1
|
Kamola P, Przygodzki T. Qualitative classification of thrombus images as a way to improve quantitative analysis of thrombus formation in flow chamber assays. PLoS One 2024; 19:e0299202. [PMID: 38466712 PMCID: PMC10927075 DOI: 10.1371/journal.pone.0299202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Accepted: 02/07/2024] [Indexed: 03/13/2024] Open
Abstract
BACKGROUND Thrombus formation in vitro under flow conditions is one of the most widely used methods to study haemostasis and to evaluate the activity of potential antithrombotic compounds. Assessment of the results of these experiments is often based on a quantification of microscopic images of thrombi. In a majority of reported analysis all thrombi visualised in an image are quantified as one homogenous class. In some protocols, qualitative assessment of thrombi morphology based on a visual comparison of evaluated images with representative images of predefined classes of thrombi are performed by experienced analysts. In presented paper we show how the quantitative analysis can be improved by classification of thrombi on the basis of defined morphological features prior to quantification and we suggest that machine learning-based approach can improve this way of analysis. METHODS We tested the applicability of machine learning-based segmentation and classification of thrombi images to improve the outcome of quantification of the results of flow chamber assays. For this, we used the public domain machine learning software Ilastik for bioimage analysis developed at the European Molecular Biology Laboratory. A model was trained to distinguish two classes of thrombi based on certain morphological features which apparently correspond to the stage of thrombus development. Thrombi formed in the presence of a model antiplatelet compound-abciximab or in control conditions were quantified with the use of this model and the results were compared to quantification where all thrombi were quantified as a homogenous class. RESULTS Machine learning-based analysis was capable of effective distinguishing of two classes of morphologically distinct platelet aggregates. The use of the model which segmented and quantified only the objects recognized as compacted structures provided results which better mirrored the actual effect of an antiplatelet treatment than quantification based on all structures. CONCLUSIONS Classification of thrombi enabled by machine learning increases the relevance of quantitative information and allows better evaluation of the results of in vitro thrombosis assays.
Collapse
Affiliation(s)
- Piotr Kamola
- Department of Haemostatic Disorders, Medical University of Lodz, Lodz, Poland
| | - Tomasz Przygodzki
- Department of Haemostatic Disorders, Medical University of Lodz, Lodz, Poland
| |
Collapse
|
2
|
Chan J, Michaelsen K, Estergreen JK, Sabath DE, Gollakota S. Micro-mechanical blood clot testing using smartphones. Nat Commun 2022; 13:831. [PMID: 35149711 PMCID: PMC8837659 DOI: 10.1038/s41467-022-28499-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Accepted: 01/26/2022] [Indexed: 11/09/2022] Open
Abstract
Frequent prothrombin time (PT) and international normalized ratio (INR) testing is critical for millions of people on lifelong anticoagulation with warfarin. Currently, testing is performed in hospital laboratories or with expensive point-of-care devices limiting the ability to test frequently and affordably. We report a proof-of-concept PT/INR testing system that uses the vibration motor and camera on smartphones to track micro-mechanical movements of a copper particle. The smartphone system computed the PT/INR with inter-class correlation coefficients of 0.963 and 0.966, compared to a clinical-grade coagulation analyzer for 140 plasma samples and demonstrated similar results for 80 whole blood samples using a single drop of blood (10 μl). When tested with 79 blood samples with coagulopathic conditions, the smartphone system demonstrated a correlation of 0.974 for both PT/INR. Given the ubiquity of smartphones in the global setting, this proof-of-concept technology may provide affordable and effective PT and INR testing in low-resource environments. Therapy with anticoagulants requires frequent monitoring. Here the authors describe a proof-of-concept study of a simple and affordable blood clot test that uses a smartphone’s vibration motor and camera to track micro-movements in a single drop of blood.
