1
|
Wells SS, Bain IJ, Valenta AC, Lenhart AE, Steyer DJ, Kennedy RT. Microdialysis coupled with droplet microfluidics and mass spectrometry for determination of neurotransmitters in vivo with high temporal resolution. Analyst 2024; 149:2328-2337. [PMID: 38488040 PMCID: PMC11018092 DOI: 10.1039/d4an00112e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Accepted: 03/10/2024] [Indexed: 04/16/2024]
Abstract
Monitoring the concentration fluctuations of neurotransmitters in vivo is valuable for elucidating the chemical signals that underlie brain functions. Microdialysis sampling is a widely used tool for monitoring neurochemicals in vivo. The volume requirements of most techniques that have been coupled to microdialysis, such as HPLC, result in fraction collection times of minutes, thus limiting the temporal resolution possible. Further the time of analysis can become long for cases where many fractions are collected. Previously we have used direct analysis of dialysate by low-flow electrospray ionization-tandem mass spectrometry (ESI-MS/MS) on a triple quadrupole mass spectrometer to monitor acetylcholine, glutamate, and γ-amino-butyric acid to achieve multiplexed in vivo monitoring with temporal resolution of seconds. Here, we have expanded this approach to adenosine, dopamine, and serotonin. The method achieved limits of detection down to 2 nM, enabling basal concentrations of all these compounds, except serotonin, to be measured in vivo. Comparative analysis with LC-MS/MS showed accurate results for all compounds except for glutamate, possibly due to interference for this compound in vivo. Pairing this analysis with droplet microfluidics yields 11 s temporal resolution and can generate dialysate fractions down to 3 nL at rates up to 3 fractions per s from a microdialysis probe. The system is applied to multiplexed monitoring of neurotransmitter dynamics in response to stimulation by 100 mM K+ and amphetamine. These applications demonstrate the suitability of the droplet ESI-MS/MS method for monitoring short-term dynamics of up to six neurotransmitters simultaneously.
Collapse
Affiliation(s)
- Shane S Wells
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI 48109-1055, USA.
| | - Ian J Bain
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI 48109-1055, USA.
| | - Alec C Valenta
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI 48109-1055, USA.
| | - Ashley E Lenhart
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI 48109-1055, USA.
| | - Daniel J Steyer
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI 48109-1055, USA.
| | - Robert T Kennedy
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI 48109-1055, USA.
| |
Collapse
|
2
|
Cong XZ, Feng J, Zhang HJ, Zhang LZ, Lin TY, Chen G, Zhang ZL. Microfluidic Device-Based In Vivo Detection of PD-L1-Positive Small Extracellular Vesicles and Its Application for Tumor Monitoring. Anal Chem 2024; 96:2658-2665. [PMID: 38311857 DOI: 10.1021/acs.analchem.3c05418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2024]
Abstract
Liquid biopsy is of great significance in tumor early diagnosis and treatment stratification. PD-L1-positive small extracellular vesicles (PD-L1+ sEVs) are closely related to tumor growth and immunotherapy response, which are considered valuable liquid biopsy biomarkers. In contrast to conventional in vitro detection, in vivo detection has the ability to improve the detection efficiency and enable continuous or real-time dynamic monitoring. However, in vivo detection of PD-L1+ sEVs has multiple difficulties, such as high cell background, complex blood environments, and lack of a specific and stable detection method. Herein, the in vivo detection of PD-L1+ sEVs method was constructed, which efficiently separated sEVs based on the microfluidic device and quantitatively analyzed PD-L1+ sEVs by aptamer recognition and hybridization chain reaction. The concentration of PD-L1+ sEVs was continuously monitored, and significant differences at different stages of tumor as well as a correlation with tumor volume were found. Diseased and healthy individuals could also be effectively distinguished based on the concentration of PD-L1+ sEVs. The method with good stability, biocompatibility, and detection performance provided a powerful means for in vivo detection of PD-L1+ sEVs, contributing to the clinical diagnosis and treatment of tumor.
