1
|
Al-Tamimi M, Altarawneh S, Mustafa MA, El-Sallaq M, Shihab P. Quantitative and equipment-free paper-based agglutination assay of bacterial cells. RSC Adv 2024; 14:20516-20528. [PMID: 38946760 PMCID: PMC11209875 DOI: 10.1039/d4ra03001j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Accepted: 06/06/2024] [Indexed: 07/02/2024] Open
Abstract
Background: point-of-care (POC) tests are useful for bedside/home applications, emergencies, frequent follow-ups, and resource-limited areas. Limited quantitative and equipment-free POC assays have been reported. This study aims to develop, validate, and apply a simple, quantitative, paper-based POC assay. Methods: wax-channeled paper treated with specific anti-Brucella and anti-Salmonella antibodies was used for distance-based chromatographic elution of stained bacterial cell agglutinations. Results: a qualitative paper-based agglutination POC test was developed using color intensity, tail appearance, and "+/-" signs that clearly distinguish the positive and negative results. The optimization of the test for paper type, microfluidic channel design, antibody and bacterial cell concentrations, and elution methods was carried out. Quantitative assay transformation was successfully developed using the color intensity of the original reaction zone, intensity of elution tail, and distance-based migration that correspond to bacterial agglutination size. The migration distance of eluted bacterial agglutination bands corresponds to the target concentration with good linearity and minimal variability. Reporting of colored band migration with numbers using microfluidic patterns was used to enhance non-technical end-user applications. A distance-based POC assay prototype was then successfully used for the accurate detection of known and unknown samples in comparison with standard assays. Conclusions: the migration distance of an eluted stained bacterial agglutination correlated with anti-bacterial antibody concentrations. A simple, cheap, quantitative, and equipment-free paper-based POC assay of bacterial cell agglutination was developed. This test can be used for simple "+/-" results, thermometer-like quantification, or text reporting with numbers corresponding to target concentrations. The assay has extended applications to different human disease biomarkers.
Collapse
Affiliation(s)
- Mohammad Al-Tamimi
- Department of Microbiology, Pathology and Forensic Medicine, Faculty of Medicine, The Hashemite University Zarqa Jordan +962 (5) 3826613 +962 (5) 3903333
| | - Shahed Altarawneh
- Department of Microbiology, Pathology and Forensic Medicine, Faculty of Medicine, The Hashemite University Zarqa Jordan +962 (5) 3826613 +962 (5) 3903333
| | - Minas A Mustafa
- Department of Medical Laboratory Sciences, Faculty of Applied Medical Sciences, The Hashemite University Zarqa Jordan
| | - Mariam El-Sallaq
- Department of Microbiology, Pathology and Forensic Medicine, Faculty of Medicine, The Hashemite University Zarqa Jordan +962 (5) 3826613 +962 (5) 3903333
| | - Penelope Shihab
- Wyoming Center for Entrepreneurship and Innovation, University of Wyoming WY USA
| |
Collapse
|
2
|
Khachornsakkul K, Leelasattarathkul T. Photothermal biosensing integrated with microfluidic paper-based analytical device for sensitive quantification of sarcosine. Talanta 2024; 271:125628. [PMID: 38219320 DOI: 10.1016/j.talanta.2024.125628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 11/13/2023] [Accepted: 01/04/2024] [Indexed: 01/16/2024]
Abstract
This article presents the development of a photothermal biosensing integrated with microfluidic paper-based analytical device (PT-μPAD) as a quantitative biosensor method for monitoring sarcosine in human control urine, plasma, and serum samples. The device utilizes gold nanoparticles (AuNPs) as both a peroxidase-like nanozyme and a photothermal substrate to enable sarcosine detection. In our PT-μPAD, hydrogen peroxide (H2O2) is generated through the oxidation of sarcosine by a sarcosine oxidase (SOx) enzyme. Subsequently, the H2O2 flows through the paper microchannels to the detection zone, where it etches the pre-deposited AuNPs, inducing a temperature change upon exposure by a 532 nm laser. The temperature variation is then measured using a portable and inexpensive infrared thermometer. Under optimized conditions, we obtained a linear range between 10.0 and 40.0 nmol L-1 (R2 = 0.9954) and a detection limit (LOD) of 32.0 pmol L-1. These values fall within the clinical range for sarcosine monitoring in prostate cancer diagnostics in humans. Moreover, our approach exhibits high selectivity without interfering effects. Recovery studies in various human control samples demonstrated a range of 99.05-102.11 % with the highest RSD of 2.25 %. The PT-μPAD was further validated for sarcosine determination in human control urine and compared with a commercial ELISA assay, revealing no significant difference between these two methods at a 95 % confidence level. Overall, our proposed sarcosine biosensor is well-suited for prostate cancer monitoring, given its affordability, sensitivity, and user-friendliness, even for unskilled individuals. Moreover, this strategy has promising prospects for broader applications, potentially detecting various biomarkers as a point-of-care (POC) diagnostic tool.
Collapse
Affiliation(s)
- Kawin Khachornsakkul
- Division of Chemistry, Department of Science, Faculty of Science and Technology, Rajamangala University of Technology Krungthep, Bangkok, 10120, Thailand; Department of Electrical and Computer Engineering, Tufts University, Medford, MA, 02155, USA
| | - Tapparath Leelasattarathkul
- Division of Chemistry, Department of Science, Faculty of Science and Technology, Rajamangala University of Technology Krungthep, Bangkok, 10120, Thailand.
| |
Collapse
|
3
|
Moreira NS, Pinheiro KMP, Sousa LR, Garcia GDS, Figueredo F, Coltro WKT. Distance-based detection of paracetamol in microfluidic paper-based analytical devices for forensic application. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 16:33-39. [PMID: 38010169 DOI: 10.1039/d3ay01739g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2023]
Abstract
Whisky adulteration is a prevalent practice driven by the high cost of these beverages. Counterfeiters commonly dilute whisky with less expensive alcoholic beverages, water, food additives, drugs or pharmaceuticals. Paracetamol (PAR), an analgesic drug that mitigates hangovers and headaches, is commonly used to adulterate whisky. Currently, the primary method for quantifying PAR levels is high-performance liquid chromatography, but this technique is both time consuming and usually generates more residues. In this context, the utilization of miniaturized and portable analytical devices becomes imperative for conducting point-of-care/need analyses. These devices offer several advantages, including portability, user-friendliness, low cost, and minimal material wastage. This study proposes the selective distance-based PAR quantification on whisky samples using a paper-based microfluidic analytical device (μPAD). Colorimetric detection on paper-based platforms offers great benefits such as affordability, portability, and the ability to detect PAR without complicated instrumentation. The optimal detection conditions were achieved by introducing 5 μL of a mixture containing 7.5 mmol L-1 of Fe(III) and K3[Fe(CN)6] into the detection zone, along with 12 μL of whisky samples into the sample zone. The method exhibited linear behavior within the concentration range from 15 to 120 mg L-1, with a determination coefficient of 0.998. PAR was quantified in adulterated samples. The results obtained with the paper-based devices were compared with a referenced method, and no significant differences were observed at a confidence level of 95%. The μPAD allowed to determine ca. 1 drop of pharmaceutical medicine PAR of 200 mg mL-1 in 1 L of solution, demonstrating excellent sensitivity. This method offers cost-effective and rapid analysis, reducing the consumption of samples, reagents, and wastes. Consequently, it could be considered a viable and portable alternative for analyzing beverages at criminal scenes, customs, and police operations, thereby enhancing the field of forensics.
Collapse
Affiliation(s)
- Nikaele S Moreira
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil.
| | - Kemilly M P Pinheiro
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil.
| | - Lucas R Sousa
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil.
- Laboratorio de Biosensores y Bioanálisis (LABB), Departamento de Química Biológica e IQUIBICEN - CONICET, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires (UBA), Pabellón 2, Ciudad Universitaria, Ciudad Autónoma de Buenos Aires, Argentina
| | - Gabriel D S Garcia
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil.
| | - Federico Figueredo
- Laboratorio de Biosensores y Bioanálisis (LABB), Departamento de Química Biológica e IQUIBICEN - CONICET, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires (UBA), Pabellón 2, Ciudad Universitaria, Ciudad Autónoma de Buenos Aires, Argentina
| | - Wendell K T Coltro
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil.
