1
|
Silva Elipe MV, Ndukwe IE, Murray JI. Cryogen-free 400-MHz nuclear magnetic resonance spectrometer as a versatile tool for pharmaceutical process analytical technology. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2024; 62:512-534. [PMID: 38369696 DOI: 10.1002/mrc.5434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 01/15/2024] [Accepted: 01/16/2024] [Indexed: 02/20/2024]
Abstract
The discovery of new ceramic materials containing Ba-La-Cu oxides in 1986 that exhibited superconducting properties at high temperatures in the range of 35 K or higher, recognized with the Nobel Prize in Physics in 1987, opened a new world of opportunities for nuclear magnetic resonance (NMRs) and magnetic resonance imaging (MRIs) to move away from liquid cryogens. This discovery expands the application of high temperature superconducting (HTS) materials to fields beyond the chemical and medical industries, including electrical power grids, energy, and aerospace. The prototype 400-MHz cryofree HTS NMR spectrometer installed at Amgen's chemistry laboratory has been vital for a variety of applications such as structure analysis, reaction monitoring, and CASE-3D studies with RDCs. The spectrometer has been integrated with Amgen's chemistry and analytical workflows, providing pipeline project support in tandem with other Kinetic Analysis Platform technologies. The 400-MHz cryofree HTS NMR spectrometer, as the name implies, does not require liquid cryogens refills and has smaller footprint that facilitates installation into a chemistry laboratory fume hood, sharing the hood with a process chemistry reactor. Our evaluation of its performance for structural analysis with CASE-3D protocol and for reaction monitoring of Amgen's pipeline chemistry was successful. We envision that the HTS magnets would become part of the standard NMR and MRI spectrometers in the future. We believe that while the technology is being developed, there is room for all magnet options, including HTS, low temperature superconducting (LTS) magnets, and low field benchtop NMRs with permanent magnets, where utilization will be dependent on application type and costs.
Collapse
Affiliation(s)
| | - Ikenna Edward Ndukwe
- Department of Attribute Sciences, Process Development, Amgen Inc., Thousand Oaks, California, USA
| | - James I Murray
- Pivotal and Commercial Drug Substance Technologies, Process Development, Amgen Inc., Thousand Oaks, California, USA
| |
Collapse
|
2
|
Deckers C, Rehm TH. In situ Diazonium Salt Formation and Photochemical Aryl-Aryl Coupling in Continuous Flow Monitored by Inline NMR Spectroscopy. Chemistry 2024; 30:e202303692. [PMID: 38462439 DOI: 10.1002/chem.202303692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Revised: 03/09/2024] [Accepted: 03/10/2024] [Indexed: 03/12/2024]
Abstract
A novel class of diazonium salts is introduced for the photochemical aryl-aryl coupling to produce (substituted) biphenyls. As common diazonium tetrafluoroborate salts fail, soluble and safe aryl diazonium trifluoroacetates are applied. In this mild synthesis route no catalysts are required to generate an aryl-radical by irradiation with UV-A light (365 nm). This reactive species undergoes direct C-H arylation at an arene, forming the product in reasonable reaction times. With the implementation of a continuous flow setup in a capillary photoreactor 13 different biphenyl derivatives are successfully synthesized. By integrating an inline 19F-NMR benchtop spectrometer, samples are reliably quantified as the fluorine-substituents act as a probe. Here, real-time NMR spectroscopy is a perfect tool to monitor the continuously operated system, which produces fine chemicals of industrial relevance even in a multigram scale.
Collapse
Affiliation(s)
- Christoph Deckers
- Division Chemistry, Sustainable Chemical Syntheses Group, Fraunhofer Institute for Microengineering and Microsystems IMM, Carl-Zeiss-Strasse 18-20, 55129, Mainz, Germany
- Johannes Gutenberg University Mainz, Department of Chemistry, Duesbergweg 10-14, 55128, Mainz, Germany
| | - Thomas H Rehm
- Division Chemistry, Sustainable Chemical Syntheses Group, Fraunhofer Institute for Microengineering and Microsystems IMM, Carl-Zeiss-Strasse 18-20, 55129, Mainz, Germany
| |
Collapse
|
3
|
Robinson AD, Hill-Casey F, Duckett SB, Halse ME. Quantitative reaction monitoring using parahydrogen-enhanced benchtop NMR spectroscopy. Phys Chem Chem Phys 2024; 26:14317-14328. [PMID: 38695736 DOI: 10.1039/d3cp06221j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2024]
Abstract
The parahydrogen-induced polarisation (PHIP) NMR signal enhancement technique is used to study H2 addition to Vaska's complex (trans-[IrCl(CO)(PPh3)2]) with both standard high-field (9.4 T) NMR and benchtop (1 T) NMR detection. Accurate and repeatable rate constants of (0.84 ± 0.03) dm3 mol-1 s-1 and (0.89 ± 0.03) dm3 mol-1 s-1 were obtained for this model system using standard high-field and benchtop NMR, respectively. The high-field NMR approach is shown to be susceptible to systematic errors associated with interference from non-hyperpolarised signals, which can be overcome through a multiple-quantum filtered acquisition scheme. This challenge is avoided when using benchtop NMR detection because the non-hyperpolarised signals are much weaker due to the lower magnetic field, enabling the use of a simpler and more efficient single RF pulse detection scheme. Method validation against several experimental parameters (NMR relaxation, %pH2 enrichment and temperature) demonstrates the robustness of the benchtop NMR approach but also highlights the need for sample temperature control throughout reaction monitoring. A simple temperature equilibration protocol, coupled with use of an insulated sample holder while manipulating the sample outside the spectrometer, is found to provide sufficient temperature stabilisation to ensure that accurate and repeatable rate constants are obtained. Finally, the benchtop NMR reaction monitoring protocol is applied to the analysis of a complex mixture, where multiple reaction products form simultaneously. H2 addition to a mixture of three Vaska's complex derivatives was monitored, revealing the presence of competitive reaction pathways within the mixture.