Collapse
Affiliation(s)
- Xi-Zhu Cong
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, P. R. China
| | - Jiao Feng
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, P. R. China
| | - He-Jing Zhang
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) and Key Laboratory of Oral Biomedicine of Ministry of Education, School and Hospital of Stomatology, Wuhan University, Wuhan 430079, P. R. China
| | - Lin-Zhou Zhang
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) and Key Laboratory of Oral Biomedicine of Ministry of Education, School and Hospital of Stomatology, Wuhan University, Wuhan 430079, P. R. China
| | - Tian-Yang Lin
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, P. R. China
| | - Gang Chen
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) and Key Laboratory of Oral Biomedicine of Ministry of Education, School and Hospital of Stomatology, Wuhan University, Wuhan 430079, P. R. China
| | - Zhi-Ling Zhang
- College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, P. R. China
| |
Collapse
|
3
|
Huang Y, Omorou M, Gao M, Mu C, Xu W, Xu H. Hydrogen sulfide and its donors for the treatment of cerebral ischaemia-reperfusion injury: A comprehensive review. Biomed Pharmacother 2023; 161:114506. [PMID: 36906977 DOI: 10.1016/j.biopha.2023.114506] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 03/06/2023] [Accepted: 03/07/2023] [Indexed: 03/12/2023] Open
Abstract
As an endogenous gas signalling molecule, hydrogen sulfide (H2S) is frequently present in a variety of mammals and plays a significant role in the cardiovascular and nervous systems. Reactive oxygen species (ROS) are produced in large quantities as a result of cerebral ischaemia-reperfusion, which is a very serious class of cerebrovascular diseases. ROS cause oxidative stress and induce specific gene expression that results in apoptosis. H2S reduces cerebral ischaemia-reperfusion-induced secondary injury via anti-oxidative stress injury, suppression of the inflammatory response, inhibition of apoptosis, attenuation of cerebrovascular endothelial cell injury, modulation of autophagy, and antagonism of P2X7 receptors, and it plays an important biological role in other cerebral ischaemic injury events. Despite the many limitations of the hydrogen sulfide therapy delivery strategy and the difficulty in controlling the ideal concentration, relevant experimental evidence demonstrating that H2S plays an excellent neuroprotective role in cerebral ischaemia-reperfusion injury (CIRI). This paper examines the synthesis and metabolism of the gas molecule H2S in the brain as well as the molecular mechanisms of H2S donors in cerebral ischaemia-reperfusion injury and possibly other unknown biological functions. With the active development in this field, it is expected that this review will assist researchers in their search for the potential value of hydrogen sulfide and provide new ideas for preclinical trials of exogenous H2S.
Collapse
Affiliation(s)
- Yiwei Huang
- Basic Medical College, Jiamusi University, Jiamusi 154007, Heilongjiang, China; Key Laboratory of Microecology-Immune Regulatory Network and Related Diseases, Jiamusi 154007, Heilongjiang, China.
| | - Moussa Omorou
- Key Laboratory of Microecology-Immune Regulatory Network and Related Diseases, Jiamusi 154007, Heilongjiang, China; Basic Medical College, Jiamusi University, Jiamusi 154007, Heilongjiang, China.
| | - Meng Gao
- Key Laboratory of Microecology-Immune Regulatory Network and Related Diseases, Jiamusi 154007, Heilongjiang, China; Basic Medical College, Jiamusi University, Jiamusi 154007, Heilongjiang, China.
| | - Chenxi Mu
- Key Laboratory of Microecology-Immune Regulatory Network and Related Diseases, Jiamusi 154007, Heilongjiang, China; Basic Medical College, Jiamusi University, Jiamusi 154007, Heilongjiang, China.
| | - Weijing Xu
- School of Public Health, Jiamusi University, Jiamusi 154007, Heilongjiang, China.
| | - Hui Xu
- Key Laboratory of Microecology-Immune Regulatory Network and Related Diseases, Jiamusi 154007, Heilongjiang, China.
