1
|
Ugodnikov A, Persson H, Simmons CA. Bridging barriers: advances and challenges in modeling biological barriers and measuring barrier integrity in organ-on-chip systems. LAB ON A CHIP 2024; 24:3199-3225. [PMID: 38689569 DOI: 10.1039/d3lc01027a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2024]
Abstract
Biological barriers such as the blood-brain barrier, skin, and intestinal mucosal barrier play key roles in homeostasis, disease physiology, and drug delivery - as such, it is important to create representative in vitro models to improve understanding of barrier biology and serve as tools for therapeutic development. Microfluidic cell culture and organ-on-a-chip (OOC) systems enable barrier modelling with greater physiological fidelity than conventional platforms by mimicking key environmental aspects such as fluid shear, accurate microscale dimensions, mechanical cues, extracellular matrix, and geometrically defined co-culture. As the prevalence of barrier-on-chip models increases, so does the importance of tools that can accurately assess barrier integrity and function without disturbing the carefully engineered microenvironment. In this review, we first provide a background on biological barriers and the physiological features that are emulated through in vitro barrier models. Then, we outline molecular permeability and electrical sensing barrier integrity assessment methods, and the related challenges specific to barrier-on-chip implementation. Finally, we discuss future directions in the field, as well important priorities to consider such as fabrication costs, standardization, and bridging gaps between disciplines and stakeholders.
Collapse
Affiliation(s)
- Alisa Ugodnikov
- Translational Biology & Engineering Program, Ted Rogers Centre for Heart Research, Toronto, ON M5G 1M1, Canada.
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9, Canada
| | - Henrik Persson
- Translational Biology & Engineering Program, Ted Rogers Centre for Heart Research, Toronto, ON M5G 1M1, Canada.
| | - Craig A Simmons
- Translational Biology & Engineering Program, Ted Rogers Centre for Heart Research, Toronto, ON M5G 1M1, Canada.
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9, Canada
- Department of Mechanical & Industrial Engineering, University of Toronto, Toronto, ON M5S 3G8, Canada
| |
Collapse
|
2
|
Liu X, Zhang X, Feng R, Ren X, Wu D, Liu X, Liu L, Wei Q. Microfluidic Immunosensor Platform for Sensitive Detection of Human Epidermal Growth Factor Receptor-2 Based on Enhanced Cathode Electrochemiluminescence of Bimetallic Nanoclusters. Anal Chem 2024; 96:8390-8398. [PMID: 38716680 DOI: 10.1021/acs.analchem.3c05561] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/29/2024]
Abstract
In this work, a microfluidic immunosensor chip was developed by incorporating microfluidic technology with electrochemiluminescence (ECL) for sensitive detection of human epidermal growth factor receptor-2 (HER2). The immunosensor chip can achieve robust reproducibility in mass production by integrating multiple detection units in a series. Notably, nanoscale materials can be better adapted to microfluidic systems, greatly enhancing the accuracy of the immunosensor chip. Ag@Au NCs closed by glutathione (GSH) were introduced in the ECL microfluidic immunosensor system with excellent and stable ECL performance. The synthesized CeO2-Au was applied as a coreaction promoter in the ECL signal amplification system, which made the result of HER2 detection more reliable. In addition, the designed microfluidic immunosensor chip integrated the biosensing system into a microchip, realizing rapid and accurate detection of HER2 by its high throughput and low usage. The developed short peptide ligand NARKFKG (NRK) achieved an effective connection between the antibody and nanocarrier for improving the detection efficiency of the sensor. The immunosensor chip had better storage stability and sensitivity than traditional detection methods, with a wide detection range from 10 fg·mL-1 to 100 ng·mL-1 and a low detection limit (LOD) of 3.29 fg·mL-1. In general, a microfluidic immunosensor platform was successfully constructed, providing a new idea for breast cancer (BC) clinical detection.
Collapse
Affiliation(s)
- Xuening Liu
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Xiaoyue Zhang
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Rui Feng
- School of Water Conservancy and Environment, University of Jinan, Jinan 250022, China
| | - Xiang Ren
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Dan Wu
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Xuejing Liu
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Lei Liu
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Qin Wei
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
- Department of Chemistry, Sungkyunkwan University, Suwon 16419, Republic of Korea
| |
Collapse
|
3
|
Bezinge L, Shih CJ, Richards DA, deMello AJ. Electrochemical Paper-Based Microfluidics: Harnessing Capillary Flow for Advanced Diagnostics. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024:e2401148. [PMID: 38801400 DOI: 10.1002/smll.202401148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 04/29/2024] [Indexed: 05/29/2024]
Abstract
Electrochemical paper-based microfluidics has attracted much attention due to the promise of transforming point-of-care diagnostics by facilitating quantitative analysis with low-cost and portable analyzers. Such devices harness capillary flow to transport samples and reagents, enabling bioassays to be executed passively. Despite exciting demonstrations of capillary-driven electrochemical tests, conventional methods for fabricating electrodes on paper impede capillary flow, limit fluidic pathways, and constrain accessible device architectures. This account reviews recent developments in paper-based electroanalytical devices and offers perspective by revisiting key milestones in lateral flow tests and paper-based microfluidics engineering. The study highlights the benefits associated with electrochemical sensing and discusses how the detection modality can be leveraged to unlock novel functionalities. Particular focus is given to electrofluidic platforms that embed electrodes into paper for enhanced biosensing applications. Together, these innovations pave the way for diagnostic technologies that offer portability, quantitative analysis, and seamless integration with digital healthcare, all without compromising the simplicity of commercially available rapid diagnostic tests.
Collapse
Affiliation(s)
- Léonard Bezinge
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| | - Chih-Jen Shih
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| | - Daniel A Richards
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| | - Andrew J deMello
- Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, ETH Zürich, Vladimir-Prelog-Weg 1, Zürich, 8093, Switzerland
| |
Collapse
|
4
|
Bocu R. Extended Review Concerning the Integration of Electrochemical Biosensors into Modern IoT and Wearable Devices. BIOSENSORS 2024; 14:214. [PMID: 38785688 PMCID: PMC11117989 DOI: 10.3390/bios14050214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Revised: 04/17/2024] [Accepted: 04/23/2024] [Indexed: 05/25/2024]
Abstract
Electrochemical biosensors include a recognition component and an electronic transducer, which detect the body fluids with a high degree of accuracy. More importantly, they generate timely readings of the related physiological parameters, and they are suitable for integration into portable, wearable and implantable devices that are significant relative to point-of-care diagnostics scenarios. As an example, the personal glucose meter fundamentally improves the management of diabetes in the comfort of the patients' homes. This review paper analyzes the principles of electrochemical biosensing and the structural features of electrochemical biosensors relative to the implementation of health monitoring and disease diagnostics strategies. The analysis particularly considers the integration of the biosensors into wearable, portable, and implantable systems. The fundamental aim of this paper is to present and critically evaluate the identified significant developments in the scope of electrochemical biosensing for preventive and customized point-of-care diagnostic devices. The paper also approaches the most important engineering challenges that should be addressed in order to improve the sensing accuracy, and enable multiplexing and one-step processes, which mediate the integration of electrochemical biosensing devices into digital healthcare scenarios.
Collapse
Affiliation(s)
- Razvan Bocu
- Department of Mathematics and Computer Science, Transilvania University of Brasov, 500036 Brasov, Romania
| |
Collapse
|
5
|
Singh R, Gupta R, Bansal D, Bhateria R, Sharma M. A Review on Recent Trends and Future Developments in Electrochemical Sensing. ACS OMEGA 2024; 9:7336-7356. [PMID: 38405479 PMCID: PMC10882602 DOI: 10.1021/acsomega.3c08060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Revised: 01/07/2024] [Accepted: 01/12/2024] [Indexed: 02/27/2024]
Abstract
Electrochemical methods and devices have ignited prodigious interest for sensing and monitoring. The greatest challenge for science is far from meeting the expectations of consumers. Electrodes made of two-dimensional (2D) materials such as graphene, metal-organic frameworks, MXene, and transition metal dichalcogenides as well as alternative electrochemical sensing methods offer potential to improve selectivity, sensitivity, detection limit, and response time. Moreover, these advancements have accelerated the development of wearable and point-of-care electrochemical sensors, opening new possibilities and pathways for their applications. This Review presents a critical discussion of the recent developments and trends in electrochemical sensing.
Collapse
Affiliation(s)
- Rimmy Singh
- Department of Applied Science & Humanities, DPG Institute of Technology and Management, Gurugram 122004, India
| | - Ruchi Gupta
- School of Chemistry, University of Birmingham, Birmingham B15 2TT, U.K
| | | | - Rachna Bhateria
- Department of Environmental Science, Maharshi Dayanand University, Rohtak 124001, India
| | - Mona Sharma
- Department of Environmental Studies, Central University of Haryana, Mahendergarh 123031, India
| |
Collapse
|
6
|
Jankelow A, Chen CL, Cowell TW, Espinosa de Los Monteros J, Bian Z, Kindratenko V, Koprowski K, Darsi S, Han HS, Valera E, Bashir R. Multiplexed electrical detection of whole viruses from plasma in a microfluidic platform. Analyst 2024; 149:1190-1201. [PMID: 38213181 DOI: 10.1039/d3an01510f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2024]
Abstract
The advancement of point-of-care diagnostics is crucial to improving patient outcomes, especially in areas with low access to hospitals or specialized laboratories. In particular, rapid, sensitive, and multiplexed detection of disease biomarkers has great potential to achieve accurate diagnosis and inform high quality care for patients. Our Coulter counting and immunocapture based detection system has previously shown its broad applicability in the detection of cells, proteins, and nucleic acids. This paper expands the capability of the platform by demonstrating multiplexed detection of whole-virus particles using electrically distinguishable hydrogel beads by demonstrating the capability of our platform to achieve simultaneous detection at clinically relevant concentrations of hepatitis A virus (>2 × 103 IU mL-1) and human parvovirus B19 virus like particles (>106 IU mL-1) from plasma samples. The expanded versatility of the differential electrical counting platform allows for more robust and diverse testing capabilities.
