1
|
Perfusion culture of endothelial cells under shear stress on microporous membrane in a pressure-driven microphysiological system. J Biosci Bioeng 2023; 135:79-85. [PMID: 36253250 DOI: 10.1016/j.jbiosc.2022.09.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 09/01/2022] [Accepted: 09/14/2022] [Indexed: 11/06/2022]
Abstract
This paper reports perfusion culture of human umbilical vein endothelial cells (HUVECs) on a microporous membrane in a pressure-driven microphysiological system (PD-MPS), which we developed previously as a multi-throughput perfusion culture platform. We designed fluidic culture unit with microporous membrane to culture HUVECs under fluidic shear stress and constructed a perfusion culture model in the PD-MPS platform. Four fluidic culture units were arranged in the microplate-sized device, which enables four-throughput assay for characterization of HUVECs under flow. Medium flow was generated above and below the membrane by sequential pneumatic pressure to apply physiological shear stress to HUVECs. HUVECs exhibited aligned morphology to the direction of the flow with shear stress of 11.5-17.7 dyn/cm2 under the flow condition, while they randomly aligned under static culture condition in a 6 well plate. We also observed 3.3- and 5.0-fold increase in the expression levels of the thrombomodulin and endothelial nitric oxide synthase mRNAs, respectively, under the flow condition in the PD-MPS compared to the static culture in 6 well plate. We also observed actin filament aligned to the direction of flow in HUVECs cultured under the flow condition.
Collapse
|
2
|
Zhang K, Ogando C, Filip A, Zhang T, Horton JA, Soman P. In vitromodel to study confined osteocyte networks exposed to flow-induced mechanical stimuli. Biomed Mater 2022; 17:10.1088/1748-605X/aca37c. [PMID: 36384043 PMCID: PMC10642715 DOI: 10.1088/1748-605x/aca37c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Accepted: 11/16/2022] [Indexed: 11/18/2022]
Abstract
Osteocytes are considered the primary mechanical sensor in bone tissue and orchestrate the coupled bone remodeling activity of adjacent osteoblast and osteoclast cells.In vivoinvestigation of mechanically induced signal propagation through networks of interconnected osteocytes is confounded by their confinement within the mineralized bone matrix, which cannot be modeled in conventional culture systems. In this study, we developed a new model that mimics thisin vivoconfinement using gelatin methacrylate (GelMA) hydrogel or GelMA mineralized using osteoblast-like model cells. This model also enables real-time optical examination of osteocyte calcium (Ca2+) signaling dynamics in response to fluid shear stimuli cultured under confined conditions. Using this system, we discovered several distinct and previously undescribed patterns of Ca2+responses that vary across networks of interconnected osteocytes as a function of space, time and connectivity. Heterogeneity in Ca2+signaling may provide new insights into bone remodeling in response to mechanical loading. Overall, such a model can be extended to study signaling dynamics within cell networks exposed to flow-induced mechanical stimuli under confined conditions.
