1
|
Besis A, Margaritis D, Samara C, Bekiaris E. Volatile Organic Compounds on Rhodes Island, Greece: Implications for Outdoor and Indoor Human Exposure. TOXICS 2024; 12:486. [PMID: 39058138 DOI: 10.3390/toxics12070486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2024] [Revised: 06/13/2024] [Accepted: 06/20/2024] [Indexed: 07/28/2024]
Abstract
Volatile organic compounds (VOC) are considered a class of pollutants with a significant presence in indoor and outdoor air and serious health effects. The aim of this study was to measure and evaluate the levels of outdoor and indoor VOCs at selected sites on Rhodes Island, Greece, during the cold and warm periods of 2023. Spatial and seasonal variations were evaluated; moreover, cancer and non-cancer inhalation risks were assessed. For this purpose, simultaneous indoor-outdoor air sampling was carried out on the island of Rhodes. VOCs were determined by Thermal Desorption-Gas Chromatography/Mass Spectroscopy (TD-GC/MS). Fifty-six VOCs with frequencies ≥ 50% were further considered. VOC concentrations (∑56VOCs) at all sites were found to be higher in the warm period. In the warm and cold sampling periods, the highest concentrations were found at the port of Rhodes City, while total VOC concentrations were dominated by alkanes. The Positive Matrix Factorization (PMF) model was applied to identify the VOC emission sources. Non-cancer and cancer risks for adults were within the safe levels.
Collapse
Affiliation(s)
- Athanasios Besis
- Centre for Research and Technology Hellas (CERTH)/Hellenic Institute of Transport (HIT), GR-57001 Thessaloniki, Greece
- Environmental Pollution Control Laboratory, Department of Chemistry, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece
| | - Dimitrios Margaritis
- Centre for Research and Technology Hellas (CERTH)/Hellenic Institute of Transport (HIT), GR-57001 Thessaloniki, Greece
| | - Constantini Samara
- Environmental Pollution Control Laboratory, Department of Chemistry, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece
| | - Evangelos Bekiaris
- Centre for Research and Technology Hellas (CERTH)/Hellenic Institute of Transport (HIT), GR-57001 Thessaloniki, Greece
| |
Collapse
|
2
|
You B, Zhou W, Li J, Li Z, Sun Y. A review of indoor Gaseous organic compounds and human chemical Exposure: Insights from Real-time measurements. ENVIRONMENT INTERNATIONAL 2022; 170:107611. [PMID: 36335895 DOI: 10.1016/j.envint.2022.107611] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Revised: 10/29/2022] [Accepted: 10/31/2022] [Indexed: 06/16/2023]
Abstract
Gaseous organic compounds, mainly volatile organic compounds (VOCs), have become a wide concern in various indoor environments where we spend the majority of our daily time. The sources, compositions, variations, and sinks of indoor VOCs are extremely complex, and their potential impacts on human health are less understood. Owing to the deployment of the state-of-the-art real-time mass spectrometry during the last two decades, our understanding of the sources, dynamic changes and chemical transformations of VOCs indoors has been significantly improved. This review aims to summarize the key findings from mass spectrometry measurements in recent indoor studies including residence, classroom, office, sports center, etc. The sources and sinks, compositions and distributions of indoor VOCs, and the factors (e.g., human activities, air exchange rate, temperature and humidity) driving the changes in indoor VOCs are discussed. The physical and chemical processes of gas-particle partitioning and secondary oxidation processes of VOCs, and their impacts on human health are summarized. Finally, the recommendations for future research directions on indoor VOCs measurements and indoor chemistry are proposed.
Collapse
Affiliation(s)
- Bo You
- State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China; College of Earth and Planetary Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Wei Zhou
- State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China
| | - Junyao Li
- State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China; College of Earth and Planetary Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Zhijie Li
- State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China; College of Earth and Planetary Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yele Sun
- State Key Laboratory of Atmospheric Boundary Layer Physics and Atmospheric Chemistry, Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100029, China; College of Earth and Planetary Sciences, University of Chinese Academy of Sciences, Beijing 100049, China.
