1
|
Feng T, Yan S, Wang Z, Fan X. A facile fluorescence turn-on biosensor customized for monitoring of protein kinase activity based on carboxylic carbon nanoparticles-peptide complexes. LUMINESCENCE 2022; 37:922-929. [PMID: 35322517 DOI: 10.1002/bio.4237] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 02/28/2022] [Accepted: 03/21/2022] [Indexed: 11/12/2022]
Abstract
In this study, we present a facile and low-cost approach for detecting protein kinase A (PKA) by assembling a purpose-designed carboxyfluorescein (FAM)-labeled peptide with carboxylic carbon nanoparticles (CNPs). Fluorescence of the FAM-labeled peptide gradually decreases to low background signal as a result of the electron transfer from CNPs to FAM-labeled peptide via the peptide, which acts as a bridge. The reaction in the sensor in the presence of adenosine 5'-triphosphate and PKA phosphorylates the substrate peptide and disrupts the electrostatic repulsive force between the CNPs and the peptide, thus altering the spectroscopic signal of the system. The change in fluorescence signal was directly proportional to the PKA concentration in the range of 0-1.8 U/mL with a detection limit of 0.04 U/mL. These results suggest that PKA activity can be effectively measured using the developed PKA biosensor. Moreover, the fluorescence biosensor was successfully used in the investigation of PKA in spiked human embryonic kidney (HEK) 293 cells lysates, indicating its potential applications in protein kinase-related biochemical fundamental research.
Collapse
Affiliation(s)
- Tingting Feng
- Pharmaceutical Informatics Institute, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, China.,Institute of Pharmaceutical and Food Engineering, Shanxi University of Chinese Medicine, Jinzhong, China
| | - Shuzhu Yan
- Institute of Pharmaceutical and Food Engineering, Shanxi University of Chinese Medicine, Jinzhong, China
| | - Zheng Wang
- Pharmaceutical Informatics Institute, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, China
| | - Xiaohui Fan
- Pharmaceutical Informatics Institute, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, China
| |
Collapse
|
2
|
Hou S, Feng T, Zhao N, Zhang J, Wang H, Liang N, Zhao L. A carbon nanoparticle-peptide fluorescent sensor custom-made for simple and sensitive detection of trypsin. J Pharm Anal 2020; 10:482-489. [PMID: 33133732 PMCID: PMC7591810 DOI: 10.1016/j.jpha.2020.08.009] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2020] [Revised: 08/20/2020] [Accepted: 08/20/2020] [Indexed: 01/06/2023] Open
Abstract
Herein, we report a novel sensor to detect trypsin using a purpose-designed fluorescein-labelled peptide with negatively charged carbon nanoparticles (CNPs) modified by acid oxidation. The fluorescence of the fluorescein-labelled peptide was quenched by CNPs. The sensor reacted with trypsin to cleave the peptide, resulting in the release of the dye moiety and a substantial increase in fluorescence intensity, which was dose- and time-dependent, and trypsin could be quantified accordingly. Correspondingly, the biosensor has led to the development of a convenient and efficient fluorescent method to measure trypsin activity, with a detection limit of 0.7 μg/mL. The method allows rapid determination of trypsin activity in the normal and acute pancreatitis range, suitable for point-of-care testing. Furthermore, the applicability of the method has been demonstrated by detecting trypsin in spiked urine samples.
Collapse
Affiliation(s)
- Shanshan Hou
- School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, Liaoning Province, 110016, China
| | - Tingting Feng
- Institute of Pharmaceutical and Food Engineering, Shanxi University of Chinese Medicine, Jinzhong, Shanxi Province, 030619, China
| | - Na Zhao
- School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, Liaoning Province, 110016, China
| | - Jiaxin Zhang
- School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, Liaoning Province, 110016, China
| | - Huibin Wang
- School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, Liaoning Province, 110016, China
| | - Ning Liang
- School of Pharmaceutical Engineering, Shenyang Pharmaceutical University, Shenyang, Liaoning Province, 110016, China
| | - Longshan Zhao
- School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, Liaoning Province, 110016, China
| |
Collapse
|
3
|
Zhang J, Chai X, He XP, Kim HJ, Yoon J, Tian H. Fluorogenic probes for disease-relevant enzymes. Chem Soc Rev 2019; 48:683-722. [PMID: 30520895 DOI: 10.1039/c7cs00907k] [Citation(s) in RCA: 357] [Impact Index Per Article: 71.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Traditional biochemical methods for enzyme detection are mainly based on antibody-based immunoassays, which lack the ability to monitor the spatiotemporal distribution and, in particular, the in situ activity of enzymes in live cells and in vivo. In this review, we comprehensively summarize recent progress that has been made in the development of small-molecule as well as material-based fluorogenic probes for sensitive detection of the activities of enzymes that are related to a number of human diseases. The principles utilized to design these probes as well as their applications are reviewed. Specific attention is given to fluorogenic probes that have been developed for analysis of the activities of enzymes including oxidases and reductases, those that act on biomacromolecules including DNAs, proteins/peptides/amino acids, carbohydrates and lipids, and those that are responsible for translational modifications. We envision that this review will serve as an ideal reference for practitioners as well as beginners in relevant research fields.
