1
|
Needs SH, Sirivisoot S, Jegouic S, Prommool T, Luangaram P, Srisawat C, Sriraksa K, Limpitikul W, Mairiang D, Malasit P, Avirutnan P, Puttikhunt C, Edwards AD. Smartphone multiplex microcapillary diagnostics using Cygnus: Development and evaluation of rapid serotype-specific NS1 detection with dengue patient samples. PLoS Negl Trop Dis 2022; 16:e0010266. [PMID: 35389998 PMCID: PMC8989202 DOI: 10.1371/journal.pntd.0010266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Accepted: 02/18/2022] [Indexed: 11/18/2022] Open
Abstract
Laboratory diagnosis of dengue virus (DENV) infection including DENV serotyping requires skilled labor and well-equipped settings. DENV NS1 lateral flow rapid test (LFT) provides simplicity but lacks ability to identify serotype. A simple, economical, point-of-care device for serotyping is still needed. We present a gravity driven, smartphone compatible, microfluidic device using microcapillary film (MCF) to perform multiplex serotype-specific immunoassay detection of dengue virus NS1. A novel device–termed Cygnus–with a stackable design allows analysis of 1 to 12 samples in parallel in 40 minutes. A sandwich enzyme immunoassay was developed to specifically detect NS1 of all four DENV serotypes in one 60-μl plasma sample. This test aims to bridge the gap between rapid LFT and laboratory microplate ELISAs in terms of sensitivity, usability, accessibility and speed. The Cygnus NS1 assay was evaluated with retrospective undiluted plasma samples from 205 DENV infected patients alongside 50 febrile illness negative controls. Against the gold standard RT-PCR, clinical sensitivity for Cygnus was 82% in overall (with 78, 78, 80 and 76% for DENV1-4, respectively), comparable to an in-house serotyping NS1 microplate ELISA (82% vs 83%) but superior to commercial NS1-LFT (82% vs 74%). Specificity of the Cygnus device was 86%, lower than that of NS1-microplate ELISA and NS1-LFT (100% and 98%, respectively). For Cygnus positive samples, identification of DENV serotypes DENV2-4 matched those by RT-PCR by 100%, but for DENV1 capillaries false positives were seen, suggesting an improved DENV1 capture antibody is needed to increase specificity. Overall performance of Cygnus showed substantial agreement to NS1-microplate ELISA (κ = 0.68, 95%CI 0.58–0.77) and NS1-LFT (κ = 0.71, 95%CI 0.63–0.80). Although further refinement for DENV-1 NS1 detection is needed, the advantages of multiplexing and rapid processing time, this Cygnus device could deliver point-of-care NS1 antigen testing including serotyping for timely DENV diagnosis for epidemic surveillance and outbreak prediction. Diagnosis of the important mosquito-transmitted dengue virus (DENV) requires laboratory assays to detect viral genome (RT-PCR), viral NS1 protein (immunoassay) or DENV specific antibodies. Current point-of-care NS1 tests cannot distinguish serotype, so laboratory tests are still essential to determine which of 4 DENV serotypes is present. Here we present a rapid serotype-specific NS1 test in a portable microfluidic format. Ten parallel 0.2 mm tubes inside a flat plastic ribbon perform multiplex NS1 immunoassays. A simple cassette delivers sample and reagents sequentially through the microcapillaries by gravity. By stacking cassettes, 12 tests could be performed in under 40 minutes, with results recorded by smartphone. When evaluated with 205 patients plus 50 control samples, and results compared to conventional RT-PCR, the sensitivity for DENV1 to 4 was 78%, 78%, 80%, and 76%, respectively, with specificity of 100% for DENV2-4. DENV1 showed some false positives due to cross-reactivity of the capture antibody. Serotyping performance with MCF-Cygnus devices showed substantial agreement to the serotyping-NS1 microplate ELISA. Therefore, these simple and portable microcapillary immunoassay devices could support dengue NS1 serotyping with potential benefits for near-patient diagnosis, real-time epidemic surveillance and outbreak mapping.
