1
|
Rydberg M, Bruening ML, Manicke NE. Paper Spray Mass Spectrometry with On-Paper Electrokinetic Manipulations: Part-Per-Trillion Detection of Per/Polyfluoroalkyl Substances in Water and Opioids in Urine. Angew Chem Int Ed Engl 2024; 63:e202401729. [PMID: 38657037 DOI: 10.1002/anie.202401729] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Revised: 04/18/2024] [Accepted: 04/18/2024] [Indexed: 04/26/2024]
Abstract
We developed a simple, paper-based device that enables sensitive detection by mass spectrometry (MS) without solid phase extraction or other sample preparation. Using glass fiber filter papers within a 3D printed holder, the device employs electrokinetic manipulations to stack, separate, and desalt charged molecules on paper prior to spray into the MS. Due to counter-balanced electroosmotic flow and electrophoresis, charged analytes stack on the paper and desalting occurs in minutes. One end of the paper strip was cut into a sharp point and positioned near the inlet of a MS. The stacked analyte bands move toward the paper tip with the EOF where they are ionized by paper spray. The device was applied to analysis of PFAS in tap water with sub part-per-trillion detection limits in less than ten minutes with no sample pretreatment. Analysis of opioids in urine also occurs in minutes. The crucial parameters to enable stacking, separation, and MS ionization of both positively and negatively charged analytes were determined and optimized. Experimental and computational modeling studies confirm the electrokinetic stacking and analyte transport mechanisms. On-paper separations were carried out by stacking analyte bands at different locations depending on their electrophoretic mobility, achieving baseline separation in some cases.
Collapse
Affiliation(s)
- Magnus Rydberg
- Department of Chemistry and Chemical Biology, Indiana University-Purdue, University Indianapolis
| | - Merlin L Bruening
- Department of Chemical & Biomolecular Engineering, University of Notre Dame
| | - Nicholas E Manicke
- Department of Chemistry and Chemical Biology, Indiana University-Purdue, University Indianapolis
| |
Collapse
|
2
|
Zhang X, Yao J, Gong X, Sun J, Wang R, Wang L, Liu L, Huang Y. Paper electrophoretic enrichment-assisted ultrasensitive SERS detection. Food Chem 2024; 434:137416. [PMID: 37734149 DOI: 10.1016/j.foodchem.2023.137416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 09/03/2023] [Accepted: 09/04/2023] [Indexed: 09/23/2023]
Abstract
To achieve sensitive detection of trace substances in fluids by surface-enhanced Raman spectroscopy (SERS), effective enrichment of molecules at subwavelength regions (hot spots) with a large enhancement is adopted. In this work, a glass fibre paper with Ag nanoparticles (AgNPs) is employed for electrodynamic enrichment of analytes in fluids by paper electrophoresis integrated with field amplification sample stacking (FASS) and capillary effects to obtain both Raman and SERS convenient and sensitive detection. With the help of electrophoretic enrichment on the glass fibre paper and surface plasmon enhancement on the AgNPs, this paper electrophoretic enrichment could improve the detection limit of Raman and SERS detection by more than an order of magnitude, even achieving a SERS detection limit of 10-17 M for Nile Blue A. Furthermore, this flexible SERS detection method can also detect trace organic contaminants at the ppt level in aquaculture and food applications.
Collapse
Affiliation(s)
- Xiumei Zhang
- Chongqing Key Laboratory of Soft Condensed Matter Physics and Smart Materials, College of Physics, Chongqing University, Chongqing 400044, China
| | - Jingru Yao
- Chongqing Key Laboratory of Soft Condensed Matter Physics and Smart Materials, College of Physics, Chongqing University, Chongqing 400044, China
| | - Xiangnan Gong
- Analytical and Testing Center, Chongqing University, Chongqing 401331, China
| | - Jianfeng Sun
- Chongqing Key Laboratory of Soft Condensed Matter Physics and Smart Materials, College of Physics, Chongqing University, Chongqing 400044, China
| | - Runhui Wang
- Chongqing Key Laboratory of Soft Condensed Matter Physics and Smart Materials, College of Physics, Chongqing University, Chongqing 400044, China
| | - Li Wang
- School of Optoelectronics Engineering, Chongqing University, Chongqing 401331, China.