Collapse
Affiliation(s)
- Kairui Zhang
- Department of Biomedical and Chemical Engineering, Syracuse University, Syracuse, NY, USA, 13244
- Syracuse Biomaterials Institute, Syracuse, NY, USA, 13244
| | - Courtney Ogando
- Department of Biomedical and Chemical Engineering, Syracuse University, Syracuse, NY, USA, 13244
- Syracuse Biomaterials Institute, Syracuse, NY, USA, 13244
| | - Alex Filip
- Department of Biomedical and Chemical Engineering, Syracuse University, Syracuse, NY, USA, 13244
- Syracuse Biomaterials Institute, Syracuse, NY, USA, 13244
| | - Teng Zhang
- Syracuse Biomaterials Institute, Syracuse, NY, USA, 13244
- Department of Mechanical and Aerospace Engineering, Syracuse University, Syracuse, NY, USA, 13244
| | - Jason A. Horton
- Syracuse Biomaterials Institute, Syracuse, NY, USA, 13244
- Dept. of Orthopedic Surgery, SUNY Upstate Medical University, Syracuse, NY, USA 13210
| | - Pranav Soman
- Department of Biomedical and Chemical Engineering, Syracuse University, Syracuse, NY, USA, 13244
- Syracuse Biomaterials Institute, Syracuse, NY, USA, 13244
| |
Collapse
|
3
|
Lourenço D, Lopes R, Pestana C, Queirós AC, João C, Carneiro EA. Patient-Derived Multiple Myeloma 3D Models for Personalized Medicine-Are We There Yet? Int J Mol Sci 2022; 23:12888. [PMID: 36361677 PMCID: PMC9657251 DOI: 10.3390/ijms232112888] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/19/2022] [Accepted: 10/22/2022] [Indexed: 12/03/2023] Open
Abstract
Despite the wide variety of existing therapies, multiple myeloma (MM) remains a disease with dismal prognosis. Choosing the right treatment for each patient remains one of the major challenges. A new approach being explored is the use of ex vivo models for personalized medicine. Two-dimensional culture or animal models often fail to predict clinical outcomes. Three-dimensional ex vivo models using patients' bone marrow (BM) cells may better reproduce the complexity and heterogeneity of the BM microenvironment. Here, we review the strengths and limitations of currently existing patient-derived ex vivo three-dimensional MM models. We analyze their biochemical and biophysical properties, molecular and cellular characteristics, as well as their potential for drug testing and identification of disease biomarkers. Furthermore, we discuss the remaining challenges and give some insight on how to achieve a more biomimetic and accurate MM BM model. Overall, there is still a need for standardized culture methods and refined readout techniques. Including both myeloma and other cells of the BM microenvironment in a simple and reproducible three-dimensional scaffold is the key to faithfully mapping and examining the relationship between these players in MM. This will allow a patient-personalized profile, providing a powerful tool for clinical and research applications.
Collapse
Affiliation(s)
- Diana Lourenço
- Myeloma Lymphoma Research Group—Champalimaud Experimental Clinical Research Programme of Champalimaud Foundation, 1400-038 Lisbon, Portugal
- Faculty of Medicine, University of Coimbra, 3000-548 Coimbra, Portugal
| | - Raquel Lopes
- Myeloma Lymphoma Research Group—Champalimaud Experimental Clinical Research Programme of Champalimaud Foundation, 1400-038 Lisbon, Portugal
- Faculty of Medicine, University of Lisbon, 1649-028 Lisbon, Portugal
| | - Carolina Pestana
- Myeloma Lymphoma Research Group—Champalimaud Experimental Clinical Research Programme of Champalimaud Foundation, 1400-038 Lisbon, Portugal
- Centre of Statistics and Its Applications, Faculty of Sciences, University of Lisbon, 1749-016 Lisbon, Portugal
| | - Ana C. Queirós
- Myeloma Lymphoma Research Group—Champalimaud Experimental Clinical Research Programme of Champalimaud Foundation, 1400-038 Lisbon, Portugal
| | - Cristina João
- Myeloma Lymphoma Research Group—Champalimaud Experimental Clinical Research Programme of Champalimaud Foundation, 1400-038 Lisbon, Portugal
- Faculty of Medical Sciences, NOVA Medical School, 1169-056 Lisbon, Portugal
- Hemato-Oncology Department of Champalimaud Foundation, 1400-038 Lisbon, Portugal
| | - Emilie Arnault Carneiro
- Myeloma Lymphoma Research Group—Champalimaud Experimental Clinical Research Programme of Champalimaud Foundation, 1400-038 Lisbon, Portugal
| |
Collapse
|
4
|
Sugiura S, Satoh T, Shin K, Onuki-Nagasaki R, Kanamori T. Perfusion culture of multi-layered HepG2 hepatocellular carcinoma cells in a pressure-driven microphysiological system. J Biosci Bioeng 2022; 134:348-355. [PMID: 35963667 DOI: 10.1016/j.jbiosc.2022.07.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 07/03/2022] [Accepted: 07/04/2022] [Indexed: 11/25/2022]