Collapse
Affiliation(s)
- Sarah Helen Needs
- Reading School of Pharmacy, University of Reading, Whiteknights, Reading, United Kingdom
| | - Sirintra Sirivisoot
- Division of Dengue Hemorrhagic Fever Research, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Sophie Jegouic
- Reading School of Pharmacy, University of Reading, Whiteknights, Reading, United Kingdom
| | - Tanapan Prommool
- Molecular Biology of Dengue and Flaviviruses Research Team, Medical Molecular Biotechnology Research Group, National Center for Genetic Engineering and Biotechnology, National Science and Technology Development Agency, Pathum Thani, Thailand
| | - Prasit Luangaram
- Molecular Biology of Dengue and Flaviviruses Research Team, Medical Molecular Biotechnology Research Group, National Center for Genetic Engineering and Biotechnology, National Science and Technology Development Agency, Pathum Thani, Thailand
| | - Chatchawan Srisawat
- Department of Biochemistry, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Kanokwan Sriraksa
- Pediatric Department, Khon Kaen Hospital, Ministry of Health, Khon Kaen, Thailand
| | - Wannee Limpitikul
- Pediatric Department, Songkhla Hospital, Ministry of Health, Songkhla, Thailand
| | - Dumrong Mairiang
- Division of Dengue Hemorrhagic Fever Research, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
- Molecular Biology of Dengue and Flaviviruses Research Team, Medical Molecular Biotechnology Research Group, National Center for Genetic Engineering and Biotechnology, National Science and Technology Development Agency, Pathum Thani, Thailand
- Siriraj Center of Research Excellence in Dengue and Emerging Pathogens, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Prida Malasit
- Division of Dengue Hemorrhagic Fever Research, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
- Molecular Biology of Dengue and Flaviviruses Research Team, Medical Molecular Biotechnology Research Group, National Center for Genetic Engineering and Biotechnology, National Science and Technology Development Agency, Pathum Thani, Thailand
- Siriraj Center of Research Excellence in Dengue and Emerging Pathogens, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Panisadee Avirutnan
- Division of Dengue Hemorrhagic Fever Research, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
- Molecular Biology of Dengue and Flaviviruses Research Team, Medical Molecular Biotechnology Research Group, National Center for Genetic Engineering and Biotechnology, National Science and Technology Development Agency, Pathum Thani, Thailand
- Siriraj Center of Research Excellence in Dengue and Emerging Pathogens, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
- * E-mail: (PA); (CH); (ADE)
| | - Chunya Puttikhunt
- Division of Dengue Hemorrhagic Fever Research, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
- Molecular Biology of Dengue and Flaviviruses Research Team, Medical Molecular Biotechnology Research Group, National Center for Genetic Engineering and Biotechnology, National Science and Technology Development Agency, Pathum Thani, Thailand
- Siriraj Center of Research Excellence in Dengue and Emerging Pathogens, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
- * E-mail: (PA); (CH); (ADE)
| | - Alexander Daniel Edwards
- Reading School of Pharmacy, University of Reading, Whiteknights, Reading, United Kingdom
- Capillary Film Technology Ltd, Billingshurst, West Sussex, United Kingdom
- * E-mail: (PA); (CH); (ADE)
| |
Collapse
|
2
|
Needs SH, Saiprom N, Rafaque Z, Imtiaz W, Chantratita N, Runcharoen C, Thammachote J, Anun S, Peacock SJ, Ray P, Andrews S, Edwards AD. Miniaturised broth microdilution for simplified antibiotic susceptibility testing of Gram negative clinical isolates using microcapillary devices. Analyst 2022; 147:3558-3569. [DOI: 10.1039/d2an00305h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Miniaturised antibiotic susceptibility testing: 100 times smaller microcapillary broth microdilution gives equivalent result to standard microplate broth microdilution.
