1
|
Bedi N, Srivastava DK, Srivastava A, Mahapatra S, Dkhar DS, Chandra P, Srivastava A. Marine Biological Macromolecules as Matrix Material for Biosensor fabrication. Biotechnol Bioeng 2022; 119:2046-2063. [PMID: 35470439 DOI: 10.1002/bit.28122] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 04/19/2022] [Accepted: 04/23/2022] [Indexed: 11/06/2022]
Abstract
The Ocean covers two-third of our planet and has great biological heterogeneity. Marine organisms like algae, vertebrates, invertebrates, and microbes are known to provide many natural products with biological activities as well as potent sources of biomaterials for therapeutic, biomedical, biosensors, and climate stabilization. Over the years, the field of biosensors have gained huge attention due to their extraordinary ability to provide early disease diagnosis, rapid detection of various molecules and substances along with long term monitoring. This review aims to focus on the properties and employment of various biomaterials (Carbohydrate polymers, proteins, polyacids etc) of marine origin such as Alginate, Chitin, Chitosan, Fucoidan, Carrageenan, Chondroitin Sulfate (CS), Hyaluronic acid (HA), Collagen, marine pigments, marine nanoparticles, Hydroxyapatite (HAp), Biosilica, lectins, and marine whole cell in the design and development of biosensors. Further, this review also covers the source of such marine biomaterials and their promising evolution in the fabrication of biosensors that are potent to be employed in the biomedical, environmental science and agricultural sciences domains. The use of such fabricated biosensors harness the system with excellent specificity, selectivity, biocompatibility, thermally stable and minimal cost advantages. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Namita Bedi
- Amity Institute of Biotechnology, Amity University Uttar Pradesh, Sector 125, Noida, India
| | | | - Arti Srivastava
- Amity Institute of Biotechnology, Amity University Uttar Pradesh, Sector 125, Noida, India
| | - Supratim Mahapatra
- Laboratory of Bio-Physio Sensors and Nanobiotechnology, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, Uttar Pradesh, India
| | - Daphika S Dkhar
- Laboratory of Bio-Physio Sensors and Nanobiotechnology, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, Uttar Pradesh, India
| | - Pranjal Chandra
- Laboratory of Bio-Physio Sensors and Nanobiotechnology, School of Biochemical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, Uttar Pradesh, India
| | - Ashutosh Srivastava
- Amity Institute of Biotechnology, Amity University Uttar Pradesh, Sector 125, Noida, India.,Amity Institute of Marine Science and Technology, Amity University Uttar Pradesh, Sector 125, Noida, India
| |
Collapse
|
2
|
Tummalapalli M, Singh S, Sanwaria S, Gurave PM. Design and development of advanced glucose biosensors via tuned interactions between marine polysaccharides and diagnostic elements – A survey. SENSORS INTERNATIONAL 2022. [DOI: 10.1016/j.sintl.2022.100170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
3
|
Chen H, Zhang H, Xu T, Yu J. An Overview of Micronanoswarms for Biomedical Applications. ACS NANO 2021; 15:15625-15644. [PMID: 34647455 DOI: 10.1021/acsnano.1c07363] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Micronanoswarms have attracted extensive attention worldwide due to their great promise in biomedical applications. The collective behaviors among thousands, or even millions, of tiny active agents indicate immense potential for benefiting the progress of clinical therapeutic and diagnostic methods. In recent years, with the development of smart materials, remote actuation modalities, and automatic control strategies, the motion dexterity, environmental adaptability, and functionality versatility of micronanoswarms are improved. Swarms can thus be designed as dexterous platforms inside living bodies to perform a multitude of tasks related to healthcare. Existing surveys summarize the design, functionalization, and biomedical applications of micronanorobots and the actuation and motion control strategies of micronanoswarms. This review presents the recent progress of micronanoswarms, aiming for biomedical applications. The recent advances on structural design of artificial, living, and hybrid micronanoswarms are summarized, and the biomedical applications that could be tackled using micronanoswarms are introduced, such as targeted drug delivery, hyperthermia, imaging and sensing, and thrombolysis. Moreover, potential challenges and promising trends of future developments are discussed. It is envisioned that the future success of these promising tools will have a significant impact on clinical treatment.
