Kang YJ. Biomechanical Investigation of Red Cell Sedimentation Using Blood Shear Stress and Blood Flow Image in a Capillary Chip. MICROMACHINES 2023; 14:1594. [PMID: 37630130 PMCID: PMC10456426 DOI: 10.3390/mi14081594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Revised: 08/01/2023] [Accepted: 08/11/2023] [Indexed: 08/27/2023]
Abstract
Blood image intensity has been used to detect erythrocyte sedimentation rate (ESR). However, it does not give information on the biophysical properties of blood samples under continuous ESR. In this study, to quantify mechanical variations of blood under continuous ESR, blood shear stress and blood image intensity were obtained by analyzing blood flows in the capillary channel. A blood sample is loaded into a driving syringe to demonstrate the proposed method. The blood flow rate is set in a periodic on-off pattern. A blood sample is then supplied into a capillary chip, and microscopic blood images are captured at specific intervals. Blood shear stress is quantified from the interface of the bloodstream in the coflowing channel. τ0 is defined as the maximum shear stress obtained at the first period. Simultaneously, ESRτ is then obtained by analyzing temporal variations of blood shear stress for every on period. AII is evaluated by analyzing the temporal variation of blood image intensity for every off period. According to the experimental results, a shorter period of T = 4 min and no air cavity contributes to the high sensitivity of the two indices (ESRτ and AII). The τ0 exhibits substantial differences with respect to hematocrits (i.e., 30-50%) as well as diluents. The ESRτ and AII showed a reciprocal relationship with each other. Three suggested properties represented substantial differences for suspended blood samples (i.e., hardened red blood cells, different concentrations of dextran solution, and fibrinogen). In conclusion, the present method can detect variations in blood samples under continuous ESR effectively.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Republic of Korea
| |
Collapse
|
2
|
Luttikhuis N, Wiebe KS. Analyzing SDG interlinkages: identifying trade-offs and synergies for a responsible innovation. SUSTAINABILITY SCIENCE 2023; 18:1-19. [PMID: 37363308 PMCID: PMC10214325 DOI: 10.1007/s11625-023-01336-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Accepted: 04/17/2023] [Indexed: 06/28/2023]
Abstract
This paper responds to recent calls to address the indivisible nature of the Sustainable Development Goal (SDG) framework and the related knowledge gap on how SDG targets interlink with each other. It examines how SDG targets interact in the context of a specific technology, point of care (PoC) microfluidics, and how this relates to the concept of responsible innovation (RI). The novel SDG interlinkages methodology developed here involves several steps to filter the relevant interlinkages and a focus group of experts for discussing these interlinkages. The main findings indicate that several social synergies occur when deploying PoC microfluidics, but that the environmental trade-offs may jeopardize the total progress toward the SDGs. More specifically, the environmental sacrifices (use of plastics and lack of recyclability) resulted in the product being cheaper and, thus, better accessible. This work suggests that attention should be given (and prioritized) to the use of renewable and recyclable materials without jeopardizing the accessibility of the product. This should minimize the identified trade-offs. These findings inform how analyzing SDG interlinkages relates to the responsibilities and dimensions of RI in several ways. First, analyzing SDG interlinkages helps to execute the governance responsibility by using the RI dimensions (anticipation, reflexivity, inclusion and responsiveness). Second, analyzing SDG interlinkages gives insights into if and how a technology relates to the do-good and avoid-harm responsibility. This is important to assess the responsiveness of the technology to ensure that the technology can become truly sustainable and leaves no one behind.
Collapse
Affiliation(s)
- Nikki Luttikhuis
- Sustainable Energy Technology, SINTEF, Torgarden, P.O. Box 4760, 7465 Trondheim, Norway
- Department of Industrial Economics and Technology Management, Norwegian University of Science and Technology (NTNU), 7491 Trondheim, Norway
| | - Kirsten S. Wiebe
- Sustainable Energy Technology, SINTEF, Torgarden, P.O. Box 4760, 7465 Trondheim, Norway
| |
Collapse
|
3
|
Higuchi M, Watanabe N. Determination of the erythrocyte sedimentation rate using the hematocrit-corrected aggregation index and mean corpuscular volume. J Clin Lab Anal 2023; 37:e24877. [PMID: 37003619 PMCID: PMC10156103 DOI: 10.1002/jcla.24877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 02/17/2023] [Accepted: 03/19/2023] [Indexed: 04/03/2023] Open
Abstract
BACKGROUND Determination of the erythrocyte sedimentation rate (ESR) by measurement of erythrocyte aggregation is an alternative to the Westergren method and can be performed rapidly. However, its principle is opaque and the ESR values obtained can deviate from Westergren method values (WG ESR) due to hematocrit. Furthermore, WG ESR is affected by particle size, but no studies have examined the effect of individual mean corpuscular volumes (MCVs). METHODS Simultaneous measurement of the erythrocyte aggregation index (AI) over a 5-s interval and determination of the complete blood count in 80 μL blood from 203 patients were performed (hematocrit, 21.4%-52.3%; MCV, 62.7-114.1 fL). ESR values were calculated with the hematocrit-corrected AI (HAI) for comparison with WG ESR. We improved the calculation formula by using MCV. RESULTS The sedimentation velocity of a single erythrocyte in the samples agreed well with an exponential function of HAI. ESR values calculated using HAI showed excellent correlation with WG ESR (r = 0.899, p < 0.001; Bland-Altman analysis: bias 2.76, limits of agreement (LOA) -24.5 to 30.0), but the difference between the calculated ESR and WG ESR increased with decreasing MCV. Calculation of ESR considering both HAI and MCV eliminated the MCV-dependent deviation and improved the correlation with WG ESR (r = 0.920, p < 0.001, bias -2.17, LOA -24.6 to 20.3). CONCLUSION Calculation using HAI and MCV can rapidly provide ESR values that are highly correlated with WG ESR in clinical specimens over a wide range of hematocrit and MCV values.