Collapse
Affiliation(s)
| | - Natnaree Saiprom
- Department of Microbiology and Immunology, Faculty of Tropical Medicine, Mahidol University, Thailand
| | - Zara Rafaque
- Department of Microbiology, Faculty of Health Sciences, Hazara University, Mansehra, Pakistan
| | - Wajiha Imtiaz
- School of Biological Sciences, University of Reading, RG6 6DX, UK
| | - Narisara Chantratita
- Department of Microbiology and Immunology, Faculty of Tropical Medicine, Mahidol University, Thailand
| | - Chakkaphan Runcharoen
- Department of Microbiology and Immunology, Faculty of Tropical Medicine, Mahidol University, Thailand
| | - Jeeranan Thammachote
- Division of Clinical Microbiology, Medical Technology Department, Bhuddhasothon Hospital, Chachoengsao, Thailand
| | - Suthatip Anun
- Division of Clinical Microbiology, Medical Technology Department, Bhuddhasothon Hospital, Chachoengsao, Thailand
| | | | - Partha Ray
- The Nature Conservancy, Virginia, USA
- School of Agriculture Policy and Development, University of Reading, UK
| | - Simon Andrews
- School of Biological Sciences, University of Reading, RG6 6DX, UK
| | - Alexander D. Edwards
- School of Pharmacy, University of Reading, RG6 6DX, UK
- CFT Ltd, Daux Road, Billingshurst, RH14 9SJ, UK
| |
Collapse
|
3
|
Barbosa AI, Edwards AD, Reis NM. Antibody Surface Coverage Drives Matrix Interference in Microfluidic Capillary Immunoassays. ACS Sens 2021; 6:2682-2690. [PMID: 34138534 PMCID: PMC8741144 DOI: 10.1021/acssensors.1c00704] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Accepted: 06/07/2021] [Indexed: 01/31/2023]
Abstract
The performance of biosensors is often optimized in buffers, which brings inconsistencies during applications with biological samples. Current strategies for minimizing sample (matrix) interference are complex to automate and miniaturize, involving, e.g., sample dilution or recovery of serum/plasma. This study shows the first systematic analysis using hundreds of actual microfluidic immunoassay fluoropolymer strips to understand matrix interference in microflow systems. As many interfering factors are assay-specific, we have explored matrix interference for a range of enzymatic immunoassays, including a direct mIgG/anti-mIgG, a sandwich cancer biomarker PSA, and a sandwich inflammatory cytokine IL-1β. Serum matrix interference was significantly affected by capillary antibody surface coverage, suggesting for the first time that the main cause of the serum matrix effect is low-affinity serum components (e.g., autoantibodies) competing with high-affinity antigens for the immobilized antibody. Additional experiments carried out with different capillary diameters confirmed the importance of antibody surface coverage in managing matrix interference. Building on these findings, we propose a novel analytical approach where antibody surface coverage and sample incubation times are key for eliminating and/or minimizing serum matrix interference, consisting in bioassay optimization carried out in serum instead of buffer, without compromising the performance of the bioassay or adding extra cost or steps. This will help establishing a new route toward faster development of modern point-of-care tests and effective biosensor development.
Collapse
Affiliation(s)
- Ana I. Barbosa
- Department
of Chemical Engineering, Loughborough University, Loughborough LE11 3TU, United Kingdom
- Capillary
Film Technology Ltd, Daux Road, Billingshurst RH14 9SJ, West Sussex, United Kingdom
| | - Alexander D. Edwards
- Capillary
Film Technology Ltd, Daux Road, Billingshurst RH14 9SJ, West Sussex, United Kingdom
- Reading
School of Pharmacy, University of Reading, Whiteknights, Reading RG6 6AD, United
Kingdom
| | - Nuno M. Reis
- Capillary
Film Technology Ltd, Daux Road, Billingshurst RH14 9SJ, West Sussex, United Kingdom
- Department
of Chemical Engineering and Centre for Biosensors, Bioelectronics
and Biodevices (C3Bio), University of Bath, Claverton Down, Bath BA2 7AY, United Kingdom
| |
Collapse
|
4
|
Jégouic SM, Jones IM, Edwards AD. Affordable mobile microfluidic diagnostics: minimum requirements for smartphones and digital imaging for colorimetric and fluorometric anti-dengue and anti-SARS-CoV-2 antibody detection. Wellcome Open Res 2021; 6:57. [PMID: 36312459 PMCID: PMC9614285 DOI: 10.12688/wellcomeopenres.16628.1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/01/2021] [Indexed: 12/23/2022] Open
Abstract
Background: Miniaturised bioassays permit diagnostic testing near the patient, and the results can be recorded digitally using inexpensive cameras including smartphone and mobile phone cameras. Although digital cameras are now inexpensive and portable, the minimum performance required for microfluidic diagnostic bioassays has not been defined. We present a systematic comparison of a wide range of different digital cameras for capturing and measuring results of microfluidic bioassays and describe a framework to specify performance requirements to quantify immunoassays. Methods: A set of 200 µm diameter microchannels was filled with a range of concentrations of dyes used in colorimetric and fluorometric enzyme immunoassays. These were imaged in parallel using cameras of varying cost and performance ranging from <£30 to >£500. Results: Higher resolution imaging allowed larger numbers of microdevices to be resolved and analysed in a single image. In contrast, low quality cameras were still able to quantify results but for fewer samples. In some cases, an additional macro lens was added to focus closely. If image resolution was sufficient to identify individual microfluidic channels as separate lines, all cameras were able to quantify a similar range of concentrations of both colorimetric and fluorometric dyes. However, the mid-range cameras performed better, with the lowest cost cameras only allowing one or two samples to be quantified per image. Consistent with these findings, we demonstrate that quantitation (to determine endpoint titre) of antibodies against dengue and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) viruses is possible using a wide range of digital imaging devices including the mid-range smartphone iPhone 6S and a budget Android smartphone costing <£50. Conclusions: In conclusion, while more expensive and higher quality cameras allow larger numbers of devices to be simultaneously imaged, even the lowest resolution and cheapest cameras were sufficient to record and quantify immunoassay results.