Abstract
Here we report the perfusion culture of a multi-layered tissue composed of HepG2 cells (a human hepatoma line) in a pressure-driven microphysiological system (PD-MPS), which we developed previously as a multi-throughput perfusion culture platform. The perfusion culture of multi-layered tissue model was constructed by inserting a modified commercially available permeable membrane insert into the PD-MPS. HepG2 cells were layered on the membrane, and culture medium was perfused both through and below the membrane. The seeded density (number of cells/cm2) of the culture model is 70 times that of static culture in a conventional 35-mm culture dish. Pressure-driven circulation of the medium in our compact device (8.6 × 7.0 × 4.5 cm3), which comprised two perfusion-culture modules and a pneumatic connection port, enabled perfusion culture of two multi-layered tissues (initially 1 × 105 cells). To obtain insight into the basic functionality of the multi-layered tissues as hepatocytes, we compared albumin production and urea synthesis between perfusion cultures and static cultures. The HepG2 cells grew and secreted increasing amounts of albumin throughout 20 days of perfusion culture, whereas albumin secretion did not increase under static culture conditions. In addition, on day 20, the amount of albumin secreted by the HepG2 cells in the microfluidic device was 68% of that in the conventional culture dish, which was seeded with the same number of cells but had a 70 times larger culture area. These features of high-density culture of functioning cells in a compact device support the application of PD-MPS in single- and multi-organ MPS.
Collapse
Affiliation(s)
- Shinji Sugiura
- Cellular and Molecular Biotechnology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Central 5th, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8565, Japan.
| | - Taku Satoh
- Cellular and Molecular Biotechnology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Central 5th, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8565, Japan; Stem Cell Evaluation Technology Research Association, Astellas Pharma, 21 Miyukigaoka, Tsukuba, Ibaraki 305-8585, Japan
| | - Kazumi Shin
- Cellular and Molecular Biotechnology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Central 5th, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8565, Japan
| | - Reiko Onuki-Nagasaki
- Cellular and Molecular Biotechnology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Central 5th, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8565, Japan; Stem Cell Evaluation Technology Research Association, Astellas Pharma, 21 Miyukigaoka, Tsukuba, Ibaraki 305-8585, Japan
| | - Toshiyuki Kanamori
- Cellular and Molecular Biotechnology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Central 5th, 1-1-1 Higashi, Tsukuba, Ibaraki 305-8565, Japan
| |
Collapse
|
5
|
Sui C, Zilberberg J, Lee W. Microfluidic device engineered to study the trafficking of multiple myeloma cancer cells through the sinusoidal niche of bone marrow. Sci Rep 2022; 12:1439. [PMID: 35087109 PMCID: PMC8795452 DOI: 10.1038/s41598-022-05520-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2021] [Accepted: 12/13/2021] [Indexed: 02/04/2023] Open
Abstract
Multiple myeloma (MM) is an incurable B cell malignancy characterized by the accumulation of monoclonal abnormal plasma cells in the bone marrow (BM). It has been a significant challenge to study the spatiotemporal interactions of MM cancer cells with the embedded microenvironments of BM. Here we report a microfluidic device which was designed to mimic several physiological features of the BM niche: (1) sinusoidal circulation, (2) sinusoidal endothelium, and (3) stroma. The endothelial and stromal compartments were constructed and used to demonstrate the device's utility by spatiotemporally characterizing the CXCL12-mediated egression of MM cells from the BM stroma and its effects on the barrier function of endothelial cells (ECs). We found that the egression of MM cells resulted in less organized and loosely connected ECs, the widening of EC junction pores, and increased permeability through ECs, but without significantly affecting the number density of viable ECs. The results suggest that the device can be used to study the physical and secreted factors determining the trafficking of cancer cells through BM. The sinusoidal flow feature of the device provides an integral element for further creating systemic models of cancers that reside or metastasize to the BM niche.
