detection and separation of proteins using micro/nanofluidics devices. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2022; 186:59-84. [PMID: 35033290 DOI: 10.1016/bs.pmbts.2021.07.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Microfluidics is the technology or system wherein the behavior of fluids' is studied onto a miniaturized device composed of chambers and tunnels. In biological and biomedical sciences, microfluidic technology/system or device serves as an ultra-high-output approach capable of detecting and separating the biomolecules present even in trace quantities. Given the essential role of protein, the identification and quantification of proteins help understand the various living systems' biological function regulation. Microfluidics has enormous potential to enable biological investigation at the cellular and molecular level and maybe a fair substitution of the sophisticated instruments/equipment used for proteomics, genomics, and metabolomics analysis. The current advancement in microfluidic systems' development is achieving momentum and opening new avenues in developing innovative and hybrid methodologies/technologies. This chapter attempts to expound the micro/nanofluidic systems/devices for their wide-ranging application to detect and separate protein. It covers microfluidic chip electrophoresis, microchip gel electrophoresis, and nanofluidic systems as protein separation systems, while methods such as spectrophotometric, mass spectrometry, electrochemical detection, magneto-resistive sensors and dynamic light scattering (DLS) are discussed as proteins' detection system.
Collapse
Affiliation(s)
- Ashish Badiye
- Department of Forensic Science, Government Institute of Forensic Sciences, Nagpur, Maharashtra, India
| | - Neeti Kapoor
- Department of Forensic Science, Government Institute of Forensic Sciences, Nagpur, Maharashtra, India
| | - Ritesh K Shukla
- Biological and Life Sciences, School of Arts and Sciences, Ahmedabad University, Ahmedabad, Gujarat, India.
| |
Collapse
|
5
|
Isoelectric focusing array with immobilized pH gradient and dynamic scanning imaging for diabetes diagnosis. Anal Chim Acta 2019; 1063:178-186. [DOI: 10.1016/j.aca.2019.03.014] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2018] [Revised: 03/02/2019] [Accepted: 03/07/2019] [Indexed: 12/24/2022]
|
6
|
Rodríguez-Ruiz I, Babenko V, Martínez-Rodríguez S, Gavira JA. Protein separation under a microfluidic regime. Analyst 2017; 143:606-619. [PMID: 29214270 DOI: 10.1039/c7an01568b] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Lab-on-a-Chip (LoC), or micro-Total Analysis Systems (μTAS), is recognized as a powerful analytical technology with high capabilities, though end-user products for protein purification are still far from being available on the market. Remarkable progress has been achieved in the separation of nucleic acids and proteins using electrophoretic microfluidic devices, while pintsize devices have been developed for protein isolation according to miniaturized chromatography principles (size, charge, affinity, etc.). In this work, we review the latest advances in the fabrication of components, detection methods and commercial implementation for the separation of biological macromolecules based on microfluidic systems, with some critical remarks on the perspectives of their future development towards standardized microfluidic systems and protocols. An outlook on the current needs and future applications is also presented.
Collapse
Affiliation(s)
| | - V Babenko
- Laboratorio de Estudios Cristalograficos, Instituto Andaluz de Ciencias de la Tierra, CSIC-University of Granada, Avenida de las Palmeras 4, 18100 Armilla, Granada, Spain.
| | - S Martínez-Rodríguez
- Department of Biochemistry and Molecular Biology III and Immunology. University of Granada, Granada, Spain
| | - J A Gavira
- Laboratorio de Estudios Cristalograficos, Instituto Andaluz de Ciencias de la Tierra, CSIC-University of Granada, Avenida de las Palmeras 4, 18100 Armilla, Granada, Spain.
| |
Collapse
|
7
|
Zeng H, Glawdel T, Ren CL. Microchip with an open tubular immobilized ph gradient for UV whole column imaging detection. Electrophoresis 2015; 36:2542-5. [PMID: 26101201 DOI: 10.1002/elps.201500041] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2015] [Revised: 06/09/2015] [Accepted: 06/10/2015] [Indexed: 01/06/2023]
Abstract
This study reports a new method for establishing an open tubular IPG in a microchip coupled with a whole column image detection (WCID) system for protein separation applications. This method allows a wider range of immobilized pH (2.6-9.5) to be established in a PDMS/quartz channel by controlling the diffusion of acidic and basic polymer solutions into the channel through well-designed channel dimensions. The developed pH gradient was experimentally validated by performing the separation of a mixture of standard pI markers. It was further validated by the separation of the hemoglobin control AFSC sample. This method is advantageous over existing IPG methods because it has a wider range of pH and maintains the open tubular feature that matches the UV WCID to improve the sensitivity.