Collapse
Affiliation(s)
- Hui Chen
- School of Science and Engineering, The Chinese University of Hong Kong, Shenzhen 518172, China
- Shenzhen Institute of Artificial Intelligence and Robotics for Society (AIRS), Shenzhen 518129, China
| | - Huimin Zhang
- School of Science and Engineering, The Chinese University of Hong Kong, Shenzhen 518172, China
| | - Tiantian Xu
- Shenzhen Institute of Artificial Intelligence and Robotics for Society (AIRS), Shenzhen 518129, China
- Guangdong Provincial Key Laboratory of Robotics and Intelligent System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518126, China
| | - Jiangfan Yu
- School of Science and Engineering, The Chinese University of Hong Kong, Shenzhen 518172, China
- Shenzhen Institute of Artificial Intelligence and Robotics for Society (AIRS), Shenzhen 518129, China
| |
Collapse
|
4
|
Jiang X, Lillehoj PB. Microneedle-based skin patch for blood-free rapid diagnostic testing. MICROSYSTEMS & NANOENGINEERING 2020; 6:96. [PMID: 33194222 PMCID: PMC7605440 DOI: 10.1038/s41378-020-00206-1] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Revised: 07/24/2020] [Accepted: 08/15/2020] [Indexed: 06/02/2023]
Abstract
Rapid diagnostic tests are one of the most commonly used tests to detect and screen for infectious diseases in the developing world. While these tests are simple, inexpensive, and readily available, they rely on finger-prick blood sampling, which requires trained medical personnel, poses risks of infection, and can complicate cooperation in young children, asymptomatic individuals, and communities with blood taboos. Here, we report a novel microneedle-based skin patch for the rapid detection of protein biomarkers in dermal interstitial fluid. Sample collection is facilitated by a hydrophilic hollow microneedle array that autonomously extracts and transports interstitial fluid to an antibody-based lateral flow test strip via surface tension for colorimetric antigen detection. We employ a simple gold enhancement treatment to enhance the detection sensitivity of this colloidal gold-based lateral flow assay and elucidate the underlying mechanism of this enhancement mechanism through experimental investigation. For proof-of-concept, this device was used to detect Plasmodium falciparum histidine-rich protein 2, a biomarker for malaria infection, which could be detected at concentrations as low as 8 ng/mL. Each test can be completed in <20 min and requires no equipment. To the best of our knowledge, this work is the first demonstration of a microneedle-based lateral flow assay for rapid protein detection in dermal interstitial fluid. In addition to its simplicity, minimally invasive nature, and low cost, this diagnostic device can be readily adapted to detect other protein biomarkers in interstitial fluid, making it a promising tool for point-of-care testing.
Collapse
Affiliation(s)
- Xue Jiang
- Department of Mechanical Engineering, Rice University, Houston, TX 77005 USA
| | - Peter B. Lillehoj
- Department of Mechanical Engineering, Rice University, Houston, TX 77005 USA
- Department of Bioengineering, Rice University, Houston, TX 77030 USA
| |
Collapse
|
5
|
Zartner L, Muthwill MS, Dinu IA, Schoenenberger CA, Palivan CG. The rise of bio-inspired polymer compartments responding to pathology-related signals. J Mater Chem B 2020; 8:6252-6270. [PMID: 32452509 DOI: 10.1039/d0tb00475h] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Self-organized nano- and microscale polymer compartments such as polymersomes, giant unilamellar vesicles (GUVs), polyion complex vesicles (PICsomes) and layer-by-layer (LbL) capsules have increasing potential in many sensing applications. Besides modifying the physicochemical properties of the corresponding polymer building blocks, the versatility of these compartments can be markedly expanded by biomolecules that endow the nanomaterials with specific molecular and cellular functions. In this review, we focus on polymer-based compartments that preserve their structure, and highlight the key role they play in the field of medical diagnostics: first, the self-assembling abilities that result in preferred architectures are presented for a broad range of polymers. In the following, we describe different strategies for sensing disease-related signals (pH-change, reductive conditions, and presence of ions or biomolecules) by polymer compartments that exhibit stimuli-responsiveness. In particular, we distinguish between the stimulus-sensitivity contributed by the polymer itself or by additional compounds embedded in the compartments in different sensing systems. We then address necessary properties of sensing polymeric compartments, such as the enhancement of their stability and biocompatibility, or the targeting ability, that open up new perspectives for diagnostic applications.
