1
|
Garkal A, Kulkarni D, Musale S, Mehta T, Giram P. Electrospinning nanofiber technology: a multifaceted paradigm in biomedical applications. NEW J CHEM 2021. [DOI: 10.1039/d1nj04159b] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
This review focuses on the process of preparation of nanofibers via Es, the design and setup of the instrument, critical parameter optimization, preferable polymers, solvents, characterization techniques, and recent development and biomedical applications of nanofibers.
Collapse
Affiliation(s)
- Atul Garkal
- Department of Pharmaceutics, Institute of Pharmacy, Nirma University, Ahmedabad, Gujarat, 382481, India
| | - Deepak Kulkarni
- Department of Pharmaceutics, Srinath College of Pharmacy, Bajajnagar, Aurangabad, Maharashtra, 431136, India
| | - Shubham Musale
- Department of Pharmaceutics, Dr D.Y. Patil Institute of Pharmaceutical Sciences and Research, Pimpri-Pune, Maharashtra, 411018, India
| | - Tejal Mehta
- Department of Pharmaceutics, Institute of Pharmacy, Nirma University, Ahmedabad, Gujarat, 382481, India
| | - Prabhanjan Giram
- Department of Pharmaceutics, Dr D.Y. Patil Institute of Pharmaceutical Sciences and Research, Pimpri-Pune, Maharashtra, 411018, India
| |
Collapse
|
2
|
Wang C, Li Z, Zhang L, Sun W, Zhou J. Long-term results of triple-layered small diameter vascular grafts in sheep carotid arteries. Med Eng Phys 2020; 85:1-6. [PMID: 33081956 DOI: 10.1016/j.medengphy.2020.09.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2020] [Revised: 06/23/2020] [Accepted: 09/16/2020] [Indexed: 12/15/2022]
Abstract
There is an urgent clinical for small diameter vascular grafts (SDVGs) for use in the treatment of coronary artery disease. Moreover, biodegradable SDVGs are drawing increasing attention because they have the potential to restore vascular function with the degradation of vascular graft and tissue regeneration. In this study, we designed triple-layered SDVGs to mimic the native arterial structure, with each layer contributing its unique porosity to the porous structure. We evaluated triple-layered SDVGs in a sheep carotid arterial replacement model. After implantation for 12 months, two grafts were patent and indicated the feasibility of using grafts in large animals. Nevertheless, it was determined that both grafts formed aneurysms at the proximal end. The prevention of such aneurysms remains a challenge for future investigation.
Collapse
Affiliation(s)
- Chengjin Wang
- Biomanufacturing Center, Department of Mechanical Engineering, Tsinghua University, Beijing 100084, P R China; Biomanufacturing and Rapid Forming Technology Key Laboratory of Beijing, Beijing 100084, P R China; "Biomanufacturing and Engineering Living Systems" Innovation International Talents Base (111 Base), Beijing 100084, P R China
| | - Zhen Li
- Biomanufacturing Center, Department of Mechanical Engineering, Tsinghua University, Beijing 100084, P R China; Biomanufacturing and Rapid Forming Technology Key Laboratory of Beijing, Beijing 100084, P R China; "Biomanufacturing and Engineering Living Systems" Innovation International Talents Base (111 Base), Beijing 100084, P R China
| | - Lei Zhang
- Biomanufacturing Center, Department of Mechanical Engineering, Tsinghua University, Beijing 100084, P R China; Biomanufacturing and Rapid Forming Technology Key Laboratory of Beijing, Beijing 100084, P R China; "Biomanufacturing and Engineering Living Systems" Innovation International Talents Base (111 Base), Beijing 100084, P R China.
| | - Wei Sun
- Biomanufacturing Center, Department of Mechanical Engineering, Tsinghua University, Beijing 100084, P R China; Biomanufacturing and Rapid Forming Technology Key Laboratory of Beijing, Beijing 100084, P R China; "Biomanufacturing and Engineering Living Systems" Innovation International Talents Base (111 Base), Beijing 100084, P R China; Department of Mechanical Engineering, Drexel University, Philadelphia, PA, United States
| | - Jianye Zhou
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, P R China
| |
Collapse
|
3
|
Shi J, Zhang J, Yin M, Wang Q, Du J. Accurate and continuous ultrasonography evaluation of small diameter vascular prostheses in vivo. Exp Ther Med 2018; 15:3899-3907. [PMID: 29563986 PMCID: PMC5858090 DOI: 10.3892/etm.2018.5895] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2017] [Accepted: 01/05/2018] [Indexed: 11/24/2022] Open
Abstract
There is a large clinical requirement for novel vascular grafts; however, the development of novel vascular grafts has not been extremely successful to date. The most successful method for the continuous evaluation of vascular grafts in vivo remains unclear. Therefore, an optimal successive, non-invasive imaging modality is necessary for the study of vascular transplantation. In the present study, a common rabbit model of carotid artery defect was utilized. The patency and hemodynamic characteristics of implanted grafts was examined following surgery by color Doppler ultrasound in three modes, including B-mode, color flow map and pulse-Doppler examination. The results revealed that ultrasound had sufficient spatial resolution to generate clear images of the carotid artery of rabbits with or without the implanted grafts. Color Doppler ultrasound may be applied to evaluate and differentiate the patent, stenosis and occlusion of carotid arteries in rabbits with different vascular grafts implanted. Furthermore, color Doppler ultrasound is an optimal imaging modality for continuous evaluation in vivo. It is also possible for some quantitative analyses to be performed, including measuring the diameter of vascular lumens and the flow velocity of the region of interest. The present study suggests vascular ultrasound as the optimum choice for continuous surveillance of vascular prostheses in vivo, which may provide valuable information about the grafts in order to greatly shorten the experimental period.