Collapse
Affiliation(s)
- Justin Chan
- Paul G. Allen School of Computer Science and Engineering, University of Washington, Seattle, WA, USA.
| | - Kelly Michaelsen
- Department of Anesthesiology & Pain Medicine, University of Washington, Seattle, WA, USA.
| | - Joanne K Estergreen
- Department of Laboratory Medicine & Pathology, University of Washington, Seattle, WA, USA
| | - Daniel E Sabath
- Department of Laboratory Medicine & Pathology, University of Washington, Seattle, WA, USA
| | - Shyamnath Gollakota
- Paul G. Allen School of Computer Science and Engineering, University of Washington, Seattle, WA, USA.
| |
Collapse
|
3
|
Oseev A, Lecompte T, Remy-Martin F, Mourey G, Chollet F, de Boiseaumarie BLR, Rouleau A, Bourgeois O, de Maistre E, Elie-Caille C, Manceau JF, Boireau W, Leblois T. Assessment of Shear-Dependent Kinetics of Primary Haemostasis With a Microfluidic Acoustic Biosensor. IEEE Trans Biomed Eng 2020; 68:2329-2338. [PMID: 33055022 DOI: 10.1109/tbme.2020.3031542] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Primary haemostasis is a complex dynamic process, which involves in-flow interactions between platelets and sub-endothelial matrix at the area of the damaged vessel wall. It results in a first haemostatic plug, which stops bleeding, before coagulation ensues and consolidates it. The diagnosis of primary haemostasis defect would benefit from evaluation of the whole sequence of mechanisms involved in platelet plug formation in flow. This work proposes a new approach that is based on characterization of the shear-dependent kinetics that enables the evaluation of the early stages of primary haemostasis. We used a label-free method with a quartz crystal microbalance (QCM) biosensor to measure the platelet deposits over time onto covalently immobilized type I fibrillar collagen. We defined three metrics: total frequency shift, lag time, and growth rate. The measurement was completed at four predefined shear rates prevailing in small vessels (500, 770, 1000 and 1500 s-1) during five minutes of perfusion with anticoagulated normal whole blood. The rate of the frequency shift over the first five minutes was strongly influenced by shear rate conditions, presenting a maximum around 770 s-1, and varying by a factor larger than three in the studied shear rate range. To validate the biosensor signal, the total frequency shift was compared to results obtained by atomic force microscopy (AFM) on final platelet deposits. The results show that shear-dependent kinetic assays are promising as an advanced method for screening of primary haemostasis.
Collapse
|
4
|
Mohammadi Aria M, Erten A, Yalcin O. Technology Advancements in Blood Coagulation Measurements for Point-of-Care Diagnostic Testing. Front Bioeng Biotechnol 2019; 7:395. [PMID: 31921804 PMCID: PMC6917661 DOI: 10.3389/fbioe.2019.00395] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Accepted: 11/21/2019] [Indexed: 12/24/2022] Open
Abstract
In recent years, blood coagulation monitoring has become crucial to diagnosing causes of hemorrhages, developing anticoagulant drugs, assessing bleeding risk in extensive surgery procedures and dialysis, and investigating the efficacy of hemostatic therapies. In this regard, advanced technologies such as microfluidics, fluorescent microscopy, electrochemical sensing, photoacoustic detection, and micro/nano electromechanical systems (MEMS/NEMS) have been employed to develop highly accurate, robust, and cost-effective point of care (POC) devices. These devices measure electrochemical, optical, and mechanical parameters of clotting blood. Which can be correlated to light transmission/scattering, electrical impedance, and viscoelastic properties. In this regard, this paper discusses the working principles of blood coagulation monitoring, physical and sensing parameters in different technologies. In addition, we discussed the recent progress in developing nanomaterials for blood coagulation detection and treatments which opens up new area of controlling and monitoring of coagulation at the same time in the future. Moreover, commercial products, future trends/challenges in blood coagulation monitoring including novel anticoagulant therapies, multiplexed sensing platforms, and the application of artificial intelligence in diagnosis and monitoring have been included.