- Laboratorio de Biosensores y Bioanálisis (LABB), Departamento de Química Biológica e IQUIBICEN - CONICET, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires (UBA), Pabellón 2, Ciudad Universitaria, Ciudad Autónoma de Buenos Aires, Argentina
- Instituto Nacional de Ciência e Tecnologia de Bioanalítica, 13084-971, Campinas, SP, Brazil
| |
Collapse
|
4
|
Mettakoonpitak J, Sawatdichai N, Thepnuan D, Siripinyanond A, Henry CS, Chantara S. Microfluidic paper-based analytical devices for simultaneous detection of oxidative potential and copper in aerosol samples. Mikrochim Acta 2023; 190:241. [PMID: 37243836 DOI: 10.1007/s00604-023-05819-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Accepted: 05/02/2023] [Indexed: 05/29/2023]
Abstract
The potential reach of point-of-care (POC) diagnostics into daily routines for exposure to reactive oxygen species (ROS) and Cu in aerosolized particulate matter (PM) demands that microfluidic paper-based analytical devices (μPADs) take into consideration the simple detection of these toxic PM components. Here, we propose μPADs with a dual-detection system for simultaneous ROS and Cu(II) detection. For colorimetric ROS detection, the glutathione (GSH) assay with a folding design to delay the reaction yielded complete ROS and GSH oxidation, and improved homogeneity of color development relative to using the lateral flow pattern. For electrochemical Cu(II) determination, 1,10-phenanthroline/Nafion modified graphene screen-printed electrodes showed ability to detect Cu(II) down to pg level being low enough to be applied to PM analysis. No intra- and inter-interference affecting both systems were found. The proposed μPADs obtained LODs for 1,4-naphthoquinone (1,4-NQ), used as the ROS representative, and Cu(II) of 8.3 ng and 3.6 pg, respectively and linear working ranges of 20 to 500 ng for ROS and 1 × 10-2 to 2 × 102 ng for Cu(II). Recovery of the method was between 81.4 and 108.3% for ROS and 80.5-105.3% for Cu(II). Finally, the sensors were utilized for simultaneous ROS and Cu(II) determination in PM samples and the results statistically agreed with those using the conventional methods at 95% confidence.
Collapse
Affiliation(s)
- Jaruwan Mettakoonpitak
- Department of Chemistry, Faculty of Science and Technology, Rambhai Barni Rajabhat University, Chantaburi, 22000, Thailand.
| | - Nalatthaporn Sawatdichai
- Department of Chemistry, Faculty of Science and Technology, Rambhai Barni Rajabhat University, Chantaburi, 22000, Thailand
| | - Duangduean Thepnuan
- Department of Chemistry, Faculty of Science and Technology, Chiang Mai Rajabhat University, Chiang Mai, 50300, Thailand
| | - Atitaya Siripinyanond
- Department of Chemistry and Center for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama VI Road, Bangkok, 10400, Thailand
| | - Charles S Henry
- Department of Chemistry, Colorado State University, Fort Collins, Colorado, 80523, USA
| | - Somporn Chantara
- Environmental Science Research Center, Faculty of Science, Chiang Mai University, Chiang Mai, 50200, Thailand
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, 50200, Thailand
| |
Collapse
|
5
|
Enhancing of detection resolution via designing of a multi-functional 3D connector between sampling and detection zones in distance-based microfluidic paper-based analytical device: multi-channel design for multiplex analysis. Mikrochim Acta 2022; 189:482. [DOI: 10.1007/s00604-022-05585-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2022] [Accepted: 11/17/2022] [Indexed: 12/03/2022]
|
6
|
Khachornsakkul K, Phuengkasem D, Palkuntod K, Sangkharoek W, Jamjumrus O, Dungchai W. A Simple Counting-Based Measurement for Paper Analytical Devices and Their Application. ACS Sens 2022; 7:2093-2101. [PMID: 35736786 DOI: 10.1021/acssensors.2c01003] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
This work introduces the concept of a counting-based measurement on paper analytical devices (cPADs) to improve the utilization of numerous reactions. The design of cPADs consists of two layers of paper substrates; the first layer contains a central sample zone combined with a radial surrounded by 12 detection zones that are predeposited with the various reagents, and the second layer acts as a connection channel between the sample zone and each detection zone. The solution can vertically flow from the first to the second layer and then move through the area to each subsequent detection zone. The analyte level can be evaluated by counting the number of detection zones that change color from a blank signal. Furthermore, our cPADs exhibit a capability of implementation for a broad series of reactions. Compared to the dPAD technique, some reactions that are possibly difficult to apply in such devices can be wholly enabled in our devices. The final color reaction on cPADs can apparently occur due to its identity. We applied this technique to the monitoring of carbaryl (CBR) and copper ions (Cu2+) using different reactions, including azo-coupling and complexation, respectively. Accordingly, this indicates an excellent result validated using the more traditional methods. Our cPADs can be applied for rapid screening of both CBR and Cu2+ in water samples with outstanding accuracy and precision using a naked-eye measurement by a relatively unskilled person. We offer a simple platform on PADs for rapid screening, combining high cost-effectiveness within a miniaturized platform designed for use with onsite applications, which is thus suitable for several different reactions.
Collapse
Affiliation(s)
- Kawin Khachornsakkul
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok 10140, Thailand
| | - Danai Phuengkasem
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok 10140, Thailand
| | - Kitiya Palkuntod
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok 10140, Thailand
| | - Wuttichai Sangkharoek
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok 10140, Thailand
| | - Opor Jamjumrus
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok 10140, Thailand
| | - Wijitar Dungchai
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok 10140, Thailand
| |
Collapse
|
7
|
Ezrre S, Reyna MA, Anguiano C, Avitia RL, Márquez H. Lab-on-a-Chip Platforms for Airborne Particulate Matter Applications: A Review of Current Perspectives. BIOSENSORS 2022; 12:191. [PMID: 35448251 PMCID: PMC9024784 DOI: 10.3390/bios12040191] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/12/2022] [Revised: 03/12/2022] [Accepted: 03/16/2022] [Indexed: 06/14/2023]
Abstract
Lab-on-a-Chip (LoC) devices are described as versatile, fast, accurate, and low-cost platforms for the handling, detection, characterization, and analysis of a wide range of suspended particles in water-based environments. However, for gas-based applications, particularly in atmospheric aerosols science, LoC platforms are rarely developed. This review summarizes emerging LoC devices for the classification, measurement, and identification of airborne particles, especially those known as Particulate Matter (PM), which are linked to increased morbidity and mortality levels from cardiovascular and respiratory diseases. For these devices, their operating principles and performance parameters are introduced and compared while highlighting their advantages and disadvantages. Discussing the current applications will allow us to identify challenges and determine future directions for developing more robust LoC devices to monitor and analyze airborne PM.
Collapse
Affiliation(s)
- Sharon Ezrre
- Instituto de Ingeniería, Universidad Autónoma de Baja California (UABC), Mexicali 21100, Mexico;
| | - Marco A. Reyna
- Instituto de Ingeniería, Universidad Autónoma de Baja California (UABC), Mexicali 21100, Mexico;
| | - Citlalli Anguiano
- Facultad de Ingeniería, Universidad Autónoma de Baja California (UABC), Mexicali 21280, Mexico; (C.A.); (R.L.A.)
| | - Roberto L. Avitia
- Facultad de Ingeniería, Universidad Autónoma de Baja California (UABC), Mexicali 21280, Mexico; (C.A.); (R.L.A.)
| | - Heriberto Márquez
- Departamento de Óptica, Centro de Investigación Científica y de Educación Superior de Ensenada (CICESE), Ensenada 22860, Mexico;
| |
Collapse
|
8
|
Zhang H, Xia C, Feng G, Fang J. Hospitals and Laboratories on Paper-Based Sensors: A Mini Review. SENSORS 2021; 21:s21185998. [PMID: 34577205 PMCID: PMC8472957 DOI: 10.3390/s21185998] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 09/01/2021] [Accepted: 09/02/2021] [Indexed: 02/07/2023]
Abstract
With characters of low cost, portability, easy disposal, and high accuracy, as well as bulky reduced laboratory equipment, paper-based sensors are getting increasing attention for reliable indoor/outdoor onsite detection with nonexpert operation. They have become powerful analysis tools in trace detection with ultra-low detection limits and extremely high accuracy, resulting in their great popularity in medical detection, environmental inspection, and other applications. Herein, we summarize and generalize the recently reported paper-based sensors based on their application for mechanics, biomolecules, food safety, and environmental inspection. Based on the biological, physical, and chemical analytes-sensitive electrical or optical signals, extensive detections of a large number of factors such as humidity, pressure, nucleic acid, protein, sugar, biomarkers, metal ions, and organic/inorganic chemical substances have been reported via paper-based sensors. Challenges faced by the current paper-based sensors from the fundamental problems and practical applications are subsequently analyzed; thus, the future directions of paper-based sensors are specified for their rapid handheld testing.
