1
|
Li Q, Wong HL, Ip YL, Chu WY, Li MS, Saha C, Shih KC, Chan YK. Current microfluidic platforms for reverse engineering of cornea. Mater Today Bio 2023; 20:100634. [PMID: 37139464 PMCID: PMC10149412 DOI: 10.1016/j.mtbio.2023.100634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 04/04/2023] [Accepted: 04/10/2023] [Indexed: 05/05/2023] Open
Abstract
According to the World Health Organization, corneal blindness constitutes 5.1% of global blindness population. Surgical outcomes have been improved significantly in the treatment of corneal blindness. However, corneal transplantation is limited by global shortage of donor tissue, prompting researchers to explore alternative therapies such as novel ocular pharmaceutics to delay corneal disease progression. Animal models are commonly adopted for investigating pharmacokinetics of ocular drugs. However, this approach is limited by physiological differences in the eye between animals and human, ethical issues and poor bench-to-bedside translatability. Cornea-on-a-chip (CoC) microfluidic platforms have gained great attention as one of the advanced in vitro strategies for constructing physiologically representative corneal models. With significant improvements in tissue engineering technology, CoC integrates corneal cells with microfluidics to recapitulate human corneal microenvironment for the study of corneal pathophysiological changes and evaluation of ocular drugs. Such model, in complement to animal studies, can potentially accelerate translational research, in particular the pre-clinical screening of ophthalmic medication, driving clinical treatment advancement for corneal diseases. This review provides an overview of engineered CoC platforms with respect to their merits, applications, and technical challenges. Emerging directions in CoC technology are also proposed for further investigations, to accentuate preclinical obstacles in corneal research.
Collapse
Affiliation(s)
- Qinyu Li
- Department of Ophthalmology, LKS Faculty of Medicine, The University of Hong Kong, 999077, Hong Kong, China
| | - Ho Lam Wong
- Department of Ophthalmology, LKS Faculty of Medicine, The University of Hong Kong, 999077, Hong Kong, China
| | - Yan Lam Ip
- Department of Ophthalmology, LKS Faculty of Medicine, The University of Hong Kong, 999077, Hong Kong, China
| | - Wang Yee Chu
- Department of Ophthalmology, LKS Faculty of Medicine, The University of Hong Kong, 999077, Hong Kong, China
| | - Man Shek Li
- Department of Ophthalmology, LKS Faculty of Medicine, The University of Hong Kong, 999077, Hong Kong, China
| | - Chinmoy Saha
- Department of Ophthalmology, LKS Faculty of Medicine, The University of Hong Kong, 999077, Hong Kong, China
| | - Kendrick Co Shih
- Department of Ophthalmology, LKS Faculty of Medicine, The University of Hong Kong, 999077, Hong Kong, China
| | - Yau Kei Chan
- Department of Ophthalmology, LKS Faculty of Medicine, The University of Hong Kong, 999077, Hong Kong, China
| |
Collapse
|
2
|
Wang N, Zhang Y, Wang W, Ye Z, Chen H, Hu G, Ouyang D. How can machine learning and multiscale modeling benefit ocular drug development? Adv Drug Deliv Rev 2023; 196:114772. [PMID: 36906232 DOI: 10.1016/j.addr.2023.114772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 02/06/2023] [Accepted: 03/05/2023] [Indexed: 03/12/2023]
Abstract
The eyes possess sophisticated physiological structures, diverse disease targets, limited drug delivery space, distinctive barriers, and complicated biomechanical processes, requiring a more in-depth understanding of the interactions between drug delivery systems and biological systems for ocular formulation development. However, the tiny size of the eyes makes sampling difficult and invasive studies costly and ethically constrained. Developing ocular formulations following conventional trial-and-error formulation and manufacturing process screening procedures is inefficient. Along with the popularity of computational pharmaceutics, non-invasive in silico modeling & simulation offer new opportunities for the paradigm shift of ocular formulation development. The current work first systematically reviews the theoretical underpinnings, advanced applications, and unique advantages of data-driven machine learning and multiscale simulation approaches represented by molecular simulation, mathematical modeling, and pharmacokinetic (PK)/pharmacodynamic (PD) modeling for ocular drug development. Following this, a new computer-driven framework for rational pharmaceutical formulation design is proposed, inspired by the potential of in silico explorations in understanding drug delivery details and facilitating drug formulation design. Lastly, to promote the paradigm shift, integrated in silico methodologies were highlighted, and discussions on data challenges, model practicality, personalized modeling, regulatory science, interdisciplinary collaboration, and talent training were conducted in detail with a view to achieving more efficient objective-oriented pharmaceutical formulation design.
