1
|
Tong Z, Shen C, Li Q, Yin H, Mao H. Combining sensors and actuators with electrowetting-on-dielectric (EWOD): advanced digital microfluidic systems for biomedical applications. Analyst 2023; 148:1399-1421. [PMID: 36752059 DOI: 10.1039/d2an01707e] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
The concept of digital microfluidics (DMF) enables highly flexible and precise droplet manipulation at a picoliter scale, making DMF a promising approach to realize integrated, miniaturized "lab-on-a-chip" (LOC) systems for research and clinical purposes. Owing to its simplicity and effectiveness, electrowetting-on-dielectric (EWOD) is one of the most commonly studied and applied effects to implement DMF. However, complex biomedical assays usually require more sophisticated sample handling and detection capabilities than basic EWOD manipulation. Alternatively, combined systems integrating EWOD actuators and other fluidic handling techniques are essential for bringing DMF into practical use. In this paper, we briefly review the main approaches for the integration/combination of EWOD with other microfluidic manipulation methods or additional external fields for specified biomedical applications. The form of integration ranges from independently operating sub-systems to fully coupled hybrid actuators. The corresponding biomedical applications of these works are also summarized to illustrate the significance of these innovative combination attempts.
Collapse
Affiliation(s)
- Zhaoduo Tong
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China. .,Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Chuanjie Shen
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China. .,Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Qiushi Li
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
| | - Hao Yin
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China. .,Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Hongju Mao
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
| |
Collapse
|
2
|
Bian X, Huang H, Chen L, Shen X. Droplet Tweezers Based on the Hydrophilic-Hydrophobic Interface Structure and Their Biological Application. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2022; 38:13522-13531. [PMID: 36288502 DOI: 10.1021/acs.langmuir.2c02074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Droplet controllable operation has wide applications in microfluidics, biomedicine, microreactors, and other fields. Droplets can spontaneously transfer from a high-energy state to a low-energy state, but how to reverse transfer the droplets is a difficult task. In this article, we use a special hydrophilic-hydrophobic interphase structure (HHIS) to achieve this reverse transfer. We specifically study the critical conditions under which droplet transfer can be achieved. The length of the hydrophilic surface in this structure and the hydrophilic/hydrophobic properties of the surface must be in the appropriate range. Based on this, an optimized structure used to transfer droplets was designed. Finally, we carried out research on biological applications and successfully achieved the transfer of droplets from zebrafish eggs and zebrafish larvae. This unique method is low-cost, biofriendly, and highly applicable to various surfaces, illustrating the great potential in chemical and biological analysis.
Collapse
Affiliation(s)
- Xiongheng Bian
- ChinaSchool of Information Science and Technology, Nantong University, Nantong 226019, China
| | - Haibo Huang
- Robotics & Microsystem Center & Collaborative Innovation Center of Suzhou Nano Science and Technology, Soochow University, Suzhou 215123,China
| | - Liguo Chen
- Robotics & Microsystem Center & Collaborative Innovation Center of Suzhou Nano Science and Technology, Soochow University, Suzhou 215123,China
| | - Xiaoyan Shen
- ChinaSchool of Information Science and Technology, Nantong University, Nantong 226019, China
| |
Collapse
|
3
|
Bian X, Chen L, Ma L, Shen X. Chopstick-Like Structure for the Free Transfer of Microdroplets in Robot Chemistry Laboratory. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2022; 38:13150-13157. [PMID: 36269326 DOI: 10.1021/acs.langmuir.2c01921] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
As we all know, chopsticks can hold food, so can we use this method to carry Newtonian fluids such as droplets? This paper studies the process of this transfer and uses this method to realize the manipulation of open microfluidics by robots. To realize this transfer operation, we first analyzed the force of droplets in this chopstick-like structure and found that the bidirectional movement of droplets in this structure can be achieved by changing the structural parameters. Afterward, the whole process of the transfer of droplets using the chopstick-like structure was analyzed, and the parameter requirements for realizing this transfer were determined. The research in this paper provides a theoretical basis for the controllable manipulation of droplets which can be widely used in unmanned laboratories.
Collapse
Affiliation(s)
- Xiongheng Bian
- School of Information Science and Technology, Nantong University, Nantong226019, China
| | - Liguo Chen
- Robotics & Microsystem Center & Collaborative Innovation Center of Suzhou Nano Science and Technology, Soochow University, Suzhou215123, China
| | - Lei Ma
- School of Information Science and Technology, Nantong University, Nantong226019, China
| | - Xiaoyan Shen
- School of Information Science and Technology, Nantong University, Nantong226019, China
| |
Collapse
|
4
|
Zhao Y, Gu L, Sun H, Sha X, Li WJ. Physical Cytometry: Detecting Mass-Related Properties of Single Cells. ACS Sens 2022; 7:21-36. [PMID: 34978200 DOI: 10.1021/acssensors.1c01787] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The physical properties of a single cell, such as mass, volume, and density, are important indications of the cell's metabolic characteristics and homeostasis. Precise measurement of a single cell's mass has long been a challenge due to its minute size. It is only in the past 10 years that a variety of instruments for measuring living cellular mass have emerged with the development of MEMS, microfluidics, and optics technologies. In this review, we discuss the current developments of physical cytometry for quantifying mass-related physical properties of single cells, highlighting the working principle, applications, and unique merits. The review mainly covers these measurement methods: single-cell mass cytometry, levitation image cytometry, suspended microchannel resonator, phase-shifting interferometry, and opto-electrokinetics cell manipulation. Comparisons are made between these methods in terms of throughput, content, invasiveness, compatibility, and precision. Some typical applications of these methods in pathological diagnosis, drug efficacy evaluation, disease treatment, and other related fields are also discussed in this work.