Collapse
|
9
|
Flieger J, Franus W, Panek R, Szymańska-Chargot M, Flieger W, Flieger M, Kołodziej P. Green Synthesis of Silver Nanoparticles Using Natural Extracts with Proven Antioxidant Activity. Molecules 2021; 26:4986. [PMID: 34443574 PMCID: PMC8398508 DOI: 10.3390/molecules26164986] [Citation(s) in RCA: 40] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 08/14/2021] [Accepted: 08/15/2021] [Indexed: 12/20/2022] Open
Abstract
Natural extracts are a rich source of biomolecules that are useful not only as antioxidant drugs or diet supplements but also as complex reagents for the biogenic synthesis of metallic nanoparticles. The natural product components can act as strong reducing and capping substrates guaranteeing the stability of formed NPs. The current work demonstrates the suitability of extracts of Camellia sinensis, Ilex paraguariensis, Salvia officinalis, Tilia cordata, Levisticum officinale, Aegopodium podagraria, Urtica dioica, Capsicum baccatum, Viscum album, and marine algae Porphyra Yezoensis for green synthesis of AgNPs. The antioxidant power of methanolic extracts was estimated at the beginning according to their free radical scavenging activity by the DPPH method and reducing power activity by CUPRAC and SNPAC (silver nanoparticle antioxidant capacity) assays. The results obtained by the CUPRAC and SNAPC methods exhibited excellent agreement (R2~0.9). The synthesized AgNPs were characterized by UV-vis spectroscopy, Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), energy dispersive X-ray analysis (EDX), dynamic light scattering (DLS) particle size, and zeta potential. The UV-vis absorption spectra showed a peak at 423 nm confirming the presence of AgNPs. The shapes of extract-mediated AgNPs were mainly spherical, spheroid, rod-shaped, agglomerated crystalline structures. The NPs exhibited a high negative zeta potential value in the range from -49.8 mV to -56.1 mV, proving the existence of electrostatic stabilization. FTIR measurements indicated peaks corresponding to different functional groups such as carboxylic acids, alcohol, phenol, esters, ethers, aldehydes, alkanes, and proteins, which were involved in the synthesis and stabilization of AgNPs. Among the examined extracts, green tea showed the highest activity in all antioxidant tests and enabled the synthesis of the smallest nanoparticles, namely 62.51, 61.19, and 53.55 nm, depending on storage times of 30 min, 24 h, and 72 h, respectively. In turn, the Capsicum baccatum extract was distinguished by the lowest zeta potential, decreasing with storage time from -66.0 up to -88.6 mM.
Collapse
Affiliation(s)
- Jolanta Flieger
- Department of Analytical Chemistry, Medical University of Lublin, Chodźki 4A, 20-093 Lublin, Poland
| | - Wojciech Franus
- Department of Geotechnics, Civil Engineering and Architecture Faculty, Lublin University of Technology, Nadbystrzycka 40, 20-618 Lublin, Poland; (W.F.); (R.P.)
| | - Rafał Panek
- Department of Geotechnics, Civil Engineering and Architecture Faculty, Lublin University of Technology, Nadbystrzycka 40, 20-618 Lublin, Poland; (W.F.); (R.P.)
| | | | - Wojciech Flieger
- Chair and Department of Anatomy, Medical University of Lublin, 20-090 Lublin, Poland;
| | - Michał Flieger
- Faculty of Medicine, Medical University of Lublin, 20-090 Lublin, Poland;
| | - Przemysław Kołodziej
- Department of Biology and Genetics, Medical University of Lublin, Chodźki 4A, 20-093 Lublin, Poland;
| |
Collapse
|
10
|
Noviana E, Ozer T, Carrell CS, Link JS, McMahon C, Jang I, Henry CS. Microfluidic Paper-Based Analytical Devices: From Design to Applications. Chem Rev 2021; 121:11835-11885. [DOI: 10.1021/acs.chemrev.0c01335] [Citation(s) in RCA: 91] [Impact Index Per Article: 30.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Eka Noviana
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Universitas Gadjah Mada, Yogyakarta, Indonesia 55281
| | - Tugba Ozer
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
- Department of Bioengineering, Faculty of Chemical and Metallurgical Engineering, Yildiz Technical University, Istanbul, Turkey 34220
| | - Cody S. Carrell
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Jeremy S. Link
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Catherine McMahon
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Ilhoon Jang
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
- Institute of Nano Science and Technology, Hanyang University, Seoul, South Korea 04763
| | - Charles S. Henry
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| |
Collapse
|
11
|
Khachornsakkul K, Hung KH, Chang JJ, Dungchai W, Chen CH. A rapid and highly sensitive paper-based colorimetric device for the on-site screening of ammonia gas. Analyst 2021; 146:2919-2927. [PMID: 33729239 DOI: 10.1039/d1an00032b] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A rapid and highly sensitive paper-based colorimetric device for the on-site detection of ammonia (NH3) gas is presented in this study. The detection principle of this device is based upon a change of color from red to yellow on a paper that has been immobilized with a pH indicator, i.e., methyl orange (pKa = 3.4), in the presence of NH3 gas. The color signal of the device can be measured through the hue channel of an HSL system via the application of a smartphone. This device can detect the amount of NH3 gas within 3 min. The linear relationship between the NH3 gas concentration and the hue signal was found to be in the range from 6.0 to 54.0 ppbv with R2 = 0.9971, and the limit of detection was found to be 2.0 ppbv. In addition, this device showed remarkably high selectivity to NH3 gas amongst the other common volatile organic compounds and general gases that are present in environmental air without the assistance of any membrane material. Furthermore, we demonstrated the applicability of this device for the detection of total NH3 gas at a chicken farm and in a laboratory, with relative standard deviations of 6.2% and 5.4%, respectively. The developed NH3 gas device in the study is easy to operate and cost-effective, with the reduction of a large consumption of chemical reagents; also, its signals can be measured simply and then recorded through a smartphone. It is suitable for the application of routine on-site detection of NH3 gas, especially concerning regions which have limited resources.
Collapse
Affiliation(s)
- Kawin Khachornsakkul
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok, 10140, Thailand.
| | - Kuen-Hau Hung
- Department of Chemistry, Tamkang University, New Taipei City 25137, Taiwan.
| | - Jung-Jung Chang
- Department of Chemistry, Tamkang University, New Taipei City 25137, Taiwan.
| | - Wijitar Dungchai
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok, 10140, Thailand.
| | - Chih-Hsin Chen
- Department of Chemistry, Tamkang University, New Taipei City 25137, Taiwan.
| |
Collapse
|
12
|
Zhang D, Li C, Ji D, Wang Y. Paper-Based Microfluidic Sensors for Onsite Environmental Detection: A Critical Review. Crit Rev Anal Chem 2021; 52:1432-1449. [PMID: 33660571 DOI: 10.1080/10408347.2021.1886900] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
A newly developed research topic, fabricated paper-based microfluidic sensors, was discussed in the field of low-cost environmental detection. Distinguished with the traditional dipstick or lateral-flow setups, these paper-based microfluidic sensors can serve as a tool for onsite quantitative and semi-quantitative measurements, without risks to cause environmental pollution. They have attracted increasing interest since the first easy-fabricated paper-based setup reported by Whitesides group in 2007. Most of the publications utilized paper-based sensors in clinical detection. In recent years, some groups started to use these sensors in environmental measurement, leading to precise, easy operation, low-cost, and eco-friendly methods for onsite detection. In this review, paper-based microfluidic sensors were briefly introduced, followed by literatures review and discussion for future perspectives.
Collapse
Affiliation(s)
- Daohong Zhang
- School of Environmental and Municipal Engineering, Tianjin Chengjian University, Tianjin, China.,Tianjin Key Laboratory of Aquatic Science and Technology, Tianjin Chengjian University, Tianjin, China
| | - Chaocan Li
- School of Environmental and Municipal Engineering, Tianjin Chengjian University, Tianjin, China.,Tianjin Key Laboratory of Aquatic Science and Technology, Tianjin Chengjian University, Tianjin, China
| | - Dongli Ji
- School of Environmental and Municipal Engineering, Tianjin Chengjian University, Tianjin, China.,Tianjin Key Laboratory of Aquatic Science and Technology, Tianjin Chengjian University, Tianjin, China
| | - Yufei Wang
- School of Environmental and Municipal Engineering, Tianjin Chengjian University, Tianjin, China.,Tianjin Key Laboratory of Aquatic Science and Technology, Tianjin Chengjian University, Tianjin, China
| |
Collapse
|
13
|
Tong X, Ga L, Zhao R, Ai J. Research progress on the applications of paper chips. RSC Adv 2021; 11:8793-8820. [PMID: 35423393 PMCID: PMC8695313 DOI: 10.1039/d0ra10470a] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2020] [Accepted: 01/29/2021] [Indexed: 01/12/2023] Open
Abstract
Due to the modern pursuit of the quality of life, science and technology have rapidly developed, resulting in higher requirements for various detection methods based on analytical technology. Herein, the development, fabrication, detection and application of paper-based microfluidic chips (μPAD) are summarized. We aim to provide a comprehensive understanding of paper chips, and then discuss challenges and future prospects in this field.
