1
|
Julius LA, Torres Delgado SM, Mishra R, Kent N, Carthy E, Korvink JG, Mager D, Ducrée J, Kinahan DJ. Programmable fluidic networks on centrifugal microfluidic discs. Anal Chim Acta 2024; 1288:342159. [PMID: 38220291 DOI: 10.1016/j.aca.2023.342159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 12/08/2023] [Accepted: 12/16/2023] [Indexed: 01/16/2024]
Abstract
BACKGROUND Biomedical diagnostic and lab automation solutions built on the Lab-on-a-Disc (LoaD) platform has great potential due to their independence from specialised micro-pumps and their ease of integration, through direct pipetting, with manual or automated workflows. However, a challenge for all microfluidic chips is their cost of manufacture when each microfluidic disc must be customized for a specific application. In this paper, we present centrifugal discs with programmable fluidic networks. RESULTS Based on dissolvable film valves, we present two technologies. The first, based on recently introduced pulse-actuated dissolvable film valves, is a centrifugal disc which, depending on how it is loaded, is configured to perform either six sequential reagent releases through one reaction chamber or three sequential reagent releases through two reaction chambers. In the second approach, we use the previously introduced electronic Lab-on-a-Disc (eLoaD) wireless valve array, which can actuate up to 128 centrifugo-pneumatic dissolvable film valves in a pre-defined sequence. In this approach we present a disc which can deliver any one of 8 reagent washes to any one of four reaction chambers. We use identical discs to demonstrate the first four sequential washes through two reaction chambers and then two sequential washes through four reaction chambers. SIGNIFICANCE These programmable fluidic networks have the potential to allow a single disc architecture to be applied to multiple different assay types and so can offer a lower-cost and more integrated alternative to the standard combination of micro-titre plate and liquid handling robot. Indeed, it may even be possible to conduct multiple different assays concurrently. This can have the effect of reducing manufacturing costs and streamlining supply-chains and so results in a more accessible diagnostic platform.
Collapse
Affiliation(s)
- Lourdes An Julius
- Fraunhofer Project Center at Dublin City University (FPC@DCU), Dublin City University, Glasnevin, Dublin 9, Ireland; School of Physical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Sarai M Torres Delgado
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, Eggenstein-Lepolshafen, 76344, Germany
| | - Rohit Mishra
- Fraunhofer Project Center at Dublin City University (FPC@DCU), Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Nigel Kent
- School of Mechanical & Manufacturing Engineering, Dublin City University, Glasnevin, Dublin 9, Ireland; National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin 9, Ireland; Biodesign Europe, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Eadaoin Carthy
- School of Mechanical & Manufacturing Engineering, Dublin City University, Glasnevin, Dublin 9, Ireland; National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin 9, Ireland; Biodesign Europe, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Jan G Korvink
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, Eggenstein-Lepolshafen, 76344, Germany
| | - Dario Mager
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, Eggenstein-Lepolshafen, 76344, Germany
| | - Jens Ducrée
- School of Physical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland; National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin 9, Ireland; Biodesign Europe, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - David J Kinahan
- School of Mechanical & Manufacturing Engineering, Dublin City University, Glasnevin, Dublin 9, Ireland; National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin 9, Ireland; Biodesign Europe, Dublin City University, Glasnevin, Dublin 9, Ireland; I-Form, The SFI Research Centre for Advanced Manufacturing, Dublin City University, Dublin 9, Ireland.
| |
Collapse
|
2
|
Early PL, Kilcawley NA, McArdle NA, Renou M, Kearney SM, Mishra R, Dimov N, Glynn MT, Ducrée J, Kinahan DJ. Digital process control of multi-step assays on centrifugal platforms using high-low-high rotational-pulse triggered valving. PLoS One 2023; 18:e0291165. [PMID: 37682949 PMCID: PMC10490917 DOI: 10.1371/journal.pone.0291165] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Accepted: 08/23/2023] [Indexed: 09/10/2023] Open
Abstract
Due to their capability for comprehensive sample-to-answer automation, the interest in centrifugal microfluidic systems has greatly increased in industry and academia over the last quarter century. The main applications of these "Lab-on-a-Disc" (LoaD) platforms are in decentralised bioanalytical point-of-use / point-of-care testing. Due to the unidirectional and omnipresent nature of the centrifugal force, advanced flow control is key to coordinate multi-step / multi-reagent assay formats on the LoaD. Formerly, flow control was often achieved by capillary burst valves which require gradual increments of the spin speed of the system-innate spindle motor. Recent advanced introduced a flow control scheme called 'rotational pulse actuated valves'. In these valves the sequence of valve actuation is determined by the architecture of the disc while actuation is triggered by freely programmable upward spike (i.e. Low-High-Low (LHL)) in the rotational frequency. This paradigm shift from conventional 'analogue' burst valves to 'digital' pulsing significantly increases the number of sequential while also improving the overall robustness of flow control. In this work, we expand on these LHL valves by introducing High-Low-High (HLH) pulse-actuated (PA) valving which are actuated by 'downward' spike in the disc spin-rate. These HLH valves are particularly useful for high spin-rate operations such as centrifugation of blood. We introduce two different HLH architectures and then combine the most promising with LHL valves to implement the time-dependent liquid handling protocol underlying a common liver function test panel.