Collapse
Affiliation(s)
- Sophie M. Jégouic
- Reading School of Pharmacy, University of Reading, Reading, RG6 1EE, UK
- School of Biological Sciences, University of Reading, Reading, UK
| | - Ian M. Jones
- School of Biological Sciences, University of Reading, Reading, UK
| | | |
Collapse
|
5
|
Liu J, Xu Z, Shan Y, Huang X. Applications of microcapillary films in bioanalytical techniques. Analyst 2021; 146:1529-1537. [PMID: 33528470 DOI: 10.1039/d0an01945c] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Microcapillary film (MCF) is an extruded plastic film with an array of parallel microcapillaries (30-500 μm) and it has wide potential applications in bioanalytical techniques as a microfluidic platform. With different surface modification strategies, an MCF combines the advantages of its structure and modified chemical properties to realize various bioanalytical functions. In this review, we begin by introducing the manufacturing process of MCFs, common materials used to produce MCFs, surface treatment approaches of inner surfaces, and a signal detection and readout system of the MCF platform. Then, we summarize some typical applications of MCFs, particularly in protein chromatography, Escherichia coli detection for urinary tract infections, prostate-specific antigen detection for prostate cancer and multiplex immunoassays. Finally, future perspectives of MCFs in bioanalytical techniques are discussed.
Collapse
Affiliation(s)
- Junfeng Liu
- Institute of Process Equipment, College of Energy Engineering, Zhejiang University, Hangzhou 310027, China.
| | | | | | | |
Collapse
|
6
|
Alves IP, Reis NM. Microfluidic smartphone quantitation of Escherichia coli in synthetic urine. Biosens Bioelectron 2019; 145:111624. [PMID: 31546201 DOI: 10.1016/j.bios.2019.111624] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Revised: 08/20/2019] [Accepted: 08/21/2019] [Indexed: 10/26/2022]
Abstract
In spite of the clinical need, there is a major gap in rapid diagnostics for identification and quantitation of E. coli and other pathogens, also regarded as the biggest bottleneck in the fight against the spread of antimicrobial resistant bacterial strains. This study reports for the first time an optical, smartphone-based microfluidic fluorescence sandwich immunoassay capable of quantifying E. coli in buffer and synthetic urine in less than 25 min without sample preparation nor concentration. A limit of detection (LoD) up to 240 CFU/mL, comensurate with cut-off for UTIs (103-105 CFUs/mL) was achieved. Replicas of full response curves performed with 100-107 CFUs/mL of E. coli K12 in synthetic urine yielded recovery values in the range 80-120%, assay reproducibility below 30% and precision below 20%, therefore similar to high-performance automated immunoassays. The unrivalled LoD was mainly linked to the 'open fluidics' nature of the 10-bore microfluidic strips used that enabled passing a large volume of sample through the microcapillaries coated with capture antibody. The new smartphone based test has the potential of being as a rapid, point-of-care test for rule-in of E. coli infections that are responsible for around 80% of UTIs, helping to stop the over-prescription of antibiotics and the monitoring of patients with other symptomatic communicable diseases caused by E. coli at global scale.
Collapse
Affiliation(s)
- Isabel P Alves
- Department of Chemical Engineering, Loughborough University, Leicestershire, LE11 3TU, UK
| | - Nuno M Reis
- Centre for Biosensors, Bioelectronics and Biodevices (C3Bio), Department of Chemical Engineering, University of Bath, Bath, BA2 7AY, UK.