Collapse
Affiliation(s)
- Makoto Higuchi
- Functional Control Systems Course, Graduate School of Engineering and Science, Shibaura Institute of Technology, Saitama, Japan
- Ogino Memorial Laboratory, Nihon Kohden Corporation, Saitama, Japan
| | - Nobuo Watanabe
- Functional Control Systems Course, Graduate School of Engineering and Science, Shibaura Institute of Technology, Saitama, Japan
| |
Collapse
|
4
|
Kang YJ. Biomechanical Assessment of Red Blood Cells in Pulsatile Blood Flows. MICROMACHINES 2023; 14:317. [PMID: 36838017 PMCID: PMC9958583 DOI: 10.3390/mi14020317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 01/24/2023] [Accepted: 01/24/2023] [Indexed: 06/18/2023]
Abstract
As rheological properties are substantially influenced by red blood cells (RBCs) and plasma, the separation of their individual contributions in blood is essential. The estimation of multiple rheological factors is a critical issue for effective early detection of diseases. In this study, three rheological properties (i.e., viscoelasticity, RBC aggregation, and blood junction pressure) are measured by analyzing the blood velocity and image intensity in a microfluidic device. Using a single syringe pump, the blood flow rate sets to a pulsatile flow pattern (Qb[t] = 1 + 0.5 sin(2πt/240) mL/h). Based on the discrete fluidic circuit model, the analytical formula of the time constant (λb) as viscoelasticity is derived and obtained at specific time intervals by analyzing the pulsatile blood velocity. To obtain RBC aggregation by reducing blood velocity substantially, an air compliance unit (ACU) is used to connect polyethylene tubing (i.d. = 250 µm, length = 150 mm) to the blood channel in parallel. The RBC aggregation index (AI) is obtained by analyzing the microscopic image intensity. The blood junction pressure (β) is obtained by integrating the blood velocity within the ACU. As a demonstration, the present method is then applied to detect either RBC-aggregated blood with different concentrations of dextran solution or hardened blood with thermally shocked RBCs. Thus, it can be concluded that the present method has the ability to consistently detect differences in diluent or RBCs in terms of three rheological properties.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Republic of Korea
| |
Collapse
|
5
|
Grigorev GV, Lebedev AV, Wang X, Qian X, Maksimov GV, Lin L. Advances in Microfluidics for Single Red Blood Cell Analysis. BIOSENSORS 2023; 13:117. [PMID: 36671952 PMCID: PMC9856164 DOI: 10.3390/bios13010117] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/04/2022] [Accepted: 12/23/2022] [Indexed: 05/24/2023]
Abstract
The utilizations of microfluidic chips for single RBC (red blood cell) studies have attracted great interests in recent years to filter, trap, analyze, and release single erythrocytes for various applications. Researchers in this field have highlighted the vast potential in developing micro devices for industrial and academia usages, including lab-on-a-chip and organ-on-a-chip systems. This article critically reviews the current state-of-the-art and recent advances of microfluidics for single RBC analyses, including integrated sensors and microfluidic platforms for microscopic/tomographic/spectroscopic single RBC analyses, trapping arrays (including bifurcating channels), dielectrophoretic and agglutination/aggregation studies, as well as clinical implications covering cancer, sepsis, prenatal, and Sickle Cell diseases. Microfluidics based RBC microarrays, sorting/counting and trapping techniques (including acoustic, dielectrophoretic, hydrodynamic, magnetic, and optical techniques) are also reviewed. Lastly, organs on chips, multi-organ chips, and drug discovery involving single RBC are described. The limitations and drawbacks of each technology are addressed and future prospects are discussed.
Collapse
Affiliation(s)
- Georgii V. Grigorev
- Data Science and Information Technology Research Center, Tsinghua Berkeley Shenzhen Institute, Tsinghua University, Shenzhen 518055, China
- Mechanical Engineering Department, University of California in Berkeley, Berkeley, CA 94720, USA
- School of Information Technology, Cherepovets State University, 162600 Cherepovets, Russia
| | - Alexander V. Lebedev
- Machine Building Department, Bauman Moscow State University, 105005 Moscow, Russia
| | - Xiaohao Wang
- Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - Xiang Qian
- Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - George V. Maksimov
- Faculty of Biology, Lomonosov Moscow State University, 119991 Moscow, Russia
- Physical metallurgy Department, Federal State Autonomous Educational Institution of Higher Education National Research Technological University “MISiS”, 119049 Moscow, Russia
| | - Liwei Lin
- Mechanical Engineering Department, University of California in Berkeley, Berkeley, CA 94720, USA
| |
Collapse
|
6
|
Kang YJ. Biosensing of Haemorheological Properties Using Microblood Flow Manipulation and Quantification. SENSORS (BASEL, SWITZERLAND) 2022; 23:408. [PMID: 36617006 PMCID: PMC9823650 DOI: 10.3390/s23010408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 12/26/2022] [Accepted: 12/27/2022] [Indexed: 06/17/2023]
Abstract
The biomechanical properties of blood have been used to detect haematological diseases and disorders. The simultaneous measurement of multiple haemorheological properties has been considered an important aspect for separating the individual contributions of red blood cells (RBCs) and plasma. In this study, three haemorheological properties (viscosity, time constant, and RBC aggregation) were obtained by analysing blood flow, which was set to a square-wave profile (steady and transient flow). Based on a simplified differential equation derived using a discrete circuit model, the time constant for viscoelasticity was obtained by solving the governing equation rather than using the curve-fitting technique. The time constant (λ) varies linearly with respect to the interface in the coflowing channel (β). Two parameters (i.e., average value: <λ>, linear slope: dλdβ) were newly suggested to effectively represent linearly varying time constant. <λ> exhibited more consistent results than dλdβ. To detect variations in the haematocrit in blood, we observed that the blood viscosity (i.e., steady flow) is better than the time constant (i.e., transient flow). The blood viscosity and time constant exhibited significant differences for the hardened RBCs. The present method was then successfully employed to detect continuously varying haematocrit resulting from RBC sedimentation in a driving syringe. The present method can consistently detect variations in blood in terms of the three haemorheological properties.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Republic of Korea
| |
Collapse
|
7
|
Kang YJ. Red Blood Cell Sedimentation Index Using Shear Stress of Blood Flow in Microfluidic Channel. BIOSENSORS 2022; 12:bios12070547. [PMID: 35884350 PMCID: PMC9312500 DOI: 10.3390/bios12070547] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 07/19/2022] [Accepted: 07/19/2022] [Indexed: 11/30/2022]
Abstract
Red blood cell sedimentation has been used as a promising indicator of hematological diseases and disorders. However, to address several issues (i.e., syringe installation direction, blood on-off flow control, image-based quantification, and hemodilution) raised by the previous methods, it is necessary to devise a new method for the effective quantification of red blood cell sedimentation under a constant blood flow. In this study, the shear stress of a blood flow is estimated by analyzing an interface in a co-flowing channel to quantify the red blood cell sedimentation in blood syringes filled with blood (hematocrit = 50%). A red blood cell sedimentation index is newly suggested by analyzing the temporal variations in the shear stress. According to the experimental investigation, the sedimentation index tends to decrease at a higher flow rate. A higher level of hematocrit has a negative influence on the sedimentation index. As a performance demonstration of the present method, the red blood cell sedimentation processes of various test bloods were quantitatively compared in terms of the shear stress, image intensity, and sedimentation velocity. It was found that the proposed index provided a more than 10-fold increase in sensitivity over the previous method (i.e., image intensity). Additionally, it provided more consistent results than another conventional sedimentation method (sedimentation velocity). In conclusion, the present index can be effectively adopted to monitor the red blood cell sedimentation in a 10-min blood delivery.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Korea
| |
Collapse
|
8
|
A rapid and accurate method for estimating the erythrocyte sedimentation rate using a hematocrit-corrected optical aggregation index. PLoS One 2022; 17:e0270977. [PMID: 35819942 PMCID: PMC9275726 DOI: 10.1371/journal.pone.0270977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2021] [Accepted: 06/21/2022] [Indexed: 11/28/2022] Open
Abstract
Although both the erythrocyte sedimentation rate (ESR) and optically measured erythrocyte aggregation parameters are affected by the hematocrit, this interaction is not considered by the method used to estimate ESR that considers aggregation parameters. In this study, we investigated the relationship between the ESR obtained by the Westergren method and that obtained with an aggregation parameter, namely, the aggregation index (AI) of multiple hematocrit values and fibrinogen-spiked samples with an analysis time of 5–60 s, and attempted to develop a rapid and accurate ESR estimation method. The AIs obtained from 5- and 10-s optical measurements with a fixed hematocrit were highly correlated with the erythrocyte sedimentation velocity. Furthermore, the rate of the AI increase with an increasing hematocrit was not significantly affected by the fibrinogen concentration at these measurement times. On the basis of these results, we defined the hematocrit-corrected aggregation index (HAI). The exponential function of the HAI obtained from the 5-s measurement agreed well with the sedimentation velocity calculated to eliminate the effect of hindered settling, and the HAI and hematocrit could be used to calculate the time constant of the sedimentation curve with a linear regression equation. The ESR value at 1 h was calculated based on the modified Stokes’ law and the HAI obtained from the 5-s measurement and showed an excellent correlation (R = 0.966) with the ESR value obtained by the Westergren method over a wide range of hematocrit and fibrinogen concentrations.
