1
|
Werner J, Belz M, Klein KF, Sun T, Grattan KTV. Characterization of a fast response fiber-optic pH sensor and illustration in a biological application. Analyst 2021; 146:4811-4821. [PMID: 34195717 DOI: 10.1039/d1an00631b] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Optical, and especially fiber-optic techniques for the sensing of pH have become very attractive and considerable research progress in this field has been made over recent years. The determination of the value of pH across a broad range of applications today, important for areas of study such as life sciences, environmental monitoring, manufacturing industry and widely in biological research is now accessible from such optical sensors. The need for such technology arises because familiar, commercial sensors are often limited in terms of their response time and the presence of drift, all of which emphasize the value of newer and rapidly developing technologies such as fiber-optic sensors, to address these wider applications. As a result, a new compact sensor design has been developed, designed around a specially-formed fiber-optic tip, coated with a pH-sensitive dye, and importantly covalently linked to a hydrogel matrix to provide high stability. The sensor developed was designed to have a very fast response time (to 90% of saturation, Δt90) of <5 s and a sensing uncertainty of ∼±0.04 pH units. Given the covalently bonded nature of the dye, the problem of leaching of the indicator dye is reduced, creating a probe which has been shown to be very stable over many days of use. Illustrating this through extended continuous use, over ∼12 h at pH 7, this stability was confirmed showing a drift of <0.05 pH h-1. In order to give an illustration of the value of the probe in an important biological application, the monitoring of pH levels between pH 7 to pH 8 in an AMES' medium, a substance which is important to maintain the metabolism of retinal cells is shown and the results as well as temperature stability of the probe discussed.
Collapse
Affiliation(s)
- Jan Werner
- School of Mathematics, Computer Science and Engineering, City, University of London, Northampton Square, EC1 V 0HB, London, UK.
| | | | | | | | | |
Collapse
|
2
|
Steinegger A, Wolfbeis OS, Borisov SM. Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications. Chem Rev 2020; 120:12357-12489. [PMID: 33147405 PMCID: PMC7705895 DOI: 10.1021/acs.chemrev.0c00451] [Citation(s) in RCA: 189] [Impact Index Per Article: 37.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Indexed: 12/13/2022]
Abstract
This is the first comprehensive review on methods and materials for use in optical sensing of pH values and on applications of such sensors. The Review starts with an introduction that contains subsections on the definition of the pH value, a brief look back on optical methods for sensing of pH, on the effects of ionic strength on pH values and pKa values, on the selectivity, sensitivity, precision, dynamic ranges, and temperature dependence of such sensors. Commonly used optical sensing schemes are covered in a next main chapter, with subsections on methods based on absorptiometry, reflectometry, luminescence, refractive index, surface plasmon resonance, photonic crystals, turbidity, mechanical displacement, interferometry, and solvatochromism. This is followed by sections on absorptiometric and luminescent molecular probes for use pH in sensors. Further large sections cover polymeric hosts and supports, and methods for immobilization of indicator dyes. Further and more specific sections summarize the state of the art in materials with dual functionality (indicator and host), nanomaterials, sensors based on upconversion and 2-photon absorption, multiparameter sensors, imaging, and sensors for extreme pH values. A chapter on the many sensing formats has subsections on planar, fiber optic, evanescent wave, refractive index, surface plasmon resonance and holography based sensor designs, and on distributed sensing. Another section summarizes selected applications in areas, such as medicine, biology, oceanography, bioprocess monitoring, corrosion studies, on the use of pH sensors as transducers in biosensors and chemical sensors, and their integration into flow-injection analyzers, microfluidic devices, and lab-on-a-chip systems. An extra section is devoted to current challenges, with subsections on challenges of general nature and those of specific nature. A concluding section gives an outlook on potential future trends and perspectives.