Collapse
Affiliation(s)
- Yuliang Zhao
- School of Control Engineering, Northeastern University, Qinhuangdao 066004, China
| | - Lijia Gu
- School of Control Engineering, Northeastern University, Qinhuangdao 066004, China
| | - Hui Sun
- Department of Mechanical Engineering, City University of Hong Kong, Kowloon, 999077 Hong Kong, China
| | - Xiaopeng Sha
- School of Control Engineering, Northeastern University, Qinhuangdao 066004, China
| | - Wen Jung Li
- Department of Mechanical Engineering, City University of Hong Kong, Kowloon, 999077 Hong Kong, China
| |
Collapse
|
5
|
Thio SK, Park SY. Optical Dielectrophoretic (DEP) Manipulation of Oil-Immersed Aqueous Droplets on a Plasmonic-Enhanced Photoconductive Surface. MICROMACHINES 2022; 13:112. [PMID: 35056277 PMCID: PMC8777958 DOI: 10.3390/mi13010112] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 01/04/2022] [Accepted: 01/09/2022] [Indexed: 02/04/2023]
Abstract
We present a plasmonic-enhanced dielectrophoretic (DEP) phenomenon to improve optical DEP performance of a floating electrode optoelectronic tweezers (FEOET) device, where aqueous droplets can be effectively manipulated on a light-patterned photoconductive surface immersed in an oil medium. To offer device simplicity and cost-effectiveness, recent studies have utilized a polymer-based photoconductive material such as titanium oxide phthalocyanine (TiOPc). However, the TiOPc has much poorer photoconductivity than that of semiconductors like amorphous silicon (a-Si), significantly limiting optical DEP applications. The study herein focuses on the FEOET device for which optical DEP performance can be greatly enhanced by utilizing plasmonic nanoparticles as light scattering elements to improve light absorption of the low-quality TiOPc. Numerical simulation studies of both plasmonic light scattering and electric field enhancement were conducted to verify wide-angle scattering light rays and an approximately twofold increase in electric field gradient with the presence of nanoparticles. Similarly, a spectrophotometric study conducted on the absorption spectrum of the TiOPc has shown light absorption improvement (nearly twofold) of the TiOPc layer. Additionally, droplet dynamics study experimentally demonstrated a light-actuated droplet speed of 1.90 mm/s, a more than 11-fold improvement due to plasmonic light scattering. This plasmonic-enhanced FEOET technology can considerably improve optical DEP capability even with poor-quality photoconductive materials, thus providing low-cost, easy-fabrication solutions for various droplet-based microfluidic applications.
Collapse
Affiliation(s)
- Si Kuan Thio
- Department of Mechanical Engineering, National University of Singapore, Singapore 117575, Singapore;
| | - Sung-Yong Park
- Department of Mechanical Engineering, San Diego State University, San Diego, CA 92182-1323, USA
| |
Collapse
|
6
|
Zhang S, Xu B, Elsayed M, Nan F, Liang W, Valley JK, Liu L, Huang Q, Wu MC, Wheeler AR. Optoelectronic tweezers: a versatile toolbox for nano-/micro-manipulation. Chem Soc Rev 2022; 51:9203-9242. [DOI: 10.1039/d2cs00359g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
This review covers the fundamentals, recent progress and state-of-the-art applications of optoelectronic tweezers technology, and demonstrates that optoelectronic tweezers technology is a versatile and powerful toolbox for nano-/micro-manipulation.
