1
|
Li M, Wan L, Law MK, Meng L, Jia Y, Mak PI, Martins RP. One-shot high-resolution melting curve analysis for KRAS point-mutation discrimination on a digital microfluidics platform. LAB ON A CHIP 2022; 22:537-549. [PMID: 34904611 DOI: 10.1039/d1lc00564b] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Single-nucleotide polymorphism (SNP) plays a critical role in personalized medicine, forensics, pharmacogenetics, and disease diagnostics. Among different existing SNP genotyping techniques, melting curve analysis (MCA) becomes increasingly popular due to its high accuracy and straightforward procedures in extracting the melting temperature (Tm). Yet, its study on existing digital microfluidic (DMF) platforms has intrinsic limitations due to the temperature inhomogeneity within a thickened droplet during the on-chip rapid heating process. Although the utilization of an on-chip thermostat can regulate and monitor the dynamic melting process in real time, the limited Tm accuracy resulting from the insufficient system response time to accommodate the fast-melting evolution still poses a great challenge for precise MCA with high throughput. This work proposes a one-shot MCA on a DMF platform. The tailoring of a functional substrate with hierarchical micro/nano structure enables high-resolution patterning of pL-scale droplets. Specifically, the hydrothermal and photocatalysis treatment allows the functional substrate to exhibit a superwettability contrast of >170°, facilitating passive isolation of the pL-scale DNA sample into highly-resolved pL droplets above the 200 μm superhydrophilic patterns. This high-resolution MCA technique can successfully discriminate KRAS gene targets with single-nucleotide mutations in 3 seconds. The high accuracy and consistency in the acquired Tm when compared with off-chip results demonstrate its opportunities for near-patient diagnostics, precision medicines, genetic counseling, and prevention strategies on DMF platforms.
Collapse
Affiliation(s)
- Mingzhong Li
- State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Taipa, Macao, China.
| | - Liang Wan
- State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Taipa, Macao, China.
- Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China
| | - Man-Kay Law
- State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Taipa, Macao, China.
- Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China
| | - Li Meng
- State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Taipa, Macao, China.
- Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China
| | - Yanwei Jia
- State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Taipa, Macao, China.
- Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China
| | - Pui-In Mak
- State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Taipa, Macao, China.
- Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China
| | - Rui P Martins
- State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Taipa, Macao, China.
- Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China
- On leave from Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| |
Collapse
|
2
|
Ferrara F, Zoupanou S, Primiceri E, Ali Z, Chiriacò MS. Beyond liquid biopsy: Toward non-invasive assays for distanced cancer diagnostics in pandemics. Biosens Bioelectron 2021; 196:113698. [PMID: 34688113 PMCID: PMC8527216 DOI: 10.1016/j.bios.2021.113698] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 10/01/2021] [Accepted: 10/07/2021] [Indexed: 12/11/2022]
Abstract
Liquid biopsy technologies have seen a significant improvement in the last decade, offering the possibility of reliable analysis and diagnosis from several biological fluids. The use of these technologies can overcome the limits of standard clinical methods, related to invasiveness and poor patient compliance. Along with this there are now mature examples of lab-on-chips (LOC) which are available and could be an emerging and breakthrough technology for the present and near-future clinical demands that provide sample treatment, reagent addition and analysis in a sample-in/answer-out approach. The possibility of combining non-invasive liquid biopsy and LOC technologies could greatly assist in the current need for minimizing exposure and transmission risks. The recent and ongoing pandemic outbreak of SARS-CoV-2, indeed, has heavily influenced all aspects of life worldwide. Ordinary tasks have been forced to switch from “in presence” to “distanced”, limiting the possibilities for a large number of activities in all fields of life outside of the home. Unfortunately, one of the settings in which physical distancing has assumed noteworthy consequences is the screening, diagnosis and follow-up of diseases. In this review, we analyse biological fluids that are easily collected without the intervention of specialized personnel and the possibility that they may be used -or not-for innovative diagnostic assays. We consider their advantages and limitations, mainly due to stability and storage and their integration into Point-of-Care diagnostics, demonstrating that technologies in some cases are mature enough to meet current clinical needs.