Collapse
Affiliation(s)
| | - Ahmet Erten
- Department of Electronics and Communication Engineering, Istanbul Technical University, Istanbul, Turkey
| | - Ozlem Yalcin
- Graduate School of Biomedical Sciences and Engineering, Koc University, Sariyer, Turkey
- Department of Physiology, Koc University School of Medicine, Koc University, Sariyer, Turkey
| |
Collapse
|
5
|
Weber M, Steinle H, Golombek S, Hann L, Schlensak C, Wendel HP, Avci-Adali M. Blood-Contacting Biomaterials: In Vitro Evaluation of the Hemocompatibility. Front Bioeng Biotechnol 2018; 6:99. [PMID: 30062094 PMCID: PMC6054932 DOI: 10.3389/fbioe.2018.00099] [Citation(s) in RCA: 305] [Impact Index Per Article: 50.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2018] [Accepted: 06/26/2018] [Indexed: 12/15/2022] Open
Abstract
Hemocompatibility of blood-contacting biomaterials is one of the most important criteria for their successful in vivo applicability. Thus, extensive in vitro analyses according to ISO 10993-4 are required prior to clinical applications. In this review, we summarize essential aspects regarding the evaluation of the hemocompatibility of biomaterials and the required in vitro analyses for determining the blood compatibility. Static, agitated, or shear flow models are used to perform hemocompatibility studies. Before and after the incubation of the test material with fresh human blood, hemolysis, cell counts, and the activation of platelets, leukocytes, coagulation and complement system are analyzed. Furthermore, the surface of biomaterials are evaluated concerning attachment of blood cells, adsorption of proteins, and generation of thrombus and fibrin networks.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Meltem Avci-Adali
- Department of Thoracic and Cardiovascular Surgery, University Hospital Tübingen, Tübingen, Germany
| |
Collapse
|
6
|
Hussain M, Rupp F, Wendel HP, Gehring FK. Bioapplications of acoustic crystals, a review. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.02.009] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
7
|
QCM-D surpassing clinical standard for the dose administration of new oral anticoagulant in the patient of coagulation disorders. Biosens Bioelectron 2017; 104:15-20. [PMID: 29294406 DOI: 10.1016/j.bios.2017.12.043] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2017] [Revised: 12/20/2017] [Accepted: 12/26/2017] [Indexed: 11/20/2022]
Abstract
The study focuses the dose administration of dabigatran to avoid the deaths due to hemorrhagic complications and thromboembolic stroke in clinics worldwide. To target the issue, a novel emerging acoustic technology, namely ''Quartz Crystal Microbalance with Dissipation'' (QCM-D) has been applied, while the acoustic assays namely ''activated Partial Thromboplastin Time'' (aPTT) and ''Prothrombinase complex-induced Clotting Test'' (PiCT) have been compared with the standard methods in parallel. Both techniques have been applied to 300 samples, including 220 plasma samples of patients suffering coagulation disorders and 80 plasma samples of non-patients. In comparison, the coagulation times of the acoustic aPTT and PiCT yielded an excellent correlation with the standard methods with in analytical standard deviation limits. Finally, the acoustic aPTT assay is the ''gold standard'' for a dose administration of the new oral anticoagulant, where the Δf/ΔΓ ratio of the acoustic assay demonstrates that dabigatran with FEIBA 50 combination could be a safe remedy to avoid the deaths in clinics.
Collapse
|
8
|
Wu H, Zhao G, Zu H, Wang JHC, Wang QM. Real-Time Monitoring of Platelet Activation Using Quartz Thickness-Shear Mode Resonator Sensors. Biophys J 2017; 110:669-679. [PMID: 26840731 DOI: 10.1016/j.bpj.2015.11.3511] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2015] [Revised: 11/11/2015] [Accepted: 11/19/2015] [Indexed: 12/16/2022] Open
Abstract
In this study, quartz thickness-shear mode (TSM) resonator sensors were adopted to monitor the process of platelet activation. Resting platelets adhering to fibrinogen-coated electrodes were activated by different concentrations of thrombin (1, 10, and 100 U/mL), and the corresponding electrical admittance spectra of TSM resonators during this process were recorded. Based on a bilayer-loading transmission line model of TSM resonators, the complex shear modulus (G' + jG″) and the average thickness (hPL) of the platelet monolayer at a series of time points were obtained. Decrease in thrombin concentration from 100 to 1 U/mL shifted all peaks and plateaus in G', G″, and hPL to higher time points, which could be attributed to the partial activation of platelets by low concentrations of thrombin. The peak value of hPL was acquired when platelets presented their typical spherical shape as the first transformation in activation process. The G' peak appeared 10 ∼ 20 min after hPL peak, when some filopods were observed along the periphery of platelets but without obvious cell spreading. As platelet spreading began and continued, G', G″, and hPL decreased, leading to a steady rise of resonance frequency shift of TSM resonator sensors. The results show high reliability and stability of TSM resonator sensors in monitoring the process of platelet activation, revealing an effective method to measure platelet activities in real-time under multiple experimental conditions. The G', G″, and hPL values could provide useful quantitative measures on platelet structure variations in activation process, indicating potential of TSM resonators in characterization of cells during their transformation.