Collapse
Affiliation(s)
- Junji Zhang
- Key Laboratory for Advanced Materials and Joint International Research Laboratory of Precision Chemistry and Molecular Engineering, Feringa Nobel Prize Scientist Joint Research Center, School of Chemistry and Molecular Engineering, East China University of Science and Technology, 130 Meilong Rd., Shanghai 200237, P. R. China.
| | | | | | | | | | | |
Collapse
|
4
|
Tang X, Wu K, Zhao H, Chen M, Ma C. A Label-Free Fluorescent Assay for the Rapid and Sensitive Detection of Adenosine Deaminase Activity and Inhibition. SENSORS 2018; 18:s18082441. [PMID: 30060448 PMCID: PMC6111851 DOI: 10.3390/s18082441] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2018] [Revised: 07/21/2018] [Accepted: 07/26/2018] [Indexed: 11/20/2022]
Abstract
Adenosine deaminase (ADA), able to catalyze the irreversible deamination of adenosine into inosine, can be found in almost all tissues and plays an important role in several diseases. In this work, we developed a label-free fluorescence method for the detection of adenosine deaminase activity and inhibition. In the presence of ADA, ATP has been shown to be hydrolyzed. The ATP aptamer was shown to form a G-quadruplex/thioflavin T (ThT) complex with ThT and exhibited an obvious fluorescence signal. However, the ATP aptamer could bind with ATP and exhibited a low fluorescence signal because of the absence of ADA. This assay showed high sensitivity to ADA with a detection limit of 1 U/L based on an SNR of 3 and got a good linear relationship within the range of 1–100 U/L with R2 = 0.9909. The LOD is lower than ADA cutoff value (4 U/L) in the clinical requirement and more sensitive than most of the reported methods. This technique exhibited high selectivity for ADA against hoGG I, UDG, RNase H and λexo. Moreover, this strategy was successfully applied for assaying the inhibition of ADA using erythro-9-(2-hydroxy-3-nonyl) adenine (EHNA) and, as such, demonstrated great potential for the future use in the diagnosis of ADA-relevant diseases, particularly in advanced drug development.
Collapse
Affiliation(s)
- Xinxing Tang
- School of Art and Design, Changsha University of Science and Technology, Changsha 410114, China.
| | - Kefeng Wu
- School of Life Sciences, Central South University, Changsha 410013, China.
| | - Han Zhao
- School of Life Sciences, Central South University, Changsha 410013, China.
| | - Mingjian Chen
- School of Life Sciences, Central South University, Changsha 410013, China.
| | - Changbei Ma
- School of Life Sciences, Central South University, Changsha 410013, China.
| |
Collapse
|
5
|
Ultrasensitive electrochemical detection of protein tyrosine kinase-7 by gold nanoparticles and methylene blue assisted signal amplification. Biosens Bioelectron 2016; 83:39-44. [PMID: 27101533 DOI: 10.1016/j.bios.2016.04.032] [Citation(s) in RCA: 44] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2016] [Revised: 04/09/2016] [Accepted: 04/12/2016] [Indexed: 01/08/2023]
Abstract
We present here an ultrasensitive and simple strategy for protein tyrosine kinase-7 (PTK7) detection based on the recognition-induced structure change of sgc8 aptamer, and the signal change of methylene blue (MB) that interacted with sandwiched DNA complex. To construct such a sensor, an homogeneous nano-surface was formed firstly on the glass carbon electrode (GCE) by using negatively charged Nafion (Nf) as the inner layer and positively charged gold nanoparticles ((+)AuNPs) as the outer layer, followed by the immobilization of sgc8 aptamer based on Au-S bond. In the presence of helper probe (HP), sandwiched DNA complex was formed between the sgc8 aptamer and the DNA modified gold nanoparticle probe (DNA-AuNPs). Then, a strong current signal was produced due to the capture of abundant MB molecules by both the sandwiched DNA complex and the multiple DNAs that modified on AuNPs surface. However, the specific binding of sgc8 aptamer with PNK7 would trigger a structure transition of it, and directly prevented the following formation of sandwiched structure and the capture of MB. Thus, PTK7 detection could be realized based on monitoring the signal reduction of MB upon incubation of sgc8 aptamer with PTK7. Under optimal conditions, a low detection limit of 372 fM was obtained for PNK7 detection. Due to the employment of sgc8 aptamer, the proposed biosensor exhibited high selectivity to PNK7. Moreover, satisfactory results were obtained when the proposed method was applied for PNK7 detection in cellular debris.
