1
|
Guan MY, Zhong HN, Wang ZW, Yu WW, Hu CY. Chemical contaminants from food contact materials and articles made from or containing wood and bamboo - a review. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2023; 40:434-453. [PMID: 36693199 DOI: 10.1080/19440049.2023.2167003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Due to recently introduced 'so-called' bio- and plant-based friendly food contact materials and articles (FCM/FCA), some neglected safety issues need to be raised. In this review, potential chemical contaminants from FCM/FCA made from or containing wood and bamboo are presented. Sources, migration, and analytical issues in determining contaminants including intentionally and non-intentionally added substances (IAS and NIAS, respectively) are reviewed. Most of the contaminants are components from melamine-formaldehyde-resin (MFR), paints and coatings, preservatives, and bleaching agents. Tableware made of MFR containing bamboo fibres as a filler are not always suitable for use as tableware since harmful amounts of melamine and formaldehyde can migrate from the tableware into food and even accelerate the degradation of certain polymers with which they are mixed. In addition, in the EU bamboo in plastic FCM is not authorized under Regulation (EU) 10/2011. Paints and coatings used to provide surface coverage for bamboo and wooden articles also pose a risk of migration of heavy metals. Limits on preservatives in wood FCM are covered by legislation in many countries, nevertheless their contamination should not be ignored. Some wood species are considered 'toxic' or contain 'toxic' constituents that should not be used in contact with food, which are worth considering for legislation. IAS analyses in bamboo and wooden FCM is generally not a problem, but has proven to be more challenging for NIAS. Due to a complex mixture of substances contained in plant-based materials, there is a need to improve databases for non-target screening of such chemicals.
Collapse
Affiliation(s)
- Mu-Ying Guan
- Department of Food Science & Engineering, Jinan University, Guangzhou City, China
| | - Huai-Ning Zhong
- National Reference Laboratory for Food Contact Material (Guangdong), Guangzhou Customs Technology Center, Guangzhou City, China
| | - Zhi-Wei Wang
- Packing Engineering Institute, Jinan University, Zhuhai, China
| | - Wen-Wen Yu
- Department of Food Science & Engineering, Jinan University, Guangzhou City, China
| | - Chang-Ying Hu
- Department of Food Science & Engineering, Jinan University, Guangzhou City, China
| |
Collapse
|
2
|
Online coupling of matrix solid-phase dispersion to direct analysis in real time mass spectrometry for high-throughput analysis of regulated chemicals in consumer products. Anal Chim Acta 2023; 1239:340677. [PMID: 36628757 DOI: 10.1016/j.aca.2022.340677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2022] [Revised: 11/23/2022] [Accepted: 11/24/2022] [Indexed: 11/27/2022]
Abstract
The current work is the first study on online coupling of matrix solid-phase dispersion (MSPD) to direct analysis in real time mass spectrometry (DART-MS) bridging with solid-phase analytical derivatization (SPAD) based on a graphene oxide nanosheets (GONs)-coated cotton swab. Proof-of-concept demonstrations were explored for high-throughput analysis of a diversity of regulated chemicals in consumer products such as textiles, toys, and cosmetics. On-demand sorbent combinations were blended with samples, packed into MSPD columns, and mounted on a homemade 3D-printed rack module for automated sample feeding. To achieve good synergy between MSPD and DART-MS, a cotton swab with a conical tip deposited with GONs was attached to the bottom of the MSPD column. The swabs serve as a solid-phase microextraction probe for convenient enrichment of the eluted analytes from MSPD, thermal desorption of the enriched analytes by DART, and sensitive detection by a hybrid quadrupole-Orbitrap mass spectrometer. Furthermore, the utility of an on-swab SPAD strategy was demonstrated for the detection of formaldehyde by use of the derivatizing reagent of dansyl hydrazine, contributing to improved ionization efficiency without compromising the overall coherence of the analytical workflow. The MSPD-DART-MS methodology was systematically optimized and validated, obtaining acceptable recovery (71.7-110.3%), repeatability (11.8-19.3%), and sensitivity (limits of detection and quantitation in the ranges of 6.2-19.5 and 23.7-75.9 μg/kg) for 32 target analytes. The developed protocol streamlined sample extraction, clean-up, desorption, ionization, and detection, highlighting the appealing potential for high-throughput analysis of samples with complex matrices.