Collapse
Affiliation(s)
- Aaron Jankelow
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
- Nick Holonyak Jr Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
- Biomedical Research Center, Carle Foundation Hospital, Urbana, Illinois, USA
| | - Chih-Lin Chen
- Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Thomas W Cowell
- Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Javier Espinosa de Los Monteros
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
- Biomedical Research Center, Carle Foundation Hospital, Urbana, Illinois, USA
| | - Zheng Bian
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
- Nick Holonyak Jr Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Victoria Kindratenko
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
- Nick Holonyak Jr Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Katherine Koprowski
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
- Nick Holonyak Jr Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Sriya Darsi
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
- Nick Holonyak Jr Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Hee-Sun Han
- Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
- Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Enrique Valera
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
- Nick Holonyak Jr Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
- Biomedical Research Center, Carle Foundation Hospital, Urbana, Illinois, USA
- Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
| | - Rashid Bashir
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
- Nick Holonyak Jr Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
- Biomedical Research Center, Carle Foundation Hospital, Urbana, Illinois, USA
- Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA
- Department of Biomedical and Translation Science, Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
- Department of Materials Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| |
Collapse
|
7
|
Pawar D, Lo Presti D, Silvestri S, Schena E, Massaroni C. Current and future technologies for monitoring cultured meat: A review. Food Res Int 2023; 173:113464. [PMID: 37803787 DOI: 10.1016/j.foodres.2023.113464] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 08/30/2023] [Accepted: 09/10/2023] [Indexed: 10/08/2023]
Abstract
The high population growth rate, massive animal food consumption, fast economic progress, and limited food resources could lead to a food crisis in the future. There is a huge requirement for dietary proteins including cultured meat is being progressed to fulfill the need for meat-derived proteins in the diet. However, production of cultured meat requires monitoring numerous bioprocess parameters. This review presents a comprehensive overview of various widely adopted techniques (optical, spectroscopic, electrochemical, capacitive, FETs, resistive, microscopy, and ultrasound) for monitoring physical, chemical, and biological parameters that can improve the bioprocess control in cultured meat. The methods, operating principle, merits/demerits, and the main open challenges are reviewed with the aim to support the readers in advancing knowledge on novel sensing systems for cultured meat applications.
Collapse
Affiliation(s)
- Dnyandeo Pawar
- Microwave Materials Group, Centre for Materials for Electronics Technology (C-MET), Athani P.O, Thrissur, Kerala 680581, India.
| | - Daniela Lo Presti
- Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy
| | - Sergio Silvestri
- Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy
| | - Emiliano Schena
- Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy
| | - Carlo Massaroni
- Unit of Measurements and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy
| |
Collapse
|
8
|
Feng Y, Zhu J, Chai H, He W, Huang L, Wang W. Impedance-Based Multimodal Electrical-Mechanical Intrinsic Flow Cytometry. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2303416. [PMID: 37438542 DOI: 10.1002/smll.202303416] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Revised: 06/21/2023] [Indexed: 07/14/2023]
Abstract
Reflecting various physiological states and phenotypes of single cells, intrinsic biophysical characteristics (e.g., mechanical and electrical properties) are reliable and important, label-free biomarkers for characterizing single cells. However, single-modal mechanical or electrical properties alone are not specific enough to characterize single cells accurately, and it has been long and challenging to couple the conventionally image-based mechanical characterization and impedance-based electrical characterization. In this work, the spatial-temporal characteristics of impedance sensing signal are leveraged, and an impedance-based multimodal electrical-mechanical flow cytometry framework for on-the-fly high-dimensional intrinsic measurement is proposed, that is, Young's modulus E, fluidity β, radius r, cytoplasm conductivity σi , and specific membrane capacitance Csm , of single cells. With multimodal high-dimensional characterization, the electrical-mechanical flow cytometry can better reveal the difference in cell types, demonstrated by the experimental results with three types of cancer cells (HepG2, MCF-7, and MDA-MB-468) with 93.4% classification accuracy and pharmacological perturbations of the cytoskeleton (fixed and Cytochalasin B treated cells) with 95.1% classification accuracy. It is envisioned that multimodal electrical-mechanical flow cytometry provides a new perspective for accurate label-free single-cell intrinsic characterization.
Collapse
Affiliation(s)
- Yongxiang Feng
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, 100190, P. R. China
| | - Junwen Zhu
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, 100190, P. R. China
| | - Huichao Chai
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, 100190, P. R. China
| | - Weihua He
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, 100190, P. R. China
| | - Liang Huang
- Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Hefei University of Technology, Hefei, Anhui, 230002, P. R. China
| | - Wenhui Wang
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, 100190, P. R. China
| |
Collapse
|
9
|
Li Y, Chang CC, Wang C, Wu WT, Wang CM, Tu HL. Microfluidic Biosensor Decorated with an Indium Phosphate Nanointerface for Attomolar Dopamine Detection. ACS Sens 2023; 8:2263-2270. [PMID: 37155824 DOI: 10.1021/acssensors.3c00228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Developing functional materials that directly integrate into miniaturized devices for sensing applications is essential for constructing the next-generation point-of-care system. Although crystalline structure materials such as metal organic frameworks are attractive materials exhibiting promising potential for biosensing, their integration into miniaturized devices is limited. Dopamine (DA) is a major neurotransmitter released by dopaminergic neurons and has huge implications in neurodegenerative diseases. Integrated microfluidic biosensors capable of sensitive monitoring of DA from mass-limited samples is thus of significant importance. In this study, we developed and systematically characterized a microfluidic biosensor functionalized with the hybrid material composed of indium phosphate and polyaniline nanointerfaces for DA detection. Under the flowing operation, this biosensor displays a linear dynamic sensing range going from 10-18 to 10-11 M and a limit of detection (LOD) value of 1.83 × 10-19 M. In addition to the high sensitivity, this microfluidic sensor showed good selectivity toward DA and high stability (>1000 cycles). Further, the reliability and practical utility of the microfluidic biosensor were demonstrated using the neuro-2A cells treated with the activator, promoter, and inhibiter. These promising results underscore the importance and potential of microfluidic biosensors integrated with hybrid materials as advanced biosensors systems.
Collapse
Affiliation(s)
- Ying Li
- Institute of Chemistry, Academia Sinica, Taipei 11529, Taiwan
- Institute of Bioscience and Biotechnology, National Taiwan Ocean University, Keelung 20224, Taiwan
| | - Chiao-Chun Chang
- Institute of Chemistry, Academia Sinica, Taipei 11529, Taiwan
- Institute of Bioscience and Biotechnology, National Taiwan Ocean University, Keelung 20224, Taiwan
| | - Chu Wang
- Institute of Bioscience and Biotechnology, National Taiwan Ocean University, Keelung 20224, Taiwan
| | - Wen-Ti Wu
- Institute of Chemistry, Academia Sinica, Taipei 11529, Taiwan
| | - Chih-Min Wang
- Institute of Bioscience and Biotechnology, National Taiwan Ocean University, Keelung 20224, Taiwan
- General Education Center, National Taiwan Ocean University, Keelung 20224, Taiwan
| | - Hsiung-Lin Tu
- Institute of Chemistry, Academia Sinica, Taipei 11529, Taiwan
- Genome and Systems Biology Degree Program, Academia Sinica and National Taiwan University, Taipei 10617, Taiwan
| |
Collapse
|
10
|
Biswas GC, Khan MTM, Das J. Wearable nucleic acid testing platform - A perspective on rapid self-diagnosis and surveillance of infectious diseases. Biosens Bioelectron 2023; 226:115115. [PMID: 36746023 DOI: 10.1016/j.bios.2023.115115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 12/21/2022] [Accepted: 01/30/2023] [Indexed: 02/05/2023]
Abstract
Wearable biosensors (WB) are currently attracting considerable interest for rapid detection and monitoring of biomarkers including metabolites, protein, and pathogen in bodily fluids (e.g., sweat, saliva, tears, and interstitial fluid). Another branch of WB termed wearable nucleic acid testing (NAT) is blossoming thanks to the development of microfluidic technology and isothermal nucleic acid amplification technique (iNAAT); however, there are only few reports on this. The wearable NAT is an emerging field of point-of-care (POC) diagnostics, and holds the promise for time-saving self-diagnosis, and evidence-based surveillance of infectious diseases in remote or low-resource settings. The use of wearable NAT can also be advanced to include molecular diagnosis, the identification of cancer biomarkers, genetic abnormalities, and other aspects. The wearable NAT provides the potential for evidence-based surveillance of infectious diseases when combined with internet connectivity and App software. To make the wearable NAT accessible to the end users, however, improvements must be made to the fabrication, cost, speed, sensitivity, specificity, sampling, iNAAT, analyzer, and a few other features. So, in this paper, we looked at the wearable NAT's most recent development, identified its difficulties, and defined its potential for managing infectious diseases quickly in the future. This is the wearable NAT review's first effort. We expect that this article will provide the concise resources needed to develop and deploy an efficient wearable NAT system.
Collapse
Affiliation(s)
- Gokul Chandra Biswas
- Department of Genetic Engineering and Biotechnology, School of Life Sciences, Shahjalal University of Science and Technology, Sylhet, 3114, Bangladesh.
| | - Md Taufiqur Mannan Khan
- Department of Genetic Engineering and Biotechnology, School of Life Sciences, Shahjalal University of Science and Technology, Sylhet, 3114, Bangladesh
| | - Jagotamoy Das
- Department of Chemistry, Northwestern University, 2170 Campus Dr, Evanston, IL, 60208, USA.
| |
Collapse
|
11
|
Zhang W, Du J, Wang K, Li Y, Chen C, Yang L, Kan Z, Dong B, Wang L, Xu L. Integrated dual-channel electrochemical immunosensor for early diagnosis and monitoring of periodontitis by detecting multiple biomarkers in saliva. Anal Chim Acta 2023; 1247:340878. [PMID: 36781246 DOI: 10.1016/j.aca.2023.340878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2022] [Revised: 01/08/2023] [Accepted: 01/20/2023] [Indexed: 01/22/2023]
Abstract
Periodontitis, as the sixth prevalence chronic inflammation worldwide, has inconspicuous and often-overlooked symptoms at early stage, eventually leading to permanent damage to the teeth and supporting tissues. The timely and accurate diagnosis of periodontitis and monitoring its progress appear to be particularly important for clinical treatment. Herein, a dual-channel electrochemical immunosensor was developed for the synchronized detection of two periodontitis-related biomarkers in saliva: interleukin-1β (IL-1β) and matrix metalloproteinase-8 (MMP-8). Owing to its miniaturization, detachability, and portability, this sensor has the potential to detect multiple biomarkers in a point-of-care manner for the early diagnosis and monitoring of periodontitis. The nanocomposites consisted of iridium oxide nanotubes and two-dimensional MXene nanosheets enhance the electrochemical performance of the sensor, achieving excellent sensitivity with wide detection ranges of 0.1-100 and 1-200 ng mL-1, low limits of detection of 0.014 and 0.13 ng mL-1, and relatively high correlation coefficients of 0.9911 and 0.9990 for IL-1β and MMP-8, respectively. Furthermore, this device possesses excellent selectivity in complex samples without cross-talk, as well as high recovery and accuracy in spiked artificial saliva. Importantly, the dual-channel device achieves higher diagnostic accuracy for different stages of periodontitis when MMP-8 and IL-1β were simultaneously monitored within clinicopathological saliva. This work proposes a considerable potential for early diagnosis and severity distinguishment of periodontitis in a point-of-care manner, which would be beneficial for progression prediction, treatment guidance, and prognosis assessment of periodontitis.