Collapse
Affiliation(s)
- Huiyan Wu
- Department of Mechanical Engineering & Materials Science, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Guangyi Zhao
- MechanoBiology Laboratory, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - Hongfei Zu
- Department of Mechanical Engineering & Materials Science, University of Pittsburgh, Pittsburgh, Pennsylvania
| | - James H-C Wang
- MechanoBiology Laboratory, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania.
| | - Qing-Ming Wang
- Department of Mechanical Engineering & Materials Science, University of Pittsburgh, Pittsburgh, Pennsylvania.
| |
Collapse
|
9
|
Kömpf D, Held J, Müller SF, Drechsel HR, Tschan SC, Northoff H, Mordmüller B, Gehring FK. Real-time measurement of Plasmodium falciparum-infected erythrocyte cytoadhesion with a quartz crystal microbalance. Malar J 2016; 15:317. [PMID: 27296675 PMCID: PMC4906606 DOI: 10.1186/s12936-016-1374-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2016] [Accepted: 06/04/2016] [Indexed: 11/13/2022] Open
Abstract
Background An important virulence mechanism of the malaria parasite Plasmodium falciparum is cytoadhesion, the binding of infected erythrocytes to endothelial cells in the second half of asexual blood stage development. Conventional methods to investigate adhesion of infected erythrocytes are mostly performed under static conditions, many are based on manual or semi-automated read-outs and are, therefore, difficult to standardize. Quartz crystal microbalances (QCM) are sensitive to nanogram-scale changes in mass and biomechanical properties and are increasingly used in biomedical research. Here, the ability of QCM is explored to measure binding of P. falciparum-infected erythrocytes to two receptors: CD36 and chondroitin sulfate A (CSA) under flow conditions. Methods Binding of late stage P. falciparum parasites is measured in comparison to uninfected erythrocytes to CD36- and CSA-coated quartzes by QCM observing frequency shifts. CD36-expressing cell membrane fragments and CSA polysaccharide were coated via poly-l-lysine to the quartz. The method was validated by microscopic counting of attached parasites and of erythrocytes to the coated quartzes. Results Frequency shifts indicating binding of infected erythrocytes could be observed for both receptors CD36 and CSA. The frequency shifts seen for infected and uninfected erythrocytes were strongly correlated to the microscopically counted numbers of attached cells. Conclusions In this proof-of-concept experiment it is shown that QCM is a promising tool to measure binding kinetics and specificity of ligand-receptor interactions using viable, parasite-infected erythrocytes. The method can improve the understanding of the virulence of P. falciparum and might be used to cross-validate other methods. Electronic supplementary material The online version of this article (doi:10.1186/s12936-016-1374-7) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Daniela Kömpf
- Biosensor Research Group, Institute of Clinical and Experimental Transfusion Medicine, University Hospital of Tübingen, Tübingen, Germany.,State Health Office Baden-Württemberg, Stuttgart, Germany
| | - Jana Held
- Institute of Tropical Medicine, University of Tübingen, Tübingen, Germany. .,DZIF-Deutsches Zentrum für Infektionsforschung, Standort Tübingen, Germany.
| | - Stefani F Müller
- Biosensor Research Group, Institute of Clinical and Experimental Transfusion Medicine, University Hospital of Tübingen, Tübingen, Germany
| | - Hartmut R Drechsel
- Biosensor Research Group, Institute of Clinical and Experimental Transfusion Medicine, University Hospital of Tübingen, Tübingen, Germany.,3T GmbH & Co KG, Tuttlingen, Germany
| | - Serena C Tschan
- Institute of Tropical Medicine, University of Tübingen, Tübingen, Germany.,DZIF-Deutsches Zentrum für Infektionsforschung, Standort Tübingen, Germany
| | - Hinnak Northoff
- Biosensor Research Group, Institute of Clinical and Experimental Transfusion Medicine, University Hospital of Tübingen, Tübingen, Germany
| | - Benjamin Mordmüller
- Institute of Tropical Medicine, University of Tübingen, Tübingen, Germany.,DZIF-Deutsches Zentrum für Infektionsforschung, Standort Tübingen, Germany
| | - Frank K Gehring
- Biosensor Research Group, Institute of Clinical and Experimental Transfusion Medicine, University Hospital of Tübingen, Tübingen, Germany. .,3T GmbH & Co KG, Tuttlingen, Germany.