Collapse
Affiliation(s)
- Francesco Ferrara
- STMicroelectronics s.r.l., via per Monteroni, 73100, Lecce, Italy; CNR NANOTEC - Institute of Nanotechnology, via per Monteroni, 73100, Lecce, Italy.
| | - Sofia Zoupanou
- CNR NANOTEC - Institute of Nanotechnology, via per Monteroni, 73100, Lecce, Italy; University of Salento, Dept. of Mathematics & Physics E. de Giorgi, Via Arnesano, 73100, Lecce, Italy
| | - Elisabetta Primiceri
- CNR NANOTEC - Institute of Nanotechnology, via per Monteroni, 73100, Lecce, Italy
| | - Zulfiqur Ali
- University of Teesside, School of Health & Life Sciences, Healthcare Innovation Centre, Middlesbrough, TS1 3BX, Tees Valley, England, UK
| | | |
Collapse
|
3
|
Zhang M, Liu J, Shen Z, Liu Y, Song Y, Liang Y, Li Z, Nie L, Fang Y, Zhao Y. A newly developed paper embedded microchip based on LAMP for rapid multiple detections of foodborne pathogens. BMC Microbiol 2021; 21:197. [PMID: 34182947 PMCID: PMC8240391 DOI: 10.1186/s12866-021-02223-0] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Accepted: 04/30/2021] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND Microfluidic chip detection technology is considered a potent tool for many bioanalytic applications. Rapid detection of foodborne pathogens in the early stages is imperative to prevent the outbreak of foodborne diseases, known as a severe threat to human health. Conventional bacterial culture methods for detecting foodborne pathogens are time-consuming, laborious, and lacking in pathogen diagnosis. To overcome this problem, we have created an embedded paper-based microchip based on isothermal loop amplification (LAMP), which can rapidly and sensitively detect foodborne pathogens. RESULTS We embed paper impregnated with LAMP reagent and specific primers in multiple reaction chambers of the microchip. The solution containing the target pathogen was injected into the center chamber and uniformly distributed into the reaction chamber by centrifugal force. The purified DNA of Escherichia coli O157:H7, Salmonella spp., Staphylococcus aureus, and Vibrio parahaemolyticus has been successfully amplified and directly detected on the microchip. The E. coli O157:H7 DNA was identified as low as 0.0134 ng μL- 1. Besides, the potential of this microchip in point-of-care testing was further tested by combining the on-chip sample purification module and using milk spiked with Salmonella spp.. The pyrolyzed milk sample was filtered through a polydopamine-coated paper embedded in the inside of the sample chamber. It was transported to the reaction chamber by centrifugal force for LAMP amplification. Then direct chip detection was performed in the reaction chamber embedded with calcein-soaked paper. The detection limit of Salmonella spp. in the sample measured by the microchip was approximately 12 CFU mL- 1. CONCLUSION The paper embedded LAMP microchip offers inexpensive, user-friendly, and highly selective pathogen detection capabilities. It is expected to have great potential as a quick, efficient, and cost-effective solution for future foodborne pathogen detection.
Collapse
Affiliation(s)
- Mimi Zhang
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, 300072, China.
| | - Jinfeng Liu
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Zhiqiang Shen
- Tianjin Institute of Health and Environmental Medicine, A Key Laboratory of Risk Assessment and Control for Environment and Food Safety, Tianjin, 300050, China.
| | - Yongxin Liu
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Yang Song
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Yu Liang
- Tianjin Institute of Health and Environmental Medicine, A Key Laboratory of Risk Assessment and Control for Environment and Food Safety, Tianjin, 300050, China
| | - Zhende Li
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Lingmei Nie
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, 300072, China
| | - Yanjun Fang
- Tianjin Institute of Health and Environmental Medicine, A Key Laboratory of Risk Assessment and Control for Environment and Food Safety, Tianjin, 300050, China
| | - Youquan Zhao
- College of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, 300072, China.
