1
|
Kim K, Lee WG. Portable, Automated and Deep-Learning-Enabled Microscopy for Smartphone-Tethered Optical Platform Towards Remote Homecare Diagnostics: A Review. SMALL METHODS 2023; 7:e2200979. [PMID: 36420919 DOI: 10.1002/smtd.202200979] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 10/18/2022] [Indexed: 06/16/2023]
Abstract
Globally new pandemic diseases induce urgent demands for portable diagnostic systems to prevent and control infectious diseases. Smartphone-based portable diagnostic devices are significantly efficient tools to user-friendly connect personalized health conditions and collect valuable optical information for rapid diagnosis and biomedical research through at-home screening. Deep learning algorithms for portable microscopes also help to enhance diagnostic accuracy by reducing the imaging resolution gap between benchtop and portable microscopes. This review highlighted recent progress and continued efforts in a smartphone-tethered optical platform through portable, automated, and deep-learning-enabled microscopy for personalized diagnostics and remote monitoring. In detail, the optical platforms through smartphone-based microscopes and lens-free holographic microscopy are introduced, and deep learning-based portable microscopic imaging is explained to improve the image resolution and accuracy of diagnostics. The challenges and prospects of portable optical systems with microfluidic channels and a compact microscope to screen COVID-19 in the current pandemic are also discussed. It has been believed that this review offers a novel guide for rapid diagnosis, biomedical imaging, and digital healthcare with low cost and portability.
Collapse
Affiliation(s)
- Kisoo Kim
- Intelligent Optical Module Research Center, Korea Photonics Technology Institute (KOPTI), Buk-gu, Gwangju, 61007, Republic of Korea
| | - Won Gu Lee
- Department of Mechanical Engineering, Kyung Hee University, Yongin, 17104, Republic of Korea
| |
Collapse
|
2
|
Tharakan S, Faqah O, Asghar W, Ilyas A. Microfluidic Devices for HIV Diagnosis and Monitoring at Point-of-Care (POC) Settings. BIOSENSORS 2022; 12:949. [PMID: 36354458 PMCID: PMC9687700 DOI: 10.3390/bios12110949] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/19/2022] [Accepted: 10/27/2022] [Indexed: 06/16/2023]
Abstract
Human immunodeficiency virus (HIV) is a global epidemic; however, many individuals are able to obtain treatment and manage their condition. Progression to acquired immunodeficiency syndrome (AIDS) occurs during late-stage HIV infection, which compromises the immune system, making it susceptible to infections. While there is no cure, antiretroviral therapy can be used provided that detection occurs, preferably during the early phase. However, the detection of HIV is expensive and resource-intensive when tested with conventional methods, such as flow cytometry, polymerase chain reaction (PCR), or enzyme-linked immunosorbent assays (ELISA). Improving disease detection in resource-constrained areas requires equipment that is affordable, portable, and can deliver rapid results. Microfluidic devices have transformed many benchtop techniques to on-chip detection for portable and rapid point-of-care (POC) testing. These devices are cost-effective, sensitive, and rapid and can be used in areas lacking resources. Moreover, their functionality can rival their benchtop counterparts, making them efficient for disease detection. In this review, we discuss the limitations of currently used conventional HIV diagnostic assays and provide an overview of potential microfluidic technologies that can improve HIV testing in POC settings.
Collapse
Affiliation(s)
- Shebin Tharakan
- Bio-Nanotechnology and Biomaterials (BNB) Lab, New York Institute of Technology, Old Westbury, NY 11568, USA
- Department of Biological & Chemical Sciences, New York Institute of Technology, Old Westbury, NY 11568, USA
| | - Omair Faqah
- Department of Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL 33431, USA
| | - Waseem Asghar
- Department of Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL 33431, USA
| | - Azhar Ilyas
- Bio-Nanotechnology and Biomaterials (BNB) Lab, New York Institute of Technology, Old Westbury, NY 11568, USA
- Department of Electrical and Computer Engineering, New York Institute of Technology, Old Westbury, NY 11568, USA
| |
Collapse
|
3
|
Jang Y, Han S, Song C, Jung J, Oh J. Miniaturized optimal incident light angle-fitted dark field system for contrast-enhanced real-time monitoring of 2D/3D-projected cell motions. JOURNAL OF BIOPHOTONICS 2022; 15:e202200091. [PMID: 35770625 DOI: 10.1002/jbio.202200091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 05/24/2022] [Accepted: 06/15/2022] [Indexed: 06/15/2023]
Abstract
In the field of biology, dark field microscopy provides superior insight into cells and subcellular structures. However, most dark field microscopes are equipped with a dark field filter and a light source on a 2D-based specimen, so only a flat sample can be observed in a limited space. We propose a compact cell monitoring system with built-in dark field filter with an optimized incident angle of the light source to provide real-time cell imaging and spatial cell monitoring for long-term free from phototoxicity. 2D projection imaging was implemented using a modular condenser lens to acquire high-contrast images. This enabled the long-term monitoring of cells, and the real-time monitoring of cell division and death. This system was able to image, by 2D projection, cells on the surface thinly coated with multiwalled carbon nanotubes, as well as living cells that migrated along the surface of glass beads and hydrogel droplets with a diameter of about 160 μm. The optimal incident light angle-fitted dark field system combines high-contrast imaging sensitivity and high spatial resolution to even image cells on 3D surfaces.
Collapse
Affiliation(s)
- Yeongseok Jang
- Department of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeonju, South Korea
| | - Seungbeom Han
- Department of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeonju, South Korea
| | - Chulgyu Song
- Division of Electronic Engineering, College of Engineering, Jeonbuk National University, Jeonju, South Korea
| | - Jinmu Jung
- Department of Nano-Bio Mechanical System Engineering, College of Engineering, Jeonbuk National University, Jeonju, South Korea
| | - Jonghyun Oh
- Department of Nano-Bio Mechanical System Engineering, College of Engineering, Jeonbuk National University, Jeonju, South Korea
| |
Collapse
|
4
|
Tyagi A, Khaware N, Tripathi BS, Jeet T, Balasubramanian P, Elangovan R. i-scope: A Compact automated fluorescence microscope for cell counting applications in low resource settings. Methods Appl Fluoresc 2022; 10. [PMID: 36063812 DOI: 10.1088/2050-6120/ac8f84] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Accepted: 09/05/2022] [Indexed: 11/11/2022]
Abstract
Fluorescence microscopy has widespread applications across biological sciences. It has been routinely used for cell counting, which provides a preliminary diagnostic test for many infectious diseases. Conventional fluorescence microscopes are bulky, expensive, time-intensive and laborious. They often require trained operators to acquire and analyze data. We report a compact automated digital fluorescence microscopy system, i-scope, for cell counting applications. The i-scope employs a total internal reflection fluorescence (TIRF) mode of sample illumination, along with a brightfield mode. It has a magnification of 30X, an optical resolution of ~0.2 µm/pixel and offers sample scanning over 20 mm x 20 mm. A custom-written program enables automated image acquisition and analysis, thereby enhancing ease of operation. It has a compact form-factor and has been developed into a standalone system with a processing unit, screen, and other accessories to offer a portable and economic point-of-care diagnostic solution in low-resource settings. We analysed the performance of the i-scope for milk somatic cell enumeration and benchmarked it against that of a conventional fluorescence microscope.
Collapse
Affiliation(s)
- Arti Tyagi
- Department of Biochemical Engineering and Biotechnology, Indian Institute of Technology Delhi, Room 335, Block 1, IIT Delhi, Hauz Khas, New Delhi, 110016, INDIA
| | - Neha Khaware
- School of Interdisciplinary Research, Indian Institute of Technology Delhi, IIT Delhi, Hauz Khas, New Delhi, 110016, INDIA
| | - Bramha Swaroop Tripathi
- Department of Biochemical Engineering and Biotechnology, Indian Institute of Technology Delhi, IIT Delhi, Hauz Khas, New Delhi, 110016, INDIA
| | - Tushar Jeet
- Department of Biochemical Engineering and Biotechnology, Indian Institute of Technology Delhi, IIT Delhi, Hauz Khas, New Delhi, 110016, INDIA
| | - Prabhu Balasubramanian
- Department of Biochemical Engineering and Biotechnology, Indian Institute of Technology Delhi, IIT Delhi, Hauz Khas, New Delhi, 110016, INDIA
| | - Ravikrishnan Elangovan
- Department of Biochemical Engineering and Biotechnology, Indian Institute of Technology Delhi, IIT Delhi, Hauz Khas, New Delhi, 110016, INDIA
| |
Collapse
|
5
|
Multi-Mode Compact Microscopy for High-Contrast and High-Resolution Imaging. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12157399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
We report a multi-mode compact microscope (MCM) for high-contrast and high-resolution imaging. The MCM consists of two LED illuminations, a magnification lens, a lift stage, and a housing with image processing and LED control boards. The MCM allows multi-modal imaging, including reflection, transmission, and higher magnification modes. The dual illuminations also provide high-contrast imaging of various targets such as biological samples and microcircuits. The high dynamic range (HDR) imaging reconstruction of MCM increases the dynamic range of the acquired images by 1.36 times. The microlens array (MLA)-assisted MCM also improves image resolution through the magnified virtual image of MLA. The MLA-assisted MCM successfully provides a clear, magnified image by integrating a pinhole mask to prevent image overlap without additional alignment. The magnification of MLA-assisted MCM was increased by 3.92 times compared with that of MCM, and the higher magnification mode demonstrates the image resolution of 2.46 μm. The compact portable microscope can provide a new platform for defect inspection or disease detection on site.
