1
|
Banse SA, Jarrett CM, Robinson KJ, Blue BW, Shaw EL, Phillips PC. The egg-counter: a novel microfluidic platform for characterization of Caenorhabditis elegans egg-laying. LAB ON A CHIP 2024; 24:2975-2986. [PMID: 38738514 PMCID: PMC11131562 DOI: 10.1039/d3lc01073b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Accepted: 04/20/2024] [Indexed: 05/14/2024]
Abstract
Reproduction is a fundamental process that shapes the demography of every living organism yet is often difficult to assess with high precision in animals that produce large numbers of offspring. Here, we present a novel microfluidic research platform for studying Caenorhabditis elegans' egg-laying. The platform provides higher throughput than traditional solid-media behavioral assays while providing a very high degree of temporal resolution. Additionally, the environmental control enabled by microfluidic animal husbandry allows for experimental perturbations difficult to achieve with solid-media assays. We demonstrate the platform's utility by characterizing C. elegans egg-laying behavior at two commonly used temperatures, 15 and 20 °C. As expected, we observed a delayed onset of egg-laying at 15 °C degrees, consistent with published temperature effects on development rate. Additionally, as seen in solid media studies, egg laying output was higher under the canonical 20 °C conditions. While we validated the Egg-Counter with a study of temperature effects in wild-type animals, the platform is highly adaptable to any nematode egg-laying research where throughput or environmental control needs to be maximized without sacrificing temporal resolution.
Collapse
Affiliation(s)
- Stephen A Banse
- Institute of Ecology and Evolution, University of Oregon, Eugene, OR 97403, USA.
| | - Cody M Jarrett
- Institute of Ecology and Evolution, University of Oregon, Eugene, OR 97403, USA.
| | - Kristin J Robinson
- Institute of Ecology and Evolution, University of Oregon, Eugene, OR 97403, USA.
| | - Benjamin W Blue
- Institute of Ecology and Evolution, University of Oregon, Eugene, OR 97403, USA.
| | - Emily L Shaw
- Institute of Ecology and Evolution, University of Oregon, Eugene, OR 97403, USA.
| | - Patrick C Phillips
- Institute of Ecology and Evolution, University of Oregon, Eugene, OR 97403, USA.
| |
Collapse
|
2
|
Banse SA, Jarrett CM, Robinson KJ, Blue BW, Shaw EL, Phillips PC. The Egg-Counter: A novel microfluidic platform for characterization of Caenorhabditis elegans egg-laying. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.09.01.555781. [PMID: 37732270 PMCID: PMC10508723 DOI: 10.1101/2023.09.01.555781] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/22/2023]
Abstract
Reproduction is a fundamental process that shapes the demography of every living organism yet is often difficult to assess with high precision in animals that produce large numbers of offspring. Here, we present a novel microfluidic research platform for studying Caenorhabditis elegans' egg-laying. The platform provides higher throughput than traditional solid-media assays while providing a very high degree of temporal resolution. Additionally, the environmental control enabled by microfluidic animal husbandry allows for experimental perturbations difficult to achieve with solid-media assays. We demonstrate the platform's utility by characterizing C. elegans egg-laying behavior at two commonly used temperatures, 15 and 20°C. As expected, we observed a delayed onset of egg-laying at 15°C degrees, consistent with published temperature effects on development rate. Additionally, as seen in solid media studies, egg laying output was higher under the canonical 20°C conditions. While we validated the Egg-Counter with a study of temperature effects in wild-type animals, the platform is highly adaptable to any nematode egg-laying research where throughput or environmental control needs to be maximized without sacrificing temporal resolution.