Collapse
|
3
|
Yue H, He F, Zhao Z, Duan Y. Plasma-based ambient mass spectrometry: Recent progress and applications. MASS SPECTROMETRY REVIEWS 2023; 42:95-130. [PMID: 34128567 DOI: 10.1002/mas.21712] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Revised: 05/28/2020] [Accepted: 06/02/2020] [Indexed: 06/12/2023]
Abstract
Ambient mass spectrometry (AMS) has grown as a group of advanced analytical techniques that allow for the direct sampling and ionization of the analytes in different statuses from their native environment without or with minimum sample pretreatments. As a significant category of AMS, plasma-based AMS has gained a lot of attention due to its features that allow rapid, real-time, high-throughput, in vivo, and in situ analysis in various fields, including bioanalysis, pharmaceuticals, forensics, food safety, and mass spectrometry imaging. Tens of new methods have been developed since the introduction of the first plasma-based AMS technique direct analysis in real-time. This review first provides a comprehensive overview of the established plasma-based AMS techniques from their ion source configurations, mechanisms, and developments. Then, the progress of the representative applications in various scientific fields in the past 4 years (January 2017 to January 2021) has been summarized. Finally, we discuss the current challenges and propose the future directions of plasma-based AMS from our perspective.
Collapse
Affiliation(s)
- Hanlu Yue
- College of Life Sciences, Sichuan University, Chengdu, China
| | - Feiyao He
- College of Life Sciences, Sichuan University, Chengdu, China
| | - Zhongjun Zhao
- School of Chemical Engineering, Sichuan University, Chengdu, China
| | - Yixiang Duan
- College of Life Sciences, Sichuan University, Chengdu, China
- School of Manufacturing Science and Engineering, Sichuan University, Chengdu, China
| |
Collapse
|
4
|
Shi L, Habib A, Bi L, Hong H, Begum R, Wen L. Ambient Ionization Mass Spectrometry: Application and Prospective. Crit Rev Anal Chem 2022; 54:1584-1633. [PMID: 36206159 DOI: 10.1080/10408347.2022.2124840] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/10/2022]
Abstract
Mass spectrometry (MS) is a formidable analytical tool for the analysis of non-polar to polar compounds individually and/or from mixtures, providing information on the molecular weights and chemical structures of the analytes. During the last more than one-decade, ambient ionization mass spectrometry (AIMS) has developed quickly, producing a wide range of platforms and proving scientific improvements in a variety of domains, from biological imaging to quick quality control. These methods have made it possible to detect target analytes in real time without sample preparation in an open environment, and they can be connected to any MS system with an atmospheric pressure interface. They also have the ability to analyze explosives, illicit drugs, disease diagnostics, drugs in biological samples, adulterants in food and agricultural products, reaction progress, and environmental monitoring. The development of novel ambient ionization techniques, such as probe electrospray ionization, paper spray ionization, and fiber spray ionization, employed even at picolitre to femtolitre solution levels to provide femtogram to attogram levels of the target analytes. The special characteristic of this ambient ion source, which has been extensively used, is the noninvasive property of PESI of examination of biological real samples. The results in the current review supports the idea that AIMS has emerged as a pioneer in MS-based approaches and that methods will continue to be developed along with improvements to existing ones in the near future.
Collapse
Affiliation(s)
- Lulu Shi
- Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai, China
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
| | - Ahsan Habib
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, Zhejiang, China
- Department of Chemistry, University of Dhaka, Dhaka, Bangladesh
| | - Lei Bi
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, Zhejiang, China
| | - Huanhuan Hong
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, Zhejiang, China
| | - Rockshana Begum
- Department of Chemistry, Shahjalal University of Science and Technology, Sylhet, Bangladesh
| | - Luhong Wen
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, Zhejiang, China
| |
Collapse
|
5
|
Chen M, Li M, Zhang W, Bai H, Ma Q. Natural Deep Eutectic Solvent-Based Dispersive Liquid-Liquid Microextraction Coupled with Direct Analysis in Real Time Mass Spectrometry: A Green Temperature-Mediated Analytical Strategy. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2022; 70:10919-10928. [PMID: 36000560 DOI: 10.1021/acs.jafc.2c03561] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Green analytical chemistry (GAC) represents a rapidly growing research field that aims at developing novel analytical approaches with minimal consumption of hazardous reagents and solvents. The current study reports on a GAC methodology exploiting the unique physicochemical properties of natural deep eutectic solvents (NADESs), a supposedly environmentally friendly class of solvents. Based on a temperature-mediated strategy, the NADESs were manipulated to undergo multiple phase transitions for favorable functionality and performance. As proof-of-concept demonstrations, both hydrophobic and hydrophilic NADESs were prepared for the extraction and analysis of eight phthalate esters in aqueous samples (food simulants) and three aflatoxins in oily samples (edible oils), respectively. NADES-based dispersive liquid-liquid microextraction (DLLME) was employed to achieve high-efficiency sample pretreatment. Afterward, the NADESs were transformed from liquids into solids by tuning the peripheral temperature for a convenient phase separation from the sample matrices. The solidified NADES extracts were melted and vaporized at elevated temperatures by transmission-mode direct analysis in real time (DART) for further quadrupole-Orbitrap high-resolution mass spectrometry (Q-Orbitrap HRMS) analysis. The developed protocol was validated, achieving good repeatability with relative standard deviations (RSDs) of less than 9% and satisfactory sensitivity with limits of detection (LODs) and quantitation (LOQs) ranging from 0.1 to 0.8 and 0.2 to 2.0 μg/kg, respectively. The greenness of the analytical methodology was assessed with the calculated scores of 0.66 and 0.57 for the hydrophobic and hydrophilic NADES-based protocols, respectively. The method was applied to marketed samples, highlighting the great potential for green chemical analysis.