Collapse
|
6
|
Microscopic Imaging Methods for Organ-on-a-Chip Platforms. MICROMACHINES 2022; 13:mi13020328. [PMID: 35208453 PMCID: PMC8879989 DOI: 10.3390/mi13020328] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 02/15/2022] [Accepted: 02/15/2022] [Indexed: 02/06/2023]
Abstract
Microscopic imaging is essential and the most popular method for in situ monitoring and evaluating the outcome of various organ-on-a-chip (OOC) platforms, including the number and morphology of mammalian cells, gene expression, protein secretions, etc. This review presents an overview of how various imaging methods can be used to image organ-on-a-chip platforms, including transillumination imaging (including brightfield, phase-contrast, and holographic optofluidic imaging), fluorescence imaging (including confocal fluorescence and light-sheet fluorescence imaging), and smartphone-based imaging (including microscope attachment-based, quantitative phase, and lens-free imaging). While various microscopic imaging methods have been demonstrated for conventional microfluidic devices, a relatively small number of microscopic imaging methods have been demonstrated for OOC platforms. Some methods have rarely been used to image OOCs. Specific requirements for imaging OOCs will be discussed in comparison to the conventional microfluidic devices and future directions will be introduced in this review.
Collapse
|
7
|
Multi-frequency impedance sensing for detection and sizing of DNA fragments. Sci Rep 2021; 11:6490. [PMID: 33753781 PMCID: PMC7985362 DOI: 10.1038/s41598-021-85755-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Accepted: 01/11/2021] [Indexed: 01/31/2023] Open
Abstract
Electronic biosensors for DNA detection typically utilize immobilized oligonucleotide probes on a signal transducer, which outputs an electronic signal when target molecules bind to probes. However, limitation in probe selectivity and variable levels of non-target material in complex biological samples can lead to nonspecific binding and reduced sensitivity. Here we introduce the integration of 2.8 μm paramagnetic beads with DNA fragments. We apply a custom-made microfluidic chip to detect DNA molecules bound to beads by measuring Impedance Peak Response (IPR) at multiple frequencies. Technical and analytical performance was evaluated using beads containing purified Polymerase Chain Reaction (PCR) products of different lengths (157, 300, 613 bp) with DNA concentration ranging from 0.039 amol to 7.8 fmol. Multi-frequency IPR correlated positively with DNA amounts and was used to calculate a DNA quantification score. The minimum DNA amount of a 300 bp fragment coupled on beads that could be robustly detected was 0.0039 fmol (1.54 fg or 4750 copies/bead). Additionally, our approach allowed distinguishing beads with similar molar concentration DNA fragments of different lengths. Using this impedance sensor, purified PCR products could be analyzed within ten minutes to determine DNA fragment length and quantity based on comparison to a known DNA standard.
Collapse
|
8
|
Chen W, Yao Y, Chen T, Shen W, Tang S, Lee HK. Application of smartphone-based spectroscopy to biosample analysis: A review. Biosens Bioelectron 2020; 172:112788. [PMID: 33157407 DOI: 10.1016/j.bios.2020.112788] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Revised: 10/05/2020] [Accepted: 10/30/2020] [Indexed: 12/18/2022]
Abstract
The emergence of the smartphones has brought extensive changes to our lifestyles, from communicating with one another, to shopping and enjoyment of entertainment, and from studying to functioning at the workplace (and in the field). At the same time, this portable device has also provided new possibilities in scientific research and applications. Based on the growing awareness of good health management, researchers have coupled health monitoring to smartphone sensing technologies. Along the way, there have been developed a variety of smartphone-based optical detection platforms for analyzing biological samples, including standalone smartphone units and integrated smartphone sensing systems. In this review, we outline the applications of smartphone-based optical sensors for biosamples. These applications focus mainly on three aspects: Microscopic imaging sensing, colorimetric sensing and luminescence sensing. We also discuss briefly some limitations of the current state of smartphone-based spectroscopy and present prospects of the future applicability of smartphone sensors.
Collapse
Affiliation(s)
- Wenhui Chen
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China
| | - Yao Yao
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China
| | - Tianyu Chen
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China
| | - Wei Shen
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China
| | - Sheng Tang
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China.
| | - Hian Kee Lee
- Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore, 117543, Singapore; National University of Singapore Environmental Research Institute, T-Lab Building #02-01, 5A Engineering Drive 1, Singapore, 117411, Singapore; Tropical Marine Science Institute, National University of Singapore, S2S Building, 18 Kent Ridge Road, Singapore, 119227, Singapore.
| |
Collapse
|
9
|
Chen G, Chai HH, Fu JJ, Yu L, Fang C. A smartphone-supported portable micro-spectroscopy/imaging system to characterize morphology and spectra of samples at the microscale. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:4166-4171. [PMID: 32785298 DOI: 10.1039/d0ay00945h] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
A smartphone-based analysis system is favored for point-of-care testing applications. The present work proposes a novel micro-spectroscopy/imaging system comprising a portable spectrometer as an optical sensor and a compact homemade microscope to acquire the image and spectra of micron-scale regions. Protein concentration quantification based on the bicinchoninic acid method was demonstrated with the proposed micro-spectroscopy/imaging system to analyse the spectrometer signals. Morphologies of onion endothelial and human breast cancer cells, used as biological sample models, were characterized to demonstrate the microscopic imaging capacity of the device. The ability to simultaneously obtain morphological and spectral information using the proposed portable device was demonstrated by examining the 10 μm sub-pixels of a smartphone screen. These results highlight the potential for adopting a smartphone-based micro-spectroscopy/imaging system for point-of-care testing.
Collapse
Affiliation(s)
- Gang Chen
- Institute for Clean energy & Advanced Materials, School of Materials & Energy, Southwest University, Chongqing 400715, China.
| | - Hui Hui Chai
- Institute for Clean energy & Advanced Materials, School of Materials & Energy, Southwest University, Chongqing 400715, China.
| | - Jing Jing Fu
- Institute for Clean energy & Advanced Materials, School of Materials & Energy, Southwest University, Chongqing 400715, China.
| | - Ling Yu
- Institute for Clean energy & Advanced Materials, School of Materials & Energy, Southwest University, Chongqing 400715, China.
| | - Can Fang
- School of Computer and Information Science, Southwest University, Chongqing 400715, China.
| |
Collapse
|
10
|
Wang W, Liu H, Yu Y, Cong F, Yu J. Rapid Yeast Cell Viability Analysis by Using a Portable Microscope Based on the Fiber Optic Array and Simple Image Processing. SENSORS 2020; 20:s20072092. [PMID: 32276368 PMCID: PMC7180804 DOI: 10.3390/s20072092] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Revised: 04/02/2020] [Accepted: 04/05/2020] [Indexed: 12/20/2022]
Abstract
A fiber optic array (FOA) can be used as an alternative or a supplement to the lens in a microscope due to its large magnification, high coupling efficiency and extremely low distortion. Based on our previous research, this paper first demonstrated the resolution and field-of-view (FOV) of the microscope based on the FOA. To further validate the FOA microscope’s imaging capability, yeast activity and concentration were investigated by simple image processing. The results showed that the percentages of live and dead yeast cells correctly identified were 92.1% and 84.8%, except for the clusters, which agreed well with the manual counting methods. Then, the performances of the portable microscopes based on the FOA and lens were compared and the factors that affect the FOA microscope imaging performance were analyzed.
Collapse
Affiliation(s)
- Weiming Wang
- Faculty of Electronic Information and Electrical Engineering, Dalian University of Technology, No. 2 Linggong Road, Ganjingzi District, Dalian 116024, China; (W.W.); (H.L.); (Y.Y.); (F.C.)
- Key Laboratory of Integrated Circuit and Biomedical Electronic System of Liaoning Province, Dalian University of Technology, Dalian 116023, China
| | - Hang Liu
- Faculty of Electronic Information and Electrical Engineering, Dalian University of Technology, No. 2 Linggong Road, Ganjingzi District, Dalian 116024, China; (W.W.); (H.L.); (Y.Y.); (F.C.)
- Key Laboratory of Integrated Circuit and Biomedical Electronic System of Liaoning Province, Dalian University of Technology, Dalian 116023, China
| | - Yan Yu
- Faculty of Electronic Information and Electrical Engineering, Dalian University of Technology, No. 2 Linggong Road, Ganjingzi District, Dalian 116024, China; (W.W.); (H.L.); (Y.Y.); (F.C.)