Collapse
Affiliation(s)
- Andreas Steinegger
- Institute
of Analytical Chemistry and Food Chemistry, Graz University of Technology, Stremayrgasse 9, A-8010 Graz, Austria
| | - Otto S. Wolfbeis
- Institute
of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, D-93040 Regensburg, Germany
| | - Sergey M. Borisov
- Institute
of Analytical Chemistry and Food Chemistry, Graz University of Technology, Stremayrgasse 9, A-8010 Graz, Austria
| |
Collapse
|
3
|
Ehrlich K, Choudhary TR, Ucuncu M, Megia-Fernandez A, Harrington K, Wood HAC, Yu F, Choudhury D, Dhaliwal K, Bradley M, Tanner MG. Time-Resolved Spectroscopy of Fluorescence Quenching in Optical Fibre-Based pH Sensors. SENSORS 2020; 20:s20216115. [PMID: 33121191 PMCID: PMC7663438 DOI: 10.3390/s20216115] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Revised: 10/13/2020] [Accepted: 10/20/2020] [Indexed: 12/20/2022]
Abstract
Numerous optodes, with fluorophores as the chemical sensing element and optical fibres for light delivery and collection, have been fabricated for minimally invasive endoscopic measurements of key physiological parameters such as pH. These flexible miniaturised optodes have typically attempted to maximize signal-to-noise through the application of high concentrations of fluorophores. We show that high-density attachment of carboxyfluorescein onto silica microspheres, the sensing elements, results in fluorescence energy transfer, manifesting as reduced fluorescence intensity and lifetime in addition to spectral changes. We demonstrate that the change in fluorescence intensity of carboxyfluorescein with pH in this "high-density" regime is opposite to that normally observed, with complex variations in fluorescent lifetime across the emission spectra of coupled fluorophores. Improved understanding of such highly loaded sensor beads is important because it leads to large increases in photostability and will aid the development of compact fibre probes, suitable for clinical applications. The time-resolved spectral measurement techniques presented here can be further applied to similar studies of other optodes.
Collapse
Affiliation(s)
- Katjana Ehrlich
- Scottish Universities Physics Alliance (SUPA), Institute of Photonics and Quantum Sciences, Heriot-Watt University, Edinburgh EH14 4AS, UK; (D.C.); (M.G.T.)
- EPSRC Proteus IRC Hub, Centre for Inflammation Research, Queen’s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ, UK; (T.R.C.); (K.D.); (M.B.)
- Correspondence:
| | - Tushar R. Choudhary
- EPSRC Proteus IRC Hub, Centre for Inflammation Research, Queen’s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ, UK; (T.R.C.); (K.D.); (M.B.)
- Institute of Biological Chemistry, Biophysics and Bioengineering, School of Engineering & Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS, UK
| | - Muhammed Ucuncu
- School of Chemistry, EaStChem, University of Edinburgh, Joseph Black Building, West Mains Road, Edinburgh EH9 3FF, UK; (M.U.); (A.M.-F.)
| | - Alicia Megia-Fernandez
- School of Chemistry, EaStChem, University of Edinburgh, Joseph Black Building, West Mains Road, Edinburgh EH9 3FF, UK; (M.U.); (A.M.-F.)
| | - Kerrianne Harrington
- Centre for Photonics and Photonic Materials, University of Bath, Claverton Down, Bath BA27AY, UK; (K.H.); (H.A.C.W.); (F.Y.)
| | - Harry A. C. Wood
- Centre for Photonics and Photonic Materials, University of Bath, Claverton Down, Bath BA27AY, UK; (K.H.); (H.A.C.W.); (F.Y.)
| | - Fei Yu
- Centre for Photonics and Photonic Materials, University of Bath, Claverton Down, Bath BA27AY, UK; (K.H.); (H.A.C.W.); (F.Y.)
| | - Debaditya Choudhury
- Scottish Universities Physics Alliance (SUPA), Institute of Photonics and Quantum Sciences, Heriot-Watt University, Edinburgh EH14 4AS, UK; (D.C.); (M.G.T.)
| | - Kev Dhaliwal
- EPSRC Proteus IRC Hub, Centre for Inflammation Research, Queen’s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ, UK; (T.R.C.); (K.D.); (M.B.)
| | - Mark Bradley
- EPSRC Proteus IRC Hub, Centre for Inflammation Research, Queen’s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ, UK; (T.R.C.); (K.D.); (M.B.)