| |
Collapse
|
10
|
Microfluidics for simultaneous quantification of platelet adhesion and blood viscosity. Sci Rep 2016; 6:24994. [PMID: 27118101 PMCID: PMC4846989 DOI: 10.1038/srep24994] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2016] [Accepted: 04/08/2016] [Indexed: 12/14/2022] Open
Abstract
Platelet functions, including adhesion, activation, and aggregation have an influence on thrombosis and the progression of atherosclerosis. In the present study, a new microfluidic-based method is proposed to estimate platelet adhesion and blood viscosity simultaneously. Blood sample flows into an H-shaped microfluidic device with a peristaltic pump. Since platelet aggregation may be initiated by the compression of rotors inside the peristaltic pump, platelet aggregates may adhere to the H-shaped channel. Through correlation mapping, which visualizes decorrelation of the streaming blood flow, the area of adhered platelets (APlatelet) can be estimated without labeling platelets. The platelet function is estimated by determining the representative index IA·T based on APlatelet and contact time. Blood viscosity is measured by monitoring the flow conditions in the one side channel of the H-shaped device. Based on the relation between interfacial width (W) and pressure ratio of sample flows to the reference, blood sample viscosity (μ) can be estimated by measuring W. Biophysical parameters (IA·T, μ) are compared for normal and diabetic rats using an ex vivo extracorporeal model. This microfluidic-based method can be used for evaluating variations in the platelet adhesion and blood viscosity of animal models with cardiovascular diseases under ex vivo conditions.
Collapse
|
11
|
Utilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods. SENSORS 2016; 16:282. [PMID: 26927107 PMCID: PMC4813857 DOI: 10.3390/s16030282] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2015] [Revised: 02/15/2016] [Accepted: 02/18/2016] [Indexed: 01/19/2023]
Abstract
The determination of fibrinogen levels is one of the most important coagulation measurements in medicine. It plays a crucial part in diagnostic and therapeutic decisions, often associated with time-critical conditions. The commonly used measurement is the Clauss fibrinogen assay (CFA) where plasma is activated by thrombin reagent and which is conducted by mechanical/turbidimetric devices. As quartz crystal microbalance sensors with dissipation (QCM-D) based devices have a small footprint, can be operated easily and allow measurements independently from sample transportation time, laboratory location, availability and opening hours, they offer a great opportunity to complement laboratory CFA measurements. Therefore, the objective of the work was to (1) transfer the CFA to the QCM-D method; (2) develop an easy, time- and cost-effective procedure and (3) compare the results with references. Different sensor coatings (donor’s own plasma; gold surface) and different QCM-D parameters (frequency signal shift; its calculated turning point; dissipation signal shift) were sampled. The results demonstrate the suitability for a QCM-D-based CFA in physiological fibrinogen ranges. Results were obtained in less than 1 min and in very good agreement with a standardized reference (Merlin coagulometer). The results provide a good basis for further investigation and pave the way to a possible application of QCM-D in clinical and non-clinical routine in the medical field.
Collapse
|
12
|
Samuel SP, Santos-Martinez MJ, Medina C, Jain N, Radomski MW, Prina-Mello A, Volkov Y. CdTe quantum dots induce activation of human platelets: implications for nanoparticle hemocompatibility. Int J Nanomedicine 2015; 10:2723-34. [PMID: 25897218 PMCID: PMC4396453 DOI: 10.2147/ijn.s78281] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
New nanomaterials intended for systemic administration have raised concerns regarding their biocompatibility and hemocompatibility. Quantum dots (QD) nanoparticles have been used for diagnostics, and recent work suggests their use for in vivo molecular and cellular imaging. However, the hemocompatibility of QDs and their constituent components has not been fully elucidated. In the present study, comprehensive investigation of QD–platelet interactions is presented. These interactions were shown using transmission electron microscopy. The effects of QDs on platelet function were investigated using light aggregometry, quartz crystal microbalance with dissipation, flow cytometry, and gelatin zymography. Platelet morphology was also analyzed by phase-contrast, immunofluorescence, atomic-force and transmission electron microscopy. We show that the QDs bind to platelet plasma membrane with the resultant upregulation of glycoprotein IIb/IIIa and P-selectin receptors, and release of matrix metalloproteinase-2. These findings unravel for the first time the mechanism of functional response of platelets to ultrasmall QDs in vitro.
