1
|
Burian M, Meisenbichler C, Naumenko D, Amenitsch H. SAXSDOG: open software for real-time azimuthal integration of 2D scattering images. J Appl Crystallogr 2022; 55:677-685. [PMID: 35719301 PMCID: PMC9172040 DOI: 10.1107/s1600576722003685] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Accepted: 04/02/2022] [Indexed: 11/10/2022] Open
Abstract
In situ small- and wide-angle scattering experiments at synchrotrons often result in massive quantities of data within just seconds. Especially during such beamtimes, processing of the acquired data online, without appreciable delay, is key to obtaining feedback on the failure or success of the experiment. This had led to the development of SAXSDOG, a Python-based environment for real-time azimuthal integration of large-area scattering images. The software is primarily designed for dedicated data pipelines: once a scattering image is transferred from the detector onto the storage unit, it is automatically integrated and pre-evaluated using integral parameters within milliseconds. The control and configuration of the underlying server-based processes is achieved via a graphical user interface, SAXSLEASH, which visualizes the resulting 1D data together with integral classifiers in real time. SAXSDOG further includes a portable `take-home' version for users that runs on standalone computers, enabling its use in laboratories or at the preferred workspace.
Collapse
|
2
|
Maged A, Abdelbaset R, Mahmoud AA, Elkasabgy NA. Merits and advances of microfluidics in the pharmaceutical field: design technologies and future prospects. Drug Deliv 2022; 29:1549-1570. [PMID: 35612293 PMCID: PMC9154770 DOI: 10.1080/10717544.2022.2069878] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Microfluidics is used to manipulate fluid flow in micro-channels to fabricate drug delivery vesicles in a uniform tunable size. Thanks to their designs, microfluidic technology provides an alternative and versatile platform over traditional formulation methods of nanoparticles. Understanding the factors that affect the formulation of nanoparticles can guide the proper selection of microfluidic design and the operating parameters aiming at producing nanoparticles with reproducible properties. This review introduces the microfluidic systems' continuous flow (single-phase) and segmented flow (multiphase) and their different mixing parameters and mechanisms. Furthermore, microfluidic approaches for efficient production of nanoparticles as surface modification, anti-fouling, and post-microfluidic treatment are summarized. The review sheds light on the used microfluidic systems and operation parameters applied to prepare and fine-tune nanoparticles like lipid, poly(lactic-co-glycolic acid) (PLGA)-based nanoparticles as well as cross-linked nanoparticles. The approaches for scale-up production using microfluidics for clinical or industrial use are also highlighted. Furthermore, the use of microfluidics in preparing novel micro/nanofluidic drug delivery systems is presented. In conclusion, the characteristic vital features of microfluidics offer the ability to develop precise and efficient drug delivery nanoparticles.
Collapse
Affiliation(s)
- Amr Maged
- Department of Pharmaceutics and Pharmaceutical Technology, Faculty of Pharmacy, Future University in Egypt, Cairo, Egypt.,Pharmaceutical Factory, Faculty of Pharmacy, Future University in Egypt, Cairo, Egypt
| | - Reda Abdelbaset
- Department of Biomedical Engineering, Faculty of Engineering, Helwan University, Cairo, Egypt
| | - Azza A Mahmoud
- Department of Pharmaceutics and Pharmaceutical Technology, Faculty of Pharmacy, Future University in Egypt, Cairo, Egypt
| | - Nermeen A Elkasabgy
- Department of Pharmaceutics and Industrial Pharmacy, Faculty of Pharmacy, Cairo University, Cairo, Egypt
| |
Collapse
|
3
|
Vakili M, Bielecki J, Knoška J, Otte F, Han H, Kloos M, Schubert R, Delmas E, Mills G, de Wijn R, Letrun R, Dold S, Bean R, Round A, Kim Y, Lima FA, Dörner K, Valerio J, Heymann M, Mancuso AP, Schulz J. 3D printed devices and infrastructure for liquid sample delivery at the European XFEL. JOURNAL OF SYNCHROTRON RADIATION 2022; 29:331-346. [PMID: 35254295 PMCID: PMC8900844 DOI: 10.1107/s1600577521013370] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 12/16/2021] [Indexed: 06/14/2023]
Abstract
The Sample Environment and Characterization (SEC) group of the European X-ray Free-Electron Laser (EuXFEL) develops sample delivery systems for the various scientific instruments, including systems for the injection of liquid samples that enable serial femtosecond X-ray crystallography (SFX) and single-particle imaging (SPI) experiments, among others. For rapid prototyping of various device types and materials, sub-micrometre precision 3D printers are used to address the specific experimental conditions of SFX and SPI by providing a large number of devices with reliable performance. This work presents the current pool of 3D printed liquid sample delivery devices, based on the two-photon polymerization (2PP) technique. These devices encompass gas dynamic virtual nozzles (GDVNs), mixing-GDVNs, high-viscosity extruders (HVEs) and electrospray conical capillary tips (CCTs) with highly reproducible geometric features that are suitable for time-resolved SFX and SPI experiments at XFEL facilities. Liquid sample injection setups and infrastructure on the Single Particles, Clusters, and Biomolecules and Serial Femtosecond Crystallography (SPB/SFX) instrument are described, this being the instrument which is designated for biological structure determination at the EuXFEL.
Collapse
Affiliation(s)
| | | | - Juraj Knoška
- Center for Free-Electron Laser Science (CFEL), Deutsches Elektronen-Synchrotron (DESY), Notkestrasse 85, 22607 Hamburg, Germany
| | - Florian Otte
- European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany
- Department of Physics, TU Dortmund, Otto-Hahn-Straße 4, 44221 Dortmund, Germany
| | - Huijong Han
- European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany
| | - Marco Kloos
- European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany
| | | | - Elisa Delmas
- European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany
| | - Grant Mills
- European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany
| | | | - Romain Letrun
- European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany
| | - Simon Dold
- European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany
| | - Richard Bean
- European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany
| | - Adam Round
- European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany
- School of Chemical and Physical Sciences, Keele University, Staffordshire ST5 5AZ, United Kingdom
| | - Yoonhee Kim
- European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany
| | | | | | - Joana Valerio
- European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany
| | - Michael Heymann
- Institute for Biomaterials and Biomolecular Systems (IBBS), University of Stuttgart, Pfaffenwaldring 57, 70569 Stuttgart, Germany
| | - Adrian P. Mancuso
- European XFEL, Holzkoppel 4, 22869 Schenefeld, Germany
- Department of Chemistry and Physics, La Trobe Institute for Molecular Science (LIMS), La Trobe University, Melbourne 3086, Australia
| | | |
Collapse
|
4
|
Duarte LC, Pereira I, Maciel LIL, Vaz BG, Coltro WKT. 3D printed microfluidic mixer for real-time monitoring of organic reactions by direct infusion mass spectrometry. Anal Chim Acta 2022; 1190:339252. [PMID: 34857139 DOI: 10.1016/j.aca.2021.339252] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 08/31/2021] [Accepted: 11/03/2021] [Indexed: 12/26/2022]
Abstract
3D printing is a technology that has revolutionized traditional rapid prototyping methods due to its ability to build microscale structures with customized geometries in a simple, fast, and low-cost way. In this sense, this article describes the development of a microfluidic mixing device to monitor chemical reactions by mass spectrometry (MS). Microfluidic mixers were designed containing 3D serpentine and Y-shaped microchannels, both with a pointed end for facilitating the spray formation. The devices were fabricated entirely by 3D printing with fusion deposition modeling (FDM) technology. As proof-of-concept, micromixers were evaluated through monitoring the Katritzky reaction by injecting simultaneously 2,4,6-triphenylpropyllium (TPP) and amino acid (glycine or alanine) solutions, each through a different reactor inlet. Reaction product was monitored online by MS at different flow rates. Mass spectra showed that the relative abundances of the products obtained with the device containing the 3D serpentine channel were three times greater than those obtained with the Y-channel device due to the turbulence generated by the barriers created inside microchannels. In addition, when compared to the conventional electrospray ionization mass spectrometry (ESI-MS) technique, the 3D serpentine mixer offered better performance measured in relation to the relative abundance values for the reaction products. These results as well as the instrumental simplicity indicate that 3D printed microfluidic mixer is a promising tool for monitoring organic reactions via MS.