Collapse
|
6
|
Zeng X, Wang C, Li YX, Li XX, Su YY, An J, Tang YL. Label-free aptasensor for adenosine deaminase sensing based on fluorescence turn-on. Analyst 2015; 140:1192-7. [PMID: 25521724 DOI: 10.1039/c4an01963f] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
A label-free and fluorescence turn-on aptamer biosensor has been developed for the detection of adenosine deaminase (ADA) activity with simplicity and selectivity. Adenosine aptamer will form a tight stem-loop structure upon binding with adenosine. In the absence of ADA, only a small quantity of picagreen intercalates into the stem section of aptamer, resulting in a low fluorescence of picagreen when excited at 490 nm. Interestingly, after the addition of ADA, adenosine is hydrolyzed to inosine, and the released aptamer forms double-stranded DNA (dsDNA) with its complementary single-stranded DNAc, followed by the intercalation of picagreen to dsDNA. When the solution is excited, picagreen emits strong green fluorescence. The increased fluorescence intensity of picagreen is dependent on the concentration of ADA. The detection limit of the ADA is determined to be 2 U L(-1), which is lower than ADA cutoff value (4 U L(-1)) in the clinical requirement and more sensitive than most of the reported methods. Compared to other previous ADA sensors, the assay is not only label-free but also a turn-on signal, and possesses properties of lower cost and simpler detection system. Furthermore, this label-free strategy is also applicable to the assay of other enzymes and screening of corresponding inhibitors.
Collapse
Affiliation(s)
- X Zeng
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710062, People's Republic of China.
| | | | | | | | | | | | | |
Collapse
|
7
|
Cheng F, He Y, Xing XJ, Tan DD, Lin Y, Pang DW, Tang HW. A gold nanoparticle-based label free colorimetric aptasensor for adenosine deaminase detection and inhibition assay. Analyst 2015; 140:1572-7. [PMID: 25597304 DOI: 10.1039/c4an02070g] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A novel strategy for the fabrication of a colorimetric aptasensor using label free gold nanoparticles (AuNPs) is proposed in this work, and the strategy has been employed for the assay of adenosine deaminase (ADA) activity. The aptasensor consists of adenosine (AD) aptamer, AD and AuNPs. The design of the biosensor takes advantage of the special optical properties of AuNPs and the interaction between AuNPs and single-strand DNA. In the absence of ADA, the AuNPs are aggregated and are blue in color under appropriate salt concentration because of the grid structure of an AD aptamer when binding to AD, while in the presence of the analyte, AuNPs remain dispersed with red color under the same concentration of salt owing to ADA converting AD into inosine which has no affinity with the AD aptamer, thus allowing quantitative investigation of ADA activity. The present strategy is simple, cost-effective, selective and sensitive for ADA with a detection limit of 1.526 U L(-1), which is about one order of magnitude lower than that previously reported. In addition, a very low concentration of the inhibitor erythro-9-(2-hydroxy-3-nonyl) adenine (EHNA) could generate a distinguishable response. Therefore, the AuNP-based colorimetric biosensor has great potential in the diagnosis of ADA-relevant diseases and drug screening.
Collapse
Affiliation(s)
- Fen Cheng
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, State Key Laboratory of Virology, and Wuhan Institute of Biotechnology, Wuhan University, Wuhan, 430072, P. R. China.
| | | | | | | | | | | | | |
Collapse
|
8
|
Wang C, Tang Y, Guo Y. Adenosine deaminase biosensor combining cationic conjugated polymer-based FRET with deoxyguanosine-based photoinduced electron transfer. ACS APPLIED MATERIALS & INTERFACES 2014; 6:21686-21691. [PMID: 25360869 DOI: 10.1021/am506832y] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
We demonstrated a sensitive and selective adenosine deaminase (ADA) detection by modulating the fluorescence resonance energy transfer (FRET) between cationic conjugated poly(9,9-bis(6'-N,N,N-trimethylammonium) hexyl)fluorine phenylene) (PFP) and the deoxyguanosine-tailored hairpin aptamer. The hairpin aptamer was labeled with a fluorophore FAM at one end and three deoxyguanosines (Gs) at the other end as a quencher. In the absence of ADA, aptamer forms hairpin-like conformation with adenosines making close affinity of Gs and FAM, which results in the weak FRET from PFP to FAM because of FAM fluorescence being quenched by Gs via photoinduced electron transfer (PET). After addition of ADA, adenosine was hydrolyzed by ADA, followed by the release of free aptamer. In this case, FAM being far away from Gs, the strong FRET thus was obtained due to the quenching process being blocked. Therefore, the new strategy based on the FRET ratio enhancement is reasonably used to detect the ADA sensitively, combining the fluorescence signal amplification of conjugated polymers with the initiative signal decreasing by Gs. The detection limit of the ADA assay is 0.3 U/L in both buffer solution and human serum, which is more sensitive than most of those previously documented methods. Importantly, the assay is rapid, homogeneous, and simple without a complicated treating process. The ADA inhibitor, erythro-9-(2-hydroxy-3-nonyl) adenine hydrochloride (EHNA), was also studied based on this assay, and the detection limit of EHNA is 10 pM. This strategy provides a new platform for the detection of other biomolecules and enzymes.
Collapse
Affiliation(s)
- Chun Wang
- Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University , Xi'an 710062, P. R. China
| | | | | |
Collapse
|