Collapse
Affiliation(s)
- Stephen P Samuel
- Department of Clinical Medicine, Institute of Molecular Medicine, Trinity College Dublin, Dublin, Ireland
| | - Maria J Santos-Martinez
- School of Pharmacy and Pharmaceutical Sciences, Trinity College Dublin, Dublin, Ireland ; Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin, Ireland ; School of Medicine, Trinity College Dublin, Dublin, Ireland
| | - Carlos Medina
- School of Pharmacy and Pharmaceutical Sciences, Trinity College Dublin, Dublin, Ireland ; Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin, Ireland
| | - Namrata Jain
- Department of Clinical Medicine, Institute of Molecular Medicine, Trinity College Dublin, Dublin, Ireland
| | - Marek W Radomski
- School of Pharmacy and Pharmaceutical Sciences, Trinity College Dublin, Dublin, Ireland ; Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin, Ireland
| | - Adriele Prina-Mello
- Department of Clinical Medicine, Institute of Molecular Medicine, Trinity College Dublin, Dublin, Ireland ; AMBER and CRANN, Trinity College Dublin, Dublin, Ireland
| | - Yuri Volkov
- Department of Clinical Medicine, Institute of Molecular Medicine, Trinity College Dublin, Dublin, Ireland ; AMBER and CRANN, Trinity College Dublin, Dublin, Ireland
| |
Collapse
|
13
|
Hussain M, Northoff H, Gehring FK. QCM-D providing new horizon in the domain of sensitivity range and information for haemostasis of human plasma. Biosens Bioelectron 2014; 66:579-84. [PMID: 25530537 DOI: 10.1016/j.bios.2014.12.003] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2014] [Revised: 11/23/2014] [Accepted: 12/01/2014] [Indexed: 10/24/2022]
Abstract
Monitoring of the haemostasis status is significant for proper therapeutic directions and decisions in surgery and innate coagulation disorders. In this regard, to gain a general overview of the plasmatic coagulation, prothrombin time (PT) tests are frequently combined with tests for activated partial thromboplastin time (aPTT). For aPTT we report for the first time that a QCM-D (Quartz Crystal Microbalances with Dissipation) based technique offers a better alternative to the standard coagulometer method in the perspective of range and information. We used heparin as anticoagulant to generate different coagulation times for human plasma. QCM-D astonishingly proved to be more sensitive and reliable than the standard coagulometer for aPTT range of upper limits of coagulation times. The established platform can monitor the fibrinogen concentration ranging from 1-6g/L (yielding R(2)=0.98 in calibration curves) along with aPTT from frequency and dissipation shifts together in a single set of measurements. Additionally the sensor layers have been tested for reusability, demonstrating no loss in sensor characteristics up to ten times measurements.
Collapse
Affiliation(s)
- Munawar Hussain
- Biosensor Research Group, Institute of Clinical and Experimental Transfusion Medicine and Centre of Clinical Transfusion Medicine (ZKT), Tuebingen University and German Red Cross Blood Transfusion Service BW/H, Germany.
| | - Hinnak Northoff
- Biosensor Research Group, Institute of Clinical and Experimental Transfusion Medicine and Centre of Clinical Transfusion Medicine (ZKT), Tuebingen University and German Red Cross Blood Transfusion Service BW/H, Germany
| | - Frank K Gehring
- Biosensor Research Group, Institute of Clinical and Experimental Transfusion Medicine and Centre of Clinical Transfusion Medicine (ZKT), Tuebingen University and German Red Cross Blood Transfusion Service BW/H, Germany.
