1
|
Chen K, Wan Q, Wei S, Nie W, Zhou S, Chen S. Recent Advances in On-Line Mass Spectrometry Toolbox for Mechanistic Studies of Organic Electrochemical Reactions. Chemistry 2024; 30:e202402215. [PMID: 39083258 DOI: 10.1002/chem.202402215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2024] [Indexed: 09/25/2024]
Abstract
Electrochemical reactions are very complex and involve a variety of physicochemical processes. Accurate and systematic monitoring of intermediate process changes during the reaction is essential for understanding the mechanism of electrochemical reactions and is the basis for rational design of new electrochemical reactions. On-line electrochemical analysis based on mass spectrometry (MS) has become an important tool for studying electrochemical reactions. This technique is based on different ionization and sampling means and realizes on-line analysis of electrochemical reactions by establishing electrochemistry-MS (EC-MS) coupling devices. In particular, it provides key evidence for elucidating the reaction mechanism by capturing and identifying the reactive reaction intermediates. This review will categorize various EC-MS devices and the organic electrochemical reaction systems they study, highlighting the latest research progress in recent years. It will also analyze the properties of various devices and look forward to the future development of EC-MS.
Collapse
Affiliation(s)
- Kaixiang Chen
- The Institute for Advanced Studies, Wuhan University, Wuhan, Hubei, 430072, China
| | - Qiongqiong Wan
- The Institute for Advanced Studies, Wuhan University, Wuhan, Hubei, 430072, China
| | - Shiqi Wei
- The Institute for Advanced Studies, Wuhan University, Wuhan, Hubei, 430072, China
| | - Wenjin Nie
- The Institute for Advanced Studies, Wuhan University, Wuhan, Hubei, 430072, China
| | - Shibo Zhou
- The Institute for Advanced Studies, Wuhan University, Wuhan, Hubei, 430072, China
| | - Suming Chen
- The Institute for Advanced Studies, Wuhan University, Wuhan, Hubei, 430072, China
| |
Collapse
|
2
|
Freitas D, Chen X, Cheng H, Davis A, Fallon B, Yan X. Recent Advances of In-Source Electrochemical Mass Spectrometry. Chempluschem 2021; 86:434-445. [PMID: 33689239 DOI: 10.1002/cplu.202100030] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2021] [Revised: 03/03/2021] [Indexed: 12/16/2022]
Abstract
Hyphenation of electrochemistry (EC) and mass spectrometry has become a powerful tool to study redox processes. Approaches that can achieve this hyphenation include integrating chromatography/electrophoresis between electroinduced redox reactions and detection of products, coupling an EC flow cell to a mass spectrometer, and performing electrochemical reactions inside the ion source of a mass spectrometer. The first two approaches have been well reviewed elsewhere. This Minireview highlights the inherent electrochemical properties of many mass spectrometry ion sources and their roles in the coupling of electrochemistry and mass spectrometric analysis. Development of modified ion sources that allow the compatibility of electrochemistry with ionization processes is also surveyed. Applications of different in-source electrochemical devices are provided including intermediate capturing, bioanalytical studies, nanoparticle formation, electrosynthesis, and electrode imaging.
Collapse
Affiliation(s)
- Dallas Freitas
- Department of Chemistry, Texas A&M University, 580 Ross St., College Station, TX 77843, USA
| | - Xi Chen
- Department of Chemistry, Texas A&M University, 580 Ross St., College Station, TX 77843, USA
| | - Heyong Cheng
- Department of Chemistry, Texas A&M University, 580 Ross St., College Station, TX 77843, USA
| | - Austin Davis
- Department of Chemistry, Texas A&M University, 580 Ross St., College Station, TX 77843, USA
| | - Blake Fallon
- Department of Chemistry, Texas A&M University, 580 Ross St., College Station, TX 77843, USA
| | - Xin Yan
- Department of Chemistry, Texas A&M University, 580 Ross St., College Station, TX 77843, USA
| |
Collapse
|
3
|
Chen L, Ghiasvand A, Rodriguez ES, Innis PC, Paull B. Applications of nanomaterials in ambient ionization mass spectrometry. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116202] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
4
|
Wang H, Wang X, Zhao M, Shi C, Ma C. Ratiometric Electrochemical Biosensor for the Sensitive Determination of DNA by a Hairpin DNA Probe. ANAL LETT 2021. [DOI: 10.1080/00032719.2020.1871001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Haixia Wang
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, China
| | - Xuejiao Wang
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, China
| | - Mingyuan Zhao
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, China
| | - Chao Shi