| |
Collapse
|
3
|
Stinson B, Laguerre A, Gall ET. Per-Person and Whole-Building VOC Emission Factors in an Occupied School with Gas-Phase Air Cleaning. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:3354-3364. [PMID: 35130699 DOI: 10.1021/acs.est.1c06767] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Using real-time measurements of CO2 and volatile organic compounds (VOCs) in the air handler of an occupied middle school, we quantified source strengths for 249 VOCs and apportioned the source to the building, occupants and their activities, outdoor air, or recirculation air. For VOCs quantified in this study, there is a source to the outdoors of 8.6 ± 1.8 g/h in building exhaust air, of which 5.9 ± 1.7 g/h can be attributed to indoor sources (the building and occupants and their activities). The corresponding whole-building area emission factor from indoor sources is 1020 ± 300 μg/(m2 h), including reactive VOCs like isoprene and monoterpenes (33 ± 5.1 and 29 ± 5.7 μg/(m2 h), respectively). Per-person emission factors are calculated for compounds associated with occupants and their activities, e.g., monoterpenes are emitted at a rate of 280 ± 80 μg/(person h). The air handler included carbon scrubbing, reducing supply air concentrations of 125 compounds by 38 ± 19% (mean ± std. dev.) with a net removal of 2.4 ± 0.4 g/h of organic compounds from the building. This carbon scrubber reduces steady-state indoor concentrations of organics by 65 μg/m3 and the contribution of indoor sources of VOCs to the outdoor environment by ∼40%. These data inform the design and operation of buildings to reduce human exposure to VOCs inside buildings. These data indicate the potential for gas-phase air cleaning to improve both indoor air quality and reduce VOC emissions from buildings to the outdoor environment.
Collapse
Affiliation(s)
- Brett Stinson
- Department of Mechanical and Materials Engineering, Portland State University, 1930 Southwest 4th Avenue, Suite 400, Portland, Oregon 97201, United States
| | - Aurélie Laguerre
- Department of Mechanical and Materials Engineering, Portland State University, 1930 Southwest 4th Avenue, Suite 400, Portland, Oregon 97201, United States
| | - Elliott T Gall
- Department of Mechanical and Materials Engineering, Portland State University, 1930 Southwest 4th Avenue, Suite 400, Portland, Oregon 97201, United States
| |
Collapse
|
4
|
Gall ET, Mishra AK, Li J, Schiavon S, Laguerre A. Impact of Cognitive Tasks on CO 2 and Isoprene Emissions from Humans. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:139-148. [PMID: 33301299 DOI: 10.1021/acs.est.0c03850] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The human body emits a wide range of chemicals, including CO2 and isoprene. To examine the impact of cognitive tasks on human emission rates of CO2 and isoprene, we conducted an across-subject, counterbalanced study in a controlled chamber involving 16 adults. The chamber replicated an office environment. In groups of four, participants engaged in 30 min each of cognitive tasks (stressed activity) and watching nature documentaries (relaxed activity). Measured biomarkers indicated higher stress levels were achieved during the stressed activity. Per-person CO2 emission rates were greater for stressed than relaxed activity (30.3 ± 2.1 vs 27.0 ± 1.7 g/h/p, p = 0.0044, mean ± standard deviation). Isoprene emission rates were also elevated under stressed versus relaxed activity (154 ± 25 μg/h/p vs 116 ± 20 μg/h/p, p = 0.041). The chamber temperature was held constant at 26.2 ± 0.49 °C; incidental variation in temperature did not explain the variance in emission rates. Isoprene emission rates increased linearly with salivary α-amylase levels (r2 = 0.6, p = 0.02). These results imply the possibility of considering cognitive tasks when determining building ventilation rates. They also present the possibility of monitoring indicators of cognitive tasks of occupants through measurement of air quality.