| | - Liyu Liu
- Chongqing Key Laboratory of Soft Condensed Matter Physics and Smart Materials, College of Physics, Chongqing University, Chongqing 400044, China
| | - Yingzhou Huang
- Chongqing Key Laboratory of Soft Condensed Matter Physics and Smart Materials, College of Physics, Chongqing University, Chongqing 400044, China.
| |
Collapse
|
3
|
Hemmateenejad B, Rafatmah E, Shojaeifard Z. Microfluidic paper and thread-based separations: Chromatography and electrophoresis. J Chromatogr A 2023; 1704:464117. [PMID: 37300912 DOI: 10.1016/j.chroma.2023.464117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 05/25/2023] [Accepted: 05/30/2023] [Indexed: 06/12/2023]
Abstract
Paper and thread are widely used as the substrates for fabricating low-cost, disposable, and portable microfluidic analytical devices used in clinical, environmental, and food safety monitoring. Concerning separation methods including chromatography and electrophoresis, these substrates provide unique platforms for developing portable devices. This review focuses on summarizing recent research on the miniaturization of the separation techniques using paper and thread. Preconcentration, purification, desalination, and separation of various analytes are achievable using electrophoresis and chromatography methods integrated with modified or unmodified paper/thread wicking channels. A variety of 2D and 3D designs of paper/thread platforms for zone electrophoresis, capillary electrophoresis, and modified/unmodified chromatography are discussed with emphasis on their limitation and improvements. The current progress in the signal amplification strategies such as isoelectric focusing, isotachophoresis, ion concentration polarization, isoelectric focusing, and stacking methods in paper-based devices are reviewed. Different strategies for chromatographic separations based on paper/thread will be explained. The separation of target species from complex samples and their determination by integration with other analytical methods like spectroscopy and electrochemistry are well-listed. Furthermore, the innovations for plasma and cell separation from blood as an important human biofluid are presented, and the related paper/thread modification methods are explored.
Collapse
|
4
|
Zhou Y, Niu J, Zhou Y, Li F. Liquid Plasticine-Based Electrokinetic Enrichment of Proteins. ChemistryOpen 2023; 12:e202200259. [PMID: 36971105 PMCID: PMC10041546 DOI: 10.1002/open.202200259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 03/07/2023] [Indexed: 03/29/2023] Open
Abstract
Protein analysis is an important approach for disease diagnosis, in which sample pretreatment is an essential step since protein samples are often complex and many protein biomarkers are of low abundance. Here, given the good openness and light transmission of liquid plasticine (LP), which is a liquid entity formed by SiO2 nanoparticles and encapsulated aqueous solution, we developed a LP-based field-amplified sample stacking (FASS) system for protein enrichment. The system was composed of a LP container, a sample solution and a Tris-HCl solution containing hydroxyethyl cellulose (HEC). The system design, mechanism investigation, optimization of experimental parameters and characterization of LP-FASS performance for protein enrichment were well studied. Under the optimized experimental conditions of 1 % HEC, 100 mm Tris-HCl and 100 V in the LP-FASS system, a 40-80 times enrichment of proteins was obtained in 40 min using bovine hemoglobin (BHb) as the model protein using the constructed LP-FASS system. The simultaneous enrichment of multiple proteins (phycocyanin, BHb and cytochrome C) was also realized using the system. The LP-FASS system can serve as a new platform for protein enrichment which is easy to be combined with online and offline detections.