| |
Collapse
|
14
|
Krajewski S, Rheinlaender J, Ries P, Canjuga D, Mack C, Scheideler L, Schäffer TE, Geis-Gerstorfer J, Wendel HP, Rupp F. Bacterial interactions with proteins and cells relevant to the development of life-threatening endocarditis studied by use of a quartz-crystal microbalance. Anal Bioanal Chem 2014; 406:3395-406. [DOI: 10.1007/s00216-014-7769-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2014] [Revised: 03/12/2014] [Accepted: 03/16/2014] [Indexed: 12/17/2022]
|
15
|
Kunze A, Hesse C, Svedhem S. Real-time monitoring of surface-confined platelet activation on TiO2. Colloids Surf B Biointerfaces 2014; 116:446-51. [DOI: 10.1016/j.colsurfb.2014.01.025] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2013] [Revised: 01/10/2014] [Accepted: 01/19/2014] [Indexed: 10/25/2022]
|
16
|
Harris LF, Castro-López V, Killard AJ. Coagulation monitoring devices: Past, present, and future at the point of care. Trends Analyt Chem 2013. [DOI: 10.1016/j.trac.2013.05.009] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
17
|
Meyer Dos Santos S, Zorn A, Guttenberg Z, Picard-Willems B, Kläffling C, Nelson K, Klinkhardt U, Harder S. A novel μ-fluidic whole blood coagulation assay based on Rayleigh surface-acoustic waves as a point-of-care method to detect anticoagulants. BIOMICROFLUIDICS 2013; 7:56502. [PMID: 24404078 PMCID: PMC3799685 DOI: 10.1063/1.4824043] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2013] [Accepted: 09/19/2013] [Indexed: 05/10/2023]
Abstract
A universal coagulation test that reliably detects prolonged coagulation time in patients, irrespective of the anticoagulant administered, has not been available to date. An easily miniaturised, novel μ-fluidic universal coagulation test employing surface acoustic waves (SAW) is presented here. SAW was employed to instantly mix and recalcify 6 μl citrated whole blood and image correlation analysis was used to quantify clot formation kinetics. The detection of clinically relevant anticoagulant dosing with old anticoagulants (unfractionated heparin, argatroban) and new anticoagulants (dabigatran, rivaroxaban) has been tested and compared to standard plasma coagulation assays. The applicability of this novel method has been confirmed in a small patient population. Coagulation was dose-proportionally prolonged with heparin, argatroban, dabigatran, and rivaroxaban, comparable to standard tests. Aspirin and clopidogrel did not interfere with the SAW-induced clotting time (SAW-CT), whereas the strong GPIIb/IIIa-inhibitor abciximab did interfere. Preliminary clinical data prove the suitability of the SAW-CT in patients being treated with warfarin, rivaroxaban, or dabigatran. The system principally allows assessment of whole blood coagulation in humans in a point-of-care setting. This method could be used in stroke units, emergency vehicles, general and intensive care wards, as well as for laboratory and home testing of coagulation.
Collapse
Affiliation(s)
- Sascha Meyer Dos Santos
- J.W. Goethe University Hospital, Institute for Clinical Pharmacology, Theodor-Stern-Kai 7 60590 Frankfurt
| | - Anita Zorn
- J.W. Goethe University Hospital, Institute for Clinical Pharmacology, Theodor-Stern-Kai 7 60590 Frankfurt
| | | | - Bettina Picard-Willems
- J.W. Goethe University Hospital, Institute for Clinical Pharmacology, Theodor-Stern-Kai 7 60590 Frankfurt
| | - Christina Kläffling
- J.W. Goethe University Hospital, Center for Internal Medicine-Cardiology, Theodor-Stern-Kai 7 60590 Frankfurt
| | - Karen Nelson
- J.W. Goethe University Hospital, Department of Vascular and Endovascular Surgery, Theodor-Stern-Kai 7 60590 Frankfurt
| | - Ute Klinkhardt
- J.W. Goethe University Hospital, Institute for Clinical Pharmacology, Theodor-Stern-Kai 7 60590 Frankfurt
| | - Sebastian Harder
- J.W. Goethe University Hospital, Institute for Clinical Pharmacology, Theodor-Stern-Kai 7 60590 Frankfurt
| |
Collapse
|
18
|
Speight RE, Cooper MA. A Survey of the 2010 Quartz Crystal Microbalance Literature. J Mol Recognit 2012; 25:451-73. [DOI: 10.1002/jmr.2209] [Citation(s) in RCA: 104] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Affiliation(s)
- Robert E. Speight
- Institute for Molecular Bioscience; The University of Queensland; St. Lucia; Brisbane; 4072; Australia
| | - Matthew A. Cooper
- Institute for Molecular Bioscience; The University of Queensland; St. Lucia; Brisbane; 4072; Australia
| |
Collapse
|
19
|
Westein E, de Witt S, Lamers M, Cosemans JMEM, Heemskerk JWM. Monitoring in vitro thrombus formation with novel microfluidic devices. Platelets 2012; 23:501-9. [PMID: 22873212 DOI: 10.3109/09537104.2012.709653] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Cardiovascular disease is a major cause of mortality globally and is subject to ongoing research to improve clinical treatment. It is established that activation of platelets and coagulation are central to thrombosis, yet at different extents in the arterial and venous system. In vitro perfusion chamber technology has contributed significant knowledge on the function of platelets in the thrombotic process under shear conditions. Recent efforts to downscale this technique with a variety of microfluidic devices has opened new possibilities to study this process under precisely controlled flow conditions. Such microfluidic devices possess the capability to execute platelet function tests more quickly than current assays, while using small blood samples. Gradually becoming available to the clinic now, they may provide a new means to manage the treatment of cardiovascular diseases, although accurate validation studies still are missing. This review highlights the progress that has been made in monitoring aspects of thrombus formation using microfluidic devices.