Collapse
|
4
|
Maschmeyer T, Russell DJ, Napolitano JG, Hein JE. Reaction monitoring via benchtop nuclear magnetic resonance spectroscopy: A practical comparison of on-line stopped-flow and continuous-flow sampling methods. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2024; 62:310-322. [PMID: 37737536 DOI: 10.1002/mrc.5395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2023] [Revised: 08/28/2023] [Accepted: 08/30/2023] [Indexed: 09/23/2023]
Abstract
The ability for nuclear magnetic resonance (NMR) spectroscopy to provide quantitative, structurally rich information makes this spectroscopic technique an attractive reaction monitoring tool. The practicality of NMR for this type of analysis has only increased in the recent years with the influx of commercially available benchtop NMR instruments and compatible flow systems. In this study, we aim to compare 19F NMR reaction profiles acquired under both on-line continuous-flow and stopped-flow sampling methods, with modern benchtop NMR instrumentation, and two reaction systems: a homogeneous imination reaction and a biphasic activation of a carboxylic acid to acyl fluoride. Reaction trends with higher data density can be acquired with on-line continuous-flow analyses, and this work highlights that representative reaction trends can be acquired without any correction when monitoring resonances with a shorter spin-lattice relaxation time (T1), and with the used flow conditions. On-line stopped-flow analyses resulted in representative reaction trends in all cases, including the monitoring of resonances with a long T1, without the need of any correction factors. The benefit of easier data analysis, however, comes with the cost of time, as the fresh reaction solution must be flowed into the NMR system, halted, and time must be provided for spins to become polarized in the instrument's external magnetic field prior to spectral measurement. Results for one of the reactions were additionally compared with the use of a high-field NMR.
Collapse
Affiliation(s)
- Tristan Maschmeyer
- Department of Chemistry, The University of British Columbia, Vancouver, Canada
- Small Molecule Pharmaceutical Sciences, Genentech Inc., South San Francisco, California, USA
| | - David J Russell
- Small Molecule Pharmaceutical Sciences, Genentech Inc., South San Francisco, California, USA
| | - José G Napolitano
- Small Molecule Pharmaceutical Sciences, Genentech Inc., South San Francisco, California, USA
| | - Jason E Hein
- Department of Chemistry, The University of British Columbia, Vancouver, Canada
- Acceleration Consortium, University of Toronto, Toronto, Canada
- Department of Chemistry, University of Bergen, Bergen, Norway
| |
Collapse
|
5
|
Araneda JF, Leclerc MC, Riegel SD. Benchtop nuclear magnetic resonance performance evaluation according to ASTM E691-22 on a population of instruments: Molar substitution determination in hydroxypropyl betadex as a case study for use in quality control environments. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2024; 62:222-235. [PMID: 37021658 DOI: 10.1002/mrc.5351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 03/15/2023] [Accepted: 03/31/2023] [Indexed: 06/19/2023]
Abstract
The inclusion of quantitative nuclear magnetic resonance (qNMR) spectroscopy in industry has historically been stifled by a lack of accessibility, caused in-part by the large costs of traditional high-field spectrometers, the maintenance required for these, and the expertise necessary to manage and use them. In recent years, the emergence of benchtop NMR technology, an accessible, affordable, and automatable alternative, has led to a more feasible incorporation of NMR into quality control spaces, an area traditionally reserved for other techniques such as gas chromatography and liquid chromatography, which are routinely combined with detection techniques such as mass spectrometry. While these techniques are commonly used in analyzer-type applications using gold standard methods of analysis, wherein an instrument is dedicated to performing specific assays, this remains uncommon for NMR. Herein, we perform a full method verification using benchtop qNMR on a population of benchtop NMR instruments according to the ASTM designation E691-22, a standard used to determine the precision of a test method. To our knowledge, this is the first published example of this type of study for benchtop NMR spectroscopy. For this work, a total of five analysts performed assays on 23 different benchtop NMR instruments for the analysis of hydroxypropyl betadex according to the USP-NF method, and the results are compared using a variety of statistical methods. The results of this work demonstrate that benchtop NMR technology is effective and robust under repeatability and reproducibility conditions and is a powerful tool for these types of routine quality control analyses.