Collapse
Affiliation(s)
- Shuailong Zhang
- School of Mechatronical Engineering, Beijing Institute of Technology, Room 711, Building No 6, Science and Technology Park, 5 Zhongguancun South St, Haidian District, Beijing, 100081, China
- Beijing Advanced Innovation Center for Intelligent Robots and Systems, Beijing Institute of Technology, Beijing, 100081, China
- Key Laboratory of Biomimetic Robots and Systems (Beijing Institute of Technology), Ministry of Education, Beijing 100081, China
| | - Bingrui Xu
- School of Mechatronical Engineering, Beijing Institute of Technology, Room 711, Building No 6, Science and Technology Park, 5 Zhongguancun South St, Haidian District, Beijing, 100081, China
- Beijing Advanced Innovation Center for Intelligent Robots and Systems, Beijing Institute of Technology, Beijing, 100081, China
| | - Mohamed Elsayed
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON, M5S 3G9, Canada
- Donnelly Centre for Cellular and Biomolecular Research, University of Toronto, Toronto, ON, M5S 3E1, Canada
| | - Fan Nan
- Institute of Nanophotonics, Jinan University, Guangzhou 511443, China
| | - Wenfeng Liang
- School of Mechanical Engineering, Shenyang Jianzhu University, Shenyang, 110168, China
| | - Justin K. Valley
- Berkeley Lights, Inc, 5858 Horton Street #320, Emeryville, CA 94608, USA
| | - Lianqing Liu
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110016, China
| | - Qiang Huang
- School of Mechatronical Engineering, Beijing Institute of Technology, Room 711, Building No 6, Science and Technology Park, 5 Zhongguancun South St, Haidian District, Beijing, 100081, China
- Beijing Advanced Innovation Center for Intelligent Robots and Systems, Beijing Institute of Technology, Beijing, 100081, China
- Key Laboratory of Biomimetic Robots and Systems (Beijing Institute of Technology), Ministry of Education, Beijing 100081, China
| | - Ming C. Wu
- Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, California 94720, USA
| | - Aaron R. Wheeler
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON, M5S 3G9, Canada
- Donnelly Centre for Cellular and Biomolecular Research, University of Toronto, Toronto, ON, M5S 3E1, Canada
- Department of Chemistry, University of Toronto, Toronto, ON, M5S 3H6, Canada
| |
Collapse
|
7
|
Recent Advances on Thermal Management of Flexible Inorganic Electronics. MICROMACHINES 2020; 11:mi11040390. [PMID: 32283609 PMCID: PMC7231351 DOI: 10.3390/mi11040390] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 03/27/2020] [Accepted: 04/05/2020] [Indexed: 12/16/2022]
Abstract
Flexible inorganic electronic devices (FIEDs) consisting of functional inorganic components on a soft polymer substrate have enabled many novel applications such as epidermal electronics and wearable electronics, which cannot be realized through conventional rigid electronics. The low thermal dissipation capacity of the soft polymer substrate of FIEDs demands proper thermal management to reduce the undesired thermal influences. The biointegrated applications of FIEDs pose even more stringent requirements on thermal management due to the sensitive nature of biological tissues to temperature. In this review, we take microscale inorganic light-emitting diodes (μ-ILEDs) as an example of functional components to summarize the recent advances on thermal management of FIEDs including thermal analysis, thermo-mechanical analysis and thermal designs of FIEDs with and without biological tissues. These results are very helpful to understand the underlying heat transfer mechanism and provide design guidelines to optimize FIEDs in practical applications.
Collapse
|
8
|
Head-Mounted Display-Based Microscopic Imaging System with Customizable Field Size and Viewpoint. SENSORS 2020; 20:s20071967. [PMID: 32244620 PMCID: PMC7181164 DOI: 10.3390/s20071967] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Revised: 03/24/2020] [Accepted: 03/30/2020] [Indexed: 11/16/2022]
Abstract
In recent years, the use of microinjections has increased in life science and biotechnology fields; specific examples include artificial insemination and gene manipulation. Microinjections are mainly performed based on visual information; thus, the operator needs high-level skill because of the narrowness of the visual field. Additionally, microinjections are performed as the operator views a microscopic image on a display; the position of the display requires the operator to maintain an awkward posture throughout the procedure. In this study, we developed a microscopic image display apparatus for microinjections based on a view-expansive microscope. The prototype of the view-expansive microscope has problems related to the variations in brightness and focal blur that accompany changes in the optical path length and amount of reflected light. Therefore, we propose the use of a variable-focus device to expand the visual field and thus circumvent the above-mentioned problems. We evaluated the observable area of the system using this variable-focus device. We confirmed that the observable area is 261.4 and 13.9 times larger than that of a normal microscope and conventional view-expansive microscopic system, respectively. Finally, observations of mouse embryos were carried out by using the developed system. We confirmed that the microscopic images can be displayed on a head-mounted display in real time with the desired point and field sizes.
Collapse
|
9
|
Liang W, Liu L, Wang J, Yang X, Wang Y, Li WJ, Yang W. A Review on Optoelectrokinetics-Based Manipulation and Fabrication of Micro/Nanomaterials. MICROMACHINES 2020; 11:mi11010078. [PMID: 31936694 PMCID: PMC7019850 DOI: 10.3390/mi11010078] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Revised: 01/07/2020] [Accepted: 01/08/2020] [Indexed: 12/20/2022]
Abstract
Optoelectrokinetics (OEK), a fusion of optics, electrokinetics, and microfluidics, has been demonstrated to offer a series of extraordinary advantages in the manipulation and fabrication of micro/nanomaterials, such as requiring no mask, programmability, flexibility, and rapidness. In this paper, we summarize a variety of differently structured OEK chips, followed by a discussion on how they are fabricated and the ways in which they work. We also review how three differently sized polystyrene beads can be separated simultaneously, how a variety of nanoparticles can be assembled, and how micro/nanomaterials can be fabricated into functional devices. Another focus of our paper is on mask-free fabrication and assembly of hydrogel-based micro/nanostructures and its possible applications in biological fields. We provide a summary of the current challenges facing the OEK technique and its future prospects at the end of this paper.