Collapse
Affiliation(s)
- Erik Westein
- Department of Biochemistry, CARIM, Maastricht University, Maastricht, The Netherlands.
| | | | | | | | | |
Collapse
|
20
|
Santos-Martinez MJ, Inkielewicz-Stepniak I, Medina C, Rahme K, D'Arcy DM, Fox D, Holmes JD, Zhang H, Radomski MW. The use of quartz crystal microbalance with dissipation (QCM-D) for studying nanoparticle-induced platelet aggregation. Int J Nanomedicine 2012; 7:243-55. [PMID: 22275839 PMCID: PMC3263416 DOI: 10.2147/ijn.s26679] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
Interactions between blood platelets and nanoparticles have both pharmacological and toxicological significance and may lead to platelet activation and aggregation. Platelet aggregation is usually studied using light aggregometer that neither mimics the conditions found in human microvasculature nor detects microaggregates. A new method for the measurement of platelet microaggregation under flow conditions using a commercially available quartz crystal microbalance with dissipation (QCM-D) has recently been developed. The aim of the current study was to investigate if QCM-D could be used for the measurement of nanoparticle-platelet interactions. Silica, polystyrene, and gold nanoparticles were tested. The interactions were also studied using light aggregometry and flow cytometry, which measured surface abundance of platelet receptors. Platelet activation was imaged using phase contrast and scanning helium ion microscopy. QCM-D was able to measure nanoparticle-induced platelet microaggregation for all nanoparticles tested at concentrations that were undetectable by light aggregometry and flow cytometry. Microaggregates were measured by changes in frequency and dissipation, and the presence of platelets on the sensor surface was confirmed and imaged by phase contrast and scanning helium ion microscopy.
Collapse
|
21
|
NCO-sP(EO-stat-PO) coatings on gold sensors--a QCM study of hemocompatibility. SENSORS 2011; 11:5253-69. [PMID: 22163899 PMCID: PMC3231391 DOI: 10.3390/s110505253] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/25/2011] [Revised: 04/19/2011] [Accepted: 05/09/2011] [Indexed: 11/17/2022]
Abstract
The reliability of implantable blood sensors is often hampered by unspecific adsorption of plasma proteins and blood cells. This not only leads to a loss of sensor signal over time, but can also result in undesired host vs. graft reactions. Within this study we evaluated the hemocompatibility of isocyanate conjugated star shaped polytheylene oxide-polypropylene oxide co-polymers NCO-sP(EO-stat-PO) when applied to gold surfaces as an auspicious coating material for gold sputtered blood contacting sensors. Quartz crystal microbalance (QCM) sensors were coated with ultrathin NCO-sP(EO-stat-PO) films and compared with uncoated gold sensors. Protein resistance was assessed by QCM measurements with fibrinogen solution and platelet poor plasma (PPP), followed by quantification of fibrinogen adsorption. Hemocompatibility was tested by incubation with human platelet rich plasma (PRP). Thrombin antithrombin-III complex (TAT), β-thromboglobulin (β-TG) and platelet factor 4 (PF4) were used as coagulation activation markers. Furthermore, scanning electron microscopy (SEM) was used to visualize platelet adhesion to the sensor surfaces. Compared to uncoated gold sensors, NCO-sP(EO-stat-PO) coated sensors revealed significant better resistance against protein adsorption, lower TAT generation and a lower amount of adherent platelets. Moreover, coating with ultrathin NCO-sP(EO-stat-PO) films creates a cell resistant hemocompatible surface on gold that increases the chance of prolonged sensor functionality and can easily be modified with specific receptor molecules.
Collapse
|
22
|
Santos-Martínez MJ, Prina-Mello A, Medina C, Radomski MW. Analysis of platelet function: role of microfluidics and nanodevices. Analyst 2011; 136:5120-6. [DOI: 10.1039/c1an15445a] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|