Collapse
Affiliation(s)
- Hulie Zeng
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON, Canada
| | - Tomasz Glawdel
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON, Canada
| | - Carolyn L Ren
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON, Canada
| |
Collapse
|
8
|
Li S, Dong JY, Guo CG, Wu YX, Zhang W, Fan LY, Cao CX, Zhang WB. A stable and high-resolution isoelectric focusing capillary array device for micropreparative separation of proteins. Talanta 2013; 116:259-65. [DOI: 10.1016/j.talanta.2013.05.041] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2013] [Revised: 05/16/2013] [Accepted: 05/19/2013] [Indexed: 12/13/2022]
|
9
|
Nge PN, Rogers CI, Woolley AT. Advances in microfluidic materials, functions, integration, and applications. Chem Rev 2013; 113:2550-83. [PMID: 23410114 PMCID: PMC3624029 DOI: 10.1021/cr300337x] [Citation(s) in RCA: 515] [Impact Index Per Article: 46.8] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Pamela N. Nge
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602
| | - Chad I. Rogers
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602
| | - Adam T. Woolley
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602
| |
Collapse
|
10
|
Ou J, Ren CL. Microchip UV absorbance detection applied to isoelectric focusing of proteins. Methods Mol Biol 2013; 949:507-521. [PMID: 23329463 DOI: 10.1007/978-1-62703-134-9_32] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Isoelectric focusing (IEF) is considered as an attractive separation technique for biologically amphoteric compounds (e.g., proteins and peptides) based on their isoelectric point (pI). With the advancement in micromachining technology, microchip format IEF has attracted significant attention. Both single-point and whole column imaging detection (WCID) methods have been employed for analyzing the separation performance in a microchip. WCID is more favorable than single-point detection because the latter requires the focused bands to be mobilized and thus adds more complexity to the design and operation of such microchips. Fluorescence- and UV absorbance-based WCID have been successfully adapted in glass and PDMS microchips. We have developed polydimethylsiloxane (PDMS) microchips for IEF applications where UV-WCID is employed for evaluating the separation performance. The chips are designed for use in the iCE280 analyzer (Convergent Bioscience Inc., Toronto), for capillary-based IEF where UV-WCID is employed for analyzing the separation performance. Three kinds of microchips that have been successfully developed using standard soft lithography technology are described in detail.
Collapse
Affiliation(s)
- Junjie Ou
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON, Canada
| | | |
Collapse
|
11
|
Li L, Bi X, Yu J, Ren CL, Liu Z. A new soft lithographic route for the facile fabrication of hydrophilic sandwich microchips. Electrophoresis 2012; 33:2591-7. [PMID: 22899268 DOI: 10.1002/elps.201200206] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Manufacturing materials are an essential element for the fabrication of microfluidic chips. PDMS, the most widely used polymeric material, is associated with apparent disadvantages such as hydrophobic nature, while other materials also suffer from some limitations. In this paper, a new soft lithographic route was proposed for the facile manufacturing of hydrophilic sandwich microchips, using bisphenol A based epoxy acrylate (BABEA) as a new patterning material. The BABEA copolymers are hydrophilic, highly transparent in visible range while highly untransparent when the wavelength is less than 290 nm, and of high replication fidelity. By combining with appropriate monomers, including glycidyl methacrylate, methylmethacrylate, and acrylic acid, the copolymers contain active functional groups, which allows for easy postmodification for desirable functional units. A fabrication procedure was proposed for manufacturing hybrid quartz/BABEA copolymer/quartz microchips. In the procedure, no micromachining equipments, wet etching, or imprinting techniques were involved, making the fabrication approach applicable in ordinary chemistry laboratories. The performance of the prepared microchips was demonstrated in terms of CIEF with UV-whole channel imaging detection. The hydrophilic microchannel ensures stable focusing while the polymeric middle layer acts as a perfectly aligned optical slit for whole channel UV absorbance detection.