Collapse
Affiliation(s)
- Wenfeng Liang
- School of Mechanical Engineering, Shenyang Jianzhu University, Shenyang 110168, China; (W.L.); (J.W.); (X.Y.)
| | - Lianqing Liu
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China;
- CAS-CityU Joint Laboratory on Robotics, City University of Hong Kong, Kowloon Tong, Hong Kong 999077, China
- Correspondence: (L.L.); (W.J.L.); Tel.: +86-24-2397-0181 (L.L.); +852-3442-9266 (W.J.L.)
| | - Junhai Wang
- School of Mechanical Engineering, Shenyang Jianzhu University, Shenyang 110168, China; (W.L.); (J.W.); (X.Y.)
| | - Xieliu Yang
- School of Mechanical Engineering, Shenyang Jianzhu University, Shenyang 110168, China; (W.L.); (J.W.); (X.Y.)
| | - Yuechao Wang
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China;
- CAS-CityU Joint Laboratory on Robotics, City University of Hong Kong, Kowloon Tong, Hong Kong 999077, China
| | - Wen Jung Li
- CAS-CityU Joint Laboratory on Robotics, City University of Hong Kong, Kowloon Tong, Hong Kong 999077, China
- Department of Mechanical Engineering, City University of Hong Kong, Kowloon Tong, Hong Kong 999077, China
- Correspondence: (L.L.); (W.J.L.); Tel.: +86-24-2397-0181 (L.L.); +852-3442-9266 (W.J.L.)
| | - Wenguang Yang
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai 264005, China;
| |
Collapse
|
10
|
Liang W, Liu L, Zhang H, Wang Y, Li WJ. Optoelectrokinetics-based microfluidic platform for bioapplications: A review of recent advances. BIOMICROFLUIDICS 2019; 13:051502. [PMID: 31558919 PMCID: PMC6748859 DOI: 10.1063/1.5116737] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2019] [Accepted: 09/05/2019] [Indexed: 05/14/2023]
Abstract
The introduction of optoelectrokinetics (OEK) into lab-on-a-chip systems has facilitated a new cutting-edge technique-the OEK-based micro/nanoscale manipulation, separation, and assembly processes-for the microfluidics community. This technique offers a variety of extraordinary advantages such as programmability, flexibility, high biocompatibility, low-cost mass production, ultralow optical power requirement, reconfigurability, rapidness, and ease of integration with other microfluidic units. This paper reviews the physical mechanisms that govern the manipulation of micro/nano-objects in microfluidic environments as well as applications related to OEK-based micro/nanoscale manipulation-applications that span from single-cell manipulation to single-molecular behavior determination. This paper wraps up with a discussion of the current challenges and future prospects for the OEK-based microfluidics technique. The conclusion is that this technique will allow more opportunities for biomedical and bioengineering researchers to improve lab-on-a-chip technologies and will have far-reaching implications for biorelated researches and applications in the future.
Collapse
Affiliation(s)
- Wenfeng Liang
- School of Mechanical Engineering, Shenyang Jianzhu University, Shenyang 110168, China
| | - Lianqing Liu
- Authors to whom correspondence should be addressed: and
| | - Hemin Zhang
- Department of Neurology, The People’s Hospital of Liaoning Province, Shenyang 110016, China
| | | | - Wen Jung Li
- Authors to whom correspondence should be addressed: and
| |
Collapse
|
11
|
Li J, Hill EH, Lin L, Zheng Y. Optical Nanoprinting of Colloidal Particles and Functional Structures. ACS NANO 2019; 13:3783-3795. [PMID: 30875190 PMCID: PMC6482071 DOI: 10.1021/acsnano.9b01034] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Recent advances in chemical sciences have enabled the tailorable synthesis of colloidal particles with variable composition, size, shape, and properties. Building superstructures with colloidal particles as building blocks is appealing for the fabrication of functional metamaterials and nanodevices. Optical nanoprinting provides a versatile platform to print various particles into arbitrary configurations with nanometric precision. In this review, we summarize recent progress in optical nanoprinting of colloidal particles and its related applications. Diverse techniques based on different physical mechanisms, including optical forces, light-controlled electric fields, optothermal effects, laser-directed thermocapillary flows, and photochemical reactions, are discussed in detail. With its flexible and versatile capabilities, optical nanoprinting will find promising applications in numerous fields such as nanophotonics, energy, microelectronics, and nanomedicine.