| |
Collapse
|
4
|
Kopparthy VL, Crews ND. A versatile oscillating‐flow microfluidic PCR system utilizing a thermal gradient for nucleic acid analysis. Biotechnol Bioeng 2020; 117:1525-1532. [DOI: 10.1002/bit.27278] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2019] [Revised: 12/20/2019] [Accepted: 01/14/2020] [Indexed: 11/10/2022]
Affiliation(s)
- Varun L. Kopparthy
- Center for Biomedical Engineering and Rehabilitation Science (CBERS) Louisiana Tech University Ruston Louisiana
- Present address: Cleveland Clinic Cleveland Ohio
| | - Niel D. Crews
- Institute for Micromanufacturing (IfM) Louisiana Tech University Ruston Louisiana
| |
Collapse
|
5
|
Fu Y, Zhou X, Xing D. Lab-on-capillary: a rapid, simple and quantitative genetic analysis platform integrating nucleic acid extraction, amplification and detection. LAB ON A CHIP 2017; 17:4334-4341. [PMID: 29139529 DOI: 10.1039/c7lc01107e] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
In this work, we describe for the first time a genetic diagnosis platform employing a polydiallyldimethylammonium chloride (PDDA)-modified capillary and a liquid-based thermalization system for rapid, simple and quantitative DNA analysis with minimal user interaction. Positively charged PDDA is modified on the inner surface of the silicon dioxide capillary by using an electrostatic self-assembly approach that allows the negatively charged DNA to be separated from the lysate in less than 20 seconds. The capillary loaded with the PCR mix is incorporated in the thermalization system, which can achieve on-site real-time PCR. This system is based on the circulation of pre-heated liquids in the chamber, allowing for high-speed thermalization of the capillary and fast amplification. Multiple targets can be simultaneously analysed with multiplex spatial melting. Starting with live Escherichia coli (E. coli) cells in milk, as a realistic sample, the current method can achieve DNA extraction, amplification, and detection within 40 min.
Collapse
Affiliation(s)
- Yu Fu
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China.
| | | | | |
Collapse
|
6
|
A sample-to-answer, real-time convective polymerase chain reaction system for point-of-care diagnostics. Biosens Bioelectron 2017. [PMID: 28624618 DOI: 10.1016/j.bios.2017.06.014] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Timely and accurate molecular diagnostics at the point-of-care (POC) level is critical to global health. To this end, we propose a handheld convective-flow real-time polymerase chain reaction (PCR) system capable of direct sample-to-answer genetic analysis for the first time. Such a system mainly consists of a magnetic bead-assisted photothermolysis sample preparation, a closed-loop convective PCR reactor, and a wireless video camera-based real-time fluorescence detection. The sample preparation exploits the dual functionality of vancomycin-modified magnetic beads (VMBs) for bacteria enrichment and photothermal conversion, enabling cell pre-concentration and lysis to be finished in less than 3min. On the presented system, convective thermocycling is driven by a single-heater thermal gradient, and its amplification is monitored in real-time, with an analysis speed of less than 25min, a dynamic linear range from 106 to 101 copies/µL and a detection sensitivity of as little as 1 copies/µL. Additionally, the proposed PCR system is self-contained with a control electronics, pocket-size and battery-powered, providing a low-cost genetic analysis in a portable format. Therefore, we believe that this integrated system may become a potential candidate for fast, accurate and affordable POC molecular diagnostics.
Collapse
|
7
|
Karouia F, Peyvan K, Pohorille A. Toward biotechnology in space: High-throughput instruments for in situ biological research beyond Earth. Biotechnol Adv 2017; 35:905-932. [PMID: 28433608 DOI: 10.1016/j.biotechadv.2017.04.003] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2016] [Revised: 03/27/2017] [Accepted: 04/12/2017] [Indexed: 12/18/2022]
Abstract
Space biotechnology is a nascent field aimed at applying tools of modern biology to advance our goals in space exploration. These advances rely on our ability to exploit in situ high throughput techniques for amplification and sequencing DNA, and measuring levels of RNA transcripts, proteins and metabolites in a cell. These techniques, collectively known as "omics" techniques have already revolutionized terrestrial biology. A number of on-going efforts are aimed at developing instruments to carry out "omics" research in space, in particular on board the International Space Station and small satellites. For space applications these instruments require substantial and creative reengineering that includes automation, miniaturization and ensuring that the device is resistant to conditions in space and works independently of the direction of the gravity vector. Different paths taken to meet these requirements for different "omics" instruments are the subjects of this review. The advantages and disadvantages of these instruments and technological solutions and their level of readiness for deployment in space are discussed. Considering that effects of space environments on terrestrial organisms appear to be global, it is argued that high throughput instruments are essential to advance (1) biomedical and physiological studies to control and reduce space-related stressors on living systems, (2) application of biology to life support and in situ resource utilization, (3) planetary protection, and (4) basic research about the limits on life in space. It is also argued that carrying out measurements in situ provides considerable advantages over the traditional space biology paradigm that relies on post-flight data analysis.