Collapse
Affiliation(s)
- Nannan Wang
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences (ICMS), University of Macau, Macau, China
| | - Yunsen Zhang
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences (ICMS), University of Macau, Macau, China
| | - Wei Wang
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences (ICMS), University of Macau, Macau, China
| | - Zhuyifan Ye
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences (ICMS), University of Macau, Macau, China
| | - Hongyu Chen
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences (ICMS), University of Macau, Macau, China; Faculty of Science and Technology (FST), University of Macau, Macau, China
| | - Guanghui Hu
- Faculty of Science and Technology (FST), University of Macau, Macau, China
| | - Defang Ouyang
- State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences (ICMS), University of Macau, Macau, China; Department of Public Health and Medicinal Administration, Faculty of Health Sciences (FHS), University of Macau, Macau, China.
| |
Collapse
|
3
|
Helena Macedo M, Baião A, Pinto S, Barros AS, Almeida H, Almeida A, das Neves J, Sarmento B. Mucus-producing 3D cell culture models. Adv Drug Deliv Rev 2021; 178:113993. [PMID: 34619286 DOI: 10.1016/j.addr.2021.113993] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 08/23/2021] [Accepted: 09/29/2021] [Indexed: 10/20/2022]
Abstract
In vitro cell-based models have been used for a long time since they are normally easily obtained and have an advantageous cost-benefit. Besides, they can serve a variety of ends, from studying drug absorption and metabolism to disease modeling. However, some in vitro models are too simplistic, not accurately representing the living tissues. It has been shown, mainly in the last years, that fully mimicking a tissue composition and architecture can be paramount for cellular behavior and, consequently, for the outcomes of the studies using such models. Because of this, 3D in vitro cell models have been gaining much attention, since they are able to better replicate the in vivo environment. In this review we focus on 3D models that contain mucus-producing cells, as mucus can play a pivotal role in drug absorption. Being frequently overlooked, this viscous fluid can have an impact on drug delivery. Thus, the aim of this review is to understand to which extent can mucus affect mucosal drug delivery and to provide a state-of-the-art report on the existing 3D cell-based mucus models.
Collapse
|
4
|
Wong HL, Hung LT, Kwok SS, Bu Y, Lin Y, Shum HC, Wang H, Lo ACY, Yam GHF, Jhanji V, Shih KC, Chan YK. The anti-scarring role of Lycium barbarum polysaccharide on cornea epithelial-stromal injury. Exp Eye Res 2021; 211:108747. [PMID: 34450184 DOI: 10.1016/j.exer.2021.108747] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Revised: 08/07/2021] [Accepted: 08/22/2021] [Indexed: 12/16/2022]
Abstract
PURPOSE Cornea epithelial-stromal scarring is related to the differentiation of fibroblasts into opaque myofibroblasts. Our study aims to assess the effectiveness of Lycium barbarum polysaccharide (LBP) solution as a pre-treatment in minimizing corneal scarring. METHODS Human corneal fibroblasts were cultured in a three-dimensional collagen type I-based hydrogel in an eye-on-a-chip model. Fibroblasts were pre-treated with 2 mg/mL LBP for 24 h, followed by another 24-h incubation with 10 ng/mL transforming growth factor-beta 1 (TGF-β1) to induce relevant physiological events after stromal injury. Intracellular pro-fibrotic proteins, extracellular matrix proteins, and pro-inflammatory cytokines that involved in fibrosis, were assessed using immunocytochemistry and enzyme-linked immunosorbent assays. RESULTS Compared to the positive control TGF-β1 group, LBP pre-treated cells had a significantly lower expression of alpha-smooth muscle actin, marker of myofibroblasts, vimentin (p < 0.05), and also extracellular matrix proteins both collagen type II and type III (p < 0.05) that can be found in scar tissues. Moreover, LBP pre-treated cells had a significantly lower secretion of pro-inflammatory cytokines interleukin-6 and interleukin-8 (p < 0.05). The cell-laden hydrogel contraction and stiffness showed no significant difference between LBP pre-treatment and control groups. Fibroblasts pretreated with LBP as well had reduced angiogenic factors expression and suppression of undesired proliferation (p < 0.05). CONCLUSION Our results showed that LBP reduced both pro-fibrotic proteins and pro-inflammatory cytokines on corneal injury in vitro. We suggest that LBP, as a natural Traditional Chinese Medicine, may potentially be a novel topical pre-treatment option prior to corneal refractive surgeries with an improved prognosis.