- School of Chemistry, EaStChem, University of Edinburgh, Joseph Black Building, West Mains Road, Edinburgh EH9 3FF, UK; (M.U.); (A.M.-F.)
| | - Michael G. Tanner
- Scottish Universities Physics Alliance (SUPA), Institute of Photonics and Quantum Sciences, Heriot-Watt University, Edinburgh EH14 4AS, UK; (D.C.); (M.G.T.)
- EPSRC Proteus IRC Hub, Centre for Inflammation Research, Queen’s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ, UK; (T.R.C.); (K.D.); (M.B.)
| |
Collapse
|
4
|
Gong J, Tanner MG, Venkateswaran S, Stone JM, Zhang Y, Bradley M. A hydrogel-based optical fibre fluorescent pH sensor for observing lung tumor tissue acidity. Anal Chim Acta 2020; 1134:136-143. [PMID: 33059859 DOI: 10.1016/j.aca.2020.07.063] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 07/10/2020] [Accepted: 07/23/2020] [Indexed: 02/08/2023]
Abstract
Technologies for measuring physiological parameters in vivo offer the possibility of the detection of disease and its progression due to the resulting changes in tissue pH, or temperature, etc.. Here, a compact hydrogel-based optical fibre pH sensor was fabricated, in which polymer microarrays were utilized for the high-throughput discovery of an optimal matrix for pH indicator immobilization. The fabricated hydrogel-based probe responded rapidly to pH changes and demonstrated a good linear correlation within the physiological pH range (from 5.5 to 8.0) with a precision of 0.10 pH units. This miniature probe was validated by measuring pH across a whole ovine lung and allowed discrimination of tumorous and normal tissue, thus offering the potential for the rapid and accurate observation of tissue pH changes.
Collapse
Affiliation(s)
- Jingjing Gong
- School of Chemistry, EaStCHEM, University of Edinburgh, King's Buildings, West Mains Road, Edinburgh, EH9 3FJ, UK; EPSRC Proteus Hub, Centre for Inflammation Research, Queen's Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh, EH16 4TJ, UK
| | - Michael G Tanner
- EPSRC Proteus Hub, Centre for Inflammation Research, Queen's Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh, EH16 4TJ, UK; Institute of Photonics and Quantum Sciences, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, EH14 4AS, UK
| | - Seshasailam Venkateswaran
- School of Chemistry, EaStCHEM, University of Edinburgh, King's Buildings, West Mains Road, Edinburgh, EH9 3FJ, UK
| | - James M Stone
- Centre for Photonics and Photonic Materials, Department of Physics, University of Bath, Bath, BA2 7AY, UK
| | - Yichuan Zhang
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Mark Bradley
- School of Chemistry, EaStCHEM, University of Edinburgh, King's Buildings, West Mains Road, Edinburgh, EH9 3FJ, UK; EPSRC Proteus Hub, Centre for Inflammation Research, Queen's Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh, EH16 4TJ, UK.
| |
Collapse
|
5
|
Kamaljith V, Tanner MG, Wood HAC, Harrington K, Choudhury D, Bradley M, Thomson RR. Ultrafast-laser-ablation-assisted spatially selective attachment of fluorescent sensors onto optical fibers. OPTICS LETTERS 2020; 45:2716-2719. [PMID: 32412449 DOI: 10.1364/ol.381018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2019] [Accepted: 12/08/2019] [Indexed: 06/11/2023]
Abstract
A robust method to selectively attach specific fluorophores onto the individual cores of a multicore fiber is reported in this Letter. The method is based on the use of ultrafast laser pulses to nanostructure the facet of the fiber core, followed by amine functionalization and sensor conjugation. This surface-machining protocol not only enables precise spatial selectivity, but it also facilitates high deposition densities of the sensor moieties. As a proof of concept, the successful deposition of three different fluorophores onto selected cores of a multicore fiber is demonstrated. The protocol was developed to include attachment of a fluorescence-based pH sensor using the ratiometric carboxynapthofluorescein.