Collapse
Affiliation(s)
- Yulin Zhou
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, 710049, Xi'an, P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, 710049, Xi'an, P. R. China
| | - Jicheng Niu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, 710049, Xi'an, P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, 710049, Xi'an, P. R. China
| | - Yan Zhou
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, 710049, Xi'an, P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, 710049, Xi'an, P. R. China
| | - Fei Li
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, 710049, Xi'an, P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, 710049, Xi'an, P. R. China
| |
Collapse
|
5
|
Ren WQ, Ji B, Kuang Z, Fang F, Guo XL, Wu ZY. Paper-based Analytical Device for Fast Colorimetric Detection of Total Hemoglobin and Free Hemoglobin from Human Blood Sample. Microchem J 2023. [DOI: 10.1016/j.microc.2022.108380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
6
|
Simultaneous enrichment and separation based on ion concentration polarization effect on a paper based analytical device. Anal Chim Acta 2022; 1208:339844. [DOI: 10.1016/j.aca.2022.339844] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 04/14/2022] [Accepted: 04/16/2022] [Indexed: 11/23/2022]
|
7
|
Fast and highly efficient multiplexed electrokinetic stacking on a paper-based analytical device. Microchem J 2022. [DOI: 10.1016/j.microc.2021.107041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
8
|
Tai WC, Chang YC, Chou D, Fu LM. Lab-on-Paper Devices for Diagnosis of Human Diseases Using Urine Samples-A Review. BIOSENSORS 2021; 11:260. [PMID: 34436062 PMCID: PMC8393526 DOI: 10.3390/bios11080260] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 07/26/2021] [Accepted: 07/29/2021] [Indexed: 12/23/2022]
Abstract
In recent years, microfluidic lab-on-paper devices have emerged as a rapid and low-cost alternative to traditional laboratory tests. Additionally, they were widely considered as a promising solution for point-of-care testing (POCT) at home or regions that lack medical infrastructure and resources. This review describes important advances in microfluidic lab-on-paper diagnostics for human health monitoring and disease diagnosis over the past five years. The review commenced by explaining the choice of paper, fabrication methods, and detection techniques to realize microfluidic lab-on-paper devices. Then, the sample pretreatment procedure used to improve the detection performance of lab-on-paper devices was introduced. Furthermore, an in-depth review of lab-on-paper devices for disease measurement based on an analysis of urine samples was presented. The review concludes with the potential challenges that the future development of commercial microfluidic lab-on-paper platforms for human disease detection would face.
Collapse
Affiliation(s)
- Wei-Chun Tai
- Department of Oral and Maxillofacial Surgery, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung 833, Taiwan;
| | - Yu-Chi Chang
- Department of Engineering Science, National Cheng Kung University, Tainan 701, Taiwan;
| | - Dean Chou
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan;
| | - Lung-Ming Fu
- Department of Engineering Science, National Cheng Kung University, Tainan 701, Taiwan;
- Graduate Institute of Materials Engineering, National Pingtung University of Science and Technology, Pingtung 912, Taiwan
| |
Collapse
|
9
|
Chen YZ, Niu BS, Ji B, Fang F, Guo XL, Wu ZY. Salty Biofluidic Sample Clean-Up and Preconcentration with a Paper-Based Ion Concentration Polarization Interface. Anal Chem 2021; 93:10236-10242. [PMID: 34269555 DOI: 10.1021/acs.analchem.1c01640] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Charged species from complex media could be separated and enriched taking advantage of ion concentration polarization (ICP) effect; thus, ICP can be used for sample purification and improvement of detection sensitivity. In this paper, a novel and reliable ICP interface was established on a paper-based analytical device (PAD) by using ion exchange membrane, and electrokinetic stacking of target analytes from salty media was successfully demonstrated. Steady ICP effect was well observed in aqueous solution with up to 400 mM NaCl as shown by a fluorescent probe, which makes it possible to directly process salty physiological samples such as blood and urine with this type of PAD. Application of this method was demonstrated by direct online stacking of total protein from urine samples and image-based colorimetric detection by a smartphone camera. The linear response was in the range of 50-350 mg/L (R2 = 0.99), with recovery rate in the range of 94.8-107.6% and relative standard deviation below 7.1%. The obtained results were consistent with that of the clinical method. As an off-line sample pretreatment method, the feasibility for rapid tandem mass spectrometry detection of amino acids from serum samples was also investigated, and promising results were obtained. This PAD method is of low cost, easy to operate, and reliable. As a disposable PAD, it is useful not only for sensitive point-of-care testing but also for direct purification and concentration of complex and highly conductive physiological samples for fast and accurate detection with advanced analytical instruments.