| |
Collapse
|
4
|
Da Y, Luo S, Tian Y. Real-Time Monitoring of Neurotransmitters in the Brain of Living Animals. ACS APPLIED MATERIALS & INTERFACES 2023; 15:138-157. [PMID: 35394736 DOI: 10.1021/acsami.2c02740] [Citation(s) in RCA: 22] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Neurotransmitters, as important chemical small molecules, perform the function of neural signal transmission from cell to cell. Excess concentrations of neurotransmitters are often closely associated with brain diseases, such as Alzheimer's disease, depression, schizophrenia, and Parkinson's disease. On the other hand, the release of neurotransmitters under the induced stimulation indicates the occurrence of reward-related behaviors, including food and drug addiction. Therefore, to understand the physiological and pathological functions of neurotransmitters, especially in complex environments of the living brain, it is urgent to develop effective tools to monitor their dynamics with high sensitivity and specificity. Over the past 30 years, significant advances in electrochemical sensors and optical probes have brought new possibilities for studying neurons and neural circuits by monitoring the changes in neurotransmitters. This Review focuses on the progress in the construction of sensors for in vivo analysis of neurotransmitters in the brain and summarizes current attempts to address key issues in the development of sensors with high selectivity, sensitivity, and stability. Combined with the latest advances in technologies and methods, several strategies for sensor construction are provided for recording chemical signal changes in the complex environment of the brain.
Collapse
Affiliation(s)
- Yifan Da
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, Department of Chemistry, School of Chemistry and Molecular Engineering, East China Normal University, Dongchuan Road 500, Shanghai 200241, China
| | - Shihua Luo
- Department of Traumatology, Rui Jin Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200025, China
| | - Yang Tian
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, Department of Chemistry, School of Chemistry and Molecular Engineering, East China Normal University, Dongchuan Road 500, Shanghai 200241, China
| |
Collapse
|
5
|
Affiliation(s)
- Shuwen Cheng
- Renmin University of China Ringgold standard institution – Department of Chemistry Zhongguancun street 59th Beijing 100872 China
| | - Li Zhang
- Renmin University of China Ringgold standard institution – Department of Chemistry Zhongguancun street 59th Beijing 100872 China
| | - Meining Zhang
- Renmin University of China Ringgold standard institution – Department of Chemistry Zhongguancun street 59th Beijing 100872 China
| |
Collapse
|
6
|
Lee J, Jeong Y, Park S, Suh M, Lee Y. Development of an Electrochemical Dual H 2S/Ca 2+ Microsensor and Its In Vivo Application to a Rat Seizure Model. ACS Sens 2021; 6:4089-4097. [PMID: 34648260 DOI: 10.1021/acssensors.1c01612] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
A dual electrochemical microsensor was fabricated for concurrent monitoring of hydrogen sulfide (H2S) and calcium ions (Ca2+), which are closely linked important signaling species involved in various physiological processes. The dual sensor was prepared using a dual recessed electrode consisting of two platinum (Pt) microdisks (50 μm in diameter). Each electrode was individually optimized for the best sensing ability toward a target analyte. One electrode (WE1, amperometric H2S sensor) was modified with electrodeposition of Au and electropolymerized polyaniline coating. The other electrode (WE2, all-solid-state Ca2+-selective electrode) was composed of Ag/AgCl onto the recessed Pt disk formed via electrodeposition/chloridation, followed by silanization and Ca2+-selective membrane loading. The current of WE1 and the potential of WE2 in a dual sensor responded linearly to H2S concentration and logarithm of Ca2+ concentration, respectively, without a crosstalk between the sensing signals. Both WE1 and WE2 presented excellent sensitivity, selectivity (logKH2S,iAmp≤-3.5, i = CO, NO, O2, NO2-, AP, AA, DA, and GABA; and logKCa2+,jPot≤-3.2, j = Na+, K+, and Mg2+), and fast response time with reasonable stability (during ca. 6 h in vivo experiment). Particularly, WE2 prepared using a mixture of two ionophores (ETH1001 and ETH129) and two plasticizers (2-nitrophenyl octyl ether and bis(2-ethylhexyl) sebacate) showed a very shortened response time (tR to attain the ΔE/Δt slope of 0.6 mV/min = 3.0 ± 0.2 s, n ≥ 10), a critically required factor for real-time analysis. The developed sensor was utilized for simultaneous real-time monitoring of H2S and Ca2+ changes at the brain cortex surface of a living rat during spontaneous epileptic seizures induced by a cortical 4-aminopyridine injection. The dynamic changes of H2S and Ca2+ were clearly observed in an intimate correlation with the electrophysiological recording of seizures, demonstrating the sensor feasibility of in vivo and real-time simultaneous measurements of H2S and Ca2+.