Collapse
|
9
|
Kang YJ. Contributions of Red Blood Cell Sedimentation in a Driving Syringe to Blood Flow in Capillary Channels. MICROMACHINES 2022; 13:mi13060909. [PMID: 35744523 PMCID: PMC9229591 DOI: 10.3390/mi13060909] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 06/02/2022] [Accepted: 06/06/2022] [Indexed: 12/18/2022]
Abstract
The erythrocyte sedimentation rate (ESR), which has been commonly used to detect physiological and pathological diseases in clinical settings, has been quantified using an interface in a vertical tube. However, previous methods do not provide biophysical information on blood during the ESR test. Therefore, it is necessary to quantify the individual contributions in terms of viscosity and pressure. In this study, to quantify RBC sedimentation, the image intensity (Ib) and interface (β) were obtained by analyzing the blood flow in the microfluidic channels. Based on threshold image intensity, the corresponding interfaces of RBCs (Ib > 0.15) and diluent (Ib < 0.15) were employed to obtain the viscosities (µb, µ0) and junction pressures (Pb, P0). Two coefficients (CH1, CH2) obtained from the empirical formulas (µb = µ0 [1 + CH1], Pb = P0 [1 + CH2]) were calculated to quantify RBC sedimentation. The present method was then adopted to detect differences in RBC sedimentation for various suspended blood samples (healthy RBCs suspended in dextran solutions or plasma). Based on the experimental results, four parameters (µ0, P0, CH1, and CH2) are considered to be effective for quantifying the contributions of the hematocrit and diluent. Two coefficients exhibited more consistent trends than the conventional ESR method. In conclusion, the proposed method can effectively detect RBC sedimentation.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Korea
| |
Collapse
|
10
|
Kang YJ. Sequential quantification of blood and diluent using red cell sedimentation-based separation and pressure-induced work in a microfluidic channel. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:1194-1207. [PMID: 35234222 DOI: 10.1039/d1ay02178h] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The erythrocyte sedimentation method has been widely used to detect inflammatory diseases. However, this conventional method still has several drawbacks, such as a large blood volume (∼1 mL) and difficulty in continuous monitoring. Most importantly, image-based methods cannot quantify RBC-rich blood (blood) and RBC-free blood (diluent) simultaneously. In this study, instead of visualizing interface movement in the blood syringe, a simple method is proposed to quantify blood and diluent in microfluidic channels sequentially. The hematocrit was set to 25% to enhance RBC sedimentation and form two layers (blood and diluent) in the blood syringe. An air cavity (∼300 μL) inside the blood syringe was secured to completely remove dead volumes (∼200 μL) in fluidic paths (syringe needle and tubing). Thus, a small blood volume (Vb = 50 μL) suctioned into the blood syringe is sufficient for supplying blood and diluent in the blood channel sequentially. The relative ratio of blood resident time (RBC-to-diluent separation) was quantified using λb, which was obtained by quantifying the image intensity of blood flow. After the junction pressure (Pj) and blood volume (V) were obtained by analyzing the interface in the coflowing channel, the averaged work (Wp [Pa mm3]) was calculated and adopted to detect blood and diluent, respectively. The proposed method was then applied with various concentrations of dextran solution to detect aggregation-elevated blood. The Wp of blood and diluent exhibited substantial differences with respect to dextran solutions ranging from Cdex = 10 to Cdex = 40 mg mL-1. Moreover, λb did not exhibit substantial differences in blood with Cdex > 10 mg mL-1. The variations in λb were comparable to those of the previous method based on interface movement in the blood syringe. In conclusion, the WP could detect blood as well as diluents more effectively than λb. Furthermore, the proposed method substantially reduced the blood volume from 1 mL to 50 μL.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju, Republic of Korea.
| |
Collapse
|
11
|
Quantum-Inspired Interpertable AI-Empowered Decision Support System for Detection of Early-Stage Rheumatoid Arthritis in Primary Care Using Scarce Dataset. MATHEMATICS 2022. [DOI: 10.3390/math10030496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Rheumatoid arthritis (RA) is a chronic inflammatory and long-term autoimmune disease that can lead to joint and bone erosion. This can lead to patients’ disability if not treated in a timely manner. Early detection of RA in settings such as primary care (as the first contact with patients) can have an important role on the timely treatment of the disease. We aim to develop a web-based Decision Support System (DSS) to provide a proper assistance for primary care providers in early detection of RA patients. Using Sparse Fuzzy Cognitive Maps, as well as quantum-learning algorithm, we developed an online web-based DSS to assist in early detection of RA patients, and subsequently classify the disease severity into six different levels. The development process was completed in collaborating with two specialists in orthopedic as well as rheumatology orthopedic surgery. We used a sample of anonymous patient data for development of our model which was collected from Shohada University Hospital, Tabriz, Iran. We compared the results of our model with other machine learning methods (e.g., linear discriminant analysis, Support Vector Machines, and K-Nearest Neighbors). In addition to outperforming other methods of machine learning in terms of accuracy when all of the clinical features are used (accuracy of 69.23%), our model identified the relation of the different features with each other and gave higher explainability comparing to the other methods. For future works, we suggest applying the proposed model in different contexts and comparing the results, as well as assessing its usefulness in clinical practice.
Collapse
|
12
|
Kang YJ. Blood rheometer based on microflow manipulation of continuous blood flows using push-and-back mechanism. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:4871-4883. [PMID: 34586112 DOI: 10.1039/d1ay00948f] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
To understand the contributions of rheological properties to microcirculation, the simultaneous measurement of multiple rheological properties under continuous blood flows has been emphasized. However, existing methods exhibit limitations in terms of continuous and simultaneous monitoring. In this study, a simple method is suggested for simultaneously measuring four rheological properties (i.e., red blood cell (RBC) aggregation, blood viscosity, blood junction pressure, and RBC sedimentation) under a continuous blood flow. Using the push-and-back mechanism, which comprises a co-flowing channel, a test chamber, and an air compliance unit (ACU), blood is supplied to the test chamber and restored into the co-flowing channel periodically and reversely. First, RBC aggregation is quantified based on the intensity of the blood image in the test chamber. Second, blood viscosity and blood junction pressure are determined by analyzing the interface in the co-flowing channel. Lastly, RBC sedimentation is evaluated by analyzing the intensity of the blood image in the blood chamber. Based on quantitative studies involving several vital factors, the tubing length of ACU is set to L = 30 mm. The reference fluid (glycerin [20%]) is controlled in a periodic on-off manner (period = 240 s, and flow rate = 1 mL h-1). The blood flow rate is maintained at 1 mL h-1. Subsequently, the present method is used to determine the rheological properties of several blood samples with different hematocrits or diluents. Compared with previous studies, the present method yields sufficiently consistent trends with respect to the hematocrit level or concentration of dextran solution. The experimental results imply that the present method enables simultaneous and consistent measurements of four rheological properties of blood under continuous blood flows. This method can be regarded as a promising method for monitoring multiple rheological properties of blood circulating under an in vitro closed fluidic circuit.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju, South Korea.