Collapse
Affiliation(s)
- Stephen A. Banse
- Institute of Ecology and Evolution, University of Oregon, Eugene, OR 97403, USA
| | - Cody M. Jarrett
- Institute of Ecology and Evolution, University of Oregon, Eugene, OR 97403, USA
| | - Kristin J. Robinson
- Institute of Ecology and Evolution, University of Oregon, Eugene, OR 97403, USA
| | - Benjamin W. Blue
- Institute of Ecology and Evolution, University of Oregon, Eugene, OR 97403, USA
| | - Emily L. Shaw
- Institute of Ecology and Evolution, University of Oregon, Eugene, OR 97403, USA
| | - Patrick C. Phillips
- Institute of Ecology and Evolution, University of Oregon, Eugene, OR 97403, USA
| |
Collapse
|
3
|
Tirgar P, Sarmadi F, Najafi M, Kazemi P, AzizMohseni S, Fayazi S, Zandi G, Ziaie N, Shoushtari Zadeh Naseri A, Ehrlicher A, Dashtizad M. Toward embryo cryopreservation-on-a-chip: A standalone microfluidic platform for gradual loading of cryoprotectants to minimize cryoinjuries. BIOMICROFLUIDICS 2021; 15:034104. [PMID: 34025896 PMCID: PMC8133792 DOI: 10.1063/5.0047185] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Accepted: 04/08/2021] [Indexed: 05/31/2023]
Abstract
Embryo vitrification is a fundamental practice in assisted reproduction and fertility preservation. A key step of this process is replacing the internal water with cryoprotectants (CPAs) by transferring embryos from an isotonic to a hypertonic solution of CPAs. However, this applies an abrupt osmotic shock to embryos, resulting in molecular damages that have long been a source of concern. In this study, we introduce a standalone microfluidic system to automate the manual process and minimize the osmotic shock applied to embryos. This device provides the same final CPA concentrations as the manual method but with a gradual increase over time instead of sudden increases. Our system allows the introduction of the dehydrating non-permeating CPA, sucrose, from the onset of CPA-water exchange, which in turn reduced the required time of CPA loading for successful vitrification without compromising its outcomes. We compared the efficacy of our device and the conventional manual procedure by studying vitrified-warmed mouse blastocysts based on their re-expansion and hatching rates and transcription pattern of selected genes involved in endoplasmic reticulum stress, oxidative stress, heat shock, and apoptosis. While both groups of embryos showed comparable re-expansion and hatching rates, on-chip loading reduced the detrimental gene expression of cryopreservation. The device developed here allowed us to automate the CPA loading process and push the boundaries of cryopreservation by minimizing its osmotic stress, shortening the overall process, and reducing its molecular footprint.
Collapse
Affiliation(s)
| | | | - Mojgan Najafi
- Embryo Biotechnology Laboratory (EmBio Lab), Department of Animal Biotechnology, National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran 1497716316, Iran
| | | | | | - Samaneh Fayazi
- Embryo Biotechnology Laboratory (EmBio Lab), Department of Animal Biotechnology, National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran 1497716316, Iran
| | - Ghazaleh Zandi
- Embryo Biotechnology Laboratory (EmBio Lab), Department of Animal Biotechnology, National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran 1497716316, Iran
| | - Nikta Ziaie
- Embryo Biotechnology Laboratory (EmBio Lab), Department of Animal Biotechnology, National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran 1497716316, Iran
| | - Aida Shoushtari Zadeh Naseri
- Embryo Biotechnology Laboratory (EmBio Lab), Department of Animal Biotechnology, National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran 1497716316, Iran
| | - Allen Ehrlicher
- Department of Bioengineering, McGill University, Montreal, Quebec H3A0B9, Canada
| | - Mojtaba Dashtizad
- Embryo Biotechnology Laboratory (EmBio Lab), Department of Animal Biotechnology, National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran 1497716316, Iran
| |
Collapse
|
4
|
Sofela S, Sahloul S, Bhattacharjee S, Bose A, Usman U, Song YA. Quantitative fluorescence imaging of mitochondria in body wall muscles of Caenorhabditis elegans under hyperglycemic conditions using a microfluidic chip. Integr Biol (Camb) 2020; 12:150-160. [DOI: 10.1093/intbio/zyaa011] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2019] [Revised: 03/15/2020] [Accepted: 04/28/2020] [Indexed: 12/25/2022]
Abstract
Abstract
Type 2 diabetes is the most common metabolic disease, and insulin resistance plays a role in the pathogenesis of the disease. Because completely functional mitochondria are necessary to obtain glucose-stimulated insulin from pancreatic beta cells, dysfunction of mitochondrial oxidative pathway could be involved in the development of diabetes. As a simple animal model, Caenorhabditis elegans renders itself to investigate such metabolic mechanisms because it possesses insulin/insulin-like growth factor-1 signaling pathway similar to that in humans. Currently, the widely spread agarose pad-based immobilization technique for fluorescence imaging of the mitochondria in C. elegans is laborious, batchwise, and does not allow for facile handling of the worm. To overcome these technical challenges, we have developed a single-channel microfluidic device that can trap a C. elegans and allow to image the mitochondria in body wall muscles accurately and in higher throughput than the traditional approach. In specific, our microfluidic device took advantage of the proprioception of the worm to rotate its body in a microfluidic channel with an aspect ratio above one to gain more space for its undulation motion that was favorable for quantitative fluorescence imaging of mitochondria in the body wall muscles. Exploiting this unique feature of the microfluidic chip-based immobilization and fluorescence imaging, we observed a significant decrease in the mitochondrial fluorescence intensity under hyperglycemic conditions, whereas the agarose pad-based approach did not show any significant change under the same conditions. A machine learning model trained with these fluorescence images from the microfluidic device could classify healthy and hyperglycemic worms at high accuracy. Given this significant technological advantage, its easiness of use and low cost, our microfluidic imaging chip could become a useful immobilization tool for quantitative fluorescence imaging of the body wall muscles in C. elegans.