Collapse
Affiliation(s)
- Wei Zhang
- Department of Oral Implantology, Jilin Provincial Key Laboratory of Sciences and Technology for Stomatology Nanoengineering School and Hospital of Stomatology, Jilin University, Changchun, 130021, China
| | - Juanrui Du
- Department of Oral Implantology, Jilin Provincial Key Laboratory of Sciences and Technology for Stomatology Nanoengineering School and Hospital of Stomatology, Jilin University, Changchun, 130021, China
| | - Kun Wang
- Department of Oral Implantology, Jilin Provincial Key Laboratory of Sciences and Technology for Stomatology Nanoengineering School and Hospital of Stomatology, Jilin University, Changchun, 130021, China
| | - Yige Li
- Department of Oral Implantology, Jilin Provincial Key Laboratory of Sciences and Technology for Stomatology Nanoengineering School and Hospital of Stomatology, Jilin University, Changchun, 130021, China
| | - Cong Chen
- Department of Oral Implantology, Jilin Provincial Key Laboratory of Sciences and Technology for Stomatology Nanoengineering School and Hospital of Stomatology, Jilin University, Changchun, 130021, China
| | - Long Yang
- State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130021, China
| | - Zitong Kan
- State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130021, China
| | - Biao Dong
- State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130021, China
| | - Lin Wang
- Department of Oral Implantology, Jilin Provincial Key Laboratory of Sciences and Technology for Stomatology Nanoengineering School and Hospital of Stomatology, Jilin University, Changchun, 130021, China.
| | - Lin Xu
- State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130021, China.
| |
Collapse
|
12
|
Asci Erkocyigit B, Ozufuklar O, Yardim A, Guler Celik E, Timur S. Biomarker Detection in Early Diagnosis of Cancer: Recent Achievements in Point-of-Care Devices Based on Paper Microfluidics. BIOSENSORS 2023; 13:387. [PMID: 36979600 PMCID: PMC10046104 DOI: 10.3390/bios13030387] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 03/03/2023] [Accepted: 03/08/2023] [Indexed: 06/18/2023]
Abstract
Microfluidics is very crucial in lab-on-a-chip systems for carrying out operations in a large-scale laboratory environment on a single chip. Microfluidic systems are miniaturized devices in which the fluid behavior and control can be manipulated on a small platform, with surface forces on the platform being greater than volumetric forces depending on the test method used. In recent years, paper-based microfluidic analytical devices (μPADs) have been developed to be used in point-of-care (POC) technologies. μPADs have numerous advantages, including ease of use, low cost, capillary action liquid transfer without the need for power, the ability to store reagents in active form in the fiber network, and the capability to perform multiple tests using various measurement techniques. These benefits are critical in the advancement of paper-based microfluidics in the fields of disease diagnosis, drug application, and environment and food safety. Cancer is one of the most critical diseases for early detection all around the world. Detecting cancer-specific biomarkers provides significant data for both early diagnosis and controlling the disease progression. μPADs for cancer biomarker detection hold great promise for improving cure rates, quality of life, and minimizing treatment costs. Although various types of bioanalytical platforms are available for the detection of cancer biomarkers, there are limited studies and critical reviews on paper-based microfluidic platforms in the literature. Hence, this article aims to draw attention to these gaps in the literature as well as the features that future platforms should have.
Collapse
Affiliation(s)
- Bilge Asci Erkocyigit
- Department of Biotechnology, Institute of Natural Sciences, Ege University, Izmir 35100, Turkey
| | - Ozge Ozufuklar
- Department of Biotechnology, Institute of Natural Sciences, Ege University, Izmir 35100, Turkey
| | - Aysenur Yardim
- Department of Bioengineering, Institute of Natural Sciences, Ege University, Izmir 35100, Turkey
| | - Emine Guler Celik
- Department of Bioengineering, Faculty of Engineering, Ege University, Izmir 35100, Turkey
| | - Suna Timur
- Department of Biochemistry, Faculty of Science, Ege University, Izmir 35100, Turkey
- Central Research Test and Analysis Laboratory Application, Research Center, Ege University, Izmir 35100, Turkey
| |
Collapse
|
13
|
Wu J, Liu H, Chen W, Ma B, Ju H. Device integration of electrochemical biosensors. NATURE REVIEWS BIOENGINEERING 2023; 1:346-360. [PMID: 37168735 PMCID: PMC9951169 DOI: 10.1038/s44222-023-00032-w] [Citation(s) in RCA: 57] [Impact Index Per Article: 57.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Accepted: 01/23/2023] [Indexed: 05/13/2023]
Abstract
Electrochemical biosensors incorporate a recognition element and an electronic transducer for the highly sensitive detection of analytes in body fluids. Importantly, they can provide rapid readouts and they can be integrated into portable, wearable and implantable devices for point-of-care diagnostics; for example, the personal glucose meter enables at-home assessment of blood glucose levels, greatly improving the management of diabetes. In this Review, we discuss the principles of electrochemical biosensing and the design of electrochemical biosensor devices for health monitoring and disease diagnostics, with a particular focus on device integration into wearable, portable and implantable systems. Finally, we outline the key engineering challenges that need to be addressed to improve sensing accuracy, enable multiplexing and one-step processes, and integrate electrochemical biosensing devices in digital health-care pathways.
Collapse
Affiliation(s)
- Jie Wu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, China
| | - Hong Liu
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, China
| | - Weiwei Chen
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, China
- School of Geographic and Biologic Information, Nanjing University of Posts and Telecommunications, Nanjing, China
| | - Biao Ma
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, China
| | - Huangxian Ju
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, China
| |
Collapse
|
14
|
Shrestha LK, Shrestha RG, Shahi S, Gnawali CL, Adhikari MP, Bhadra BN, Ariga K. Biomass Nanoarchitectonics for Supercapacitor Applications. J Oleo Sci 2023; 72:11-32. [PMID: 36624057 DOI: 10.5650/jos.ess22377] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
Nanoarchitectonics integrates nanotechnology with numerous scientific disciplines to create innovative and novel functional materials from nano-units (atoms, molecules, and nanomaterials). The objective of nanoarchitectonics concept is to develop functional materials and systems with rationally architected functional units. This paper explores the progress and potential of this field using biomass nanoarchitectonics for supercapacitor applications as examples of energetic materials and devices. Strategic design of nanoporous carbons that exhibit ultra-high surface area and hierarchically pore architectures comprising micro- and mesopore structure and controlled pore size distributions are of great significance in energy-related applications, including in high-performance supercapacitors, lithium-ion batteries, and fuel cells. Agricultural wastes or natural biomass are lignocellulosic materials and are excellent carbon sources for the preparation of hierarchically porous carbons with an ultra-high surface area that are attractive materials in high-performance supercapacitor applications due to high electrical and ion conduction, extreme porosity, and exceptional chemical and thermal stability. In this review, we will focus on the latest advancements in the fabrication of hierarchical porous carbon materials from different biomass by chemical activation method. Particularly, the importance of biomass-derived ultra-high surface area porous carbons, hierarchical architectures with interconnected pores in high-energy storage, and high-performance supercapacitors applications will be discussed. Finally, the current challenges and outlook for the further improvement of carbon materials derived from biomass or agricultural wastes in the advancements of supercapacitor devices will be discussed.
Collapse
Affiliation(s)
- Lok Kumar Shrestha
- International Center for Materials Nanoarchitectonics (WPI-MANA), National Institute for Materials Science (NIMS).,Department of Materials Science, Faculty of Pure and Applied Sciences, University of Tsukuba
| | - Rekha Goswami Shrestha
- International Center for Materials Nanoarchitectonics (WPI-MANA), National Institute for Materials Science (NIMS)
| | - Sabina Shahi
- Central Department of Chemistry, Tribhuvan University
| | - Chhabi Lal Gnawali
- Department of Applied Sciences and Chemical Engineering, Pulchowk Campus, Institute of Engineering (IOE), Tribhuvan University (TU)
| | | | - Biswa Nath Bhadra
- International Center for Materials Nanoarchitectonics (WPI-MANA), National Institute for Materials Science (NIMS)
| | - Katsuhiko Ariga
- International Center for Materials Nanoarchitectonics (WPI-MANA), National Institute for Materials Science (NIMS).,Graduate School of Frontier Sciences, The University of Tokyo
| |
Collapse
|
15
|
Hernández-Rodríguez JF, López MÁ, Rojas D, Escarpa A. Digital manufacturing for accelerating organ-on-a-chip dissemination and electrochemical biosensing integration. LAB ON A CHIP 2022; 22:4805-4821. [PMID: 36342332 DOI: 10.1039/d2lc00499b] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Organ on-a-chip (OoC) is a promising technology that aims to recapitulate human body pathophysiology in a more precise way to advance in drug development and complex disease understanding. However, the presence of OoC in biological laboratories is still limited and mainly restricted to laboratories with access to cleanroom facilities. Besides, the current analytical methods employed to extract information from the organ models are endpoint and post facto assays which makes it difficult to ensure that during the biological experiment the cell microenvironment, cellular functionality and behaviour are controlled. Hence, the integration of real-time biosensors is highly needed and requested by the OoC end-user community to provide insight into organ function and responses to stimuli. In this context, electrochemical sensors stand out due to their advantageous features like miniaturization capabilities, ease of use, automatization and high sensitivity and selectivity. Electrochemical sensors have been already successfully miniaturized and employed in other fields such as wearables and point-of-care devices. We have identified that the explanation for this issue may be, to a large extent, the accessibility to microfabrication technologies. These fields employ preferably digital manufacturing (DM), which is a more accessible microfabrication approach regardless of funding and facilities. Therefore, we envision that a paradigm shift in microfabrication that adopts DM instead of the dominating soft lithography for the in-lab microfabrication of OoC devices will contribute to the dissemination of the field and integration of the promising real-time sensing.
