1
|
Hasan MR, Singh S, Sharma P, Azmi Z, Dadial AS, Narang J. Kirigami tripod-based electrode for the development of highly stretchable dengue aptasensor. Biomed Microdevices 2024; 26:21. [PMID: 38558326 DOI: 10.1007/s10544-024-00704-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/22/2024] [Indexed: 04/04/2024]
Abstract
Kirigami is one of the interesting paper art forms and the modified sub-class of origami. Kirigami paper art is widely employed in a variety of applications, and it is currently being used in biosensors because of its outstanding advantages. This is the first study on the use of a Kirigami-based aptasensor for DENV (Dengue virus)-antigen detection. In this study, the kirigami approach has been utilized to develop a stretchable, movable, and flexible sensor. The constructed stretchable-kirigami electrode helps in adjusting the connection of electrodes without disturbing the electrochemical cell zone during the experiment. To increase the sensitivity of this biosensor we have synthesized Ag-NPs (Silver nanoparticles) via chemical methods and characterized their results with the help of TEM & UV-Vis Spectroscopy. Different electrochemical approaches were used to validate the sensor response i.e., CV (Cyclic voltammetry) and LSV (Linear sweep voltammetry), which exhibited great detection capability towards dengue virus with the range of 0.1 µg/ml to 1000 µg/ml along with a detection limit of 0.1 µg/ml and showing no reactivity to the chikungunya virus antigen, making it more specific to the DENV antigen. Serum (healthy-human) was also successfully applied to validate the results of the constructed aptasensor. Integration of the Kirigami approach form with the electrochemical aptasensor that utilizes a 3-E setup (three-electrode setup) which is referred to as a tripod and collectively called Kirigami-tripod-based aptasensor. Thus, the developed integrated platform improves the sensors capabilities in terms of cost efficiency, high stretchability, and sensitivity.
Collapse
Affiliation(s)
- Mohd Rahil Hasan
- Department of Biotechnology, Jamia Hamdard, New Delhi 110062, India
| | - Saumitra Singh
- Department of Biotechnology, Jamia Hamdard, New Delhi 110062, India
| | | | - Zaira Azmi
- Department of Biotechnology, Jamia Hamdard, New Delhi 110062, India
| | | | - Jagriti Narang
- Department of Biotechnology, Jamia Hamdard, New Delhi 110062, India.
| |
Collapse
|
2
|
Li X, Wang Y, Zhang X, Gao Y, Sun C, Ding Y, Feng F, Jin W, Yang G. An impedimetric immunosensor for determination of porcine epidemic diarrhea virus based on the nanocomposite consisting of molybdenum disulfide/reduced graphene oxide decorated with gold nanoparticles. Mikrochim Acta 2020; 187:217. [PMID: 32166419 DOI: 10.1007/s00604-020-4166-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2019] [Accepted: 02/13/2020] [Indexed: 01/03/2023]
Abstract
An electrochemical immunosensor for the determination of porcine epidemic diarrhea virus (PEDV) is described. It was manufactured by using gold nanoparticles/molybdenum disulfide/reduced graphene oxide nanocomposites modified on the surface of a glassy carbon electrode (GCE). The independently developed monoclonal antibody of PEDV-2C11 was immobilized on the modified electrode at site of gold nanoparticles provided in the nanocomposites. The concentration of PEDV was quantified by measuring the changes in the charge transfer resistance of the electrode before and after the immunoreaction between antigen-antibody by using hexacyanoferrate(II)/(III) as the redox probe. The frequency range was 10-1 to 105 Hz at the amplitude of 10 mV and an applied potential of + 0.180 V. Based on the immunoreaction between PEDV antigen and PEDV-2C11 antibody in 0.1 M phosphate buffer containing 0.1 M KCl at 37.5 °C for 140 min, the relative change in impedance was proportional to the logarithmic value of PEDV concentrations in the range of 82.5 to 1.65 × 104 TCID50 mL-1. Good reproducibility, stability, and specificity of the proposed immunosensor were obtained. It was successfully applied to the determination of PEDV in the spiked sample. Graphical abstractSchematic representation. a The preparation of AuNP/MoS2/rGO composites. b Representation of modification and functioning of the label-free electrochemical immunosensor and the electrochemical impedimetric response obtained before (a) and after (b) incubation of PEDV.
Collapse
Affiliation(s)
- Xiaotong Li
- Key Laboratory of Drug Quality Control and Pharmacovigilance (China Pharmaceutical University), Ministry of Education, School of Pharmacy, China Pharmaceutical University, 210009, Nanjing, People's Republic of China
| | - Yanchun Wang
- College of Veterinary Medicine, Ministry of Education key laboratory of poultry preventive medicine, Yangzhou University, 225002, Yangzhou, People's Republic of China
| | - Xiaolei Zhang
- Key Laboratory of Drug Quality Control and Pharmacovigilance (China Pharmaceutical University), Ministry of Education, School of Pharmacy, China Pharmaceutical University, 210009, Nanjing, People's Republic of China
| | - Ye Gao
- Key Laboratory of Drug Quality Control and Pharmacovigilance (China Pharmaceutical University), Ministry of Education, School of Pharmacy, China Pharmaceutical University, 210009, Nanjing, People's Republic of China
| | - Chenmin Sun
- College of Chemistry and Chemical Engineering, Yangzhou University, 225002, Yangzhou, People's Republic of China
| | - Yuanhua Ding
- College of Chemistry and Chemical Engineering, Yangzhou University, 225002, Yangzhou, People's Republic of China
| | - Fang Feng
- Key Laboratory of Drug Quality Control and Pharmacovigilance (China Pharmaceutical University), Ministry of Education, School of Pharmacy, China Pharmaceutical University, 210009, Nanjing, People's Republic of China.
| | - Wenjie Jin
- College of Veterinary Medicine, Ministry of Education key laboratory of poultry preventive medicine, Yangzhou University, 225002, Yangzhou, People's Republic of China.
| | - Gongjun Yang
- Key Laboratory of Drug Quality Control and Pharmacovigilance (China Pharmaceutical University), Ministry of Education, School of Pharmacy, China Pharmaceutical University, 210009, Nanjing, People's Republic of China.
| |
Collapse
|
3
|
Anusha JR, Kim BC, Yu KH, Raj CJ. Electrochemical biosensing of mosquito-borne viral disease, dengue: A review. Biosens Bioelectron 2019; 142:111511. [PMID: 31319325 DOI: 10.1016/j.bios.2019.111511] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2019] [Revised: 06/21/2019] [Accepted: 07/12/2019] [Indexed: 02/07/2023]
Abstract
Dengue virus is a mosquito-borne, single positive-stranded RNA virus that spread human being through infected female Aedes mosquito bite and causes dengue fever. The demand for early detection of this virus has increased to control the widespread of infectious diseases and protect humankind from its harmful effects. Recently, biosensors are found to the potential tool to detect and quantify the virus with fast detection, relatively cost-effective, high sensitivity and selectivity than the conventional diagnostic methods such as immunological and molecular techniques. Mostly, the biosensors employ electrochemical detection technique with transducers, owing to its easy construction, low-cost, ease of use, and portability. Here, we review the current trends and advancement in the electrochemical diagnosis of dengue virus and discussed various types of electrochemical biosensing techniques such as; amperometric, potentiometric, impedometric, and voltammetric sensing. Apart from these, we discussed the role of biorecognition molecules such as nucleic acid, antibodies, and lectins in electrochemical sensing of dengue virus. In addition, the review highlighted the benefits of the electrochemical approach in comparison with traditional diagnostic methods. We expect that these dengue virus diagnostic techniques will continue to evolve and grow in future, with exciting new possibilities stemming from advancement in the rational design of electrochemical biosensors.