Collapse
Affiliation(s)
- Lucas C Duarte
- Instituto de Química, Universidade Federal de Goiás, Campus Samambaia, 74690-900, Goiânia, GO, Brazil
| | - Igor Pereira
- Instituto de Química, Universidade Federal de Goiás, Campus Samambaia, 74690-900, Goiânia, GO, Brazil
| | - Lanaia I L Maciel
- Instituto de Química, Universidade Federal de Goiás, Campus Samambaia, 74690-900, Goiânia, GO, Brazil
| | - Boniek G Vaz
- Instituto de Química, Universidade Federal de Goiás, Campus Samambaia, 74690-900, Goiânia, GO, Brazil
| | - Wendell K T Coltro
- Instituto de Química, Universidade Federal de Goiás, Campus Samambaia, 74690-900, Goiânia, GO, Brazil; Instituto Nacional de Ciência e Tecnologia de Bioanalítica, 13084-971, Campinas, SP, Brazil.
| |
Collapse
|
5
|
Hejazian M, Balaur E, Abbey B. Recent Advances and Future Perspectives on Microfluidic Mix-and-Jet Sample Delivery Devices. MICROMACHINES 2021; 12:531. [PMID: 34067131 PMCID: PMC8151207 DOI: 10.3390/mi12050531] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 05/04/2021] [Accepted: 05/04/2021] [Indexed: 11/28/2022]
Abstract
The integration of the Gas Dynamic Virtual Nozzle (GDVN) and microfluidic technologies has proven to be a promising sample delivery solution for biomolecular imaging studies and has the potential to be transformative for a range of applications in physics, biology, and chemistry. Here, we review the recent advances in the emerging field of microfluidic mix-and-jet sample delivery devices for the study of biomolecular reaction dynamics. First, we introduce the key parameters and dimensionless numbers involved in their design and characterisation. Then we critically review the techniques used to fabricate these integrated devices and discuss their advantages and disadvantages. We then summarise the most common experimental methods used for the characterisation of both the mixing and jetting components. Finally, we discuss future perspectives on the emerging field of microfluidic mix-and-jet sample delivery devices. In summary, this review aims to introduce this exciting new topic to the wider microfluidics community and to help guide future research in the field.
Collapse
Affiliation(s)
| | | | - Brian Abbey
- ARC Centre of Excellence in Advanced Molecular Imaging, Department of Chemistry and Physics, La Trobe Institute for Molecular Sciences, La Trobe University, Melbourne, VIC 3086, Australia; (M.H.); (E.B.)
| |
Collapse
|
6
|
Production of Uniform Microspheres Using a Simple Microfluidic Device with Silica Capillary. Macromol Res 2021. [DOI: 10.1007/s13233-021-9012-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
7
|
Vakili M, Vasireddi R, Gwozdz PV, Monteiro DCF, Heymann M, Blick RH, Trebbin M. Microfluidic polyimide gas dynamic virtual nozzles for serial crystallography. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:085108. [PMID: 32872940 DOI: 10.1063/5.0012806] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Accepted: 07/05/2020] [Indexed: 06/11/2023]
Abstract
Free liquid jets are a common sample delivery method in serial femtosecond x-ray (SFX) crystallography. Gas dynamic virtual nozzles (GDVNs) use an outer gas stream to focus a liquid jet down to a few micrometers in diameter. Such nozzles can be fabricated through various methods (capillary grinding, soft lithography, digital light processing, and two-photon polymerization) and materials, such as glass, polydimethylsiloxane, and photosensitive polyacrylates. Here, we present a broadly accessible, rapid prototyping laser ablation approach to micromachine solvent-resistant and inert Kapton polyimide foils with highly reproducible geometric features that result in 3D flow-focused GDVNs suitable for crystallography experiments at synchrotrons and free-electron laser facilities.
Collapse
Affiliation(s)
- Mohammad Vakili
- Centre for Ultrafast Imaging (CUI), University of Hamburg, Luruper Chaussee 149, 22761 Hamburg, Germany
| | - Ramakrishna Vasireddi
- Centre for Ultrafast Imaging (CUI), University of Hamburg, Luruper Chaussee 149, 22761 Hamburg, Germany
| | - Paul V Gwozdz
- Center for Hybrid Nanostructures (CHyN), University of Hamburg, Luruper Chaussee 149, 22761 Hamburg, Germany
| | - Diana C F Monteiro
- Centre for Ultrafast Imaging (CUI), University of Hamburg, Luruper Chaussee 149, 22761 Hamburg, Germany
| | - Michael Heymann
- Center for Free-Electron Laser Science (CFEL), DESY, Notkestraße 85, 22607 Hamburg, Germany
| | - Robert H Blick
- Center for Hybrid Nanostructures (CHyN), University of Hamburg, Luruper Chaussee 149, 22761 Hamburg, Germany
| | - Martin Trebbin
- Hauptman-Woodward Medical Research Institute, 700 Ellicott Street, Buffalo, New York 14203, USA
| |
Collapse
|
8
|
Burian M, Marmiroli B, Radeticchio A, Morello C, Naumenko D, Biasiol G, Amenitsch H. Picosecond pump-probe X-ray scattering at the Elettra SAXS beamline. JOURNAL OF SYNCHROTRON RADIATION 2020; 27:51-59. [PMID: 31868736 PMCID: PMC6927520 DOI: 10.1107/s1600577519015728] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Accepted: 11/20/2019] [Indexed: 06/10/2023]
Abstract
A new setup for picosecond pump-probe X-ray scattering at the Austrian SAXS beamline at Elettra-Sincrotrone Trieste is presented. A high-power/high-repetion-rate laser has been installed on-site, delivering UV/VIS/IR femtosecond-pulses in-sync with the storage ring. Data acquisition is achieved by gating a multi-panel detector, capable of discriminating the single X-ray pulse in the dark-gap of the Elettra hybrid filling mode. Specific aspects of laser- and detection-synchronization, on-line beam steering as well protocols for spatial and temporal overlap of laser and X-ray beam are also described. The capabilities of the setup are demonstrated by studying transient heat-transfer in an In/Al/GaAs superlattice structure and results are confirmed by theoretical calculations.