| |
Collapse
|
13
|
Isiksacan Z, Serhatlioglu M, Elbuken C. In vitro analysis of multiple blood flow determinants using red blood cell dynamics under oscillatory flow. Analyst 2021; 145:5996-6005. [PMID: 32720945 DOI: 10.1039/d0an00604a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The flow behavior of blood is determined mainly by red blood cell (RBC) deformation and aggregation as well as blood viscoelasticity. These intricately interdependent parameters should be monitored by healthcare providers to understand all aspects of circulatory flow dynamics under numerous cases including cardiovascular and infectious diseases. Current medical instruments and microfluidic systems lack the ability to quantify these parameters all at once and in physiologically relevant flow conditions. This work presents a handheld platform and a measurement method for quantitative analysis of multiple of these parameters from 50 μl undiluted blood inside a miniaturized channel. The assay is based on an optical transmission analysis of collective RBC deformation and aggregation under near-infrared illumination during a 1 s damped oscillatory flow and at stasis, respectively. Measurements with blood of different hemo-rheological properties demonstrate that the presented approach holds a potential for initiating simultaneous and routine on-chip blood flow analysis even in resource-poor settings.
Collapse
Affiliation(s)
- Ziya Isiksacan
- UNAM - National Nanotechnology Research Center and Institute of Materials Science and Nanotechnology, Bilkent University, 06800, Ankara, Turkey.
| | | | | |
Collapse
|
14
|
Sabuncu AC, Muldur S, Cetin B, Usta OB, Aubry N. β-Dispersion of blood during sedimentation. Sci Rep 2021; 11:2642. [PMID: 33514847 PMCID: PMC7846779 DOI: 10.1038/s41598-021-82171-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Accepted: 01/08/2021] [Indexed: 01/30/2023] Open
Abstract
Aggregation of human red blood cells (RBC) is central to various pathological conditions from bacterial infections to cancer. When left at low shear conditions or at hemostasis, RBCs form aggregates, which resemble stacks of coins, known as 'rouleaux'. We experimentally examined the interfacial dielectric dispersion of aggregating RBCs. Hetastarch, an RBC aggregation agent, is used to mimic conditions leading to aggregation. Hetastrach concentration is incrementally increased in blood from healthy donors to measure the sensitivity of the technique. Time lapse electrical impedance measurements were conducted as red blood cells form rouleaux and sediment in a PDMS chamber. Theoretical modeling was used for obtaining complex permittivity of an effective single red blood cell aggregate at various concentrations of hetastarch. Time response of red blood cells' impedance was also studied to parametrize the time evolution of impedance data. Single aggregate permittivity at the onset of aggregation, evolution of interfacial dispersion parameters, and sedimentation kinetics allowed us to distinguish differential aggregation in blood.
Collapse
Affiliation(s)
- Ahmet C. Sabuncu
- grid.268323.e0000 0001 1957 0327Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, MA 01609 USA
| | - Sinan Muldur
- grid.32224.350000 0004 0386 9924Center for Engineering in Medicine, Massachusetts General Hospital, Harvard Medical School and Shriners Hospitals for Children, Boston, MA 02114 USA
| | - Barbaros Cetin
- grid.18376.3b0000 0001 0723 2427Microfluidics & Lab-On-a-Chip Research Group, Department of Mechanical Engineering, I.D. Bilkent University, Ankara, Turkey
| | - O. Berk Usta
- grid.32224.350000 0004 0386 9924Center for Engineering in Medicine, Massachusetts General Hospital, Harvard Medical School and Shriners Hospitals for Children, Boston, MA 02114 USA
| | - Nadine Aubry
- grid.429997.80000 0004 1936 7531School of Engineering, Tufts University, Medford, MA 02155 USA
| |
Collapse
|
15
|
Kumar S, Ram R, Sarkar A, DasGupta S, Chakraborty S. Rapid determination of erythrocyte sedimentation rate (ESR) by an electrically driven blood droplet biosensor. BIOMICROFLUIDICS 2020; 14:064108. [PMID: 33312329 PMCID: PMC7710385 DOI: 10.1063/5.0026332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2020] [Accepted: 11/13/2020] [Indexed: 05/10/2023]
Abstract
In healthcare practice, the sedimentation rate of red blood cells (erythrocytes) is a widely used clinical parameter for screening of several ailments such as stroke, infectious diseases, and malignancy. In a traditional pathological setting, the total time taken for evaluating this parameter varies typically from 1 to 2 h. Furthermore, the volume of human blood to be drawn for each test, following a gold standard laboratory technique (alternatively known as the Westergren method), varies from 4 to 5 ml. Circumventing the above constraints, here we propose a rapid (∼1 min) and highly energy efficient method for the simultaneous determination of hematocrit and erythrocyte sedimentation rate (ESR) on a microfluidic chip, deploying electrically driven spreading of a tiny drop of blood sample (∼8 μl). Our unique approach estimates these parameters by correlating the same with the time taken by the droplet to spread over a given radius, reproducing the results from more elaborate laboratory settings to a satisfactory extent. Our novel methodology is equally applicable for determining higher ranges of ESR such as high concentration of bilirubin and samples corresponding to patients with anemia and patients with some severe inflammation. Furthermore, the minimal fabrication steps involved in the process, along with the rapidity and inexpensiveness of the test, render the suitability of the strategy in extreme point-of-care settings.
Collapse
Affiliation(s)
- Sumit Kumar
- Advanced Technology Development Centre, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal 721302, India
| | - Rishi Ram
- Department of Mechanical Engineering, Indian Institute of Technology (BHU), Varanasi, Uttar Pradesh 221005, India
| | | | | | - Suman Chakraborty
- Author to whom correspondence should be addressed:. Telephone: +913222282990. Fax: +913222282278
| |
Collapse
|
16
|
Namgung B, Lee T, Tan JKS, Poh DKH, Park S, Chng KZ, Agrawal R, Park SY, Leo HL, Kim S. Vibration motor-integrated low-cost, miniaturized system for rapid quantification of red blood cell aggregation. LAB ON A CHIP 2020; 20:3930-3937. [PMID: 32966494 DOI: 10.1039/d0lc00619j] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Human red blood cells (RBCs) aggregate under low shear conditions, which significantly modulates flow resistance and tissue perfusion. A higher aggregation tendency in blood thus serves as an important clinical indicator for the screening of cardiovascular disorders. Conventional ways of measuring RBC aggregation still require large sample volumes, cumbersome manual procedures, and expensive benchtop systems. These inconvenient and high-cost measurement methods hamper their clinical applicability. Here, we propose a low-cost, miniaturized system to overcome the limitations of these methods. Our system utilizes a coin vibration motor (CVM) to generate a localized vortex for disaggregating RBCs in a disposable fluidic chip. The design of the chip was optimized with fluid dynamics simulations to ensure sufficient shear flow in the localized vortex for RBC disaggregation. The time-dependent increase in light transmittance from an LED light source through the plasma gap while the RBCs re-aggregate is captured with a CMOS camera under stasis conditions to quantify the level of RBC aggregation. Our CVM-based aggregometer was validated against a commercial benchtop system for human blood samples under physiological and pathological conditions, and showed an excellent performance with a high intraclass correlation coefficient of 0.995. In addition, we were able to achieve a rapid measurement (<4 min) with the CVM-based aggregometer, requiring only a 6 μl blood sample. These illustrate the potential of our CVM-based aggregometer for low-cost point-of-care diagnostics without compromising the measurement sensitivity.