| |
Collapse
|
7
|
Barbosa AI, Barreto AS, Reis NM. Transparent, Hydrophobic Fluorinated Ethylene Propylene Offers Rapid, Robust, and Irreversible Passive Adsorption of Diagnostic Antibodies for Sensitive Optical Biosensing. ACS APPLIED BIO MATERIALS 2019; 2:2780-2790. [PMID: 35030812 DOI: 10.1021/acsabm.9b00214] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Current literature data is scarce and somehow contradictory in respect to the suitability of "nonstick" fluoropolymer surfaces for immobilization of biomolecules. We have previously shown empirically that transparent Teflon fluorinated ethylene propylene (FEP) offers rapid and sensitive optical biosensing of clinically relevant biomarkers. This study shows for the first time a comprehensive experimental analysis of passive adsorption of diagnostic IgG antibodies on actual Teflon FEP microfluidic strips. Full equilibrium isotherms and kinetics for passive adsorption were studied and modeled employing a protein titration method using hundreds of multibore microfluidic strips for a range of temperatures, pH, ionic strengths, and inner diameters, using both polyclonal and monoclonal antibody systems. Results were benchmarked against other plastic hydrophobic and glass hydrophilic capillary surfaces. For the first time, it was shown quantitatively that the hydrophobicity of fluoropolymer surfaces encourages the passive adsorption of diagnostic antibodies for biosensing and is insensitive to the temperature of incubation and to ionic buffer strength. The mass of captured antigen increased with increasing antibody surface coverage up to ∼400 ng/cm2, with an optimal adsorbed antibody activity for 45-69% of full monolayer coverage, matching results of other biosensing surfaces. The equilibrium was reached fast, within 5-10 min, and surprisingly both the kinetics and equilibrium of antibody adsorption were dependent on the inner diameter of microcapillaries. This is a novel and relevant result that will generally impact on the design of miniaturized microfluidic biosensing devices. The antibody surface densities obtained with hydrophobic plastic surfaces were 2- to 4-fold lower than for a hydrophilic, glass surface, however the former presented a monolayered adsorption with a higher level of irreversibility, as shown by the adsorption and desorption rates around 1 order of magnitude smaller than for glass, which is highly desirable for biosensing with surface-coated biomolecules.
Collapse
Affiliation(s)
- Ana Isabel Barbosa
- Department of Chemical Engineering, Loughborough University, Loughborough, Leicestershire LE11 3TU, United Kingdom
| | - Augusto Sampaio Barreto
- Department of Chemical Engineering, Loughborough University, Loughborough, Leicestershire LE11 3TU, United Kingdom
| | - Nuno Miguel Reis
- Department of Chemical Engineering, Loughborough University, Loughborough, Leicestershire LE11 3TU, United Kingdom.,Department of Chemical Engineering, University of Bath, Claverton Down, Bath BA2 7AY, United Kingdom
| |
Collapse
|
8
|
Immunocapture of Escherichia coli in a fluoropolymer microcapillary array. J Chromatogr A 2019; 1585:46-55. [DOI: 10.1016/j.chroma.2018.11.067] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Revised: 11/21/2018] [Accepted: 11/24/2018] [Indexed: 11/16/2022]
|
9
|
Pivetal J, Pereira FM, Barbosa AI, Castanheira AP, Reis NM, Edwards AD. Covalent immobilisation of antibodies in Teflon-FEP microfluidic devices for the sensitive quantification of clinically relevant protein biomarkers. Analyst 2018; 142:959-968. [PMID: 28232992 DOI: 10.1039/c6an02622b] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
This study reports for the first time the sensitive colorimetric and fluorescence detection of clinically relevant protein biomarkers by sandwich immunoassays using the covalent immobilisation of antibodies onto the fluoropolymer surface inside Teflon®-FEP microfluidic devices. Teflon®-FEP has outstanding optical transparency ideal for high-sensitivity colorimetric and fluorescence bioassays, however this thermoplastic is regarded as chemically inert and very hydrophobic. Covalent immobilisation can offer benefits over passive adsorption to plastic surfaces by allowing better control over antibody density, orientation and analyte binding capacity, and so we tested a range of different and novel covalent immobilisation strategies. We first functionalised the inner surface of a 10-bore, 200 μm internal diameter FEP microcapillary film with high-molecular weight polyvinyl alcohol (PVOH) without changing the outstanding optical transparency of the device delivered by the matched refractive index of FEP and water. Glutaraldehyde immobilisation was compared with the use of photoactivated linkers and NHS-ester crosslinkers for covalently immobilising capture antibodies onto PVOH. Three clinically relevant sandwich ELISAs were tested against the cytokine IL-1β, the myocardial infarct marker cardiac troponin I (cTnI), and the chronic heart failure marker brain natriuretic peptide (BNP). Overall, glutaraldehyde immobilisation was effective for BNP assays, but yielded unacceptable background for IL-1β and cTnI assays caused by direct binding of the biotinylated detection antibody to the modified PVOH surface. We found NHS-ester groups reacted with APTES-treated PVOH coated fluoropolymers. This facilitated a novel method for capture antibody immobilisation onto fluoropolymer devices using a bifunctional NHS-maleimide crosslinker. The density of covalently immobilised capture antibodies achieved using PVOH/APTES/NHS/maleimide approached levels seen with passive adsorption, and sensitive and quantitative assay performance was achieved using this method. Overall, the PVOH coating provided an excellent surface for controlled covalent antibody immobilisation onto Teflon®-FEP for performing high-sensitivity immunoassays.