Collapse
Affiliation(s)
- Yu-Zhu Chen
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang 110819, China
| | - Bing-Su Niu
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang 110819, China
| | - Bin Ji
- The First Affiliated Hospital of China Medical University, Shenyang 110001, China
| | - Fang Fang
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang 110819, China
| | - Xiao-Lin Guo
- The First Affiliated Hospital of China Medical University, Shenyang 110001, China
| | - Zhi-Yong Wu
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang 110819, China
| |
Collapse
|
10
|
Zhai HM, Ji B, Tian SS, Fang F, Zhao S, Wu ZY. Cr speciation analysis based on electrokinetic sample pretreatment with a paper based analytical device. Talanta 2021; 234:122656. [PMID: 34364465 DOI: 10.1016/j.talanta.2021.122656] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 06/22/2021] [Accepted: 06/23/2021] [Indexed: 11/25/2022]
Abstract
This work presents a new method of Cr speciation analysis based on micro sample pretreatment with a paper-based analytical device (PAD). By using electrokinetic separation and stacking on the PAD, Cr (VI) and Cr (III) can be separated and the recovered to achieve speciation analysis without have to be subjected to subtraction treatment. The separation and recovery properties of Cr (VI) and Cr (III) were characterized and optimized by UV-Vis spectrophotometry, with which the LOQ of 19.0 μg L-1 and 28.7 μg L-1, and the recoveries of 88-108% and 90-110%, were obtained for Cr (VI) and Cr (III), respectively. In addition, direct analysis of Cr (VI)/Cr (III) from an electroplating wastewater sample was also demonstrated with this method combined with atomic spectroscopy (GF-AAS and ICP-OES). This sample pretreatment method is fast, cheap and easy to be used. Combined with the high sensitivity and elemental selectivity of atomic spectroscopy and mass spectrometry, this PAD sample pretreatment method could be a compensation to their lack in speciation discrimination, and may play an important role in the speciation analysis of Cr.
Collapse
Affiliation(s)
- Hui-Min Zhai
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China
| | - Bin Ji
- The First Affiliated Hospital of China Medical University, Shenyang, 110819, China
| | - Shan-Shan Tian
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China
| | - Fang Fang
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China
| | - Shuang Zhao
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China
| | - Zhi-Yong Wu
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China.
| |
Collapse
|
11
|
Ng HY, Lee WC, Kung CT, Li LC, Lee CT, Fu LM. Recent Advances in Microfluidic Devices for Contamination Detection and Quality Inspection of Milk. MICROMACHINES 2021; 12:558. [PMID: 34068982 PMCID: PMC8156775 DOI: 10.3390/mi12050558] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 05/05/2021] [Accepted: 05/11/2021] [Indexed: 02/08/2023]
Abstract
Milk is a necessity for human life. However, it is susceptible to contamination and adulteration. Microfluidic analysis devices have attracted significant attention for the high-throughput quality inspection and contaminant analysis of milk samples in recent years. This review describes the major proposals presented in the literature for the pretreatment, contaminant detection, and quality inspection of milk samples using microfluidic lab-on-a-chip and lab-on-paper platforms in the past five years. The review focuses on the sample separation, sample extraction, and sample preconcentration/amplification steps of the pretreatment process and the determination of aflatoxins, antibiotics, drugs, melamine, and foodborne pathogens in the detection process. Recent proposals for the general quality inspection of milk samples, including the viscosity and presence of adulteration, are also discussed. The review concludes with a brief perspective on the challenges facing the future development of microfluidic devices for the analysis of milk samples in the coming years.