Collapse
Affiliation(s)
- Luisa Zartner
- Chemistry Department, University of Basel, Mattenstr. 24a, BPR1096, Basel, Switzerland.
| | | | | | | | | |
Collapse
|
6
|
Fluorescent Biocompatible Platinum-Porphyrin-Doped Polymeric Hybrid Particles for Oxygen and Glucose Biosensing. Sci Rep 2019; 9:5029. [PMID: 30903010 PMCID: PMC6430792 DOI: 10.1038/s41598-019-41326-7] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Accepted: 02/28/2019] [Indexed: 12/23/2022] Open
Abstract
Near infrared (NIR) fluorophores like Pt-porphyrin along with analyte specific enzymes require co-encapsulation in biocompatible and biodegradable carriers in order to be transformed into implantable biosensors for efficient and continuous monitoring of analytes in patients. The main objective of this research is to develop natural, biodegradable, biocompatible and a novel co-encapsulated system of Pt-porphyrin encapsulated polymeric nanoparticle and nano-micro hybrid carriers. A sequential emulsification-solvent evaporation and an air driven atomization technique was used for developing above matrices and testing them for fluorescence based oxygen and glucose biosensing. The results indicate Pt-porphyrin can be efficiently encapsulated in Poly-lactic acid (PLA) nanoparticles and PLA-alginate nano-micro particles with sizes ~450 nm and 10 µm, respectively. Biosensing studies have showed a linear fluorescent response in oxygen concentrations ranging from of 0–6 mM (R2 = 0.992). The Oxygen sensitivity was transformed into a linear response of glucose catalytic reaction in the range of 0–10 mM (R2 = 0.968) with a response time of 4 minutes and a stability over 15 days. We believe that the investigated NIR fluorophores like Pt-Porphyrin based nano/nano-micro hybrid carrier systems are novel means of developing biocompatible biodegradable carriers for developing implantable glucose biosensors which can efficiently manage glucose levels in diabetes.
Collapse
|
7
|
Alberdi A, Aztiria A, Basarab A. Towards an automatic early stress recognition system for office environments based on multimodal measurements: A review. J Biomed Inform 2015; 59:49-75. [PMID: 26621099 DOI: 10.1016/j.jbi.2015.11.007] [Citation(s) in RCA: 136] [Impact Index Per Article: 15.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2015] [Revised: 11/16/2015] [Accepted: 11/19/2015] [Indexed: 01/07/2023]
Abstract
Stress is a major problem of our society, as it is the cause of many health problems and huge economic losses in companies. Continuous high mental workloads and non-stop technological development, which leads to constant change and need for adaptation, makes the problem increasingly serious for office workers. To prevent stress from becoming chronic and provoking irreversible damages, it is necessary to detect it in its early stages. Unfortunately, an automatic, continuous and unobtrusive early stress detection method does not exist yet. The multimodal nature of stress and the research conducted in this area suggest that the developed method will depend on several modalities. Thus, this work reviews and brings together the recent works carried out in the automatic stress detection looking over the measurements executed along the three main modalities, namely, psychological, physiological and behavioural modalities, along with contextual measurements, in order to give hints about the most appropriate techniques to be used and thereby, to facilitate the development of such a holistic system.
Collapse
Affiliation(s)
- Ane Alberdi
- Mondragon University, Electronics and Computing Department, Goiru Kalea, 2, Arrasate 20500, Spain.
| | - Asier Aztiria
- Mondragon University, Electronics and Computing Department, Goiru Kalea, 2, Arrasate 20500, Spain.
| | - Adrian Basarab
- Université de Toulouse, IRIT, CNRS UMR 5505, Université Paul Sabatier, Toulouse, France.
| |
Collapse
|
8
|
Andrus LP, Unruh R, Wisniewski NA, McShane MJ. Characterization of Lactate Sensors Based on Lactate Oxidase and Palladium Benzoporphyrin Immobilized in Hydrogels. BIOSENSORS 2015; 5:398-416. [PMID: 26198251 PMCID: PMC4600164 DOI: 10.3390/bios5030398] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2015] [Revised: 06/16/2015] [Accepted: 06/24/2015] [Indexed: 12/18/2022]
Abstract
An optical biosensor for lactate detection is described. By encapsulating enzyme-phosphor sensing molecules within permeable hydrogel materials, lactate-sensitive emission lifetimes were achieved. The relative amount of monomer was varied to compare three homo- and co-polymer materials: poly(2-hydroxyethyl methacrylate) (pHEMA) and two copolymers of pHEMA and poly(acrylamide) (pAam). Diffusion analysis demonstrated the ability to control lactate transport by varying the hydrogel composition, while having a minimal effect on oxygen diffusion. Sensors displayed the desired dose-variable response to lactate challenges, highlighting the tunable, diffusion-controlled nature of the sensing platform. Short-term repeated exposure tests revealed enhanced stability for sensors comprising hydrogels with acrylamide additives; after an initial "break-in" period, signal retention was 100% for 15 repeated cycles. Finally, because this study describes the modification of a previously developed glucose sensor for lactate analysis, it demonstrates the potential for mix-and-match enzyme-phosphor-hydrogel sensing for use in future multi-analyte sensors.