Collapse
Affiliation(s)
- Jeremy Pivetal
- Reading School of Pharmacy, University of Reading, Whiteknights, Reading RG6 6AD, UK.
| | - Filipa M Pereira
- Capillary Film Technology Ltd, 2 Daux Road, Billingshurst, RH14 9SJ, UK
| | - Ana I Barbosa
- Capillary Film Technology Ltd, 2 Daux Road, Billingshurst, RH14 9SJ, UK and Department of Chemical Engineering, Loughborough University, Leicestershire, LE11 3TU, UK
| | - Ana P Castanheira
- Capillary Film Technology Ltd, 2 Daux Road, Billingshurst, RH14 9SJ, UK
| | - Nuno M Reis
- Capillary Film Technology Ltd, 2 Daux Road, Billingshurst, RH14 9SJ, UK and Department of Chemical Engineering, Loughborough University, Leicestershire, LE11 3TU, UK and Department of Chemical Engineering, University of Bath, Claverton Down, Bath BA2 7AY, UK.
| | - Alexander D Edwards
- Reading School of Pharmacy, University of Reading, Whiteknights, Reading RG6 6AD, UK. and Capillary Film Technology Ltd, 2 Daux Road, Billingshurst, RH14 9SJ, UK
| |
Collapse
|
10
|
Synergistic Use of Gold Nanoparticles (AuNPs) and "Capillary Enzyme-Linked Immunosorbent Assay (ELISA)" for High Sensitivity and Fast Assays. SENSORS 2017; 18:s18010055. [PMID: 29278402 PMCID: PMC5795359 DOI: 10.3390/s18010055] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2017] [Revised: 12/01/2017] [Accepted: 12/23/2017] [Indexed: 12/12/2022]
Abstract
Using gold nanoparticles (AuNPs) on "capillary enzyme-linked immunosorbent assay (ELISA)", we produced highly sensitive and rapid assays, which are the major attributes for point-of-care applications. First, in order to understand the size effect of AuNPs, AuNPs of varying diameters (5 nm, 10 nm, 15 nm, 20 nm, 30 nm, and 50 nm) conjugated with Horseradish Peroxidase (HRP)-labeled anti-C reactive protein (antiCRP) (AuNP•antiCRP-HRP) were used for well-plate ELISA. AuNP of 10 nm produced the largest optical density, enabling detection of 0.1 ng/mL of CRP with only 30 s of incubation, in contrast to 10 ng/mL for the ELISA run in the absence of AuNP. Then, AuNP of 10 nm conjugated with antiCRP-HRP (AuNP•antiCRP-HRP) was used for "capillary ELISA" to detect as low as 0.1 ng/mL of CRP. Also, kinetic study on both 96-well plates and in a capillary tube using antiCRP-HRP or AuNP•antiCRP-HRP showed a synergistic effect between AuNP and the capillary system, in which the fastest assay was observed from the "AuNP capillary ELISA", with its maximum absorbance reaching 2.5 min, while the slowest was the typical well-plate ELISA with its maximum absorbance reaching in 13.5 min.
Collapse
|
11
|
Towards One-Step Quantitation of Prostate-Specific Antigen (PSA) in Microfluidic Devices: Feasibility of Optical Detection with Nanoparticle Labels. BIONANOSCIENCE 2017; 7:718-726. [PMID: 29214121 PMCID: PMC5698394 DOI: 10.1007/s12668-016-0390-y] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Rapid and quantitative prostate-specific antigen (PSA) biomarker detection would be beneficial to cancer diagnostics, improving early detection and therefore increasing chances of survival. Nanoparticle-based detection is routinely used in one-step nitrocellulose-based lateral flow (LF) immunoassays; however, it is well established within the scientific diagnostic community that LF technology lacks sensitivity for measuring biomarkers, such as prostate-specific antigen (PSA). A trend in point-of-care (POC) protein biomarker quantitation is the miniaturization of immunoassays in microfluidic devices. This work aimed at testing the feasibility of carbon and gold nanoparticles as immunoassay labels for PSA detection with cost-effective optical detection in a novel microfluidic POC platform called microcapillary film (MCF), consisting of a parallel array of fluoropolymer microcapillaries with 200-μm internal diameter. With neutravidin-coated carbon, nanoparticles were able to quantify an immobilized biotinylated monoclonal antibody (coating solution from 10 to 40 μg/ml) and PSA was successfully quantified in a sandwich assay using silver-enhanced gold nanoparticles and a flatbed scanner; yet, the dynamic range was limited to 10–100 ng/ml. Although direct optical detection of PSA without enzymatic amplification or fluorophores is possible and technically appealing for the simplified fluidics and signal scanning setups involved, ultimately, the binding of a thin layer of nanoparticles onto the wall of transparent microcapillaries is not sufficient to cause a significant drop on the optical colorimetric signal. Future studies will explore the use of fluorescence nanoparticles.