Collapse
Affiliation(s)
- Fathi Karouia
- University of California San Francisco, Department of Pharmaceutical Chemistry, San Francisco, CA 94158, USA; NASA Ames Research Center, Exobiology Branch, MS239-4, Moffett Field, CA 94035, USA; NASA Ames Research Center, Flight Systems Implementation Branch, Moffett Field, CA 94035, USA.
| | | | - Andrew Pohorille
- University of California San Francisco, Department of Pharmaceutical Chemistry, San Francisco, CA 94158, USA; NASA Ames Research Center, Exobiology Branch, MS239-4, Moffett Field, CA 94035, USA.
| |
Collapse
|
8
|
Nestorova GG, Hasenstein K, Nguyen N, DeCoster MA, Crews ND. Lab-on-a-chip mRNA purification and reverse transcription via a solid-phase gene extraction technique. LAB ON A CHIP 2017; 17:1128-1136. [PMID: 28232986 DOI: 10.1039/c6lc01421f] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Extraction and purification of high quality RNA is a crucial initial step required for a variety of genomic assays. We report a solid phase gene extraction (SPGE) method for automated extraction, purification and reverse transcription of mRNA in a microfluidic device. This is performed using a 130 μm diameter stainless steel needle that is amino-linked to dT(15) oligonucleotides for selective hybridization of mRNA. By inserting this probe into the biological sample for only 30 seconds, mRNA is captured with high selectivity and a yield greater than 10 pg per mm of probe length. The probe is then inserted into a lab-on-a-chip device, where the bound poly-adenylated RNA is thermally released and immediately reverse transcribed for subsequent PCR amplification. The insertion of the probe into the microfluidic device is straightforward: the microchannel is formed with an elastomer (PDMS) that, when punctured, will seal around the probe. The specificity and RNA loading capacity of the probes were evaluated using conventional qPCR. This procedure was successfully used to extract, purify, and transcribe mRNA from rat glioblastoma cell spheroids in less than seven minutes. Analysis of the product confirmed that the SPGE technique selectively captures and inherently purifies high-quality mRNA directly from biological material with no need for additional pre-processing steps. Integrating this elegant sample preparation method into a complete lab-on-a-chip system will substantially enhance the speed and automation of mRNA assays for research and clinical diagnostics.
Collapse
Affiliation(s)
- Gergana G Nestorova
- Institute for Micromanufacturing, Louisiana Tech University, Ruston, LA, USA. and Department of Biological Sciences, Louisiana Tech University, Ruston, LA, USA
| | - Karl Hasenstein
- Biology Department, University of Louisiana at Lafayette, Lafayette, LA, USA
| | - Nam Nguyen
- Biomedical Engineering Department, Louisiana Tech University, Ruston, LA, USA
| | - Mark A DeCoster
- Institute for Micromanufacturing, Louisiana Tech University, Ruston, LA, USA. and Biomedical Engineering Department, Louisiana Tech University, Ruston, LA, USA
| | - Niel D Crews
- Institute for Micromanufacturing, Louisiana Tech University, Ruston, LA, USA.