Collapse
Affiliation(s)
- Max Burian
- Institute of Inorganic Chemistry, Graz University of Technology, Stremayrgasse 9/V, 8010 Graz, Austria
| | - Benedetta Marmiroli
- Institute of Inorganic Chemistry, Graz University of Technology, Stremayrgasse 9/V, 8010 Graz, Austria
| | - Andrea Radeticchio
- Institute of Inorganic Chemistry, Graz University of Technology, Stremayrgasse 9/V, 8010 Graz, Austria
| | - Christian Morello
- Elettra-Sincrotrone Trieste SCpA, Strada Statale 14, km 163.5, Basovizza, TS 34149, Italy
| | - Denys Naumenko
- Institute of Inorganic Chemistry, Graz University of Technology, Stremayrgasse 9/V, 8010 Graz, Austria
| | - Giorgio Biasiol
- Laboratorio TASC, CNR-IOM at Area Science Park, Strada Statale 14, km 163.5, Basovizza, TS 34149, Italy
| | - Heinz Amenitsch
- Institute of Inorganic Chemistry, Graz University of Technology, Stremayrgasse 9/V, 8010 Graz, Austria
| |
Collapse
|
9
|
Erokhin KS, Gordeev EG, Ananikov VP. Revealing interactions of layered polymeric materials at solid-liquid interface for building solvent compatibility charts for 3D printing applications. Sci Rep 2019; 9:20177. [PMID: 31882642 PMCID: PMC6934857 DOI: 10.1038/s41598-019-56350-w] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Accepted: 12/11/2019] [Indexed: 11/09/2022] Open
Abstract
Poor stability of 3D printed plastic objects in a number of solvents limits several important applications in engineering, chemistry and biology. Due to layered type of assembling, 3D-printed surfaces possess rather different properties as compared to bulk surfaces made by other methods. Here we study fundamental interactions at the solid-liquid interface and evaluate polymeric materials towards advanced additive manufacturing. A simple and universal stability test was developed for 3D printed parts and applied to a variety of thermoplastics. Specific modes of resistance/destruction were described for different plastics and their compatibility to a representative scope of solvents (aqueous and organic) was evaluated. Classification and characterization of destruction modes for a wide range of conditions (including geometry and 3D printing parameters) were carried out. Key factors of tolerance to solvent media were investigated by electron microscopy. We show that the overall stability and the mode of destruction depend on chemical properties of the polymer and the nature of interactions at the solid-liquid interface. Importantly, stability also depends on the layered microstructure of the sample, which is defined by 3D printing parameters. Developed solvent compatibility charts for a wide range of polymeric materials (ABS, PLA, PLA-Cu, PETG, SBS, Ceramo, HIPS, Primalloy, Photoresin, Nylon, Nylon-C, POM, PE, PP) and solvents represent an important benchmark for practical applications.
Collapse
Affiliation(s)
- Kirill S Erokhin
- Zelinsky Institute of Organic Chemistry, Russian Academy of Sciences, Leninsky prospekt 47, Moscow, 119991, Russia
| | - Evgeniy G Gordeev
- Zelinsky Institute of Organic Chemistry, Russian Academy of Sciences, Leninsky prospekt 47, Moscow, 119991, Russia
| | - Valentine P Ananikov
- Zelinsky Institute of Organic Chemistry, Russian Academy of Sciences, Leninsky prospekt 47, Moscow, 119991, Russia.
| |
Collapse
|
10
|
Mohammed ASA, Carino A, Testino A, Andalibi MR, Cervellino A. A dilute gold nanoparticle suspension as small-angle X-ray scattering standard for an absolute scale using an extended Guinier approximation. J Appl Crystallogr 2019. [DOI: 10.1107/s1600576719001109] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
In this article, a practical procedure for absolute intensity calibration for small-angle scattering (SAXS) studies on liquid microjets is established. A gold nanoparticle suspension is used as standard so that the intercept at Q = 0 of the SAXS scattering curve provides a scaling reference. In order to obtain the most precise extrapolation at Q = 0, an extension of the Guinier approximation has been used, with a second-order term in the fit that adapts to a larger Q range.
Collapse
|
11
|
Khaliqi K, Ghazal A, Azmi IDM, Amenitsch H, Mortensen K, Salentinig S, Yaghmur A. Direct monitoring of lipid transfer on exposure of citrem nanoparticles to an ethanol solution containing soybean phospholipids by combining synchrotron SAXS with microfluidics. Analyst 2017; 142:3118-3126. [PMID: 28744529 DOI: 10.1039/c7an00860k] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2023]
Abstract
Lipid exchange among citrem nanoparticles and an ethanol micellar solution containing soy phosphatidylcholine was investigated in situ by coupling small angle X-ray scattering with a microfluidic device. The produced soy phosphatidylcholine/citrem nanoparticles have great potential in the development of hemocompatible nanocarriers for drug delivery.
Collapse
Affiliation(s)
- K Khaliqi
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, DK-2100 Copenhagen Ø, Denmark.
| | | | | | | | | | | | | |
Collapse
|
12
|
Schiener A, Schmidt E, Bergmann C, Seifert S, Zahn D, Krach A, Weihrich R, Magerl A. The formation of CdS quantum dots and Au nanoparticles. Z KRIST-CRYST MATER 2017. [DOI: 10.1515/zkri-2016-1978] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Abstract
We report on microsecond-resolved in-situ SAXS experiments of the early nucleation and growth behavior of both cadmium sulfide (CdS) quantum dots in aqueous solution including the temperature dependence and of gold (Au) nanoparticles. A novel free-jet setup was developped to access reaction times as early as 20 μs. As the signal in particular in the beginning of the reaction is weak the containment-free nature of this sample environment prooved crucial. The SAXS data reveal a two-step pathway with a surprising stability of a structurally relaxed cluster with a diameter of about 2 nm. While these develop rapidly by ionic assembly, a further slower growth is attributed to cluster attachment. WAXS diffraction confirms, that the particles at this early stage are not yet crystalline. This growth mode is confirmed for a temperature range from 25°C to 45°C. An energy barrier for the diffusion of primary clusters in water of 0.60 eV was experimentally observed in agreement with molecular simulations. To access reaction times beyond 100 ms, a stopped-drop setup -again contaiment- free is introduced. SAXS experiments on the growth of Au nanoparticles on an extended time scale provide a much slower growth with one population only. Further, the influence of ionizing X-ray radiation on the Au particle fromation and growth is discussed.
Collapse
Affiliation(s)
- Andreas Schiener
- Crystallography and Structural Physics, Friedrich-Alexander University Erlangen-Nürnberg, Staudtstraße 3, 91058 Erlangen, Germany
| | - Ella Schmidt
- Crystallography and Structural Physics, Friedrich-Alexander University Erlangen-Nürnberg, Staudtstraße 3, 91058 Erlangen, Germany
| | - Christoph Bergmann
- Crystallography and Structural Physics, Friedrich-Alexander University Erlangen-Nürnberg, Staudtstraße 3, 91058 Erlangen, Germany
| | - Soenke Seifert
- X-Ray Science Division, Argonne National Laboratory, Advanced Photon Source, 9700 S. Cass Avenue, Lemont, IL 60439, USA
| | - Dirk Zahn
- Theoretical Chemistry and Computer-Chemistry-Center, Friedrich-Alexander University Erlangen-Nürnberg, Nägelsbachstraße 25, 91052 Erlangen, Germany
| | - Alexander Krach
- Inorganic Chemistry, University of Regensburg, Universitätsstraße 31, 93053 Regensburg, Germany
| | - Richard Weihrich
- Inorganic Chemistry, University of Regensburg, Universitätsstraße 31, 93053 Regensburg, Germany
- Institute for Materials Resource Management, University of Augsburg, Universitätsstr. 1, 86135 Augsburg, Germany
| | - Andreas Magerl
- Biophysics Goup, Center for Medical Physics and Technology, Friedrich-Alexander University Erlangen-Nürnberg, Henkestraße 91, 91052 Erlangen, Germany
| |
Collapse
|
13
|
Ghazal A, Lafleur JP, Mortensen K, Kutter JP, Arleth L, Jensen GV. Recent advances in X-ray compatible microfluidics for applications in soft materials and life sciences. LAB ON A CHIP 2016; 16:4263-4295. [PMID: 27731448 DOI: 10.1039/c6lc00888g] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
The increasingly narrow and brilliant beams at X-ray facilities reduce the requirements for both sample volume and data acquisition time. This creates new possibilities for the types and number of sample conditions that can be examined but simultaneously increases the demands in terms of sample preparation. Microfluidic-based sample preparation techniques have emerged as elegant alternatives that can be integrated directly into the experimental X-ray setup remedying several shortcomings of more traditional methods. We review the use of microfluidic devices in conjunction with X-ray measurements at synchrotron facilities in the context of 1) mapping large parameter spaces, 2) performing time resolved studies of mixing-induced kinetics, and 3) manipulating/processing samples in ways which are more demanding or not accessible on the macroscale. The review covers the past 15 years and focuses on applications where synchrotron data collection is performed in situ, i.e. directly on the microfluidic platform or on a sample jet from the microfluidic device. Considerations such as the choice of materials and microfluidic designs are addressed. The combination of microfluidic devices and measurements at large scale X-ray facilities is still emerging and far from mature, but it definitely offers an exciting array of new possibilities.