Collapse
Affiliation(s)
- Ho Lam Wong
- Department of Ophthalmology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region
| | - Lap Tak Hung
- Department of Mechanical Engineering, Faculty of Engineering, The University of Hong Kong, Hong Kong Special Administrative Region
| | - Sum Sum Kwok
- Department of Ophthalmology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region
| | - Yashan Bu
- Department of Ophthalmology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region
| | - Yuan Lin
- Department of Mechanical Engineering, Faculty of Engineering, The University of Hong Kong, Hong Kong Special Administrative Region
| | - Ho Cheung Shum
- Department of Mechanical Engineering, Faculty of Engineering, The University of Hong Kong, Hong Kong Special Administrative Region
| | - Hua Wang
- Eye Center of Xiangya Hospital, Central South University, China; Hunan Key Laboratory of Ophthalmology, China
| | - Amy Cheuk Yin Lo
- Department of Ophthalmology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region
| | - Gary Hin Fai Yam
- Department of Ophthalmology, University of Pittsburgh Medical Centre, USA
| | - Vishal Jhanji
- Department of Ophthalmology, University of Pittsburgh Medical Centre, USA
| | - Kendrick Co Shih
- Department of Ophthalmology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region.
| | - Yau Kei Chan
- Department of Ophthalmology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong Special Administrative Region.
| |
Collapse
|
5
|
García-Posadas L, Diebold Y. Three-Dimensional Human Cell Culture Models to Study the Pathophysiology of the Anterior Eye. Pharmaceutics 2020; 12:E1215. [PMID: 33333869 PMCID: PMC7765302 DOI: 10.3390/pharmaceutics12121215] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 12/11/2020] [Accepted: 12/13/2020] [Indexed: 02/07/2023] Open
Abstract
In recent decades, the establishment of complex three-dimensional (3D) models of tissues has allowed researchers to perform high-quality studies and to not only advance knowledge of the physiology of these tissues but also mimic pathological conditions to test novel therapeutic strategies. The main advantage of 3D models is that they recapitulate the spatial architecture of tissues and thereby provide more physiologically relevant information. The eye is an extremely complex organ that comprises a large variety of highly heterogeneous tissues that are divided into two asymmetrical portions: the anterior and posterior segments. The anterior segment consists of the cornea, conjunctiva, iris, ciliary body, sclera, aqueous humor, and the lens. Different diseases in these tissues can have devastating effects. To study these pathologies and develop new treatments, the use of cell culture models is instrumental, and the better the model, the more relevant the results. Thus, the development of sophisticated 3D models of ocular tissues is a significant challenge with enormous potential. In this review, we present a comprehensive overview of the latest advances in the development of 3D in vitro models of the anterior segment of the eye, with a special focus on those that use human primary cells.