Collapse
Affiliation(s)
- Liam P Andrus
- Department of Biomedical Engineering, 5045 Emerging Technologies Building, 3120 TAMU, Texas A&M University, College Station, TX 77843, USA.
| | - Rachel Unruh
- Department of Biomedical Engineering, 5045 Emerging Technologies Building, 3120 TAMU, Texas A&M University, College Station, TX 77843, USA.
| | | | - Michael J McShane
- Department of Biomedical Engineering, 5045 Emerging Technologies Building, 3120 TAMU, Texas A&M University, College Station, TX 77843, USA.
- Department of Materials Science and Engineering, 3003 TAMU, Texas A&M University, College Station, TX 77843, USA.
| |
Collapse
|
9
|
del Mercato LL, Ferraro MM, Baldassarre F, Mancarella S, Greco V, Rinaldi R, Leporatti S. Biological applications of LbL multilayer capsules: from drug delivery to sensing. Adv Colloid Interface Sci 2014; 207:139-54. [PMID: 24625331 DOI: 10.1016/j.cis.2014.02.014] [Citation(s) in RCA: 107] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2013] [Revised: 02/15/2014] [Accepted: 02/15/2014] [Indexed: 11/24/2022]
Abstract
Polyelectrolyte multilayer (PEM) capsules engineered with active elements for targeting, labeling, sensing and delivery hold great promise for the controlled delivery of drugs and the development of new sensing platforms. PEM capsules composed of biodegradable polyelectrolytes are fabricated for intracellular delivery of encapsulated cargo (for example peptides, enzymes, DNA, and drugs) through gradual biodegradation of the shell components. PEM capsules with shells responsive to environmental or physical stimuli are exploited to control drug release. In the presence of appropriate triggers (e.g., pH variation or light irradiation) the pores of the multilayer shell are unlocked, leading to the controlled release of encapsulated cargos. By loading sensing elements in the capsules interior, PEM capsules sensitive to biological analytes, such as ions and metabolites, are assembled and used to detect analyte concentration changes in the surrounding environment. This Review aims to evaluate the current state of PEM capsules for drug delivery and sensing applications.
Collapse
|
10
|
Neubauer MP, Poehlmann M, Fery A. Microcapsule mechanics: from stability to function. Adv Colloid Interface Sci 2014; 207:65-80. [PMID: 24345731 DOI: 10.1016/j.cis.2013.11.016] [Citation(s) in RCA: 100] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2013] [Revised: 11/18/2013] [Accepted: 11/21/2013] [Indexed: 01/22/2023]
Abstract
Microcapsules are reviewed with special emphasis on the relevance of controlled mechanical properties for functional aspects. At first, assembly strategies are presented that allow control over the decisive geometrical parameters, diameter and wall thickness, which both influence the capsule's mechanical performance. As one of the most powerful approaches the layer-by-layer technique is identified. Subsequently, ensemble and, in particular, single-capsule deformation techniques are discussed. The latter generally provide more in-depth information and cover the complete range of applicable forces from smaller than pN to N. In a theory chapter, we illustrate the physics of capsule deformation. The main focus is on thin shell theory, which provides a useful approximation for many deformation scenarios. Finally, we give an overview of applications and future perspectives where the specific design of mechanical properties turns microcapsules into (multi-)functional devices, enriching especially life sciences and material sciences.