- Qingdao Nucleic Acid Rapid Testing International Science and Technology Cooperation Base, College of Life Sciences, Department of Pathogenic Biology, School of Basic Medicine, and Department of Clinical Laboratory, The Affiliated Hospital of Qingdao University, Qingdao University, Qingdao, China
| | - Cuiping Ma
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, China
| |
Collapse
|
5
|
Basuri P, Das S, Jenifer SK, Jana SK, Pradeep T. Microdroplet Impact-Induced Spray Ionization Mass Spectrometry (MISI MS) for Online Reaction Monitoring and Bacteria Discrimination. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:355-363. [PMID: 33200609 DOI: 10.1021/jasms.0c00365] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Microdroplet impact-induced spray ionization (MISI) is demonstrated involving the impact of microdroplets produced from a paper and their impact on another, leading to the ionization of analytes deposited on the latter. This cascaded process is more advantageous in comparison to standard spray ionization as it performs reactions and ionization simultaneously in the absence of high voltage directly applied on the sample. In MISI, we apply direct current (DC) potential only to the terminal paper, used as the primary ion source. Charge transfer due to microdroplet/ion deposition on the flowing analyte solution on the second surface generates secondary charged microdroplets from it carrying the analytes, which ionize and get detected by a mass spectrometer. In this way, up to three cascaded spray sources could be assembled in series. We show the detection of small molecules and proteins in such ionization events. MISI provides a method to understand chemical reactions by droplet impact. The C-C bond formation reactions catalyzed by palladium and alkali metal ion encapsulation using crown ether were studied as our model reactions. To demonstrate the application of our ion source in a bioanalytical context, we studied the noninvasive in situ discrimination of bacteria samples under ambient conditions.
Collapse
Affiliation(s)
- Pallab Basuri
- DST Unit of Nanoscience (DST UNS) and Thematic Unit of Excellence (TUE), Department of Chemistry, Indian Institute of Technology Madras, Chennai 600036, India
| | - Subhashree Das
- DST Unit of Nanoscience (DST UNS) and Thematic Unit of Excellence (TUE), Department of Chemistry, Indian Institute of Technology Madras, Chennai 600036, India
| | - Shantha Kumar Jenifer
- DST Unit of Nanoscience (DST UNS) and Thematic Unit of Excellence (TUE), Department of Chemistry, Indian Institute of Technology Madras, Chennai 600036, India
| | - Sourav Kanti Jana
- DST Unit of Nanoscience (DST UNS) and Thematic Unit of Excellence (TUE), Department of Chemistry, Indian Institute of Technology Madras, Chennai 600036, India
| | - Thalappil Pradeep
- DST Unit of Nanoscience (DST UNS) and Thematic Unit of Excellence (TUE), Department of Chemistry, Indian Institute of Technology Madras, Chennai 600036, India
| |
Collapse
|
6
|
Song X, Chen H, Zare RN. Coulometry-assisted quantitation in spray ionization mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2020; 56:e4628. [PMID: 33245185 DOI: 10.1002/jms.4628] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2020] [Revised: 06/16/2020] [Accepted: 06/23/2020] [Indexed: 06/11/2023]
Abstract
The concentration of target analyte in a mixture can be quantified by combining coulometric measurements with spray ionization mass spectrometry. A three-electrode system screen printed on the polymer support acts both as the coulometry platform for electrochemical oxidation and the sample loading tip for spray ionization. After loading a droplet of the analyte solution onto the tip, two steps were taken to implement quantitation. First, the electrochemical oxidation potential was optimized with cyclic voltammetry followed by coulometric measurements to calculate the amount of oxidized analyte under a constant low voltage within a fixed period of time (5 s). Then, a high voltage (+4.5 kV) was applied to the tip to trigger spray ionization for measuring the oxidation yield from the native analyte ion and its oxidized product ion intensities by mass spectrometry. The analyte's native concentration is quantified by dividing the oxidized product's concentration (based on Coulomb's law) and the oxidation yield (estimated from mass spectrometry [MS] assuming that the parent and oxidation product have nearly the same ionization efficiencies). The workflow has an advantage in being free of any standard for constructing the quantitation curve. Several model compounds (tyrosine, dopamine, and angiotensin II) were selected for method validation. It was demonstrated that this strategy was feasible with an accuracy of ~15% for a wide coverage of different species including endogenous metabolites and peptides. As an example of its possible practical use, it was initially employed to make a bilirubin assay in urine.