Collapse
|
12
|
Reis NM, Pivetal J, Loo-Zazueta AL, Barros JMS, Edwards AD. Lab on a stick: multi-analyte cellular assays in a microfluidic dipstick. LAB ON A CHIP 2016; 16:2891-2899. [PMID: 27374435 DOI: 10.1039/c6lc00332j] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A new microfluidic concept for multi-analyte testing in a dipstick format is presented, termed "Lab-on-a-Stick", that combines the simplicity of dipstick tests with the high performance of microfluidic devices. Lab-on-a-stick tests are ideally suited to analysis of particulate samples such as mammalian or bacterial cells, and capable of performing multiple different parallel microfluidic assays when dipped into a single sample with results recorded optically. The utility of this new diagnostics format was demonstrated by performing three types of multiplex cellular assays that are challenging to perform in conventional dipsticks: 1) instantaneous ABO blood typing; 2) microbial identification; and 3) antibiotic minimum inhibitory (MIC) concentration measurement. A pressure balance model closely predicted the superficial flow velocities in individual capillaries, that were overestimated by up to one order of magnitude by the Lucas-Washburn equation conventionally used for wicking in cylindrical pores. Lab-on-a-stick provides a cost-effective, simple, portable and flexible multiplex platform for a range of assays, and will deliver a new generation of advanced yet affordable point-of-care tests for global diagnostics.
Collapse
Affiliation(s)
- Nuno M Reis
- Department of Chemical Engineering, Loughborough University, Leicestershire, LE11 3TU, UK.
| | | | | | | | | |
Collapse
|
13
|
Klymenko OV, Shah N, Kontoravdi C, Royle KE, Polizzi KM. Designing an Artificial Golgi reactor to achieve targeted glycosylation of monoclonal antibodies. AIChE J 2016. [DOI: 10.1002/aic.15388] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Affiliation(s)
- Oleksiy V. Klymenko
- Dept. of Chemical Engineering, and Centre for Process Systems EngineeringImperial College LondonLondonSW7 2AZ U.K
| | - Nilay Shah
- Dept. of Chemical Engineering, and Centre for Process Systems EngineeringImperial College LondonLondonSW7 2AZ U.K
| | - Cleo Kontoravdi
- Dept. of Chemical Engineering, and Centre for Process Systems EngineeringImperial College LondonLondonSW7 2AZ U.K
| | - Kate E. Royle
- Dept. of Life Sciences and Centre for Synthetic Biology and InnovationImperial College LondonLondonSW7 2AZ U.K
| | - Karen M. Polizzi
- Dept. of Life Sciences and Centre for Synthetic Biology and InnovationImperial College LondonLondonSW7 2AZ U.K
| |
Collapse
|
14
|
Castanheira AP, Barbosa AI, Edwards AD, Reis NM. Multiplexed femtomolar quantitation of human cytokines in a fluoropolymer microcapillary film. Analyst 2016; 140:5609-18. [PMID: 26120601 DOI: 10.1039/c5an00238a] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Sensitive quantitation of multiple cytokines can provide important diagnostic information during infection, inflammation and immunopathology. In this study sensitive immunoassay detection of human cytokines IL-1β, IL-6, IL-12p70 and TNFα is shown for singleplex and multiplex formats using a novel miniaturized ELISA platform. The platform uses a disposable plastic multi-syringe aspirator (MSA) integrating 8 disposable fluoropolymer microfluidic test strips, each containing an array of ten 200 μm mean i.d. microcapillaries coated with a set of monoclonal antibodies. Each MSA device thus performs 10 tests on 8 samples, delivering 80 measurements. Unprecedented levels of sensitivity were obtained with the novel fluoropolymer microfluidic material and simple colorimetric detection in a flatbed scanner. The limit of detection for singleplex detection ranged from 2.0 to 15.0 pg ml(-1), i.e. 35 and 713 femtomolar for singleplex cytokine detection, and the intra- and inter-assay coefficient of variation (CV) remained within 10%. In addition, a triplex immunoassay was developed for measuring IL-1β, IL-12p70 and TNFα simultaneously from a given sample in the pg ml(-1) range. These assays permit high sensitivity measurement with rapid <15 min assay or detection from undiluted blood serum. The portability, speed and low-cost of this system are highly suited to point-of-care testing and field diagnostics applications.