Collapse
Affiliation(s)
- Juan F Hernández-Rodríguez
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Madrid, Spain.
| | - Miguel Ángel López
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Madrid, Spain.
- Chemical Engineering and Chemical Research Institute "Andres M. Del Río", University of Alcalá, Madrid, Spain
| | - Daniel Rojas
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Madrid, Spain.
| | - Alberto Escarpa
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Madrid, Spain.
- Chemical Engineering and Chemical Research Institute "Andres M. Del Río", University of Alcalá, Madrid, Spain
| |
Collapse
|
16
|
Micro- and nano-devices for electrochemical sensing. Mikrochim Acta 2022; 189:459. [DOI: 10.1007/s00604-022-05548-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Accepted: 11/02/2022] [Indexed: 11/24/2022]
Abstract
AbstractElectrode miniaturization has profoundly revolutionized the field of electrochemical sensing, opening up unprecedented opportunities for probing biological events with a high spatial and temporal resolution, integrating electrochemical systems with microfluidics, and designing arrays for multiplexed sensing. Several technological issues posed by the desire for downsizing have been addressed so far, leading to micrometric and nanometric sensing systems with different degrees of maturity. However, there is still an endless margin for researchers to improve current strategies and cope with demanding sensing fields, such as lab-on-a-chip devices and multi-array sensors, brain chemistry, and cell monitoring. In this review, we present current trends in the design of micro-/nano-electrochemical sensors and cutting-edge applications reported in the last 10 years. Micro- and nanosensors are divided into four categories depending on the transduction mechanism, e.g., amperometric, impedimetric, potentiometric, and transistor-based, to best guide the reader through the different detection strategies and highlight major advancements as well as still unaddressed demands in electrochemical sensing.
Graphical Abstract
Collapse
|
17
|
Handrea-Dragan IM, Botiz I, Tatar AS, Boca S. Patterning at the micro/nano-scale: Polymeric scaffolds for medical diagnostic and cell-surface interaction applications. Colloids Surf B Biointerfaces 2022; 218:112730. [DOI: 10.1016/j.colsurfb.2022.112730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 07/15/2022] [Accepted: 07/25/2022] [Indexed: 11/27/2022]
|
18
|
Guglielmotti V, Saffioti NA, Tohmé AL, Gambarotta M, Corthey G, Pallarola D. A portable and affordable aligner for the assembly of microfluidic devices. HARDWAREX 2022; 12:e00348. [PMID: 36105917 PMCID: PMC9465365 DOI: 10.1016/j.ohx.2022.e00348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 08/09/2022] [Accepted: 08/16/2022] [Indexed: 06/15/2023]
Abstract
The incorporation of sophisticated capabilities within microfluidic devices often requires the assembly of different layers in a correct arrangement. For example, when it is desired to include electrodes inside microfluidic channels or to create 3D microfluidic structures. However, the alignment between different substrates at the microscale requires expensive equipment not available for all research groups. In this work, we present an affordable, compact and portable aligner for assembling multilayered composite microfluidic chips. The instrument is composed of aluminum machined pieces combined with precision stages and includes a digital microscope with a LED illumination system for monitoring the alignment process. An interchangeable holder was created for substrate fixing, allowing the bonding of PDMS with other materials. Microscopic visualization is achieved through any device with internet access, avoiding the need of a computer attached to the aligner. To test the performance of the aligner, the center of an indium tin oxide microelectrode on a glass substrate was aligned with the center of a microchannel in a PDMS chip. The accuracy and precision of the instrument are suited for many microfluidic applications. The small and inexpensive design of the aligner makes it a cost-effective option for small groups working in microfluidics.
Collapse
|
19
|
A Review on Potential Electrochemical Point-of-Care Tests Targeting Pandemic Infectious Disease Detection: COVID-19 as a Reference. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10070269] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Fast and accurate point-of-care testing (POCT) of infectious diseases is crucial for diminishing the pandemic miseries. To fight the pandemic coronavirus disease 2019 (COVID-19), numerous interesting electrochemical point-of-care (POC) tests have been evolved to rapidly identify the causal organism SARS-CoV-2 virus, its nucleic acid and antigens, and antibodies of the patients. Many of those electrochemical biosensors are impressive in terms of miniaturization, mass production, ease of use, and speed of test, and they could be recommended for future applications in pandemic-like circumstances. On the other hand, self-diagnosis, sensitivity, specificity, surface chemistry, electrochemical components, device configuration, portability, small analyzers, and other features of the tests can yet be improved. Therefore, this report reviews the developmental trend of electrochemical POC tests (i.e., test platforms and features) reported for the rapid diagnosis of COVID-19 and correlates any significant advancements with relevant references. POCTs incorporating microfluidic/plastic chips, paper devices, nanomaterial-aided platforms, smartphone integration, self-diagnosis, and epidemiological reporting attributes are also surfed to help with future pandemic preparedness. This review especially screens the low-cost and easily affordable setups so that management of pandemic disease becomes faster and easier. Overall, the review is a wide-ranging package for finding appropriate strategies of electrochemical POCT targeting pandemic infectious disease detection.
Collapse
|
20
|
Hsueh AJ, Mutalib NA, Shirato Y, Suzuki H. Bipolar Electrode Arrays for Chemical Imaging and Multiplexed Sensing. ACS OMEGA 2022; 7:20298-20305. [PMID: 35721987 PMCID: PMC9202012 DOI: 10.1021/acsomega.2c02298] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Accepted: 05/19/2022] [Indexed: 06/15/2023]
Abstract
Bipolar electrodes (BPEs) with arrays of cathodic and anodic poles were developed for use in closed bipolar systems. To increase the number of BPEs in the array, the anodic and cathodic poles were connected with each other using thin leads. A further increase in the number of BPEs was achieved by forming the cathodic and anodic poles of the BPEs and the leads in different layers. A device with 9 × 10 arrays of cathodes and anodes was thus realized. When using this device to sense hydrogen peroxide (H2O2), the sensitivity and linear range of calibration plots could be adjusted by changing the driving voltage and the area ratio between the cathodic and anodic poles. The devices were used to image H2O2 and obtain time-lapse images for the diffusion and dilution of H2O2. Furthermore, DNA detection was demonstrated using an electroactive intercalator. The sensitivity could be improved by making the anodic poles smaller with respect to the cathodic pole and concentrating the electrochemiluminescence (ECL) in a small area. The ECL intensity changed according to the target DNA concentration in the solution.
Collapse
Affiliation(s)
- An-Ju Hsueh
- Graduate
School of Science and Technology, University
of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Nurul Asyikeen
Ab Mutalib
- Graduate
School of Pure and Applied Sciences, University
of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Yusuke Shirato
- Graduate
School of Science and Technology, University
of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Hiroaki Suzuki
- Faculty
of Pure and Applied Sciences, University
of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| |
Collapse
|
21
|
Nadine S, Chung A, Diltemiz SE, Yasuda B, Lee C, Hosseini V, Karamikamkar S, de Barros NR, Mandal K, Advani S, Zamanian BB, Mecwan M, Zhu Y, Mofidfar M, Zare MR, Mano J, Dokmeci MR, Alambeigi F, Ahadian S. Advances in microfabrication technologies in tissue engineering and regenerative medicine. Artif Organs 2022; 46:E211-E243. [PMID: 35349178 DOI: 10.1111/aor.14232] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Revised: 02/02/2022] [Accepted: 02/28/2022] [Indexed: 12/17/2022]
Abstract
BACKGROUND Tissue engineering provides various strategies to fabricate an appropriate microenvironment to support the repair and regeneration of lost or damaged tissues. In this matter, several technologies have been implemented to construct close-to-native three-dimensional structures at numerous physiological scales, which are essential to confer the functional characteristics of living tissues. METHODS In this article, we review a variety of microfabrication technologies that are currently utilized for several tissue engineering applications, such as soft lithography, microneedles, templated and self-assembly of microstructures, microfluidics, fiber spinning, and bioprinting. RESULTS These technologies have considerably helped us to precisely manipulate cells or cellular constructs for the fabrication of biomimetic tissues and organs. Although currently available tissues still lack some crucial functionalities, including vascular networks, innervation, and lymphatic system, microfabrication strategies are being proposed to overcome these issues. Moreover, the microfabrication techniques that have progressed to the preclinical stage are also discussed. CONCLUSIONS This article aims to highlight the advantages and drawbacks of each technique and areas of further research for a more comprehensive and evolving understanding of microfabrication techniques in terms of tissue engineering and regenerative medicine applications.
Collapse
Affiliation(s)
- Sara Nadine
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, California, USA.,CICECO - Aveiro Institute of Materials, Department of Chemistry, University of Aveiro, Aveiro, Portugal
| | - Ada Chung
- Department of Psychology, University of California-Los Angeles, Los Angeles, California, USA
| | | | - Brooke Yasuda
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, California, USA.,Department of Psychology, University of California-Los Angeles, Los Angeles, California, USA
| | - Charles Lee
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, California, USA.,Department of Veterinary Pathobiology, Texas A&M University, College Station, Texas, USA.,Station 1, Lawrence, Massachusetts, USA
| | - Vahid Hosseini
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, California, USA
| | - Solmaz Karamikamkar
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, California, USA
| | | | - Kalpana Mandal
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, California, USA
| | - Shailesh Advani
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, California, USA
| | | | - Marvin Mecwan
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, California, USA
| | - Yangzhi Zhu
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, California, USA
| | - Mohammad Mofidfar
- Department of Chemistry, Stanford University, Palo Alto, California, USA
| | | | - João Mano
- CICECO - Aveiro Institute of Materials, Department of Chemistry, University of Aveiro, Aveiro, Portugal
| | - Mehmet Remzi Dokmeci
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, California, USA
| | - Farshid Alambeigi
- Walker Department of Mechanical Engineering, University of Texas at Austin, Austin, Texas, USA
| | - Samad Ahadian
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, California, USA
| |
Collapse
|
22
|
Zhang H, Wu Z, Zhi Z, Gao W, Sun W, Hua Z, Wu Y. Practical and Efficient: A Pocket-Sized Device Enabling Detection of Formaldehyde Adulteration in Vegetables. ACS OMEGA 2022; 7:160-167. [PMID: 35036687 PMCID: PMC8756785 DOI: 10.1021/acsomega.1c04229] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/07/2021] [Accepted: 12/17/2021] [Indexed: 06/14/2023]
Abstract
Formaldehyde, as a carcinogenic substance, is often intentionally used to adulterate vegetables to increase their shelf life, and the adhesive tape used to attach labels can also leave formaldehyde on the surface of vegetables. However, as the "gold" standard, gas chromatography (GC) and high-performance liquid chromatography (HPLC) are expensive for individual tests and confined to the laboratory owing to their size and a suitable detector (low-cost, portable, fast detection speed) to check formaldehyde contamination in vegetables not being available. Here, we tested formaldehyde contamination in vegetables using a low-cost and hand-held detector combined with a screen-printed electrode (SPE) amperometric sensor and an open-sourced potentiostat. The analyzer can detect a concentration of 100 μmol/L formaldehyde and achieve a good linear range between 100 and 1000 μmol/L. Furthermore, the detector successfully identified formaldehyde contamination in 53 samples of six different kinds of vegetables even after residual formaldehyde on the surface was evaporated. Most importantly, under the practicability-oriented idea, a cost-effective strategy was implemented for this detector design rather than using other pricey methods (e.g., photolithography, electron-beam evaporation, chemical deposition), which enormously reduces the cost (under ∼USD 0.5 per test) and meets all of the requirements of ASSURED device. We believe this cheap, portable detector could help law-enforcing authorities, healthcare workers, and customers to screen formaldehyde contamination easily. Also, the cost-saving strategy is appropriate for low-income areas, where there is a lack of laboratories, funds, and trained experts.