| |
Collapse
|
9
|
HE QD, HUANG DP, HUANG G, CHEN ZG. Advance in Research of Microfluidic Polymerase Chain Reaction Chip. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2016. [DOI: 10.1016/s1872-2040(16)60921-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
10
|
Comina G, Suska A, Filippini D. Towards autonomous lab-on-a-chip devices for cell phone biosensing. Biosens Bioelectron 2016; 77:1153-67. [DOI: 10.1016/j.bios.2015.10.092] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2015] [Revised: 10/29/2015] [Accepted: 10/30/2015] [Indexed: 01/20/2023]
|
11
|
Wang H, Liu W, Zhang X, Xu X, Kang Z, Li S, Wu Z, Yang Z, Yao B, Guan M. Toward point-of-care testing for JAK2 V617F mutation on a microchip. J Chromatogr A 2015; 1410:28-34. [PMID: 26235214 DOI: 10.1016/j.chroma.2015.07.079] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2015] [Revised: 07/09/2015] [Accepted: 07/18/2015] [Indexed: 02/01/2023]
Abstract
Molecular genetics now plays a crucial role in diagnosis, the identification of prognostic markers, and monitoring of hematological malignancies. Demonstration of acquired changes such as the JAK2 V617F mutation within myeloproliferative neoplasms (MPN) has quickly moved from a research setting to the diagnostic laboratory. Microfluidics-based assays can reduce the assay time and sample/reagent consumption and enhance the reaction efficiency; however, no current assay has integrated isothermal amplification for point-of-care MPN JAK2 V617F mutation testing with a microchip. In this report, an integrated microchip that performs the whole human blood genomic DNA extraction, loop-mediated isothermal nucleic acid amplification (LAMP) and visual detection for point-of-care genetic mutation testing is demonstrated. This method was validated on DNA from cell lines as well as on whole blood from patients with MPN. The results were compared with those obtained by unlabeled probe melting curve analysis. This chip enjoys a high accuracy, operability, and cost/time efficiency within 1h. All these benefits provide the chip with a potency toward a point-of-care genetic analysis. All samples identified as positive by unlabeled probe melting curve analysis (n=27) proved positive when tested by microchip assay. None of the 30 negative controls gave false positive results. In addition, a patient with polycythemia vera diagnosed as being JAK2 V617F-negative by unlabeled probe melting curve analysis was found to be positive by the microchip. This microchip would possibly be very attractive in developing a point-of-care platform for quick preliminary diagnosis of MPN or other severe illness in resource-limited settings.
Collapse
Affiliation(s)
- Hua Wang
- Department of Laboratory Medicine, Huashan Hospital, Shanghai Medical College, Fudan University, Shanghai 200040, China
| | - Weiwei Liu
- Department of Laboratory Medicine, Shanghai Tenth People's Hospital, Tongji University, Shanghai 200072, China
| | - Xinju Zhang
- Center of Laboratory, Huashan Hospital, Shanghai Medical College, Fudan University, Shanghai 200040, China
| | - Xiao Xu
- Center of Laboratory, Huashan Hospital, Shanghai Medical College, Fudan University, Shanghai 200040, China
| | - Zhihua Kang
- Department of Laboratory Medicine, Huashan Hospital, Shanghai Medical College, Fudan University, Shanghai 200040, China; Center of Laboratory, Huashan Hospital, Shanghai Medical College, Fudan University, Shanghai 200040, China
| | - Shibao Li
- Department of Laboratory Medicine, Huashan Hospital, Shanghai Medical College, Fudan University, Shanghai 200040, China; Center of Laboratory, Huashan Hospital, Shanghai Medical College, Fudan University, Shanghai 200040, China
| | - Zhiyuan Wu
- Department of Laboratory Medicine, Huashan Hospital, Shanghai Medical College, Fudan University, Shanghai 200040, China; Center of Laboratory, Huashan Hospital, Shanghai Medical College, Fudan University, Shanghai 200040, China
| | - Zhiliu Yang
- Institute of Microanalytical Systems, Department of Chemistry, Zhejiang University, Hangzhou 310058, China
| | - Bo Yao
- Institute of Microanalytical Systems, Department of Chemistry, Zhejiang University, Hangzhou 310058, China.
| | - Ming Guan
- Department of Laboratory Medicine, Huashan Hospital, Shanghai Medical College, Fudan University, Shanghai 200040, China; Center of Laboratory, Huashan Hospital, Shanghai Medical College, Fudan University, Shanghai 200040, China.