Collapse
Affiliation(s)
- J R Anusha
- Department of Chemistry, Dongguk University, Jung-gu, Seoul, 04620, Republic of Korea; Department of Advanced Zoology and Biotechnology, Loyola College, Chennai, 600034, Tamil Nadu, India
| | - Byung Chul Kim
- Department of Printed Electronics Engineering, Sunchon National University, 255, Jungang-ro, Suncheon-si, Jellanamdo, 57922, Republic of Korea
| | - Kook-Hyun Yu
- Department of Chemistry, Dongguk University, Jung-gu, Seoul, 04620, Republic of Korea
| | - C Justin Raj
- Department of Chemistry, Dongguk University, Jung-gu, Seoul, 04620, Republic of Korea.
| |
Collapse
|
4
|
Effects of redox label location on the performance of an electrochemical aptamer-based tumor necrosis factor-alpha sensor. Talanta 2018; 189:585-591. [PMID: 30086964 DOI: 10.1016/j.talanta.2018.07.055] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2018] [Revised: 07/16/2018] [Accepted: 07/17/2018] [Indexed: 11/21/2022]
Abstract
We report the development of an electrochemical aptamer-based sensor for real time detection of tumor necrosis factor-alpha. The focus of this study is to evaluate the effects of the redox label location on the overall sensor performance, including sensor stability, detection limit, reusability, and selectivity. Three aptamer probes, each labeled with methylene blue (MB) at a specific location, were designed and employed in the fabrication of the sensors. Among the three sensors, the sensor fabricated using an aptamer with the MB label located at the distal end has a detection limit of 100 pM and is regenerable. The sensor fabricated using an aptamer with an internal MB modification has a detection limit of 10 nM and is not regenerable. Both sensors can be employed in complex biological samples such as 50% urine and 50% saliva. However, the sensor fabricated with an aptamer with the MB label located at the proximal end suffers from poor reproducibility and is highly unstable, thus limiting its application as a sensor. On the bases of these results, placing the MB label at the distal end of the aptamer probe appears to be the most advantageous for this sensor design for it does not interfere with monolayer formation and target binding.
Collapse
|
5
|
Aydın EB, Sezgintürk MK. An impedimetric immunosensor for highly sensitive detection of IL-8 in human serum and saliva samples: A new surface modification method by 6-phosphonohexanoic acid for biosensing applications. Anal Biochem 2018; 554:44-52. [PMID: 29902421 DOI: 10.1016/j.ab.2018.05.030] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2018] [Revised: 05/27/2018] [Accepted: 05/30/2018] [Indexed: 11/30/2022]
Abstract
In this study, we fabricated a sensitive and label-free impedimetric immunosensor based on 6-phosphonohexanoic acid (PHA) modified ITO electrode for detection of interleukin-8 (IL-8) in human serum and saliva. PHA was first employed to cancer biomarker sensing platform. Anti-IL-8 antibody was used as a biorecognition element and the detection principle of this immunosensor was based on monitoring specific interaction between anti-IL-8 antibody and IL-8 antigen. The morphological characterization of each electrode modification step was analyzed by scanning electron microscopy (SEM), SEM-energy dispersive X-ray spectroscopy (EDX) and atomic force microscopy (AFM) while electrochemical characterization was performed by electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and single frequency impedance (SFI) techniques. Moreover, the antibody immobilization on the electrode surface was proved Fourier-transform infrared spectroscopy (FTIR) and Raman Spectroscopy. This proposed impedimetric immunosensor exhibited good performances with a wide linear in the range from 0.02 pg/mL to 3 pg/mL as well as a relative low detection limit of 6 fg/mL. The impedimetric immunosensor had a good specificity, stability and reproducibility. This study proved that PHA was a suitable interface material to fabricate an electrochemical biosensor.
Collapse
Affiliation(s)
- Elif Burcu Aydın
- Namık Kemal University, Scientific and Technological Research Center, Tekirdağ, Turkey.
| | - Mustafa Kemal Sezgintürk
- Çanakkale Onsekiz Mart University, Faculty of Engineering, Bioengineering Department, Çanakkale, Turkey
| |
Collapse
|
6
|
Safavieh M, Kaul V, Khetani S, Singh A, Dhingra K, Kanakasabapathy MK, Draz MS, Memic A, Kuritzkes DR, Shafiee H. Paper microchip with a graphene-modified silver nano-composite electrode for electrical sensing of microbial pathogens. NANOSCALE 2017; 9:1852-1861. [PMID: 27845796 PMCID: PMC5695240 DOI: 10.1039/c6nr06417e] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Rapid and sensitive point-of-care diagnostics are of paramount importance for early detection of infectious diseases and timely initiation of treatment. Here, we present cellulose paper and flexible plastic chips with printed graphene-modified silver electrodes as universal point-of-care diagnostic tools for the rapid and sensitive detection of microbial pathogens or nucleic acids through utilizing electrical sensing modality and loop-mediated isothermal amplification (LAMP). We evaluated the ability of the developed paper-based assay to detect (i) viruses on cellulose-based paper microchips without implementing amplification in samples with viral loads between 106 and 108 copies per ml, and (ii) amplified HIV-1 nucleic acids in samples with viral loads between 10 fg μl-1 and 108 fg μl-1. The target HIV-1 nucleic acid was amplified using the RT-LAMP technique and detected through the electrical sensing of LAMP amplicons for a broad range of RNA concentrations between 10 fg μl-1 and 108 fg μl-1 after 40 min of amplification time. Our assay may be used for antiretroviral therapy monitoring where it meets the sensitivity requirement of the World Health Organization guidelines. Such a paper microchip assay without the amplification step may also be considered as a simple and inexpensive approach for acute HIV detection where maximum viral replication occurs.