Collapse
Affiliation(s)
- Li Li
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, China
| | | | | | | | | |
Collapse
|
12
|
Köhler S, Nagl S, Fritzsche S, Belder D. Label-free real-time imaging in microchip free-flow electrophoresis applying high speed deep UV fluorescence scanning. LAB ON A CHIP 2012; 12:458-463. [PMID: 22011722 DOI: 10.1039/c1lc20558g] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We report on label-free monitoring of microfluidic free-flow electrophoresis (μFFE) separations in real-time using a custom built high speed deep UV laser scanner. In combination with a novel layout realized in fused silica (FS) FFE chips the setup was successfully applied for continuous separations and detection of unlabeled analytes including native proteins by space-resolved intrinsic deep UV fluorescence scanning.
Collapse
Affiliation(s)
- Stefan Köhler
- Institute of Analytical Chemistry, University of Leipzig, Linnéstr. 3, 04103 Leipzig, Germany
| | | | | | | |
Collapse
|
13
|
Bi X, Yu J, Li L, Jiang H, Huang F, Liu Z. Spatio-temporally resolved detection on a microfluidic chip for monitoring the dynamic processes of molecular events. Analyst 2012; 137:4016-22. [DOI: 10.1039/c2an35650c] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
14
|
Shameli SM, Elbuken C, Ou J, Ren CL, Pawliszyn J. Fully integrated PDMS/SU-8/quartz microfluidic chip with a novel macroporous poly dimethylsiloxane (PDMS) membrane for isoelectric focusing of proteins using whole-channel imaging detection. Electrophoresis 2010; 32:333-9. [PMID: 21298660 DOI: 10.1002/elps.201000643] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2010] [Revised: 12/03/2010] [Accepted: 12/09/2010] [Indexed: 01/02/2023]
Abstract
A fully integrated polydimethylsiloxane (PDMS)/modified PDMS membrane/SU-8/quartz hybrid chip was developed for protein separation using isoelectric focusing (IEF) mechanism coupled with whole-channel imaging detection (WCID) method. This microfluidic chip integrates three components into one single chip: (i) modified PDMS membranes for separating electrolytes in the reservoirs from the sample in the microchannel and thus reducing pressure disturbance, (ii) SU-8 optical slit to block UV light (below 300 nm) outside the channel aiming to increase detection sensitivity, and (iii) injection and discharge capillaries for continuous operation. Integration of all these components on a single chip is challenging because it requires fabrication techniques for perfect bonding between different materials and is prone to leakage and blockage. This study has addressed all the challenges and presented a fully integrated chip, which is more robust with higher sensitivity than the previously developed IEF chips. This chip was tested by performing protein and pI marker separation. The separation results obtained in this chip were compared with that obtained in commercial cartridges. Side-by-side comparison validated the developed chip and fabrication techniques.
Collapse
Affiliation(s)
- Seyed Mostafa Shameli
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON, Canada
| | | | | | | | | |
Collapse
|
15
|
Ou J, Glawdel T, Ren CL, Pawliszyn J. Fabrication of a hybrid PDMS/SU-8/quartz microfluidic chip for enhancing UV absorption whole-channel imaging detection sensitivity and application for isoelectric focusing of proteins. LAB ON A CHIP 2009; 9:1926-1932. [PMID: 19532968 DOI: 10.1039/b821438g] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
A poly(dimethylsiloxane)(PDMS)/SU-8/quartz hybrid chip was developed and applied in the isoelectric focusing (IEF) of proteins with ultraviolet (UV) absorbance-based whole-channel imaging detection (UV-WCID). Each hybrid chip was made of three layers: a PDMS flat top substrate, a bottom quartz substrate and a middle layer of SU-8 photoresist. The SU-8 serves two purposes: it contains the microchannel used for IEF separation, and acts as an optical slit that absorbs UV light below 300 nm improving detection sensitivity in WCID. The novel hybrid design demonstrates a two to three times improvement in sensitivity over a comparable PDMS/PDMS design. In addition, the hybrid chip exhibits increased heat dissipation due to the superior thermal conductivity of the bottom quartz substrate allowing for larger electric fields to be used in separations. The hybrid design with IEF-UV-WCID was successful in resolving a complicated sample, hemoglobin control, with high fidelity.
Collapse
Affiliation(s)
- Junjie Ou
- Department of Chemistry, University of Waterloo, Waterloo, Ontario, CanadaN2L 3G1
| | | | | | | |
Collapse
|
16
|
|