- Key Laboratory of Integrated Circuit and Biomedical Electronic System of Liaoning Province, Dalian University of Technology, Dalian 116023, China
| | - Fengyu Cong
- Faculty of Electronic Information and Electrical Engineering, Dalian University of Technology, No. 2 Linggong Road, Ganjingzi District, Dalian 116024, China; (W.W.); (H.L.); (Y.Y.); (F.C.)
| | - Jun Yu
- Faculty of Electronic Information and Electrical Engineering, Dalian University of Technology, No. 2 Linggong Road, Ganjingzi District, Dalian 116024, China; (W.W.); (H.L.); (Y.Y.); (F.C.)
- Key Laboratory of Integrated Circuit and Biomedical Electronic System of Liaoning Province, Dalian University of Technology, Dalian 116023, China
- Correspondence:
| |
Collapse
|
11
|
Calabretta MM, Zangheri M, Lopreside A, Marchegiani E, Montali L, Simoni P, Roda A. Precision medicine, bioanalytics and nanomaterials: toward a new generation of personalized portable diagnostics. Analyst 2020; 145:2841-2853. [PMID: 32196042 DOI: 10.1039/c9an02041a] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
The customization of disease treatment focused on genetic, environmental and lifestyle factors of individual patients, including tailored medical decisions and treatments, is identified as precision medicine. This approach involves the combination of various aspects such as the collection and processing of a large amount of data, the selection of optimized and personalized drug dosage for each patient and the development of selective and reliable analytical tools for the monitoring of clinical, genetic and environmental parameters. In this context, miniaturized, compact and ultrasensitive bioanalytical devices play a crucial role for achieving the goals of personalized medicine. In this review, the latest analytical technologies suitable for providing portable and easy-to-use diagnostic tools in clinical settings will be discussed, highlighting new opportunities arising from nanotechnologies, offering peculiar perspectives and opportunities for precision medicine.
Collapse
Affiliation(s)
- Maria Maddalena Calabretta
- Department of Chemistry, Alma Mater Studiorum - University of Bologna, Via Selmi 2, 40126 Bologna, Italy.
| | | | | | | | | | | | | |
Collapse
|
12
|
Yang J, Wang K, Xu H, Yan W, Jin Q, Cui D. Detection platforms for point-of-care testing based on colorimetric, luminescent and magnetic assays: A review. Talanta 2019; 202:96-110. [PMID: 31171232 DOI: 10.1016/j.talanta.2019.04.054] [Citation(s) in RCA: 93] [Impact Index Per Article: 18.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 04/03/2019] [Accepted: 04/20/2019] [Indexed: 12/14/2022]
Abstract
Along with the considerable potential and increasing demand of the point-of-care testing (POCT), corresponding detection platforms have attracted great interest in both academic and practical fields. The first few generations of conventional detection devices tend to be costly, complicated to operate and hard to move on account of early limitations in the level of technological development and relatively high requirement of performance. Owing to the requirements for rapidity, simplicity, accuracy and cost controlling in the POCT, reader systems are urgently needed to be developed, upgraded and modified constantly, realizing on-site testing and healthcare management without a specific place or cumbersome operation. Accordingly, numerous rapid detection platforms with diverse size and performance have emerged such as bench-top apparatuses, handheld devices and intelligent detection devices. This review discusses various devices developed mainly for the detection of lateral flow test strips (LFTSs) or microfluidic strips in the POCT and summarizes these devices by size and portability. Furthermore, on the basis of various detection methods and diverse probes usually containing specific nanoparticles composites, three most common aspects of detection rationale in the POCT are selected to elaborate each kind of detection platforms in this paper: colorimetric assay, luminescent detection and magnetic signal detection. Herein, we focus on their structures, detection mechanisms and assay results, accompany with discussions and comments on the performances, costs and potential application, as well as advantages and limitations of each technique. In addition, perspectives on the future advances of detection platforms and some conclusions are proposed.
Collapse
Affiliation(s)
- Jinchuan Yang
- Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai Engineering Research Center for Intelligent diagnosis and treatment instrument, Key Laboratory of Thin Film and Microfabrication (Ministry of Education), Shanghai, 200240, PR China.
| | - Kan Wang
- Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai Engineering Research Center for Intelligent diagnosis and treatment instrument, Key Laboratory of Thin Film and Microfabrication (Ministry of Education), Shanghai, 200240, PR China.
| | - Hao Xu
- School of Naval Architecture, Ocean & Civil Engineering, Shanghai Jiao Tong University, Shanghai 200240, PR China.
| | - Wenqiang Yan
- Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai Engineering Research Center for Intelligent diagnosis and treatment instrument, Key Laboratory of Thin Film and Microfabrication (Ministry of Education), Shanghai, 200240, PR China.
| | - Qinghui Jin
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, PR China; Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo, 315211, PR China.
| | - Daxiang Cui
- Department of Instrument Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai Engineering Research Center for Intelligent diagnosis and treatment instrument, Key Laboratory of Thin Film and Microfabrication (Ministry of Education), Shanghai, 200240, PR China.
| |
Collapse
|
13
|
Pfeil J, Dangelat LN, Frohme M, Schulze K. Smartphone based mobile microscopy for diagnostics. ACTA ACUST UNITED AC 2019. [DOI: 10.3233/jcb-180010] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Juliane Pfeil
- Molecular Biology and Functional Genomics, Technical University of Applied Sciences Wildau, Germany
| | - Luise N. Dangelat
- Molecular Biology and Functional Genomics, Technical University of Applied Sciences Wildau, Germany
| | - Marcus Frohme
- Molecular Biology and Functional Genomics, Technical University of Applied Sciences Wildau, Germany
| | - Katja Schulze
- Oculyze GmbH, Mobile Microscopy and Computer Vision, Wildau, Germany
| |
Collapse
|
14
|
Yang K, Wu J, Santos S, Liu Y, Zhu L, Lin F. Recent development of portable imaging platforms for cell-based assays. Biosens Bioelectron 2019; 124-125:150-160. [DOI: 10.1016/j.bios.2018.10.024] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Revised: 10/06/2018] [Accepted: 10/13/2018] [Indexed: 12/22/2022]
|
15
|
Dutta S. Point of care sensing and biosensing using ambient light sensor of smartphone: Critical review. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2018.11.014] [Citation(s) in RCA: 62] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
16
|
Affiliation(s)
- Alexander C. Sun
- Electrical and Computer Engineering; University of California in; San Diego, La Jolla, CA
| | - Drew A. Hall
- Electrical and Computer Engineering; University of California in; San Diego, La Jolla, CA
| |
Collapse
|
17
|
Wang Y, Liu X, Chen P, Tran NT, Zhang J, Chia WS, Boujday S, Liedberg B. Smartphone spectrometer for colorimetric biosensing. Analyst 2018; 141:3233-8. [PMID: 27163736 DOI: 10.1039/c5an02508g] [Citation(s) in RCA: 71] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We report on a smartphone spectrometer for colorimetric biosensing applications. The spectrometer relies on a sample cell with an integrated grating substrate, and the smartphone's built-in light-emitting diode flash and camera. The feasibility of the smartphone spectrometer is demonstrated for detection of glucose and human cardiac troponin I, the latter in conjunction with peptide-functionalized gold nanoparticles.
Collapse
Affiliation(s)
- Yi Wang
- Centre for Biomimetic Sensor Science, School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Drive, 637553 Singapore. and Wenzhou Institute of Biomedical and Engineering, CNITECH, Chinese Academy of Sciences, Wenzhou, 325001, PR China
| | - Xiaohu Liu
- Centre for Biomimetic Sensor Science, School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Drive, 637553 Singapore.
| | - Peng Chen
- Centre for Biomimetic Sensor Science, School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Drive, 637553 Singapore.
| | - Nhung Thi Tran
- Centre for Biomimetic Sensor Science, School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Drive, 637553 Singapore.
| | - Jinling Zhang
- Centre for Biomimetic Sensor Science, School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Drive, 637553 Singapore.
| | - Wei Sheng Chia
- Centre for Biomimetic Sensor Science, School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Drive, 637553 Singapore.
| | - Souhir Boujday
- Centre for Biomimetic Sensor Science, School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Drive, 637553 Singapore. and Sorbonne Universités, UPMC Univ Paris 6, UMR CNRS 7197, Laboratoire de Réactivité de Surface, F75005 Paris, France
| | - Bo Liedberg
- Centre for Biomimetic Sensor Science, School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Drive, 637553 Singapore.
| |
Collapse
|
18
|
Abstract
Liquid crystal (LC) based optical sensors have been found to be very promising for detecting aqueous biological samples due to the ease of optical detection, their cost effectiveness and the removal of the need for labelling biological species with fluorescent dyes. To date, all LC based sensors are studied in laboratories using conventional polarizing optical microscopy (POM), and no attention has been paid towards the fabrication of portable LC sensing devices for use in commercial purposes. Here, we designed and fabricated a 3D printed portable, lightweight, and inexpensive sensing device using a smartphone to detect the optical signal of LC based sensors. The accuracy of the optical signal using the fabricated sensing device is similar to that obtained using conventional POM. The fabricated sensing device, using a smartphone, gives a novel and new platform to LC based sensors for practical applications in the industrial world and people's daily lives.