Collapse
Affiliation(s)
- Jaeyoung Lee
- Department of Chemistry & Nanoscience, Ewha Womans University, Seoul 03760, Republic of Korea
| | - Yoonyi Jeong
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
| | - Subin Park
- Department of Chemistry & Nanoscience, Ewha Womans University, Seoul 03760, Republic of Korea
| | - Minah Suh
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
| | - Youngmi Lee
- Department of Chemistry & Nanoscience, Ewha Womans University, Seoul 03760, Republic of Korea
| |
Collapse
|
7
|
Brain neurochemical monitoring. Biosens Bioelectron 2021; 189:113351. [PMID: 34049083 DOI: 10.1016/j.bios.2021.113351] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Revised: 05/05/2021] [Accepted: 05/13/2021] [Indexed: 02/08/2023]
Abstract
Brain neurochemical monitoring aims to provide continuous and accurate measurements of brain biomarkers. It has enabled significant advances in neuroscience for application in clinical diagnostics, treatment, and prevention of brain diseases. Microfabricated electrochemical and optical spectroscopy sensing technologies have been developed for precise monitoring of brain neurochemicals. Here, a comprehensive review on the progress of sensing technologies developed for brain neurochemical monitoring is presented. The review provides a summary of the widely measured clinically relevant neurochemicals and commonly adopted recognition technologies. Recent advances in sampling, electrochemistry, and optical spectroscopy for brain neurochemical monitoring are highlighted and their application are discussed. Existing gaps in current technologies and future directions to design industry standard brain neurochemical sensing devices for clinical applications are addressed.
Collapse
|
8
|
Wang C, Wang M, Zhang W, Liu J, Lu M, Li K, Lin Y. Integrating Prussian Blue Analog-Based Nanozyme and Online Visible Light Absorption Approach for Continuous Hydrogen Sulfide Monitoring in Brains of Living Rats. Anal Chem 2019; 92:662-667. [PMID: 31834784 DOI: 10.1021/acs.analchem.9b04931] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The continuous detection of hydrogen sulfide (H2S) is significant for revealing its role in the neuron protection and diagnosis of various diseases. In this study, a Prussian blue analog nanocubes (PBA NCs)-based oxidase-like mimic was synthesized and designed for continuous H2S monitoring in a visible light absorption-based online optical detection platform (OODP). A specific chemical reaction between H2S and the PBA NCs induce a decreasing oxidase-like activity of the PBA NCs, generating lower amounts of oxidized products of 3,3'5,5'-tetramethylbenzidine (TMB) and increasing the light intensity. By coupling the microdialysis techniques with OODP, excellent linearity in the range of 0.1-20 μM H2S with a limit of detection of 33 nM and outstanding stability, reproducibility, and specificity in the response to H2S were exhibited. By using this OODP, near real-time response and continuous H2S measurements in the brains of living rats were successfully achieved. This new idea of integrating enzyme-like mimics with specific chemical reactions to form an online optical detection platform for continuous monitoring of neurochemical in the brain may be highly meaningful for thoroughly understanding the function of the brain.
Collapse
Affiliation(s)
- Chao Wang
- Department of Chemistry , Capital Normal University , 105 West Third Ring Road North , Haidian District, Beijing 100048 , China
| | - Manchao Wang
- Department of Chemistry , Capital Normal University , 105 West Third Ring Road North , Haidian District, Beijing 100048 , China
| | - Wang Zhang
- Department of Chemistry , Capital Normal University , 105 West Third Ring Road North , Haidian District, Beijing 100048 , China
| | - Jia Liu
- Department of Chemistry , Capital Normal University , 105 West Third Ring Road North , Haidian District, Beijing 100048 , China
| | - Mingju Lu
- Department of Chemistry , Capital Normal University , 105 West Third Ring Road North , Haidian District, Beijing 100048 , China
| | - Kai Li
- Department of Chemistry , Capital Normal University , 105 West Third Ring Road North , Haidian District, Beijing 100048 , China
| | - Yuqing Lin
- Department of Chemistry , Capital Normal University , 105 West Third Ring Road North , Haidian District, Beijing 100048 , China
| |
Collapse
|
9
|
Tang M, Xia HF, Xu CM, Feng J, Ren JG, Miao F, Wu M, Wu LL, Pang DW, Chen G, Zhang ZL. Magnetic Chip Based Extracorporeal Circulation: A New Tool for Circulating Tumor Cell in Vivo Detection. Anal Chem 2019; 91:15260-15266. [PMID: 31692331 DOI: 10.1021/acs.analchem.9b04286] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
In vivo detection of circulating tumor cells (CTCs) which inspect all of the circulating blood in body seems to have more advantages on cell capture, especially in earlier cancer diagnosis. Herein, based on in vivo microfluidic chip detection system (IV-chip-system), an extracorporeal circulation was constructed to effectively detect and monitor CTCs in vivo. Combined with microfluidic chip and immunomagnetic nanosphere (IMN), this system not only acts as a window for CTC monitoring but also serves as a collector for further cancer diagnosis and research on CTCs. Compared with the current in vivo detection method, this system can capture and detect CTCs in the bloodstream without any pretreatments, and it also has a higher CTC capture efficiency. It is worth mentioning that this system is stable and biocompatible without any irreversible damage to living animals. Taking use of this system, the mimicked CTC cleanup process in the blood vessel is monitored, which may open new insights in cancer research and early cancer diagnosis.