Collapse
Affiliation(s)
- Juan F Araneda
- Nanalysis Corp, 1-4600 5 St NE, Calgary, Alberta, T2E 7C3, Canada
| | | | - Susanne D Riegel
- Nanalysis Corp, 1-4600 5 St NE, Calgary, Alberta, T2E 7C3, Canada
| |
Collapse
|
6
|
Dunlap JH, Ethier JG, Putnam-Neeb AA, Iyer S, Luo SXL, Feng H, Garrido Torres JA, Doyle AG, Swager TM, Vaia RA, Mirau P, Crouse CA, Baldwin LA. Continuous flow synthesis of pyridinium salts accelerated by multi-objective Bayesian optimization with active learning. Chem Sci 2023; 14:8061-8069. [PMID: 37538827 PMCID: PMC10395269 DOI: 10.1039/d3sc01303k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Accepted: 06/19/2023] [Indexed: 08/05/2023] Open
Abstract
We report a human-in-the-loop implementation of the multi-objective experimental design via a Bayesian optimization platform (EDBO+) towards the optimization of butylpyridinium bromide synthesis under continuous flow conditions. The algorithm simultaneously optimized reaction yield and production rate (or space-time yield) and generated a well defined Pareto front. The versatility of EDBO+ was demonstrated by expanding the reaction space mid-campaign by increasing the upper temperature limit. Incorporation of continuous flow techniques enabled improved control over reaction parameters compared to common batch chemistry processes, while providing a route towards future automated syntheses and improved scalability. To that end, we applied the open-source Python module, nmrglue, for semi-automated nuclear magnetic resonance (NMR) spectroscopy analysis, and compared the acquired outputs against those obtained through manual processing methods from spectra collected on both low-field (60 MHz) and high-field (400 MHz) NMR spectrometers. The EDBO+ based model was retrained with these four different datasets and the resulting Pareto front predictions provided insight into the effect of data analysis on model predictions. Finally, quaternization of poly(4-vinylpyridine) with bromobutane illustrated the extension of continuous flow chemistry to synthesize functional materials.
Collapse
Affiliation(s)
- John H Dunlap
- Materials and Manufacturing Directorate, Air Force Research Laboratory Wright-Patterson AFB OH 45433 USA
- UES, Inc. Dayton OH 45431 USA
| | - Jeffrey G Ethier
- Materials and Manufacturing Directorate, Air Force Research Laboratory Wright-Patterson AFB OH 45433 USA
- UES, Inc. Dayton OH 45431 USA
| | - Amelia A Putnam-Neeb
- Materials and Manufacturing Directorate, Air Force Research Laboratory Wright-Patterson AFB OH 45433 USA
- National Research Council Research Associate, Air Force Research Laboratory Wright-Patterson AFB OH 45433 USA
| | - Sanjay Iyer
- Department of Chemistry, Purdue University West Lafayette IN 47907 USA
| | - Shao-Xiong Lennon Luo
- Department of Chemistry, Massachusetts Institute of Technology Cambridge MA 02139 USA
| | - Haosheng Feng
- Department of Chemistry, Massachusetts Institute of Technology Cambridge MA 02139 USA
| | | | - Abigail G Doyle
- Department of Chemistry and Biochemistry, University of California Los Angeles CA 90095 USA
| | - Timothy M Swager
- Department of Chemistry, Massachusetts Institute of Technology Cambridge MA 02139 USA
| | - Richard A Vaia
- Materials and Manufacturing Directorate, Air Force Research Laboratory Wright-Patterson AFB OH 45433 USA
| | - Peter Mirau
- Materials and Manufacturing Directorate, Air Force Research Laboratory Wright-Patterson AFB OH 45433 USA
| | - Christopher A Crouse
- Materials and Manufacturing Directorate, Air Force Research Laboratory Wright-Patterson AFB OH 45433 USA
| | - Luke A Baldwin
- Materials and Manufacturing Directorate, Air Force Research Laboratory Wright-Patterson AFB OH 45433 USA
| |
Collapse
|
7
|
|
8
|
Buglioni L, Raymenants F, Slattery A, Zondag SDA, Noël T. Technological Innovations in Photochemistry for Organic Synthesis: Flow Chemistry, High-Throughput Experimentation, Scale-up, and Photoelectrochemistry. Chem Rev 2022; 122:2752-2906. [PMID: 34375082 PMCID: PMC8796205 DOI: 10.1021/acs.chemrev.1c00332] [Citation(s) in RCA: 208] [Impact Index Per Article: 104.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Indexed: 02/08/2023]
Abstract
Photoinduced chemical transformations have received in recent years a tremendous amount of attention, providing a plethora of opportunities to synthetic organic chemists. However, performing a photochemical transformation can be quite a challenge because of various issues related to the delivery of photons. These challenges have barred the widespread adoption of photochemical steps in the chemical industry. However, in the past decade, several technological innovations have led to more reproducible, selective, and scalable photoinduced reactions. Herein, we provide a comprehensive overview of these exciting technological advances, including flow chemistry, high-throughput experimentation, reactor design and scale-up, and the combination of photo- and electro-chemistry.