Collapse
Affiliation(s)
- Rajib Nandi
- Department of Chemical Sciences, Indian Institute of Science Education and Research (IISER) Mohali, Sector-81, Knowledge City, Manauli-140306, India.
| | | |
Collapse
|
19
|
Wang P, Kricka LJ. Current and Emerging Trends in Point-of-Care Technology and Strategies for Clinical Validation and Implementation. Clin Chem 2018; 64:1439-1452. [PMID: 29884677 DOI: 10.1373/clinchem.2018.287052] [Citation(s) in RCA: 64] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2018] [Accepted: 05/11/2018] [Indexed: 12/14/2022]
Abstract
BACKGROUND Point-of-care technology (POCT) provides actionable information at the site of care to allow rapid clinical decision-making. With healthcare emphasis shifting toward precision medicine, population health, and chronic disease management, the potential impact of POCT continues to grow, and several prominent POCT trends have emerged or strengthened in the last decade. CONTENT This review summarizes current and emerging trends in POCT, including technologies approved or cleared by the Food and Drug Administration or in development. Technologies included have either impacted existing clinical diagnostics applications (e.g., continuous monitoring and targeted nucleic acid testing) or are likely to impact diagnostics delivery in the near future. The focus is limited to in vitro diagnostics applications, although in some sections, technologies beyond in vitro diagnostics are also included given the commonalities (e.g., ultrasound plug-ins for smart phones). For technologies in development (e.g., wearables, noninvasive testing, mass spectrometry and nuclear magnetic resonance, paper-based diagnostics, nanopore-based devices, and digital microfluidics), we also discuss their potential clinical applications and provide perspectives on strategies beyond technological and analytical proof of concept, with the end goal of clinical implementation and impact. SUMMARY The field of POCT has witnessed strong growth over the past decade, as evidenced by new clinical or consumer products or research and development directions. Combined with the appropriate strategies for clinical needs assessment, validation, and implementation, these and future POCTs may significantly impact care delivery and associated outcomes and costs.
Collapse
Affiliation(s)
- Ping Wang
- William Pepper Laboratory, University of Pennsylvania Heath System, and the Department of Pathology and Laboratory Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA.
| | - Larry J Kricka
- William Pepper Laboratory, University of Pennsylvania Heath System, and the Department of Pathology and Laboratory Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA
| |
Collapse
|
20
|
Zarei M. Infectious pathogens meet point-of-care diagnostics. Biosens Bioelectron 2018; 106:193-203. [PMID: 29428589 DOI: 10.1016/j.bios.2018.02.007] [Citation(s) in RCA: 60] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2017] [Revised: 01/31/2018] [Accepted: 02/01/2018] [Indexed: 12/12/2022]
Abstract
The field of point-of-care (POC) diagnostics provides the rapid diagnosis of infectious diseases which is essential and critical for improving the general public health in resource-limited settings. POC platforms offer many advantages for detection of various pathogens including portability, automation, speed, cost, and efficiency. In this review, we provide an overview of the recent trends for POC diagnostics of infectious diseases with focus on portable platforms. We review here the present status of POC platforms, emphasizing in period of the past three years, then extrapolate their advance into the future applications for diagnosis of infectious pathogens.
Collapse
Affiliation(s)
- Mohammad Zarei
- Department of Chemical and Civil Engineering, University of Kurdistan, Sanandaj, P.O. Box 66177, Kurdistan Province 66618-36336, Iran.
| |
Collapse
|
21
|
Hohenstein J, O'Dell D, Murnane EL, Lu Z, Erickson D, Gay G. Enhancing the Usability of an Optical Reader System to Support Point-of-Care Rapid Diagnostic Testing: An Iterative Design Approach. JMIR Hum Factors 2017; 4:e29. [PMID: 29162559 PMCID: PMC5717447 DOI: 10.2196/humanfactors.8621] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2017] [Revised: 10/17/2017] [Accepted: 10/19/2017] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND In today's health care environment, increasing costs and inadequate medical resources have created a worldwide need for more affordable diagnostic tools that are also portable, fast, and easy to use. To address this issue, numerous research and commercial efforts have focused on developing rapid diagnostic technologies; however, the efficacy of existing systems has been hindered by usability problems or high production costs, making them infeasible for deployment in at-home, point-of-care (POC), or resource-limited settings. OBJECTIVE The aim of this study was to create a low-cost optical reader system that integrates with any smart device and accepts any type of rapid diagnostic test strip to provide fast and accurate data collection, sample analysis, and diagnostic result reporting. METHODS An iterative design methodology was employed by a multidisciplinary research team to engineer three versions of a portable diagnostic testing device that were evaluated for usability and overall user receptivity. RESULTS Repeated design critiques and usability studies identified a number of system requirements and considerations (eg, software compatibility, biomatter contamination, and physical footprint) that we worked to incrementally incorporate into successive system variants. Our final design phase culminated in the development of Tidbit, a reader that is compatible with any Wi-Fi-enabled device and test strip format. The Tidbit includes various features that support intuitive operation, including a straightforward test strip insertion point, external indicator lights, concealed electronic components, and an asymmetric shape, which inherently signals correct device orientation. Usability testing of the Tidbit indicates high usability for potential user communities. CONCLUSIONS This study presents the design process, specification, and user reception of the Tidbit, an inexpensive, easy-to-use, portable optical reader for fast, accurate quantification of rapid diagnostic test results. Usability testing suggests that the reader is usable among and can benefit a wide group of potential users, including in POC contexts. Generally, the methodology of this study demonstrates the importance of testing these types of systems with potential users and exemplifies how iterative design processes can be employed by multidisciplinary research teams to produce compelling technological solutions.
Collapse
Affiliation(s)
- Jess Hohenstein
- Department of Information Science, Cornell University, Ithaca, NY, United States
| | - Dakota O'Dell
- School of Applied and Engineering Physics, Cornell University, Ithaca, NY, United States
| | - Elizabeth L Murnane
- Department of Information Science, Cornell University, Ithaca, NY, United States
| | - Zhengda Lu
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, United States
| | - David Erickson
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY, United States
| | - Geri Gay
- Department of Information Science, Cornell University, Ithaca, NY, United States
| |
Collapse
|
22
|
Geng Z, Zhang X, Fan Z, Lv X, Su Y, Chen H. Recent Progress in Optical Biosensors Based on Smartphone Platforms. SENSORS 2017; 17:s17112449. [PMID: 29068375 PMCID: PMC5713127 DOI: 10.3390/s17112449] [Citation(s) in RCA: 91] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/19/2017] [Revised: 10/19/2017] [Accepted: 10/20/2017] [Indexed: 02/07/2023]
Abstract
With a rapid improvement of smartphone hardware and software, especially complementary metal oxide semiconductor (CMOS) cameras, many optical biosensors based on smartphone platforms have been presented, which have pushed the development of the point-of-care testing (POCT). Imaging-based and spectrometry-based detection techniques have been widely explored via different approaches. Combined with the smartphone, imaging-based and spectrometry-based methods are currently used to investigate a wide range of molecular properties in chemical and biological science for biosensing and diagnostics. Imaging techniques based on smartphone-based microscopes are utilized to capture microscale analysts, while spectrometry-based techniques are used to probe reactions or changes of molecules. Here, we critically review the most recent progress in imaging-based and spectrometry-based smartphone-integrated platforms that have been developed for chemical experiments and biological diagnosis. We focus on the analytical performance and the complexity for implementation of the platforms.
Collapse
Affiliation(s)
- Zhaoxin Geng
- School of Information Engineering, Minzu University of China, Beijing 100081, China.
| | - Xiong Zhang
- School of Information Engineering, Minzu University of China, Beijing 100081, China.
| | - Zhiyuan Fan
- State Key Laboratory for Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China.
| | - Xiaoqing Lv
- State Key Laboratory for Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China.
| | - Yue Su
- State Key Laboratory for Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China.
| | - Hongda Chen
- State Key Laboratory for Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China.
| |
Collapse
|
23
|
Bae JK, Vavilin A, You JS, Kim H, Ryu SY, Jang JH, Jung W. Smartphone-Based Endoscope System for Advanced Point-of-Care Diagnostics: Feasibility Study. JMIR Mhealth Uhealth 2017; 5:e99. [PMID: 28751302 PMCID: PMC5553006 DOI: 10.2196/mhealth.7232] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2017] [Revised: 05/16/2017] [Accepted: 06/02/2017] [Indexed: 11/24/2022] Open
Abstract
Background Endoscopic technique is often applied for the diagnosis of diseases affecting internal organs and image-guidance of surgical procedures. Although the endoscope has become an indispensable tool in the clinic, its utility has been limited to medical offices or operating rooms because of the large size of its ancillary devices. In addition, the basic design and imaging capability of the system have remained relatively unchanged for decades. Objective The objective of this study was to develop a smartphone-based endoscope system capable of advanced endoscopic functionalities in a compact size and at an affordable cost and to demonstrate its feasibility of point-of-care through human subject imaging. Methods We developed and designed to set up a smartphone-based endoscope system, incorporating a portable light source, relay-lens, custom adapter, and homebuilt Android app. We attached three different types of existing rigid or flexible endoscopic probes to our system and captured the endoscopic images using the homebuilt app. Both smartphone-based endoscope system and commercialized clinical endoscope system were utilized to compare the imaging quality and performance. Connecting the head-mounted display (HMD) wirelessly, the smartphone-based endoscope system could superimpose an endoscopic image to real-world view. Results A total of 15 volunteers who were accepted into our study were captured using our smartphone-based endoscope system, as well as the commercialized clinical endoscope system. It was found that the imaging performance of our device had acceptable quality compared with that of the conventional endoscope system in the clinical setting. In addition, images captured from the HMD used in the smartphone-based endoscope system improved eye-hand coordination between the manipulating site and the smartphone screen, which in turn reduced spatial disorientation. Conclusions The performance of our endoscope system was evaluated against a commercial system in routine otolaryngology examinations. We also demonstrated and evaluated the feasibility of conducting endoscopic procedures through a custom HMD.
