1
|
Tu CF, Chen YC. Utilizing a Metal Inlet Coiled with Copper Wire as the Ion Source for Ambient Ionization Mass Spectrometry. Anal Chem 2024; 96:661-667. [PMID: 38170959 DOI: 10.1021/acs.analchem.3c02589] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2024]
Abstract
In ambient ionization mass spectrometry (MS), a customized metal inlet is typically adapted to the orifice of the mass spectrometer for ease of introduction of the sample. We herein explore that the metal inlet coiled with a copper wire (∼50 μm) can be directly used as an ion source to induce corona discharge-like processes for ionization of analytes in the gas phase. When the metal inlet is subjected to a high voltage in the mass spectrometer, the electric field provided by the mass spectrometer enables the generation of corona discharge to ionize volatile/semivolatile analytes derived from the sample in the condensed phase. The limit of detection for azulene derived from the aqueous sample was as low as ∼1 pM. Moreover, we also demonstrated the feasibility of coupling ultraviolet-visible absorption spectroscopy with MS by using the metal inlet coiled with a thin copper wire as the interface. Integration of these two techniques enables the simultaneous acquisition of spectra from both instruments for quantitative and qualitative analysis of the sample. Furthermore, we showed that polar and nonpolar analytes in a mixture can be acquired in the same mass spectrum by simply depositing a sample droplet (∼20 μL) on a dielectric substrate near the copper wire-coiled metal inlet of the mass spectrometer. The ionization processes involved both electrospray ionization and corona discharge. To demonstrate the applicability of our method for detecting nonpolar and polar analytes in complex samples, we spiked a nonpolar analyte, benzo[a]pyrene, to a spice sample and successfully detected analytes with different polarities using our approach.
Collapse
Affiliation(s)
- Chi-Feng Tu
- Department of Applied Chemistry, National Yang Ming Chiao Tung University, Hsinchu 300, Taiwan
| | - Yu-Chie Chen
- Department of Applied Chemistry, National Yang Ming Chiao Tung University, Hsinchu 300, Taiwan
- International College of Semiconductor Technology, National Yang Ming Chiao Tung University, Hsinchu 300, Taiwan
| |
Collapse
|
2
|
Knodel A, Marggraf U, Hoffmann-Posorske E, Burhenn S, Brandt S, Ahlmann N, Foest D, Lorenz K, Franzke J. Pulsed Blue Laser Diode Thermal Desorption Microplasma Imaging Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:45-53. [PMID: 34856796 DOI: 10.1021/jasms.1c00221] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
An ambient air laser desorption, plasma ionization imaging method is developed and presented using a microsecond pulsed laser diode for desorption and a flexible microtube plasma for ionization of the neutral desorbate. Inherent parameters such as the laser repetition rate and pulse width are optimized to the imaging application. For the desorption substrate, copper spots on a copper-glass sandwich structure are used. This novel design enables imaging without ablating the metal into the mass spectrometer. On this substrate, fixed calibration markers are used to decrease the positioning error in the imaging process, featuring a 3D offset correction within the experiment. The image is both screened spot-by-spot and per line scanning at a constant speed, which allows direct comparison. In spot-by-spot scanning, a novel algorithm is presented to unfold and to reconstruct the imaging data. This approach significantly decreases the time required for the imaging process, which allows imaging even at decreased sampling rates and thus higher mass resolution. After the experiment, the raw data is automatically converted and interpreted by a second algorithm, which allows direct visualization of the image from the data, even on low-intensity signals. Mouse liver microtome cuts have been screened for dehydrated cholesterol, proving good agreement of the unfolded data with the morphology of the tissue. The method optically resolves 30 μm, with 30 μm diameter copper spots and a 10 μm gap. No conventional chemical matrices or vacuum conditions are required.