Collapse
Affiliation(s)
- Philip L. Early
- School of Physical Sciences, Dublin City University, Glasnevin, Dublin, Ireland
- National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin, Ireland
| | - Niamh A. Kilcawley
- School of Physical Sciences, Dublin City University, Glasnevin, Dublin, Ireland
- National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin, Ireland
| | - Niamh A. McArdle
- School of Physical Sciences, Dublin City University, Glasnevin, Dublin, Ireland
- National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin, Ireland
| | - Marine Renou
- School of Physical Sciences, Dublin City University, Glasnevin, Dublin, Ireland
- National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin, Ireland
- Telecom Physique Strasbourg, Université de Strasbourg, Strasbourg, France
| | - Sinéad M. Kearney
- School of Physical Sciences, Dublin City University, Glasnevin, Dublin, Ireland
- National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin, Ireland
| | - Rohit Mishra
- School of Physical Sciences, Dublin City University, Glasnevin, Dublin, Ireland
- National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin, Ireland
| | - Nikolay Dimov
- School of Physical Sciences, Dublin City University, Glasnevin, Dublin, Ireland
- National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin, Ireland
| | - Macdara T. Glynn
- School of Physical Sciences, Dublin City University, Glasnevin, Dublin, Ireland
- National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin, Ireland
| | - Jens Ducrée
- School of Physical Sciences, Dublin City University, Glasnevin, Dublin, Ireland
- National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin, Ireland
| | - David J. Kinahan
- School of Physical Sciences, Dublin City University, Glasnevin, Dublin, Ireland
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland
| |
Collapse
|
3
|
Xiao Y, Li S, Pang Z, Wan C, Li L, Yuan H, Hong X, Du W, Feng X, Li Y, Chen P, Liu BF. Multi-reagents dispensing centrifugal microfluidics for point-of-care testing. Biosens Bioelectron 2022; 206:114130. [PMID: 35245866 DOI: 10.1016/j.bios.2022.114130] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Revised: 02/21/2022] [Accepted: 02/22/2022] [Indexed: 12/24/2022]
Abstract
Point-of-care testing (POCT) has shown great advantages for public health monitoring in resource-limited settings. However, developing of POCT tools with automated and accurate quantitative dispensing of multiple reagents and samples is challenging. Here, we demonstrate a novel multi-reagents dispensing centrifugal microfluidics (MDCM) that allows rapid and automated dispensing of multiple reagents and samples with high throughput and accuracy. The MDCM was designed with multiple aliquoting units with the hydrophobic valve at different radial positions. All reagents and samples were loaded simultaneously, dispensed in parallel by centrifugation at low speed, and then introduced into the reaction chamber sequentially by centrifugation at high speed. Two MDCM chips are demonstrated, including a uniform concentration generator and a gradient concentration generator. The concentration coefficient of variation (CV) among the independent reaction chambers was lower than 0.56%, and the theoretical quantitative concentration gradient was strongly correlated with the actual concentration gradient (R2 = 0.9938). We have successfully applied the MDCM to loop-mediated isothermal amplification (LAMP)-based nucleic acid detection for multiple infectious pathogens and antimicrobial susceptibility testing (AST) for kanamycin sulfate against E. coli. To further extend the applications, the MDCM has also been applied to bicinchoninic acid (BCA) protein assays with online calibration, reducing the detection time from 2 h to 10 min with a twenty-fold reduction in reagent consumption. These results indicated that the MDCM is a high potential platform for POCT.
