1
|
Simonova MA, Ilgach DM, Kaskevich KI, Nepomnyashaya MI, Litvinova LS, Filippov AP, Yakimansky AV. Self-assembly of Polyfluorene Molecular Brushes with Poly(methacrylic acid) Side Chains in Ethanol and Water. POLYMER SCIENCE SERIES C 2022. [DOI: 10.1134/s181123822270014x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
2
|
Preparation of Ligand Brush Nanocapsules for Robust Self-Controlled Antimicrobial Activity with Low Cytotoxicity at Target pH and Humidity. Pharmaceutics 2022; 14:pharmaceutics14020280. [PMID: 35214011 PMCID: PMC8877937 DOI: 10.3390/pharmaceutics14020280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 01/17/2022] [Accepted: 01/19/2022] [Indexed: 11/21/2022] Open
Abstract
This study prepared nanocapsules (NCs) with excellent self-controlled antimicrobial activity at pH 6–7 and humidity 45–100%, conditions in which most bacterial and fungal strains thrive. The nanocapsule substrate (NC@SiO2) was 676 nm in diameter, and the ligand-grafted capsule (NC@SiO2-g-MAA) was 888 nm. The large surface area and outer ligand brush of the NCs induced a rapid, self-controlled antibacterial response in the pH and humidity conditions needed for industrial and medical applications. Ligand-brush NCs containing an anionic antimicrobial drug had a rapid release effect because of the repellent electrostatic force and swelling properties of the ligand brushes. Controlled release of the drug was achieved at pH 6 and humidity of 45% and 100%. As many carboxylic acid groups are deprotonated into carboxylic acids at pH 5, the NC@SiO2-g-MAA had a high negative charge density. Carboxylic acid groups are anionized (–COO−) at pH 6 and above and push each other out of the capsule, expanding the outer shell as in a polymer brush to create the release behavior. The surface potential of the NC intermediate (NC@SiO2-MPS) was −23.45 [mV], and the potential of the capsule surface decreased to −36.4 [mV] when the MAA ligand brushes were grafted onto the surface of the capsule intermediate. In an antimicrobial experiment using Escherichia coli, a clear zone of 13–20 mm formed at pH 6, and the E. coli was eradicated completely at pH 6 and pH 7 when the humidity was 100%.
Collapse
|
3
|
Novel Amphiphilic Polyfluorene-Graft-(Polymethacrylic Acid) Brushes: Synthesis, Conformation, and Self-Assembly. Polymers (Basel) 2021; 13:polym13244429. [PMID: 34960980 PMCID: PMC8708525 DOI: 10.3390/polym13244429] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 12/13/2021] [Accepted: 12/14/2021] [Indexed: 02/06/2023] Open
Abstract
Novel polyfluorene polymer brushes with polymethacrylic acid side chains were obtained by atom transfer radical polymerization (ATRP) and activator generated by electron transfer (AGET) ATRP of tert-butyl methacrylate on polyfluorene multifunctional macroinitiator, followed by protonolysis of the tert-butyl groups of the side chains. Kinetics of polymerization and molecular weights were fully characterized. These polymer brushes luminesce in the blue region of the spectrum with high quantum yields (0.64–0.77). It was shown that the luminescence intensity of polymer brushes is higher than the luminescence intensity of the macroinitiator (0.61). Moreover, due to their amphiphilic nature, they can form unimolecular micelles when an alcohol solution of the polymer brush is injected into water. These properties can potentially be used in drug delivery and bioimaging.
Collapse
|
4
|
Bao B, Su P, Zhu J, Chen J, Xu Y, Gu B, Liu Y, Wang L. Rapid aptasensor capable of simply detect tumor markers based on conjugated polyelectrolytes. Talanta 2018; 190:204-209. [PMID: 30172500 DOI: 10.1016/j.talanta.2018.07.072] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Revised: 07/18/2018] [Accepted: 07/22/2018] [Indexed: 01/08/2023]
Abstract
In this paper, a very simple, easily-operated and universal platform is proposed for tumor marker detection. In this strategy, tumor marker-specific aptamer, which can quench the fluorescence of polyfluorene-based cationic conjugated polyelectrolytes (PFN+), are used as recognizing probes. Upon addition of tumor marker, the aptamer can be assembled into the tumor marker-aptamer complex, resulting in fluorescence recovery of PFN+ and the detection of the targets. The most widely-used tumor markers, carcinoembryonic antigen (CEA) and fetoprotein (AFP) have been chosen as the model analytes for this work. The sensing method is capable of rapidly detect target protein within 5 min without complex handling procedure and expensive instruments. Compared with previous studies, the assay presented here is really simple and avoids either conjugated polyelectrolytes (CPEs) modification or oligonucleotide labeling. This method also shows a wide detection range of 3 orders of magnitude and the detection limit is 0.316 ng/mL for CEA and 1.76 ng/mL for AFP. Furthermore, the approach requires only a convenient"mix-and-detect" procedure and offers a universal platform for the sensitive detection of any target molecule of choice according to the selected aptamer.