Collapse
Affiliation(s)
- Jingang Li
- Department of Mechanical Engineering, Materials Science & Engineering Program and Texas Materials Institute, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Eric H. Hill
- Institute of Advanced Ceramics, Hamburg University of Technology, 21073 Hamburg, Germany
| | - Linhan Lin
- Department of Mechanical Engineering, Materials Science & Engineering Program and Texas Materials Institute, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Yuebing Zheng
- Department of Mechanical Engineering, Materials Science & Engineering Program and Texas Materials Institute, The University of Texas at Austin, Austin, Texas 78712, United States
| |
Collapse
|
12
|
Atajanov A, Zhbanov A, Yang S. Sorting and manipulation of biological cells and the prospects for using optical forces. MICRO AND NANO SYSTEMS LETTERS 2018. [DOI: 10.1186/s40486-018-0064-3] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
13
|
Wu Y, Ozcan A. Lensless digital holographic microscopy and its applications in biomedicine and environmental monitoring. Methods 2017; 136:4-16. [PMID: 28864356 DOI: 10.1016/j.ymeth.2017.08.013] [Citation(s) in RCA: 70] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2017] [Revised: 08/23/2017] [Accepted: 08/24/2017] [Indexed: 01/06/2023] Open
Abstract
Optical compound microscope has been a major tool in biomedical imaging for centuries. Its performance relies on relatively complicated, bulky and expensive lenses and alignment mechanics. In contrast, the lensless microscope digitally reconstructs microscopic images of specimens without using any lenses, as a result of which it can be made much smaller, lighter and lower-cost. Furthermore, the limited space-bandwidth product of objective lenses in a conventional microscope can be significantly surpassed by a lensless microscope. Such lensless imaging designs have enabled high-resolution and high-throughput imaging of specimens using compact, portable and cost-effective devices to potentially address various point-of-care, global-health and telemedicine related challenges. In this review, we discuss the operation principles and the methods behind lensless digital holographic on-chip microscopy. We also go over various applications that are enabled by cost-effective and compact implementations of lensless microscopy, including some recent work on air quality monitoring, which utilized machine learning for high-throughput and accurate quantification of particulate matter in air. Finally, we conclude with a brief future outlook of this computational imaging technology.
Collapse
Affiliation(s)
- Yichen Wu
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA; Bioengineering Department, University of California, Los Angeles, CA 90095, USA; California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095, USA
| | - Aydogan Ozcan
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA; Bioengineering Department, University of California, Los Angeles, CA 90095, USA; California NanoSystems Institute (CNSI), University of California, Los Angeles, CA 90095, USA; David Geffen School of Medicine, University of California, Los Angeles, CA 90095, USA.
| |
Collapse
|
14
|
Zhang Y, Wittstock G. A Platform for Electric Field Aided and Wire-Guided Droplet Manipulation. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2017; 13:1601691. [PMID: 27860309 DOI: 10.1002/smll.201601691] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2016] [Revised: 09/30/2016] [Indexed: 06/06/2023]
Abstract
Small droplets can be manipulated based on controlling the adhesion work to a hydrophobic wire. The wire can be used to pick up, transport, and lay down droplets with volumes between picoliters to microliters avoiding the sliding of droplets over chip surfaces. Handling of droplets on surfaces with large steps such as engraved wells or channels is possible.
Collapse
Affiliation(s)
- Yanzhen Zhang
- Carl von Ossietzky University of Oldenburg, Faculty of Mathematics and Science, Center of Interface Sciences, Institute of Chemistry, D-26111, Oldenburg, Germany
| | - Gunther Wittstock
- Carl von Ossietzky University of Oldenburg, Faculty of Mathematics and Science, Center of Interface Sciences, Institute of Chemistry, D-26111, Oldenburg, Germany
| |
Collapse
|
15
|
|
16
|
Kung YC, Huang KW, Chong W, Chiou PY. Tunnel Dielectrophoresis for Tunable, Single-Stream Cell Focusing in Physiological Buffers in High-Speed Microfluidic Flows. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2016; 12:4343-8. [PMID: 27348575 DOI: 10.1002/smll.201600996] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2016] [Revised: 05/14/2016] [Indexed: 05/08/2023]
Abstract
A novel tunnel dielectrophoresis (TDEP) mechanism is demonstrated for continuously tunable, sheathless, 3D, and single-stream microparticle and cell focusing in high-speed flows in regular physiological buffers. Particles and cells showing negative DEP responses can be focused at the electric field minimum location regardless of their types and sizes.
Collapse
Affiliation(s)
- Yu-Chun Kung
- Department of Mechanical and Aerospace Engineering, University of California at Los Angeles (UCLA), 14-124 Eng. IV, 420 Westwood Plaza, Los Angeles, CA, 90095-1597, USA
| | - Kuo-Wei Huang
- Department of Mechanical and Aerospace Engineering, University of California at Los Angeles (UCLA), 14-124 Eng. IV, 420 Westwood Plaza, Los Angeles, CA, 90095-1597, USA
| | - William Chong
- Department of Mechanical and Aerospace Engineering, University of California at Los Angeles (UCLA), 14-124 Eng. IV, 420 Westwood Plaza, Los Angeles, CA, 90095-1597, USA
| | - Pei-Yu Chiou
- Department of Mechanical and Aerospace Engineering, University of California at Los Angeles (UCLA), 14-124 Eng. IV, 420 Westwood Plaza, Los Angeles, CA, 90095-1597, USA
| |
Collapse
|
17
|
McLeod E, Ozcan A. Unconventional methods of imaging: computational microscopy and compact implementations. REPORTS ON PROGRESS IN PHYSICS. PHYSICAL SOCIETY (GREAT BRITAIN) 2016; 79:076001. [PMID: 27214407 DOI: 10.1088/0034-4885/79/7/076001] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
In the past two decades or so, there has been a renaissance of optical microscopy research and development. Much work has been done in an effort to improve the resolution and sensitivity of microscopes, while at the same time to introduce new imaging modalities, and make existing imaging systems more efficient and more accessible. In this review, we look at two particular aspects of this renaissance: computational imaging techniques and compact imaging platforms. In many cases, these aspects go hand-in-hand because the use of computational techniques can simplify the demands placed on optical hardware in obtaining a desired imaging performance. In the first main section, we cover lens-based computational imaging, in particular, light-field microscopy, structured illumination, synthetic aperture, Fourier ptychography, and compressive imaging. In the second main section, we review lensfree holographic on-chip imaging, including how images are reconstructed, phase recovery techniques, and integration with smart substrates for more advanced imaging tasks. In the third main section we describe how these and other microscopy modalities have been implemented in compact and field-portable devices, often based around smartphones. Finally, we conclude with some comments about opportunities and demand for better results, and where we believe the field is heading.