Collapse
Affiliation(s)
- Yujin Xiao
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Shunji Li
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Zheng Pang
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Chao Wan
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Lina Li
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Huijuan Yuan
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Xianzhe Hong
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Wei Du
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Xiaojun Feng
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Yiwei Li
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Peng Chen
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China.
| | - Bi-Feng Liu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| |
Collapse
|
4
|
Haraguchi Y, Kagawa Y, Kubo H, Shimizu T. Analysis of force vector field during centrifugation for optimizing cell sheet adhesion. Biotechnol Prog 2019; 35:e2857. [PMID: 31148395 DOI: 10.1002/btpr.2857] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2019] [Revised: 05/16/2019] [Accepted: 05/24/2019] [Indexed: 11/08/2022]
Abstract
A three-dimensional tissue was fabricated by layering cell sheets with centrifugation. In this system, an optimal centrifugal force promoted the adhesion between (a) a cell sheet and a culture dish, and (b) layered cell sheets, resulting in a significant decrease in the fabrication time of the tissue. However, negative effects like sliding/significant deformation of cell sheets were observed upon high rotational speed use. These negative effects inhibit the further shortening of the fabrication time. The sliding/deformation suggests that the centrifugal forces were applied on the cell sheets in unwanted directions. Studies on the force vector field applied to the object placed on the plate during centrifugation are not available, and thus, the reason for the occurrence of such negative effects is unclear. Here, we theoretically derived the spatial distribution of acceleration applied on a plate during centrifugation. Using this theory, we found that the negative effects were triggered by the centrifugal force in the direction parallel to the plate surface, which appeared due to an inclination of the plate surface against a horizontal plane. Therefore, by adding weights on the plate edge to maintain the plate surface in a horizontal position, we succeeded in eliminating the negative effects and in increasing the rotational speed, with the minimum risk of sliding/deformation of cell sheets. We succeeded in reducing the time to establish tight adhesion between a mouse myoblast sheet and a culture dish, and layered cell sheets by increasing the centrifugal force from 5 min to 1 min without significant cytotoxicity.
Collapse
Affiliation(s)
- Yuji Haraguchi
- Institute of Advanced Biomedical Engineering and Science, TWIns, Tokyo Women's Medical University, Shinjuku-ku, Tokyo, Japan
| | - Yuki Kagawa
- Ogino Memorial Laboratory, Nihon Kohden Corporation, TWIns, Shinjuku-ku, Tokyo, Japan
| | - Hirotsugu Kubo
- Ogino Memorial Laboratory, Nihon Kohden Corporation, TWIns, Shinjuku-ku, Tokyo, Japan
| | - Tatsuya Shimizu
- Institute of Advanced Biomedical Engineering and Science, TWIns, Tokyo Women's Medical University, Shinjuku-ku, Tokyo, Japan
| |
Collapse
|
5
|
Mi S, Du Z, Xu Y, Sun W. The crossing and integration between microfluidic technology and 3D printing for organ-on-chips. J Mater Chem B 2018; 6:6191-6206. [PMID: 32254609 DOI: 10.1039/c8tb01661e] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Organ-on-chips were designed to simulate the real tissue or organ microenvironment by precise control of the cells, the extracellular matrix and other micro-environmental factors to clarify physiological or pathological mechanisms. The organ chip is mainly based on the poly(dimethylsiloxane) (PDMS) microfluidic devices, whereas the conventional soft lithography requires a cumbersome manufacturing process, and the complex on-chip tissue or organ chip also depends on the complicated loading process of the cells and biomaterials. 3D printing can efficiently design and automatically print micrometre-scale devices, while bio-printing can also precisely manipulate cells and biomaterials to create complex organ or tissue structures. In recent years, the popularization of 3D printing has provided more possibilities for its application to 3D printed organ-on-chips. The combination of 3D printing and microfluidic technology in organ-on-chips provides a more efficient choice for building complex flow channels or chambers, as well as the ability to create biological structures with a 3D cell distribution, heterogeneity and tissue-specific function. The fabrication of complex, heterogeneous 3D printable biomaterials based on microfluidics also provides new assistance for building complex organ-on-chips. Here, we discuss the recent advances and potential applications of 3D printing in combination with microfluidics to organ-on-chips and provide outlooks on the integration of the two technologies in building efficient, automated, modularly integrated, and customizable organ-on-chips.