Collapse
Affiliation(s)
- Samuel Sofela
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, United Arab Emirates
- Tandon School of Engineering, New York University, Brooklyn, NY, USA
| | - Sarah Sahloul
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, United Arab Emirates
| | - Sukanta Bhattacharjee
- Department of Computer Science and Engineering, Indian Institute of Technology Guwahati, Guwahati, India
| | - Ambar Bose
- Kallistos Infotech Private Limited, Kolkata, India
| | - Ushna Usman
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, United Arab Emirates
| | - Yong-Ak Song
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, United Arab Emirates
- Tandon School of Engineering, New York University, Brooklyn, NY, USA
| |
Collapse
|
5
|
Arata Y, Oshima T, Ikeda Y, Kimura H, Sako Y. OP50, a bacterial strain conventionally used as food for laboratory maintenance of C. elegans, is a biofilm formation defective mutant. MICROPUBLICATION BIOLOGY 2020; 2020. [PMID: 32550510 PMCID: PMC7252395 DOI: 10.17912/micropub.biology.000216] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Yukinobu Arata
- Cellular Informatics Laboratory, RIKEN, 2-1 Wako, Saitama, 351-0198, Japan
| | - Taku Oshima
- Department of Biotechnology, Toyama Prefectural University, 5180 Kurokawa, Imizu, Toyama 939-0398, Japan
| | - Yusaku Ikeda
- Cellular Informatics Laboratory, RIKEN, 2-1 Wako, Saitama, 351-0198, Japan.,Department of Mechanical Engineering, School of Engineering, Tokai University, 4-1-1 Kitakaname, Hiratsuka, Kanagawa 259-1292, Japan
| | - Hiroshi Kimura
- Department of Mechanical Engineering, School of Engineering, Tokai University, 4-1-1 Kitakaname, Hiratsuka, Kanagawa 259-1292, Japan
| | - Yasushi Sako
- Cellular Informatics Laboratory, RIKEN, 2-1 Wako, Saitama, 351-0198, Japan
| |
Collapse
|
6
|
Breimann L, Preusser F, Preibisch S. Light-microscopy methods in C. elegans research. ACTA ACUST UNITED AC 2019. [DOI: 10.1016/j.coisb.2018.11.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
7
|
Worms on a Chip. Bioanalysis 2019. [DOI: 10.1007/978-981-13-6229-3_6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
|
8
|
Zhao Y, Long L, Xu W, Campbell RF, Large EE, Greene JS, McGrath PT. Changes to social feeding behaviors are not sufficient for fitness gains of the Caenorhabditis elegans N2 reference strain. eLife 2018; 7:38675. [PMID: 30328811 PMCID: PMC6224195 DOI: 10.7554/elife.38675] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2018] [Accepted: 10/15/2018] [Indexed: 12/15/2022] Open
Abstract
The standard reference Caenorhabditis elegans strain, N2, has evolved marked behavioral changes in social feeding behavior since its isolation from the wild. We show that the causal, laboratory-derived mutations in two genes, npr-1 and glb-5, confer large fitness advantages in standard laboratory conditions. Using environmental manipulations that suppress social/solitary behavior differences, we show the fitness advantages of the derived alleles remained unchanged, suggesting selection on these alleles acted through pleiotropic traits. Transcriptomics, developmental timing, and food consumption assays showed that N2 animals mature faster, produce more sperm, and consume more food than a strain containing ancestral alleles of these genes regardless of behavioral strategies. Our data suggest that the pleiotropic effects of glb-5 and npr-1 are a consequence of changes to O2 -sensing neurons that regulate both aerotaxis and energy homeostasis. Our results demonstrate how pleiotropy can lead to profound behavioral changes in a popular laboratory model. Why do humans walk on two feet? And what makes us smarter than our ape ancestors? The answers to these questions, and countless others about the particular traits of any number of species, is often said to be natural selection – a process where genes that ensure the survival of a species are favored of others. But it is not always the answer. Other evolutionary forces, such as random changes to the frequency of certain gene variants, restrictions on the development of a certain trait and pleiotropy (where one gene influences other, seemingly unrelated traits) can also cause differences between species. Designing experiments to test whether a trait difference is due to natural selection or other factors is notoriously difficult. However, the humble nematode worm, Caenorhabditis elegans, has proven to be particularly useful in this respect. One subtype or strain of C. elegans with certain changes to its genes is used internationally as a ‘reference strain’, to ensure results between labs are comparable. This strain, N2, has been bred in the laboratory for hundreds of generations, isolated from its wild counterparts. N2 shows several differences in behavior from the wildtype, including its feeding habits. Wild C. elegans tend to feed together socially, whereas N2 prefers to feed alone. In 1998 and 2009, researchers – including some involved in the current study – have identified the genetic modifications responsible for this change in behavior. Now, Zhao et al. set out to determine whether