| |
Collapse
|
12
|
A miniature quantitative PCR device for directly monitoring a sample processing on a microfluidic rapid DNA system. Biomed Microdevices 2015; 16:905-14. [PMID: 25106501 DOI: 10.1007/s10544-014-9895-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
We report a microfluidic device and measurement method to perform real-time PCR (or qPCR) in a miniaturized configuration for on-chip implementation using reaction volumes of less than 20 μL. The qPCR bioreactor is designed as a module to be embedded in an automated sample-in/profile-out system for rapid DNA biometrics or human identification. The PCR mixture is excited with a 505 nm diode-pumped solid-state laser (DPSSL) and the fluorescence build-up is measured using optical fibers directly embedded to the sidewalls of the microfluidic qPCR bioreactor. We discuss manufacturing and operating parameters necessary to adjust the internal surface conditions and temperature profiles of the bioreactor and to optimize the yield and quality of the PCR reaction for the amplification of 62 bp hTERT intron fragments using the commercial Quantifiler® kit (Life Technologies, Carlsbad, CA) commonly accepted for genotyping analysis. We designed a microfluidic device suitable for continuously processing a specimen by efficiently mixing the reagents from the kit to a set volume of DNA template on chip. Our approach relies on a calibration curve for the specific device using control DNA. We successfully applied this method to determine the concentration of genomic DNA extracted from a buccal swab on separate microfluidic devices which are operated upstream the qPCR device and perform buccal swab lysis and buccal DNA extraction. A precise correlation between the amount determined on chip and that obtained using a commercial cycler is demonstrated.
Collapse
|
13
|
Shu B, Zhang C, Xing D. A handheld flow genetic analysis system (FGAS): towards rapid, sensitive, quantitative and multiplex molecular diagnosis at the point-of-care level. LAB ON A CHIP 2015; 15:2597-605. [PMID: 25953325 DOI: 10.1039/c5lc00139k] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
A handheld flow genetic analysis system (FGAS) is proposed for rapid, sensitive, multiplex and real-time quantification of nucleic acids at the point-of-care (POC) level. The FGAS includes a helical thermal-gradient microreactor and a microflow actuator, as well as control circuitry for temperature, fluid and power management, and smartphone fluorescence imaging. All of these features are integrated into a field-portable and easy-to-use molecular diagnostic platform powered by lithium batteries. Due to the unique design of the microreactor, not only steady temperatures for denaturation and annealing/extension but also a linear thermal gradient for spatial high-resolution melting can be achieved through simply maintaining a single heater at constant temperature. The smartphone fluorescence imaging system has a wide field of view that captures all PCR channels of the microreactor in a single snapshot without the need for any mechanical scanning. By these designs, the FGAS enables real-time monitoring of the temporal and spatial fluorescence signatures of amplicons during continuous-flow amplification. On the current FGAS, visual detection of as little as 10 copies per μL of genomic DNA of Salmonella enterica was achieved in 15 min, with real-time quantitative detection of the DNA over 6 orders of magnitude concentration from 10(6) to 10(1) copies per μL also completed in 7.5-15 min. In addition, multiple pathogenic DNA targets could be simultaneously discriminated with direct bar-chart readout or multiplex spatial melting in serial flow. We anticipate that the FGAS has great potential to become a next-generation gene analyzer for POC molecular diagnostics.
Collapse
Affiliation(s)
- Bowen Shu
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China.
| | | | | |
Collapse
|
14
|
Le Roux D, Root BE, Hickey JA, Scott ON, Tsuei A, Li J, Saul DJ, Chassagne L, Landers JP, de Mazancourt P. An integrated sample-in-answer-out microfluidic chip for rapid human identification by STR analysis. LAB ON A CHIP 2014; 14:4415-4425. [PMID: 25248520 DOI: 10.1039/c4lc00685b] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
A fully integrated microfluidic chip for human identification by short tandem repeat (STR) analysis that includes a unique enzymatic liquid preparation of the DNA, microliter non-contact PCR, and a polymer that allows a high-resolution separation within a compact microchip footprint has been developed. A heat-activated enzyme that digests biological materials is employed to generate the target yield of DNA from a buccal swab or FTA paper. The microfluidic architecture meters an aliquot of the liberated DNA and mixes it with the PCR reagents prior to non-contact IR-mediated PCR amplification. The products of PCR amplification are mixed with a sizing standard (ladder) and the 18-plex STR amplicons are separated in an effective length (Leff) of just 7 cm. The development, optimization and integration of each of these processes within the microfluidic chip are described. The device is able to generate genetic profiles in approximately 2 hours that match the profiles from the conventional processes performed using separate conventional instruments. Analysis is performed on a single plastic microchip with a size similar to that of a 96-well plate and only a few mm thick with no pretreatment of any of the functional domains. This is significant advancement in terms of ease of fabrication over glass microdevices or polymeric systems assembled from multiple components. Consequently, this fully integrated sample-in-answer-out microchip is an important step toward generation of a rapid micro-total analysis system for point-of-collection human identification based on genetic analysis.