Collapse
Affiliation(s)
- Shengli Mi
- Biomanufacturing Engineering Laboratory, Advanced Manufacturing Division, Graduate School at Shenzhen, Tsinghua University, Shenzhen, P. R. China.
| | | | | | | |
Collapse
|
6
|
Tang M, Huang X, Chu Q, Ning X, Wang Y, Kong SK, Zhang X, Wang G, Ho HP. A linear concentration gradient generator based on multi-layered centrifugal microfluidics and its application in antimicrobial susceptibility testing. LAB ON A CHIP 2018; 18:1452-1460. [PMID: 29664087 DOI: 10.1039/c8lc00042e] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
In almost any branch of chemistry or life sciences, it is often necessary to study the interaction between different components in a system by varying their respective concentrations in a systematic manner. Currently, many procedures for generating a series of samples of different solute concentration levels are still done manually by dilution. To address this issue, we present herein a highly automated linear concentration gradient generator based on centrifugal microfluidics. The operation of this device is based on the use of multi-layered microfluidics in which individual fluidic samples to be mixed together are stored and metered in their respective layers before finally being transferred to a mixing chamber. To demonstrate the operation of this scheme, we have used the device to conduct antimicrobial susceptibility testing (AST). Firstly, DI water, ampicillin solution and E. coli suspension were loaded into the chambers in different layers. As the device went through several rounds of spinning at different speeds, a series of metered dosages of ampicillin along a linear concentration gradient were introduced to the mixing chamber and mixed with E. coli automatically. By monitoring the spectral absorbance of the suspensions, we were able to establish the minimum inhibitory concentration (MIC) value of ampicillin against E. coli. The process took about 3 hours to complete, and the experimental results showed a strong correlation with those obtained with the standard CLSI broth dilution method. Clearly, the platform is useful for a wide range of applications such as drug discovery and personalised medicine, where concentration gradients are of concern.
Collapse
Affiliation(s)
- Minghui Tang
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong, China.
| | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Wang G, Tan J, Tang M, Zhang C, Zhang D, Ji W, Chen J, Ho HP, Zhang X. Binary centrifugal microfluidics enabling novel, digital addressable functions for valving and routing. LAB ON A CHIP 2018; 18:1197-1206. [PMID: 29546267 DOI: 10.1039/c8lc00026c] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Centrifugal microfluidics or lab-on-a-disc (LOAD) is a promising branch of lab-on-a-chip or microfluidics. Besides effective fluid transportation and inherently available density-based sample separation in centrifugal microfluidics, uniform actuation of flow on the disc makes the platform compact and scalable. However, the natural radially outward centrifugal force in a LOAD system limits its capacity to perform complex fluid manipulation steps. In order to increase the fluid manipulation freedom and integration capacity of the LOAD system, we propose a binary centrifugal microfluidics platform. With the help of Euler force, our platform allows free switching of both left and right states based on a rather simple mechanical structure. The periodical switching of state would provide a "clock" signal for a sequence of droplet binary logic operations. With the binary state platform and the "clock" signal, we can accurately handle the droplet separately in each time step with a maximum main frequency of about 10 S s-1 (switching per second). Apart from droplet manipulations such as droplet generation and metering, we also demonstrate a series of droplet logic operations, such as binary valving, droplet routing and digital addressable droplet storage. Furthermore, complex bioassays such as the Bradford assay and DNA purification assay are demonstrated on a binary platform, which is totally impossible for a traditional LOAD system. Our binary platform largely improves the capability for logic operation on the LOAD platform, and it is a simple and promising approach for microfluidic lab-on-a-disc large-scale integration.
Collapse
Affiliation(s)
- Guanghui Wang
- College of Engineering and Applied Sciences, Nanjing University, Jiangsu 210093, China.
| | - Jie Tan
- College of Engineering and Applied Sciences, Nanjing University, Jiangsu 210093, China.
| | - Minghui Tang
- Department of Electronic Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong, P. R. China.
| | - Changbin Zhang
- Nanjing University of Chinese Medicine, Nanjing, P.R. China
| | - Dongying Zhang
- College of Engineering and Applied Sciences, Nanjing University, Jiangsu 210093, China.
| | - Wenbin Ji
- College of Engineering and Applied Sciences, Nanjing University, Jiangsu 210093, China.
| | - Junhao Chen
- Department of Clinical Laboratory, Gulou Hospital, Nanjing University, Jiangsu, China
| | - Ho-Pui Ho
- Department of Electronic Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong, P. R. China.
| | - Xuping Zhang
- College of Engineering and Applied Sciences, Nanjing University, Jiangsu 210093, China.
| |
Collapse
|