Collapse
Affiliation(s)
- Mohammadali Safavieh
- Division of Engineering in Medicine, Division of Renal Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
| | - Vivasvat Kaul
- Division of Engineering in Medicine, Division of Renal Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
| | - Sultan Khetani
- Division of Engineering in Medicine, Division of Renal Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
| | - Anupriya Singh
- Division of Engineering in Medicine, Division of Renal Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
| | - Karan Dhingra
- Division of Engineering in Medicine, Division of Renal Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
| | - Manoj Kumar Kanakasabapathy
- Division of Engineering in Medicine, Division of Renal Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
| | - Mohamed Shehata Draz
- Division of Engineering in Medicine, Division of Renal Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA. and Faculty of Science, Tanta University, Tanta 31527, Egypt
| | - Adnan Memic
- Center for Nanotechnology, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Daniel R Kuritzkes
- Division of Infectious Diseases, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA and Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA
| | - Hadi Shafiee
- Division of Engineering in Medicine, Division of Renal Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA. and Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA
| |
Collapse
|
7
|
González-Fernández E, Avlonitis N, Murray AF, Mount AR, Bradley M. Methylene blue not ferrocene: Optimal reporters for electrochemical detection of protease activity. Biosens Bioelectron 2016; 84:82-8. [DOI: 10.1016/j.bios.2015.11.088] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2015] [Revised: 11/24/2015] [Accepted: 11/27/2015] [Indexed: 01/08/2023]
|
8
|
Labib M, Sargent EH, Kelley SO. Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules. Chem Rev 2016; 116:9001-90. [DOI: 10.1021/acs.chemrev.6b00220] [Citation(s) in RCA: 555] [Impact Index Per Article: 61.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Mahmoud Labib
- Department
of Pharmaceutical Sciences, University of Toronto, Toronto, Ontario M5S 3M2, Canada
| | | | - Shana O. Kelley
- Department
of Pharmaceutical Sciences, University of Toronto, Toronto, Ontario M5S 3M2, Canada
- Institute
of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario M5S 3G4, Canada
| |
Collapse
|
9
|
Zaitouna AJ, Maben AJ, Lai RY. Incorporation of extra amino acids in peptide recognition probe to improve specificity and selectivity of an electrochemical peptide-based sensor. Anal Chim Acta 2015; 886:157-64. [PMID: 26320648 DOI: 10.1016/j.aca.2015.05.037] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2015] [Revised: 05/17/2015] [Accepted: 05/18/2015] [Indexed: 10/23/2022]
Abstract
We investigated the effect of incorporating extra amino acids (AA) at the n-terminus of the thiolated and methylene blue-modified peptide probe on both specificity and selectivity of an electrochemical peptide-based (E-PB) HIV sensor. The addition of a flexible (SG)3 hexapeptide is, in particular, useful in improving sensor selectivity, whereas the addition of a highly hydrophilic (EK)3 hexapeptide has shown to be effective in enhancing sensor specificity. Overall, both E-PB sensors fabricated using peptide probes with the added AA (SG-EAA and EK-EAA) showed better specificity and selectivity, especially when compared to the sensor fabricated using a peptide probe without the extra AA (EAA). For example, the selectivity factor recorded in the 50% saliva was ∼2.5 for the EAA sensor, whereas the selectivity factor was 7.8 for both the SG-EAA and EK-EAA sensors. Other sensor properties such as the limit of detection and dynamic range were minimally affected by the addition of the six AA sequence. The limit of detection was 0.5 nM for the EAA sensor and 1 nM for both SG-EAA and EK-EAA sensors. The saturation target concentration was ∼200 nM for all three sensors. Unlike previously reported E-PB HIV sensors, the peptide probe functions as both the recognition element and antifouling passivating agent; this modification eliminates the need to include an additional antifouling diluent, which simplifies the sensor design and fabrication protocol.
Collapse
Affiliation(s)
- Anita J Zaitouna
- University of Nebraska-Lincoln, 651 Hamilton Hall, Lincoln, NE 68588-0304, USA
| | - Alex J Maben
- University of Nebraska-Lincoln, 651 Hamilton Hall, Lincoln, NE 68588-0304, USA
| | - Rebecca Y Lai
- University of Nebraska-Lincoln, 651 Hamilton Hall, Lincoln, NE 68588-0304, USA.
| |
Collapse
|
10
|
Zaitouna AJ, Joyce J, Cerny RL, Dussault PH, Lai RY. Comparison of Mannose, Ethylene Glycol, and Methoxy-Terminated Diluents on Specificity and Selectivity of Electrochemical Peptide-Based Sensors. Anal Chem 2015; 87:6966-73. [PMID: 26057465 DOI: 10.1021/acs.analchem.5b01759] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
We report the synthesis and application of three new antifouling diluents for the fabrication of an E-PB HIV sensor. Among the three thiolated antifouling diluents used in this study, the methoxy-terminated diluent (C6-MEG) is the most effective in alleviating both nonspecific binding and adsorption of matrix contaminants onto the sensor surface, especially when compared to the mannose- (C6-MAN) and ethylene-glycol-terminated (C6-EG) diluents. The sensor fabricated with C6-MEG has a specificity factor (∼13.5) substantially higher than the sensor passivated with only 6-mercapto-1-hexanol (∼1.5). It is functional even when employed directly in 25% serum, an achievement that has not been observed with this class of E-PB sensors. More importantly, incorporation of these antifouling diluents has negligible impact on other important sensor properties such as sensitivity and binding kinetics. This sensor passivation strategy is versatile and can potentially be used with other E-PB sensors, as well as surface-based sensors that utilize thiol-gold self-assembled monolayer chemistry.
Collapse
Affiliation(s)
- Anita J Zaitouna
- †Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska 68588-0304, United States
| | - Jesse Joyce
- †Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska 68588-0304, United States
| | - Ronald L Cerny
- †Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska 68588-0304, United States
| | - Patrick H Dussault
- †Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska 68588-0304, United States
| | - Rebecca Y Lai
- †Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska 68588-0304, United States
| |
Collapse
|
11
|
Shafiee H, Kanakasabapathy MK, Juillard F, Keser M, Sadasivam M, Yuksekkaya M, Hanhauser E, Henrich TJ, Kuritzkes DR, Kaye KM, Demirci U. Printed Flexible Plastic Microchip for Viral Load Measurement through Quantitative Detection of Viruses in Plasma and Saliva. Sci Rep 2015; 5:9919. [PMID: 26046668 PMCID: PMC4456945 DOI: 10.1038/srep09919] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2014] [Accepted: 03/19/2015] [Indexed: 12/13/2022] Open
Abstract
We report a biosensing platform for viral load measurement through electrical sensing of viruses on a flexible plastic microchip with printed electrodes. Point-of-care (POC) viral load measurement is of paramount importance with significant impact on a broad range of applications, including infectious disease diagnostics and treatment monitoring specifically in resource-constrained settings. Here, we present a broadly applicable and inexpensive biosensing technology for accurate quantification of bioagents, including viruses in biological samples, such as plasma and artificial saliva, at clinically relevant concentrations. Our microchip fabrication is simple and mass-producible as we print microelectrodes on flexible plastic substrates using conductive inks. We evaluated the microchip technology by detecting and quantifying multiple Human Immunodeficiency Virus (HIV) subtypes (A, B, C, D, E, G, and panel), Epstein-Barr Virus (EBV), and Kaposi's Sarcoma-associated Herpes Virus (KSHV) in a fingerprick volume (50 µL) of PBS, plasma, and artificial saliva samples for a broad range of virus concentrations between 10(2) copies/mL and 10(7) copies/mL. We have also evaluated the microchip platform with discarded, de-identified HIV-infected patient samples by comparing our microchip viral load measurement results with reverse transcriptase-quantitative polymerase chain reaction (RT-qPCR) as the gold standard method using Bland-Altman Analysis.