Collapse
|
23
|
Gutiérrez-Capitán M, Baldi A, Merlos Á, Fernández-Sánchez C. Array of individually addressable two-electrode electrochemical cells sharing a single counter/reference electrode for multiplexed enzyme activity measurements. Biosens Bioelectron 2022; 201:113952. [PMID: 34999523 DOI: 10.1016/j.bios.2021.113952] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 12/22/2021] [Accepted: 12/30/2021] [Indexed: 01/03/2023]
Abstract
This work reports on the fabrication and performance of a new on-chip array of gold thin-film electrodes arranged into five individually addressable miniaturized electrochemical cells. Each cell shows a two-electrode configuration comprising a single working electrode and a counter/pseudo-reference electrode that is compartmentalized to be shared among all the cells of the array. Using this configuration, just six contact pads are required, which significantly reduces the chip overall surface area. Electrochemical characterization studies are carried out in solutions containing the two species of reversible redox pairs. The concentration of one redox species can reliably be measured at the working electrode by applying potentiostatic techniques to record the current due to the corresponding electrochemical reaction. The redox counterpart in turn undergoes an electrochemical process at the counter/pseudo-reference electrode, which, under optimized experimental conditions, injects current and keeps the applied potential in the electrochemical cell without limiting the current being recorded at the working electrode. Under these conditions, the electrode array shows an excellent performance in electrochemical detection studies without any chemical or electrical cross-talk between cells. The enzymatic activity of horseradish peroxidase, alkaline phosphatase and myeloperoxidase enzymes is analyzed using different redox mediators. Quasi-simultaneous measurements with the five electrochemical cells of the array are carried out within 1 s time frame. This array layout can be suitable for multiplexed electrochemical immunoassays and immunosensor approaches and implementation in simplified electrochemical ELISA platforms that make use of enzyme labels. Moreover, the array reduced dimensions facilitate the integration into compact fluidic devices.
Collapse
Affiliation(s)
- Manuel Gutiérrez-Capitán
- Instituto de Microelectrónica de Barcelona (IMB-CNM), CSIC, Campus UAB, Bellaterra, 08193, Barcelona, Spain
| | - Antoni Baldi
- Instituto de Microelectrónica de Barcelona (IMB-CNM), CSIC, Campus UAB, Bellaterra, 08193, Barcelona, Spain
| | - Ángel Merlos
- Instituto de Microelectrónica de Barcelona (IMB-CNM), CSIC, Campus UAB, Bellaterra, 08193, Barcelona, Spain
| | - César Fernández-Sánchez
- Instituto de Microelectrónica de Barcelona (IMB-CNM), CSIC, Campus UAB, Bellaterra, 08193, Barcelona, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Jordi Girona 18-26, 08034, Barcelona, Spain.
| |
Collapse
|
24
|
Emran MY, El‐Safty SA, Elmarakbi A, Reda A, El Sabagh A, Shenashen MA. Chipset Nanosensor Based on N‐Doped Carbon Nanobuds for Selective Screening of Epinephrine in Human Samples. ADVANCED MATERIALS INTERFACES 2022; 9. [DOI: 10.1002/admi.202101473] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Indexed: 09/01/2023]
Abstract
AbstractChipset nanosensor design and fabrication are important for healthcare research and development. Herein, a functionalized chipset nanosensor is designed to monitor neurotransmitters (i.e., epinephrine (EP)) in human fluids. An interdigitated electrode array (IDA) is functionalized by N‐doped carbon nanobud (N‐CNB) and N‐doped carbon nanostructure (N‐CNS). The surface morphology of N‐CNB shows the formation of nanotubular‐like branches on sheets and micrometer‐size tubes. The N‐CNS design consists of the formation of aggregated sheets and particles in nanometer size. The irregular shape formation provides surface heterogeneity and numerous free spaces between the stacked nanostructures. N‐atoms ascertain highly active N‐CNS with multifunctional active centers, electron‐rich charged surface, and short distance pathway. The N‐CNB/IDA exhibits the best performance for EP signaling with high sensitivity and selectivity. The N‐CNB/IDA sensing performance for EP detection indicates the successful design of a highly selective and sensitive assay with low detection limit of 0.011 × 10−6 m and a broad linear range of 0.5 × 10−6 to 3 × 10−6 m. The N‐CNB/IDA exhibits a high degree of accuracy and reproducibility with RSD of 2.7% and 3.9%, respectively. Therefore, the chipset nanosensor of N‐CNB/IDA can be used for on‐site monitoring of EP in human serum samples and further used in daily monitoring of neuronal disorders.
Collapse
Affiliation(s)
- Mohammed Y. Emran
- National Institute for Materials Science (NIMS) Research Center for Functional Materials 1‐2‐1 Sengen Tsukuba‐shi Ibaraki‐ken 305‐0047 Japan
| | - Sherif A. El‐Safty
- National Institute for Materials Science (NIMS) Research Center for Functional Materials 1‐2‐1 Sengen Tsukuba‐shi Ibaraki‐ken 305‐0047 Japan
| | - Ahmed Elmarakbi
- Faculty of Engineering and Environment Northumbria University Newcastle upon Tyne NE1 8ST UK
| | - Abduallah Reda
- National Institute for Materials Science (NIMS) Research Center for Functional Materials 1‐2‐1 Sengen Tsukuba‐shi Ibaraki‐ken 305‐0047 Japan
| | - Ayman El Sabagh
- Department of Field Crops Faculty of Agriculture Siirt University Siirt 56100 Turkey
| | - Mohamed A. Shenashen
- National Institute for Materials Science (NIMS) Research Center for Functional Materials 1‐2‐1 Sengen Tsukuba‐shi Ibaraki‐ken 305‐0047 Japan
- Department of Petrochemical Egyptian Petroleum Research Institute (EPRI) Nasr City Cairo 11727 Egypt
| |
Collapse
|
25
|
Biswas GC, Suzuki H. Simple manual roller pump-driven valve-free microfluidic solution exchange system for urgent bioassay. RSC Adv 2022; 12:2938-2946. [PMID: 35425303 PMCID: PMC8979114 DOI: 10.1039/d1ra08052k] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Accepted: 01/16/2022] [Indexed: 12/22/2022] Open
Abstract
We introduce a simple-to-use manual roller pump (MRP)-driven and valve-free microfluidic system for sequential solution exchange, followed by a bioassay to detect protein. The polydimethylsiloxane (PDMS)/glass-based disposable device comprises a reaction chamber, multiple micro-flow channels (μFCs), and air vents. The practical solution exchange was realized by sequential injection and withdrawal of several solutions into and from the reaction chamber through constricted μFCs by utilizing changing air pressure of an MRP when a small cylindrical roller was pressed and rolled over a soft silicone tube using a finger. Furthermore, we investigated the effect of surface hydrophobicity on solution exchange. A sandwich fluorescence-based immunoassay to detect human interleukin 2 (IL-2) was performed using this simple microfluidic scheme to demonstrate its suitability for analytical bioassays. The system allowed quick IL-2 detection in 20 min in a pre-functionalized device with a detection limit of 80 pg mL−1 and a range of 125 pg mL−1 to 2.0 ng mL−1. We have thus developed a microfluidic scheme that non-experts can efficiently perform and that can be the fundamental module for low-cost bioassays necessary for emergencies and situations where resources are constrained. We report an easy microfluidic solution exchange system that employs a finger-driven manual roller pump (MRP) and valveless micro-flow structures to enable minimally trained personnel to execute instantaneous stepwise bioassays.![]()
Collapse
Affiliation(s)
- Gokul Chandra Biswas
- School of Life Sciences, Shahjalal University of Science and Technology, Sylhet-3114, Bangladesh
| | - Hiroaki Suzuki
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8573, Japan
| |
Collapse
|
26
|
Komori K, Usui M, Hatano K, Hori Y, Hirono K, Zhu D, Tokito F, Nishikawa M, Sakai Y, Kimura H. In vitro enzymatic electrochemical monitoring of glucose metabolism and production in rat primary hepatocytes on highly O 2 permeable plates. Bioelectrochemistry 2021; 143:107972. [PMID: 34666223 DOI: 10.1016/j.bioelechem.2021.107972] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2021] [Revised: 09/27/2021] [Accepted: 09/28/2021] [Indexed: 12/12/2022]
Abstract
In situ continuous glucose monitoring under physiological culture conditions is imperative in understanding the dynamics of cell and tissue behaviors and their physiological responses since glucose plays an important role in principal source of biological energy. We therefore examined physiologically relevant dynamic changes in glucose levels based on glucose metabolism and production during aerobic culture (10% O2) of rat primary hepatocytes stimulated with insulin or glucagon on a highly O2 permeable plate, which can maintain the oxygen concentration close to the periportal zone of the liver. As glucose monitoring devices, we used oxygen-independent glucose dehydrogenase-modified single-walled carbon nanotube electrodes placed close to the surface of the hepatocytes. The current response of glucose oxidation slightly decreased after the addition of insulin in the presence of glucose due to the acceleration of glucose uptake by the hepatocytes, whereas that significantly increased after the addition of glucagon and fructose even in the absence of glucose due to the conversion of fructose to glucose based on gluconeogenesis. These phenomena might be consistent relatively with the physiological behaviors of hepatocytes in the periportal region. The present monitoring system would be useful for the studies of glucose homeostasis and diabetes in vitro.