Collapse
Affiliation(s)
- Meng Chen
- Key Laboratory of Consumer Product Quality Safety Inspection and Risk Assessment for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Ming Li
- School of Electrical and Control Engineering, North China University of Technology, Beijing 100144, China
| | - Wenxi Zhang
- Shaanxi Product Quality Supervision and Inspection Institute, Xi'an 710048, China
| | - Hua Bai
- Key Laboratory of Consumer Product Quality Safety Inspection and Risk Assessment for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Qiang Ma
- Key Laboratory of Consumer Product Quality Safety Inspection and Risk Assessment for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| |
Collapse
|
6
|
Rankin‐Turner S, Heaney LM. Applications of ambient ionization mass spectrometry in 2020: An annual review. ANALYTICAL SCIENCE ADVANCES 2021; 2:193-212. [PMID: 38716454 PMCID: PMC10989608 DOI: 10.1002/ansa.202000135] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 01/22/2021] [Accepted: 01/25/2021] [Indexed: 06/26/2024]
Abstract
Recent developments in mass spectrometry (MS) analyses have seen a concerted effort to reduce the complexity of analytical workflows through the simplification (or removal) of sample preparation and the shortening of run-to-run analysis times. Ambient ionization mass spectrometry (AIMS) is an exemplar MS-based technology that has swiftly developed into a popular and powerful tool in analytical science. This increase in interest and demonstrable applications is down to its capacity to enable the rapid analysis of a diverse range of samples, typically in their native state or following a minimalistic sample preparation approach. The field of AIMS is constantly improving and expanding, with developments of powerful and novel techniques, improvements to existing instrumentation, and exciting new applications added with each year that passes. This annual review provides an overview of applications of AIMS techniques over the past year (2020), with a particular focus on the application of AIMS in a number of key fields of research including biomedical sciences, forensics and security, food sciences, the environment, and chemical synthesis. Novel ambient ionization techniques are introduced, including picolitre pressure-probe electrospray ionization and fiber spray ionization, in addition to modifications and improvements to existing techniques such as hand-held devices for ease of use, and USB-powered ion sources for on-site analysis. In all, the information provided in this review supports the view that AIMS has become a leading approach in MS-based analyses and that improvements to existing methods, alongside the development of novel approaches, will continue across the foreseeable future.
Collapse
Affiliation(s)
- Stephanie Rankin‐Turner
- W. Harry Feinstone Department of Molecular Microbiology and Immunology, Johns Hopkins Bloomberg School of Public HealthJohns Hopkins UniversityBaltimoreMarylandUSA
| | - Liam M. Heaney
- School of Sport, Exercise and Health SciencesLoughborough UniversityLoughboroughLeicestershireUK
| |
Collapse
|
7
|
Zhang X, Ren X, Chingin K. Applications of direct analysis in real time mass spectrometry in food analysis: A review. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35:e9013. [PMID: 33277776 DOI: 10.1002/rcm.9013] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Revised: 10/16/2020] [Accepted: 11/22/2020] [Indexed: 06/12/2023]
Abstract
RATIONALE Direct analysis in real time (DART) combined with mass spectrometry (MS) detection has become one of the most broadly used analytical approaches for the direct molecular characterization of food samples with regard to their chemical quality, safety, origin, and authentication. The major advantages of DART-MS for food analysis include high chemical sensitivity and specificity, high speed and throughput of analysis, simplicity, and the obviation of tedious sample preparation and solvents. METHODS The recent applications of DART coupled with different mass analyzers, including quadrupole, ion trap, Orbitrap, and time of flight, are discussed. In addition, sample pretreatment methods that have been coupled with DART-MS are discussed. RESULTS We summarize the applications of DART-MS in food science and industry published in the period from 2005 to this date. The applications and analytical characteristics are systematically categorized across the three major types of foods: solid foods, liquid foods, and viscous foods. CONCLUSIONS DART-MS has proved its high suitability for the direct, rapid, and high-throughput molecular analysis of very different food samples with minimal or no sample preparation, thus offering a high-speed alternative to liquid chromatography/mass spectrometry (LC/MS) and gas chromatography/mass spectrometry (GC/MS) approaches that are traditionally employed in food analysis.
Collapse
Affiliation(s)
- Xiaoping Zhang
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang, China
| | - Xiang Ren
- State Key Laboratory of Inorganic Synthesis and Preparative Chemistry, College of Chemistry, Jilin University, Changchun, China
| | - Konstantin Chingin
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang, China
| |
Collapse
|