Collapse
Affiliation(s)
- Xin Tong
- College of Chemistry and Enviromental Science, Inner Mongolia Key Laboratory of Green Catalysis, Inner Mongolia Normal University 81 zhaowudalu Hohhot 010022 China
| | - Lu Ga
- College of Pharmacy, Inner Mongolia Medical University, Jinchuankaifaqu Hohhot 010110 China
| | - Ruiguo Zhao
- College of Chemistry and Chemical Engineering of Inner Mongolia University Hohhot 010020 China
| | - Jun Ai
- College of Chemistry and Enviromental Science, Inner Mongolia Key Laboratory of Green Catalysis, Inner Mongolia Normal University 81 zhaowudalu Hohhot 010022 China
| |
Collapse
|
14
|
Phoonsawat K, Dungchai W. Highly sensitive, selective and naked-eye detection of bromide and bromate using distance-based paper analytical device. Talanta 2020; 221:121590. [PMID: 33076125 DOI: 10.1016/j.talanta.2020.121590] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 08/24/2020] [Accepted: 08/25/2020] [Indexed: 12/18/2022]
Abstract
Bromine (Br) can usually be found as a bromide (Br‾) form contained in drinking water. Bromate (BrO3‾) formation often occurred during the ozonation process in the presence of Br‾. BrO3‾ is classified as a potential human carcinogen, so both the Br‾ and BrO3‾ concentrations must be strictly controlled before and after an ozone-based treatment procedure, respectively. This work reports on distance-based paper analytical devices (dPADs) that have been modified with silver hexagonal nanoprisms (AgNPrs) for highly sensitive and selective determination of both Br‾ and BrO3‾. The measurement of BrO3‾ is based upon its conversion to bromine vapor (Br2) when gauged with a paper-based headspace extractor (PAD-HS) that is coupled with dPADs (PAD-HS-dPADs). For Br‾ analysis, O2 plays an important role in the change from Br‾ to Br2 within an acid media. Br2 changes rapidly in water to give us HBrO which is a strong oxidizing agent of AgNPrs. Then, the oxidative reaction of the AgNPrs (pink color) within the presence of Br‾ and BrO3‾ establishes both silver bromide (AgBr) and the silver nanosphere (AgNPs, yellow color), which can then be easily observed as a change of a pink color band to a yellow color band by the naked eye. Quantification of Br‾ and BrO3‾ is then achieved by measuring the length of the yellow color band. Under the optimal conditions, the calibration curve will be linear in the range of 25 μg L-1 to 2 mg L-1, and from 0.5 to 50 μg L-1 for Br‾ and BrO3‾, respectively. The naked-eye detection limits were found to be 10 and 0.5 μg L-1 for Br‾ and BrO3‾, respectively. The proposed dPADs for the Br‾ and BrO3‾ detection exhibited an exceptional sensor performance combined with a low detection limit. They also have the benefits of ease of use, an instrument-free convenience, coupled with portability and a low-cost efficiency. Consequently, our sensing device should be applied to the low-level detection of Br‾ and BrO3‾ in real samples, including drinking water, rice, and flour.
Collapse
Affiliation(s)
- Kamonchanok Phoonsawat
- Organic Synthesis, Electrochemistry & Natural Product Research Unit, Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok, 10140, Thailand
| | - Wijitar Dungchai
- Applied Science & Engineering for Social Solution Unit, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok, Thailand.
| |
Collapse
|
15
|
Ortiz-Gomez I, Ortega-Muñoz M, Marín-Sánchez A, de Orbe-Payá I, Hernandez-Mateo F, Capitan-Vallvey LF, Santoyo-Gonzalez F, Salinas-Castillo A. A vinyl sulfone clicked carbon dot-engineered microfluidic paper-based analytical device for fluorometric determination of biothiols. Mikrochim Acta 2020; 187:421. [PMID: 32617684 DOI: 10.1007/s00604-020-04382-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Accepted: 06/10/2020] [Indexed: 12/20/2022]
Abstract
A microfluidic paper-based analytical device integrating carbon dot (CDs) is fabricated and used for a fluorometric off-on assay of biothiols. Vinyl sulfone (VS) click immobilization of carbon dots (CDs) on paper was accomplished by a one-pot simplified protocol that uses divinyl sulfone (DVS) as a homobifunctional reagent. This reagent mediated both the click oxa-Michael addition to the hydroxyl groups of cellulose and ulterior covalent grafting of the resulting VS paper to NH2-functionalized CDs by means of click aza-Michael addition. The resulting cellulose nanocomposite was used to engineer an inexpensive and robust microfluidic paper-based analytical device (μPAD) that is used for a reaction-based off-on fluorometric assay of biothiols (GSH, Cys, and Hcy). The intrinsic blue fluorescence of CDs (with excitation/emission maxima at 365/450 nm) is turned off via the heavy atom effect of an introduced iodo group. Fluorescence is turned on again due to the displacement of iodine by reaction with a biothiol. The increase in fluorescence is related to the concentration over a wide range (1 to 200 μM for GSH and 5-200 μM for Cys and Hcy, respectively), and the assay exhibits a low detection limit (0.3 μM for GSH and Cys and 0.4 μM for Hcy). The method allows for rapid screening and can also be used in combination with a digital camera readout. Graphical abstract Schematic representation of a μPAD based on click immobilized carbon dots and used for a reaction-based fluorometric off-on assay of biothiols. The intrinsic blue fluorescence of carbon dots is turned off via the heavy atom effect of an introduced iodo group and turned on by the displacement of this atom by reaction with a biothiol.
Collapse
Affiliation(s)
- Inmaculada Ortiz-Gomez
- Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Campus Fuentenueva s/n, 18071, Granada, Spain.,Unit of Excellence in Chemistry Applied to Biomedicine and the Environment, University of Granada, 18071, Granada, Spain
| | - Mariano Ortega-Muñoz
- Unit of Excellence in Chemistry Applied to Biomedicine and the Environment, University of Granada, 18071, Granada, Spain.,Department of Organic Chemistry, Biotechnology Institute, Faculty of Sciences, University of Granada, Campus Fuentenueva s/n, 18071, Granada, Spain
| | - Antonio Marín-Sánchez
- Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Campus Fuentenueva s/n, 18071, Granada, Spain.,Unit of Excellence in Chemistry Applied to Biomedicine and the Environment, University of Granada, 18071, Granada, Spain
| | - Ignacio de Orbe-Payá
- Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Campus Fuentenueva s/n, 18071, Granada, Spain.,Unit of Excellence in Chemistry Applied to Biomedicine and the Environment, University of Granada, 18071, Granada, Spain
| | - Fernando Hernandez-Mateo
- Unit of Excellence in Chemistry Applied to Biomedicine and the Environment, University of Granada, 18071, Granada, Spain.,Department of Organic Chemistry, Biotechnology Institute, Faculty of Sciences, University of Granada, Campus Fuentenueva s/n, 18071, Granada, Spain
| | - Luis Fermin Capitan-Vallvey
- Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Campus Fuentenueva s/n, 18071, Granada, Spain.,Unit of Excellence in Chemistry Applied to Biomedicine and the Environment, University of Granada, 18071, Granada, Spain
| | - Francisco Santoyo-Gonzalez
- Unit of Excellence in Chemistry Applied to Biomedicine and the Environment, University of Granada, 18071, Granada, Spain.,Department of Organic Chemistry, Biotechnology Institute, Faculty of Sciences, University of Granada, Campus Fuentenueva s/n, 18071, Granada, Spain
| | - Alfonso Salinas-Castillo
- Department of Analytical Chemistry, Faculty of Sciences, University of Granada, Campus Fuentenueva s/n, 18071, Granada, Spain. .,Unit of Excellence in Chemistry Applied to Biomedicine and the Environment, University of Granada, 18071, Granada, Spain.
| |
Collapse
|
16
|
Xie MR, Cai Y, Liu YQ, Wu ZY. Sensitive colorimetric detection of Pb 2+ by geometric field amplification and surface plasmon resonance visualization. Talanta 2020; 212:120749. [PMID: 32113532 DOI: 10.1016/j.talanta.2020.120749] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Revised: 01/13/2020] [Accepted: 01/14/2020] [Indexed: 11/15/2022]
Abstract
Pb2+ is one of the major environmental pollutants, which can be visually detected by surface plasmon resonance of nanoparticles. Paper based analytical device, as a newly developed microfluidic detection platform, is featured in cost-effective and suitable for on-site analysis. In this paper, a sensitive and portable detection method for Pb2+ was proposed, in which Pb2+ was electrokinetically stacked on the paper fluidic channel by geometric field amplification effect and visualized online by glutathione-modified silver nanoparticles. Colorimetric quantification of the visualized stacking band was conducted by smart phone camera. To avoid unfavorable influence from pH change on the surface plasmon resonance visualization, field amplification effect was introduced by geometric design of the paper fluidic channel. The enriched Pb2+ was clearly visible on the paper substrate, and the stacking band intensity was about four orders of magnitude enhanced, comparing to the intensity without stacking. A linear response to Pb2+ was observed in the range of 0.3-7.0 μM (R2 = 0.997) with a limit of detection of 86 nM and a limit of quantity of 0.28 μM. The established method was used in the detection of Pb2+ from river and lake water samples, and the results were confirmed by atomic absorption spectroscopy method.
Collapse
Affiliation(s)
- Mao-Rong Xie
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China
| | - Yu Cai
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China
| | - Yu-Qi Liu
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China
| | - Zhi-Yong Wu
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China.
| |
Collapse
|
17
|
Chailapakul O, Siangproh W, Jampasa S, Chaiyo S, Teengam P, Yakoh A, Pinyorospathum C. Paper-based sensors for the application of biological compound detection. COMPREHENSIVE ANALYTICAL CHEMISTRY 2020. [PMCID: PMC7274129 DOI: 10.1016/bs.coac.2020.03.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
This chapter describes the importance of PADs for biomarker detection. The screening of disease markers and other biomolecules that related to health conditions have play important roles for an indication of the risk from infections and other diseases. Paper-based analytical devices (PADs) is an excellent option for applications of biomarker detection because it contains all advantages which arise from the paper material. Moreover, the uncomplicated techniques including electrochemistry and colorimetry can be easily applied on PADs for the analytical detection. The detection method can be categorized into three main topics: enzymatic methods, immunoassays, and DNA sensors. Following the main context, other interesting applications also present in this chapter.