Collapse
Affiliation(s)
- Kikuo Komori
- Department of Biotechnology and Chemistry, Kindai University, Takaya-Umenobe, Higashi-Hiroshima 739-2116, Japan; Department of Chemical System Engineering, The University of Tokyo, Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.
| | - Masataka Usui
- Department of Chemical System Engineering, The University of Tokyo, Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Kohei Hatano
- Department of Chemical System Engineering, The University of Tokyo, Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Yuma Hori
- Department of Biotechnology and Chemistry, Kindai University, Takaya-Umenobe, Higashi-Hiroshima 739-2116, Japan
| | - Keita Hirono
- Department of Chemical System Engineering, The University of Tokyo, Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Dongchen Zhu
- Department of Chemical System Engineering, The University of Tokyo, Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Fumiya Tokito
- Department of Chemical System Engineering, The University of Tokyo, Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Masaki Nishikawa
- Department of Chemical System Engineering, The University of Tokyo, Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Yasuyuki Sakai
- Department of Chemical System Engineering, The University of Tokyo, Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | - Hiroshi Kimura
- Department of Mechanical Engineering, Tokai University, Kitakaname, Hiratsuka, Kanagawa 259-1292, Japan
| |
Collapse
|
27
|
Applications of Microfluidics in Liquid Crystal-Based Biosensors. BIOSENSORS-BASEL 2021; 11:bios11100385. [PMID: 34677341 PMCID: PMC8534167 DOI: 10.3390/bios11100385] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 10/08/2021] [Accepted: 10/09/2021] [Indexed: 02/06/2023]
Abstract
Liquid crystals (LCs) with stimuli-responsive configuration transition and optical anisotropic properties have attracted enormous interest in the development of simple and label-free biosensors. The combination of microfluidics and the LCs offers great advantages over traditional LC-based biosensors including small sample consumption, fast analysis and low cost. Moreover, microfluidic techniques provide a promising tool to fabricate uniform and reproducible LC-based sensing platforms. In this review, we emphasize the recent development of microfluidics in the fabrication and integration of LC-based biosensors, including LC planar sensing platforms and LC droplets. Fabrication and integration of LC-based planar platforms with microfluidics for biosensing applications are first introduced. The generation and entrapment of monodisperse LC droplets with different microfluidic structures, as well as their applications in the detection of chemical and biological species, are then summarized. Finally, the challenges and future perspectives of the development of LC-based microfluidic biosensors are proposed. This review will promote the understanding of microfluidic techniques in LC-based biosensors and facilitate the development of LC-based microfluidic biosensing devices with high performance.
Collapse
|
28
|
Zhang S, Wang J, Hayashi K, Sassa F. Monolithic processing of a layered flexible robotic actuator film for kinetic electronics. Sci Rep 2021; 11:20015. [PMID: 34625622 PMCID: PMC8501038 DOI: 10.1038/s41598-021-99500-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Accepted: 09/24/2021] [Indexed: 02/08/2023] Open
Abstract
Low-invasive soft robotic techniques can potentially be used for developing next-generation body-machine interfaces. Most soft robots require complicated fabrication processes involving 3D printing and bonding/assembling. In this letter, we describe a monolithic soft microrobot fabrication process for the mass production of soft film robots with a complex structure by simple 2D processing of a robotic actuator film. The 45 µg/mm2 lightweight film robot can be driven at a voltage of CMOS compatible 5 V with 0.15 mm-1 large curvature changes; it can generate a force 5.7 times greater than its self-weight. In a durability test, actuation could be carried out over 8000 times without degradation. To further demonstrate this technique, three types of film robots with multiple degrees of freedom and a moving illuminator robot were fabricated. This technique can easily integrate various electrical circuits developed in the past to robotic systems and can be used for developing advanced wearable sensing devices; it can be called "Kinetic electronics".
Collapse
Affiliation(s)
- Shiyi Zhang
- grid.177174.30000 0001 2242 4849Graduate School of Information Science and Electrical Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395 Japan
| | - Joseph Wang
- grid.266100.30000 0001 2107 4242Department of Nanoengineering, Center of Wearable Sensors, University of California San Diego, La Jolla, CA USA
| | - Kenshi Hayashi
- grid.177174.30000 0001 2242 4849Graduate School of Information Science and Electrical Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395 Japan
| | - Fumihiro Sassa
- grid.177174.30000 0001 2242 4849Graduate School of Information Science and Electrical Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395 Japan
| |
Collapse
|
29
|
Satoh Y, Ding H, Yang H, Deng Y, Hsueh AJ, Shimizu T, Qiao M, Ma C, Kariya K, Kurihara T, Suzuki H. Wired Microfabricated Electrochemical Systems. Anal Chem 2021; 93:12655-12663. [PMID: 34476942 DOI: 10.1021/acs.analchem.1c02461] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Metal wires have been used as an alternative to liquid junctions for the connection of solutions in microfabricated electrochemical devices. They exhibit similar performance to liquid junctions, provided that the interfacial potentials at both ends of the wires were appropriately canceled. Cyclic voltammograms of devices with liquid junctions and metal wires were very similar when no current or a low current flowed through the metal wire between the working and reference electrodes. Iridium wires with iridium oxide at both ends facilitated canceling of the interfacial potentials at either end of the junction particularly well, and were used effectively for voltammetry, amperometry, and potentiometry by adjusting the pH of the solutions in the working and reference electrode compartments to be equal. This approach was used to effectively integrate a reliable common reference electrode between multiple working electrodes and to conduct automated electrochemical control of solution transport in microfluidic systems.
Collapse
Affiliation(s)
- Yusei Satoh
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Hanlin Ding
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Hao Yang
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Yi Deng
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - An-Ju Hsueh
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Tetsuro Shimizu
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Mu Qiao
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Chengrui Ma
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Koki Kariya
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Toshiaki Kurihara
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Hiroaki Suzuki
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| |
Collapse
|
30
|
Abstract
Electrochemistry represents an important analytical technique used to acquire and assess chemical information in detail, which can aid fundamental investigations in various fields, such as biological studies. For example, electrochemistry can be used as simple and cost-effective means for bio-marker tracing in applications, such as health monitoring and food security screening. In combination with light, powerful spatially-resolved applications in both the investigation and manipulation of biochemical reactions begin to unfold. In this article, we focus primarily on light-addressable electrochemistry based on semiconductor materials and light-readable electrochemistry enabled by electrochemiluminescence (ECL). In addition, the emergence of multiplexed and imaging applications will also be introduced.
Collapse
|
31
|
Bao B, Rivkin B, Akbar F, Karnaushenko DD, Bandari VK, Teuerle L, Becker C, Baunack S, Karnaushenko D, Schmidt OG. Digital Electrochemistry for On-Chip Heterogeneous Material Integration. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2101272. [PMID: 34028906 DOI: 10.1002/adma.202101272] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Revised: 03/30/2021] [Indexed: 06/12/2023]
Abstract
Many modern electronic applications rely on functional units arranged in an active-matrix integrated on a single chip. The active-matrix allows numerous identical device pixels to be addressed within a single system. However, next-generation electronics requires heterogeneous integration of dissimilar devices, where sensors, actuators, and display pixels sense and interact with the local environment. Heterogeneous material integration allows the reduction of size, increase of functionality, and enhancement of performance; however, it is challenging since front-end fabrication technologies in microelectronics put extremely high demands on materials, fabrication protocols, and processing environments. To overcome the obstacle in heterogeneous material integration, digital electrochemistry is explored here, which site-selectively carries out electrochemical processes to deposit and address electroactive materials within the pixel array. More specifically, an amorphous indium-gallium-zinc oxide (a-IGZO) thin-film-transistor (TFT) active-matrix is used to address pixels within the matrix and locally control electrochemical reactions for material growth and actuation. The digital electrochemistry procedure is studied in-depth by using polypyrrole (PPy) as a model material. Active-matrix-driven multicolored electrochromic patterns and actuator arrays are fabricated to demonstrate the capabilities of this approach for material integration. The approach can be extended to a broad range of materials and structures, opening up a new path for advanced heterogeneous microsystem integration.
Collapse
Affiliation(s)
- Bin Bao
- Institute for Integrative Nanosciences, Leibniz IFW Dresden, 01069, Dresden, Germany
| | - Boris Rivkin
- Institute for Integrative Nanosciences, Leibniz IFW Dresden, 01069, Dresden, Germany
| | - Farzin Akbar
- Institute for Integrative Nanosciences, Leibniz IFW Dresden, 01069, Dresden, Germany
| | | | - Vineeth Kumar Bandari
- Institute for Integrative Nanosciences, Leibniz IFW Dresden, 01069, Dresden, Germany
- Material Systems for Nanoelectronics, Chemnitz University of Technology, 09107, Chemnitz, Germany
- Center for Materials, Architectures and Integration of Nanomembranes (MAIN), Chemnitz University of Technology, 09126, Chemnitz, Germany
| | - Laura Teuerle
- Institute for Integrative Nanosciences, Leibniz IFW Dresden, 01069, Dresden, Germany
| | - Christian Becker
- Institute for Integrative Nanosciences, Leibniz IFW Dresden, 01069, Dresden, Germany
| | - Stefan Baunack
- Institute for Integrative Nanosciences, Leibniz IFW Dresden, 01069, Dresden, Germany
| | - Daniil Karnaushenko
- Institute for Integrative Nanosciences, Leibniz IFW Dresden, 01069, Dresden, Germany
| | - Oliver G Schmidt
- Institute for Integrative Nanosciences, Leibniz IFW Dresden, 01069, Dresden, Germany
- Material Systems for Nanoelectronics, Chemnitz University of Technology, 09107, Chemnitz, Germany
- Center for Materials, Architectures and Integration of Nanomembranes (MAIN), Chemnitz University of Technology, 09126, Chemnitz, Germany
- Nanophysics, Faculty of Physics, TU Dresden, 01062, Dresden, Germany
| |
Collapse
|
32
|
Electrochemical Discrimination of Salbutamol from Its Excipients in Ventolin TM at Nanoporous Gold Microdisc Arrays. SENSORS 2021; 21:s21123975. [PMID: 34207616 PMCID: PMC8226559 DOI: 10.3390/s21123975] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 05/23/2021] [Accepted: 05/31/2021] [Indexed: 02/02/2023]
Abstract
The emergence of specific drug–device combination products in the inhalable pharmaceutical industry demands more sophistication of device functionality in the form of an embedded sensing platform to increase patient safety and extend patent coverage. Controlling the nebuliser function at a miniaturised, integrated electrochemical sensing platform with rapid response time and supporting novel algorithms could deliver such a technology offering. Development of a nanoporous gold (NPG) electrochemical sensor capable of creating a unique fingerprint signal generated by inhalable pharmaceuticals provided the impetus for our study of the electrooxidation of salbutamol, which is the active bronchodilatory ingredient in VentolinTM formulations. It was demonstrated that, at NPG-modified microdisc electrode arrays, salbutamol is distinguishable from the chloride excipient present at 0.0154 M using linear sweep voltammetry and can be detected amperometrically. In contrast, bare gold microdisc electrode arrays cannot afford such discrimination, as the potential for salbutamol oxidation and chloride adsorption reactions overlap. The discriminative power of NPG originates from the nanoconfinement effect for chloride in the internal pores of NPG, which selectively enhances the electron transfer kinetics of this more sluggish reaction relative to that of the faster, diffusion-controlled salbutamol oxidation. Sensing was performed at a fully integrated three-electrode cell-on-chip using Pt as a quasi-reference electrode.