Collapse
Affiliation(s)
- Hadi Shafiee
- Division of Biomedical Engineering, Division of Renal
Medicine, Department of Medicine, Brigham and Women’s Hospital,
Harvard Medical School, Boston, MA, USA
- Harvard-MIT Division of Health Sciences and
Technology, Cambridge, MA, USA
| | - Manoj Kumar Kanakasabapathy
- Division of Biomedical Engineering, Division of Renal
Medicine, Department of Medicine, Brigham and Women’s Hospital,
Harvard Medical School, Boston, MA, USA
- Harvard-MIT Division of Health Sciences and
Technology, Cambridge, MA, USA
| | - Franceline Juillard
- Department of Medicine, Brigham and Women’s
Hospital, Harvard Medical School, Boston, MA,
USA
| | - Mert Keser
- Division of Biomedical Engineering, Division of Renal
Medicine, Department of Medicine, Brigham and Women’s Hospital,
Harvard Medical School, Boston, MA, USA
- Harvard-MIT Division of Health Sciences and
Technology, Cambridge, MA, USA
| | - Magesh Sadasivam
- Division of Biomedical Engineering, Division of Renal
Medicine, Department of Medicine, Brigham and Women’s Hospital,
Harvard Medical School, Boston, MA, USA
- Harvard-MIT Division of Health Sciences and
Technology, Cambridge, MA, USA
| | - Mehmet Yuksekkaya
- Division of Biomedical Engineering, Division of Renal
Medicine, Department of Medicine, Brigham and Women’s Hospital,
Harvard Medical School, Boston, MA, USA
- Harvard-MIT Division of Health Sciences and
Technology, Cambridge, MA, USA
| | - Emily Hanhauser
- Division of Infectious Diseases, Brigham and
Women’s Hospital, Harvard Medical School, MA,
USA
| | - Timothy J. Henrich
- Division of Infectious Diseases, Brigham and
Women’s Hospital, Harvard Medical School, MA,
USA
| | - Daniel R. Kuritzkes
- Division of Infectious Diseases, Brigham and
Women’s Hospital, Harvard Medical School, MA,
USA
| | - Kenneth M. Kaye
- Department of Medicine, Brigham and Women’s
Hospital, Harvard Medical School, Boston, MA,
USA
| | - Utkan Demirci
- Division of Biomedical Engineering, Division of Renal
Medicine, Department of Medicine, Brigham and Women’s Hospital,
Harvard Medical School, Boston, MA, USA
- Department of Radiology, Canary Center at Stanford for
Cancer Early Detection, Stanford University School of Medicine, Palo Alto,
CA, USA
| |
Collapse
|
12
|
She Z, Topping K, Shamsi MH, Wang N, Chan NWC, Kraatz HB. Investigation of the Utility of Complementary Electrochemical Detection Techniques to Examine the in Vitro Affinity of Bacterial Flagellins for a Toll-Like Receptor 5 Biosensor. Anal Chem 2015; 87:4218-24. [DOI: 10.1021/ac5042439] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Affiliation(s)
- Zhe She
- Department
of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario M1C 1A4, Canada
- Department
of Chemistry, University of Toronto, 80 Saint George Street, Toronto, Ontario M5S 3H6, Canada
| | - Kristin Topping
- Department
of Chemistry and Chemical Engineering, Royal Military College of Canada, P.O. Box
17000, Station Forces, Kingston, Ontario K7K 7B4, Canada
| | - Mohtashim H. Shamsi
- Department
of Chemistry, University of Toronto, 80 Saint George Street, Toronto, Ontario M5S 3H6, Canada
- Donnelly Centre
for Cellular and Biomolecular Research, University of Toronto, 160 College
Street, Toronto, Ontario M5S 3E1, Canada
| | - Nan Wang
- Department
of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario M1C 1A4, Canada
- Department
of Chemistry, University of Toronto, 80 Saint George Street, Toronto, Ontario M5S 3H6, Canada
| | - Nora W. C. Chan
- Department
of Chemistry and Chemical Engineering, Royal Military College of Canada, P.O. Box
17000, Station Forces, Kingston, Ontario K7K 7B4, Canada
- Bio-Analysis
Group, Defence Research and Development Canada—Suffield Research Centre, P.O. Box 4000, Station Main, Medicine Hat, Alberta T1A 8K6, Canada
| | - Heinz-Bernhard Kraatz
- Department
of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario M1C 1A4, Canada
- Department
of Chemistry, University of Toronto, 80 Saint George Street, Toronto, Ontario M5S 3H6, Canada
- Department
of Chemistry and Chemical Engineering, Royal Military College of Canada, P.O. Box
17000, Station Forces, Kingston, Ontario K7K 7B4, Canada
| |
Collapse
|
13
|
Labib M, Khan N, Berezovski MV. Protein electrocatalysis for direct sensing of circulating microRNAs. Anal Chem 2014; 87:1395-403. [PMID: 25495265 DOI: 10.1021/ac504331c] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
MicroRNAs (miRNAs) are potentially useful biomarkers for diagnosis, classification, and prognosis of many diseases, including cancer. Herein, we developed a protein-facilitated electrocatalytic quadroprobe sensor (Sens(PEQ)) for detection of miRNA signature of chronic lymphocytic leukemia (CLL) in human serum. The developed signal-ON sensor provides a compatible combination of two DNA adaptor strands modified with four methylene blue molecules and electrocatalysis using glucose oxidase in order to enhance the overall signal gain. This enhanced sensitivity provided the response necessary to detect the low-abundant serum miRNAs without preamplification. The developed Sens(PEQ) is exquisitely sensitive to subtle π-stack perturbations and capable of distinguishing single base mismatches in the target miRNA. Furthermore, the developed sensor was employed for profiling of three endogenous miRNAs characteristic to CLL, including hsa-miR-16-5p, hsa-miR-21-5p, and hsa-miR-150-5p in normal healthy serum, chronic lymphocytic leukemia Rai stage 1 (CLL-1), and stage 3 (CLL-3) sera, using a non-human cel-miR-39-3p as an internal standard. The sensor results were verified by conventional SYBR green-based quantitative reverse-transcription polymerase chain reaction (RT-qPCR) analysis.