Collapse
|
18
|
Kalish B, Zhang J, Edema H, Luong J, Roper J, Beaudette C, Echodu R, Tsutsui H. Distance and Microsphere Aggregation-Based DNA Detection in a Paper-Based Microfluidic Device. SLAS Technol 2019; 25:58-66. [PMID: 31722603 PMCID: PMC6974776 DOI: 10.1177/2472630319887680] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
In paper-based microfluidics, the simplest devices are colorimetric, giving
qualitative results. However, getting quantitative data can be quite a bit more
difficult. Distance-based devices provide a user-friendly means of obtaining
quantitative data without the need for any additional equipment, simply by using
an included ruler or calibrated markings. This article details the development
of a quantitative DNA detection device that utilizes the aggregation of
polystyrene microspheres to affect the distance that microspheres wick through
filter paper. The microspheres are conjugated to single-stranded DNA (ssDNA)
oligomers that are partially complementary to a target strand and, in the
presence of the target strand, form a three-strand complex, resulting in the
formation of aggregates. The higher the concentration of the target strand, the
larger the aggregate, and the shorter the distance wicked by the microspheres.
This behavior was investigated across a wide range of target concentrations and
under different incubation times to understand aggregate formation. The device
was then used to successfully detect a target strand spiked in extracted plant
DNA.
Collapse
Affiliation(s)
- Brent Kalish
- Department of Mechanical Engineering, University of California Riverside, Riverside, CA, USA
| | - Jianhou Zhang
- Department of Mechanical Engineering, University of California Riverside, Riverside, CA, USA
| | - Hilary Edema
- Gulu University Bioscience Research Laboratories, Gulu, Uganda
| | - James Luong
- Department of Mechanical Engineering, University of California Riverside, Riverside, CA, USA
| | - Jenna Roper
- Department of Bioengineering, University of California Riverside, Riverside, CA, USA
| | - Chad Beaudette
- Department of Mechanical Engineering, University of California Riverside, Riverside, CA, USA
| | - Richard Echodu
- Gulu University Bioscience Research Laboratories, Gulu, Uganda.,Department of Biology, Faculty of Science, Gulu University, Gulu, Uganda
| | - Hideaki Tsutsui
- Department of Mechanical Engineering, University of California Riverside, Riverside, CA, USA.,Department of Bioengineering, University of California Riverside, Riverside, CA, USA
| |
Collapse
|
19
|
Kudo H, Maejima K, Hiruta Y, Citterio D. Microfluidic Paper-Based Analytical Devices for Colorimetric Detection of Lactoferrin. SLAS Technol 2019; 25:47-57. [DOI: 10.1177/2472630319884031] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Lactoferrin is an abundant glycoprotein in human body fluids and is known as a biomarker for various diseases. Therefore, point-of-care testing (POCT) for lactoferrin is of interest. Microfluidic paper-based analytical devices (µPADs) have gained a lot of attention as next-generation POCT device candidates, due to their inexpensiveness, operational simplicity, and being safely disposable. This work presents a colorimetric sensing approach for quantitative lactoferrin analysis. The detection mechanism takes advantage of the high affinity of lactoferrin to ferric ions (Fe3+). Lactoferrin is able to displace an indicator from a colorimetric 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP)-Fe3+ complex, resulting in a color change. A 5-Br-PADAP-Fe3+ complex was encapsulated into water-dispersible poly(styrene- block-vinylpyrrolidone) particles, whose physical entrapment in the cellulosic fiber network results in the immobilization of the complex to the paper matrix. The complex-encapsulating particles showed a color change response in accordance with lactoferrin concentration. Both color intensity-based paper well plates and distance readout-based µPADs are demonstrated. Color intensity-based devices allowed quantitative analysis of lactoferrin concentrations with a limit of detection of 110 µg/mL, using a smartphone and a color readout app. On the other hand, distance readout-based µPADs showed changes of the length of colored sections in accordance with lactoferrin concentration. In summary, we successfully developed both colorimetric intensity-based paper wells and distance-based µPADs for lactoferrin detection. This work demonstrates a user-friendly colorimetric analysis platform for lactoferrin without requiring lab equipment and expensive antibodies.
Collapse
Affiliation(s)
- Hiroko Kudo
- Department of Applied Chemistry, Keio University, Yokohama, Kanagawa, Japan
| | - Kento Maejima
- Department of Applied Chemistry, Keio University, Yokohama, Kanagawa, Japan
| | - Yuki Hiruta
- Department of Applied Chemistry, Keio University, Yokohama, Kanagawa, Japan
| | - Daniel Citterio
- Department of Applied Chemistry, Keio University, Yokohama, Kanagawa, Japan
| |
Collapse
|
20
|
Suntornsuk W, Suntornsuk L. Recent applications of paper‐based point‐of‐care devices for biomarker detection. Electrophoresis 2019; 41:287-305. [DOI: 10.1002/elps.201900258] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2019] [Revised: 09/30/2019] [Accepted: 10/05/2019] [Indexed: 12/12/2022]
Affiliation(s)
- Worapot Suntornsuk
- Department of Microbiology, Faculty of ScienceKing Mongkut's University of Technology Thonburi Bangkok Thailand
| | - Leena Suntornsuk
- Department of Pharmaceutical ChemistryFaculty of PharmacyMahidol University Bangkok Thailand
| |
Collapse
|
21
|
Boonpoempoon T, Wonsawat W, Kaneta T. Long-term stabilization of hydrogen peroxide by poly(vinyl alcohol) on paper-based analytical devices. Sci Rep 2019; 9:12951. [PMID: 31506489 PMCID: PMC6736875 DOI: 10.1038/s41598-019-49393-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2019] [Accepted: 08/23/2019] [Indexed: 11/29/2022] Open
Abstract
Stabilizing reagents that can be deposited onto paper is an important issue for researchers who depend on paper-based analytical devices (PADs), because long-term stability of the devices is essential in point-of-care testing. Here, we found that poly(vinyl alcohol) (PVA) would stabilize hydrogen peroxide placed on a paper substrate following exposure to air. Horseradish peroxidase was employed as a sample in colorimetric measurements of PADs after hydrogen peroxide and 3,3',5,5'-tetramethylbenzidine were deposited as substrates in an enzymatic reaction. The addition of PVA to hydrogen peroxide significantly suppressed its degradation. Concentrations of PVA that ranged from 0.5 to 2%, increased the duration of the stability of hydrogen peroxide, and the results for a PVA concentration of 1% approximated those of 2% PVA. Storage of the PADs at 4 °C in a refrigerator extended the stability of the hydrogen peroxide containing 2% PVA by as much as 30 days. The stability of hydrogen peroxide without PVA was degraded after one day under room temperature.
Collapse
Affiliation(s)
- Tuchpongpuch Boonpoempoon
- Department of Chemistry, Faculty of Science and Technology, Suan Sunandha Rajabhat University, Bangkok, Thailand
| | - Wanida Wonsawat
- Department of Chemistry, Faculty of Science and Technology, Suan Sunandha Rajabhat University, Bangkok, Thailand
| | - Takashi Kaneta
- Department of Chemistry, Graduate School of Natural Science and Technology, Okayama University, Okayama, Japan.
| |
Collapse
|
22
|
Distance-Based Paper Device Combined with Headspace Extraction for Determination of Cyanide. SENSORS 2019; 19:s19102340. [PMID: 31117244 PMCID: PMC6566168 DOI: 10.3390/s19102340] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/22/2019] [Revised: 05/12/2019] [Accepted: 05/17/2019] [Indexed: 12/12/2022]
Abstract
We report for the first time a distance-based paper device based on gold/silver core shell nanoparticles (Au@Ag NPs) for a simple, inexpensive, instrument-free, and portable determination of cyanide by the naked eye. Au@Ag NPs immobilized on a paper channel were etched by cyanide ions so that a yellow color band length of Au@Ag NPs is proportional to a decrease in the cyanide concentration. Quantification is achieved by measuring color length, thus eliminating the need to differentiate hues and intensities by the user, and the processing data of each imaging device. Moreover, the paper-based headspace extraction was combined with the distance-based paper device to improve the sensitivity. The enrichment factor was found to be 30-fold and the linearity was found in the range 0.05–1 mg L−1. The naked eye detection limit was 10 μg L−1 where the World Health Organization (WHO) have regulated the maximum level of cyanide in drinking water as 70 μg L−1. Our proposed device also showed no interference from common cations and anions presenting in seawater and waste water including thiocyanate, chloride. Finally, our device has been successfully applied to determine cyanide ions in seawater, drinking water, tap water and wastewater providing satisfactory precision and accuracy.