Collapse
|
11
|
Nanotechnology in glucose monitoring: Advances and challenges in the last 10 years. Biosens Bioelectron 2013; 47:12-25. [DOI: 10.1016/j.bios.2013.02.043] [Citation(s) in RCA: 195] [Impact Index Per Article: 17.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2012] [Revised: 02/20/2013] [Accepted: 02/26/2013] [Indexed: 12/31/2022]
|
12
|
Chan M, Estève D, Fourniols JY, Escriba C, Campo E. Smart wearable systems: current status and future challenges. Artif Intell Med 2012; 56:137-56. [PMID: 23122689 DOI: 10.1016/j.artmed.2012.09.003] [Citation(s) in RCA: 245] [Impact Index Per Article: 20.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2011] [Revised: 09/12/2012] [Accepted: 09/19/2012] [Indexed: 12/19/2022]
Abstract
OBJECTIVE Extensive efforts have been made in both academia and industry in the research and development of smart wearable systems (SWS) for health monitoring (HM). Primarily influenced by skyrocketing healthcare costs and supported by recent technological advances in micro- and nanotechnologies, miniaturisation of sensors, and smart fabrics, the continuous advances in SWS will progressively change the landscape of healthcare by allowing individual management and continuous monitoring of a patient's health status. Consisting of various components and devices, ranging from sensors and actuators to multimedia devices, these systems support complex healthcare applications and enable low-cost wearable, non-invasive alternatives for continuous 24-h monitoring of health, activity, mobility, and mental status, both indoors and outdoors. Our objective has been to examine the current research in wearable to serve as references for researchers and provide perspectives for future research. METHODS Herein, we review the current research and development of and the challenges facing SWS for HM, focusing on multi-parameter physiological sensor systems and activity and mobility measurement system designs that reliably measure mobility or vital signs and integrate real-time decision support processing for disease prevention, symptom detection, and diagnosis. For this literature review, we have chosen specific selection criteria to include papers in which wearable systems or devices are covered. RESULTS We describe the state of the art in SWS and provide a survey of recent implementations of wearable health-care systems. We describe current issues, challenges, and prospects of SWS. CONCLUSION We conclude by identifying the future challenges facing SWS for HM.
Collapse
Affiliation(s)
- Marie Chan
- Laboratory for Analysis and Architecture of Systems, National Center for Scientific Research, 7 Avenue du Colonel Roche, F-31400 Toulouse, France.
| | | | | | | | | |
Collapse
|
13
|
Mobed-Miremadi M, Asi B, Parasseril J, Wong E, Tat M, Shan Y. Comparative diffusivity measurements for alginate-based atomized and inkjet-bioprinted artificial cells using fluorescence microscopy. ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY 2012; 41:196-201. [PMID: 22992197 DOI: 10.3109/10731199.2012.716064] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Radial diffusivity profiles of atomized (MC, d = 1800 ± 200 µm) and inkjet-printed (MI, d = 40 ± 5 µm) alginate-based artificial cells have been generated using 2D Fluorescence Microscopy. The passive outward diffusion of FITC-Dextrans from MIs (0.5% LV alginate/15% CaCl2 coated with 0.5% Chitosan) and MCs (1.5% MV alginate/1.5% CaCl2) was measured and quantified using a Fickian model. As an expected outcome of miniaturization, the ratios of the outer layer diffusivities defined as D(MIout)/D(MCout) were 4.25 and 5.07 respectively for the 4 and 70 kDa markers, indicative of the enhanced diffusive potential of the miniaturized capsules.
Collapse
Affiliation(s)
- Maryam Mobed-Miremadi
- Department of Biomedical, Chemical and Materials Engineering, Davidson College of Engineering, San Jose State University, San Jose, CA 95192, USA.
