1
|
Haak A, Lesslich HM, Dietzel ID. Visualization of the membrane surface and cytoskeleton of oligodendrocyte progenitor cell growth cones using a combination of scanning ion conductance and four times expansion microscopy. Biol Chem 2024; 405:31-41. [PMID: 37950644 DOI: 10.1515/hsz-2023-0217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Accepted: 10/17/2023] [Indexed: 11/13/2023]
Abstract
Growth cones of oligodendrocyte progenitor cells (OPCs) are challenging to investigate with conventional light microscopy due to their small size. Especially substructures such as filopodia, lamellipodia and their underlying cytoskeleton are difficult to resolve with diffraction limited microscopy. Light microscopy techniques, which surpass the diffraction limit such as stimulated emission depletion microscopy, often require expensive setups and specially trained personnel rendering them inaccessible to smaller research groups. Lately, the invention of expansion microscopy (ExM) has enabled super-resolution imaging with any light microscope without the need for additional equipment. Apart from the necessary resolution, investigating OPC growth cones comes with another challenge: Imaging the topography of membranes, especially label- and contact-free, is only possible with very few microscopy techniques one of them being scanning ion conductance microscopy (SICM). We here present a new imaging workflow combining SICM and ExM, which enables the visualization of OPC growth cone nanostructures. We correlated SICM recordings and ExM images of OPC growth cones captured with a conventional widefield microscope. This enabled the visualization of the growth cones' membrane topography as well as their underlying actin and tubulin cytoskeleton.
Collapse
Affiliation(s)
- Annika Haak
- Nanoscopy, RUBION, Ruhr-Universität Bochum, Universitätsstraße 150, D-44801 Bochum, Germany
| | - Heiko M Lesslich
- Nanoscopy, RUBION, Ruhr-Universität Bochum, Universitätsstraße 150, D-44801 Bochum, Germany
| | - Irmgard D Dietzel
- Department of Biochemistry II, Electrobiochemistry of Neural Cells, Ruhr-Universität Bochum, D-44801 Bochum, Germany
| |
Collapse
|
2
|
Chen F, He J, Manandhar P, Yang Y, Liu P, Gu N. Gauging surface charge distribution of live cell membrane by ionic current change using scanning ion conductance microscopy. NANOSCALE 2021; 13:19973-19984. [PMID: 34825684 DOI: 10.1039/d1nr05230f] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The distribution of surface charge and potential of cell membrane plays an indispensable role in cellular activities. However, probing surface charge of live cells under physiological conditions, until recently, remains an arduous challenge owing to the lack of effective methods. Scanning ion conductance microscopy (SICM) is an emerging imaging technique for imaging a live cell membrane in its native state. Here, we introduce a simple SICM based imaging technique to effectively map the surface charge contrast distribution of soft substrates including cell membranes by utilizing the higher surface charge sensitivity of the ionic current when the nanopipette tip is close to the substrate with a relatively high current change. This technique was assessed on charged model substrates made of polydimethylsiloxane, and the surface charge sensitivity of ionic current change was supported by finite element method simulations. With this method, we can distinguish the surface charge difference between the cell membrane and the supporting collagen matrix. We also observed the surface charge change induced by the small membrane damage after 1% dimethyl sulfoxide (DMSO) treatment. This new SICM technique provides opportunities to study interfacial and cell membrane processes with high spatial resolution.
Collapse
Affiliation(s)
- Feng Chen
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, People's Republic of China
- Physics Department, Biomolecular Science Institute, Florida International University, Miami, FL 33199, USA.
| | - Jin He
- Physics Department, Biomolecular Science Institute, Florida International University, Miami, FL 33199, USA.
| | - Prakash Manandhar
- Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199, USA
| | - Yizi Yang
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, People's Republic of China
| | - Peidang Liu
- Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210009, China.
| | - Ning Gu
- School of Biomedical Engineering and Informatics, Nanjing Medical University, Nanjing 211166, People's Republic of China
- Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210009, China.
| |
Collapse
|
3
|
Abstract
Scanning ion conductance microscopy (SICM) has emerged as a versatile tool for studies of interfaces in biology and materials science with notable utility in biophysical and electrochemical measurements. The heart of the SICM is a nanometer-scale electrolyte filled glass pipette that serves as a scanning probe. In the initial conception, manipulations of ion currents through the tip of the pipette and appropriate positioning hardware provided a route to recording micro- and nanoscopic mapping of the topography of surfaces. Subsequent advances in instrumentation, probe design, and methods significantly increased opportunities for SICM beyond recording topography. Hybridization of SICM with coincident characterization techniques such as optical microscopy and faradaic electrodes have brought SICM to the forefront as a tool for nanoscale chemical measurement for a wide range of applications. Modern approaches to SICM realize an important tool in analytical, bioanalytical, biophysical, and materials measurements, where significant opportunities remain for further exploration. In this review, we chronicle the development of SICM from the perspective of both the development of instrumentation and methods and the breadth of measurements performed.