Collapse
Affiliation(s)
- Jung Kweon Bae
- Ulsan National Institute of Science and Technology, Department of Biomedical Engineering, Ulsan, Republic Of Korea
| | - Andrey Vavilin
- Ulsan National Institute of Science and Technology, Department of Biomedical Engineering, Ulsan, Republic Of Korea
| | - Joon S You
- Ulsan National Institute of Science and Technology, Department of Biomedical Engineering, Ulsan, Republic Of Korea
| | - Hyeongeun Kim
- Ulsan National Institute of Science and Technology, Department of Biomedical Engineering, Ulsan, Republic Of Korea
| | - Seon Young Ryu
- Pohang University of Science and Technology, Creative IT Engineering, Pohang, Republic Of Korea
| | - Jeong Hun Jang
- Ajou University Hospital, Department of Otorhinolaryngology, Suwon, Republic Of Korea
| | - Woonggyu Jung
- Ulsan National Institute of Science and Technology, Department of Biomedical Engineering, Ulsan, Republic Of Korea
| |
Collapse
|
24
|
Mobile phone-based biosensing: An emerging “diagnostic and communication” technology. Biosens Bioelectron 2017; 92:549-562. [DOI: 10.1016/j.bios.2016.10.062] [Citation(s) in RCA: 178] [Impact Index Per Article: 25.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2016] [Revised: 10/04/2016] [Accepted: 10/23/2016] [Indexed: 01/02/2023]
|
25
|
Zarei M. Portable biosensing devices for point-of-care diagnostics: Recent developments and applications. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2017.04.001] [Citation(s) in RCA: 195] [Impact Index Per Article: 27.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
26
|
Dutta S, Saikia GP, Sarma DJ, Gupta K, Das P, Nath P. Protein, enzyme and carbohydrate quantification using smartphone through colorimetric digitization technique. JOURNAL OF BIOPHOTONICS 2017; 10:623-633. [PMID: 27243385 DOI: 10.1002/jbio.201500329] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2015] [Revised: 05/02/2016] [Accepted: 05/04/2016] [Indexed: 06/05/2023]
Abstract
In this paper the utilization of smartphone as a detection platform for colorimetric quantification of biological macromolecules has been demonstrated. Using V-channel of HSV color space, the quantification of BSA protein, catalase enzyme and carbohydrate (using D-glucose) have been successfully investigated. A custom designed android application has been developed for estimating the total concentration of biological macromolecules. The results have been compared with that of a standard spectrophotometer which is generally used for colorimetric quantification in laboratory settings by measuring its absorbance at a specific wavelength. The results obtained with the designed sensor is found to be similar when compared with the spectrophotometer data. The designed sensor is low cost, robust and we envision that it could promote diverse fields of bio-analytical investigations. Schematic illustration of the smartphone sensing mechanism for colorimetric analysis of biomolecular samples.
Collapse
Affiliation(s)
- Sibasish Dutta
- Applied Photonics and Nanophotonics Laboratory, Department of Physics, Tezpur University, Napaam, Assam, 784028, India
| | - Gunjan Prasad Saikia
- Department of Computer science, Guwahati University, Gopinath Bordoloi Nagar, Guwahati, Assam, 781014, India
| | - Dhruva Jyoti Sarma
- Applied Biochemistry Laboratory, Department of Molecular Biology and Biotechnology, Tezpur University, Napaam, Assam, 784028, India
| | - Kuldeep Gupta
- Applied Microbiology and Biotechnology Laboratory, Department of Molecular Biology and Biotechnology, Tezpur University, Napaam, Assam, 784028, India
| | - Priyanka Das
- Applied Photonics and Nanophotonics Laboratory, Department of Physics, Tezpur University, Napaam, Assam, 784028, India
| | - Pabitra Nath
- Applied Photonics and Nanophotonics Laboratory, Department of Physics, Tezpur University, Napaam, Assam, 784028, India
| |
Collapse
|
27
|
Streak Imaging Flow Cytometer for Rare Cell Analysis. Methods Mol Biol 2017. [PMID: 28281262 DOI: 10.1007/978-1-4939-6848-0_17] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
Abstract
There is a need for simple and affordable techniques for cytology for clinical applications, especially for point-of-care (POC) medical diagnostics in resource-poor settings. However, this often requires adapting expensive and complex laboratory-based techniques that often require significant power and are too massive to transport easily. One such technique is flow cytometry, which has great potential for modification due to the simplicity of the principle of optical tracking of cells. However, it is limited in that regard due to the flow focusing technique used to isolate cells for optical detection. This technique inherently reduces the flow rate and is therefore unsuitable for rapid detection of rare cells which require large volume for analysis.To address these limitations, we developed a low-cost, mobile flow cytometer based on streak imaging. In our new configuration we utilize a simple webcam for optical detection over a large area associated with a wide-field flow cell. The new flow cell is capable of larger volume and higher throughput fluorescence detection of rare cells than the flow cells with hydrodynamic focusing used in conventional flow cytometry. The webcam is an inexpensive, commercially available system, and for fluorescence analysis we use a 1 W 450 nm blue laser to excite Syto-9 stained cells with emission at 535 nm. We were able to detect low concentrations of stained cells at high flow rates of 10 mL/min, which is suitable for rapidly analyzing larger specimen volumes to detect rare cells at appropriate concentration levels. The new rapid detection capabilities, combined with the simplicity and low cost of this device, suggest a potential for clinical POC flow cytometry in resource-poor settings associated with global health.
Collapse
|
28
|
Compact, cost-effective and field-portable microscope prototype based on MISHELF microscopy. Sci Rep 2017; 7:43291. [PMID: 28233829 PMCID: PMC5324169 DOI: 10.1038/srep43291] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Accepted: 01/20/2017] [Indexed: 02/08/2023] Open
Abstract
We report on a reduced cost, portable and compact prototype design of lensless holographic microscope with an illumination/detection scheme based on wavelength multiplexing, working with single hologram acquisition and using a fast convergence algorithm for image processing. All together, MISHELF (initials coming from Multi-Illumination Single-Holographic-Exposure Lensless Fresnel) microscopy allows the recording of three Fresnel domain diffraction patterns in a single camera snap-shot incoming from illuminating the sample with three coherent lights at once. Previous implementations have proposed an illumination/detection procedure based on a tuned (illumination wavelengths centered at the maximum sensitivity of the camera detection channels) configuration but here we report on a detuned (non-centered ones) scheme resulting in prototype miniaturization and cost reduction. Thus, MISHELF microscopy in combination with a novel and fast iterative algorithm allows high-resolution (μm range) phase-retrieved (twin image elimination) quantitative phase imaging of dynamic events (video rate recording speed). The performance of this microscope prototype is validated through experiments using both amplitude (USAF resolution test) and complex (live swine sperm cells and flowing microbeads) samples. The proposed method becomes in an alternative instrument improving some capabilities of existing lensless microscopes.
Collapse
|
29
|
Roda A, Calabretta MM, Calabria D, Caliceti C, Cevenini L, Lopreside A, Zangheri M. Smartphone-Based Biosensors for Bioanalytics. PAST, PRESENT AND FUTURE CHALLENGES OF BIOSENSORS AND BIOANALYTICAL TOOLS IN ANALYTICAL CHEMISTRY: A TRIBUTE TO PROFESSOR MARCO MASCINI 2017. [DOI: 10.1016/bs.coac.2017.05.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
30
|
Ossandon M, Balsam J, Bruck HA, Kalpakis K, Rasooly A. A computational streak mode cytometry biosensor for rare cell analysis. Analyst 2017; 142:641-648. [DOI: 10.1039/c6an02517j] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Streak mode imaging flow cytometry for rare cell detection involves imaging moving fluorescently labeled cells in the video mode with a CCD camera.