Collapse
Affiliation(s)
- Laura García-Posadas
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, 47011 Valladolid, Spain;
| | - Yolanda Diebold
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, 47011 Valladolid, Spain;
- Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Instituto de Salud Carlos III, 28029 Madrid, Spain
| |
Collapse
|
6
|
Development of In Vitro Corneal Models: Opportunity for Pharmacological Testing. Methods Protoc 2020; 3:mps3040074. [PMID: 33147693 PMCID: PMC7711486 DOI: 10.3390/mps3040074] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2020] [Accepted: 10/30/2020] [Indexed: 12/12/2022] Open
Abstract
The human eye is a specialized organ with a complex anatomy and physiology, because it is characterized by different cell types with specific physiological functions. Given the complexity of the eye, ocular tissues are finely organized and orchestrated. In the last few years, many in vitro models have been developed in order to meet the 3Rs principle (Replacement, Reduction and Refinement) for eye toxicity testing. This procedure is highly necessary to ensure that the risks associated with ophthalmic products meet appropriate safety criteria. In vitro preclinical testing is now a well-established practice of significant importance for evaluating the efficacy and safety of cosmetic, pharmaceutical, and nutraceutical products. Along with in vitro testing, also computational procedures, herein described, for evaluating the pharmacological profile of potential ocular drug candidates including their toxicity, are in rapid expansion. In this review, the ocular cell types and functionality are described, providing an overview about the scientific challenge for the development of three-dimensional (3D) in vitro models.
Collapse
|
7
|
Peng Z, Zhou L, Wong JKW, Chan YK. Eye-on-a-chip (EOC) models and their role in the future of ophthalmic drug discovery. EXPERT REVIEW OF OPHTHALMOLOGY 2020. [DOI: 10.1080/17469899.2020.1788388] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Affiliation(s)
- Zhiting Peng
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, P.R.China
| | - Liangyu Zhou
- Department of Ophthalmology, Li Ka Shing Faculty of Medicine, University of Hong Kong, Pokfulam, Hong Kong SAR
| | - Jasper Ka Wai Wong
- Department of Ophthalmology, Li Ka Shing Faculty of Medicine, University of Hong Kong, Pokfulam, Hong Kong SAR
| | - Yau Kei Chan
- Department of Ophthalmology, Li Ka Shing Faculty of Medicine, University of Hong Kong, Pokfulam, Hong Kong SAR
| |
Collapse
|
8
|
Jairam RK, Mallurwar SR, Gabani BB, Zakkula A, Kiran V, Dittakavi S, Sulochana SP, Mohd Z, Srinivas NR, Mullangi R. Uptake and pharmacokinetics of cefuroxime in rabbits after intravitreal, intracameral, and topical dosing: relevance to human ocular injection of cefuroxime. Xenobiotica 2019; 50:339-345. [PMID: 31144563 DOI: 10.1080/00498254.2019.1624872] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Cefuroxime is one of the widely used antibiotics. The objective of this study was to determine pharmacokinetics and disposition in various ocular tissues following topical (TOP), intracameral (IC) and intravitreal (IVT) administration of cefuroxime to rabbits.Following TOP, IC and IVT dosing plasma and various ocular tissues (aqueous humor (AH), vitreous humor (VH), conjunctiva, trabecular mesh (TM), lens and retina-choroid (RC)) were collected and analyzed to understand the disposition of cefuroxime. Postintravenous administration plasma samples were collected to determine the systemic pharmacokinetics.Post-TOP dosing cefuroxime concentrations were observed only in conjunctiva up to 48 h. IC administration showed cefuroxime concentrations in AH up to 8 h; in conjunctiva, TM and plasma, the concentration lasted up to 4 h and in RC and VH till 1 h. IVT administration of cefuroxime showed concentrations in all ocular tissues (up to 8 h) and lasted up to 48 h except in conjunctiva and RC.There was evidence that the mechanism(s) of cefuroxime entry into the eye by via IVT, IC and TOP routes is clearly different. The present ocular tissue data may aid clinicians for considering appropriate choice in the treatment of post-operative ocular complications due to bacterial infections including endophthalmitis.