Collapse
Affiliation(s)
- Laura Buglioni
- Micro
Flow Chemistry and Synthetic Methodology, Department of Chemical Engineering
and Chemistry, Eindhoven University of Technology, Het Kranenveld, Bldg 14—Helix, 5600 MB, Eindhoven, The Netherlands
- Flow
Chemistry Group, van ’t Hoff Institute for Molecular Sciences
(HIMS), Universiteit van Amsterdam (UvA), Science Park 904, 1098 XH, Amsterdam, The Netherlands
| | - Fabian Raymenants
- Flow
Chemistry Group, van ’t Hoff Institute for Molecular Sciences
(HIMS), Universiteit van Amsterdam (UvA), Science Park 904, 1098 XH, Amsterdam, The Netherlands
| | - Aidan Slattery
- Flow
Chemistry Group, van ’t Hoff Institute for Molecular Sciences
(HIMS), Universiteit van Amsterdam (UvA), Science Park 904, 1098 XH, Amsterdam, The Netherlands
| | - Stefan D. A. Zondag
- Flow
Chemistry Group, van ’t Hoff Institute for Molecular Sciences
(HIMS), Universiteit van Amsterdam (UvA), Science Park 904, 1098 XH, Amsterdam, The Netherlands
| | - Timothy Noël
- Flow
Chemistry Group, van ’t Hoff Institute for Molecular Sciences
(HIMS), Universiteit van Amsterdam (UvA), Science Park 904, 1098 XH, Amsterdam, The Netherlands
| |
Collapse
|
9
|
Maschmeyer T, Yunker LPE, Hein JE. Quantitative and convenient real-time reaction monitoring using stopped-flow benchtop NMR. REACT CHEM ENG 2022. [DOI: 10.1039/d2re00048b] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
We present a stopped-flow benchtop NMR system (composed of commercially available hardware components) that allows for quantitative reaction monitoring to be completed with relative ease, even with experimentally complex reaction systems.
Collapse
Affiliation(s)
- Tristan Maschmeyer
- Department of Chemistry, The University of British Columbia, Vancouver, BC V6T 1Z1, Canada
| | - Lars P. E. Yunker
- Department of Chemistry, The University of British Columbia, Vancouver, BC V6T 1Z1, Canada
| | - Jason E. Hein
- Department of Chemistry, The University of British Columbia, Vancouver, BC V6T 1Z1, Canada
| |
Collapse
|
10
|
Abstract
Benchtop nuclear magnetic resonance (NMR) spectroscopy uses small permanent magnets to generate magnetic fields and therefore offers the advantages of operational simplicity and reasonable cost, presenting a viable alternative to high-field NMR spectroscopy. In particular, the use of benchtop NMR spectroscopy for rapid in-field analysis, e.g., for quality control or forensic science purposes, has attracted considerable attention. As benchtop NMR spectrometers are sufficiently compact to be operated in a fume hood, they can be efficiently used for real-time reaction and process monitoring. This review introduces the recent applications of benchtop NMR spectroscopy in diverse fields, including food science, pharmaceuticals, process and reaction monitoring, metabolomics, and polymer materials.
Collapse
|
11
|
Lau KS, Chin SX, Jaafar SNS, Chia CH. Conversion of glucose into levulinic acid in continuous segmented turbulent flow with enhanced chemical reaction. Tetrahedron Lett 2021. [DOI: 10.1016/j.tetlet.2021.153330] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
12
|
Vasudevan N, Aka EC, Barré E, Wimmer E, Cortés-Borda D, Giraudeau P, Farjon J, Rodriguez-Zubiri M, Felpin FX. Development of a continuous flow synthesis of FGIN-1-27 enabled by in-line 19F NMR analyses and optimization algorithms. REACT CHEM ENG 2021. [DOI: 10.1039/d1re00220a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A continuous flow synthesis of FGIN-1-27 has been developed using enabling technologies such as real-time in-line benchtop 19F NMR analysis and an optimization algorithm.