Collapse
Affiliation(s)
- Chao Sui
- Department of Chemical Engineering and Materials Science, Stevens Institute of Technology, 1 Castle Point on Hudson, Hoboken, NJ, 07030, USA
| | - Jenny Zilberberg
- Hackensack Meridian Health, Center for Discovery and Innovation, Nutley, NJ, 07110, USA
| | - Woo Lee
- Department of Chemical Engineering and Materials Science, Stevens Institute of Technology, 1 Castle Point on Hudson, Hoboken, NJ, 07030, USA. .,Department of Chemistry and Chemical Biology, Stevens Institute of Technology, 1 Castle Point On Hudson, Hoboken, NJ, 07030, USA.
| |
Collapse
|
6
|
Lin DSY, Rajasekar S, Marway MK, Zhang B. From Model System to Therapy: Scalable Production of Perfusable Vascularized Liver Spheroids in "Open-Top" 384-Well Plate. ACS Biomater Sci Eng 2020; 7:2964-2972. [PMID: 34275295 DOI: 10.1021/acsbiomaterials.0c00236] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Vasculature is a key component of many biological tissues and helps to regulate a wide range of biological processes. Modeling vascular networks or the vascular interface in organ-on-a-chip systems is an essential aspect of this technology. In many organ-on-a-chip devices, however, the engineered vasculatures are usually designed to be encapsulated inside closed microfluidic channels, making it difficult to physically access or extract the tissues for downstream applications and analysis. One unexploited benefit of tissue extraction is the potential of vascularizing, perfusing, and maturing the tissue in well-controlled, organ-on-a-chip microenvironments and then subsequently extracting that product for in vivo therapeutic implantation. Moreover, for both modeling and therapeutic applications, the scalability of the tissue production process is important. Here we demonstrate the scalable production of perfusable and extractable vascularized tissues in an "open-top" 384-well plate (referred to as IFlowPlate), showing that this system could be used to examine nanoparticle delivery to targeted tissues through the microvascular network and to model vascular angiogenesis. Furthermore, tissue spheroids, such as hepatic spheroids, can be vascularized in a scalable manner and then subsequently extracted for in vivo implantation. This simple multiple-well plate platform could not only improve the experimental throughputs of organ-on-a-chip systems but could potentially help expand the application of model systems to regenerative therapy.
Collapse
Affiliation(s)
- Dawn S Y Lin
- Department of Chemical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8, Canada
| | - Shravanthi Rajasekar
- Department of Chemical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8, Canada
| | - Mandeep Kaur Marway
- School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8, Canada
| | - Boyang Zhang
- Department of Chemical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8, Canada.,School of Biomedical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L8, Canada
| |
Collapse
|
7
|
Nasello G, Alamán-Díez P, Schiavi J, Pérez MÁ, McNamara L, García-Aznar JM. Primary Human Osteoblasts Cultured in a 3D Microenvironment Create a Unique Representative Model of Their Differentiation Into Osteocytes. Front Bioeng Biotechnol 2020; 8:336. [PMID: 32391343 PMCID: PMC7193048 DOI: 10.3389/fbioe.2020.00336] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Accepted: 03/26/2020] [Indexed: 01/12/2023] Open
Abstract
Microengineered systems provide an in vitro strategy to explore the variability of individual patient response to tissue engineering products, since they prefer the use of primary cell sources representing the phenotype variability. Traditional in vitro systems already showed that primary human osteoblasts embedded in a 3D fibrous collagen matrix differentiate into osteocytes under specific conditions. Here, we hypothesized that translating this environment to the organ-on-a-chip scale creates a minimal functional unit to recapitulate osteoblast maturation toward osteocytes and matrix mineralization. Primary human osteoblasts were seeded in a type I collagen hydrogel, to establish the role of lower (2.5 × 105 cells/ml) and higher (1 × 106 cells/ml) cell density on their differentiation into osteocytes. A custom semi-automatic image analysis software was used to extract quantitative data on cellular morphology from brightfield images. The results are showing that cells cultured at a high density increase dendrite length over time, stop proliferating, exhibit dendritic morphology, upregulate alkaline phosphatase (ALP) activity, and express the osteocyte marker dental matrix protein 1 (DMP1). On the contrary, cells cultured at lower density proliferate over time, do not upregulate ALP and express the osteoblast marker bone sialoprotein 2 (BSP2) at all timepoints. Our work reveals that microengineered systems create unique conditions to capture the major aspects of osteoblast differentiation into osteocytes with a limited number of cells. We propose that the microengineered approach is a functional strategy to create a patient-specific bone tissue model and investigate the individual osteogenic potential of the patient bone cells.