Collapse
Affiliation(s)
- Jing Shi
- Imaging Diagnosis Center, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, P.R. China
| | - Jialing Zhang
- Department of Cardiothoracic Surgery, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, P.R. China
| | - Meng Yin
- Department of Cardiothoracic Surgery, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, P.R. China
| | - Qian Wang
- Imaging Diagnosis Center, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, P.R. China
| | - Jun Du
- Imaging Diagnosis Center, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, P.R. China
| |
Collapse
|
4
|
Wu T, Zhang J, Wang Y, Li D, Sun B, El-Hamshary H, Yin M, Mo X. Fabrication and preliminary study of a biomimetic tri-layer tubular graft based on fibers and fiber yarns for vascular tissue engineering. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 82:121-129. [PMID: 29025640 DOI: 10.1016/j.msec.2017.08.072] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2017] [Revised: 08/13/2017] [Accepted: 08/16/2017] [Indexed: 11/25/2022]
Abstract
Designing a biomimetic and functional tissue-engineered vascular graft has been urgently needed for repairing and regenerating defected vascular tissues. Utilizing a multi-layered vascular scaffold is commonly considered an effective way, because multi-layered scaffolds can easily simulate the structure and function of natural blood vessels. Herein, we developed a novel tri-layer tubular graft consisted of Poly(L-lactide-co-caprolactone)/collagen (PLCL/COL) fibers and Poly(lactide-co-glycolide)/silk fibroin (PLGA/SF) yarns via a three-step electrospinning method. The tri-layer vascular graft consisted of PLCL/COL aligned fibers in inner layer, PLGA/SF yarns in middle layer, and PLCL/COL random fibers in outer layer. Each layer possessed tensile mechanical strength and elongation, and the entire tubular structure provided tensile and compressive supports. Furthermore, the human umbilical vein endothelial cells (HUVECs) and smooth muscle cells (SMCs) proliferated well on the materials. Fluorescence staining images demonstrated that the axially aligned PLCL/COL fibers prearranged endothelium morphology in lumen and the circumferential oriented PLGA/SF yarns regulated SMCs organization along the single yarns. The outside PLCL/COL random fibers performed as the fixed layer to hold the entire tubular structure. The in vivo results showed that the tri-layer vascular graft supported cell infiltration, scaffold biodegradation and abundant collagen production after subcutaneous implantation for 10weeks, revealing the optimal biocompatibility and tissue regenerative capability of the tri-layer graft. Therefore, the specially designed tri-layer vascular graft will be beneficial to vascular reconstruction.
Collapse
Affiliation(s)
- Tong Wu
- State Key Lab for Modification of Chemical Fibers and Polymer Materials, College of Chemistry, Chemical Engineering and Biotechnology, Donghua University, Shanghai 201620, China
| | - Jialing Zhang
- Department of Cardiothoracic Surgery, Shanghai Children's Medical Center, Shanghai Jiaotong University School of Medicine, Shanghai 200127, China
| | - Yuanfei Wang
- State Key Laboratory of Bioreactor Engineering, School of Resources and Environmental Engineering, East China University of Science and Technology, Shanghai 200237, China
| | - Dandan Li
- College of Material Science and Engineering, Donghua University, Shanghai 201620, China
| | - Binbin Sun
- State Key Lab for Modification of Chemical Fibers and Polymer Materials, College of Chemistry, Chemical Engineering and Biotechnology, Donghua University, Shanghai 201620, China
| | - Hany El-Hamshary
- Department of Chemistry, College of Science, King Saud University, Riyadh 11451, Saudi Arabia; Department of Chemistry, Faculty of Science, Tanta University, Tanta 31527, Egypt
| | - Meng Yin
- Department of Cardiothoracic Surgery, Shanghai Children's Medical Center, Shanghai Jiaotong University School of Medicine, Shanghai 200127, China.
| | - Xiumei Mo
- State Key Lab for Modification of Chemical Fibers and Polymer Materials, College of Chemistry, Chemical Engineering and Biotechnology, Donghua University, Shanghai 201620, China.
| |
Collapse
|