Collapse
Affiliation(s)
- Hwee-Yeong Ng
- Division of Nephrology, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung 833, Taiwan; (H.-Y.N.); (W.-C.L.); (L.-C.L.); (C.-T.L.)
| | - Wen-Chin Lee
- Division of Nephrology, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung 833, Taiwan; (H.-Y.N.); (W.-C.L.); (L.-C.L.); (C.-T.L.)
| | - Chia-Te Kung
- Department of Emergency Medicine, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung 833, Taiwan;
| | - Lung-Chih Li
- Division of Nephrology, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung 833, Taiwan; (H.-Y.N.); (W.-C.L.); (L.-C.L.); (C.-T.L.)
| | - Chien-Te Lee
- Division of Nephrology, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung 833, Taiwan; (H.-Y.N.); (W.-C.L.); (L.-C.L.); (C.-T.L.)
| | - Lung-Ming Fu
- Department of Engineering Science, National Cheng Kung University, Tainan 701, Taiwan
| |
Collapse
|
12
|
Lee WC, Ng HY, Hou CY, Lee CT, Fu LM. Recent advances in lab-on-paper diagnostic devices using blood samples. LAB ON A CHIP 2021; 21:1433-1453. [PMID: 33881033 DOI: 10.1039/d0lc01304h] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Lab-on-paper, or microfluidic paper-based analytical devices (μPADs), use paper as a substrate material, and are patterned with a system of microchannels, reaction zones and sensing elements to perform analysis and detection. The sample transfer in such devices is performed by capillary action. As a result, external driving forces are not required, and hence the size and cost of the device are significantly reduced. Lab-on-paper devices have thus attracted significant attention for point-of-care medical diagnostic purposes in recent years, particularly in less-developed regions of the world lacking medical resources and infrastructures. This review discusses the major advances in lab-on-paper technology for blood analysis and diagnosis in the past five years. The review focuses particularly on the many clinical applications of lab-on-paper devices, including diabetes diagnosis, acute myocardial infarction (AMI) detection, kidney function diagnosis, liver function diagnosis, cholesterol and triglyceride (TG) analysis, sickle-cell disease (SCD) and phenylketonuria (PKU) analysis, virus analysis, C-reactive protein (CRP) analysis, blood ion analysis, cancer factor analysis, and drug analysis. The review commences by introducing the basic transmission principles, fabrication methods, structural characteristics, detection techniques, and sample pretreatment process of modern lab-on-paper devices. A comprehensive review of the most recent applications of lab-on-paper devices to the diagnosis of common human diseases using blood samples is then presented. The review concludes with a brief summary of the main challenges and opportunities facing the lab-on-paper technology field in the coming years.
Collapse
Affiliation(s)
- Wen-Chin Lee
- Division of Nephrology, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung, 833, Taiwan.
| | - Hwee-Yeong Ng
- Division of Nephrology, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung, 833, Taiwan.
| | - Chih-Yao Hou
- Department of Seafood Science, National Kaohsiung University of Science and Technology, Kaohsiung 811, Taiwan
| | - Chien-Te Lee
- Division of Nephrology, Kaohsiung Chang Gung Memorial Hospital, College of Medicine, Chang Gung University, Kaohsiung, 833, Taiwan.
| | - Lung-Ming Fu
- Department of Engineering Science, National Cheng Kung University, Tainan, 701, Taiwan.