Collapse
Affiliation(s)
- N. Vasudevan
- Université de Nantes, CNRS, CEISAM UMR 6230, 2 rue de la Houssinière, 44322 Nantes, France
| | - Ehu C. Aka
- Université de Nantes, CNRS, CEISAM UMR 6230, 2 rue de la Houssinière, 44322 Nantes, France
| | - Elvina Barré
- Université de Nantes, CNRS, CEISAM UMR 6230, 2 rue de la Houssinière, 44322 Nantes, France
| | - Eric Wimmer
- Institut de Recherches Servier, 125 Chemin de Ronde, 78290 Croissy sur Seine, France
| | - Daniel Cortés-Borda
- Universidad del Atlántico, Facultad de ciencias básicas, Carrera 30 # 8-49, Puerto Colombia, Atlántico, Colombia
| | - Patrick Giraudeau
- Université de Nantes, CNRS, CEISAM UMR 6230, 2 rue de la Houssinière, 44322 Nantes, France
| | - Jonathan Farjon
- Université de Nantes, CNRS, CEISAM UMR 6230, 2 rue de la Houssinière, 44322 Nantes, France
| | | | - François-Xavier Felpin
- Université de Nantes, CNRS, CEISAM UMR 6230, 2 rue de la Houssinière, 44322 Nantes, France
| |
Collapse
|
13
|
Neyt NC, Riley DL. Application of reactor engineering concepts in continuous flow chemistry: a review. REACT CHEM ENG 2021. [DOI: 10.1039/d1re00004g] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
The adoption of flow technology for the manufacture of chemical entities, and in particular pharmaceuticals, has seen rapid growth over the past two decades with the technology now blurring the lines between chemistry and chemical engineering.
Collapse
Affiliation(s)
- Nicole C. Neyt
- Faculty of Natural and Agricultural Sciences
- Department of Chemistry
- University of Pretoria
- South Africa
| | - Darren L. Riley
- Faculty of Natural and Agricultural Sciences
- Department of Chemistry
- University of Pretoria
- South Africa
| |
Collapse
|
14
|
Howe PWA. Recent developments in the use of fluorine NMR in synthesis and characterisation. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2020; 118-119:1-9. [PMID: 32883447 DOI: 10.1016/j.pnmrs.2020.02.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Revised: 02/14/2020] [Accepted: 02/20/2020] [Indexed: 06/11/2023]
Abstract
A review of developments in fluorine NMR of relevance to synthesis, characterisation and industrial applications of small organic molecules. Developments considered include those in spectrometer technology, computational methods and pulse sequences. The review of 80 references outlines applications in areas of identification, quantitation, mixture analysis, reaction monitoring, environmental studies and fragment-based drug design.
Collapse
Affiliation(s)
- Peter W A Howe
- Syngenta, Jealott's Hill Research Centre, Bracknell, Berkshire RG42 6EY, UK.
| |
Collapse
|
15
|
Fülöp Z, Szemesi P, Bana P, Éles J, Greiner I. Evolution of flow-oriented design strategies in the continuous preparation of pharmaceuticals. REACT CHEM ENG 2020. [DOI: 10.1039/d0re00273a] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
This review focuses on the flow-oriented design (FOD) in the multi-step continuous-flow synthesis of active pharmaceutical ingredients.
Collapse
Affiliation(s)
- Zsolt Fülöp
- Department of Organic Chemistry and Technology
- Budapest University of Technology and Economics
- 1521 Budapest
- Hungary
| | - Péter Szemesi
- Department of Organic Chemistry and Technology
- Budapest University of Technology and Economics
- 1521 Budapest
- Hungary
| | | | | | | |
Collapse
|
16
|
Sagmeister P, Poms J, Williams JD, Kappe CO. Multivariate analysis of inline benchtop NMR data enables rapid optimization of a complex nitration in flow. REACT CHEM ENG 2020. [DOI: 10.1039/d0re00048e] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Multivariate analysis is applied to inline benchtop NMR data for a complex nitration in flow. This rapid quantification enables reaction optimization using advanced techniques in flow, such as design of experiments and dynamic experimentation.
Collapse
Affiliation(s)
- Peter Sagmeister
- Center for Continuous Flow Synthesis and Processing (CCFLOW)
- Research Center Pharmaceutical Engineering (RCPE)
- 8010 Graz
- Austria
- Institute of Chemistry
| | - Johannes Poms
- Research Center Pharmaceutical Engineering (RCPE)
- 8010 Graz
- Austria
| | - Jason D. Williams
- Center for Continuous Flow Synthesis and Processing (CCFLOW)
- Research Center Pharmaceutical Engineering (RCPE)
- 8010 Graz
- Austria
- Institute of Chemistry
| | - C. Oliver Kappe
- Center for Continuous Flow Synthesis and Processing (CCFLOW)
- Research Center Pharmaceutical Engineering (RCPE)
- 8010 Graz
- Austria
- Institute of Chemistry
| |
Collapse
|
17
|
Romero JA, Kazimierczuk K, Gołowicz D. Enhancing benchtop NMR spectroscopy by means of sample shifting. Analyst 2020; 145:7406-7411. [DOI: 10.1039/d0an01556c] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Benchtop NMR sensitivity enhancement by cyclic, mechanical shifting of a sample to preserve high nuclear spin polarization.