Collapse
Affiliation(s)
- Alexander Knodel
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Ulrich Marggraf
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Edeltraut Hoffmann-Posorske
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Sebastian Burhenn
- Experimental Physics II, Faculty of Physics and Astronomy, Ruhr-University Bochum, 44801 Bochum, Germany
| | - Sebastian Brandt
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Norman Ahlmann
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Daniel Foest
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Kristina Lorenz
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
- Institute of Pharmacology and Toxicology, University of Würzburg, 97078 Würzburg, Germany
| | - Joachim Franzke
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| |
Collapse
|
3
|
Chen L, Ghiasvand A, Rodriguez ES, Innis PC, Paull B. Applications of nanomaterials in ambient ionization mass spectrometry. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116202] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
4
|
Shiea J, Bhat SM, Su H, Kumar V, Lee CW, Wang CH. Rapid quantification of acetaminophen in plasma using solid-phase microextraction coupled with thermal desorption electrospray ionization mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34 Suppl 1:e8564. [PMID: 31490602 DOI: 10.1002/rcm.8564] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2019] [Revised: 08/11/2019] [Accepted: 08/21/2019] [Indexed: 06/10/2023]
Abstract
RATIONALE Solid-phase microextraction coupled with thermal desorption electrospray ionization tandem mass spectrometry (SPME-TD-ESI-MS/MS) is proposed as a novel method for the rapid quantification of acetaminophen in plasma samples from a pharmacokinetics (PK) study. METHODS Traces of acetaminophen were concentrated on commercial fused-silica fibers coated with a polar polyacrylate (PA) polymer using direct immersion SPME. No agitation, heating, addition of salt, or adjustment of the pH of the sample solution was applied during the extraction. Any acetaminophen absorbed on the SPME fibers was subsequently desorbed and detected by TD-ESI-MS/MS. RESULTS Parameters of the absorption, sensitivity, reproducibility, and linearity for the SPME-TD-ESI-MS/MS method were evaluated. The time required to complete a TD-ESI-MS/MS analysis was less than 30 seconds. Matrix-matching calibration was performed to calculate the concentration of acetaminophen in the sample. A linear calibration curve with a concentration range of 100-10,000 ng/mL was constructed to calculate the quantity of acetaminophen. The SPME-TD-ESI-MS quantification results for acetaminophen in plasma were in good agreement with those obtained by the conventional LC/MS/MS method. CONCLUSIONS With the proposed method, a 10-min SPME time was enough to achieve the lower limit of quantitation (i.e. 100 ng/mL) and for a complete PK profiling of acetaminophen. A shorter extraction time could be achieved by applying agitation, heating, adding salt, or adjusting the pH of the sample solution to enhance analyte absorption efficiency. The time required to detect acetaminophen on the SPME fiber was less than 30 s, allowing the rapid quantification of acetaminophen in plasma with good accuracy.
Collapse
Affiliation(s)
- Jentaie Shiea
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
- Department of Medical and Applied Chemistry, Kaohsiung Medical University, Kaohsiung, Taiwan
| | | | - Hung Su
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - Vinoth Kumar
- Department of Medical and Applied Chemistry, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Chi-Wei Lee
- Institute of Medical Science and Technology, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - Chin-Hsiung Wang
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
| |
Collapse
|
5
|
GUO XY, HUANG XM, ZHAI JF, BAI H, LI XX, MA XX, MA Q. Research Advances in Ambient Ionization and Miniature Mass Spectrometry. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2019. [DOI: 10.1016/s1872-2040(19)61145-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
6
|
Kim DB, Yoon S. Study of Photocatalytic Nano-Particle Effects on the Low Temperature Plasma Ionization Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:2333-2340. [PMID: 30238193 DOI: 10.1007/s13361-018-2059-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Revised: 07/31/2018] [Accepted: 08/14/2018] [Indexed: 06/08/2023]
Abstract
Although the low temperature plasma mass spectrometry (LTP-MS) is widely used as an analysis tool for many biochemical samples, its application window is somehow limited to the analytes of low molecular mass and high volatility. For this reason, there have been attempts to enhance the ionization/desorption efficiencies with extra heating, for instance. In this study, another enhancement method was suggested using the photocatalytic nano-particles (NPs). In order to assess the NP effects on the LTP-MS, two fatty acid ethyl ester samples of ethyl myristate and ethyl palmitate were used, and the NP of titanium dioxide (TiO2) was mainly employed. The results showed that the signal intensities of the LTP-MS were largely increased with the TiO2 addition for both samples. In addition, the cholesterol sample was analyzed using the TiO2 assisted LTP-MS, also resulting in the enhancement of the signal intensity. The overall results inferred that the photocatalytic NP confirmed its role as an effective assist tool for the LTP-MS, especially suitable because of the facile method and the heat-free nature. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Dan Bee Kim
- Center for Electriomagnetic Standards, Korea Research Institute of Standards and Science, Daejeon, 34113, Republic of Korea
| | - Sohee Yoon
- Center for Nano-Bio Measurement, Korea Research Institute of Standards and Science, Daejeon, 34113, Republic of Korea.