| |
Collapse
|
13
|
Zhiyue M, Xichen Y, Li R, Yang Y, Huicheng F, Peng S. Recent advances in paper-based preconcentrators by utilizing ion concentration polarization. Electrophoresis 2021; 42:1340-1351. [PMID: 33768593 DOI: 10.1002/elps.202000291] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 02/26/2021] [Accepted: 03/15/2021] [Indexed: 11/09/2022]
Abstract
One of the most cited limitations of biochemical detection is its poor sensitivity, owing to the relatively high complexity of micro-samples. Moreover, some samples cannot be easily self-replicated and their abundance cannot be increased through traditional technologies. Therefore, the preconcentration of low-abundance samples is a key requirement for microfluidic biological analysis. In recent years, the ion-concentration polarization phenomenon has aroused widespread interest in the application of microfluidic technology. In addition, paper-based materials are readily available, easy to modify, and exhibit good hydrophilicity. The study of the ion-concentration polarization preconcentration of micro-samples in paper-based microfluidic chips is of considerable significance. In this review, we discuss the development and applications of ion-concentration polarization paper-based preconcentrator in the past 5 years, with emphasis on key progresses in chip fabrication and performance optimization under different conditions. The current needs and development prospects in this field have also been discussed.
Collapse
Affiliation(s)
- Meng Zhiyue
- School of Life Sciences, Northwestern Polytechnical University, Xi'an, P. R. China.,Key Laboratory for Space Bioscience and Biotechnology, Institute of Special Environment Biophysics, Northwestern Polytechnical University, Xi'an, P. R. China
| | - Yuan Xichen
- School of Life Sciences, Northwestern Polytechnical University, Xi'an, P. R. China.,Research and Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, P. R. China.,Key Laboratory for Space Bioscience and Biotechnology, Institute of Special Environment Biophysics, Northwestern Polytechnical University, Xi'an, P. R. China.,Yangtze River Delta Research Institute of Northwestern Polytechnical University, Taicang, P. R. China
| | - Ren Li
- School of Life Sciences, Northwestern Polytechnical University, Xi'an, P. R. China.,Research and Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, P. R. China.,Key Laboratory for Space Bioscience and Biotechnology, Institute of Special Environment Biophysics, Northwestern Polytechnical University, Xi'an, P. R. China
| | - Yang Yang
- Ministry of Education Key Laboratory of Low-grade Energy Utilization Technologies and Systems, Chongqing University, Chongqing, P. R. China
| | - Feng Huicheng
- Unmanned System Research Institute, Northwestern Polytechnical University, Xi'an, P. R. China.,MOE Key Laboratory of Micro and Nano Systems for Aerospace, Northwestern Polytechnical University, Xi'an, P. R. China
| | - Shang Peng
- School of Life Sciences, Northwestern Polytechnical University, Xi'an, P. R. China.,Research and Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, P. R. China.,Key Laboratory for Space Bioscience and Biotechnology, Institute of Special Environment Biophysics, Northwestern Polytechnical University, Xi'an, P. R. China
| |
Collapse
|
14
|
Davies CD, Crooks RM. Focusing, sorting, and separating microplastics by serial faradaic ion concentration polarization. Chem Sci 2020; 11:5547-5558. [PMID: 32874498 PMCID: PMC7441690 DOI: 10.1039/d0sc01931c] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Accepted: 05/13/2020] [Indexed: 12/16/2022] Open
Abstract
In this article, we report continuous sorting of two microplastics in a trifurcated microfluidic channel using a new method called serial faradaic ion concentration polarization (fICP). fICP is an electrochemical method for forming ion depletion zones and their corresponding locally elevated electric fields in microchannels. By tuning the interplay between the forces of electromigration and convection during a fICP experiment, it is possible to control the flow of charged objects in microfluidic channels. The key findings of this report are threefold. First, fICP at two bipolar electrodes, configured in series and operated with a single power supply, yields two electric field gradients within a single microfluidic channel (i.e., serial fICP). Second, complex flow variations that adversely impact separations during fICP can be mitigated by minimizing convection by electroosmotic flow in favor of pressure-driven flow. Finally, serial fICP within a trifurcated microchannel is able to continuously and quantitatively focus, sort, and separate microplastics. These findings demonstrate that multiple local electric field gradients can be generated within a single microfluidic channel by simply placing metal wires at strategic locations. This approach opens a vast range of new possibilities for implementing membrane-free separations.