this was due to natural selection, and if so, was there a benefit to solitary feeding in laboratory conditions that was driving this genetic change? Zhao et al. found that the genetic changes in the N2 strain gave the worms a considerable advantage in the artificial environment. However, experiments to modify the conditions the animals grew in revealed that the solitary feeding habits were not necessary for the fitness advantage. In other words, the changes in feeding habits were a symptom of the genetic changes that gave N2 a selective advantage, but they were not the cause. In other words, the changes in feeding behavior were not a result of natural selection, but rather of pleiotropy. The findings highlight that not every change in a trait is down to natural selection and must therefore be put to the test. With declining costs of DNA sequencing, researchers can now easily identify genes and regions of DNA that are likely to be under selection. However, they must be careful before leaping to the conclusion that behavioral differences linked to genetic changes are adaptive. In addition, the findings show that the laboratories relying on N2 as a model organism should be aware that the strain has evolved fundamental differences in its brain connections compared with the wildtype.
Collapse
Affiliation(s)
- Yuehui Zhao
- Department of Biological Sciences, Georgia Institute of Technology, Atlanta, United States
| | - Lijiang Long
- Department of Biological Sciences, Georgia Institute of Technology, Atlanta, United States
| | - Wen Xu
- Department of Biological Sciences, Georgia Institute of Technology, Atlanta, United States
| | - Richard F Campbell
- Department of Biological Sciences, Georgia Institute of Technology, Atlanta, United States
| | - Edward E Large
- Department of Biological Sciences, Georgia Institute of Technology, Atlanta, United States
| | | | - Patrick T McGrath
- Department of Biological Sciences, Georgia Institute of Technology, Atlanta, United States.,Department of Physics, Georgia Institute of Technology, Atlanta, United States.,Institute of Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, United States
| |
Collapse
|
9
|
Cornaglia M, Lehnert T, Gijs MAM. Microfluidic systems for high-throughput and high-content screening using the nematode Caenorhabditis elegans. LAB ON A CHIP 2017; 17:3736-3759. [PMID: 28840220 DOI: 10.1039/c7lc00509a] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
In a typical high-throughput drug screening (HTS) process, up to millions of chemical compounds are applied to cells cultured in well plates, aiming to find molecules that exhibit a robust dose-response, as evidenced for example by a fluorescence signal. In high-content screening (HCS), one goes a step further by linking the tested compounds to phenotypic information, obtained, for instance, from microscopic cell images, thereby creating richer data sets that also require more advanced analysis methods. The nematode Caenorhabditis elegans came into the screening picture due to the wide availability of its mutants and human disease models, its relatively easy culture and short life cycle. Being a whole-organism model, it allows drug testing under physiological conditions at multi-tissue levels and provides additional observable phenotypes with respect to cell models, related, for instance, to development, aging, behavior or motility. Worm-based HTS studies in liquid environments on microwell plates have been demonstrated, while microfluidic devices allowed surpassing the performance of plates by enabling more versatile and accurate assays, precise and dynamic dosing of compounds, and readouts down to single-animal resolution. In this review, we discuss microfluidic devices for C. elegans analysis and related studies, published in the period from 2012 to 2017. After an introduction to the different screening approaches, we first focus on microfluidic systems with potential for screening applications. Various enabling technologies, e.g. electrophysiological on-chip recordings or laser axotomy, have been implemented, as well as techniques for reversible worm immobilization and high-resolution imaging, combined with algorithms for automated experimentation and analysis. Several devices for developmental or behavioral assays, and worm sorting based on different phenotypes, have been proposed too. In a subsequent section, we review the application of microfluidic-based systems for medium- and high-throughput screens, including neurobiology and neurodegeneration studies, aging and developmental assays, toxicity and pathogenesis screens, as well as behavioral and motility assays. A thorough analysis of this work reveals a trend towards microfluidic systems more and more capable of offering high-quality analyses of large worm populations, based on multi-phenotypic and/or longitudinal readouts, with clear potential for their application in larger HTS/HCS contexts.
Collapse
Affiliation(s)
- Matteo Cornaglia
- Laboratory of Microsystems, École Polytechnique Fédérale de Lausanne, Lausanne, CH-1015, Switzerland.
| | | | | |
Collapse
|