Collapse
Affiliation(s)
- Cheng Zhu
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Kaixiang Huang
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Natasha P Siepser
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| | - Lane A Baker
- Department of Chemistry, Indiana University, 800 E. Kirkwood Avenue, Bloomington, Indiana 47405, United States
| |
Collapse
|
4
|
Rose KA, Lee D, Composto RJ. pH-Mediated nanoparticle dynamics in hydrogel nanocomposites. SOFT MATTER 2021; 17:2765-2774. [PMID: 33538749 DOI: 10.1039/d0sm02213f] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The effect of static silica particles on the dynamics of quantum dot (QD) nanoparticles grafted with a poly(ethylene glycol) (PEG) brush in hydrogel nanocomposites is investigated using single particle tracking (SPT). At a low volume fraction of homogeneously dispersed silica (Φ = 0.005), two distinct populations of PEG-QDs are observed, localized and mobile, whereas almost all PEG-QDs are mobile in neat hydrogel (Φ = 0.0). Increasing the silica particle concentration (Φ = 0.01, 0.1) results in an apparent change in the network structure, confounding the impact of silica on PEG-QD dynamics. The localized behavior of PEG-QDs is attributed to pH-mediated attraction between the PEG brush on the probe and surface silanol groups of silica. Using quartz crystal microbalance with dissipation (QCM-D), the extent of this interaction is investigated as a function of pH. At pH 5.8, the PEG brush on the probe can hydrogen bond with the silanol groups on silica, leading to adsorption of PEG-QDs. In contrast, at pH 9.2, silanol groups are deprotonated and PEG-QD is unable to hydrogen bond with silica leading to negligible adsorption. To test the effect of pH, PEG-QD dynamics are further investigated in hydrogel nanocomposites at Φ = 0.005. SPT agrees with the QCM-D results; at pH 5.8, PEG-QDs are localized whereas at pH 9.2 the PEG-QDs are mobile. This study provides insight into controlling probe transport through hydrogel nanocomposites using pH-mediated interactions, with implications for tuning transport of nanoparticles underlying drug delivery and nanofiltration.
Collapse
Affiliation(s)
- Katie A Rose
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA.
| | - Daeyeon Lee
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA.
| | - Russell J Composto
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA. and Department of Materials Science and Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA and Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104, USA
| |
Collapse
|
5
|
Zhuang J, Yan H, Zheng Q, Wang T, Liao X. Study on a Rapid Imaging Method for Scanning Ion Conductance Microscopy Using a Double-Barreled Theta Pipette. Anal Chem 2020; 92:15789-15798. [PMID: 33283496 DOI: 10.1021/acs.analchem.0c02840] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Scanning ion conductance microscopy (SICM) is a new noncontact, high-resolution scanning probe microscopy technique, which has become increasingly popular in recent years. The hopping mode-currently the most widely used scanning mode-can be used for imaging samples with complicated surface topographies. However, its slow scanning rate seriously restricts its broader application. This paper proposes a fast imaging control mode using a double-barreled theta pipette as the probe, which effectively increases the imaging rate. In this mode, sample surface height information is obtained when the double-barreled theta pipette approaches the sample in a two-step downward process. The ion current sum of two barrels and ion current of one barrel are used as feedback signals to approach the sample until the feedback signals decrease to the set threshold, respectively, thereby obtaining the height of the imaging point. First, this work used COMSOL to establish an SICM model and perform simulation analysis. The simulation results verified the proposed method's feasibility. Second, a scanning time mathematical model was established. The results revealed that the new method is superior to the traditional method in terms of imaging rate. Finally, experiments were performed on poly(dimethylsiloxane) (PDMS) samples using the two imaging modes described above. The results demonstrated that the new scanning mode could significantly improve the imaging rate of SICM without a loss in imaging quality and stability.