| |
Collapse
|
7
|
Teunissen SF, Eberlin MN. Transferring Ions from Solution to the Gas Phase: The Two Basic Principles. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:2255-2261. [PMID: 28856608 DOI: 10.1007/s13361-017-1779-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2017] [Revised: 08/04/2017] [Accepted: 08/04/2017] [Indexed: 06/07/2023]
Abstract
The efficient formation of gaseous ions is the crucial step in all successful mass spectrometric experiments. The invention of electrospray ionization (ESI) has strongly facilitated this step by transferring preformed ions directly from solution to the gas phase - thereby circumventing the need to first convert analytes to the gas phase and then ionize them - and therefore ESI has become an extremely useful and widely applied MS technique. The invention of sonic spray ionization (SSI) has also allowed for the transfer of ions from solution into the gas phase, but without the assistance of a voltage or heating. Numerous ionization techniques, using similar principles to those applied in either ESI or SSI, have subsequently been developed. Although experimental conditions used in such techniques vary markedly, herein we argue that they are all based on either one of two basic principles by which ions can be transferred from solution to the gas phase, that is: via (1) neutralizing the counter ion, or (2) separating the ions. We have selected 35 such techniques and categorized them accordingly. This article thereby aims to establish the basic principles by which gaseous ions can be obtained from solvated ions. We further propose that any new ionization technique used to transfer solvated ions to the gas phase will similarly fall into one of these two mechanistic categories. Graphical abstract.
Collapse
Affiliation(s)
- Sebastiaan F Teunissen
- ThoMSon Mass Spectrometry Laboratory, University of Campinas-UNICAMP, Campinas, 13083-970, Brazil.
| | - Marcos N Eberlin
- ThoMSon Mass Spectrometry Laboratory, University of Campinas-UNICAMP, Campinas, 13083-970, Brazil
| |
Collapse
|
8
|
Cho YT, Su H, Lin SJ, Wu BH, Lai CY, Huang IC. Using thermal desorption electrospray ionization mass spectrometry to rapidly determine antimicrobial preservatives in cosmetics. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2016; 30:2315-2322. [PMID: 27488136 DOI: 10.1002/rcm.7706] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2016] [Revised: 07/23/2016] [Accepted: 07/30/2016] [Indexed: 06/06/2023]
Abstract
RATIONALE Characterization and quantification of permitted preservatives are important inspections to prevent the overuse of preservatives in authentic formulations. However, the complexity of sample matrices makes preservative determination in cosmetics a tedious process. A rapid analytical strategy to identify preservatives would insure large numbers of products are in compliance with government regulations. METHODS Thermal desorption electrospray ionization mass spectrometry (TD-ESI-MS) was used to directly detect preservative compounds in authentic formulations without sample pretreatment. The technique employs a metal probe, which was configured for sampling cosmetics in their original states and was inserted in a closed preheated oven to thermally desorb analytes. The desorbed analytes were then carried by a nitrogen gas stream into an ESI plume, where the formed ions were subsequently detected by the mass analyzer. RESULTS The TD-ESI mass and tandem mass spectra of different classes of preservative standards were rapidly obtained, and the limits of detection were far below the legal limit of their respective concentrations. The preservatives were also directly detected in different types of authentic formulations in the absence of sample preparation, and within a few seconds per sample. Calibration curves for preservatives in four common formulations yielded good linearity in the regulation-allowed range. CONCLUSIONS Due to its sensitivity, short analysis time, repeatability, and quantitative ability, TD-ESI-MS may serve as a suitable tool for large-scale screening of cosmetic preservatives to assure product safety. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Yi-Tzu Cho
- Department of Cosmetic Applications and Management, Yuh-Ing Junior College of Health Care & Management, Kaohsiung, Taiwan.