Collapse
Affiliation(s)
- Delphine Le Roux
- Versailles - Saint Quentin en Yvelines University, 55 Avenue de Paris, 78000 Versailles, France.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Knez K, Spasic D, Janssen KPF, Lammertyn J. Emerging technologies for hybridization based single nucleotide polymorphism detection. Analyst 2014; 139:353-70. [PMID: 24298558 DOI: 10.1039/c3an01436c] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Detection of single nucleotide polymorphisms (SNPs) is a crucial challenge in the development of a novel generation of diagnostic tools. Accurate detection of SNPs can prove elusive, as the impact of a single variable nucleotide on the properties of a target sequence is limited, even if this sequence consists of only a few nucleotides. New, accurate and facile strategies for the detection of point mutations are therefore absolutely necessary for the increased adoption of point-of-care molecular diagnostics. Currently, PCR and sequencing are mostly applied for diagnosing SNPs. However these methods have serious drawbacks as routine diagnostic tools because of their labour intensity and cost. Several new, more suitable methods can be applied to enable sensitive detection of mutations based on specially designed hybridization probes, mutation recognizing enzymes and thermal denaturation. Here, an overview is presented of the most recent advances in the field of fast and sensitive SNP detection assays with strong potential for integration in point-of-care tests.
Collapse
Affiliation(s)
- Karel Knez
- KU Leuven, BIOSYST-MeBioS, Willem de Croylaan 42, Leuven, Belgium.
| | | | | | | |
Collapse
|
16
|
Cardoso VF, Knoll T, Velten T, Rebouta L, Mendes PM, Lanceros-Méndez S, Minas G. Polymer-based acoustic streaming for improving mixing and reaction times in microfluidic applications. RSC Adv 2014. [DOI: 10.1039/c3ra46420b] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
17
|
Cho W, Maeng JH, Ahn Y, Hwang SY. Disposable on-chip microfluidic system for buccal cell lysis, DNA purification, and polymerase chain reaction. Electrophoresis 2013; 34:2531-7. [DOI: 10.1002/elps.201300230] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2013] [Revised: 05/27/2013] [Accepted: 05/28/2013] [Indexed: 11/07/2022]
Affiliation(s)
- Woong Cho
- Graduate School; Hanyang University; Seoul Korea
| | - Joon-Ho Maeng
- Department of Biochemistry; Hanyang University; Ansan, Gyeonggi-do Korea
| | - Yoomin Ahn
- Department of Mechanical Engineering; Hanyang University; Ansan, Gyeonggi-do Korea
| | - Seung Yong Hwang
- Division of Molecular and Life Science; Hanyang University; Ansan, Gyeonggi-do Korea
- GenoCheck Co. Ltd., Hanyang University; Ansan, Gyeonggi-do Korea
| |
Collapse
|
18
|
Oblath EA, Henley WH, Alarie JP, Ramsey JM. A microfluidic chip integrating DNA extraction and real-time PCR for the detection of bacteria in saliva. LAB ON A CHIP 2013; 13:1325-32. [PMID: 23370016 PMCID: PMC3617581 DOI: 10.1039/c3lc40961a] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
A microfluidic chip integrating DNA extraction, amplification, and detection for the identification of bacteria in saliva is described. The chip design integrated a monolithic aluminum oxide membrane (AOM) for DNA extraction with seven parallel reaction wells for real-time polymerase chain reaction (rtPCR) amplification of the extracted DNA. Samples were first heated to lyse target organisms and then added to the chip and filtered through the nanoporous AOM to extract the DNA. PCR reagents were added to each of the wells and the chip was thermocycled. Identification of Streptococcus mutans in a saliva sample is demonstrated along with the detection of 300 fg (100-125 copies) of both methicillin-susceptible Staphylococcus aureus (MSSA) and methicillin-resistant S. aureus (MRSA) genomic DNA (gDNA) spiked into a saliva sample. Multiple target species and strains of bacteria can be simultaneously identified in the same sample by varying the primers and probes used in each of the seven reaction wells. In initial tests, as little as 30 fg (8-12 copies) of MSSA gDNA in buffer has been successfully amplified and detected with this device.
Collapse
Affiliation(s)
- Emily A Oblath
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA
| | | | | | | |
Collapse
|