Collapse
Affiliation(s)
- Jian Zhuang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China.,School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Heng Yan
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China.,School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Qiangqiang Zheng
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China.,School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Tingkai Wang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China.,School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Xiaobo Liao
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China.,School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, China.,School of Manufacturing Science and Engineering, Key Laboratory of Testing Technology for Manufacturing Process, Ministry of Education, Southwest University of Science and Technology, Mianyang 621010, China
| |
Collapse
|
6
|
Gesper A, Wennmalm S, Hagemann P, Eriksson SG, Happel P, Parmryd I. Variations in Plasma Membrane Topography Can Explain Heterogenous Diffusion Coefficients Obtained by Fluorescence Correlation Spectroscopy. Front Cell Dev Biol 2020; 8:767. [PMID: 32903922 PMCID: PMC7443568 DOI: 10.3389/fcell.2020.00767] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Accepted: 07/21/2020] [Indexed: 01/18/2023] Open
Abstract
Fluorescence correlation spectroscopy (FCS) is frequently used to study diffusion in cell membranes, primarily the plasma membrane. The diffusion coefficients reported in the plasma membrane of the same cell type and even within single cells typically display a large spread. We have investigated whether this spread can be explained by variations in membrane topography throughout the cell surface, that changes the amount of membrane in the FCS focal volume at different locations. Using FCS, we found that diffusion of the membrane dye DiI in the apical plasma membrane was consistently faster above the nucleus than above the cytoplasm. Using live cell scanning ion conductance microscopy (SICM) to obtain a topography map of the cell surface, we demonstrate that cell surface roughness is unevenly distributed with the plasma membrane above the nucleus being the smoothest, suggesting that the difference in diffusion observed in FCS is related to membrane topography. FCS modeled on simulated diffusion in cell surfaces obtained by SICM was consistent with the FCS data from live cells and demonstrated that topography variations can cause the appearance of anomalous diffusion in FCS measurements. Furthermore, we found that variations in the amount of the membrane marker DiD, a proxy for the membrane, but not the transmembrane protein TCRζ or the lipid-anchored protein Lck, in the FCS focal volume were related to variations in diffusion times at different positions in the plasma membrane. This relationship was seen at different positions both at the apical cell and basal cell sides. We conclude that it is crucial to consider variations in topography in the interpretation of FCS results from membranes.
Collapse
Affiliation(s)
| | - Stefan Wennmalm
- SciLifeLab, Royal Institute of Technology, Stockholm, Sweden
| | | | | | | | - Ingela Parmryd
- Institute of Biomedicine, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
7
|
Zhuang J, Cheng L, Liao X, Zia AA, Wang Z. A fuzzy control for high-speed and low-overshoot hopping probe ion conductance microscopy. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:033703. [PMID: 32259936 DOI: 10.1063/1.5114642] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Accepted: 02/07/2020] [Indexed: 06/11/2023]
Abstract
At present, hopping probe ion conductance microscopy (HPICM) is the most capable ion conductance microscopy for imaging complex surface topography. However, the HPICM controller usually does not begin to stop the pipette sample approach until the ion current reaches a threshold, which results in short deceleration distances. Furthermore, closed-loop piezo actuation usually increases the response time. These problems tend to increase the ion current overshoot and affect imaging speed and quality. A fuzzy control system was developed to solve these problems via ion current deviation and deviation rate. This lengthens the deceleration distance to enable a high-speed approach toward the sample and smooth deceleration. Open-loop control of the piezo actuator is also used to increase sensitivity. To compensate for the nonlinearity of the actuator, a multi-section fuzzy logic strategy was used to maintain performance in all sections. Glass and poly(dimethylsiloxane) samples were used to demonstrate greater imaging speed and stability of the fuzzy controller relative to those of conventional controllers.
Collapse
Affiliation(s)
- Jian Zhuang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China
| | - Lei Cheng
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China
| | - Xiaobo Liao
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China
| | - Ali Akmal Zia
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China
| | - Zhiwu Wang
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, China
| |
Collapse
|
8
|
Simeonov S, Schäffer TE. High-speed scanning ion conductance microscopy for sub-second topography imaging of live cells. NANOSCALE 2019; 11:8579-8587. [PMID: 30994121 DOI: 10.1039/c8nr10162k] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Scanning ion conductance microscopy (SICM) is an emerging tool for non-invasive and high-resolution topography imaging of live cells. However, the imaging speed of conventional SICM setups is slow, requiring several seconds or even minutes per image, thereby making it difficult to study cellular dynamics. Here, we describe a high-speed SICM (HS-SICM) setup for topography imaging in the hopping mode with a pixel rate of 11.0 kHz, which is 15 times faster than what was reported before. In combination with a "turn step" procedure for rapid pipette retraction, we image the ultra-fast morphodynamics of live human platelets, A6 cells, and U2OS cells at a rate as fast as 0.6 s per frame. The results show that HS-SICM provides a useful platform for investigating the dynamics of cell morphology on a sub-second timescale.