Collapse
Affiliation(s)
- Gabriele Nasello
- Multiscale in Mechanical and Biological Engineering (M2BE), University of Zaragoza, Zaragoza, Spain.,Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
| | - Pilar Alamán-Díez
- Multiscale in Mechanical and Biological Engineering (M2BE), University of Zaragoza, Zaragoza, Spain
| | - Jessica Schiavi
- Mechanobiology and Medical Device Research Group (MMDRG), National University of Ireland Galway, Galway, Ireland
| | - María Ángeles Pérez
- Multiscale in Mechanical and Biological Engineering (M2BE), University of Zaragoza, Zaragoza, Spain
| | - Laoise McNamara
- Mechanobiology and Medical Device Research Group (MMDRG), National University of Ireland Galway, Galway, Ireland
| | - José Manuel García-Aznar
- Multiscale in Mechanical and Biological Engineering (M2BE), University of Zaragoza, Zaragoza, Spain
| |
Collapse
|
8
|
Immunotherapeutics in Multiple Myeloma: How Can Translational Mouse Models Help? JOURNAL OF ONCOLOGY 2019; 2019:2186494. [PMID: 31093282 PMCID: PMC6481018 DOI: 10.1155/2019/2186494] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 12/28/2018] [Accepted: 03/04/2019] [Indexed: 12/30/2022]
Abstract
Multiple myeloma (MM) is usually diagnosed in older adults at the time of immunosenescence, a collection of age-related changes in the immune system that contribute to increased susceptibility to infection and cancer. The MM tumor microenvironment and cumulative chemotherapies also add to defects in immunity over the course of disease. In this review we discuss how mouse models have furthered our understanding of the immune defects caused by MM and enabled immunotherapeutics to progress to clinical trials, but also question the validity of using immunodeficient models for these purposes. Immunocompetent models, in particular the 5T series and Vk⁎MYC models, are increasingly being utilized in preclinical studies and are adding to our knowledge of not only the adaptive immune system but also how the innate system might be enhanced in anti-MM activity. Finally we discuss the concept of immune profiling to target patients who might benefit the most from immunotherapeutics, and the use of humanized mice and 3D culture systems for personalized medicine.
Collapse
|
9
|
Chen Z, He S, Zilberberg J, Lee W. Pumpless platform for high-throughput dynamic multicellular culture and chemosensitivity evaluation. LAB ON A CHIP 2019; 19:254-261. [PMID: 30547180 PMCID: PMC6333476 DOI: 10.1039/c8lc00872h] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
We report here a novel pumpless, 96-well plate-based platform for high-throughput dynamic multicellular culture and chemosensitivity evaluation. A gravity-driven flow strategy was developed to generate and sustain the flow rate of culture medium within 10% in the platform's 20 culture chambers. The ability of the platform to generate and sustain the medium flow was demonstrated by computational simulation, flow visualization, and ascertaining the previously known effect of flow-induced shear stress on the stimulated osteogenic differentiation of osteoblasts. The high-throughput utility of the platform was demonstrated by in situ cell staining and high content screening of chemosensitivity assays of multiple myeloma and osteoblast co-cultures. Endpoint characterization and data analyses for all 20 culture chambers required less than 1 hour.