Collapse
|
23
|
Phoonsawat K, Ratnarathorn N, Henry CS, Dungchai W. A distance-based paper sensor for the determination of chloride ions using silver nanoparticles. Analyst 2018; 143:3867-3873. [PMID: 30010167 DOI: 10.1039/c8an00670a] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
We report for the first time the development of a distance-based paper sensor for a simple, inexpensive, instrument-free, and portable determination of chloride ions. Our analysis reaction is based on the oxidative etching of silver nanoparticles (AgNPs) to form AgCl in the presence of Cl- and H2O2. H2O2 reacts with AgNPs in the channel of the paper device and Cl- in the sample forming a white precipitate (AgCl) where the white color band length is proportional to the Cl- concentration. Quantification of Cl- is achieved by measuring the length of the white color band using a ruler printed on the side of the channel. Under optimal conditions, the distance-based paper sensor was characterized by a working range of 25-1000 mg L-1 (R2 = 0.9954) and the naked eye detection limit (LOD) was 2 mg L-1 (0.08 μg). Our sensor was found to be reproducible with a relative standard deviation of less than 4.51% (n = 10). The levels of Cl- in real water samples measured using our proposed device were within the error of the values measured using traditional tests but without the need for any external instrumentation. Therefore, our proposed method presents acceptable accuracy, precision, and high selectivity for point of need monitoring of Cl- in real water samples.
Collapse
Affiliation(s)
- Kamonchanok Phoonsawat
- Organic Synthesis, Electrochemistry & Natural Product Research Unit, Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Prachautid Road, Thungkru, Bangkok, 10140, Thailand.
| | | | | | | |
Collapse
|
24
|
Ghasemi A, Rabiee N, Ahmadi S, Hashemzadeh S, Lolasi F, Bozorgomid M, Kalbasi A, Nasseri B, Shiralizadeh Dezfuli A, Aref AR, Karimi M, Hamblin MR. Optical assays based on colloidal inorganic nanoparticles. Analyst 2018; 143:3249-3283. [PMID: 29924108 PMCID: PMC6042520 DOI: 10.1039/c8an00731d] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Colloidal inorganic nanoparticles have wide applications in the detection of analytes and in biological assays. A large number of these assays rely on the ability of gold nanoparticles (AuNPs, in the 20 nm diameter size range) to undergo a color change from red to blue upon aggregation. AuNP assays can be based on cross-linking, non-cross linking or unmodified charge-based aggregation. Nucleic acid-based probes, monoclonal antibodies, and molecular-affinity agents can be attached by covalent or non-covalent means. Surface plasmon resonance and SERS techniques can be utilized. Silver NPs also have attractive optical properties (higher extinction coefficient). Combinations of AuNPs and AgNPs in nanocomposites can have additional advantages. Magnetic NPs and ZnO, TiO2 and ZnS as well as insulator NPs including SiO2 can be employed in colorimetric assays, and some can act as peroxidase mimics in catalytic applications. This review covers the synthesis and stabilization of inorganic NPs and their diverse applications in colorimetric and optical assays for analytes related to environmental contamination (metal ions and pesticides), and for early diagnosis and monitoring of diseases, using medically important biomarkers.
Collapse
Affiliation(s)
- Amir Ghasemi
- Department of Materials Science and Engineering, Sharif University of Technology, Tehran, Iran and Advances Nanobiotechnology and Nanomedicine Research Group (ANNRG), Iran University of Medical Sciences, Tehran, Iran
| | - Navid Rabiee
- Department of Chemistry, Shahid Beheshti University, Tehran, Iran
| | - Sepideh Ahmadi
- Advances Nanobiotechnology and Nanomedicine Research Group (ANNRG), Iran University of Medical Sciences, Tehran, Iran and Department of Biology, Faculty of Basic Sciences, University of Zabol, Zabol, Iran
| | - Shabnam Hashemzadeh
- Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran and Research Center for Pharmaceutical Nanotechnology, Biomedicine Institute, Tabriz University of Medical Science, Tabriz, Iran
| | - Farshad Lolasi
- Department of Biotechnology, Faculty of Advanced Sciences and Technologies, University of Isfahan, Isfahan, 81746-73441, Iran and Department of Agronomy and Plant Breeding, College of Agriculture, Isfahan University of Technology, Isfahan, Iran
| | - Mahnaz Bozorgomid
- Department of Pharmaceutical Chemistry, Islamic Azad University of Pharmaceutical Sciences Branch, Tehran, Iran
| | - Alireza Kalbasi
- Department of Medical Oncology, Dana-Farber Cancer Institute, Boston, MA, USA
| | - Behzad Nasseri
- Departments of Microbiology and Microbial Biotechnology and Nanobiotechnology, Faculty of Life Sciences and Biotechnology, Shahid Beheshti University, Tehran, Iran and Chemical Engineering Deptartment and Bioengineeing Division, Hacettepe University, 06800, Beytepe, Ankara, Turkey
| | - Amin Shiralizadeh Dezfuli
- Advances Nanobiotechnology and Nanomedicine Research Group (ANNRG), Iran University of Medical Sciences, Tehran, Iran and Department of Medical Nanotechnology, Faculty of Advanced Technologies in Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Amir Reza Aref
- Belfer Center for Applied Cancer Science, Dana-Farber Cancer Institute, Harvard Medical School, Boston, MA, USA
| | - Mahdi Karimi
- Cellular and Molecular Research Center, Iran University of Medical Sciences, Tehran, Iran. and Department of Medical Nanotechnology, Faculty of Advanced Technologies in Medicine, Iran University of Medical Sciences, Tehran, Iran and Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA.
| | - Michael R Hamblin
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA. and Department of Dermatology, Harvard Medical School, Boston, MA 02115, USA and Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA 02139, USA
| |
Collapse
|
25
|
Ammanath G, Yildiz UH, Palaniappan A, Liedberg B. Luminescent Device for the Detection of Oxidative Stress Biomarkers in Artificial Urine. ACS APPLIED MATERIALS & INTERFACES 2018; 10:7730-7736. [PMID: 29430928 DOI: 10.1021/acsami.7b17252] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
A luminescent paper-based device for the visual detection of oxidative stress biomarkers is reported. The device consists of a polyvinylidene fluoride membrane impregnated with poly(3-alkoxy-4-methylthiophene) (PT) for colorimetric detection. 8-hydroxy-2'-deoxyguanosine (8-OHdG), a biomarker associated with oxidative stress, is used as a model system for validating the proposed methodology. The detection strategy is based on monitoring the changes in optical properties of PT associated with its conformational changes upon interaction with an aptamer in the presence and in the absence of 8-OHdG. Fluorometric and colorimetric monitoring revealed linear responses for 8-OHdG concentrations between 50 pM and 500 nM (∼14 pg/mL to 140 ng/mL), with limits of detection of ∼300 pM and ∼350 pM, respectively for ( n = 3). Colorimetric responses in artificial urine ascertained rapid, sensitive, and selective detection of 8-OHdG at clinically relevant (pM to nM) concentration levels. Furthermore, the proposed methodology enables point-of-care diagnostics for oxidative stress without requiring sophisticated instrumentation.
Collapse
Affiliation(s)
- Gopal Ammanath
- Centre for Biomimetic Sensor Science , Nanyang Technological University , Singapore 637553
- Nanyang Institute of Technology in Health and Medicine, Interdisciplinary Graduate School , Nanyang Technological University , Singapore 637553
- School of Materials Science and Engineering , Nanyang Technological University , Singapore 639798
| | - Umit Hakan Yildiz
- Department of Chemistry , Izmir Institute of Technology , Urla, 35430 Izmir , Turkey
| | - Alagappan Palaniappan
- Centre for Biomimetic Sensor Science , Nanyang Technological University , Singapore 637553
- Nanyang Institute of Technology in Health and Medicine, Interdisciplinary Graduate School , Nanyang Technological University , Singapore 637553
| | - Bo Liedberg
- Centre for Biomimetic Sensor Science , Nanyang Technological University , Singapore 637553
- Nanyang Institute of Technology in Health and Medicine, Interdisciplinary Graduate School , Nanyang Technological University , Singapore 637553
- School of Materials Science and Engineering , Nanyang Technological University , Singapore 639798
| |
Collapse
|
26
|
Improved assessment of accuracy and performance using a rotational paper-based device for multiplexed detection of heavy metals. Talanta 2017; 178:426-431. [PMID: 29136843 DOI: 10.1016/j.talanta.2017.09.059] [Citation(s) in RCA: 67] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Revised: 09/15/2017] [Accepted: 09/17/2017] [Indexed: 01/31/2023]
Abstract
In this work, a novel rotational microfluidic paper-based device was developed to improve the accuracy and performance of the multiplexed colorimetric detection by effectively avoiding the diffusion of colorimetric reagent on the detection zone. The integrated paper-based rotational valves were used to control the connection or disconnection between detection zones and fluid channels. Based on the manipulation of the rotational valves, this rotational paper-based device could prevent the random diffusion of colorimetric reagent and reduce the error of quantitative analysis considerably. The multiplexed colorimetric detection of heavy metals Ni(II), Cu(II) and Cr(VI) were implemented on the rotational device and the detection limits could be found to be 4.8, 1.6, and 0.18mg/L, respectively. The developed rotational device showed the great advantage in improving the detection accuracy and was expected to be a low-cost, portable analytical platform for the on-site detection.