Collapse
|
33
|
Thaweeskulchai T, Schulte A. Sustainable and Efficient: A Reusable DIY Three-Electrode Base Plate for Microfluidic Electroanalysis and Biosensing. Anal Chem 2021; 93:7557-7561. [PMID: 33998230 DOI: 10.1021/acs.analchem.1c00996] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A sustainable three-electrode platform for affordable microfluidic electroanalysis is described. The device can be handmade using common tools and, facilitating broad applicability, is indefinitely reusable through simple surface polishing. Compact prototypes with Pt counter, Pt working, and Ag/AgCl reference electrode disks were combined with silicone lid plates containing a microchannel for electrolyte flow. Redox voltammetry/amperometry of excellent quality was achieved in static and flowing ferricyanide solutions, respectively. Modified with a glucose oxidase surface layer, base plate Pt WEs performed very well as amperometric biosensors for microfluidic blood glucose testing. The electrode system is recyclable, compatible with matching lid plate microchannels, and functionally adaptable regarding the constituent metal and electrode surface modifications. This asset combination makes the device a sustainable detection tool for microfluidic electroanalysis, with applications ranging from direct detection of redox-active analytes to bioreceptor-assisted biosensing. It avoids costly microfabrication with clean-room use, and the accessibility of microfluidic EC (bio)sensing is thus greatly increased, especially for users with restricted budgets.
Collapse
Affiliation(s)
- Thana Thaweeskulchai
- School of Biomolecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Wang Chan Valley, Rayong 21210, Thailand
| | - Albert Schulte
- School of Biomolecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Wang Chan Valley, Rayong 21210, Thailand
| |
Collapse
|
34
|
Maximiano EM, Gonçalves DA, Martins CA, Angnes L, Gomes RS, Trindade MAG. Simultaneous separation and electroanalysis in a single polydimethylsiloxane-based platform. Talanta 2021; 233:122514. [PMID: 34215129 DOI: 10.1016/j.talanta.2021.122514] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 05/04/2021] [Accepted: 05/08/2021] [Indexed: 11/15/2022]
Abstract
Channel-based microfluidic devices integrating the separation step and detection system are key factors to expand microanalysis application. However, these devices still depend on macroscale external equipment for pre-treatment of the sample, separation, or detection. The integration of all steps in only one stage is critical to improving feasibility. Herein, we use a low-cost protocol to solve part of the challenge by designing a dual-mode system onto single polydimethylsiloxane (PDMS)-based platform - overall dimensions of 65 mm length × 20 mm width × 14 mm height and the inner diameter of 297±10 μm height × 605±19 μm width - for column-free separation and simultaneous detection. As a proof-of-concept, we used this all-in-one PDMS platform to separate - without the packet-based phase - and determine salicylic acid (SA) and caffeine (CAF) with a detection limit of 0.20 and 0.18 μmol L-1 and quantification limit of 0.70 and 0.60 μmol L-1 for SA and CAF, respectively. We separated the mixture using forced convection into a chemically treated microchannel while detecting the analytes in amperometric mode. Here, we report new insights into how integrating analytes separation and further electroanalysis into a single miniaturized device.
Collapse
Affiliation(s)
- Elizabete M Maximiano
- Faculdade de Ciências Exatas e Tecnologia, Universidade Federal da Grande Dourados, Rodovia Dourados-Itahum, km 12, CEP 79804-970, Dourados, MS, Brazil
| | - Daniel A Gonçalves
- Faculdade de Ciências Exatas e Tecnologia, Universidade Federal da Grande Dourados, Rodovia Dourados-Itahum, km 12, CEP 79804-970, Dourados, MS, Brazil
| | - Cauê A Martins
- Institute of Physics, Universidade Federal de Mato Grosso do Sul, CEP 79070-900, Campo Grande, MS, Brazil
| | - Lucio Angnes
- Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes, 748, CEP 05508-000, São Paulo, SP, Brazil
| | - Roberto S Gomes
- Department of Pharmaceutical Sciences, North Dakota State University, Fargo, ND, USA
| | - Magno A G Trindade
- Faculdade de Ciências Exatas e Tecnologia, Universidade Federal da Grande Dourados, Rodovia Dourados-Itahum, km 12, CEP 79804-970, Dourados, MS, Brazil; Unesp, National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry, CEP 14800-900, Araraquara, SP, Brazil.
| |
Collapse
|
35
|
Hsueh AJ, Park S, Satoh T, Shimizu T, Koiwai K, Nakashima M, Morimoto Y, Kinoshita M, Suzuki H. Microdevice with an Integrated Clark-Type Oxygen Electrode for the Measurement of the Respiratory Activity of Cells. Anal Chem 2021; 93:5577-5585. [PMID: 33769050 DOI: 10.1021/acs.analchem.1c00227] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A microdevice for the measurement of the respiratory activity of cells was fabricated using a microfabricated Clark-type oxygen electrode. The oxygen electrode was completed in a dry state and was activated by introducing water necessary for the reduction of oxygen in the form of water vapor through an oxygen-permeable membrane, which significantly facilitated handling of the device even by nonspecialists. The use of a thin paper layer stabilized the current response and enabled stable continuous operation of the oxygen electrode without current disturbance caused by the evaporation of water. The microdevice was tested in some model experiments including the measurement of the respiratory activity of Escherichia coli (E. coli), evaluation of the efficacy of antibiotics, and measurement of the antibacterial activity of neutrophils, all of which demonstrated that the consumption of dissolved oxygen by cells can be monitored clearly by following an easy procedure for the preparation of the measurements.
Collapse
Affiliation(s)
- An-Ju Hsueh
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Sunho Park
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Tatsuya Satoh
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Tetsuro Shimizu
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| | - Kazuki Koiwai
- Department of Immunology and Microbiology, National Defense Medical College, Namiki 3-2, Tokorozawa 359-8513, Japan
| | - Masahiro Nakashima
- Department of Immunology and Microbiology, National Defense Medical College, Namiki 3-2, Tokorozawa 359-8513, Japan
| | - Yuji Morimoto
- Department of Physiology, National Defense Medical College, Namiki 3-2, Tokorozawa 359-8513, Japan
| | - Manabu Kinoshita
- Department of Immunology and Microbiology, National Defense Medical College, Namiki 3-2, Tokorozawa 359-8513, Japan
| | - Hiroaki Suzuki
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8573, Japan
| |
Collapse
|
36
|
Oliveira M, Conceição P, Kant K, Ainla A, Diéguez L. Electrochemical Sensing in 3D Cell Culture Models: New Tools for Developing Better Cancer Diagnostics and Treatments. Cancers (Basel) 2021; 13:1381. [PMID: 33803738 PMCID: PMC8003119 DOI: 10.3390/cancers13061381] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 03/08/2021] [Accepted: 03/12/2021] [Indexed: 02/07/2023] Open
Abstract
Currently, conventional pre-clinical in vitro studies are primarily based on two-dimensional (2D) cell culture models, which are usually limited in mimicking the real three-dimensional (3D) physiological conditions, cell heterogeneity, cell to cell interaction, and extracellular matrix (ECM) present in living tissues. Traditionally, animal models are used to mimic the 3D environment of tissues and organs, but they suffer from high costs, are time consuming, bring up ethical concerns, and still present many differences when compared to the human body. The applications of microfluidic-based 3D cell culture models are advantageous and useful as they include 3D multicellular model systems (MCMS). These models have demonstrated potential to simulate the in vivo 3D microenvironment with relatively low cost and high throughput. The incorporation of monitoring capabilities in the MCMS has also been explored to evaluate in real time biophysical and chemical parameters of the system, for example temperature, oxygen, pH, and metabolites. Electrochemical sensing is considered as one of the most sensitive and commercially adapted technologies for bio-sensing applications. Amalgamation of electrochemical biosensing with cell culture in microfluidic devices with improved sensitivity and performance are the future of 3D systems. Particularly in cancer, such models with integrated sensing capabilities can be crucial to assess the multiple parameters involved in tumour formation, proliferation, and invasion. In this review, we are focusing on existing 3D cell culture systems with integrated electrochemical sensing for potential applications in cancer models to advance diagnosis and treatment. We discuss their design, sensing principle, and application in the biomedical area to understand the potential relevance of miniaturized electrochemical hybrid systems for the next generation of diagnostic platforms for precision medicine.
Collapse
Affiliation(s)
- Micaela Oliveira
- Medical Devices Research Group, International Iberian Nanotechnology Laboratory (INL), 4715-330 Braga, Portugal; (M.O.); (P.C.); (K.K.); (A.A.)
| | - Pedro Conceição
- Medical Devices Research Group, International Iberian Nanotechnology Laboratory (INL), 4715-330 Braga, Portugal; (M.O.); (P.C.); (K.K.); (A.A.)