Collapse
Affiliation(s)
- Euan McLeod
- College of Optical Sciences, University of Arizona, Tucson, AZ 85721, USA
| | | |
Collapse
|
18
|
Liang W, Wang Y, Zhang H, Liu L. Characterization of the self-rotational motion of stored red blood cells by using optically-induced electrokinetics. OPTICS LETTERS 2016; 41:2763-6. [PMID: 27304283 DOI: 10.1364/ol.41.002763] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
We report a label-free approach toward the object of characterizing the self-rotational motions of red blood cells (RBCs) during storage under the optically-induced electrokinetics-based microfluidics mechanism. A theoretical analysis of the transmembrane potential across RBCs was performed getting a threshold voltage for keeping cellular biological integrity. Then, by investigation of the self-rotational behaviors of the individual RBCs in larger population, the RBCs that were stored more than three weeks statistically showed the distinctive self-rotational speed. Results verified that the self-rotational biomarkers of the RBCs could be used to label-free reckon the qualities of the stored RBCs in this kind of microfluidics chip. This finding may be further developed as a new criterion to real-time and label-free monitoring of the banked blood qualities, thereby diminishing the blood transfusion venture.
Collapse
|
19
|
Self-Locking Optoelectronic Tweezers for Single-Cell and Microparticle Manipulation across a Large Area in High Conductivity Media. Sci Rep 2016; 6:22630. [PMID: 26940301 PMCID: PMC4778053 DOI: 10.1038/srep22630] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Accepted: 02/18/2016] [Indexed: 01/23/2023] Open
Abstract
Optoelectronic tweezers (OET) has advanced within the past decade to become a promising tool for cell and microparticle manipulation. Its incompatibility with high conductivity media and limited throughput remain two major technical challenges. Here a novel manipulation concept and corresponding platform called Self-Locking Optoelectronic Tweezers (SLOT) are proposed and demonstrated to tackle these challenges concurrently. The SLOT platform comprises a periodic array of optically tunable phototransistor traps above which randomly dispersed single cells and microparticles are self-aligned to and retained without light illumination. Light beam illumination on a phototransistor turns off the trap and releases the trapped cell, which is then transported downstream via a background flow. The cell trapping and releasing functions in SLOT are decoupled, which is a unique feature that enables SLOT’s stepper-mode function to overcome the small field-of-view issue that all prior OET technologies encountered in manipulation with single-cell resolution across a large area. Massively parallel trapping of more than 100,000 microparticles has been demonstrated in high conductivity media. Even larger scale trapping and manipulation can be achieved by linearly scaling up the number of phototransistors and device area. Cells after manipulation on the SLOT platform maintain high cell viability and normal multi-day divisibility.
Collapse
|
20
|
Abstract
High-resolution optical microscopy has traditionally relied on high-magnification and high-numerical aperture objective lenses. In contrast, lensless microscopy can provide high-resolution images without the use of any focusing lenses, offering the advantages of a large field of view, high resolution, cost-effectiveness, portability, and depth-resolved three-dimensional (3D) imaging. Here we review various approaches to lensless imaging, as well as its applications in biosensing, diagnostics, and cytometry. These approaches include shadow imaging, fluorescence, holography, superresolution 3D imaging, iterative phase recovery, and color imaging. These approaches share a reliance on computational techniques, which are typically necessary to reconstruct meaningful images from the raw data captured by digital image sensors. When these approaches are combined with physical innovations in sample preparation and fabrication, lensless imaging can be used to image and sense cells, viruses, nanoparticles, and biomolecules. We conclude by discussing several ways in which lensless imaging and sensing might develop in the near future.
Collapse
Affiliation(s)
- Aydogan Ozcan
- Department of Electrical Engineering.,Department of Bioengineering, and.,California NanoSystems Institute, University of California, Los Angeles, California 90095;
| | - Euan McLeod
- College of Optical Sciences, University of Arizona, Tucson, Arizona 85721;
| |
Collapse
|
21
|
Lin L, Peng X, Mao Z, Li W, Yogeesh MN, Rajeeva BB, Perillo EP, Dunn AK, Akinwande D, Zheng Y. Bubble-Pen Lithography. NANO LETTERS 2016; 16:701-8. [PMID: 26678845 PMCID: PMC5490994 DOI: 10.1021/acs.nanolett.5b04524] [Citation(s) in RCA: 97] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Current lithography techniques, which employ photon, electron, or ion beams to induce chemical or physical reactions for micro/nano-fabrication, have remained challenging in patterning chemically synthesized colloidal particles, which are emerging as building blocks for functional devices. Herein, we develop a new technique - bubble-pen lithography (BPL) - to pattern colloidal particles on substrates using optically controlled microbubbles. Briefly, a single laser beam generates a microbubble at the interface of colloidal suspension and a plasmonic substrate via plasmon-enhanced photothermal effects. The microbubble captures and immobilizes the colloidal particles on the substrate through coordinated actions of Marangoni convection, surface tension, gas pressure, and substrate adhesion. Through directing the laser beam to move the microbubble, we create arbitrary single-particle patterns and particle assemblies with different resolutions and architectures. Furthermore, we have applied BPL to pattern CdSe/ZnS quantum dots on plasmonic substrates and polystyrene (PS) microparticles on two-dimensional (2D) atomic-layer materials. With the low-power operation, arbitrary patterning and applicability to general colloidal particles, BPL will find a wide range of applications in microelectronics, nanophotonics, and nanomedicine.