Collapse
Affiliation(s)
- Aghiad Ghazal
- Niels Bohr Institute, University of Copenhagen, Universitetsparken 5, DK-2100 Copenhagen, Denmark.
| | - Josiane P Lafleur
- Dept. of Pharmacy, University of Copenhagen, Universitetsparken 2, DK-2100 Copenhagen, Denmark
| | - Kell Mortensen
- Niels Bohr Institute, University of Copenhagen, Universitetsparken 5, DK-2100 Copenhagen, Denmark.
| | - Jörg P Kutter
- Dept. of Pharmacy, University of Copenhagen, Universitetsparken 2, DK-2100 Copenhagen, Denmark
| | - Lise Arleth
- Niels Bohr Institute, University of Copenhagen, Universitetsparken 5, DK-2100 Copenhagen, Denmark.
| | - Grethe V Jensen
- Niels Bohr Institute, University of Copenhagen, Universitetsparken 5, DK-2100 Copenhagen, Denmark.
| |
Collapse
|
14
|
Seiffert S. Microfluidics and Macromolecules: Top-Down Analytics and Bottom-Up Engineering of Soft Matter at Small Scales. MACROMOL CHEM PHYS 2016. [DOI: 10.1002/macp.201600280] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Sebastian Seiffert
- Johannes Gutenberg-Universität Mainz; Institute of Physical Chemistry; Duesbergweg 10-14 55128 Mainz Germany
| |
Collapse
|
15
|
Boken J, Soni SK, Kumar D. Microfluidic Synthesis of Nanoparticles and their Biosensing Applications. Crit Rev Anal Chem 2016; 46:538-61. [DOI: 10.1080/10408347.2016.1169912] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
16
|
Schwemmer F, Blanchet CE, Spilotros A, Kosse D, Zehnle S, Mertens HDT, Graewert MA, Rössle M, Paust N, Svergun DI, von Stetten F, Zengerle R, Mark D. LabDisk for SAXS: a centrifugal microfluidic sample preparation platform for small-angle X-ray scattering. LAB ON A CHIP 2016; 16:1161-1170. [PMID: 26931639 DOI: 10.1039/c5lc01580d] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
We present a centrifugal microfluidic LabDisk for protein structure analysis via small-angle X-ray scattering (SAXS) on synchrotron beamlines. One LabDisk prepares 120 different measurement conditions, grouped into six dilution matrices. Each dilution matrix: (1) features automatic generation of 20 different measurement conditions from three input liquids and (2) requires only 2.5 μl of protein solution, which corresponds to a tenfold reduction in sample volume in comparison to the state of the art. Total hands on time for preparation of 120 different measurement conditions is less than 5 min. Read-out is performed on disk within the synchrotron beamline P12 at EMBL Hamburg (PETRA III, DESY). We demonstrate: (1) aliquoting of 40 nl aliquots for five different liquids typically used in SAXS and (2) confirm fluidic performance of aliquoting, merging, mixing and read-out from SAXS experiments (2.7-4.4% CV of protein concentration). We apply the LabDisk for SAXS for basic analysis methods, such as measurement of the radius of gyration, and advanced analysis methods, such as the ab initio calculation of 3D models. The suitability of the LabDisk for SAXS for protein structure analysis under different environmental conditions is demonstrated for glucose isomerase under varying protein and NaCl concentrations. We show that the apparent radius of gyration of the negatively charged glucose isomerase decreases with increasing protein concentration at low salt concentration. At high salt concentration the radius of gyration (Rg) does not change with protein concentrations. Such experiments can be performed by a non-expert, since the LabDisk for SAXS does not require attachment of tubings or pumps and can be filled with regular pipettes. The new platform has the potential to introduce routine high-throughput SAXS screening of protein structures with minimal input volumes to the regular operation of synchrotron beamlines.
Collapse
Affiliation(s)
- Frank Schwemmer
- Laboratory for MEMS Applications, IMTEK - Department of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany.
| | - Clement E Blanchet
- European Molecular Biology Laboratory, Hamburg Outstation, Notkestrasse 85, Hamburg, 22603, Germany
| | - Alessandro Spilotros
- European Molecular Biology Laboratory, Hamburg Outstation, Notkestrasse 85, Hamburg, 22603, Germany
| | - Dominique Kosse
- Hahn-Schickard - Georges-Koehler-Allee 103, 79110 Freiburg, Germany
| | - Steffen Zehnle
- Hahn-Schickard - Georges-Koehler-Allee 103, 79110 Freiburg, Germany
| | - Haydyn D T Mertens
- European Molecular Biology Laboratory, Hamburg Outstation, Notkestrasse 85, Hamburg, 22603, Germany
| | - Melissa A Graewert
- European Molecular Biology Laboratory, Hamburg Outstation, Notkestrasse 85, Hamburg, 22603, Germany
| | - Manfred Rössle
- European Molecular Biology Laboratory, Hamburg Outstation, Notkestrasse 85, Hamburg, 22603, Germany
| | - Nils Paust
- Laboratory for MEMS Applications, IMTEK - Department of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany. and Hahn-Schickard - Georges-Koehler-Allee 103, 79110 Freiburg, Germany
| | - Dmitri I Svergun
- European Molecular Biology Laboratory, Hamburg Outstation, Notkestrasse 85, Hamburg, 22603, Germany
| | - Felix von Stetten
- Laboratory for MEMS Applications, IMTEK - Department of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany. and Hahn-Schickard - Georges-Koehler-Allee 103, 79110 Freiburg, Germany
| | - Roland Zengerle
- Laboratory for MEMS Applications, IMTEK - Department of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany. and Hahn-Schickard - Georges-Koehler-Allee 103, 79110 Freiburg, Germany and BIOSS Centre for Biological Signalling Studies, University of Freiburg, 79110 Freiburg, Germany
| | - Daniel Mark
- Hahn-Schickard - Georges-Koehler-Allee 103, 79110 Freiburg, Germany
| |
Collapse
|
17
|
Schiener A, Seifert S, Magerl A. The stopped-drop method: a novel setup for containment-free and time-resolved measurements. JOURNAL OF SYNCHROTRON RADIATION 2016; 23:545-550. [PMID: 26917142 DOI: 10.1107/s1600577515023826] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2015] [Accepted: 12/10/2015] [Indexed: 06/05/2023]
Abstract
A novel setup for containment-free time-resolved experiments at a free-hanging drop is reported. Within a dead-time of 100 ms a drop of mixed reactant solutions is formed and the time evolution of a reaction can be followed from thereon by various techniques. As an example, a small-angle X-ray scattering study on the formation mechanism of EDTA-stabilized CdS both at a synchrotron and a laboratory X-ray source is presented here. While the evolution can be followed with one drop only at a synchrotron source, a stroboscopic mode with many drops is preferable for the laboratory source.