Collapse
Affiliation(s)
- Miguel Ossandon
- National Cancer Institute
- Rockville
- USA
- University of Maryland Baltimore County
- USA
| | | | | | | | | |
Collapse
|
31
|
McLeod E, Ozcan A. Unconventional methods of imaging: computational microscopy and compact implementations. REPORTS ON PROGRESS IN PHYSICS. PHYSICAL SOCIETY (GREAT BRITAIN) 2016; 79:076001. [PMID: 27214407 DOI: 10.1088/0034-4885/79/7/076001] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
In the past two decades or so, there has been a renaissance of optical microscopy research and development. Much work has been done in an effort to improve the resolution and sensitivity of microscopes, while at the same time to introduce new imaging modalities, and make existing imaging systems more efficient and more accessible. In this review, we look at two particular aspects of this renaissance: computational imaging techniques and compact imaging platforms. In many cases, these aspects go hand-in-hand because the use of computational techniques can simplify the demands placed on optical hardware in obtaining a desired imaging performance. In the first main section, we cover lens-based computational imaging, in particular, light-field microscopy, structured illumination, synthetic aperture, Fourier ptychography, and compressive imaging. In the second main section, we review lensfree holographic on-chip imaging, including how images are reconstructed, phase recovery techniques, and integration with smart substrates for more advanced imaging tasks. In the third main section we describe how these and other microscopy modalities have been implemented in compact and field-portable devices, often based around smartphones. Finally, we conclude with some comments about opportunities and demand for better results, and where we believe the field is heading.
Collapse
Affiliation(s)
- Euan McLeod
- College of Optical Sciences, University of Arizona, Tucson, AZ 85721, USA
| | | |
Collapse
|
32
|
McCracken KE, Angus SV, Reynolds KA, Yoon JY. Multimodal Imaging and Lighting Bias Correction for Improved μPAD-based Water Quality Monitoring via Smartphones. Sci Rep 2016; 6:27529. [PMID: 27283336 PMCID: PMC4901345 DOI: 10.1038/srep27529] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2016] [Accepted: 05/16/2016] [Indexed: 01/06/2023] Open
Abstract
Smartphone image-based sensing of microfluidic paper analytical devices (μPADs) offers low-cost and mobile evaluation of water quality. However, consistent quantification is a challenge due to variable environmental, paper, and lighting conditions, especially across large multi-target μPADs. Compensations must be made for variations between images to achieve reproducible results without a separate lighting enclosure. We thus developed a simple method using triple-reference point normalization and a fast-Fourier transform (FFT)-based pre-processing scheme to quantify consistent reflected light intensity signals under variable lighting and channel conditions. This technique was evaluated using various light sources, lighting angles, imaging backgrounds, and imaging heights. Further testing evaluated its handle of absorbance, quenching, and relative scattering intensity measurements from assays detecting four water contaminants – Cr(VI), total chlorine, caffeine, and E. coli K12 – at similar wavelengths using the green channel of RGB images. Between assays, this algorithm reduced error from μPAD surface inconsistencies and cross-image lighting gradients. Although the algorithm could not completely remove the anomalies arising from point shadows within channels or some non-uniform background reflections, it still afforded order-of-magnitude quantification and stable assay specificity under these conditions, offering one route toward improving smartphone quantification of μPAD assays for in-field water quality monitoring.
Collapse
Affiliation(s)
- Katherine E McCracken
- Department of Agricultural &Biosystems Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Scott V Angus
- Department of Agricultural &Biosystems Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Kelly A Reynolds
- Mel and Enid Zuckerman College of Public Health, The University of Arizona, Tucson, Arizona 85721, United States
| | - Jeong-Yeol Yoon
- Department of Agricultural &Biosystems Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| |
Collapse
|
33
|
Roda A, Michelini E, Zangheri M, Di Fusco M, Calabria D, Simoni P. Smartphone-based biosensors: A critical review and perspectives. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2015.10.019] [Citation(s) in RCA: 331] [Impact Index Per Article: 41.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
34
|
Hutchison JR, Erikson RL, Sheen AM, Ozanich RM, Kelly RT. Reagent-free and portable detection of Bacillus anthracis spores using a microfluidic incubator and smartphone microscope. Analyst 2016; 140:6269-76. [PMID: 26266749 DOI: 10.1039/c5an01304f] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Bacillus anthracis is the causative agent of anthrax and can be contracted by humans and herbivorous mammals by inhalation, ingestion, or cutaneous exposure to bacterial spores. Due to its stability and disease potential, B. anthracis is a recognized biothreat agent and robust detection and viability methods are needed to identify spores from unknown samples. Here we report the use of smartphone-based microscopy (SPM) in combination with a simple microfluidic incubation device (MID) to detect 50 to 5000 B. anthracis Sterne spores in 3 to 5 hours. This technique relies on optical monitoring of the conversion of the ∼1 μm spores to the filamentous vegetative cells that range from tens to hundreds of micrometers in length. This distinguishing filament formation is unique to B. anthracis as compared to other members of the Bacillus cereus group. A unique feature of this approach is that the sample integrity is maintained, and the vegetative biomass can be removed from the chip for secondary molecular analysis such as PCR. Compared with existing chip-based and rapid viability PCR methods, this new approach reduces assay time by almost half, and is highly sensitive, specific, and cost effective.
Collapse
Affiliation(s)
- Janine R Hutchison
- Chemical Biological Signatures Science, National Security Directorate, Pacific Northwest National Laboratory, P. O. Box 999, Richland, Washington 99352, USA.
| | | | | | | | | |
Collapse
|
35
|
A Comparison of Classification Methods for Telediagnosis of Parkinson’s Disease. ENTROPY 2016. [DOI: 10.3390/e18040115] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
36
|
Abstract
High-resolution optical microscopy has traditionally relied on high-magnification and high-numerical aperture objective lenses. In contrast, lensless microscopy can provide high-resolution images without the use of any focusing lenses, offering the advantages of a large field of view, high resolution, cost-effectiveness, portability, and depth-resolved three-dimensional (3D) imaging. Here we review various approaches to lensless imaging, as well as its applications in biosensing, diagnostics, and cytometry. These approaches include shadow imaging, fluorescence, holography, superresolution 3D imaging, iterative phase recovery, and color imaging. These approaches share a reliance on computational techniques, which are typically necessary to reconstruct meaningful images from the raw data captured by digital image sensors. When these approaches are combined with physical innovations in sample preparation and fabrication, lensless imaging can be used to image and sense cells, viruses, nanoparticles, and biomolecules. We conclude by discussing several ways in which lensless imaging and sensing might develop in the near future.
Collapse
Affiliation(s)
- Aydogan Ozcan
- Department of Electrical Engineering.,Department of Bioengineering, and.,California NanoSystems Institute, University of California, Los Angeles, California 90095;
| | - Euan McLeod
- College of Optical Sciences, University of Arizona, Tucson, Arizona 85721;
| |
Collapse
|
37
|
Zhang D, Liu Q. Biosensors and bioelectronics on smartphone for portable biochemical detection. Biosens Bioelectron 2016; 75:273-84. [DOI: 10.1016/j.bios.2015.08.037] [Citation(s) in RCA: 439] [Impact Index Per Article: 54.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2015] [Revised: 08/01/2015] [Accepted: 08/18/2015] [Indexed: 01/12/2023]
|
38
|
Sickle cell detection using a smartphone. Sci Rep 2015; 5:15022. [PMID: 26492382 PMCID: PMC4615037 DOI: 10.1038/srep15022] [Citation(s) in RCA: 101] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2015] [Accepted: 09/16/2015] [Indexed: 12/20/2022] Open
Abstract
Sickle cell disease affects 25% of people living in Central and West Africa and, if left undiagnosed, can cause life threatening "silent" strokes and lifelong damage. However, ubiquitous testing procedures have yet to be implemented in these areas, necessitating a simple, rapid, and accurate testing platform to diagnose sickle cell disease. Here, we present a label-free, sensitive, and specific testing platform using only a small blood sample (<1 μl) based on the higher density of sickle red blood cells under deoxygenated conditions. Testing is performed with a lightweight and compact 3D-printed attachment installed on a commercial smartphone. This attachment includes an LED to illuminate the sample, an optical lens to magnify the image, and two permanent magnets for magnetic levitation of red blood cells. The sample is suspended in a paramagnetic medium with sodium metabisulfite and loaded in a microcapillary tube that is inserted between the magnets. Red blood cells are levitated in the magnetic field based on equilibrium between the magnetic and buoyancy forces acting on the cells. Using this approach, we were able to distinguish between the levitation patterns of sickle versus control red blood cells based on their degree of confinement.
Collapse
|
39
|
Dendere R, Myburg N, Douglas TS. A review of cellphone microscopy for disease detection. J Microsc 2015; 260:248-59. [PMID: 26372735 DOI: 10.1111/jmi.12307] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2015] [Accepted: 07/23/2015] [Indexed: 01/28/2023]
Abstract
The expansion in global cellphone network coverage coupled with advances in cellphone imaging capabilities present an opportunity for the advancement of cellphone microscopy as a low-cost alternative to conventional microscopy for disease detection in resource-limited regions. The development of cellphone microscopy has also benefitted from the availability of low-cost miniature microscope components such as low-power light-emitting diodes and ball lenses. As a result, researchers are developing hardware and software techniques that would enable such microscopes to produce high-resolution, diagnostic-quality images. This approach may lead to more widespread delivery of diagnostic services in resource-limited areas where there is a shortage of the skilled labour required for conventional microscopy and where prevalence of infectious and other diseases is still high. In this paper, we review current techniques, clinical applications and challenges faced in the field of cellphone microscopy.