Collapse
Affiliation(s)
- Mahmoud Labib
- Department of Chemistry, University of Ottawa , 10 Marie Curie, Ottawa, Ontario K1N 6N5, Canada
| | | | | |
Collapse
|
14
|
Electrochemical sensing of microRNAs: avenues and paradigms. Biosens Bioelectron 2014; 68:83-94. [PMID: 25562735 DOI: 10.1016/j.bios.2014.12.026] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2014] [Revised: 11/24/2014] [Accepted: 12/09/2014] [Indexed: 01/24/2023]
Abstract
Twenty years has passed since the first discovery of microRNA (miRNA) lin-4 in Caenorhabditis elegans. Over the last two decades, the study of miRNAs has attracted tremendous attention. These new stars of biomarkers are naturally occurring non-coding RNAs that regulate gene expression posttranscriptionally and have been demonstrated to be dysregulated in many diseases. Since their profiles reflect pathological conditions, miRNAs have recently been proposed as biomarkers of the onset, prognosis and risk of diseases, as well as in the classification of different types of cancer. The establishment of miRNA profiles for diseases and the detection of different types and levels of miRNAs in biological samples are therefore critical milestones in diagnostics. This provides powerful impetus and a growing demand for researchers to develop simple analytical techniques to allow for an accurate, sensitive, selective, and cost effective miRNA analysis at point-of-care settings. Among several methods proposed for miRNA detection, electrochemical nucleic acid biosensors exhibit many attractive features and could play a leading role in future miRNA detection and quantification. This review gives an overview of recent advances in the rapidly growing area of electrochemical detection of miRNAs. The fundamentals of the different strategies adopted for miRNA detection are discussed and some examples of relevant approaches are highlighted, along with future prospects and challenges.
Collapse
|
15
|
Wehbe M, Labib M, Muharemagic D, Zamay AS, Berezovski MV. Switchable aptamers for biosensing and bioseparation of viruses (SwAps-V). Biosens Bioelectron 2014; 67:280-6. [PMID: 25190090 DOI: 10.1016/j.bios.2014.08.033] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2014] [Revised: 08/08/2014] [Accepted: 08/18/2014] [Indexed: 11/29/2022]
Abstract
There is a widespread interest in the development of aptamer-based affinity chromatographic methods for purification of biomolecules. Regardless of the many advantages exhibited by aptamers when compared to other recognition elements, the lack of an efficient regeneration technique that can be generalized to all targets has encumbered further integration of aptamers into affinity-based purification methods. Here we offer switchable aptamers (SwAps) that have been developed to solve this problem and move aptamer-based chromatography forward. SwAps are controlled-affinity aptamers, which have been employed here to purify vesicular stomatitis virus (VSV) as a model case, however this technique can be extended to all biologically significant molecules. VSV is one oncolytic virus out of an arsenal of potential candidates shown to provide selective destruction of cancer cells both in vitro and in vivo. These SwAps were developed in the presence of Ca(2+) and Mg(2+) ions where they cannot bind to their target VSV in absence of these cations. Upon addition of EDTA and EGTA, the divalent cations were sequestered from the stabilized aptameric structure causing a conformational change and subsequently release of the virus. Both flow cytometry and electrochemical impedance spectroscopy were employed to estimate the binding affinities between the selected SwAps and VSV and to determine the coefficient of switching (CoS) upon elution. Among fifteen sequenced SwAps, four have exhibited high affinity to VSV and ability to switch upon elution and thus were further integrated into streptavidin-coated magnetic beads for purification of VSV.
Collapse
Affiliation(s)
- Mohamed Wehbe
- Department of Chemistry, University of Ottawa, Ottawa, Ontario, Canada
| | - Mahmoud Labib
- Department of Chemistry, University of Ottawa, Ottawa, Ontario, Canada
| | | | - Anna S Zamay
- Department of Chemistry, University of Ottawa, Ottawa, Ontario, Canada; Institute of Chemistry and Chemical Technology SB RAS, 50 Akademgorodok, Krasnoyarsk 660036, Russia
| | | |
Collapse
|
16
|
Suaifan GARY, Shehadeh M, Al-Ijel H, Ng A, Zourob M. Recent progress in prostate-specific antigen and HIV proteases detection. Expert Rev Mol Diagn 2014; 13:707-18. [PMID: 24063398 DOI: 10.1586/14737159.2013.835576] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Proteases mediate a wide variety of biological events and have a critical role in the development of many diseases. Protease detection methods can be hindered by the limitation of assay safety, sensitivity, specificity, time constraints and ease of on-site analysis. Notably, the implementation of various detection methods on biosensing platforms translates them into practical biosensing applications. Currently, the detection of prostate cancer and AIDS at the earliest occasion is one of the major research obstacles. Therefore, recent advances focus on the development of portable detection systems toward point-of-care testing. These detection systems should be highly sensitive and specific for the detection of their prognostic biomarkers, such as the prostate-specific antigen and HIV load assay for prostate cancer and AIDS, respectively. These methods will also facilitate decision-making on a treatment regimen.
Collapse
Affiliation(s)
- Ghadeer A R Y Suaifan
- Department of Pharmaceutical Sciences, Faculty of Pharmacy, The University of Jordan, Amman 11942, Jordan
| | | | | | | | | |
Collapse
|
17
|
Li Y, Afrasiabi R, Fathi F, Wang N, Xiang C, Love R, She Z, Kraatz HB. Impedance based detection of pathogenic E. coli O157:H7 using a ferrocene-antimicrobial peptide modified biosensor. Biosens Bioelectron 2014; 58:193-9. [PMID: 24637168 DOI: 10.1016/j.bios.2014.02.045] [Citation(s) in RCA: 96] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2013] [Revised: 02/14/2014] [Accepted: 02/17/2014] [Indexed: 01/20/2023]
Abstract
Escherichia coli O157:H7 can cause life-threatening gastrointestinal diseases and has been a severe public health problem worldwide in recent years. A novel biosensor for the detection of E. coli O157:H7 is described here using a film composed of ferrocene-peptide conjugates, in which the antimicrobial peptide magainin I has been incorporated as the biorecognition element. Electrochemical impedance spectroscopy was employed to investigate the surface characteristics of the newly developed biosensor and to monitor the interactions between the peptide film and the pathogenic bacteria. X-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectrometry (ToF-SIMS) were employed to confirm the immobilization of ferrocene-conjugate onto the gold surface. Non-pathogenic E. coli K12, Staphylococcus epidermidis and Bacillus subtilis were used in this study to evaluate the selectivity of the proposed biosensor. The results have shown the order of the preferential selectivity of the method is E. coli O157:H7>non-pathogenic E. coli>gram positive species. The detection of E. coli O157:H7 with a sensitivity of 10(3)cfu/mL is enabled by the biosensor. The experimental conditions have been optimized and the plot of changes of charge transfer resistance (ΔRCT) and the logarithm of the cell concentration of E. coli O157:H7 shows a linear correlation in the range of 10(3)-10(7)cfu/mL with a correlation coefficient of 0.983.