Collapse
Affiliation(s)
- Andreas Schiener
- Physics Department, Friedrich-Alexander University of Erlangen-Nürnberg, Staudtstraße 3, Erlangen 91058, Germany
| | - Soenke Seifert
- X-ray Science Division, Argonne National Laboratory, 9700 South Cass Avenue, Lemont, IL 60439, USA
| | - Andreas Magerl
- Physics Department, Friedrich-Alexander University of Erlangen-Nürnberg, Staudtstraße 3, Erlangen 91058, Germany
| |
Collapse
|
18
|
Kügler RT, Doyle S, Kind M. Fundamental insights into barium sulfate precipitation by time-resolved in situ synchrotron radiation wide-angle X-ray scattering (WAXS). Chem Eng Sci 2015. [DOI: 10.1016/j.ces.2014.12.024] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
19
|
Schiener A, Magerl A, Krach A, Seifert S, Steinrück HG, Zagorac J, Zahn D, Weihrich R. In situ investigation of two-step nucleation and growth of CdS nanoparticles from solution. NANOSCALE 2015; 7:11328-11333. [PMID: 26067094 DOI: 10.1039/c5nr01602a] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
We report on a combined ultra-fast in situ SAXS and WAXS study along a free-jet providing insight into the evolution of the morphology and crystalline structure of CdS quantum dots in the very early stage of nucleation between 100 μs and 2.5 ms with a time resolution down to 10 μs. Accessing this yet unexplored time regime provides direct evidence of a two-step mechanism via formation of prenucleation clusters followed by nanoparticle nucleation from coalescing precursors. Using ab initio calculations, the latter species is identified as Cd13S4(SH)18 clusters, the stability of which results from a compact surface and inner structure.
Collapse
Affiliation(s)
- A Schiener
- Crystallography and Structural Physics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Department of Physics, Staudtstraße 3, 91058 Erlangen, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Schoenitz M, Grundemann L, Augustin W, Scholl S. Fouling in microstructured devices: a review. Chem Commun (Camb) 2015; 51:8213-28. [PMID: 25750979 DOI: 10.1039/c4cc07849g] [Citation(s) in RCA: 107] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Microstructured devices are widely used for manufacturing products that benefit from process intensification, with pharmaceutical products or specialties of the chemical industry being prime examples. These devices are ideally used for processing pure fluids. Where particulate or non-pure flows are involved, processes are treated with utmost caution since related fouling and blocking issues present the greatest barrier to operating microstructured devices effectively. Micro process engineering is a relatively new research field and there is limited understanding of fouling in these dimensions and its underlying processes and phenomena. A comprehensive review on fouling in microstructured devices would be helpful in this regard, but is currently lacking. This paper attempts to review recent developments of fouling in micro dimensions for all fouling categories (crystallization, particulate, chemical reaction, corrosion and biological growth fouling) and the sequential events involved (initiation, transport, attachment, removal and aging). Compared to fouling in macro dimensions, an additional sixth category is suggested: clogging by gas bubbles. Most of the reviewed papers present very specific fouling investigations making it difficult to derive general rules and parameter dependencies, and comparative or critical considerations of the studies were difficult. We therefore used a statistical approach to evaluate the research in the field of fouling in microchannels.
Collapse
Affiliation(s)
- M Schoenitz
- Institute for Chemical and Thermal Process Engineering, Technische Universität Braunschweig, Langer Kamp 7, Braunschweig, Germany.
| | | | | | | |
Collapse
|
21
|
Fernandes DLA, Pavliuk MV, Sá J. A 3D printed microliquid jet with an adjustable nozzle diameter. Analyst 2015; 140:6234-8. [DOI: 10.1039/c5an01329a] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Microliquid jets have many applications, in particular in the fields of spectroscopy/analysis of samples susceptible to beam damage.
Collapse
Affiliation(s)
| | - M. V. Pavliuk
- Department of Chemistry
- Ångström Laboratory
- Uppsala University
- Sweden
| | - J. Sá
- Department of Chemistry
- Ångström Laboratory
- Uppsala University
- Sweden
- Institute of Physical Chemistry
| |
Collapse
|
22
|
Völkle CM, Gebauer D, Cölfen H. High-resolution insights into the early stages of silver nucleation and growth. Faraday Discuss 2015; 179:59-77. [DOI: 10.1039/c4fd00269e] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Nucleation and growth of silver nanoparticles has already been investigated with various experimental and computational tools. However, owing to inherent problems associated with the analytical characterization of nucleation processes, there is a general lack of experimental data regarding the earliest precursors and smallest Ag(0) clusters. Here, we address this problem by the application of Synthetic Boundary Crystallization Ultracentrifugation, utilizing a multiwavelength detector for the first time, complemented by a specialized titration assay. These techniques shed new light on silver nanoparticle precursors existing in the pre-nucleation regime, and the initially nucleated ensemble of nanoclusters. For the first time, we present experimental data of UV-Vis spectra for fractionated silver clusters. These allow for unsurpassed insights into the sequence of nucleation and early growth species as well as their optical properties.
Collapse
Affiliation(s)
- Cornelia M. Völkle
- Department of Chemistry
- Physical Chemistry
- University of Konstanz
- Universitätsstr. 10
- D-78457 Konstanz
| | - Denis Gebauer
- Department of Chemistry
- Physical Chemistry
- University of Konstanz
- Universitätsstr. 10
- D-78457 Konstanz
| | - Helmut Cölfen
- Department of Chemistry
- Physical Chemistry
- University of Konstanz
- Universitätsstr. 10
- D-78457 Konstanz
| |
Collapse
|
23
|
Witala M, Han J, Menzel A, Nygård K. In situsmall-angle X-ray scattering characterization of X-ray-induced local heating. J Appl Crystallogr 2014. [DOI: 10.1107/s1600576714020159] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
It is shown that small-angle X-ray scattering from binary liquid mixtures close to the critical point of demixing can be used forin situcharacterization of beam-induced heating of liquid samples. For demonstration purposes, the proposed approach is applied on a well studied critical mixture of water and 2,6-lutidine. Given a typical incident X-ray flux at a third-generation synchrotron light source and using a 1.5 mm-diameter glass capillary as sample container, a beam-induced local temperature increase of 0.45 ± 0.10 K is observed.
Collapse
|
24
|
Trebbin M, Krüger K, DePonte D, Roth SV, Chapman HN, Förster S. Microfluidic liquid jet system with compatibility for atmospheric and high-vacuum conditions. LAB ON A CHIP 2014; 14:1733-45. [PMID: 24671443 DOI: 10.1039/c3lc51363g] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
We present microfluidic chip based devices that produce liquid jets with micrometer diameters while operating at very low flow rates. The chip production is based on established soft-lithographical techniques employing a three-layer design protocol. This allows the exact, controlled and reproducible design of critical parts such as nozzles and the production of nozzle arrays. The microfluidic chips reproducibly generate liquid jets exiting at perfect right angles with diameters between 20 μm and 2 μm, and under special circumstances, even down to 0.9 μm. Jet diameter, jet length, and the domain of the jetting/dripping instability can be predicted and controlled based on the theory for liquid jets in the plate-orifice configuration described by Gañán-Calvo et al. Additionally, conditions under which the device produces highly reproducible monodisperse droplets at exact and predictable rates can be achieved. The devices operate under atmospheric and under vacuum conditions making them highly relevant for a wide range of applications, for example, for free-electron lasers. Further, the straightforward integration of additional features such as a jet-in-jet is demonstrated. This device design has the potential to integrate more features based on established microfluidic components and may become a standard device for small liquid jet production.