Collapse
|
27
|
Markina M, Stozhko N, Krylov V, Vidrevich M, Brainina K. Nanoparticle-based paper sensor for thiols evaluation in human skin. Talanta 2017; 165:563-569. [PMID: 28153299 DOI: 10.1016/j.talanta.2017.01.012] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2016] [Revised: 01/03/2017] [Accepted: 01/06/2017] [Indexed: 10/20/2022]
Abstract
A new sensitive non-invasive gold nanoparticle-based sensor that enables to detect thiols in the human skin has been developed. The detection procedure implied the assessment of the color change of a paper sensor resulting from aggregation of gold nanoparticles caused by thiols. The ratio of the intensity of the photo image blue channel vs the red one (in units of RGB coloration) served as analytical response. The main thiol in the skin is glutathione, therefore, it was used as model biothiol and spiking substance. The range of linearity for glutathione was 8-75µM, the detection limit was 6.9µM. RSD≤7% is for inter-day determination of 10μM glutathione and RSD≤12% is the intra-day value. The recovery of 5µM and 10µM of glutathione was evaluated by applying solution, containing thiol-spikes, on skin. The results varied in the range 77-138%. A hundred-fold excess of serine, alanine, histidine, threonine, creatinine, urea, and ammonia; a ten-fold excess of glycine, proline, leucine, isoleucine, phenylalanine, asparagine; and a five-fold excess of valine, tryptophan, tyrosine, and uric acid, which can be extracted from the skin and is contained in the test matrix, have no significant effect on 10µM glutathione signal. Thiols level in the skin of volunteers (21-65 years old, men and women) detected with the use of a proposed non-invasive sensor was 11.6-47.5µM.
Collapse
Affiliation(s)
- M Markina
- Ural State University of Economics, 8 March St., 62, Ekaterinburg 620144, Russian Federation
| | - N Stozhko
- Ural State University of Economics, 8 March St., 62, Ekaterinburg 620144, Russian Federation
| | - V Krylov
- Ural State University of Economics, 8 March St., 62, Ekaterinburg 620144, Russian Federation
| | - M Vidrevich
- Ural State University of Economics, 8 March St., 62, Ekaterinburg 620144, Russian Federation
| | - Kh Brainina
- Ural State University of Economics, 8 March St., 62, Ekaterinburg 620144, Russian Federation; Ural Federal University, Lenin Ave., 51, Ekaterinburg 620000, Russian Federation.
| |
Collapse
|
28
|
Cunningham JC, DeGregory PR, Crooks RM. New Functionalities for Paper-Based Sensors Lead to Simplified User Operation, Lower Limits of Detection, and New Applications. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2016; 9:183-202. [PMID: 27049635 DOI: 10.1146/annurev-anchem-071015-041605] [Citation(s) in RCA: 56] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
In the last decade, paper analytical devices (PADs) have evolved into sophisticated yet simple sensors with biological and environmental applications in the developed and developing world. The focus of this review is the technological improvements that have over the past five years increased the applicability of PADs to real-world problems. Specifically, this review reports on advances in sample processing, fluid flow control, signal amplification, and component integration. Throughout, we have sought to emphasize advances that retain the main virtues of PADs: low cost, portability, and simplicity.
Collapse
Affiliation(s)
| | - Paul R DeGregory
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712-1224;
| | - Richard M Crooks
- Department of Chemistry, The University of Texas at Austin, Austin, Texas 78712-1224;
| |
Collapse
|
29
|
Tian T, Li J, Song Y, Zhou L, Zhu Z, Yang CJ. Distance-based microfluidic quantitative detection methods for point-of-care testing. LAB ON A CHIP 2016; 16:1139-1151. [PMID: 26928571 DOI: 10.1039/c5lc01562f] [Citation(s) in RCA: 106] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Equipment-free devices with quantitative readout are of great significance to point-of-care testing (POCT), which provides real-time readout to users and is especially important in low-resource settings. Among various equipment-free approaches, distance-based visual quantitative detection methods rely on reading the visual signal length for corresponding target concentrations, thus eliminating the need for sophisticated instruments. The distance-based methods are low-cost, user-friendly and can be integrated into portable analytical devices. Moreover, such methods enable quantitative detection of various targets by the naked eye. In this review, we first introduce the concept and history of distance-based visual quantitative detection methods. Then, we summarize the main methods for translation of molecular signals to distance-based readout and discuss different microfluidic platforms (glass, PDMS, paper and thread) in terms of applications in biomedical diagnostics, food safety monitoring, and environmental analysis. Finally, the potential and future perspectives are discussed.
Collapse
Affiliation(s)
- Tian Tian
- MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Jiuxing Li
- MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Yanling Song
- MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Leiji Zhou
- MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Zhi Zhu
- MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Chaoyong James Yang
- MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| |
Collapse
|
30
|
Meredith NA, Quinn C, Cate DM, Reilly TH, Volckens J, Henry CS. Paper-based analytical devices for environmental analysis. Analyst 2016; 141:1874-87. [PMID: 26901771 PMCID: PMC9423764 DOI: 10.1039/c5an02572a] [Citation(s) in RCA: 170] [Impact Index Per Article: 21.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/29/2023]
Abstract
The field of paper-based microfluidics has experienced rapid growth over the past decade. Microfluidic paper-based analytical devices (μPADs), originally developed for point-of-care medical diagnostics in resource-limited settings, are now being applied in new areas, such as environmental analyses. Low-cost paper sensors show great promise for on-site environmental analysis; the theme of ongoing research complements existing instrumental techniques by providing high spatial and temporal resolution for environmental monitoring. This review highlights recent applications of μPADs for environmental analysis along with technical advances that may enable μPADs to be more widely implemented in field testing.
Collapse
Affiliation(s)
- Nathan A Meredith
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA.
| | - Casey Quinn
- Department of Environmental and Radiological Health Sciences, Colorado State University, Fort Collins, Colorado 80523, USA.
| | - David M Cate
- Department of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, USA and Intellectual Ventures, Bellevue, Washington 98007, USA
| | - Thomas H Reilly
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA. and Access Sensor Technologies, LLC, Fort Collins, Colorado 80524, USA
| | - John Volckens
- Department of Environmental and Radiological Health Sciences, Colorado State University, Fort Collins, Colorado 80523, USA. and Department of Mechanical Engineering, Colorado State University, Fort Collins, Colorado 80523, USA
| | - Charles S Henry
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA. and Department of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, USA and Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523, USA
| |
Collapse
|
31
|
Abstract
Airborne particles have been associated with a range of adverse cardiopulmonary outcomes, which has driven its monitoring at stationary central sites throughout the world. Individual exposures, however, can differ substantially from concentrations measured at central sites due to spatial variability across a region and sources unique to the individual, such as cooking or cleaning in homes, traffic emissions during commutes, and widely varying sources encountered at work. Personal monitoring with small, battery-powered instruments enables the measurement of an individual's exposure as they go about their daily activities. Personal monitoring can substantially reduce exposure misclassification and improve the power to detect relationships between particulate pollution and adverse health outcomes. By partitioning exposures to known locations and sources, it may be possible to account for variable toxicity of different sources. This review outlines recent advances in the field of personal exposure assessment for particulate pollution. Advances in battery technology have improved the feasibility of 24-h monitoring, providing the ability to more completely attribute exposures to microenvironment (e.g., work, home, commute). New metrics to evaluate the relationship between particulate matter and health are also being considered, including particle number concentration, particle composition measures, and particle oxidative load. Such metrics provide opportunities to develop more precise associations between airborne particles and health and may provide opportunities for more effective regulations.
Collapse
Affiliation(s)
- Kirsten A Koehler
- Department of Environmental Health Science, Johns Hopkins University, 601 N Wolfe St, Baltimore, MD, 21205, USA.
| | - Thomas M Peters
- Department of Occupational and Environmental Health, University of Iowa, 145 N Riverside Dr, Iowa City, IA, 52242, USA.
| |
Collapse
|
32
|
Yamada K, Henares TG, Suzuki K, Citterio D. Distance-Based Tear Lactoferrin Assay on Microfluidic Paper Device Using Interfacial Interactions on Surface-Modified Cellulose. ACS APPLIED MATERIALS & INTERFACES 2015; 7:24864-75. [PMID: 26488371 DOI: 10.1021/acsami.5b08124] [Citation(s) in RCA: 78] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
"Distance-based" detection motifs on microfluidic paper-based analytical devices (μPADs) allow quantitative analysis without using signal readout instruments in a similar manner to classical analogue thermometers. To realize a cost-effective and calibration-free distance-based assay of lactoferrin in human tear fluid on a μPAD not relying on antibodies or enzymes, we investigated the fluidic mobilities of the target protein and Tb(3+) cations used as the fluorescent detection reagent on surface-modified cellulosic filter papers. Chromatographic elution experiments in a tear-like sample matrix containing electrolytes and proteins revealed a collapse of attractive electrostatic interactions between lactoferrin or Tb(3+) and the cellulosic substrate, which was overcome by the modification of the paper surface with the sulfated polysaccharide ι-carrageenan. The resulting μPAD based on the fluorescence emission distance successfully analyzed 0-4 mg mL(-1) of lactoferrin in complex human tear matrix with a lower limit of detection of 0.1 mg mL(-1) by simple visual inspection. Assay results of 18 human tear samples including ocular disease patients and healthy volunteers showed good correlation to the reference ELISA method with a slope of 0.997 and a regression coefficient of 0.948. The distance-based quantitative signal and the good batch-to-batch fabrication reproducibility relying on printing methods enable quantitative analysis by simply reading out "concentration scale marks" printed on the μPAD without performing any calibration and using any signal readout instrument.