Collapse
Affiliation(s)
- Bumseok Namgung
- Department of Biomedical Engineering, National University of Singapore, 9 Engineering Drive 1, 117575, Singapore.
| | - Taewoo Lee
- Department of Biomedical Engineering, National University of Singapore, 9 Engineering Drive 1, 117575, Singapore.
| | - Justin Kok Soon Tan
- Department of Biomedical Engineering, National University of Singapore, 9 Engineering Drive 1, 117575, Singapore. and Institute for Health Innovation and Technology, National University of Singapore, 117599, Singapore
| | - Daren Kiat How Poh
- Department of Biomedical Engineering, National University of Singapore, 9 Engineering Drive 1, 117575, Singapore.
| | - Soyeon Park
- Department of Biomedical Engineering, National University of Singapore, 9 Engineering Drive 1, 117575, Singapore. and Institute for Health Innovation and Technology, National University of Singapore, 117599, Singapore
| | - Kevin Ziyang Chng
- Department of Biomedical Engineering, National University of Singapore, 9 Engineering Drive 1, 117575, Singapore. and Institute for Health Innovation and Technology, National University of Singapore, 117599, Singapore
| | - Rupesh Agrawal
- Department of Ophthalmology, National Healthcare Group Eye Institute, Tan Tock Seng Hospital, 308433, Singapore
| | - Sung-Yong Park
- Department of Mechanical Engineering, San Diego State University, San Diego, CA 92182, USA
| | - Hwa Liang Leo
- Department of Biomedical Engineering, National University of Singapore, 9 Engineering Drive 1, 117575, Singapore.
| | - Sangho Kim
- Department of Biomedical Engineering, National University of Singapore, 9 Engineering Drive 1, 117575, Singapore. and Institute for Health Innovation and Technology, National University of Singapore, 117599, Singapore and The N.1 Institute for Health, National University of Singapore, 117456, Singapore
| |
Collapse
|
17
|
Update on the Pathomechanism, Diagnosis, and Treatment Options for Rheumatoid Arthritis. Cells 2020; 9:cells9040880. [PMID: 32260219 PMCID: PMC7226834 DOI: 10.3390/cells9040880] [Citation(s) in RCA: 365] [Impact Index Per Article: 91.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Revised: 03/28/2020] [Accepted: 03/30/2020] [Indexed: 12/18/2022] Open
Abstract
Rheumatoid arthritis (RA) is an autoimmune disease that involves multiple joints bilaterally. It is characterized by an inflammation of the tendon (tenosynovitis) resulting in both cartilage destruction and bone erosion. While until the 1990s RA frequently resulted in disability, inability to work, and increased mortality, newer treatment options have made RA a manageable disease. Here, great progress has been made in the development of disease-modifying anti-rheumatic drugs (DMARDs) which target inflammation and thereby prevent further joint damage. The available DMARDs are subdivided into (1) conventional synthetic DMARDs (methotrexate, hydrochloroquine, and sulfadiazine), (2) targeted synthetic DMARDs (pan-JAK- and JAK1/2-inhibitors), and (3) biologic DMARDs (tumor necrosis factor (TNF)-α inhibitors, TNF-receptor (R) inhibitors, IL-6 inhibitors, IL-6R inhibitors, B cell depleting antibodies, and inhibitors of co-stimulatory molecules). While DMARDs have repeatedly demonstrated the potential to greatly improve disease symptoms and prevent disease progression in RA patients, they are associated with considerable side-effects and high financial costs. This review summarizes our current understanding of the underlying pathomechanism, diagnosis of RA, as well as the mode of action, clinical benefits, and side-effects of the currently available DMARDs.
Collapse
|
18
|
Kang YJ. Simultaneous measurement method of erythrocyte sedimentation rate and erythrocyte deformability in resource-limited settings. Physiol Meas 2020; 41:025009. [PMID: 32000147 DOI: 10.1088/1361-6579/ab71f3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
OBJECTIVE The individual effects of plasma and red blood cells (RBCs) on the biophysical properties of blood can be monitored by measuring the erythrocyte sedimentation rate (ESR) and RBC deformability simultaneously. However, the previous methods require bulky and expensive facilities (i.e. microscope, high-speed camera, and syringe pump) to deliver blood or capture blood flows. APPROACH To resolve these issues, a simple method for sequential measurement of the ESR and RBC deformability is demonstrated by quantifying the cell-free volume (V CF ), cell-rich volume (V CR ), and blood volume (V B ) inside an air-compressed syringe (ACS). A microfluidic device consists of multiple micropillar channels, an inlet, and outlet. After the ACS is filled with air (V air = 0.4 ml) and a blood sample (V B = 0.6 ml, hematocrit = 30%) sequentially, the ACS is fitted into the inlet. The cavity inside the ACS is compressed to V comp = 0.4 ml after closing the outlet with a stopper. A smartphone camera is employed to capture variations in the V CF , V CR , and V B inside the ACS. The ESR index suggested in this study (ESR PM ) is obtained by dividing the V CF (t = t 1) with an elapse of t 1. By removing the stopper, ΔV B (ΔV B = V B [t = t 1] - V B ) is obtained and fitted as a two-term exponential model ([Formula: see text]. As a performance demonstration, the proposed method is employed to detect an ESR-enhanced blood sample, homogeneous hardened blood sample, and heterogeneous blood sample. MAIN RESULTS From the experimental results, it is found that the proposed method has the ability to detect various bloods by quantifying the ESR PM and two coefficients (a, b) simultaneously. SIGNIFICANCE In conclusion, the present method can be effectively used to measure the ESR and RBC deformability in resource-limited settings.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Republic of Korea
| |
Collapse
|
19
|
Kang YJ. Microfluidic-Based Biosensor for Blood Viscosity and Erythrocyte Sedimentation Rate Using Disposable Fluid Delivery System. MICROMACHINES 2020; 11:mi11020215. [PMID: 32093288 PMCID: PMC7074636 DOI: 10.3390/mi11020215] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/09/2020] [Revised: 02/11/2020] [Accepted: 02/18/2020] [Indexed: 11/16/2022]
Abstract