Collapse
Affiliation(s)
- Martin Trebbin
- Physical Chemistry 1, University of Bayreuth, Universitätsstraße 30, 95447 Bayreuth, Germany.
| | | | | | | | | | | |
Collapse
|
25
|
Rose AL, Bligh MW, Collins R, Waite TD. Resolving early stages of homogeneous iron(III) oxyhydroxide formation from iron(III) nitrate solutions at pH 3 using time-resolved SAXS. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2014; 30:3548-56. [PMID: 24601665 PMCID: PMC3974613 DOI: 10.1021/la404712r] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2013] [Revised: 03/06/2014] [Indexed: 05/26/2023]
Abstract
Small angle X-ray scattering (SAXS) measurements coupled to a stopped-flow device has permitted the observation of the kinetics of Fe(III) oxyhydroxide (FeOx) formation and transformation from around 1 s to 30 min after initiation under environmentally relevant conditions at pH 3. The Unified Model approach was used to determine the evolution of multiple key parameters (particle scattering mass, mean particle volume, particle concentration, particle dimensionality, and particle size) for two separate structural levels as a function of time, with the results obtained enabling clarification of the mechanisms underlying FeOx formation and transformation under these conditions. Colloidal primary particles (radius of gyration 2-10 nm) that were observable by SAXS formed within 1 s of stopping the flow and subsequently grew over several minutes, first by cluster-cluster addition and then by a monomer-addition mechanism. Aggregation of these primary particles via a secondary cluster-cluster addition mechanism simultaneously resulted in a distinct population of larger (25-40 nm radius of gyration) secondary particles. The primary particles evolved into compact spheroidal forms with fractally rough surfaces, while the secondary particles were relatively open mass fractal structures. Comparison of the observed rates of these processes with those predicted for Fe polymerization indicates that kinetics of primary particle formation were likely controlled initially by rates of exchange between water molecules coordinated with Fe and those in the bulk solution. These findings provide new insights into the mechanisms underlying FeOx formation and transformation, and the kinetics of these mechanisms, at pH 3.
Collapse
Affiliation(s)
- Andrew L. Rose
- Southern
Cross GeoScience, Southern Cross University, Lismore 2480, Australia
- UNSW
Water Research Centre, The University of
New South Wales, Sydney 2052, Australia
| | - Mark W. Bligh
- UNSW
Water Research Centre, The University of
New South Wales, Sydney 2052, Australia
- School
of Civil and Environmental Engineering, The University of New South Wales, Sydney 2052, Australia
| | - Richard
N. Collins
- UNSW
Water Research Centre, The University of
New South Wales, Sydney 2052, Australia
- School
of Civil and Environmental Engineering, The University of New South Wales, Sydney 2052, Australia
| | - T. David Waite
- UNSW
Water Research Centre, The University of
New South Wales, Sydney 2052, Australia
- School
of Civil and Environmental Engineering, The University of New South Wales, Sydney 2052, Australia
| |
Collapse
|
26
|
Körstgens V, Philipp M, Magerl D, Niedermeier MA, Santoro G, Roth SV, Müller-Buschbaum P. Following initial changes in nanoparticle films under laminar flow conditions with in situ GISAXS microfluidics. RSC Adv 2014. [DOI: 10.1039/c3ra44554b] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
27
|
Marmiroli B, Cacho-Nerin F, Sartori B, Pérez J, Amenitsch H. Thorough small-angle X-ray scattering analysis of the instability of liquid micro-jets in air. JOURNAL OF SYNCHROTRON RADIATION 2014; 21:193-202. [PMID: 24365936 DOI: 10.1107/s1600577513027951] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2013] [Accepted: 10/11/2013] [Indexed: 06/03/2023]
Abstract
Liquid jets are of interest, both for their industrial relevance and for scientific applications (more important, in particular for X-rays, after the advent of free-electron lasers that require liquid jets as sample carrier). Instability mechanisms have been described theoretically and by numerical simulation, but confirmed by few experimental techniques. In fact, these are mainly based on cameras, which is limited by the imaging resolution, and on light scattering, which is hindered by absorption, reflection, Mie scattering and multiple scattering due to complex air/liquid interfaces during jet break-up. In this communication it is demonstrated that synchrotron small-angle X-ray scattering (SAXS) can give quantitative information on liquid jet dynamics at the nanoscale, by detecting time-dependent morphology and break-up length. Jets ejected from circular tubes of different diameters (100-450 µm) and speeds (0.7-21 m s(-1)) have been explored to cover the Rayleigh and first wind-induced regimes. Various solvents (water, ethanol, 2-propanol) and their mixtures have been examined. The determination of the liquid jet behaviour becomes essential, as it provides background data in subsequent studies of chemical and biological reactions using SAXS or X-ray diffraction based on synchrotron radiation and free-electron lasers.
Collapse
Affiliation(s)
- Benedetta Marmiroli
- Institute of Inorganic Chemistry, Graz University of Technology, Stremayrgasse 9/IV, Graz 8010, Austria
| | - Fernando Cacho-Nerin
- Institute of Inorganic Chemistry, Graz University of Technology, Stremayrgasse 9/IV, Graz 8010, Austria
| | - Barbara Sartori
- Institute of Inorganic Chemistry, Graz University of Technology, Stremayrgasse 9/IV, Graz 8010, Austria
| | - Javier Pérez
- Beamline SWING, Synchrotron SOLEIL, L'Orme des Merisiers, Saint-Aubin, BP 48, 91192 Gif sur Yvette, France
| | - Heinz Amenitsch
- Institute of Inorganic Chemistry, Graz University of Technology, Stremayrgasse 9/IV, Graz 8010, Austria
| |
Collapse
|
28
|
Jain R, Petri M, Kirschbaum S, Feindt H, Steltenkamp S, Sonnenkalb S, Becker S, Griesinger C, Menzel A, Burg TP, Techert S. X-ray scattering experiments with high-flux X-ray source coupled rapid mixing microchannel device and their potential for high-flux neutron scattering investigations. THE EUROPEAN PHYSICAL JOURNAL. E, SOFT MATTER 2013; 36:109. [PMID: 24092048 DOI: 10.1140/epje/i2013-13109-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2012] [Revised: 12/13/2012] [Accepted: 07/26/2013] [Indexed: 06/02/2023]
Abstract
Small-angle X-ray scattering provides global, shape-sensitive structural information about macromolecules in solution. Its extension to time dimension in the form of time-resolved SAXS investigations and combination with other time-resolved biophysical methods contributes immensely to the study of protein dynamics. TR-SAXS can also provide unique information about the global structures of transient intermediates during protein dynamics. An experimental set-up with low protein consumption is essential for an extensive use of TR-SAXS experiments on protein dynamics. In this direction, a newly developed 20-microchannel microfluidic continuous-flow mixer was combined with SAXS. With this set-up, we demonstrate ubiquitin unfolding dynamics after rapid mixing with the chaotropic agent Guanidinium-HCl within milliseconds using only ∼ 40 nanoliters of the protein sample per scattering image. It is suggested that, in the future, this new TR-SAXS platform will help to increase the use of time-resolved small-angle X-ray scattering, wide-angle X-ray scattering and neutron scattering experiments for studying protein dynamics in the early millisecond regime. The potential research field for this set-up includes protein folding, protein misfolding, aggregation in amyloidogenic diseases, function of intrinsically disordered proteins and various protein-ligand interactions.
Collapse
Affiliation(s)
- R Jain
- Structural Dynamics of (Bio)chemical Systems, MPI-BPC, Am Fassberg 11, 37077, Goettingen, Germany
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
29
|
Stehle R, Goerigk G, Wallacher D, Ballauff M, Seiffert S. Small-angle X-ray scattering in droplet-based microfluidics. LAB ON A CHIP 2013; 13:1529-1537. [PMID: 23429654 DOI: 10.1039/c3lc41291a] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Small-angle X-ray scattering (SAXS) is a powerful technique to probe nanometer-scale structures; a particularly powerful implementation of SAXS is to apply it to continuously flowing liquid samples in microfluidic devices. This approach has been employed extensively, but virtually all existing studies rely on the use of one-phase microfluidics. We overcome this limitation and present the combination of SAXS with multiphase, droplet-based microfluidics to establish a platform methodology. We focus on the use of two different classes of microfluidic devices in two different approaches. In one approach, we use silicone elastomer devices to form water-in-oil emulsion droplets that contain gold nanoparticles as a model analyte. The emulsion droplets serve as nanoliter-scale compartments that are probed by SAXS off the microfluidic chip. In another approach, we both create and probe the droplets on the same microfluidic chip. In this case, we use a glass microcapillary device that serves to form gold nanoparticles in situ by mixing two aqueous precursor fluids within the drops. Both approaches allow the gold-nanoparticle scattering to be straightforwardly isolated from the raw data; subsequent fitting yields quantitative information on the size, shape, and concentration of the nanoparticles within the compartmentalizing emulsion droplets. In addition, the microfluidic flow parameters scale with the scattering cross-sections in a quantitative fashion. These results foreshadow the utility of this technique for other, more sophisticated tasks such as single-protein analysis or automated assaying.