Collapse
Affiliation(s)
- R Dendere
- MRC/UCT Medical Imaging Research Unit, Department of Human Biology, University of Cape Town, Cape Town, South Africa
| | - N Myburg
- MRC/UCT Medical Imaging Research Unit, Department of Human Biology, University of Cape Town, Cape Town, South Africa
| | - T S Douglas
- MRC/UCT Medical Imaging Research Unit, Department of Human Biology, University of Cape Town, Cape Town, South Africa
| |
Collapse
|
40
|
Balsam J, Bruck HA, Rasooly A. Webcam-based flow cytometer using wide-field imaging for low cell number detection at high throughput. Analyst 2015; 139:4322-9. [PMID: 24995370 DOI: 10.1039/c4an00669k] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Here we describe a novel low-cost flow cytometer based on a webcam capable of low cell number detection in a large volume which may overcome the limitations of current flow cytometry. Several key elements have been combined to yield both high throughput and high sensitivity. The first element is a commercially available webcam capable of 187 frames per second video capture at a resolution of 320 × 240 pixels. The second element in this design is a 1 W 450 nm laser module for area-excitation, which combined with the webcam allows for rapid interrogation of a flow field. The final element is a 2D flow-cell which overcomes the flow limitation of hydrodynamic focusing and allows for higher sample throughput in a wider flow field. This cell allows for the linear velocity of target cells to be lower than in a conventional "1D" hydrodynamic focusing flow-cells typically used in cytometry at similar volumetric flow rates. It also allows cells to be imaged at the full frame rate of the webcam. Using this webcam-based flow cytometer with wide-field imaging, it was confirmed that the detection of fluorescently tagged 5 μm polystyrene beads in "1D" hydrodynamic focusing flow-cells was not practical for low cell number detection due to streaking from the motion of the beads, which did not occur with the 2D flow-cell design. The sensitivity and throughput of this webcam-based flow cytometer was then investigated using THP-1 human monocytes stained with SYTO-9 florescent dye in the 2D flow-cell. The flow cytometer was found to be capable of detecting fluorescently tagged cells at concentrations as low as 1 cell per mL at flow rates of 500 μL min(-1) in buffer and in blood. The effectiveness of detection was concentration dependent: at 100 cells per mL 84% of the cells were detected compared to microscopy, 10 cells per mL 79% detected and 1 cell per mL 59% of the cells were detected. With the blood samples spiked to 100 cells per mL, the average concentration for all samples was 91.4 cells per mL, with a 95% confidence interval of 86-97 cells per mL. These low cell concentrations and the large volume capabilities of the system may overcome the limitations of current cytometry, and are applicable to rare cell (such as circulating tumor cell) detection The simplicity and low cost of this device suggests that it may have a potential use in developing point-of-care clinical flow cytometry for resource-poor settings associated with global health.
Collapse
Affiliation(s)
- Joshua Balsam
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993, USA
| | | | | |
Collapse
|
41
|
Medically relevant assays with a simple smartphone and tablet based fluorescence detection system. SENSORS 2015; 15:11653-64. [PMID: 26007723 PMCID: PMC4481933 DOI: 10.3390/s150511653] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Accepted: 05/17/2015] [Indexed: 12/12/2022]
Abstract
Cell phones and smart phones can be reconfigured as biomedical sensor devices but this requires specialized add-ons. In this paper we present a simple cell phone-based portable bioassay platform, which can be used with fluorescent assays in solution. The system consists of a tablet, a polarizer, a smart phone (camera) and a box that provides dark readout conditions. The assay in a well plate is placed on the tablet screen acting as an excitation source. A polarizer on top of the well plate separates excitation light from assay fluorescence emission enabling assay readout with a smartphone camera. The assay result is obtained by analysing the intensity of image pixels in an appropriate colour channel. With this device we carried out two assays, for collagenase and trypsin using fluorescein as the detected fluorophore. The results of collagenase assay with the lowest measured concentration of 3.75 µg/mL and 0.938 µg in total in the sample were comparable to those obtained by a microplate reader. The lowest measured amount of trypsin was 930 pg, which is comparable to the low detection limit of 400 pg for this assay obtained in a microplate reader. The device is sensitive enough to be used in point-of-care medical diagnostics of clinically relevant conditions, including arthritis, cystic fibrosis and acute pancreatitis.
Collapse
|
42
|
Zhu H, Ozcan A. Opto-fluidics based microscopy and flow cytometry on a cell phone for blood analysis. Methods Mol Biol 2015; 1256:171-90. [PMID: 25626539 DOI: 10.1007/978-1-4939-2172-0_12] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/20/2023]
Abstract
Blood analysis is one of the most important clinical tests for medical diagnosis. Flow cytometry and optical microscopy are widely used techniques to perform blood analysis and therefore cost-effective translation of these technologies to resource limited settings is critical for various global health as well as telemedicine applications. In this chapter, we review our recent progress on the integration of imaging flow cytometry and fluorescent microscopy on a cell phone using compact, light-weight and cost-effective opto-fluidic attachments integrated onto the camera module of a smartphone. In our cell-phone based opto-fluidic imaging cytometry design, fluorescently labeled cells are delivered into the imaging area using a disposable micro-fluidic chip that is positioned above the existing camera unit of the cell phone. Battery powered light-emitting diodes (LEDs) are butt-coupled to the sides of this micro-fluidic chip without any lenses, which effectively acts as a multimode slab waveguide, where the excitation light is guided to excite the fluorescent targets within the micro-fluidic chip. Since the excitation light propagates perpendicular to the detection path, an inexpensive plastic absorption filter is able to reject most of the scattered light and create a decent dark-field background for fluorescent imaging. With this excitation geometry, the cell-phone camera can record fluorescent movies of the particles/cells as they are flowing through the microchannel. The digital frames of these fluorescent movies are then rapidly processed to quantify the count and the density of the labeled particles/cells within the solution under test. With a similar opto-fluidic design, we have recently demonstrated imaging and automated counting of stationary blood cells (e.g., labeled white blood cells or unlabeled red blood cells) loaded within a disposable cell counting chamber. We tested the performance of this cell-phone based imaging cytometry and blood analysis platform by measuring the density of red and white blood cells as well as hemoglobin concentration in human blood samples, which showed a good match to our measurement results obtained using a commercially available hematology analyzer. Such a cell-phone enabled opto-fluidics microscopy, flow cytometry, and blood analysis platform could be especially useful for various telemedicine applications in remote and resource-limited settings.
Collapse
Affiliation(s)
- Hongying Zhu
- Electrical Engineering Department, University of California, Los Angeles, CA, 90095, USA,
| | | |
Collapse
|
43
|
Abstract
Flow cytometry is used for cell counting and analysis in numerous clinical and environmental applications. However flow cytometry is not used in mHealth mainly because current flow cytometers are large, expensive, power-intensive devices designed to operate in a laboratory. Their design results in a lack of portability and makes them unsuitable for mHealth applications. Another limitation of current technology is the low volumetric throughput rates that are not suitable for rapid detection of rare cells.To address these limitations, we describe here a novel, low-cost, mobile flow cytometer based on wide-field imaging with a webcam for large volume and high throughput fluorescence detection of rare cells as a simulation for circulating tumor cells (CTCs) detection. The mobile flow cytometer uses a commercially available webcam capable of 187 frames per second video capture at a resolution of 320 × 240 pixels. For fluorescence detection, a 1 W 450 nm blue laser is used for excitation of Syto-9 fluorescently stained cells detected at 535 nm. A wide-field flow cell was developed for large volume analysis that allows for the linear velocity of target cells to be lower than in conventional hydrodynamic focusing flow cells typically used in cytometry. The mobile flow cytometer was found to be capable of detecting low concentrations at flow rates of 500 μL/min, suitable for rare cell detection in large volumes. The simplicity and low cost of this device suggests that it may have a potential clinical use for mHealth flow cytometry for resource-poor settings associated with global health.
Collapse
Affiliation(s)
- Joshua Balsam
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD, 20993, USA
| | | | | |
Collapse
|
44
|
Yuan J, Zhao X, Wang X, Gu Z. Image decoding of photonic crystal beads array in the microfluidic chip for multiplex assays. Sci Rep 2014; 4:6755. [PMID: 25341876 PMCID: PMC4208063 DOI: 10.1038/srep06755] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2014] [Accepted: 10/03/2014] [Indexed: 12/15/2022] Open
Abstract
Along with the miniaturization and intellectualization of biomedical instruments, the increasing demand of health monitoring at anywhere and anytime elevates the need for the development of point of care testing (POCT). Photonic crystal beads (PCBs) as one kind of good encoded microcarriers can be integrated with microfluidic chips in order to realize cost-effective and high sensitive multiplex bioassays. However, there are difficulties in analyzing them towards automated analysis due to the characters of the PCBs and the unique detection manner. In this paper, we propose a strategy to take advantage of automated image processing for the color decoding of the PCBs array in the microfluidic chip for multiplex assays. By processing and alignment of two modal images of epi-fluorescence and epi-white light, every intact bead in the image is accurately extracted and decoded by PC colors, which stand for the target species. This method, which shows high robustness and accuracy under various configurations, eliminates the high hardware requirement of spectroscopy analysis and user-interaction software, and provides adequate supports for the general automated analysis of POCT based on PCBs array.