Collapse
Affiliation(s)
- Collin D Davies
- Department of Chemistry and Texas Materials Institute , The University of Texas at Austin , 105 E. 24th St., Stop A5300 , Austin , Texas , 78712-1224 , USA . ; Tel: +1-512-475-8674
| | - Richard M Crooks
- Department of Chemistry and Texas Materials Institute , The University of Texas at Austin , 105 E. 24th St., Stop A5300 , Austin , Texas , 78712-1224 , USA . ; Tel: +1-512-475-8674
| |
Collapse
|
15
|
Xie MR, Cai Y, Liu YQ, Wu ZY. Sensitive colorimetric detection of Pb 2+ by geometric field amplification and surface plasmon resonance visualization. Talanta 2020; 212:120749. [PMID: 32113532 DOI: 10.1016/j.talanta.2020.120749] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Revised: 01/13/2020] [Accepted: 01/14/2020] [Indexed: 11/15/2022]
Abstract
Pb2+ is one of the major environmental pollutants, which can be visually detected by surface plasmon resonance of nanoparticles. Paper based analytical device, as a newly developed microfluidic detection platform, is featured in cost-effective and suitable for on-site analysis. In this paper, a sensitive and portable detection method for Pb2+ was proposed, in which Pb2+ was electrokinetically stacked on the paper fluidic channel by geometric field amplification effect and visualized online by glutathione-modified silver nanoparticles. Colorimetric quantification of the visualized stacking band was conducted by smart phone camera. To avoid unfavorable influence from pH change on the surface plasmon resonance visualization, field amplification effect was introduced by geometric design of the paper fluidic channel. The enriched Pb2+ was clearly visible on the paper substrate, and the stacking band intensity was about four orders of magnitude enhanced, comparing to the intensity without stacking. A linear response to Pb2+ was observed in the range of 0.3-7.0 μM (R2 = 0.997) with a limit of detection of 86 nM and a limit of quantity of 0.28 μM. The established method was used in the detection of Pb2+ from river and lake water samples, and the results were confirmed by atomic absorption spectroscopy method.
Collapse
Affiliation(s)
- Mao-Rong Xie
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China
| | - Yu Cai
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China
| | - Yu-Qi Liu
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China
| | - Zhi-Yong Wu
- Research Center for Analytical Sciences, Chemistry Department, College of Sciences, Northeastern University, Shenyang, 110819, China.
| |
Collapse
|
16
|
Mani NK, Das SS, Dawn S, Chakraborty S. Electro-kinetically driven route for highly sensitive blood pathology on a paper-based device. Electrophoresis 2020; 41:615-620. [PMID: 31891191 DOI: 10.1002/elps.201900356] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2019] [Revised: 10/30/2019] [Accepted: 12/23/2019] [Indexed: 12/15/2022]
Abstract
Enhancing the sensitivity of colorimetric detection in paper-devices is a quintessential step in achieving frugal diagnosis. Here, we demonstrate an effective way of improving the detection sensitivity of paper-based devices, as mediated by electro-kinetic mechanisms. By directly employing blood plasma, we investigate the electro-kinetic clustering of glucose, a neutral molecule in paper devices. Under the influence of uniform electric field, dispersed glucose gets accumulated in the paper strips. Due to the combination of EOF and electrophoretic migration, we achieve twofold increase in the colour intensity for both normal and diabetic samples. This approach is robust and possesses better sensitivity than conventional colorimetric assays and can be easily extended to other body fluid based diagnosis. These results may turn out to be of profound importance in improving the quality of pathological diagnosis in low-cost paper-based point-of-care devices deployed in resource-limited settings.
Collapse
Affiliation(s)
- Naresh Kumar Mani
- Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, India
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India
| | - Sankha Shuvra Das
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India
| | - Sayantan Dawn
- Department of Mechanical Engineering, Jadavpur University, Kolkata, India
| | - Suman Chakraborty
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India
| |
Collapse
|
17
|
Nano-electrokinetic ion enrichment in a micro-nanofluidic preconcentrator with nanochannel’s Cantor fractal wall structure. APPLIED NANOSCIENCE 2019. [DOI: 10.1007/s13204-019-01049-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|