Collapse
Affiliation(s)
- Ralf Stehle
- Helmholtz-Zentrum Berlin, Institute Soft Matter and Functional Materials, Hahn-Meitner-Platz 1, D-14109 Berlin, Germany
| | | | | | | | | |
Collapse
|
30
|
Yue J, Schouten JC, Nijhuis TA. Integration of Microreactors with Spectroscopic Detection for Online Reaction Monitoring and Catalyst Characterization. Ind Eng Chem Res 2012. [DOI: 10.1021/ie301258j] [Citation(s) in RCA: 84] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Jun Yue
- Laboratory of Chemical Reactor Engineering, Department of Chemical Engineering and Chemistry, Eindhoven University of Technology,
P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Jaap C. Schouten
- Laboratory of Chemical Reactor Engineering, Department of Chemical Engineering and Chemistry, Eindhoven University of Technology,
P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - T. Alexander Nijhuis
- Laboratory of Chemical Reactor Engineering, Department of Chemical Engineering and Chemistry, Eindhoven University of Technology,
P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| |
Collapse
|
31
|
Marmiroli B, Amenitsch H. X-ray lithography and small-angle X-ray scattering: a combination of techniques merging biology and materials science. EUROPEAN BIOPHYSICS JOURNAL: EBJ 2012; 41:851-61. [PMID: 22854870 DOI: 10.1007/s00249-012-0843-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2012] [Revised: 06/30/2012] [Accepted: 07/10/2012] [Indexed: 11/28/2022]
Abstract
The advent of micro/nanotechnology has blurred the border between biology and materials science. Miniaturization of chemical and biological assays, performed by use of micro/nanofluidics, requires both careful selection of the methods of fabrication and the development of materials designed for specific applications. This, in turn, increases the need for interdisciplinary combination of suitable microfabrication and characterisation techniques. In this review, the advantages of combining X-ray lithography, as fabrication technique, with small-angle X-ray scattering measurements will be discussed. X-ray lithography enables the limitations of small-angle X-ray scattering, specifically time resolution and sample environment, to be overcome. Small-angle X-ray scattering, on the other hand, enables investigation and, consequently, adjustment of the nanostructural morphology of microstructures and materials fabricated by X-ray lithography. Moreover, the effect of X-ray irradiation on novel materials can be determined by use of small-angle X-ray scattering. The combination of top-down and bottom-up methods to develop new functional materials and structures with potential in biology will be reported.
Collapse
Affiliation(s)
- B Marmiroli
- Institute of Biophysics and Nanosystems Research, Austrian Academy of Sciences, Schmiedlstr. 6, 8042, Graz, Austria
| | | |
Collapse
|
32
|
Structural characterization of lipidic systems under nonequilibrium conditions. EUROPEAN BIOPHYSICS JOURNAL: EBJ 2012; 41:831-40. [PMID: 22569535 DOI: 10.1007/s00249-012-0815-7] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2012] [Revised: 03/27/2012] [Accepted: 04/15/2012] [Indexed: 12/31/2022]
Abstract
This review covers recent studies on the characterization of the dynamics of lipidic nanostructures formed via self-assembly processes. The focus is placed on two main topics: First, an overview of advanced experimental small-angle X-ray scattering (SAXS) setups combined with various sample manipulation techniques including, for instance, stop-flow mixing or rapid temperature-jump perturbation is given. Second, our recent synchrotron SAXS findings on the dynamic structural response of gold nanoparticle-loaded vesicles upon exposure to an ultraviolet light source, the impact of rapidly mixing negatively charged vesicles with calcium ions, and in situ hydration-induced formation of inverted-type liquid-crystalline phases loaded with the local anesthetic bupivacaine are summarized. These in situ time-resolved experiments allow real-time monitoring of the dynamics of the structural changes and the possible formation of intermediate states in the millisecond to second range. The need for investigating self-assembled systems, mainly stimuli-responsive drug nanocarriers, under nonequilibrium conditions is discussed. For pharmaceutically relevant applications, it is essential to combine these investigations with appropriate in vitro and in vivo studies.
Collapse
|
33
|
Lafleur JP, Snakenborg D, Nielsen SS, Møller M, Toft KN, Menzel A, Jacobsen JK, Vestergaard B, Arleth L, Kutter JP. Automated microfluidic sample-preparation platform for high-throughput structural investigation of proteins by small-angle X-ray scattering. J Appl Crystallogr 2011. [DOI: 10.1107/s0021889811030068] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
A new microfluidic sample-preparation system is presented for the structural investigation of proteins using small-angle X-ray scattering (SAXS) at synchrotrons. The system includes hardware and software features for precise fluidic control, sample mixing by diffusion, automated X-ray exposure control, UV absorbance measurements and automated data analysis. As little as 15 µl of sample is required to perform a complete analysis cycle, including sample mixing, SAXS measurement, continuous UV absorbance measurements, and cleaning of the channels and X-ray cell with buffer. The complete analysis cycle can be performed in less than 3 min. Bovine serum albumin was used as a model protein to characterize the mixing efficiency and sample consumption of the system. The N2 fragment of an adaptor protein (p120-RasGAP) was used to demonstrate how the device can be used to survey the structural space of a protein by screening a wide set of conditions using high-throughput techniques.
Collapse
|
34
|
|
35
|
Verch A, Gebauer D, Antonietti M, Cölfen H. How to control the scaling of CaCO3: a “fingerprinting technique” to classify additives. Phys Chem Chem Phys 2011; 13:16811-20. [DOI: 10.1039/c1cp21328h] [Citation(s) in RCA: 87] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
36
|
Abstract
The application of microfluidics in chemistry has gained significant importance in the recent years. Miniaturized chemistry platforms provide controlled fluid transport, rapid chemical reactions, and cost-saving advantages over conventional reactors. The advantages of microfluidics have been clearly established in the field of analytical and bioanalytical sciences and in the field of organic synthesis. It is less true in the field of inorganic chemistry and materials science; however in inorganic chemistry it has mostly been used for the separation and selective extraction of metal ions. Microfluidics has been used in materials science mainly for the improvement of nanoparticle synthesis, namely metal, metal oxide, and semiconductor nanoparticles. Microfluidic devices can also be used for the formulation of more advanced and sophisticated inorganic materials or hybrids.
Collapse
Affiliation(s)
- Ali Abou-Hassan
- UPMC Univ Paris 06, UMR 7195 PECSA, Physicochimie des Electrolytes, Colloïdes, Sciences Analytiques, 75005 Paris, France.
| | | | | |
Collapse
|
37
|
Abécassis B, Testard F, Kong Q, Francois B, Spalla O. Influence of monomer feeding on a fast gold nanoparticles synthesis: time-resolved XANES and SAXS experiments. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2010; 26:13847-13854. [PMID: 20704344 DOI: 10.1021/la1020274] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
A comprehensive study of the mechanism of gold nanoparticle formation has been conducted using third-generation synchrotrons. The particles were obained by reduction of AuCl(3) by BH(4)(-) in toluene. Gold oxidation state was monitored by X-ray absorption near edge spectroscopy (XANES), while the size and concentration of the nanoparticles were assessed by small-angle X-ray scattering (SAXS). A time-resolution of 100 ms has been achieved for a total formation time of a few seconds. The change with time of the total amount of Au(0) present in the solution is obtained by XANES. The change of the amount of Au(0) inside the nanoparticles is obtained from the SAXS signal. The comparison between these two quantities shows that a measurable amount of Au(0) exists transiently as monomers (or very small entities) in solution and this quantity is linked to an observed burst of nucleation of nanoparticles. The reduction kinetics is strongly influenced by the presence of ligands and a change in temperature. A model coupling the observed reduction kinetics and nucleation and growth laws is able to recover the final size and number densities of the explored experimental conditions.