Collapse
|
6
|
Affiliation(s)
- Xu-dong Wang
- Department of Chemistry, Fudan University, 200433 Shanghai, P. R. China
| | - Otto S. Wolfbeis
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, D-93040 Regensburg, Germany
| |
Collapse
|
7
|
High fidelity fibre-based physiological sensing deep in tissue. Sci Rep 2019; 9:7713. [PMID: 31118459 PMCID: PMC6531436 DOI: 10.1038/s41598-019-44077-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Accepted: 05/03/2019] [Indexed: 11/08/2022] Open
Abstract
Physiological sensing deep in tissue remains a clinical challenge. Here a flexible miniaturised sensing optrode providing a platform to perform minimally invasive in vivo in situ measurements is reported. Silica microspheres covalently coupled with a high density of ratiometrically configured fluorophores were deposited into etched pits on the distal end of a 150 µm diameter multicore optical fibre. With this platform, photonic measurements of pH and oxygen concentration with high precision in the distal alveolar space of the lung are reported. We demonstrated the phenomenon that high-density deposition of carboxyfluorescein covalently coupled to silica microspheres shows an inverse shift in fluorescence in response to varying pH. This platform delivered fast and accurate measurements (±0.02 pH units and ±0.6 mg/L of oxygen), near instantaneous response time and a flexible architecture for addition of multiple sensors.
Collapse
|
8
|
Gong J, Venkateswaran S, Tanner MG, Stone JM, Bradley M. Polymer Microarrays for the Discovery and Optimization of Robust Optical-Fiber-Based pH Sensors. ACS COMBINATORIAL SCIENCE 2019; 21:417-424. [PMID: 30973701 DOI: 10.1021/acscombsci.9b00031] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Polymer microarrays were utilized for the high-throughput screening and discovery of optimal polymeric substrates capable of trapping functional ratiometric fluorescence-based pH sensors. This led to the identification of poly(methyl methacrylate- co-2-(dimethylamino) ethyl acrylate) (PA101), which allowed, via dip coating, the attachment of fluorescent pH sensors onto the tips of optical fibers, resulting in robust, rapid, and reproducible sensing of physiological pHs.
Collapse
Affiliation(s)
- Jingjing Gong
- School of Chemsitry, EaStCHEM, University of Edinburgh, King’s Buildings, West Mains Road, Edinburgh EH9 3FJ, United Kingdom
- EPSRC Proteus Hub, Centre for Inflammation Research, Queen’s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ, United Kingdom
| | - Seshasailam Venkateswaran
- School of Chemsitry, EaStCHEM, University of Edinburgh, King’s Buildings, West Mains Road, Edinburgh EH9 3FJ, United Kingdom
| | - Michael G. Tanner
- Institute of Photonics and Quantum Sciences, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS, United Kingdom
- EPSRC Proteus Hub, Centre for Inflammation Research, Queen’s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ, United Kingdom
| | - James M. Stone
- Centre for Photonics and Photonic Materials, Department of Physics, University of Bath, Bath BA2 7AY, United Kingdom
- EPSRC Proteus Hub, Centre for Inflammation Research, Queen’s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ, United Kingdom
| | - Mark Bradley
- School of Chemsitry, EaStCHEM, University of Edinburgh, King’s Buildings, West Mains Road, Edinburgh EH9 3FJ, United Kingdom
- EPSRC Proteus Hub, Centre for Inflammation Research, Queen’s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ, United Kingdom
| |
Collapse
|
9
|
Cheng X, Bonefacino J, Guan BO, Tam HY. All-polymer fiber-optic pH sensor. OPTICS EXPRESS 2018; 26:14610-14616. [PMID: 29877495 DOI: 10.1364/oe.26.014610] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/16/2018] [Accepted: 05/14/2018] [Indexed: 06/08/2023]
Abstract
A novel all-polymer fiber-optic pH sensor using a UV-cured pH-sensitive hydrogel, poly(ethylene glycol) diacrylate (PEGDA), coated on a polymer fiber Bragg grating was developed. The PEGDA increased in volume according to the pH value of the surrounding fluid, which subsequently induced a lateral stress in the polymer fiber Bragg grating. The proposed pH sensor exhibits a pH sensitivity of up to -0.41 nm/pH and a fast response time of 30 s.
Collapse
|