Collapse
Affiliation(s)
- Xiaowei Song
- Department of Chemistry, Fudan University, Shanghai, 200438, China
| | - Hao Chen
- Department of Chemistry and Environmental Science, New Jersey Institute of Technology, Newark, NJ, 07102, USA
| | - Richard N Zare
- Department of Chemistry, Fudan University, Shanghai, 200438, China
- Department of Chemistry, Stanford University, Stanford, CA, 94305, USA
| |
Collapse
|
7
|
Wang X, Niu S, Wei M, Liu S, Liu R, Shi C, Ma C. Ultrasensitive electrochemical DNA biosensor based on a tetrahedral structure and proximity-dependent surface hybridization. Analyst 2020; 145:150-156. [PMID: 31720590 DOI: 10.1039/c9an01897b] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
The DNA tetrahedron has developed a broad spectrum of applications in biosensor construction thanks to its excellent mechanical rigidity and structural stability. However, how to construct a highly sensitive biosensor using a DNA tetrahedron is still a challenge. In this work, an ultrasensitive electrochemical biosensor based on a DNA tetrahedral nanostructure was developed with the help of synergy from proximity-dependent hybridization. To decrease the steric hindrance of DNA tetrahedra to proximity-dependent hybridization, the detection signal was set on the inclined side chain structure of a DNA tetrahedral sensing system. Additionally, when the target hybridized with the DNA probe, the ferrocene (Fc) labeled on the end of the DNA probe was driven close to the surface of the biosensor, providing a sensitive faradaic current. The experimental results exhibited a good linear relationship from 1 fM to 10 pM with a linear correlation coefficient of 0.9977, and a high sensitivity with a detection limit of 0.2 fM. Our DNA biosensor also showed good stability according to electrode characterization and target detection at different time scales and the anti-jamming capabilities in a complicated biological extraction environment were excellent. The electrochemical sensing system established here has greatly improved the detection sensitivity of a DNA biosensor based on a DNA tetrahedron, which will further promote its practical applications.
Collapse
Affiliation(s)
- Xuejiao Wang
- Shandong Provincial Key Laboratory of Biochemical Engineering, Key Laboratory of Sensor Analysis of Tumor Marker, Ministry of Education, Shandong Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao 266042, PR China.
| | | | | | | | | | | | | |
Collapse
|
8
|
Affiliation(s)
- Thomas Herl
- Institute of Analytical Chemistry, Chemo- and BiosensorsUniversity of Regensburg Universitätsstraße 31 93053 Regensburg Germany
| | - Frank‐Michael Matysik
- Institute of Analytical Chemistry, Chemo- and BiosensorsUniversity of Regensburg Universitätsstraße 31 93053 Regensburg Germany
| |
Collapse
|
9
|
Adarsh KS, Chandrasekaran N, Chakrapani V. In-situ Spectroscopic Techniques as Critical Evaluation Tools for Electrochemical Carbon dioxide Reduction: A Mini Review. Front Chem 2020; 8:137. [PMID: 32266204 PMCID: PMC7099648 DOI: 10.3389/fchem.2020.00137] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Accepted: 02/14/2020] [Indexed: 11/13/2022] Open
Abstract
Electrocatalysis plays a crucial role in modern electrochemical energy conversion technologies as a greener replacement for conventional fossil fuel-based systems. Catalysts employed for electrochemical conversion reactions are expected to be cheaper, durable, and have a balance of active centers (for absorption of the reactants, intermediates formed during the reactions), porous, and electrically conducting material to facilitate the flow of electrons for real-time applications. Spectroscopic and microscopic studies on the electrode-electrolyte interface may lead to better understanding of the structural and compositional deviations occurring during the course of electrochemical reaction. Researchers have put significant efforts in the past decade toward understanding the mechanistic details of electrochemical reactions which resulted in hyphenation of electrochemical-spectroscopic/microscopic techniques. The hyphenation of diverse electrochemical and conventional microscopic, spectroscopic, and chromatographic techniques, in addition to the elementary pre-screening of electrocatalysts using computational methods, have gained deeper understanding of the electrode-electrolyte interface in terms of activity, selectivity, and durability throughout the reaction process. The focus of this mini review is to summarize the hyphenated electrochemical and non-electrochemical techniques as critical evaluation tools for electrocatalysts in the CO2 reduction reaction.
Collapse
Affiliation(s)
- K. S. Adarsh
- CSIR-Central Electrochemical Research Institute, Karaikudi, India
| | | | - Vidhya Chakrapani
- Howard P. Isermann Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, NY, United States
| |
Collapse
|