Collapse
Affiliation(s)
- Yongxin Li
- Department of Sanitary Chemistry, Public Health School, West China Medical Center, Sichuan University, Chengdu 610044, PR China; Department of Physical and Environmental Sciences, University of Toronto Scarborough, Toronto M1C 1A4, Canada
| | - Rouzbeh Afrasiabi
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, Toronto M1C 1A4, Canada
| | - Farkhondeh Fathi
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, Toronto M1C 1A4, Canada
| | - Nan Wang
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, Toronto M1C 1A4, Canada
| | - Cuili Xiang
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, Toronto M1C 1A4, Canada; Department of Material Science and Engineering, Guilin University of Electronic Technology, Guilin 541004, PR China
| | - Ryan Love
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, Toronto M1C 1A4, Canada
| | - Zhe She
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, Toronto M1C 1A4, Canada
| | - Heinz-Bernhard Kraatz
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, Toronto M1C 1A4, Canada.
| |
Collapse
|
18
|
Giamberardino A, Labib M, Hassan EM, Tetro JA, Springthorpe S, Sattar SA, Berezovski MV, DeRosa MC. Ultrasensitive norovirus detection using DNA aptasensor technology. PLoS One 2013; 8:e79087. [PMID: 24244426 PMCID: PMC3828344 DOI: 10.1371/journal.pone.0079087] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2013] [Accepted: 09/26/2013] [Indexed: 12/31/2022] Open
Abstract
DNA aptamers were developed against murine norovirus (MNV) using SELEX (Systematic Evolution of Ligands by EXponential enrichment). Nine rounds of SELEX led to the discovery of AG3, a promising aptamer with very high affinity for MNV as well as for lab-synthesized capsids of a common human norovirus (HuNoV) outbreak strain (GII.3). Using fluorescence anisotropy, AG3 was found to bind with MNV with affinity in the low picomolar range. The aptamer could cross-react with HuNoV though it was selected against MNV. As compared to a non-specific DNA control sequence, the norovirus-binding affinity of AG3 was about a million-fold higher. In further tests, the aptamer also showed nearly a million-fold higher affinity for the noroviruses than for the feline calicivirus (FCV), a virus similar in size and structure to noroviruses. AG3 was incorporated into a simple electrochemical sensor using a gold nanoparticle-modified screen-printed carbon electrode (GNPs-SPCE). The aptasensor could detect MNV with a limit of detection of approximately 180 virus particles, for possible on-site applications. The lead aptamer candidate and the aptasensor platform show promise for the rapid detection and identification of noroviruses in environmental and clinical samples.
Collapse
Affiliation(s)
- Amanda Giamberardino
- Department of Chemistry, Carleton University, Steacie Building, Ottawa, Ontario, Canada
| | - Mahmoud Labib
- Department of Chemistry, University of Ottawa, Ottawa, Ontario, Canada
| | - Eman M. Hassan
- Department of Chemistry, Carleton University, Steacie Building, Ottawa, Ontario, Canada
| | - Jason A. Tetro
- Centre for Research on Environmental Microbiology, University of Ottawa, Ottawa, Ontario, Canada
| | - Susan Springthorpe
- Centre for Research on Environmental Microbiology, University of Ottawa, Ottawa, Ontario, Canada
| | - Syed A. Sattar
- Centre for Research on Environmental Microbiology, University of Ottawa, Ottawa, Ontario, Canada
| | | | - Maria C. DeRosa
- Department of Chemistry, Carleton University, Steacie Building, Ottawa, Ontario, Canada
| |
Collapse
|
19
|
Zhang XY, Zhou LY, Luo HQ, Li NB. A sensitive and label-free impedimetric biosensor based on an adjunct probe. Anal Chim Acta 2013; 776:11-6. [DOI: 10.1016/j.aca.2013.03.030] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2012] [Revised: 03/04/2013] [Accepted: 03/12/2013] [Indexed: 11/27/2022]
|
20
|
Labib M, Khan N, Ghobadloo SM, Cheng J, Pezacki JP, Berezovski MV. Three-mode electrochemical sensing of ultralow microRNA levels. J Am Chem Soc 2013; 135:3027-38. [PMID: 23362834 DOI: 10.1021/ja308216z] [Citation(s) in RCA: 178] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
MicroRNAs (miRNAs) are an emerging class of biomarkers that are frequently deregulated in cancer cells and have shown great promise for cancer classification and prognosis. In this work, we developed a three-mode electrochemical sensor for detection and quantitation of ultralow levels of miRNAs in a wide dynamic range of measured concentrations. The sensor facilitates three detection modalities based on hybridization (H-SENS), p19 protein binding (P-SENS), and protein displacement (D-SENS). The combined three-mode sensor (HPD-SENS) identifies as low as 5 aM or 90 molecules of miRNA per 30 μL of sample without PCR amplification, and can be operated within the dynamic range from 10 aM to 1 μM. The HPD sensor is made on a commercially available gold nanoparticles-modified electrode and is suitable for analyzing multiple miRNAs on a single electrode. This three-mode sensor exhibits high selectivity and specificity and was used for sequential analysis of miR-32 and miR-122 on one electrode. In addition, the H-SENS can recognize miRNAs with different A/U and G/C content and distinguish between a fully matched miRNA and a miRNA comprising either a terminal or a middle single base mutation. Furthermore, the H- and P-SENS were successfully employed for direct detection and profiling of three endogenous miRNAs, including hsa-miR-21, hsa-miR-32, and hsa-miR-122 in human serum, and the sensor results were validated by qPCR.
Collapse
Affiliation(s)
- Mahmoud Labib
- Department of Chemistry, University of Ottawa, 10 Marie Curie, Ottawa, Ontario K1N 6N5, Canada
| | | | | | | | | | | |
Collapse
|
21
|
Labib M, Zamay AS, Berezovski MV. Multifunctional electrochemical aptasensor for aptamer clones screening, virus quantitation in blood and viability assessment. Analyst 2013; 138:1865-75. [PMID: 23381386 DOI: 10.1039/c3an36771a] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A novel attempt was made to develop a disposable multifunctional sensor for analysis of vaccinia virus (VACV), a promising oncolytic agent that can replicate in and kill tumor cells. Briefly, we developed aptamers specific to VACV that were negatively selected against human serum as well as human and mouse blood to be further utilized for viral analysis directly in serum and blood. In addition, the aptamers were negatively selected against heat-inactivated VACV to enable them to distinguish between viable and nonviable virus particles. The selected aptamers were integrated onto an electrochemical aptasensor to perform multiple functions, including quantification of VACV, viability assessment of the virus, and estimation of the binding affinity between the virus and the developed aptamers. The aptasensor was fabricated by self-assembling a hybrid of a thiolated ssDNA primer and a VACV-specific aptamer onto a gold nanoparticles modified screen-printed carbon electrode (GNPs-SPCE). Square wave voltammetry was employed to quantify VACV in serum and blood within the range of 150-900 PFU, with a detection limit of 60 PFU in 30 μL. According to the electrochemical affinity measurements, three virus specific aptamer clones, V-2, V-5, and V-9 exhibited the highest affinity to VACV. Furthermore, flow cytometry was employed to estimate the dissociation constants of the clones which were found to be 26.3, 40.9, and 24.7 nM, respectively. Finally, the developed aptasensor was able to distinguish between the intact virus and the heat-inactivated virus thanks to the tailored selectivity of the aptamers that was achieved via negative selection.