Collapse
Affiliation(s)
- Javier A. Romero
- Centre of New Technologies
- University of Warsaw
- 02-097 Warsaw
- Poland
| | | | - Dariusz Gołowicz
- Centre of New Technologies
- University of Warsaw
- 02-097 Warsaw
- Poland
- Faculty of Chemistry
| |
Collapse
|
18
|
Affiliation(s)
- Thomas H. Rehm
- Division Energy & Chemical Technology / Flow Chemistry GroupFraunhofer Institute for Microengineering and Microsystems IMM Carl-Zeiss-Straße 18–20 55129 Mainz Germany
| |
Collapse
|
19
|
Asano S, Yatabe S, Maki T, Mae K. Numerical and Experimental Quantification of the Performance of Microreactors for Scaling-up Fast Chemical Reactions. Org Process Res Dev 2019. [DOI: 10.1021/acs.oprd.8b00356] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Shusaku Asano
- Department of Chemical Engineering, Kyoto University, Kyoto 6158510, Japan
| | - Shota Yatabe
- Department of Chemical Engineering, Kyoto University, Kyoto 6158510, Japan
| | - Taisuke Maki
- Department of Chemical Engineering, Kyoto University, Kyoto 6158510, Japan
| | - Kazuhiro Mae
- Department of Chemical Engineering, Kyoto University, Kyoto 6158510, Japan
| |
Collapse
|
20
|
Grootveld M, Percival B, Gibson M, Osman Y, Edgar M, Molinari M, Mather ML, Casanova F, Wilson PB. Progress in low-field benchtop NMR spectroscopy in chemical and biochemical analysis. Anal Chim Acta 2019; 1067:11-30. [PMID: 31047142 DOI: 10.1016/j.aca.2019.02.026] [Citation(s) in RCA: 62] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2019] [Revised: 02/18/2019] [Accepted: 02/19/2019] [Indexed: 02/07/2023]
Abstract
The employment of spectroscopically-resolved NMR techniques as analytical probes have previously been both prohibitively expensive and logistically challenging in view of the large sizes of high-field facilities. However, with recent advances in the miniaturisation of magnetic resonance technology, low-field, cryogen-free "benchtop" NMR instruments are seeing wider use. Indeed, these miniaturised spectrometers are utilised in areas ranging from food and agricultural analyses, through to human biofluid assays and disease monitoring. Therefore, it is both intrinsically timely and important to highlight current applications of this analytical strategy, and also provide an outlook for the future, where this approach may be applied to a wider range of analytical problems, both qualitatively and quantitatively.
Collapse
Affiliation(s)
- Martin Grootveld
- Chemistry for Health/Bioanalytical Sciences Research Group, Leicester School of Pharmacy, De Montfort University, Leicester, LE1 9BH, UK
| | - Benita Percival
- Chemistry for Health/Bioanalytical Sciences Research Group, Leicester School of Pharmacy, De Montfort University, Leicester, LE1 9BH, UK
| | - Miles Gibson
- Chemistry for Health/Bioanalytical Sciences Research Group, Leicester School of Pharmacy, De Montfort University, Leicester, LE1 9BH, UK
| | - Yasan Osman
- Chemistry for Health/Bioanalytical Sciences Research Group, Leicester School of Pharmacy, De Montfort University, Leicester, LE1 9BH, UK
| | - Mark Edgar
- Department of Chemistry, University of Loughborough, Epinal Way, Loughborough, LE11 3TU, UK
| | - Marco Molinari
- School of Applied Sciences, University of Huddersfield, Queensgate, Huddersfield, HD1 3DH, UK
| | - Melissa L Mather
- Department of Electronic and Electrical Engineering, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | | | - Philippe B Wilson
- Chemistry for Health/Bioanalytical Sciences Research Group, Leicester School of Pharmacy, De Montfort University, Leicester, LE1 9BH, UK.
| |
Collapse
|
21
|
Sagmeister P, Williams JD, Hone CA, Kappe CO. Laboratory of the future: a modular flow platform with multiple integrated PAT tools for multistep reactions. REACT CHEM ENG 2019. [DOI: 10.1039/c9re00087a] [Citation(s) in RCA: 71] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The coupling of a modular microreactor platform, real-time inline analysis by IR and NMR, and online UPLC, leads to efficient optimization of a multistep organolithium transformation to a given product without the need for human intervention.