Collapse
Affiliation(s)
- Linhan Lin
- Department of Mechanical Engineering, The University of Texas at Austin , Austin, Texas 78712, United States
- Materials Science & Engineering Program and Texas Materials Institute, The University of Texas at Austin , Austin, Texas 78712, United States
| | - Xiaolei Peng
- Materials Science & Engineering Program and Texas Materials Institute, The University of Texas at Austin , Austin, Texas 78712, United States
| | - Zhangming Mao
- Department of Engineering Science and Mechanics, The Pennsylvania State University , University Park, Pennsylvania 16802, United States
| | - Wei Li
- Materials Science & Engineering Program and Texas Materials Institute, The University of Texas at Austin , Austin, Texas 78712, United States
- Microelectronics Research Centre, The University of Texas at Austin , Austin, Texas 78758, United States
| | - Maruthi N Yogeesh
- Microelectronics Research Centre, The University of Texas at Austin , Austin, Texas 78758, United States
| | - Bharath Bangalore Rajeeva
- Materials Science & Engineering Program and Texas Materials Institute, The University of Texas at Austin , Austin, Texas 78712, United States
| | - Evan P Perillo
- Department of Biomedical Engineering, The University of Texas at Austin , Austin, Texas 78712, United States
| | - Andrew K Dunn
- Department of Biomedical Engineering, The University of Texas at Austin , Austin, Texas 78712, United States
| | - Deji Akinwande
- Materials Science & Engineering Program and Texas Materials Institute, The University of Texas at Austin , Austin, Texas 78712, United States
- Microelectronics Research Centre, The University of Texas at Austin , Austin, Texas 78758, United States
| | - Yuebing Zheng
- Department of Mechanical Engineering, The University of Texas at Austin , Austin, Texas 78712, United States
- Materials Science & Engineering Program and Texas Materials Institute, The University of Texas at Austin , Austin, Texas 78712, United States
| |
Collapse
|
22
|
A microfluidic digital single-cell assay for the evaluation of anticancer drugs. Anal Bioanal Chem 2014; 407:1139-48. [PMID: 25433683 DOI: 10.1007/s00216-014-8325-3] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2014] [Revised: 11/04/2014] [Accepted: 11/05/2014] [Indexed: 10/24/2022]
Abstract
Digital single-cell assays hold high potentials for the analysis of cell apoptosis and the evaluation of chemotherapeutic reagents for cancer therapy. In this paper, a microfluidic hydrodynamic trapping system was developed for digital single-cell assays with the capability of monitoring cellular dynamics over time. The microfluidic chip was designed with arrays of bypass structures for trapping individual cells without the need for surface modification, external electric force, or robotic equipment. After optimization of the bypass structure by both numerical simulations and experiments, a single-cell trapping efficiency of ∼90 % was achieved. We demonstrated the method as a digital single-cell assay for the evaluation of five clinically established chemotherapeutic reagents. As a result, the half maximal inhibitory concentration (IC50) values of these compounds could be conveniently determined. We further modeled the gradual decrease of active drugs over time which was often observed in vivo after an injection to investigate cell apoptosis against chemotherapeutic reagents. The developed method provided a valuable means for cell apoptotic analysis and evaluation of anticancer drugs.
Collapse
|
23
|
Zhao Y, Lai HSS, Zhang G, Lee GB, Li WJ. Rapid determination of cell mass and density using digitally controlled electric field in a microfluidic chip. LAB ON A CHIP 2014; 14:4426-34. [PMID: 25254511 DOI: 10.1039/c4lc00795f] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
The density of a single cell is a fundamental property of cells. Cells in the same cycle phase have similar volume, but the differences in their mass and density could elucidate each cell's physiological state. Here we report a novel technique to rapidly measure the density and mass of a single cell using an optically induced electrokinetics (OEK) microfluidic platform. Presently, single cellular mass and density measurement devices require a complicated fabrication process and their output is not scalable, i.e., it is extremely difficult to measure the mass and density of a large quantity of cells rapidly. The technique reported here operates on a principle combining sedimentation theory, computer vision, and microparticle manipulation techniques in an OEK microfluidic platform. We will show in this paper that this technique enables the measurement of single-cell volume, density, and mass rapidly and accurately in a repeatable manner. The technique is also scalable - it allows simultaneous measurement of volume, density, and mass of multiple cells. Essentially, a simple time-controlled projected light pattern is used to illuminate the selected area on the OEK microfluidic chip that contains cells to lift the cells to a particular height above the chip's surface. Then, the cells are allowed to "free fall" to the chip's surface, with competing buoyancy, gravitational, and fluidic drag forces acting on the cells. By using a computer vision algorithm to accurately track the motion of the cells and then relate the cells' motion trajectory to sedimentation theory, the volume, mass, and density of each cell can be rapidly determined. A theoretical model of micro-sized spheres settling towards an infinite plane in a microfluidic environment is first derived and validated experimentally using standard micropolystyrene beads to demonstrate the viability and accuracy of this new technique. Next, we show that the yeast cell volume, mass, and density could be rapidly determined using this technology, with results comparable to those using the existing method suspended microchannel resonator.