Collapse
Affiliation(s)
- Man Tang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences , Wuhan University , Wuhan 430072 , People's Republic of China
| | - Hou-Fu Xia
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) and Key Laboratory of Oral Biomedicine of Ministry of Education, School and Hospital of Stomatology , Wuhan University , Wuhan 430079 , People's Republic of China
| | - Chun-Miao Xu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences , Wuhan University , Wuhan 430072 , People's Republic of China
| | - Jiao Feng
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences , Wuhan University , Wuhan 430072 , People's Republic of China
| | - Jian-Gang Ren
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) and Key Laboratory of Oral Biomedicine of Ministry of Education, School and Hospital of Stomatology , Wuhan University , Wuhan 430079 , People's Republic of China
| | - Fan Miao
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) and Key Laboratory of Oral Biomedicine of Ministry of Education, School and Hospital of Stomatology , Wuhan University , Wuhan 430079 , People's Republic of China
| | - Min Wu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences , Wuhan University , Wuhan 430072 , People's Republic of China
| | - Ling-Ling Wu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences , Wuhan University , Wuhan 430072 , People's Republic of China
| | - Dai-Wen Pang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences , Wuhan University , Wuhan 430072 , People's Republic of China
| | - Gang Chen
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) and Key Laboratory of Oral Biomedicine of Ministry of Education, School and Hospital of Stomatology , Wuhan University , Wuhan 430079 , People's Republic of China
| | - Zhi-Ling Zhang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences , Wuhan University , Wuhan 430072 , People's Republic of China
| |
Collapse
|
10
|
Karunya R, Jayaprakash KS, Gaikwad R, Sajeesh P, Ramshad K, Muraleedharan KM, Dixit M, Thangaraj PR, Sen AK. Rapid measurement of hydrogen sulphide in human blood plasma using a microfluidic method. Sci Rep 2019; 9:3258. [PMID: 30824728 PMCID: PMC6397262 DOI: 10.1038/s41598-019-39389-7] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Accepted: 01/23/2019] [Indexed: 11/27/2022] Open
Abstract
Hydrogen sulfide (H2S) is emerging as an important gasotransmitter in both physiological and pathological states. Rapid measurement of H2S remains a challenge. We report a microfluidic method for rapid measurement of sulphide in blood plasma using Dansyl-Azide, a fluorescence (FL) based probe. We have measured known quantities of externally added (exogenous) H2S to both buffer and human blood plasma. Surprisingly, a decrease in FL intensity with increase in exogenous sulphide concentration in plasma was observed which is attributed to the interaction between the proteins and sulphide present in plasma underpinning our observation. The effects of mixing and incubation time, pH, and dilution of plasma on the FL intensity is studied which revealed that the FL assay required a mixing time of 2 min, incubation time of 5 min, a pH of 7.1 and performing the test within 10 min of sampling; these together constitute the optimal parameters at room temperature. A linear correlation (with R2 ≥ 0.95) and an excellent match was obtained when a comparison was done between the proposed microfluidic and conventional spectrofluorometric methods for known concentrations of H2S (range 0–100 µM). We have measured the baseline level of endogenous H2S in healthy volunteers which was found to lie in the range of 70 μM – 125 μM. The proposed microfluidic device with DNS-Az probe enables rapid and accurate estimation of a key gasotransmitter H2S in plasma in conditions closely mimicking real time clinical setting. The availability of this device as at the point of care, will help in understanding the role of H2S in health and disease.