Collapse
Affiliation(s)
- Zhehuan Chen
- Department of Chemical Engineering and Materials Science, Stevens Institute of Technology, 1 Castle Point on Hudson, Hoboken, New Jersey 07030, USA.
| | | | | | | |
Collapse
|
10
|
Tissue Engineering Platforms to Replicate the Tumor Microenvironment of Multiple Myeloma. Methods Mol Biol 2018; 1513:171-191. [PMID: 27807837 DOI: 10.1007/978-1-4939-6539-7_12] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023]
Abstract
We described here the manufacturing and implementation of two prototype perfusion culture devices designed primarily for the cultivation of difficult-to-preserve primary patient-derived multiple myeloma cells (MMC). The first device consists of an osteoblast (OSB)-derived 3D tissue scaffold constructed in a perfused microfluidic environment. The second platform is a 96-well plate-modified perfusion culture device that can be utilized to reconstruct several tissue and tumor microenvironments utilizing both primary human and murine cells. This culture device was designed and fabricated specifically to: (1) enable the preservation of primary MMC for downstream use in biological studies and chemosensitivity analyses and, (2) provide a high-throughput format that is compatible with plate readers specifically seeing that this system is built on an industry standard 96-well tissue culture plate.
Collapse
|
11
|
Sun Q, Choudhary S, Mannion C, Kissin Y, Zilberberg J, Lee WY. Ex vivo construction of human primary 3D-networked osteocytes. Bone 2017; 105:245-252. [PMID: 28942121 PMCID: PMC5690542 DOI: 10.1016/j.bone.2017.09.012] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2016] [Revised: 09/06/2017] [Accepted: 09/20/2017] [Indexed: 02/07/2023]
Abstract
A human bone tissue model was developed by constructing ex vivo the 3D network of osteocytes via the biomimetic assembly of primary human osteoblastic cells with 20-25μm microbeads and subsequent microfluidic perfusion culture. The biomimetic assembly: (1) enabled 3D-constructed cells to form cellular network via processes with an average cell-to-cell distance of 20-25μm, and (2) inhibited cell proliferation within the interstitial confine between the microbeads while the confined cells produced extracellular matrix (ECM) to form a mechanically integrated structure. The mature osteocytic expressions of SOST and FGF23 genes became significantly higher, especially for SOST by 250 folds during 3D culture. The results validate that the bone tissue model: (1) consists of 3D cellular network of primary human osteocytes, (2) mitigates the osteoblastic differentiation and proliferation of primary osteoblast-like cells encountered in 2D culture, and (3) therefore reproduces ex vivo the phenotype of human 3D-networked osteocytes. The 3D tissue construction approach is expected to provide a clinically relevant and high-throughput means for evaluating drugs and treatments that target bone diseases with in vitro convenience.
Collapse
Affiliation(s)
- Qiaoling Sun
- Department of Materials Science and Chemical Engineering, Stevens Institute of Technology, Hoboken, NJ, USA
| | - Saba Choudhary
- Department of Biomedical Engineering, Chemistry and Biological Sciences, Stevens Institute of Technology, Hoboken, NJ, USA
| | - Ciaran Mannion
- Department of Pathology, Hackensack University Medical Center, Hackensack, NJ, USA
| | - Yair Kissin
- Hackensack University Medical Center, Hackensack, NJ, USA
| | - Jenny Zilberberg
- Research Department, Hackensack University Medical Center, Hackensack, NJ, USA.
| | - Woo Y Lee
- Department of Materials Science and Chemical Engineering, Stevens Institute of Technology, Hoboken, NJ, USA.