Collapse
Affiliation(s)
- Elliott T Gall
- Department of Mechanical and Materials Engineering, Portland State University, Portland, Oregon 97201, United States
| | - Asit Kumar Mishra
- Berkeley Education Alliance for Research in Singapore, Singapore 138602
| | - Jiayu Li
- Berkeley Education Alliance for Research in Singapore, Singapore 138602
| | - Stefano Schiavon
- Center for the Built Environment, University of California, Berkeley, California 94720-2284, United States
| | - Aurélie Laguerre
- Department of Mechanical and Materials Engineering, Portland State University, Portland, Oregon 97201, United States
| |
Collapse
|
5
|
Evaluating Volatile Organic Compound Emissions from Cross-Laminated Timber Bonded with a Soy-Based Adhesive. BUILDINGS 2020. [DOI: 10.3390/buildings10110191] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Volatile organic compound (VOC) emissions from indoor sources are large determinants of the indoor air quality (IAQ) and occupant health. Cross-laminated timber (CLT) is a panelized engineered wood product often left exposed as an interior surface finish. As a certified structural building product, CLT is currently exempt from meeting VOC emission limits for composite wood products and confirming emissions through California Department of Public Health (CDPH) Standard Method testing. In this study, small chamber testing was conducted to evaluate VOC emissions from three laboratory-produced CLT samples: One bonded with a new soy-based cold-set adhesive; a second bonded with a commercially available polyurethane (PUR) adhesive; and the third assembled without adhesive using dowels. A fourth commercially-produced eight-month-old sample bonded with melamine formaldehyde (MF) adhesive was also tested. All four samples were produced with Douglas-fir. The test results for the three laboratory-produced samples demonstrated VOC emissions compliance with the reference standard. The commercially-produced and aged CLT sample bonded with MF adhesive did not meet the acceptance criterion for formaldehyde of ≤9.0 µg/m3. The estimated indoor air concentration of formaldehyde in an office with the MF sample was 54.4 µg/m3; the results for the soy, PUR, and dowel samples were all at or below 2.5 µg/m3.
Collapse
|
6
|
Wolkoff P. Indoor air chemistry: Terpene reaction products and airway effects. Int J Hyg Environ Health 2020; 225:113439. [PMID: 32044535 DOI: 10.1016/j.ijheh.2019.113439] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Revised: 12/04/2019] [Accepted: 12/18/2019] [Indexed: 12/15/2022]
Abstract
Reactive chemistry is ubiquitous indoors with a wealth of complex oxidation reactions; some of these are initiated by both homogeneous and heterogeneous reaction of ozone with unsaturated organic compounds and subsequent the hydroxyl radical, either in the gas-phase or on reactive surfaces. One major focus has been the reaction of common and abundant terpene-based fragrances in indoor air emitted from many wood-based materials, a variety of consumer products, and citrus fruits and flowers. Inhalation of the terpenes themselves are generally not considered a health concern (both acute and long-term) due to their low indoor air concentrations; however, their gas- and surface reactions with ozone and the hydroxyl radical produce a host of products, both gaseous, i. a. formaldehyde, and ultrafine particles formed by condensation/nucleation processes. These reaction products may be of health concern. Human cell bioassays with key reaction products from ozone-initiated terpene reactions have shown some inflammatory reactions, but results are difficult to interpret for human exposure and risk assessment. Acute effects like sensory irritation in eyes and airways are unlikely or present at very low intensity in real life conditions based on rodent and human exposure studies and known thresholds for sensory irritation in eyes and airways and derived human reference values for airflow limitation and pulmonary irritation. Some fragrances and their ozone-initiated reaction products may possess anti-inflammatory properties. However, long-term effects of the reaction products as ultrafine particles are poorly explored. Material and product surfaces with high ozone deposition velocities may significantly impact the perceived air quality by altered emissions from both homogeneous and heterogeneous surface reactions.
Collapse
Affiliation(s)
- Peder Wolkoff
- National Research Centre for the Working Environment, NRCWE, Lersø Parkallé 105, 2920, Copenhagen, Denmark.
| |
Collapse
|
7
|
Monitored Indoor Environmental Quality of a Mass Timber Office Building: A Case Study. BUILDINGS 2019. [DOI: 10.3390/buildings9060142] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
A broad range of building performance monitoring, sampling, and evaluation was conducted periodically after construction and spanning more than a year, for an occupied office building constructed using mass timber elements such as cross-laminated timber (CLT) floor and roof panels, as well as glue-laminated timber (GLT) beams and columns. This case study contributes research on monitoring indoor environmental quality in buildings, describing one of the few studies of an occupied mass timber building, and analyzing data in three areas that impact occupant experience: indoor air quality, bacterial community composition, and floor vibration. As a whole, the building was found to perform well. Volatile organic compounds (VOCs), including formaldehyde, were analyzed using multiple methods. Formaldehyde was found to be present in the building, though levels were below most recommended exposure limits. The source of formaldehyde was not able to be identified in this study. The richness of the bacterial community was affected by the height of sampling with respect to the floor, and richness and composition was affected by the location within the building. Floor vibration was observed to be below recognized human comfort thresholds.
Collapse
|