Collapse
Affiliation(s)
- Benjamin Abécassis
- CEA Saclay, DSM/IRAMIS/UMR 3299 CEA/CNRS SIS2M/Laboratoire Interdisciplinaire surl'Organisation Nanométrique et Supramoléculaire, 91191 Gif sur Yvette, France
| | | | | | | | | |
Collapse
|
38
|
|
39
|
Arora A, Simone G, Salieb-Beugelaar GB, Kim JT, Manz A. Latest Developments in Micro Total Analysis Systems. Anal Chem 2010; 82:4830-47. [PMID: 20462185 DOI: 10.1021/ac100969k] [Citation(s) in RCA: 267] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Arun Arora
- KIST Europe, Korea Institute of Science and Technology, Campus E71, 66123 Saarbrücken, Germany, FRIAS, Freiburg Institute for Advanced Studies, Albert-Ludwigs-Universität Freiburg, Albertstrasse 19, 79104 Freiburg, Germany, IMTEK, Institute for Microsystem Technology, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany, and MESA+ Institute for Nanotechnology/Lab-on-a-Chip Group, Twente University, Building Carré, 7500 AE, Enschede, The Netherlands
| | - Giuseppina Simone
- KIST Europe, Korea Institute of Science and Technology, Campus E71, 66123 Saarbrücken, Germany, FRIAS, Freiburg Institute for Advanced Studies, Albert-Ludwigs-Universität Freiburg, Albertstrasse 19, 79104 Freiburg, Germany, IMTEK, Institute for Microsystem Technology, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany, and MESA+ Institute for Nanotechnology/Lab-on-a-Chip Group, Twente University, Building Carré, 7500 AE, Enschede, The Netherlands
| | - Georgette B. Salieb-Beugelaar
- KIST Europe, Korea Institute of Science and Technology, Campus E71, 66123 Saarbrücken, Germany, FRIAS, Freiburg Institute for Advanced Studies, Albert-Ludwigs-Universität Freiburg, Albertstrasse 19, 79104 Freiburg, Germany, IMTEK, Institute for Microsystem Technology, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany, and MESA+ Institute for Nanotechnology/Lab-on-a-Chip Group, Twente University, Building Carré, 7500 AE, Enschede, The Netherlands
| | - Jung Tae Kim
- KIST Europe, Korea Institute of Science and Technology, Campus E71, 66123 Saarbrücken, Germany, FRIAS, Freiburg Institute for Advanced Studies, Albert-Ludwigs-Universität Freiburg, Albertstrasse 19, 79104 Freiburg, Germany, IMTEK, Institute for Microsystem Technology, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany, and MESA+ Institute for Nanotechnology/Lab-on-a-Chip Group, Twente University, Building Carré, 7500 AE, Enschede, The Netherlands
| | - Andreas Manz
- KIST Europe, Korea Institute of Science and Technology, Campus E71, 66123 Saarbrücken, Germany, FRIAS, Freiburg Institute for Advanced Studies, Albert-Ludwigs-Universität Freiburg, Albertstrasse 19, 79104 Freiburg, Germany, IMTEK, Institute for Microsystem Technology, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany, and MESA+ Institute for Nanotechnology/Lab-on-a-Chip Group, Twente University, Building Carré, 7500 AE, Enschede, The Netherlands
| |
Collapse
|
40
|
Schmidt W, Bussian P, Lindén M, Amenitsch H, Agren P, Tiemann M, Schüth F. Accessing Ultrashort Reaction Times in Particle Formation with SAXS Experiments: ZnS Precipitation on the Microsecond Time Scale. J Am Chem Soc 2010; 132:6822-6. [DOI: 10.1021/ja101519z] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Wolfgang Schmidt
- Max-Planck-Institut für Kohlenforschung, Kaiser-Wilhelm-Platz 1, D-45470 Mülheim an der Ruhr, Germany, Center for Functional Materials, Department of Physical Chemistry, Åbo Akademi University, Porthansgatan 3-5, FIN-20500 Turku, Finland, Institute of Biophysics and Nanosystems Research, Austrian Academy of Sciences, Schmiedlstr. 6, A-8042 Graz, Austria
| | - Patrick Bussian
- Max-Planck-Institut für Kohlenforschung, Kaiser-Wilhelm-Platz 1, D-45470 Mülheim an der Ruhr, Germany, Center for Functional Materials, Department of Physical Chemistry, Åbo Akademi University, Porthansgatan 3-5, FIN-20500 Turku, Finland, Institute of Biophysics and Nanosystems Research, Austrian Academy of Sciences, Schmiedlstr. 6, A-8042 Graz, Austria
| | - Mika Lindén
- Max-Planck-Institut für Kohlenforschung, Kaiser-Wilhelm-Platz 1, D-45470 Mülheim an der Ruhr, Germany, Center for Functional Materials, Department of Physical Chemistry, Åbo Akademi University, Porthansgatan 3-5, FIN-20500 Turku, Finland, Institute of Biophysics and Nanosystems Research, Austrian Academy of Sciences, Schmiedlstr. 6, A-8042 Graz, Austria
| | - Heinz Amenitsch
- Max-Planck-Institut für Kohlenforschung, Kaiser-Wilhelm-Platz 1, D-45470 Mülheim an der Ruhr, Germany, Center for Functional Materials, Department of Physical Chemistry, Åbo Akademi University, Porthansgatan 3-5, FIN-20500 Turku, Finland, Institute of Biophysics and Nanosystems Research, Austrian Academy of Sciences, Schmiedlstr. 6, A-8042 Graz, Austria
| | - Patrik Agren
- Max-Planck-Institut für Kohlenforschung, Kaiser-Wilhelm-Platz 1, D-45470 Mülheim an der Ruhr, Germany, Center for Functional Materials, Department of Physical Chemistry, Åbo Akademi University, Porthansgatan 3-5, FIN-20500 Turku, Finland, Institute of Biophysics and Nanosystems Research, Austrian Academy of Sciences, Schmiedlstr. 6, A-8042 Graz, Austria
| | - Michael Tiemann
- Max-Planck-Institut für Kohlenforschung, Kaiser-Wilhelm-Platz 1, D-45470 Mülheim an der Ruhr, Germany, Center for Functional Materials, Department of Physical Chemistry, Åbo Akademi University, Porthansgatan 3-5, FIN-20500 Turku, Finland, Institute of Biophysics and Nanosystems Research, Austrian Academy of Sciences, Schmiedlstr. 6, A-8042 Graz, Austria
| | - Ferdi Schüth
- Max-Planck-Institut für Kohlenforschung, Kaiser-Wilhelm-Platz 1, D-45470 Mülheim an der Ruhr, Germany, Center for Functional Materials, Department of Physical Chemistry, Åbo Akademi University, Porthansgatan 3-5, FIN-20500 Turku, Finland, Institute of Biophysics and Nanosystems Research, Austrian Academy of Sciences, Schmiedlstr. 6, A-8042 Graz, Austria
| |
Collapse
|
41
|
Polte J, Erler R, Thünemann AF, Emmerling F, Kraehnert R. SAXS in combination with a free liquid jet for improved time-resolved in situ studies of the nucleation and growth of nanoparticles. Chem Commun (Camb) 2010; 46:9209-11. [DOI: 10.1039/c0cc03238g] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|