Collapse
Affiliation(s)
- Mahmoud Labib
- Department of Chemistry, University of Ottawa, 10 Marie Curie, Ottawa, Ontario K1N 6N5, Canada
| | | | | |
Collapse
|
22
|
Labib M, Berezovski MV. Electrochemical aptasensors for microbial and viral pathogens. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2013; 140:155-81. [PMID: 23917779 DOI: 10.1007/10_2013_229] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Aptamers are DNA and RNA oligonucleotides that can bind to a variety of nonnucleic acid targets with high affinity and specificity. Pathogen detection is a promising area in aptamer research. One of its major advantages is the ability of the aptamers to target and specifically differentiate microbial and viral strains without previous knowledge of the membrane-associated antigenic determinants or molecular biomarkers present in that particular microorganism. Electrochemical sensors emerged as a promising field in the area of aptamer research and pathogen detection. An electrochemical sensor is a device that combines a recognition element and an electrochemical transduction unit, where aptamers represent the latest addition to the large catalog of recognition elements. This chapter summarizes and evaluates recent developments of electrochemical aptamer-based sensors for microbial and viral pathogen detection, viability assessment of microorganisms, bacterial typing, identification of epitope-specific aptamers, affinity measurement between aptamers and their respective targets, and estimation of the degree of aptamer protection of oncolytic viruses for therapeutic purposes.
Collapse
Affiliation(s)
- Mahmoud Labib
- Department of Chemistry, University of Ottawa, 10 Marie Curie, Ottawa, ON K1N 6N5, Canada
| | | |
Collapse
|
23
|
Labib M, Zamay AS, Kolovskaya OS, Reshetneva IT, Zamay GS, Kibbee RJ, Sattar SA, Zamay TN, Berezovski MV. Aptamer-based viability impedimetric sensor for bacteria. Anal Chem 2012; 84:8966-9. [PMID: 23075417 DOI: 10.1021/ac302902s] [Citation(s) in RCA: 96] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
The development of an aptamer-based viability impedimetric sensor for bacteria (AptaVISens-B) is presented. Highly specific DNA aptamers to live Salmonella typhimurium were selected via the cell-systematic evolution of ligands by exponential enrichment (SELEX) technique. Twelve rounds of selection were performed; each comprises a positive selection step against viable S. typhimurium and a negative selection step against heat killed S. typhimurium and a mixture of related pathogens, including Salmonella enteritidis, Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa, and Citrobacter freundii to ensure the species specificity of the selected aptamers. The DNA sequence showing the highest binding affinity to the bacteria was further integrated into an impedimetric sensor via self-assembly onto a gold nanoparticle-modified screen-printed carbon electrode (GNP-SPCE). Remarkably, this aptasensor is highly selective and can successfully detect S. typhimurium down to 600 CFU mL(-1) (equivalent to 18 live cells in 30 μL of assay volume) and distinguish it from other Salmonella species, including S. enteritidis and S. choleraesuis. This report is envisaged to open a new venue for the aptamer-based viability sensing of a variety of microorganisms, particularly viable but nonculturable (VBNC) bacteria, using a rapid, economic, and label-free electrochemical platform.
Collapse
|
24
|
Labib M, Zamay AS, Kolovskaya OS, Reshetneva IT, Zamay GS, Kibbee RJ, Sattar SA, Zamay TN, Berezovski MV. Aptamer-based impedimetric sensor for bacterial typing. Anal Chem 2012; 84:8114-7. [PMID: 22971146 DOI: 10.1021/ac302217u] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
The development of an aptamer-based impedimetric sensor for typing of bacteria (AIST-B) is presented. Highly specific DNA aptamers to Salmonella enteritidis were selected via Cell-SELEX technique. Twelve rounds of selection were performed; each comprises a positive selection step against S. enteritidis and a negative selection step against a mixture of related pathogens, including Salmonella typhimurium, Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa, and Citrobacter freundii, to ensure the species-specificity of the selected aptamers. After sequencing of the pool showing the highest binding affinity to S. enteritidis, a DNA sequence of high affinity to the bacteria was integrated into an impedimetric sensor via self-assembly onto a gold nanoparticles-modified screen-printed carbon electrode (GNPs-SPCE). Remarkably, this aptasensor is highly selective and can successfully detect S. enteritidis down to 600 CFU mL(-1) (equivalent to 18 CFU in 30 μL assay volume) in 10 min and distinguish it from other Salmonella species, including S. typhimurium and S. choleraesuis. This report is envisaged to open a new venue for the aptamer-based typing of a variety of microorganisms using a rapid, economic, and label-free electrochemical platform.
Collapse
Affiliation(s)
- Mahmoud Labib
- Department of Chemistry, University of Ottawa, 10 Marie Curie, Ottawa, Ontario K1N 6N5, Canada
| | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Martić S, Gabriel M, Turowec JP, Litchfield DW, Kraatz HB. Versatile Strategy for Biochemical, Electrochemical and Immunoarray Detection of Protein Phosphorylations. J Am Chem Soc 2012; 134:17036-45. [DOI: 10.1021/ja302586q] [Citation(s) in RCA: 67] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Sanela Martić
- Department of Physical and Environmental
Sciences, University of Toronto Scarborough, Toronto, Ontario M1C 1A4, Canada, and Department of Chemistry, University of Toronto, Toronto, Ontario M5S 3H6, Canada
| | - Michelle Gabriel
- Department of Biochemistry,
Schulich School of Medicine and Dentistry, Western University, London, Ontario N6A 5C1, Canada
| | - Jacob P. Turowec
- Department of Biochemistry,
Schulich School of Medicine and Dentistry, Western University, London, Ontario N6A 5C1, Canada
| | - David W. Litchfield
- Department of Biochemistry,
Schulich School of Medicine and Dentistry, Western University, London, Ontario N6A 5C1, Canada
| | - Heinz-Bernhard Kraatz
- Department of Physical and Environmental
Sciences, University of Toronto Scarborough, Toronto, Ontario M1C 1A4, Canada, and Department of Chemistry, University of Toronto, Toronto, Ontario M5S 3H6, Canada
| |
Collapse
|
26
|
Labib M, Zamay AS, Muharemagic D, Chechik AV, Bell JC, Berezovski MV. Electrochemical differentiation of epitope-specific aptamers. Anal Chem 2012; 84:2548-56. [PMID: 22324738 DOI: 10.1021/ac300047c] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
DNA aptamers are promising immunoshielding agents that could protect oncolytic viruses (OVs) from neutralizing antibodies (nAbs) and increase the efficiency of cancer treatment. In the present Article, we introduce a novel technology for electrochemical differentiation of epitope-specific aptamers (eDEA) without selecting aptamers against individual antigenic determinants. For this purpose, we selected DNA aptamers that can bind noncovalently to an intact oncolytic virus, vaccinia virus (VACV), which can selectively replicate in and kill only tumor cells. The aptamers were integrated as a recognition element into a multifunctional electrochemical aptasensor. The developed aptasensor was used for the linear quantification of the virus in the range of 500-3000 virus particles with a detection limit of 330 virions. Also, the aptasensor was employed to compare the binding affinities of aptamers to VACV and to estimate the degree of protection of VACV using the anti-L1R neutralizing antibody in a displacement assay fashion. Three anti-VACV aptamer clones, vac2, vac4, and vac6, showed the best immunoprotection results and can be applied for enhanced delivery of VACV. Another two sequences, vac5 and vac46, exhibited high affinities to VACV without shielding it from nAb and can be further utilized in sandwich bioassays.