Collapse
Affiliation(s)
- Kentaro Yamada
- Department of Applied Chemistry, Keio University , 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan
| | - Terence G Henares
- Department of Applied Chemistry, Keio University , 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan
| | - Koji Suzuki
- Department of Applied Chemistry, Keio University , 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan
| | - Daniel Citterio
- Department of Applied Chemistry, Keio University , 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan
| |
Collapse
|
33
|
Alkasir RSJ, Rossner A, Andreescu S. Portable Colorimetric Paper-Based Biosensing Device for the Assessment of Bisphenol A in Indoor Dust. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2015; 49:9889-9897. [PMID: 26180900 DOI: 10.1021/acs.est.5b01588] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Bisphenol A (BPA) is found in polycarbonate plastic and epoxy resins and is used in a variety of commercial and consumer products. The leaching of BPA can result in human exposure via inhalation, ingestion, and dermal routes. As a result, humans have been exposed in their home and work environment to BPA. Conventional methods for BPA exposure assessment rely on cumbersome laboratory instrumentation with high capital and operational expenditures which limit the number of samples that can be analyzed. We report here the design of a compact portable colorimetric paper-based biosensing device with integrated sampling/analysis units for field-based measurements of BPA in indoor dust. The system employs interchangeable low-cost paper-based enzyme sensors as a test zone for BPA detection interfaced with an air-sampling cassette as a sample collection area. The sensor response was concentration-dependent with a detection limit of 0.28 μg/g. The sensor was validated with the conventional gas chromatography method and used to detect BPA exposure in household dust. BPA concentrations ranged from 0.05 to 3.87 μg/g in 57 household dust samples when both methods were used. The potential of this method for field measurements of dust samples is discussed.
Collapse
Affiliation(s)
- Ramiz S J Alkasir
- †Department of Chemistry and Bimolecular Science, Clarkson University, Potsdam, New York 13699-5810, United States
| | - Alan Rossner
- ‡Institute for a Sustainable Environment, Clarkson University, Potsdam, New York 13699-5715, United States
| | - Silvana Andreescu
- †Department of Chemistry and Bimolecular Science, Clarkson University, Potsdam, New York 13699-5810, United States
| |
Collapse
|
34
|
Cate DM, Noblitt SD, Volckens J, Henry CS. Multiplexed paper analytical device for quantification of metals using distance-based detection. LAB ON A CHIP 2015; 15:2808-18. [PMID: 26009988 PMCID: PMC4470859 DOI: 10.1039/c5lc00364d] [Citation(s) in RCA: 151] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Exposure to metal-containing aerosols has been linked with adverse health outcomes for almost every organ in the human body. Commercially available techniques for quantifying particulate metals are time-intensive, laborious, and expensive; often sample analysis exceeds $100. We report a simple technique, based upon a distance-based detection motif, for quantifying metal concentrations of Ni, Cu, and Fe in airborne particulate matter using microfluidic paper-based analytical devices. Paper substrates are used to create sensors that are self-contained, self-timing, and require only a drop of sample for operation. Unlike other colorimetric approaches in paper microfluidics that rely on optical instrumentation for analysis, with distance-based detection, analyte is quantified visually based on the distance of a colorimetric reaction, similar to reading temperature on a thermometer. To demonstrate the effectiveness of this approach, Ni, Cu, and Fe were measured individually in single-channel devices; detection limits as low as 0.1, 0.1, and 0.05 μg were reported for Ni, Cu, and Fe. Multiplexed analysis of all three metals was achieved with detection limits of 1, 5, and 1 μg for Ni, Cu, and Fe. We also extended the dynamic range for multi-analyte detection by printing concentration gradients of colorimetric reagents using an off-the-shelf inkjet printer. Analyte selectivity was demonstrated for common interferences. To demonstrate utility of the method, Ni, Cu, and Fe were measured from samples of certified welding fume; levels measured with paper sensors matched known values determined gravimetrically.
Collapse
Affiliation(s)
- David M. Cate
- School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, USA
| | - Scott D. Noblitt
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA
| | - John Volckens
- School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, USA
- Department of Mechanical Engineering, Colorado State University, Fort Collins, Colorado 80523, USA
| | - Charles S. Henry
- School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, USA
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, USA
| |
Collapse
|
35
|
Vilela D, González MC, Escarpa A. Nanoparticles as analytical tools for in-vitro antioxidant-capacity assessment and beyond. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2014.07.017] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
36
|
Cate DM, Adkins JA, Mettakoonpitak J, Henry CS. Recent Developments in Paper-Based Microfluidic Devices. Anal Chem 2014; 87:19-41. [PMID: 25375292 DOI: 10.1021/ac503968p] [Citation(s) in RCA: 709] [Impact Index Per Article: 70.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- David M. Cate
- Department
of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Jaclyn A. Adkins
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Jaruwan Mettakoonpitak
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Charles S. Henry
- Department
of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
- Department
of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| |
Collapse
|
37
|
Evans E, Gabriel EFM, Benavidez TE, Tomazelli Coltro WK, Garcia CD. Modification of microfluidic paper-based devices with silica nanoparticles. Analyst 2014; 139:5560-7. [PMID: 25204446 PMCID: PMC4180781 DOI: 10.1039/c4an01147c] [Citation(s) in RCA: 96] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
This paper describes a silica nanoparticle-modified microfluidic paper-based analytical device (μPAD) with improved color intensity and uniformity for three different enzymatic reactions with clinical relevance (lactate, glucose, and glutamate). The μPADs were produced on a Whatman grade 1 filter paper and using a CO2 laser engraver. Silica nanoparticles modified with 3-aminopropyltriethoxysilane were then added to the paper devices to facilitate the adsorption of selected enzymes and prevent the washing away effect that creates color gradients in the colorimetric measurements. According to the results herein described, the addition of silica nanoparticles yielded significant improvements in color intensity and uniformity. The resulting μPADs allowed for the detection of the three analytes in clinically relevant concentration ranges with limits of detection (LODs) of 0.63 mM, 0.50 mM, and 0.25 mM for lactate, glucose, and glutamate, respectively. An example of an analytical application has been demonstrated for the semi-quantitative detection of all three analytes in artificial urine. The results demonstrate the potential of silica nanoparticles to avoid the washing away effect and improve the color uniformity and intensity in colorimetric bioassays performed on μPADs.
Collapse
Affiliation(s)
- Elizabeth Evans
- Department of Chemistry, The University of Texas at San Antonio, San Antonio, TX 78249, USA.
| | | | | | | | | |
Collapse
|
38
|
Sameenoi Y, Nongkai PN, Nouanthavong S, Henry CS, Nacapricha D. One-step polymer screen-printing for microfluidic paper-based analytical device (μPAD) fabrication. Analyst 2014; 139:6580-8. [DOI: 10.1039/c4an01624f] [Citation(s) in RCA: 127] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
39
|
Jayawardane BM, Wongwilai W, Grudpan K, Kolev SD, Heaven MW, Nash DM, McKelvie ID. Evaluation and application of a paper-based device for the determination of reactive phosphate in soil solution. JOURNAL OF ENVIRONMENTAL QUALITY 2014; 43:1081-1085. [PMID: 25602837 DOI: 10.2134/jeq2013.08.0336] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The evaluation and validation of a new low-cost microfluidic paper-based analytical device (μPAD) for the determination of reactive phosphate in soil solution is described. This device allows up to 15 replicate measurements of reactive phosphate on one credit card-sized device and requires only a desktop or hand scanner for signal detection and quantification. The proposed method showed a linear response between 0.1 and 1.0 mg L and between 1.0 and 10.0 mg L P with a limit of detection of 0.05 mg L P. When applied to the analysis of soil solution, there was excellent agreement between results obtained using the μPAD and those obtained by a reference spectrophotometric method, as indicated by the following regression equation: [P] = (0.997 ± 0.005)[P] - (0.020 ± 0.008) ( = 0.997; = 110). It was found that the ambient temperature storage stability of the μPAD could be extended to 15 d by incorporating a removable polymeric interleaving sheet between the adjacent paper layers of the device. The observed sensitivity of the μPADs to sunlight, which was manifested by photoreduction of the chromogenic molybdate reagent used in the assay, was overcome by preparing the μPADs with an ultraviolet-filtering laminating material. The proposed method is rapid, with a reaction time of only 10 min, is easy to perform, and is suitable for application in the field.
Collapse
|
40
|
Lewis GG, Robbins JS, Phillips ST. A prototype point-of-use assay for measuring heavy metal contamination in water using time as a quantitative readout. Chem Commun (Camb) 2013; 50:5352-4. [PMID: 24275801 DOI: 10.1039/c3cc47698g] [Citation(s) in RCA: 74] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
This Communication describes a prototype quantitative paper-based assay that simultaneously measures the levels of Pb(2+) and Hg(2+) in water. The assay requires only measurements of time to yield a quantitative readout, and the results are independent of sample volume, humidity, and sample viscosity.
Collapse
Affiliation(s)
- Gregory G Lewis
- The Pennsylvania State University, 104 Chemistry Bldg., University Park, PA 16802, USA.
| | | | | |
Collapse
|