| |
Collapse
|
12
|
Bersini S, Arrigoni C, Lopa S, Bongio M, Martin I, Moretti M. Engineered miniaturized models of musculoskeletal diseases. Drug Discov Today 2016; 21:1429-1436. [PMID: 27132520 DOI: 10.1016/j.drudis.2016.04.015] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2016] [Revised: 03/31/2016] [Accepted: 04/18/2016] [Indexed: 01/07/2023]
Abstract
The musculoskeletal system is an incredible machine that protects, supports and moves the human body. However, several diseases can limit its functionality, compromising patient quality of life. Designing novel pathological models would help to clarify the mechanisms driving such diseases, identify new biomarkers and screen potential drug candidates. Miniaturized models in particular can mimic the structure and function of basic tissue units within highly controlled microenvironments, overcoming the limitations of traditional macroscale models and complementing animal studies, which despite being closer to the in vivo situation, are affected by species-specific differences. Here, we discuss the miniaturized models engineered over the past few years to analyze osteochondral and skeletal muscle pathologies, demonstrating how the rationale design of novel systems could provide key insights into the pathological mechanisms behind diseases of the musculoskeletal system.
Collapse
Affiliation(s)
- Simone Bersini
- Cell and Tissue Engineering Lab, IRCCS Istituto Ortopedico Galeazzi, Milano, Italy
| | - Chiara Arrigoni
- Cell and Tissue Engineering Lab, IRCCS Istituto Ortopedico Galeazzi, Milano, Italy
| | - Silvia Lopa
- Cell and Tissue Engineering Lab, IRCCS Istituto Ortopedico Galeazzi, Milano, Italy
| | - Matilde Bongio
- Cell and Tissue Engineering Lab, IRCCS Istituto Ortopedico Galeazzi, Milano, Italy
| | - Ivan Martin
- Department of Surgery and Department of Biomedicine, University Hospital Basel, University of Basel, 4031 Basel, Switzerland
| | - Matteo Moretti
- Cell and Tissue Engineering Lab, IRCCS Istituto Ortopedico Galeazzi, Milano, Italy; Regenerative Medicine Technologies Lab, Ente Ospedaliero Cantonale (EOC), Lugano, Switzerland; Swiss Institute for Regenerative Medicine, Lugano, Switzerland; Fondazione Cardiocentro Ticino, Lugano, Switzerland.
| |
Collapse
|
13
|
Shemesh J, Jalilian I, Shi A, Heng Yeoh G, Knothe Tate ML, Ebrahimi Warkiani M. Flow-induced stress on adherent cells in microfluidic devices. LAB ON A CHIP 2015; 15:4114-27. [PMID: 26334370 DOI: 10.1039/c5lc00633c] [Citation(s) in RCA: 68] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Transduction of mechanical forces and chemical signals affect every cell in the human body. Fluid flow in systems such as the lymphatic or circulatory systems modulates not only cell morphology, but also gene expression patterns, extracellular matrix protein secretion and cell-cell and cell-matrix adhesions. Similar to the role of mechanical forces in adaptation of tissues, shear fluid flow orchestrates collective behaviours of adherent cells found at the interface between tissues and their fluidic environments. These behaviours range from alignment of endothelial cells in the direction of flow to stem cell lineage commitment. Therefore, it is important to characterize quantitatively fluid interface-dependent cell activity. Common macro-scale techniques, such as the parallel plate flow chamber and vertical-step flow methods that apply fluid-induced stress on adherent cells, offer standardization, repeatability and ease of operation. However, in order to achieve improved control over a cell's microenvironment, additional microscale-based techniques are needed. The use of microfluidics for this has been recognized, but its true potential has emerged only recently with the advent of hybrid systems, offering increased throughput, multicellular interactions, substrate functionalization on 3D geometries, and simultaneous control over chemical and mechanical stimulation. In this review, we discuss recent advances in microfluidic flow systems for adherent cells and elaborate on their suitability to mimic physiologic micromechanical environments subjected to fluid flow. We describe device design considerations in light of ongoing discoveries in mechanobiology and point to future trends of this promising technology.
Collapse
Affiliation(s)
- Jonathan Shemesh
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW 2052, Australia.
| | | | | | | | | | | |
Collapse
|