To quantify the variation of red blood cells (RBCs) or plasma proteins in blood samples effectively, it is necessary to measure blood viscosity and erythrocyte sedimentation rate (ESR) simultaneously. Conventional microfluidic measurement methods require two syringe pumps to control flow rates of both fluids. In this study, instead of two syringe pumps, two air-compressed syringes (ACSs) are newly adopted for delivering blood samples and reference fluid into a T-shaped microfluidic channel. Under fluid delivery with two ACS, the flow rate of each fluid is not specified over time. To obtain velocity fields of reference fluid consistently, RBCs suspended in 40% glycerin solution (hematocrit = 7%) as the reference fluid is newly selected for avoiding RBCs sedimentation in ACS. A calibration curve is obtained by evaluating the relationship between averaged velocity obtained with micro-particle image velocimetry (μPIV) and flow rate of a syringe pump with respect to blood samples and reference fluid. By installing the ACSs horizontally, ESR is obtained by monitoring the image intensity of the blood sample. The averaged velocities of the blood sample and reference fluid (<UB>, <UR>) and the interfacial location in both fluids (αB) are obtained with μPIV and digital image processing, respectively. Blood viscosity is then measured by using a parallel co-flowing method with a correction factor. The ESR is quantified as two indices (tESR, IESR) from image intensity of blood sample (<IB>) over time. As a demonstration, the proposed method is employed to quantify contributions of hematocrit (Hct = 30%, 40%, and 50%), base solution (1× phosphate-buffered saline [PBS], plasma, and dextran solution), and hardened RBCs to blood viscosity and ESR, respectively. Experimental Results of the present method were comparable with those of the previous method. In conclusion, the proposed method has the ability to measure blood viscosity and ESR consistently, under fluid delivery of two ACSs.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Korea
| |
Collapse
|
20
|
Agarwal R, Sarkar A, Paul S, Chakraborty S. A portable rotating disc as blood rheometer. BIOMICROFLUIDICS 2019; 13:064120. [PMID: 31803338 PMCID: PMC6887659 DOI: 10.1063/1.5128937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Accepted: 11/19/2019] [Indexed: 06/10/2023]
Abstract
Abnormalities in biophysical properties of blood are often strong indicators of life threatening infections. However, there is no existing device that integrates the sensing of blood hematocrit (or equivalently, packed cell volume), viscosity, and erythrocyte sedimentation rate (ESR) in a unified paradigm for point-of-care diagnostics. In an effort to develop a rapid, integrated, accurate, portable, and inexpensive sensing platform to diagnose the corresponding pathophysical parameters, we develop a simple and portable spinning disk capable of yielding these results in a few minutes instead of the traditional duration of hours. The device requires only 40 μl of unprocessed freshly drawn blood treated with an anticoagulant ethylenediaminetetraacetic acid, instead of the traditional requirement of 2 ml of blood for just the ESR measurement and still more for hematocrit determination. In contrast to the sophisticated instrumentation required to determine these parameters by the previously proposed microfluidic devices, our device requires minimal infrastructure. The measurement of hematocrit is accomplished by means of a simple 15 cm ruler. Additionally, a simple measurement of the blood flow rate enables the determination of the ESR value. The rapidity, ease, accuracy, portability, frugality, and possible automation of the overall measurement process of some of the most important parameters of blood under infection pinpoint its utility in extreme point-of-care settings.
Collapse
Affiliation(s)
- Rahul Agarwal
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | | | - Subhechchha Paul
- Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology, Shibpur 711103, India
| | - Suman Chakraborty
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| |
Collapse
|
21
|
Microfluidic-Based Biosensor for Sequential Measurement of Blood Pressure and RBC Aggregation Over Continuously Varying Blood Flows. MICROMACHINES 2019; 10:mi10090577. [PMID: 31480325 PMCID: PMC6780160 DOI: 10.3390/mi10090577] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Revised: 08/23/2019] [Accepted: 08/28/2019] [Indexed: 12/18/2022]
Abstract
Aggregation of red blood cells (RBCs) varies substantially depending on changes of several factors such as hematocrit, membrane deformability, and plasma proteins. Among these factors, hematocrit has a strong influence on the aggregation of RBCs. Thus, while measuring RBCs aggregation, it is necessary to monitor hematocrit or, additionally, the effect of hematocrit (i.e., blood viscosity or pressure). In this study, the sequential measurement method of pressure and RBC aggregation is proposed by quantifying blood flow (i.e., velocity and image intensity) through a microfluidic device, in which an air-compressed syringe (ACS) is used to control the sample injection. The microfluidic device used is composed of two channels (pressure channel (PC), and blood channel (BC)), an inlet, and an outlet. A single ACS (i.e., air suction = 0.4 mL, blood suction = 0.4 mL, and air compression = 0.3 mL) is employed to supply blood into the microfluidic channel. At an initial time (t < 10 s), the pressure index (PI) is evaluated by analyzing the intensity of microscopy images of blood samples collected inside PC. During blood delivery with ACS, shear rates of blood flows vary continuously over time. After a certain amount of time has elapsed (t > 30 s), two RBC aggregation indices (i.e., SEAI: without information on shear rate, and erythrocyte aggregation index (EAI): with information on shear rate) are quantified by analyzing the image intensity and velocity field of blood flow in BC. According to experimental results, PI depends significantly on the characteristics of the blood samples (i.e., hematocrit or base solutions) and can be used effectively as an alternative to blood viscosity. In addition, SEAI and EAI also depend significantly on the degree of RBC aggregation. In conclusion, on the basis of three indices (two RBC aggregation indices and pressure index), the proposed method is capable of measuring RBCs aggregation consistently using a microfluidic device.