Collapse
Affiliation(s)
- Peter Sagmeister
- Center for Continuous Synthesis and Processing (CCFLOW)
- Research Center Pharmaceutical Engineering (RCPE)
- 8010 Graz
- Austria
- Institute of Chemistry
| | - Jason D. Williams
- Center for Continuous Synthesis and Processing (CCFLOW)
- Research Center Pharmaceutical Engineering (RCPE)
- 8010 Graz
- Austria
- Institute of Chemistry
| | - Christopher A. Hone
- Center for Continuous Synthesis and Processing (CCFLOW)
- Research Center Pharmaceutical Engineering (RCPE)
- 8010 Graz
- Austria
- Institute of Chemistry
| | - C. Oliver Kappe
- Center for Continuous Synthesis and Processing (CCFLOW)
- Research Center Pharmaceutical Engineering (RCPE)
- 8010 Graz
- Austria
- Institute of Chemistry
| |
Collapse
|
22
|
Galaverna R, Ribessi RL, Rohwedder JJR, Pastre JC. Coupling Continuous Flow Microreactors to MicroNIR Spectroscopy: Ultracompact Device for Facile In-Line Reaction Monitoring. Org Process Res Dev 2018. [DOI: 10.1021/acs.oprd.8b00060] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Renan Galaverna
- Institute of Chemistry, University of Campinas - UNICAMP, P.O. Box 6154, 13083-970 Campinas-SP, Brazil
| | - Rafael L. Ribessi
- Institute of Chemistry, University of Campinas - UNICAMP, P.O. Box 6154, 13083-970 Campinas-SP, Brazil
| | - Jarbas J. R. Rohwedder
- Institute of Chemistry, University of Campinas - UNICAMP, P.O. Box 6154, 13083-970 Campinas-SP, Brazil
| | - Julio C. Pastre
- Institute of Chemistry, University of Campinas - UNICAMP, P.O. Box 6154, 13083-970 Campinas-SP, Brazil
| |
Collapse
|
23
|
Rodrigues EJDR, Neto RPC, Sebastião PJO, Tavares MIB. Real-time monitoring by proton relaxometry of radical polymerization reactions of acrylamide in aqueous solution. POLYM INT 2018. [DOI: 10.1002/pi.5546] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Elton Jorge da Rocha Rodrigues
- Instituto de Macromoléculas Professora Eloisa Mano da Unidade Federal do Rio de Janeiro; Centro de Tecnologia, Ilha do Fundão; Rio de Janeiro Brazil
| | - Roberto Pinto Cucinelli Neto
- Instituto de Macromoléculas Professora Eloisa Mano da Unidade Federal do Rio de Janeiro; Centro de Tecnologia, Ilha do Fundão; Rio de Janeiro Brazil
| | - Pedro José Oliveira Sebastião
- Center of Physics and Engineering of Advanced Materials, Instituto Superior Técnico; Universidade de Lisboa; Portugal
| | - Maria Inês Bruno Tavares
- Instituto de Macromoléculas Professora Eloisa Mano da Unidade Federal do Rio de Janeiro; Centro de Tecnologia, Ilha do Fundão; Rio de Janeiro Brazil
| |
Collapse
|
24
|
Nekkaa I, Palkó M, Mándity IM, Fülöp F. Continuous-flow retro-Diels-Alder reaction: an efficient method for the preparation of pyrimidinone derivatives. Beilstein J Org Chem 2018; 14:318-324. [PMID: 29507637 PMCID: PMC5815275 DOI: 10.3762/bjoc.14.20] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2017] [Accepted: 01/22/2018] [Indexed: 01/06/2023] Open
Abstract
The syntheses of various pyrimidinones as potentially bioactive products by means of the highly controlled continuous-flow retro-Diels-Alder reaction of condensed pyrimidinone derivatives are presented. Noteworthy, the use of this approach allowed us to rapidly screen a selection of conditions and quickly confirm the viability of preparing the desired pyrimidinones in short reaction times. Yields typically higher than those published earlier using conventional batch or microwave processes were achieved.