Collapse
Affiliation(s)
- Yuliang Zhao
- Dept. of Mechanical and Biomedical Engineering, City University of Hong Kong, Hong Kong.
| | | | | | | | | |
Collapse
|
24
|
Mishra A, Kwon JS, Thakur R, Wereley S. Optoelectrical microfluidics as a promising tool in biology. Trends Biotechnol 2014; 32:414-21. [DOI: 10.1016/j.tibtech.2014.06.002] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2013] [Revised: 05/29/2014] [Accepted: 06/02/2014] [Indexed: 01/29/2023]
|
25
|
Bianco V, Merola F, Miccio L, Memmolo P, Gennari O, Paturzo M, Netti PA, Ferraro P. Imaging adherent cells in the microfluidic channel hidden by flowing RBCs as occluding objects by a holographic method. LAB ON A CHIP 2014; 14:2499-504. [PMID: 24852283 DOI: 10.1039/c4lc00290c] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Imaging through turbid media is a challenging topic. A liquid is considered turbid when dispersed particles provoke strong light scattering, thus destroying the image formation by any standard optical system. Generally, colloidal solutions belong to the class of turbid media since dispersed particles have dimensions ranging between 0.2 μm and 2 μm. However, in microfluidics, another relevant issue has to be considered in the case of flowing liquid made of a multitude of occluding objects, e.g. red blood cells (RBCs) flowing in veins. In such a case instead of severe scattering processes unpredictable phase delays occur resulting in a wavefront distortion, thus disturbing or even hindering the image formation of objects behind such obstructing layer. In fact RBCs can be considered to be thin transparent phase objects. Here we show that sharp amplitude imaging and phase-contrast mapping of cells hidden behind biological occluding objects, namely RBCs, is possible in harsh noise conditions and with a large field-of view by Multi-Look Digital Holography microscopy (ML-DH). Noteworthy, we demonstrate that ML-DH benefits from the presence of the RBCs, providing enhancement in terms of numerical resolution and noise suppression thus obtaining images whose quality is higher than the quality achievable in the case of a liquid without occlusive objects.
Collapse
Affiliation(s)
- Vittorio Bianco
- CNR-National Institute of Optics (INO), Via Campi Flegrei, 34, I-80078, Pozzuoli (NA), Italy.
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Miccio L, Memmolo P, Merola F, Fusco S, Embrione V, Paciello A, Ventre M, Netti PA, Ferraro P. Particle tracking by full-field complex wavefront subtraction in digital holography microscopy. LAB ON A CHIP 2014; 14:1129-34. [PMID: 24463986 DOI: 10.1039/c3lc51104a] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The 3D tracking of micro-objects, based on digital holography, is proposed through the analysis of the complex wavefront of the light scattered by the micro-samples. Exploiting the advantages of the off-axis full-field holographic interferometry, the tracking of multiple objects is achieved by a direct wavefront analysis at the focal plane overcoming the limitation of the conventional back focal plane interferometry in which only one object at a time can be tracked. Furthermore, the method proposed and demonstrated here is a step forward with respect to other holographic tracking tools. The approach is tested in two experiments, the first investigates the Brownian motion of particles trapped by holographic optical tweezers, while the second relates to the cell motility in a 3D collagen matrix, thus showing its usefulness for lab-on-chip systems in typical bioassay testing.
Collapse
Affiliation(s)
- L Miccio
- CNR - National Institute of Optics, 80078 Pozzuoli, Italy.
| | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Huang KW, Wu YC, Lee JA, Chiou PY. Microfluidic integrated optoelectronic tweezers for single-cell preparation and analysis. LAB ON A CHIP 2013; 13:3721-7. [PMID: 23884358 DOI: 10.1039/c3lc50607j] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
We report a novel microfluidic integrated optoelectronic tweezers (OET) platform for single-cell sample preparation and analysis. Integration of OET and microfluidics is achieved by embedding single-wall carbon nanotube (SWNT) electrodes into multilayer PDMS structures. This integrated platform allows users to selectively pick up individual cells from a population with light beams based on their optical signatures such as size, shape, and fluorescence, and transport them into isolated chambers using light induced dielectrophoretic forces. Isolated cells can be encapsulated into nanoliter liquid plugs and transported out of the platform for downstream molecule analysis using standard commercial instruments.
Collapse
Affiliation(s)
- Kuo-Wei Huang
- Department of Mechanical and Aerospace Engineering, University of California, Los Angeles, CA 90095, USA
| | | | | | | |
Collapse
|