| | | | | | | | | | | |
Collapse
|
14
|
Metaxa AF, Efthimiadou EK, Boukos N, Kordas G. Polysaccharides as a source of advanced materials: cellulose hollow microspheres for drug delivery in cancer therapy. J Colloid Interface Sci 2012; 384:198-206. [PMID: 22795041 DOI: 10.1016/j.jcis.2012.04.073] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2011] [Revised: 04/28/2012] [Accepted: 04/30/2012] [Indexed: 01/26/2023]
Abstract
Biocompatible hollow poly(methyl acrylic acid-co-N-isopropylacrylamide-co-ethyleneglycol dimethacrylate)@cellulose succinate (P(MAA-co-NIPAAM-co-EGDMA)@CS) microspheres have been synthesized by employing uniform silica-MPS microspheres as template. Silica spheres were synthesized via Stöber method involving tetraethyl orthosilicate. The surface of resulting silica Stöber microspheres was modified using 3-methacryloxypropyltrimethoxysilane (MPS), a polymerizable silane coupling agent. The above reagent introduces carbon-carbon double bonds on microspheres' surface. This strategy uses the copolymerization of the following monomers, methacrylic acid (MAA), N-isopropyl acrylamide (NIPAAM) and the ethyleneglycol dimethacrylate (EGDMA), which was used as cross-linker, aiming at fabricating the first shell. Distillation precipitation polymerization method was carried out with 2,2-azobis(2-methylpropionitrile) as initiator in acetonitrile aiming at coating the inorganic microspheres with organic shell of the above-mentioned copolymer. In continuation, cellulose succinate and cellulose powder was absorbed through electrostatic interactions onto microspheres' surface and the isolated product was cross-linked through esteric bonds formation. The cellulose succinate hollow microspheres were obtained after the silica core removal. The resulting spheres were characterized by Fourier transform infrared spectroscopy and observed by scanning and transmission electron microscopy. Dynamic light scattering was used to study the hydrodynamic diameter of the synthesized microspheres. The anticancer drug daunorubicin was loaded in the spheres, and its release behavior was evaluated at acidic and slightly basic pH conditions, aiming at evaluating its behavior at the healthy and pathogenic tissues.
Collapse
|
15
|
Reagentless fluorescent biosensors based on proteins for continuous monitoring systems. Anal Bioanal Chem 2012; 402:3039-54. [DOI: 10.1007/s00216-012-5715-2] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2011] [Accepted: 01/04/2012] [Indexed: 12/23/2022]
|
16
|
Li C, Wu Z, Hartings JA, Rajan N, Chahine N, Cheyuo C, Wang P, Wu PM, Golanov EV, Ahn CH, Narayan RK. Brain-friendly amperometric enzyme biosensor based on encapsulated oxygen generating biomaterial. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2012:6003-6006. [PMID: 23367297 DOI: 10.1109/embc.2012.6347362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
A novel first-generation Clark-type biosensor platform that can eliminate the oxygen dependence has been presented. Sufficient oxygen to drive the enzymatic reaction under hypoxic conditions was produced by encapsulated oxygen generating biomaterial, calcium peroxide. The catalase immobilized in chitosan matrix was coated on top of the groove to decompose residual hydrogen peroxide to oxygen. A glucose biosensor was developed on the proposed platform as proof of concept. Under hypoxic conditions, developed glucose biosensors maintained their sensitivity response around 84% of their response at oxygen tension of 151 mmHg. The sensitivity deviation was less than 5.3% with the oxygen tension traversed from 0 to 57 mmHg. Under oxygen tension of 8.3 mmHg, the sensitivity of 37.130 nA/mM and the linear coefficient of R(2)=0.9968 were obtained with the glucose concentration varying from 0.05 to 10mM. This new platform is particularly attractive for injured brain monitoring.
Collapse
Affiliation(s)
- Chunyan Li
- Cushing Neuromonitoroing Laboratory at Feinstein Institute for Medical Research, Manhasset, NY 11030, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Joshi A, Solanki S, Chaudhari R, Bahadur D, Aslam M, Srivastava R. Multifunctional alginate microspheres for biosensing, drug delivery and magnetic resonance imaging. Acta Biomater 2011; 7:3955-63. [PMID: 21784175 DOI: 10.1016/j.actbio.2011.06.053] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2011] [Revised: 06/17/2011] [Accepted: 06/30/2011] [Indexed: 11/25/2022]
Abstract
This research aims to develop and investigate a multifunctional implantable system capable of biosensing, drug delivery and magnetic resonance imaging (MRI) for continuous monitoring, controlled anti-inflammatory drug delivery and imaging, respectively. A glucose biosensor, diclofenac sodium (Diclo) and magnetic nanoparticles (MNP) were used as the biosensor component, anti-inflammatory agent and MRI contrast agent, respectively. MNP were synthesized by the co-precipitation technique and loaded with the sensor and drug components into alginate microspheres using a commercial droplet generator. The multifunctional system was then characterized using optical microscopy, scanning electron microscopy, transmission electron microscopy, X-ray diffraction, vibrating sample magnetometry (VSM) and MRI. The MNP were found to be in the size range of 5-15 nm. The final system, comprising the biosensor, drug and MNP loaded inside alginate microspheres, was found to be in the size range of 10-60 μm. Biosensing studies indicated an excellent glucose response curve, with a regression coefficient of 0.974 (0-10mM of glucose, response time: 4 min). In vitro Diclo release shows that MNP loading in alginate microspheres increases the burst release percentage by 11-12% in both 60 and 10 μm particles. However, the duration of release for 85% drug release decreases with MNP loading by 7 and 6 days for 39 the 60 and 10 μm particles, respectively. Super-paramagnetism was confirmed by VSM, with 2.09 and 1.368 emu g(-1), respectively, for the 60 and 10 μm particles, with no hysteresis. MRI showed significant contrast for both sizes. The particles showed an excellent biocompatibility (>80%) for all combinations of formulations. The system shows a great potential for biosensing with concurrent drug delivery and visualization for biomedical applications.