Collapse
Affiliation(s)
- Stefan Simeonov
- Institute of Applied Physics, University of Tübingen, Auf der Morgenstelle 10, 72076 Tübingen, Germany.
| | | |
Collapse
|
9
|
Bentley CL, Edmondson J, Meloni GN, Perry D, Shkirskiy V, Unwin PR. Nanoscale Electrochemical Mapping. Anal Chem 2018; 91:84-108. [PMID: 30500157 DOI: 10.1021/acs.analchem.8b05235] [Citation(s) in RCA: 94] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
10
|
Hagemann P, Gesper A, Happel P. Correlative Stimulated Emission Depletion and Scanning Ion Conductance Microscopy. ACS NANO 2018; 12:5807-5815. [PMID: 29791140 DOI: 10.1021/acsnano.8b01731] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Correlation microscopy combining fluorescence and scanning probe or electron microscopy is limited to fixed samples due to the sample preparation and nonphysiological imaging conditions required by most probe or electron microscopy techniques. Among the few scanning probe techniques that allow imaging of living cells under physiological conditions, scanning ion conductance microscopy (SICM) has been shown to be the technique that minimizes the impact on the investigated sample. However, combinations of SICM and fluorescence microscopy suffered from the mismatch in resolution due to the limited resolution of conventional light microscopy. In the last years, the diffraction limit of light microscopy has been circumvented by various techniques, one of which is stimulated emission depletion (STED) microscopy. Here, we aimed at demonstrating the combination of STED and SICM. We show that both methods allow recording a living cellular specimen and provide a SICM and STED image of the same sample, which allowed us to correlate the membrane surface topography and the distribution of the cytoskeletal protein actin. Our proof-of-concept study exemplifies the benefit of correlating SICM with a subdiffraction fluorescence method and might form the basis for the development of a combined instrument that would allow the simultaneous recording of subdiffraction fluorescence and topography information.
Collapse
Affiliation(s)
- Philipp Hagemann
- Nanoscopy Group, RUBION , Ruhr-Universität Bochum , Universitätsstraße 150 , D-44801 , Bochum , Germany
| | - Astrid Gesper
- Nanoscopy Group, RUBION , Ruhr-Universität Bochum , Universitätsstraße 150 , D-44801 , Bochum , Germany
| | - Patrick Happel
- Nanoscopy Group, RUBION , Ruhr-Universität Bochum , Universitätsstraße 150 , D-44801 , Bochum , Germany
| |
Collapse
|
11
|
Zhou Y, Saito M, Miyamoto T, Novak P, Shevchuk AI, Korchev YE, Fukuma T, Takahashi Y. Nanoscale Imaging of Primary Cilia with Scanning Ion Conductance Microscopy. Anal Chem 2018; 90:2891-2895. [DOI: 10.1021/acs.analchem.7b05112] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Yuanshu Zhou
- Division
of Electrical Engineering and Computer Science, Kanazawa University, Kanazawa 920-1192, Japan
| | - Masaki Saito
- Department
of Molecular Pharmacology, Tohoku University Graduate School of Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai 980-8575, Japan
| | - Takafumi Miyamoto
- Division
of Electrical Engineering and Computer Science, Kanazawa University, Kanazawa 920-1192, Japan
| | - Pavel Novak
- School
of Engineering and Materials Science, Queen Mary, University of London, Mile End Road, London E1 4NS, United Kingdom
| | - Andrew I Shevchuk
- Department
of Medicine, Imperial College London, London W12 0NN, United Kingdom
| | - Yuri E Korchev
- Department
of Medicine, Imperial College London, London W12 0NN, United Kingdom
| | - Takeshi Fukuma
- Division
of Electrical Engineering and Computer Science, Kanazawa University, Kanazawa 920-1192, Japan
- WPI
Nano Life Science Institute (WPI-NanoLSI), Kanazawa University, Kanazawa 920-1192, Japan
| | - Yasufumi Takahashi
- Division
of Electrical Engineering and Computer Science, Kanazawa University, Kanazawa 920-1192, Japan
- Precursory
Research for Embryonic Science and Technology (PRESTO), Japan Science and Technology Agency (JST), Saitama 332-0012, Japan
| |
Collapse
|