Collapse
Affiliation(s)
- Ana P Castanheira
- Capillary Film Technology Ltd, Billingshurst, West Sussex RH14 9SJ, UK
| | | | | | | |
Collapse
|
15
|
Portable smartphone quantitation of prostate specific antigen (PSA) in a fluoropolymer microfluidic device. Biosens Bioelectron 2015; 70:5-14. [DOI: 10.1016/j.bios.2015.03.006] [Citation(s) in RCA: 179] [Impact Index Per Article: 19.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2015] [Revised: 03/02/2015] [Accepted: 03/03/2015] [Indexed: 11/20/2022]
|
16
|
Medically relevant assays with a simple smartphone and tablet based fluorescence detection system. SENSORS 2015; 15:11653-64. [PMID: 26007723 PMCID: PMC4481933 DOI: 10.3390/s150511653] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Accepted: 05/17/2015] [Indexed: 12/12/2022]
Abstract
Cell phones and smart phones can be reconfigured as biomedical sensor devices but this requires specialized add-ons. In this paper we present a simple cell phone-based portable bioassay platform, which can be used with fluorescent assays in solution. The system consists of a tablet, a polarizer, a smart phone (camera) and a box that provides dark readout conditions. The assay in a well plate is placed on the tablet screen acting as an excitation source. A polarizer on top of the well plate separates excitation light from assay fluorescence emission enabling assay readout with a smartphone camera. The assay result is obtained by analysing the intensity of image pixels in an appropriate colour channel. With this device we carried out two assays, for collagenase and trypsin using fluorescein as the detected fluorophore. The results of collagenase assay with the lowest measured concentration of 3.75 µg/mL and 0.938 µg in total in the sample were comparable to those obtained by a microplate reader. The lowest measured amount of trypsin was 930 pg, which is comparable to the low detection limit of 400 pg for this assay obtained in a microplate reader. The device is sensitive enough to be used in point-of-care medical diagnostics of clinically relevant conditions, including arthritis, cystic fibrosis and acute pancreatitis.
Collapse
|
17
|
Barbosa AI, Castanheira AP, Edwards AD, Reis NM. A lab-in-a-briefcase for rapid prostate specific antigen (PSA) screening from whole blood. LAB ON A CHIP 2014; 14:2918-28. [PMID: 24989886 DOI: 10.1039/c4lc00464g] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
We present a new concept for rapid and fully portable prostate specific antigen (PSA) measurements, termed "lab-in-a-briefcase", which integrates an affordable microfluidic ELISA platform utilising a melt-extruded fluoropolymer microcapillary film (MCF) containing an array of 10 200 μm internal diameter capillaries, a disposable multi-syringe aspirator (MSA), a sample tray pre-loaded with all of the required immunoassay reagents, and a portable film scanner for colorimetric signal digital quantification. Each MSA can perform 10 replicate microfluidic immunoassays on 8 samples, allowing 80 measurements to be made in less than 15 minutes based on semi-automated operation, without the need of additional fluid handling equipment. The assay was optimised for the measurement of a clinically relevant range of PSA of 0.9 to 60.0 ng ml(-1) in 15 minutes with CVs on the order of 5% based on intra-assay variability when read using a consumer flatbed film scanner. The PSA assay performance in the MSA remained robust in undiluted or 1 : 2 diluted human serum or whole blood, and the matrix effect could simply be overcome by extending sample incubation times. The PSA "lab-in-a-briefcase" is particularly suited to a low-resource health setting, where diagnostic labs and automated immunoassay systems are not accessible, by allowing PSA measurement outside the laboratory using affordable equipment.
Collapse
Affiliation(s)
- Ana I Barbosa
- Department of Chemical Engineering, Loughborough University, Loughborough LE11 3TU, UK.
| | | | | | | |
Collapse
|
18
|
Chan AS, Danquah MK, Agyei D, Hartley PG, Zhu Y. A Parametric Study of a Monolithic Microfluidic System for On-Chip Biomolecular Separation. SEP SCI TECHNOL 2014. [DOI: 10.1080/01496395.2013.872144] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|