Collapse
|
22
|
Kang YJ, Lee SJ. In vitro and ex vivo measurement of the biophysical properties of blood using microfluidic platforms and animal models. Analyst 2019; 143:2723-2749. [PMID: 29740642 DOI: 10.1039/c8an00231b] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Haemorheologically impaired microcirculation, such as blood clotting or abnormal blood flow, causes interrupted blood flows in vascular networks. The biophysical properties of blood, including blood viscosity, blood viscoelasticity, haematocrit, red blood bell (RBC) aggregation, erythrocyte sedimentation rate and RBC deformability, have been used to monitor haematological diseases. In this review, we summarise several techniques for measuring haemorheological properties, such as blood viscosity, RBC deformability and RBC aggregation, using in vitro microfluidic platforms. Several methodologies for the measurement of haemorheological properties with the assistance of an extracorporeal rat bypass loop are also presented. We briefly discuss several emerging technologies for continuous, long-term, multiple measurements of haemorheological properties under in vitro or ex vivo conditions.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, Gwangju, Republic of Korea
| | | |
Collapse
|
23
|
Kang YJ. Simultaneous measurement of blood pressure and RBC aggregation by monitoring on–off blood flows supplied from a disposable air-compressed pump. Analyst 2019; 144:3556-3566. [DOI: 10.1039/c9an00025a] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
A simple method for simultaneously measuring RBC aggregation and blood pressure is demonstrated by analyzing blood flows supplied from a disposable air-compressed pump.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering
- Chosun University
- Gwangju
- Republic of Korea
| |
Collapse
|
24
|
Kang YJ. A Disposable Blood-on-a-Chip for Simultaneous Measurement of Multiple Biophysical Properties. MICROMACHINES 2018; 9:E475. [PMID: 30424408 PMCID: PMC6215101 DOI: 10.3390/mi9100475] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/25/2018] [Revised: 09/15/2018] [Accepted: 09/17/2018] [Indexed: 12/11/2022]
Abstract
Biophysical properties are widely used to detect pathophysiological processes of vascular diseases or clinical states. For early detection of cardiovascular diseases, it is necessary to simultaneously measure multiple biophysical properties in a microfluidic environment. However, a microfluidic-based technique for measuring multiple biophysical properties has not been demonstrated. In this study, a simple measurement method was suggested to quantify three biophysical properties of blood, including red blood cell (RBC) deformability, RBC aggregation, and hematocrit. To demonstrate the suggested method, a microfluidic device was constructed, being composed of a big-sized channel (BC), a parallel micropillar (MP), a main channel, a branch channel, inlet, and outlets. By operating a single syringe pump, blood was supplied into the inlet of the microfluidic device, at a periodic on-off profile (i.e., period = 240 s). The RBC deformability index (DI) was obtained by analyzing the averaged blood velocity in the branch channel. Additionally, the RBC aggregation index (AIN) and the hematocrit index (HiBC) were measured by analyzing the image intensity of blood flows in the MP and the BC, respectively. The corresponding contributions of three influencing factors, including the turn-on time (Ton), the amplitude of blood flow rate (Q₀), and the hematocrit (Hct) on the biophysical indices (DI, AIN, and HiBC) were evaluated quantitatively. As the three biophysical indices varied significantly with respect to the three factors, the following conditions (i.e., Ton = 210 s, Q₀ = 1 mL/h, and Hct = 50%) were maintained for consistent measurement of biophysical properties. The proposed method was employed to detect variations of biophysical properties depending on the concentrations of autologous plasma, homogeneous hardened RBCs, and heterogeneous hardened RBCs. Based on the observations, the proposed method exhibited significant differences in biophysical properties depending on base solutions, homogeneous hardened RBCs (i.e., all RBCs fixed with the same concentration of glutaraldehyde solution), and heterogeneous hardened RBCs (i.e., partially mixed with normal RBCs and homogeneous hardened RBCs). Additionally, the suggested indices (i.e., DI, AIN, and HiBC) were effectively employed to quantify three biophysical properties, including RBC deformability, RBC aggregation, and hematocrit.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Korea.
| |
Collapse
|
25
|
Kang YJ. Microfluidic-Based Technique for Measuring RBC Aggregation and Blood Viscosity in a Continuous and Simultaneous Fashion. MICROMACHINES 2018; 9:E467. [PMID: 30424400 PMCID: PMC6187833 DOI: 10.3390/mi9090467] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/24/2018] [Revised: 09/06/2018] [Accepted: 09/11/2018] [Indexed: 01/04/2023]
Abstract
Hemorheological properties such as viscosity, deformability, and aggregation have been employed to monitor or screen patients with cardiovascular diseases. To effectively evaluate blood circulating within an in vitro closed circuit, it is important to quantify its hemorheological properties consistently and accurately. A simple method for measuring red blood cell (RBC) aggregation and blood viscosity is proposed for analyzing blood flow in a microfluidic device, especially in a continuous and simultaneous fashion. To measure RBC aggregation, blood flows through three channels: the left wide channel, the narrow channel and the right wide channel sequentially. After quantifying the image intensity of RBCs aggregated in the left channel () and the RBCs disaggregated in the right channel (), the RBC aggregation index (AIPM) is obtained by dividing by . Simultaneously, based on a modified parallel flow method, blood viscosity is obtained by detecting the interface between two fluids in the right wide channel. RBC aggregation and blood viscosity were first evaluated under constant and pulsatile blood flows. AIPM varies significantly with respect to blood flow rate (for both its amplitude and period) and the concentration of the dextran solution used. According to our quantitative comparison between the proposed aggregation index (AIPM) and the conventional aggregation index (AICM), it is found that AIPM provides consistent results. Finally, the suggested method is employed to obtain the RBC aggregation and blood viscosity of blood circulating within an in vitro fluidic circuit. The experimental results lead to the conclusion that the proposed method can be successfully used to measure RBC aggregation and blood viscosity, especially in a continuous and simultaneous fashion.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Korea.
| |
Collapse
|
26
|
Schapkaitz E, RabuRabu S, Engelbrecht M. Differences in erythrocyte sedimentation rates using a modified Westergren method and an alternate method. J Clin Lab Anal 2018; 33:e22661. [PMID: 30152149 DOI: 10.1002/jcla.22661] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Revised: 07/13/2018] [Accepted: 08/03/2018] [Indexed: 01/20/2023] Open
Abstract
INTRODUCTION Worldwide laboratories have adopted the use of modified or alternate methods for measurement of the erythrocyte sedimentation rate (ESR). The iSED from Alcor Scientific is a novel, alternate ESR method based on photometric aggregometry which offers improved operator safety and reduced analysis time. This study evaluated the diagnostic utility of the iSED in a South African patient population with a range of inflammatory disorders. METHODS We compared the iSED with the predicate modified Westergren method (StaRRsed, Mechatronics, Zwaag, the Netherlands) measured at 60 minutes. Analysis was performed on K2 EDTA samples at three ESR measurement ranges (<20, 20-80 and >80 mm/h) in 120 pediatric and adult inpatients and outpatients over a 2-week period. Precision, stability, and carryover were performed in accordance with the revised International Council for Standardisation in Haematology guidelines. RESULTS The iSED demonstrated acceptable imprecision with minimal carryover (2.86%). The correlation coefficients at the 3 ESR measurement ranges were r = 0.58, r = 0.71, and r = 0.56, respectively. The y-intercepts were -10.74 (CI -29.17 to 7.69), -5.95 (CI -18.60 to 6.69) and 246.05 (CI 591.42-99.31). This indicated a difference of a constant nature with an overall mean difference of 7.99 mm/h (CI 5.87-10.13) (P < 0.001). iSED ESR measurements were stable up to 24 hours when stored at room temperature or at 4-8°C. CONCLUSION This study demonstrated differences in ESR results, predominantly at extremes of the analytical range, using an alternate method. Careful consideration and performance monitoring of these novel methods are advised.