Collapse
Affiliation(s)
- Ravi Kumar Jairam
- Drug Metabolism and Pharmacokinetics, Industrial Suburb, Yeshwanthpur, Bangalore, India
| | - Sadanand R Mallurwar
- Drug Metabolism and Pharmacokinetics, Industrial Suburb, Yeshwanthpur, Bangalore, India
| | - Bhavesh B Gabani
- Drug Metabolism and Pharmacokinetics, Industrial Suburb, Yeshwanthpur, Bangalore, India
| | - Ashok Zakkula
- Drug Metabolism and Pharmacokinetics, Industrial Suburb, Yeshwanthpur, Bangalore, India
| | - Vinay Kiran
- Drug Metabolism and Pharmacokinetics, Industrial Suburb, Yeshwanthpur, Bangalore, India
| | - Sreekanth Dittakavi
- Drug Metabolism and Pharmacokinetics, Industrial Suburb, Yeshwanthpur, Bangalore, India
| | - Suresh P Sulochana
- Drug Metabolism and Pharmacokinetics, Industrial Suburb, Yeshwanthpur, Bangalore, India
| | - Zainuddin Mohd
- Drug Metabolism and Pharmacokinetics, Industrial Suburb, Yeshwanthpur, Bangalore, India
| | | | - Ramesh Mullangi
- Drug Metabolism and Pharmacokinetics, Industrial Suburb, Yeshwanthpur, Bangalore, India
| |
Collapse
|
9
|
Alvarez-Lorenzo C, Anguiano-Igea S, Varela-García A, Vivero-Lopez M, Concheiro A. Bioinspired hydrogels for drug-eluting contact lenses. Acta Biomater 2019; 84:49-62. [PMID: 30448434 DOI: 10.1016/j.actbio.2018.11.020] [Citation(s) in RCA: 64] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Revised: 10/29/2018] [Accepted: 11/14/2018] [Indexed: 12/14/2022]
Abstract
Efficient ocular drug delivery that can overcome the challenges of topical application has been largely pursued. Contact lenses (CLs) may act as light-transparent cornea/sclera bandages for prolonged drug release towards the post-lens tear fluid, if their composition and inner architecture are fitted to the features of the drug molecules. In this review, first the foundations and advantages of using CLs as ocular drug depots are revisited. Then, pros and cons of common strategies to prepare drug-loaded CLs are analyzed on the basis of recent examples, and finally the main section focuses on bioinspired strategies that can overcome some limitations of current designs. Most bioinspired strategies resemble a reverse engineering process to create artificial receptors for the drug inside the CL network by mimicking the human natural binding site of the drug. Related bioinspired strategies are being also tested for designing CLs that elute comfort ingredients mimicking the blinking-associated renewal of eye mucins. Other bioinspired approaches exploit the natural eye variables as stimuli to trigger drug release or take benefit of bio-glues to specifically bind active components to the CL surface. Overall, biomimicking approaches are being revealed as valuable tools to fit the amounts loaded and the release profiles to the therapeutic demands of each pathology. STATEMENT OF SIGNIFICANCE: Biomimetic and bioinspired strategies are remarkable tools for the optimization of drug delivery systems. Translation of the knowledge about how drugs interact with the natural pharmacological receptor and about components and dynamics of anterior eye segment may shed light on the design criteria for obtaining efficient drug-eluting CLs. Current strategies for endowing CLs with controlled drug release performance still require optimization regarding amount loaded, drug retained in the CL structure during storage, regulation of drug release once applied onto the eye, and maintenance of CL physical properties. All these limitations may be addressed through a variety of recently growing bioinspired approaches, which are expected to pave the way of medicated CLs towards the clinics.
Collapse
Affiliation(s)
- Carmen Alvarez-Lorenzo
- Departamento de Farmacología, Farmacia y Tecnología Farmacéutica, R+D Pharma Group (GI-1645), Facultad de Farmacia and Health Research Institute of Santiago de Compostela (IDIS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain.