| | - Hung Su
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - Shiang-Jiun Lin
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - Ban-Hsin Wu
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - Ching-Yu Lai
- Department of Cosmetic Applications and Management, Yuh-Ing Junior College of Health Care & Management, Kaohsiung, Taiwan
| | - I-Ching Huang
- Department of Cosmetic Applications and Management, Yuh-Ing Junior College of Health Care & Management, Kaohsiung, Taiwan
| |
Collapse
|
9
|
Yang Y, Han F, Ouyang J, Zhao Y, Han J, Na N. In-situ nanoelectrospray for high-throughput screening of enzymes and real-time monitoring of reactions. Anal Chim Acta 2016; 902:135-141. [DOI: 10.1016/j.aca.2015.10.032] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2015] [Accepted: 10/26/2015] [Indexed: 12/24/2022]
|
10
|
Chang CH, Chen TY, Chen YC. Microfluidic Chip Coupled with Thermal Desorption Atmospheric Pressure Ionization Mass Spectrometry. Mass Spectrom (Tokyo) 2014; 3:S0026. [PMID: 26839753 DOI: 10.5702/massspectrometry.s0026] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2013] [Accepted: 12/10/2013] [Indexed: 11/23/2022] Open
Abstract
Microfluidic chips have been used as platforms for a diversity of research purposes such as for separation and micro-reaction. One of the suitable detectors for microfluidic chip is mass spectrometry. Because microfluidic chips are generally operated in an open air condition, mass spectrometry coupled with atmospheric pressure ion sources can suit the requirement with minimum compromise. In this study, we develop a new interface to couple a microfluidic chip with mass spectrometry. A capillary tip coated with a layer of graphite, capable of absorbing energy of near-infrared (NIR) light is used to interface microfluidic chip with mass spectrometry. An NIR laser diode (λ=808 nm) is used to irradiate the capillary tip for assisting the generation of spray from the eluent of the microfluidic chip. An electrospray is provided to fuse with the spray generated from the microfluidic chip for post-ionization. Transesterification is used as the example to demonstrate the feasibility of using this interface to couple microfluidic chip with mass spectrometry.
Collapse
Affiliation(s)
| | - Tsung-Yi Chen
- Department of Applied Chemistry, National Chiao Tung University
| | - Yu-Chie Chen
- Department of Applied Chemistry, National Chiao Tung University
| |
Collapse
|
11
|
Kuo TR, Wang DY, Chiu YC, Yeh YC, Chen WT, Chen CH, Chen CW, Chang HC, Hu CC, Chen CC. Layer-by-layer thin film of reduced graphene oxide and gold nanoparticles as an effective sample plate in laser-induced desorption/ionization mass spectrometry. Anal Chim Acta 2013; 809:97-103. [PMID: 24418138 DOI: 10.1016/j.aca.2013.11.050] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2013] [Revised: 11/15/2013] [Accepted: 11/24/2013] [Indexed: 11/30/2022]
Abstract
This work demonstrated a simple platform for rapid and effective surface-assisted laser desorption/ionization time-of-flight mass spectrometry (SALDI-TOF MS) measurements based on the layer structure of reduced graphene oxide (rGO) and gold nanoparticles. A multi-layer thin film was fabricated by alternate layer-by-layer depositions of rGO and gold nanoparticles (LBL rGO/AuNP). The flat and clean two-dimensional film was served as the sample plate and also functioned as the matrix in SALDI-TOF MS. By simply one-step deposition of analytes onto the LBL rGO/AuNP sample plate, the MS measurements of various homogeneous samples were ready to execute. The optimization of MS signal was reached by the variation of the layer numbers of rGO and gold nanoparticles. Also, the small molecules including amino acids, carbohydrates and peptides were successfully analyzed in SALDI-TOF MS using the LBL rGO/AuNP sample plate. The results showed that the signal intensity, S N(-1) ratio and reproducibility of SALDI-TOF spectra have been significantly improved in comparison to the uses of gold nanoparticles or α-cyano-4-hydroxy-cinnamic acid (CHCA) as the assisted matrixes. Taking the advantages of the unique properties of rGO and gold nanoparticles, the ready-to-use MS sample plate, which could absorb and dissipate laser energy to analytes quite efficiently and homogeneously, has shown great commercial potentials for MS applications.