Collapse
Affiliation(s)
- Elise Schapkaitz
- Department of Molecular Medicine and Hematology, Faculty of Health Sciences, University of Witwatersrand Medical School, Johannesburg, South Africa
| | - Shilla RabuRabu
- Department of Molecular Medicine and Hematology, National Health Laboratory Service, Johannesburg, South Africa
| | - Marcel Engelbrecht
- Department of Molecular Medicine and Hematology, Faculty of Health Sciences, University of Witwatersrand Medical School, Johannesburg, South Africa
| |
Collapse
|
27
|
Kang YJ, Kim BJ. Multiple and Periodic Measurement of RBC Aggregation and ESR in Parallel Microfluidic Channels under On-Off Blood Flow Control. MICROMACHINES 2018; 9:mi9070318. [PMID: 30424251 PMCID: PMC6082273 DOI: 10.3390/mi9070318] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2018] [Revised: 06/13/2018] [Accepted: 06/21/2018] [Indexed: 01/25/2023]
Abstract
Red blood cell (RBC) aggregation causes to alter hemodynamic behaviors at low flow-rate regions of post-capillary venules. Additionally, it is significantly elevated in inflammatory or pathophysiological conditions. In this study, multiple and periodic measurements of RBC aggregation and erythrocyte sedimentation rate (ESR) are suggested by sucking blood from a pipette tip into parallel microfluidic channels, and quantifying image intensity, especially through single experiment. Here, a microfluidic device was prepared from a master mold using the xurography technique rather than micro-electro-mechanical-system fabrication techniques. In order to consider variations of RBC aggregation in microfluidic channels due to continuous ESR in the conical pipette tip, two indices (aggregation index (AI) and erythrocyte-sedimentation-rate aggregation index (EAI)) are evaluated by using temporal variations of microscopic, image-based intensity. The proposed method is employed to evaluate the effect of hematocrit and dextran solution on RBC aggregation under continuous ESR in the conical pipette tip. As a result, EAI displays a significantly linear relationship with modified conventional ESR measurement obtained by quantifying time constants. In addition, EAI varies linearly within a specific concentration of dextran solution. In conclusion, the proposed method is able to measure RBC aggregation under continuous ESR in the conical pipette tip. Furthermore, the method provides multiple data of RBC aggregation and ESR through a single experiment. A future study will involve employing the proposed method to evaluate biophysical properties of blood samples collected from cardiovascular diseases.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju 61452, Korea.
| | - Byung Jun Kim
- Department of Biomedical Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Korea.
| |
Collapse
|
28
|
Kang YJ. Periodic and simultaneous quantification of blood viscosity and red blood cell aggregation using a microfluidic platform under in-vitro closed-loop circulation. BIOMICROFLUIDICS 2018; 12:024116. [PMID: 29682144 PMCID: PMC5891346 DOI: 10.1063/1.5017052] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2017] [Accepted: 03/29/2018] [Indexed: 05/13/2023]
Abstract
To evaluate variations of blood circulating in closed loops, hemorheological properties including blood viscosity and red blood cells (RBCs) are quantitatively measured with independent in-vitro instruments after collecting blood from a closed loop. But, most previous methods require periodic blood collections which induce several problems such as geometric differences between the fluidic channel and the in-vitro method, hemodilution, storage time, and unspecific blood flow rates. To resolve these issues, in this study, blood viscosity and RBC aggregation of blood circulating within a closed loop are measured with a microfluidic platform periodically and simultaneously. To demonstrate the proposed method, in-vitro closed-loop circulation is established by connecting several components (peristaltic pump, air compliance unit, fluid divider, and reservoir) in series. In addition, to measure blood viscosity and RBC aggregation, a microfluidic platform composed of a microfluidic device, pinch valve, and syringe pump is created. During each period, blood viscosity and RBC aggregation are measured by monitoring blood flow at constant blood flow, and image intensity at stationary blood flow. The proposed method is first employed to evaluate the effect of hematocrits and dextran concentrations on the RBC aggregation and blood viscosity by using a syringe pump (i.e., specific blood flow-rate). The method is then applied to detect the blood viscosity and RBC aggregation under in-vitro closed-loop circulation (i.e., unspecific blood flow-rate). From these experimental demonstrations, it is found that the suggested method can be effectively used to monitor the RBC aggregation and blood viscosity under in-vitro closed-loop circulation. Since this method does not require periodic collection from closed-loop circulation or an additional procedure for estimating blood flow-rate with a syringe pump, it will be effectively used to monitor variations of blood circulating in extracorporeal bypass loops.
Collapse
Affiliation(s)
- Yang Jun Kang
- Department of Mechanical Engineering, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju, South Korea
| |
Collapse
|
29
|
Microfluidic-Based Measurement Method of Red Blood Cell Aggregation under Hematocrit Variations. SENSORS 2017; 17:s17092037. [PMID: 28878199 PMCID: PMC5620946 DOI: 10.3390/s17092037] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/08/2017] [Revised: 09/02/2017] [Accepted: 09/04/2017] [Indexed: 01/29/2023]
Abstract
Red blood cell (RBC) aggregation and erythrocyte sedimentation rate (ESR) are considered to be promising biomarkers for effectively monitoring blood rheology at extremely low shear rates. In this study, a microfluidic-based measurement technique is suggested to evaluate RBC aggregation under hematocrit variations due to the continuous ESR. After the pipette tip is tightly fitted into an inlet port, a disposable suction pump is connected to the outlet port through a polyethylene tube. After dropping blood (approximately 0.2 mL) into the pipette tip, the blood flow can be started and stopped by periodically operating a pinch valve. To evaluate variations in RBC aggregation due to the continuous ESR, an EAI (Erythrocyte-sedimentation-rate Aggregation Index) is newly suggested, which uses temporal variations of image intensity. To demonstrate the proposed method, the dynamic characterization of the disposable suction pump is first quantitatively measured by varying the hematocrit levels and cavity volume of the suction pump. Next, variations in RBC aggregation and ESR are quantified by varying the hematocrit levels. The conventional aggregation index (AI) is maintained constant, unrelated to the hematocrit values. However, the EAI significantly decreased with respect to the hematocrit values. Thus, the EAI is more effective than the AI for monitoring variations in RBC aggregation due to the ESR. Lastly, the proposed method is employed to detect aggregated blood and thermally-induced blood. The EAI gradually increased as the concentration of a dextran solution increased. In addition, the EAI significantly decreased for thermally-induced blood. From this experimental demonstration, the proposed method is able to effectively measure variations in RBC aggregation due to continuous hematocrit variations, especially by quantifying the EAI.
Collapse
|
30
|
Chaturvedi A, Nagaraj SK, Gorthi SS, Seelamantula CS. An Efficient Microscale Technique for Determining the Erythrocyte Sedimentation Rate. SLAS Technol 2017; 22:565-572. [PMID: 28395141 DOI: 10.1177/2472630317703982] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The erythrocyte sedimentation rate (ESR) is a commonly used test to screen for inflammatory conditions such as infections, autoimmune diseases, and cancers. However, it is a bulk macroscale test that requires a relatively large blood sample and takes a long time to run. Moreover, it provides no information regarding cell sizes or interactions, which can be highly variable. To overcome these drawbacks, we developed a microfluidic microscopy-based protocol to dynamically track settling red blood cells (RBCs) to quantify velocity of cell settling, as a surrogate for the ESR. We imaged individual cells in a vertical microfluidic channel and applied a hybrid cell detection and tracking algorithm to compute settling velocities. We combined eigenvalue background subtraction and centroid detection together with the Kalman filter and Hungarian assignment solver algorithms to increase accuracy and computational speed. Our algorithm is designed to track settling RBCs/aggregates in high cellularity samples rather than single cells in suspension. Detection accuracy was 79.3%, which is comparable to state-of-the-art cell-tracking techniques. Compared with conventional ESR tests, our approach has the advantages of being automated, using microliter volumes of blood samples, and rapid turnaround.
Collapse
Affiliation(s)
- Akhil Chaturvedi
- 1 Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA
| | - Sujith Kumar Nagaraj
- 2 Department of Electronics and Communication Engineering, RV College of Engineering, Bangalore, India
| | - Sai Siva Gorthi
- 3 Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore, India
| | | |
Collapse
|