Collapse
Affiliation(s)
- Biqing Bao
- Key Laboratory for Organic Electronics and Information Displays (KLOEID) & Institute of Advanced Materials (IAM) & Jiangsu Key Laboratory for Biosensors, Jiangsu National Synergistic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts and Telecommunications (NUPT), Nanjing 210023, Jiangsu, China
| | - Peng Su
- Key Laboratory for Organic Electronics and Information Displays (KLOEID) & Institute of Advanced Materials (IAM) & Jiangsu Key Laboratory for Biosensors, Jiangsu National Synergistic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts and Telecommunications (NUPT), Nanjing 210023, Jiangsu, China
| | - Jin Zhu
- Key Laboratory for Organic Electronics and Information Displays (KLOEID) & Institute of Advanced Materials (IAM) & Jiangsu Key Laboratory for Biosensors, Jiangsu National Synergistic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts and Telecommunications (NUPT), Nanjing 210023, Jiangsu, China
| | - Jia Chen
- Key Laboratory for Organic Electronics and Information Displays (KLOEID) & Institute of Advanced Materials (IAM) & Jiangsu Key Laboratory for Biosensors, Jiangsu National Synergistic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts and Telecommunications (NUPT), Nanjing 210023, Jiangsu, China
| | - Yu Xu
- Key Laboratory for Organic Electronics and Information Displays (KLOEID) & Institute of Advanced Materials (IAM) & Jiangsu Key Laboratory for Biosensors, Jiangsu National Synergistic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts and Telecommunications (NUPT), Nanjing 210023, Jiangsu, China
| | - Bingbing Gu
- Key Laboratory for Organic Electronics and Information Displays (KLOEID) & Institute of Advanced Materials (IAM) & Jiangsu Key Laboratory for Biosensors, Jiangsu National Synergistic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts and Telecommunications (NUPT), Nanjing 210023, Jiangsu, China
| | - Yunfei Liu
- Key Laboratory for Organic Electronics and Information Displays (KLOEID) & Institute of Advanced Materials (IAM) & Jiangsu Key Laboratory for Biosensors, Jiangsu National Synergistic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts and Telecommunications (NUPT), Nanjing 210023, Jiangsu, China
| | - Lianhui Wang
- Key Laboratory for Organic Electronics and Information Displays (KLOEID) & Institute of Advanced Materials (IAM) & Jiangsu Key Laboratory for Biosensors, Jiangsu National Synergistic Innovation Center for Advanced Materials (SICAM), Nanjing University of Posts and Telecommunications (NUPT), Nanjing 210023, Jiangsu, China.
| |
Collapse
|
5
|
Liu X, Hua X, Fan Q, Chao J, Su S, Huang YQ, Wang L, Huang W. Thioflavin T as an Efficient G-Quadruplex Inducer for the Highly Sensitive Detection of Thrombin Using a New Föster Resonance Energy Transfer System. ACS APPLIED MATERIALS & INTERFACES 2015; 7:16458-16465. [PMID: 26173915 DOI: 10.1021/acsami.5b03662] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
We report a new Föster resonance energy transfer (FRET) system that uses a special dye, thioflavin T (ThT), as an energy acceptor and a water-soluble conjugated polymer (CP) with high fluorescence as an energy donor. A simple, label-free, and sensitive strategy for the detection of thrombin in buffer and in diluted serum was designed based on this new system using ThT as an efficient inducer of the G-quadruplex. The difference between the blank and the positive samples was amplified due to distinctive FRET signals because thrombin has little effect on the intercalation of ThT into the G-quadruplex. In the absence of the target, ThT induces the aptamer to form a G-quadruplex and intercalates into it with strong fluorescence. The electrostatic attractions between the negatively charged G-quadruplex and positively charged CP allow a short donor-acceptor distance, resulting in a high FRET signal. However, in the presence of the target, the aptamer forms a G-quadruplex-thrombin complex first, followed by the intercalation of ThT into the G-quadruplex. A long distance exists between the donor and acceptor due to the strong steric hindrance from the large-sized thrombin, which leads to a low FRET signal. Compared with previously reported strategies based on the FRET between the CP and dye, our strategy is label-free, and the sensitivity was improved by an order of magnitude. Our strategy also shows the advantages of being simple, rapid (about 50 min), sensitive, label-free, and low-cost in comparison to strategies based on the FRET between quantum dots and dyes.
Collapse
|