Collapse
Affiliation(s)
- Tsung-Rong Kuo
- Department of Chemistry, National Taiwan Normal University, Taipei 11677, Taiwan; Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei 10617, Taiwan
| | - Di-Yan Wang
- Department of Chemistry, National Taiwan Normal University, Taipei 11677, Taiwan; Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei 10617, Taiwan; Department of Materials Science and Engineering, National Taiwan University, Taipei 10617, Taiwan
| | - Yu-Chen Chiu
- Department of Chemistry, National Taiwan Normal University, Taipei 11677, Taiwan
| | - Yun-Chieh Yeh
- Department of Materials Science and Engineering, National Taiwan University, Taipei 10617, Taiwan
| | - Wei-Ting Chen
- Department of Chemistry, National Taiwan Normal University, Taipei 11677, Taiwan
| | - Ching-Hui Chen
- Department of Applied Science, National Taitung University, Taitung 95002, Taiwan
| | - Chun-Wei Chen
- Department of Materials Science and Engineering, National Taiwan University, Taipei 10617, Taiwan
| | - Huan-Cheng Chang
- Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei 10617, Taiwan
| | - Cho-Chun Hu
- Department of Applied Science, National Taitung University, Taitung 95002, Taiwan.
| | - Chia-Chun Chen
- Department of Chemistry, National Taiwan Normal University, Taipei 11677, Taiwan; Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei 10617, Taiwan.
| |
Collapse
|
12
|
Huang MZ, Zhou CC, Liu DL, Jhang SS, Cheng SC, Shiea J. Rapid Characterization of Chemical Compounds in Liquid and Solid States Using Thermal Desorption Electrospray Ionization Mass Spectrometry. Anal Chem 2013; 85:8956-63. [DOI: 10.1021/ac401364k] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Affiliation(s)
- Min-Zong Huang
- Department
of Chemistry, National Sun Yat-Sen University, Kaohsiung, 80424 Taiwan
| | - Chi-Chang Zhou
- Department
of Chemistry, National Sun Yat-Sen University, Kaohsiung, 80424 Taiwan
| | - De-Lin Liu
- Department
of Chemistry, National Sun Yat-Sen University, Kaohsiung, 80424 Taiwan
| | - Siou-Sian Jhang
- Department
of Chemistry, National Sun Yat-Sen University, Kaohsiung, 80424 Taiwan
| | - Sy-Chyi Cheng
- Department
of Chemistry, National Sun Yat-Sen University, Kaohsiung, 80424 Taiwan
| | - Jentaie Shiea
- Department
of Chemistry, National Sun Yat-Sen University, Kaohsiung, 80424 Taiwan
- Department
of Medicinal and Applied Chemistry, Kaohsiung Medical University, Kaohsiung, 80708 Taiwan
| |
Collapse
|
13
|
Huang MZ, Cheng SC, Cho YT, Shiea J. Ambient ionization mass spectrometry: A tutorial. Anal Chim Acta 2011; 702:1-15. [PMID: 21819855 DOI: 10.1016/j.aca.2011.06.017] [Citation(s) in RCA: 220] [Impact Index Per Article: 16.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2011] [Revised: 06/07/2011] [Accepted: 06/07/2011] [Indexed: 10/18/2022]
|