Collapse
|
18
|
Chaudhary A, Harma H, Hanninen P, McShane MJ, Srivastava R. Glucose response of near-infrared alginate-based microsphere sensors under dynamic reversible conditions. Diabetes Technol Ther 2011; 13:827-35. [PMID: 21568749 PMCID: PMC3133682 DOI: 10.1089/dia.2011.0057] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
BACKGROUND Minimally invasive optical glucose biosensors with increased functional longevity form one of the most promising techniques for continuous glucose monitoring, because of their long-term stability, reversibility, repeatability, specificity, and high sensitivity. They are based on the principle of competitive binding and fluorescence resonance energy transfer. Moving to the near-infrared region of the spectrum has the potential to improve signal throughput for implanted sensors, but requires a change in dye chemistry that could alter response sensitivity, range, and toxicity profiles. METHODS The near-infrared dissolved-core alginate microsphere sensors were fabricated by emulsion followed by surface coating by layer-by-layer self-assembly. The particles were characterized for sensor stability, sensor response, and reversibility in deionized water and simulated interstitial fluid. The sensor response to step changes in bulk glucose concentrations was also evaluated under dynamic conditions using a microflow cell unit. Finally, in vitro cytotoxicity assays were performed with L929 mouse fibroblast cell lines to demonstrate preliminary biocompatibility of the sensors. RESULTS The glucose sensitivity under controlled and dynamic conditions was observed to be 0.86%/mM glucose with an analytical response range of 0-30 mM glucose, covering both the physiological and pathophysiological range. The sensor demonstrated a repeatable, reversible, and reproducible response, with a maximum response time of 120 s. In vitro cytotoxicity assays revealed nearly 95% viability of cells, thereby suggesting that the alginate microsphere sensor system does not exhibit cytotoxicity. CONCLUSIONS The incorporation of near-infrared dyes shows promise in improving sensor response because of their high sensitivity and improved tissue penetration of infrared light. The sensitivity for the sensors was approximately 1.5 times greater than that observed for visible dye sensors, and the new dye chemistry did not significantly alter the biocompatibility of the materials. These findings provide additional support for the potential application of alginate microspheres and similar systems such as "smart-tattoo" glucose sensors.
Collapse
Affiliation(s)
- Ayesha Chaudhary
- Department of Biosciences and Bioengineering, IIT Bombay, Powai, Mumbai, India
| | - Harri Harma
- Laboratory of Biophysics and Medicity Research Laboratories, University of Turku, Turku, Finland
| | - Pekka Hanninen
- Laboratory of Biophysics and Medicity Research Laboratories, University of Turku, Turku, Finland
| | - Michael J. McShane
- Biomedical Engineering Department, Texas A & M University, College Station, Texas
| | - Rohit Srivastava
- Department of Biosciences and Bioengineering, IIT Bombay, Powai, Mumbai, India
| |
Collapse
|
19
|
Valdastri P, Susilo E, Forster T, Strohhofer C, Menciassi A, Dario P. Wireless Implantable Electronic Platform for Chronic Fluorescent-Based Biosensors. IEEE Trans Biomed Eng 2011; 58:1846-54. [DOI: 10.1109/tbme.2011.2123098] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
| | | | | | | | | | - Paolo Dario
- BioRobotics Institute, Scuola Superiore Sant’Anna, Italy
| |
Collapse
|
20
|
Tang D, Li Q, Tang J, Su B, Chen G. An enzyme-free quartz crystal microbalance biosensor for sensitive glucose detection in biological fluids based on glucose/dextran displacement approach. Anal Chim Acta 2011; 686:144-9. [DOI: 10.1016/j.aca.2010.11.054] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2010] [Revised: 11/28/2010] [Accepted: 11/30/2010] [Indexed: 11/29/2022]
|