Collapse
Affiliation(s)
- R Karunya
- Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, 600036, India
| | - K S Jayaprakash
- Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, 600036, India
| | - R Gaikwad
- Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, 600036, India
| | - P Sajeesh
- Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, 600036, India
| | - K Ramshad
- Department of Chemistry, Indian Institute of Technology Madras, Chennai, 600036, India
| | - K M Muraleedharan
- Department of Chemistry, Indian Institute of Technology Madras, Chennai, 600036, India
| | - M Dixit
- Department of Biotechnology, Indian Institute of Technology Madras, Chennai, 600036, India
| | - P R Thangaraj
- Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, 600036, India.,Department of Cardiothoracic Surgery, Apollo Hospital, Chennai, 600006, India
| | - A K Sen
- Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, 600036, India.
| |
Collapse
|
11
|
Wang S, Liu X, Zhang M. Reduction of Ammineruthenium(III) by Sulfide Enables In Vivo Electrochemical Monitoring of Free Endogenous Hydrogen Sulfide. Anal Chem 2017; 89:5382-5388. [DOI: 10.1021/acs.analchem.7b00069] [Citation(s) in RCA: 51] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Shujun Wang
- Department of Chemistry, Renmin University of China, Beijing 100872, China
| | - Xiaomeng Liu
- Department of Chemistry, Renmin University of China, Beijing 100872, China
| | - Meining Zhang
- Department of Chemistry, Renmin University of China, Beijing 100872, China
| |
Collapse
|
12
|
Ultrasensitive and facile electrochemical detection of hydrogen sulfide in rat brain microdialysate based on competitive binding reaction. Anal Bioanal Chem 2016; 409:1101-1107. [DOI: 10.1007/s00216-016-0030-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Revised: 10/04/2016] [Accepted: 10/12/2016] [Indexed: 12/12/2022]
|
13
|
Qian Q, Hao J, Ma W, Yu P, Mao L. Tuning interionic interaction by rationally controlling solution pH for highly selective colorimetric sensing of arginine. Anal Bioanal Chem 2016; 408:3005-12. [DOI: 10.1007/s00216-016-9323-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2015] [Revised: 12/26/2015] [Accepted: 01/11/2016] [Indexed: 10/22/2022]
|
14
|
DeLaMarre MF, Keyzer A, Shippy SA. Development of a simple droplet-based microfluidic capillary viscometer for low-viscosity Newtonian fluids. Anal Chem 2015; 87:4649-57. [PMID: 25825941 DOI: 10.1021/acs.analchem.5b00677] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Viscosity is an easily measured macroscopic property that provides molecular information and is widely used across the sciences and engineering. Here we report a microfluidic capillary viscometer that forms droplets from aqueous samples in an immiscible carrier phase and encodes information about sample viscosity in the droplet spacing. The device shows exceptional calibration stability, with only a 0.6% drift in calibration factor from run to run, the ability to handle aqueous and nonaqueous samples, and the ability to operate with sample volumes as low as 38 nL. Operating range for aqueous sample viscosity was characterized, and was found to be 0.96-52 cP. Operating range for aqueous shear rate was found to depend on aqueous viscosity and varied from 1.9 × 10(1)-4.4 × 10(2) s(-1) for high viscosity samples to 4.1 × 10(2)-6.0 × 10(3) s(-1) for low viscosity samples. Accuracy was tested by comparing measured viscosities of several samples including crème de menthe peppermint liquor, human urine, and baby oil to viscosities of the same samples obtained with a U-tube viscometer. The device was found to be very accurate, with differences between methods as low as 0.1%. The viscometer presented requires only a basic T junction and can utilize off-chip fluorescence to measure viscosity, which could allow for easy addition of viscometric measurement capabilities to existing droplet platforms. Furthermore, the device is capable of performing measurements on Newtonian fluids without precise control over pressures or flow rates, which significantly simplifies device operation.
Collapse
Affiliation(s)
- Michael F DeLaMarre
- Department of Chemistry, University of Illinois at Chicago, Illinois 60607, United States
| | - Alec Keyzer
- Department of Chemistry, University of Illinois at Chicago, Illinois 60607, United States
| | - Scott A Shippy
- Department of Chemistry, University of Illinois at Chicago, Illinois 60607, United States
| |
Collapse
|