| | - Soledad Anguiano-Igea
- HGBeyond Materials Science S.L, Edificio Emprendia, Campus Vida s/n, 15782 Santiago de Compostela, Spain
| | - Angela Varela-García
- Departamento de Farmacología, Farmacia y Tecnología Farmacéutica, R+D Pharma Group (GI-1645), Facultad de Farmacia and Health Research Institute of Santiago de Compostela (IDIS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain; HGBeyond Materials Science S.L, Edificio Emprendia, Campus Vida s/n, 15782 Santiago de Compostela, Spain
| | - María Vivero-Lopez
- Departamento de Farmacología, Farmacia y Tecnología Farmacéutica, R+D Pharma Group (GI-1645), Facultad de Farmacia and Health Research Institute of Santiago de Compostela (IDIS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain
| | - Angel Concheiro
- Departamento de Farmacología, Farmacia y Tecnología Farmacéutica, R+D Pharma Group (GI-1645), Facultad de Farmacia and Health Research Institute of Santiago de Compostela (IDIS), Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain
| |
Collapse
|
10
|
Haderspeck JC, Chuchuy J, Kustermann S, Liebau S, Loskill P. Organ-on-a-chip technologies that can transform ophthalmic drug discovery and disease modeling. Expert Opin Drug Discov 2018; 14:47-57. [DOI: 10.1080/17460441.2019.1551873] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Jasmin C. Haderspeck
- Institute of Neuroanatomy & Developmental Biology (INDB), Eberhard Karls University Tübingen, Tübingen, Germany
| | - Johanna Chuchuy
- Department of Women’s Health, Research Institute for Women’s Health, Eberhard Karls University Tübingen, Tübingen, Germany
- Fraunhofer Institute for Interfacial Engineering and Biotechnology IGB, Stuttgart, Germany
| | - Stefan Kustermann
- Pharmaceutical Sciences, Roche Pharma Research and Early Development, Roche Innovation Center Basel, F. Hoffmann-La Roche Ltd., Basel, Switzerland
| | - Stefan Liebau
- Institute of Neuroanatomy & Developmental Biology (INDB), Eberhard Karls University Tübingen, Tübingen, Germany
| | - Peter Loskill
- Department of Women’s Health, Research Institute for Women’s Health, Eberhard Karls University Tübingen, Tübingen, Germany
- Fraunhofer Institute for Interfacial Engineering and Biotechnology IGB, Stuttgart, Germany
| |
Collapse
|
11
|
Mandenius CF. Conceptual Design of Micro-Bioreactors and Organ-on-Chips for Studies of Cell Cultures. Bioengineering (Basel) 2018; 5:E56. [PMID: 30029542 PMCID: PMC6164921 DOI: 10.3390/bioengineering5030056] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2018] [Revised: 07/13/2018] [Accepted: 07/14/2018] [Indexed: 01/19/2023] Open
Abstract
Engineering design of microbioreactors (MBRs) and organ-on-chip (OoC) devices can take advantage of established design science theory, in which systematic evaluation of functional concepts and user requirements are analyzed. This is commonly referred to as a conceptual design. This review article compares how common conceptual design principles are applicable to MBR and OoC devices. The complexity of this design, which is exemplified by MBRs for scaled-down cell cultures in bioprocess development and drug testing in OoCs for heart and eye, is discussed and compared with previous design solutions of MBRs and OoCs, from the perspective of how similarities in understanding design from functionality and user purpose perspectives can more efficiently be exploited. The review can serve as a guideline and help the future design of MBR and OoC devices for cell culture studies.
Collapse
|
12
|
Bennet D, Estlack Z, Reid T, Kim J. A microengineered human corneal epithelium-on-a-chip for eye drops mass transport evaluation. LAB ON A CHIP 2018; 18:1539-1551. [PMID: 29736535 DOI: 10.1039/c8lc00158h] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Animals are commonly used for pharmacokinetic studies which are the most frequent events tested during ocular drug development and preclinical evaluation. Inaccuracy, cost, and ethical criticism in these tests have created a need to construct an in vitro model for studying corneal constraints. In this work, a porous membrane embedded microfluidic platform is fabricated that separates a chip into an apical and basal side. After functionalizing the membrane surface with fibronectin, the membrane's mechanical and surface properties are measured to ensure correct modeling of in vivo characteristics. Immortalized human corneal epithelial cells are cultured on the membrane to create a microengineered corneal epithelium-on-a-chip (cornea chip) that is validated with experiments designed to test the barrier properties of the human corneal epithelium construct using model drugs. A pulsatile flow model is used that closely mimics the ocular precorneal constraints and is reasonable for permeability analysis that models in vivo conditions. This model can be used for preclinical evaluations of potential therapeutic drugs and to mimic the environment of the human cornea.
Collapse
Affiliation(s)
- Devasier Bennet
- Department of Mechanical Engineering, Texas Tech University, Lubbock, Texas 79409, USA.
| | | | | | | |
Collapse
|