Collapse
Affiliation(s)
- Mahmoud Labib
- Department of Chemistry, University of Ottawa, 10 Marie Curie, Ottawa, Ontario K1N 6N5, Canada
| | | | | | | | | | | |
Collapse
|
27
|
Labib M, Zamay AS, Muharemagic D, Chechik AV, Bell JC, Berezovski MV. Aptamer-based viability impedimetric sensor for viruses. Anal Chem 2012; 84:1813-6. [PMID: 22303883 DOI: 10.1021/ac203412m] [Citation(s) in RCA: 76] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The development of aptamer-based viability impedimetric sensor for viruses (AptaVISens-V) is presented. Highly specific DNA aptamers to intact vaccinia virus were selected using cell-SELEX technique and integrated into impedimetric sensors via self-assembly onto a gold microelectrode. Remarkably, this aptasensor is highly selective and can successfully detect viable vaccinia virus particles (down to 60 virions in a microliter) and distinguish them from nonviable viruses in a label-free electrochemical assay format. It also opens a new venue for the development of a variety of viability sensors for detection of many microorganisms and spores.
Collapse
Affiliation(s)
- Mahmoud Labib
- Department of Chemistry, University of Ottawa, 10 Marie Curie, Ottawa, Ontario K1N 6N5, Canada
| | | | | | | | | | | |
Collapse
|
28
|
Labib M, Zamay AS, Muharemagic D, Chechik A, Bell JC, Berezovski MV. Electrochemical sensing of aptamer-facilitated virus immunoshielding. Anal Chem 2012; 84:1677-86. [PMID: 22242920 DOI: 10.1021/ac202978r] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Oncolytic viruses (OVs) are promising therapeutics that selectively replicate in and kill tumor cells. However, repetitive administration of OVs provokes the generation of neutralizing antibodies (nAbs) that can diminish their anticancer effects. In this work, we selected DNA aptamers against an oncolytic virus, vesicular stomatitis virus (VSV), to protect it from nAbs. A label-free electrochemical aptasensor was used to evaluate the degree of protection (DoP). The aptasensor was fabricated by self-assembling a hybrid of a thiolated ssDNA primer and a VSV-specific aptamer. Electrochemical impedance spectroscopy was employed to quantitate VSV in the range of 800-2200 PFU and a detection limit of 600 PFU. The aptasensor was also utilized for evaluating binding affinities between VSV and aptamer pools/clones. An electrochemical displacement assay was performed in the presence of nAbs and DoP values were calculated for several VSV-aptamer pools/clones. A parallel flow cytometric analysis confirmed the electrochemical results. Finally, four VSV-specific aptamer clones, ZMYK-20, ZMYK-22, ZMYK-23, and ZMYK-28, showed the highest protective properties with dissociation constants of 17, 8, 20, and 13 nM, respectively. Another four sequences, ZMYK-1, -21, -25, and -29, exhibited high affinities to VSV without protecting it from nAbs and can be further utilized in sandwich assays. Thus, ZMYK-22, -23, and -28 have the potential to allow efficient delivery of VSV through the bloodstream without compromising the patient's immune system.
Collapse
Affiliation(s)
- Mahmoud Labib
- Department of Chemistry, University of Ottawa, 10 Marie Curie, Ottawa, Ontario K1N 6N5, Canada
| | | | | | | | | | | |
Collapse
|
29
|
Long YM, Zhao QL, Zhang ZL, Tian ZQ, Pang DW. Electrochemical methods – important means for fabrication of fluorescent nanoparticles. Analyst 2012; 137:805-15. [DOI: 10.1039/c2an15740c] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
30
|
Sowole MA, Kraatz HB. Electrochemical detection of hepatitis C viral NS3-4A protease. Analyst 2012; 137:1120-4. [DOI: 10.1039/c2an15881g] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
31
|
Huy TQ, Hanh NTH, Thuy NT, Chung PV, Nga PT, Tuan MA. A novel biosensor based on serum antibody immobilization for rapid detection of viral antigens. Talanta 2011; 86:271-7. [PMID: 22063541 PMCID: PMC7111752 DOI: 10.1016/j.talanta.2011.09.012] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2011] [Revised: 09/09/2011] [Accepted: 09/09/2011] [Indexed: 11/18/2022]
Abstract
In this paper, we represent a label-free biosensor based on immobilization of serum antibodies for rapid detection of viral antigens. Human serum containing specific antibodies against Japanese encephalitis virus (JEV) was immobilized on a silanized surface of an interdigitated sensor via protein A/glutaraldehyde for electrical detection of JEV antigens. The effective immobilization of serum antibodies on the sensor surface was verified by Fourier transform infrared spectrometry and fluorescence microscopy. The signal of the biosensor obtained by the differential voltage converted from the change into non-Faradic impedance resulting from the specific binding of JEV antigens on the surface of the sensor. The detection analyzed indicates that the detection range of this biosensor is 1-10 μg/ml JEV antigens, with a detection limit of 0.75 μg/ml and that stable signals are measured in about 20 min. This study presents a useful biosensor with a high selectivity for rapid and simple detection of JEV antigens, and it also proposes the biosensor as a future diagnostic tool for rapid and direct detection of viral antigens in clinical samples for preliminary pathogenic screenings in the case of possible outbreaks.
Collapse
Affiliation(s)
- Tran Quang Huy
- National Institute of Hygiene and Epidemiology (NIHE), 1 Yersin Street, Hanoi, Viet Nam.
| | | | | | | | | | | |
Collapse
|
32
|
Martić S, Labib M, Kraatz HB. On chip electrochemical detection of sarcoma protein kinase and HIV-1 reverse transcriptase. Talanta 2011; 85:2430-6. [DOI: 10.1016/j.talanta.2011.07.090] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2011] [Accepted: 07/26/2011] [Indexed: 11/24/2022]
|
33
|
Electrochemical analysis of HIV-1 reverse transcriptase serum level: Exploiting protein binding to a functionalized nanostructured surface. Talanta 2011; 85:770-8. [DOI: 10.1016/j.talanta.2011.04.070] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2011] [Revised: 04/26/2011] [Accepted: 04/27/2011] [Indexed: 11/21/2022]
|
34
|
A bioorganometallic approach for rapid electrochemical analysis of human immunodeficiency virus type-1 reverse transcriptase in serum. Electrochim Acta 2011. [DOI: 10.1016/j.electacta.2011.03.063] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
35
|
Gerasimov JY, Lai RY. Design and characterization of an electrochemical peptide-based sensor fabricated via“click” chemistry. Chem Commun (Camb) 2011; 47:8688-90. [DOI: 10.1039/c1cc12783g] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|