Collapse
Affiliation(s)
- Junjie Yuan
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
- Laboratory of Environment and Biosafety Research Institute of Southeast University in Suzhou, Suzhou 215123, China
| | - Xiangwei Zhao
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
- Laboratory of Environment and Biosafety Research Institute of Southeast University in Suzhou, Suzhou 215123, China
| | - Xiaoxia Wang
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
- Laboratory of Environment and Biosafety Research Institute of Southeast University in Suzhou, Suzhou 215123, China
| | - Zhongze Gu
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
- Laboratory of Environment and Biosafety Research Institute of Southeast University in Suzhou, Suzhou 215123, China
| |
Collapse
|
45
|
Cai D, Xiao M, Xu P, Xu YC, Du W. An integrated microfluidic device utilizing dielectrophoresis and multiplex array PCR for point-of-care detection of pathogens. LAB ON A CHIP 2014; 14:3917-3924. [PMID: 25082458 DOI: 10.1039/c4lc00669k] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
The early identification of causative pathogens in clinical specimens that require no cultivation is essential for directing evidence-based antimicrobial treatments in resource limited settings. Here, we describe an integrated microfluidic device for the rapid identification of pathogens in complex physiological matrices such as blood. The device was designed and fabricated using SlipChip technologies, which integrated four channels processing independent samples and identifying up to twenty different pathogens. Briefly, diluted whole human blood samples were directly injected into the device for analysis. The pathogens were extracted from the blood by dielectrophoresis, retained in an array of grooves, and identified by multiplex array PCR in nanoliter volumes with end-point fluorescence detection. The universality of the dielectrophoretic separation of pathogens from physiological fluids was evaluated with a panel of clinical isolates covering predominant bacterial and fungal species. Using this system, we simultaneously identified Pseudomonas aeruginosa, Staphylococcus aureus and Escherichia coli O157:H7 within 3 h. In addition to the prompt diagnosis of bloodstream infections, this method may also be utilized for differentiating microorganisms in contaminated water and environmental samples.
Collapse
Affiliation(s)
- Dongyang Cai
- State Key Laboratory of Microbial Resources, Institute of Microbiology, Chinese Academy of Sciences, 100101 Beijing, China.
| | | | | | | | | |
Collapse
|
46
|
Lee H, Xu L, Koh D, Nyayapathi N, Oh KW. Various on-chip sensors with microfluidics for biological applications. SENSORS 2014; 14:17008-36. [PMID: 25222033 PMCID: PMC4208211 DOI: 10.3390/s140917008] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/15/2014] [Revised: 08/29/2014] [Accepted: 09/10/2014] [Indexed: 12/29/2022]
Abstract
In this paper, we review recent advances in on-chip sensors integrated with microfluidics for biological applications. Since the 1990s, much research has concentrated on developing a sensing system using optical phenomena such as surface plasmon resonance (SPR) and surface-enhanced Raman scattering (SERS) to improve the sensitivity of the device. The sensing performance can be significantly enhanced with the use of microfluidic chips to provide effective liquid manipulation and greater flexibility. We describe an optical image sensor with a simpler platform for better performance over a larger field of view (FOV) and greater depth of field (DOF). As a new trend, we review consumer electronics such as smart phones, tablets, Google glasses, etc. which are being incorporated in point-of-care (POC) testing systems. In addition, we discuss in detail the current optical sensing system integrated with a microfluidic chip.
Collapse
Affiliation(s)
- Hun Lee
- Department of Electrical Engineering, University at Buffalo, State University of New York (SUNY at Buffalo), Buffalo, NY 14260, USA.
| | - Linfeng Xu
- Department of Electrical Engineering, University at Buffalo, State University of New York (SUNY at Buffalo), Buffalo, NY 14260, USA.
| | - Domin Koh
- Department of Electrical Engineering, University at Buffalo, State University of New York (SUNY at Buffalo), Buffalo, NY 14260, USA.
| | - Nikhila Nyayapathi
- Department of Electrical Engineering, University at Buffalo, State University of New York (SUNY at Buffalo), Buffalo, NY 14260, USA.
| | - Kwang W Oh
- Department of Electrical Engineering, University at Buffalo, State University of New York (SUNY at Buffalo), Buffalo, NY 14260, USA.
| |
Collapse
|
47
|
Wu TF, Yen TM, Han Y, Chiu YJ, Lin EYS, Lo YH. A light-sheet microscope compatible with mobile devices for label-free intracellular imaging and biosensing. LAB ON A CHIP 2014; 14:3341-8. [PMID: 24989638 DOI: 10.1039/c4lc00257a] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
The inner structure, especially the nuclear structure, of cells carries valuable information about disease and health conditions of a person. Here we demonstrate a label-free technique to enable direct observations and measurements of the size, shape and morphology of the cell nucleus. With a microfabricated lens and a commercial CMOS imager, we form a scanning light-sheet microscope to produce a dark-field optical scattering image of the cell nucleus that overlays with the bright-field image produced in a separate regime of the same CMOS sensor. We have used the device to detect nuclear features that characterize the life cycle of cells and have used the nucleus volume as a new parameter for cell classification. The device can be developed into a portable, low-cost, point-of-care device leveraging the capabilities of the CMOS imagers to be pervasive in mobile electronics.
Collapse
Affiliation(s)
- Tsung-Feng Wu
- Materials Science Program, University of California at San Diego, La Jolla, California 92093-0418, USA.
| | | | | | | | | | | |
Collapse
|
48
|
Ozcan A. Mobile phones democratize and cultivate next-generation imaging, diagnostics and measurement tools. LAB ON A CHIP 2014; 14:3187-94. [PMID: 24647550 PMCID: PMC4117730 DOI: 10.1039/c4lc00010b] [Citation(s) in RCA: 196] [Impact Index Per Article: 19.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
In this article, I discuss some of the emerging applications and the future opportunities and challenges created by the use of mobile phones and their embedded components for the development of next-generation imaging, sensing, diagnostics and measurement tools. The massive volume of mobile phone users, which has now reached ~7 billion, drives the rapid improvements of the hardware, software and high-end imaging and sensing technologies embedded in our phones, transforming the mobile phone into a cost-effective and yet extremely powerful platform to run, e.g., biomedical tests, and perform scientific measurements that would normally require advanced laboratory instruments. This rapidly evolving and continuing trend will help us transform how medicine, engineering and sciences are practiced and taught globally.
Collapse
Affiliation(s)
- Aydogan Ozcan
- Electrical Engineering Department, University of California, Los Angeles, CA 90095, USA.
| |
Collapse
|
49
|
Erickson D, O'Dell D, Jiang L, Oncescu V, Gumus A, Lee S, Mancuso M, Mehta S. Smartphone technology can be transformative to the deployment of lab-on-chip diagnostics. LAB ON A CHIP 2014; 14:3159-64. [PMID: 24700127 PMCID: PMC4117816 DOI: 10.1039/c4lc00142g] [Citation(s) in RCA: 103] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
The rapid expansion of mobile technology is transforming the biomedical landscape. By 2016 there will be 260 M active smartphones in the US and millions of health accessories and software "apps" running off them. In parallel with this have come major technical achievements in lab-on-a-chip technology leading to incredible new biochemical sensors and molecular diagnostic devices. Despite these advancements, the uptake of lab-on-a-chip technologies at the consumer level has been somewhat limited. We believe that the widespread availability of smartphone technology and the capabilities they offer in terms of computation, communication, social networking, and imaging will be transformative to the deployment of lab-on-a-chip type technology both in the developed and developing world. In this paper we outline why we believe this is the case, the new business models that may emerge, and detail some specific application areas in which this synergy will have long term impact, namely: nutrition monitoring and disease diagnostics in limited resource settings.
Collapse
Affiliation(s)
- David Erickson
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY 14853, USA.
| | | | | | | | | | | | | | | |
Collapse
|
50
|
Abstract
In this Review, we provide an overview of flatbed scanner based biomedical imaging and sensing techniques. The extremely large imaging field-of-view (e.g., ~600-700 cm(2)) of these devices coupled with their cost-effectiveness provide unique opportunities for digital imaging of samples that are too large for regular optical microscopes, and for collection of large amounts of statistical data in various automated imaging or sensing tasks. Here we give a short introduction to the basic features of flatbed scanners also highlighting the key parameters for designing scientific experiments using these devices, followed by a discussion of some of the significant examples, where scanner-based systems were constructed to conduct various biomedical imaging and/or sensing experiments. Along with mobile phones and other emerging consumer electronics devices, flatbed scanners and their use in advanced imaging and sensing experiments might help us transform current practices of medicine, engineering and sciences through democratization of measurement science and empowerment of citizen scientists, science educators and researchers in resource limited settings.
Collapse
Affiliation(s)
- Zoltán Göröcs
- Department of Electrical Engineering, University of California Los Angeles (UCLA Electrical Engineering and Bioengineering Departments), CA 90095, USA.
| | | |
Collapse
|