Collapse
Affiliation(s)
- Imane Nekkaa
- Institute of Pharmaceutical Chemistry, University of Szeged, Eötvös u. 6, H-6720 Szeged, Hungary
| | - Márta Palkó
- Institute of Pharmaceutical Chemistry, University of Szeged, Eötvös u. 6, H-6720 Szeged, Hungary
| | - István M Mándity
- Institute of Pharmaceutical Chemistry, University of Szeged, Eötvös u. 6, H-6720 Szeged, Hungary
| | - Ferenc Fülöp
- Institute of Pharmaceutical Chemistry, University of Szeged, Eötvös u. 6, H-6720 Szeged, Hungary.,MTA-SZTE Stereochemistry Research Group, Hungarian Academy of Sciences, Eötvös u. 6, H-6720 Szeged, Hungary
| |
Collapse
|
25
|
Giraudeau P, Felpin FX. Flow reactors integrated with in-line monitoring using benchtop NMR spectroscopy. REACT CHEM ENG 2018. [DOI: 10.1039/c8re00083b] [Citation(s) in RCA: 62] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
The state-of-the-art flow reactors integrated with in-line benchtop NMR are thoroughly discussed with highlights on the strengths and weaknesses of this emerging technology.
Collapse
Affiliation(s)
- Patrick Giraudeau
- UFR des Sciences et des Techniques
- CNRS UMR 6230
- CEISAM
- Université de Nantes
- 44322 Nantes Cedex 3
| | - François-Xavier Felpin
- UFR des Sciences et des Techniques
- CNRS UMR 6230
- CEISAM
- Université de Nantes
- 44322 Nantes Cedex 3
| |
Collapse
|
26
|
Blümich B, Singh K. Desktop NMR and Its Applications From Materials Science To Organic Chemistry. Angew Chem Int Ed Engl 2017; 57:6996-7010. [PMID: 29230908 DOI: 10.1002/anie.201707084] [Citation(s) in RCA: 56] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2017] [Indexed: 12/19/2022]
Abstract
NMR spectroscopy is an indispensable method of analysis in chemistry, which until recently suffered from high demands for space, high costs for acquisition and maintenance, and operational complexity. This has changed with the introduction of compact NMR spectrometers suitable for small-molecule analysis on the chemical workbench. These spectrometers contain permanent magnets giving rise to proton NMR frequencies between 40 and 80 MHz. The enabling technology is to make small permanent magnets with homogeneous fields. Tabletop instruments with inhomogeneous fields have been in use for over 40 years for characterizing food and hydrogen-containing materials by relaxation and diffusion measurements. Related NMR instruments measure these parameters in the stray field outside the magnet. They are used to inspect the borehole walls of oil wells and to test objects nondestructively. The state-of-the-art of NMR spectroscopy, imaging and relaxometry with compact instruments is reviewed.
Collapse
Affiliation(s)
- Bernhard Blümich
- Institut für Technische und Makromolekulare Chemie, RWTH Aachen University, Aachen, Germany
| | - Kawarpal Singh
- Institut für Technische und Makromolekulare Chemie, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
27
|
Blümich B, Singh K. NMR mit Tischgeräten und deren Anwendungen von der Materialwissenschaft bis zur organischen Chemie. Angew Chem Int Ed Engl 2017. [DOI: 10.1002/ange.201707084] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Bernhard Blümich
- Institut für Technische und Makromolekulare Chemie; RWTH Aachen University; Aachen Deutschland
| | - Kawarpal Singh
- Institut für Technische und Makromolekulare Chemie; RWTH Aachen University; Aachen Deutschland
| |
Collapse
|
28
|
Matviychuk Y, von Harbou E, Holland DJ. An experimental validation of a Bayesian model for quantification in NMR spectroscopy. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2017; 285:86-100. [PMID: 29127944 DOI: 10.1016/j.jmr.2017.10.009] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2017] [Revised: 10/20/2017] [Accepted: 10/21/2017] [Indexed: 06/07/2023]
Abstract
The traditional peak integration method for quantitative analysis in nuclear magnetic resonance (NMR) spectroscopy is inherently limited by its ability to resolve overlapping peaks and is susceptible to noise. The alternative model-based approaches not only extend quantification capabilities to these challenging examples but also provide a means for automation of the entire process of NMR data analysis. In this paper, we present a general model for an NMR signal that, in a principled way, takes into account the effects of chemical shifts, relaxation, lineshape imperfections, phasing, and baseline distortions. We test the model using both simulations and experiments, concentrating on simple spectra with well-resolved peaks where we expect conventional analysis to be effective. Our results of quantifying mixture compositions compare favorably with the established methods. At high SNR (>40dB), all approaches usually achieve for these test systems an absolute accuracy of at least 0.01mol/mol for the concentrations of all species. Our model-based approach is successful even for SNR<20dB; it achieves 0.05-0.1mol/mol accuracy in cases where precise phasing is practically impossible due to high levels of noise in the data.
Collapse
Affiliation(s)
- Yevgen Matviychuk
- University of Canterbury, Private Bag 4800, Cristchurch 8140, New Zealand.
| | - Erik von Harbou
- Technische Universität Kaiserslautern, Erwin-Schrödinger-Straße 44, 67663 Kaiserslautern, Germany
| | - Daniel J Holland
- University of Canterbury, Private Bag 4800, Cristchurch 8140, New Zealand
| |
Collapse
|