- Chemistry Department, University of Aveiro, 3810-193 Aveiro, Portugal
| | - Krishna Kant
- Medical Devices Research Group, International Iberian Nanotechnology Laboratory (INL), 4715-330 Braga, Portugal; (M.O.); (P.C.); (K.K.); (A.A.)
| | - Alar Ainla
- Medical Devices Research Group, International Iberian Nanotechnology Laboratory (INL), 4715-330 Braga, Portugal; (M.O.); (P.C.); (K.K.); (A.A.)
| | - Lorena Diéguez
- Medical Devices Research Group, International Iberian Nanotechnology Laboratory (INL), 4715-330 Braga, Portugal; (M.O.); (P.C.); (K.K.); (A.A.)
| |
Collapse
|
37
|
Alsabbagh K, Hornung T, Voigt A, Sadir S, Rajabi T, Länge K. Microfluidic Impedance Biosensor Chips Using Sensing Layers Based on DNA-Based Self-Assembled Monolayers for Label-Free Detection of Proteins. BIOSENSORS-BASEL 2021; 11:bios11030080. [PMID: 33805676 PMCID: PMC8001378 DOI: 10.3390/bios11030080] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Revised: 03/08/2021] [Accepted: 03/10/2021] [Indexed: 11/30/2022]
Abstract
A microfluidic chip for electrochemical impedance spectroscopy (EIS) is presented as bio-sensor for label-free detection of proteins by using the example of cardiac troponin I. Troponin I is one of the most specific diagnostic serum biomarkers for myocardial infarction. The microfluidic impedance biosensor chip presented here consists of a microscope glass slide serving as base plate, sputtered electrodes, and a polydimethylsiloxane (PDMS) microchannel. Electrode functionalization protocols were developed considering a possible charge transfer through the sensing layer, in addition to analyte-specific binding by corresponding antibodies and reduction of nonspecific protein adsorption to prevent false-positive signals. Reagents tested for self-assembled monolayers (SAMs) on gold electrodes included thiolated hydrocarbons and thiolated oligonucleotides, where SAMs based on the latter showed a better performance. The corresponding antibody was covalently coupled on the SAM using carbodiimide chemistry. Sampling and measurement took only a few minutes. Application of a human serum albumin (HSA) sample, 1000 ng/mL, led to negligible impedance changes, while application of a troponin I sample, 1 ng/mL, led to a significant shift in the Nyquist plot. The results are promising regarding specific detection of clinically relevant concentrations of biomarkers, such as cardiac markers, with the newly developed microfluidic impedance biosensor chip.
Collapse
Affiliation(s)
- Khaled Alsabbagh
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany; (K.A.); (T.H.); (A.V.); (T.R.)
| | - Tim Hornung
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany; (K.A.); (T.H.); (A.V.); (T.R.)
| | - Achim Voigt
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany; (K.A.); (T.H.); (A.V.); (T.R.)
| | - Sahba Sadir
- Institute for Micro Process Engineering, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany;
| | - Taleieh Rajabi
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany; (K.A.); (T.H.); (A.V.); (T.R.)
| | - Kerstin Länge
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany; (K.A.); (T.H.); (A.V.); (T.R.)
- Correspondence:
| |
Collapse
|
38
|
Jalali M, Isaac Hosseini I, AbdelFatah T, Montermini L, Wachsmann Hogiu S, Rak J, Mahshid S. Plasmonic nanobowtiefluidic device for sensitive detection of glioma extracellular vesicles by Raman spectrometry. LAB ON A CHIP 2021; 21:855-866. [PMID: 33514986 DOI: 10.1039/d0lc00957a] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Cancer cells shed into biofluids extracellular vesicles (EVs) - nanoscale membrane particles carrying diagnostic information. EVs shed by heterogeneous populations of tumor cells offer a unique opportunity to access biologically important aspects of disease complexity. Glioblastoma (GBM) exemplifies cancers that are incurable, because their temporal dynamics and molecular complexity evade standard diagnostic methods and confound therapeutic efforts. Liquid biopsy based on EVs offers unprecedented real-time access to complex tumour signatures, but it is not used clinically due to inefficient testing methods. We report on a nanostructured microfluidic-device that employs SERS for unambiguous identification of EVs from different GBM cell populations. The device features fabless plasmonic nanobowties for label-free and non-immunological SERS detection of EVs. This nanobowtiefluidic device combines the advanced characteristics of plasmonic nanobowties with a high throughput sample-delivery system for concentration of the analytes in the vicinity of the detection site. We showed theoretically and experimentally that the fluidic device assists the monolayer distribution of the EVs, which dramatically increase the probability of EV's existence in the laser illumination area. In addition, the optimized fabless nanobowtie structures with an average electric field enhancement factor of 9 × 105 achieve distinguishable and high intensity SERS signals. Using the nanobowtiefluidic and micro-Raman equipment, we were able to distinguish a library of peaks expressed in GBM EV subpopulations from two distinct glioblastoma cell lines (U373, U87) and compare them to those of non-cancerous glial EVs (NHA) and artificial homogenous vesicles (e.g. DOPC/Chol). This cost-effective and easy-to-fabricate SERS platform and a portable sample-delivery system for discerning the sub-population of GBM EVs and non-cancerous glial EVs may have broader applications to different types of cancer cells and their molecular/oncogenic signature.
Collapse
Affiliation(s)
- Mahsa Jalali
- Department of Bioengineering, McGill University, Montreal, QC H3A 0E9, Canada
| | | | | | | | | | | | | |
Collapse
|
39
|
Sarkar P, Konch TJ, Kamilya T, Raidongia K, Acharya S, Mukherjee C. The range of antiferromagnetic coupling governs the conductivity: semiconducting behavior and ammonia gas sensing property of diamagnetic hexaradical-containing tetranuclear Co III4 cluster and its nonradical congener. Chem Commun (Camb) 2020; 56:15220-15223. [PMID: 33231224 DOI: 10.1039/d0cc04061d] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Long-range antiferromagnetic coupling impeded electron flow through the hexaradical-containing tetranuclear CoIII4 complex (1), while the nonradical-containing tetranuclear CoIII4 complex (2), with no paramagnetic centres, was a semiconductor and sensed NH3 efficiently at room temperature (25 °C).
Collapse
Affiliation(s)
- Prasenjit Sarkar
- Department of Chemistry, Indian Institute of Technology Guwahati, Assam-781039, India.
| | | | | | | | | | | |
Collapse
|
40
|
Hernández-Rodríguez JF, Rojas D, Escarpa A. Electrochemical Sensing Directions for Next-Generation Healthcare: Trends, Challenges, and Frontiers. Anal Chem 2020; 93:167-183. [PMID: 33174738 DOI: 10.1021/acs.analchem.0c04378] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Juan F Hernández-Rodríguez
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain
| | - Daniel Rojas
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain.,Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, 64100 Teramo, Italy
| | - Alberto Escarpa
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain.,Chemical Research Institute Andres M. del Rio, University of Alcalá, E-28871 Madrid, Spain
| |
Collapse
|
41
|
Compact analytical flow system for the simultaneous determination of L-lactic and L-malic in red wines. Sci Rep 2020; 10:19404. [PMID: 33173191 PMCID: PMC7656249 DOI: 10.1038/s41598-020-76502-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2020] [Accepted: 10/28/2020] [Indexed: 11/12/2022] Open
Abstract
During the malolactic fermentation of red wines, l-malic acid is mainly converted to l-lactic acid. Both acids should be precisely measured during the entire process to guarantee the quality of the final wine, thus making real-time monitoring approaches of great importance in the winemaking industry. Traditional analytical methods based on laboratory procedures are currently applied and cannot be deployed on-site. In this work, we report on the design and development of a bi-parametric compact analytical flow system integrating two electrochemical biosensors that could be potentially applied in this scenario. The developed flow-system will allow for the first time the simultaneous measurement of both acids in real scenarios at the real-time and in remote way. Miniaturized thin-film platinum four-electrode chips are fabricated on silicon substrates by standard photolithographic techniques and further implemented in a polymeric fluidic structure. This includes a 15 µL flow cell together with the required fluidic channels for sample and reagent fluid management. The four-electrode chip includes counter and pseudo-reference electrodes together with two working electrodes. These are sequentially modified with electropolymerized polypyrrole membranes that entrap the specific receptors for selectively detecting both target analytes. The analytical performance of both biosensors is studied by chronoamperometry, showing a linear range from 5 × 10−6 to 1 × 10−4 M (LOD of 3.2 ± 0.3 × 10−6 M) and from 1 × 10−7 to 1 × 10−6 M (LOD of 6.7 ± 0.2 × 10−8 M) for the l-lactate and the l-malate, respectively. Both biosensors show long-term stability, retaining more than the 90% of their initial sensitivity after more than 30 days, this being a prerequisite for monitoring the whole process of the malolactic fermentation of the red wines (time between 20 and 40 days). The flow system performance is assessed with several wine samples collected during the malolactic fermentation process of three red wines, showing an excellent agreement with the results obtained with the standard method.
Collapse
|
42
|
Spychalska K, Zając D, Baluta S, Halicka K, Cabaj J. Functional Polymers Structures for (Bio)Sensing Application-A Review. Polymers (Basel) 2020; 12:E1154. [PMID: 32443618 PMCID: PMC7285029 DOI: 10.3390/polym12051154] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Revised: 05/13/2020] [Accepted: 05/15/2020] [Indexed: 11/16/2022] Open
Abstract
In this review we present polymeric materials for (bio)sensor technology development. We focused on conductive polymers (conjugated microporous polymer, polymer gels), composites, molecularly imprinted polymers and their influence on the design and fabrication of bio(sensors), which in the future could act as lab-on-a-chip (LOC) devices. LOC instruments enable us to perform a wide range of analysis away from the stationary laboratory. Characterized polymeric species represent promising candidates in biosensor or sensor technology for LOC development, not only for manufacturing these devices, but also as a surface for biologically active materials' immobilization. The presence of biological compounds can improve the sensitivity and selectivity of analytical tools, which in the case of medical diagnostics is extremely important. The described materials are biocompatible, cost-effective, flexible and are an excellent platform for the anchoring of specific compounds.
Collapse
Affiliation(s)
| | | | | | | | - Joanna Cabaj
- Faculty of Chemistry, Wrocław University of Science and Technology, 50-137 Wrocław, Poland; (K.S.); (D.Z.); (S.B.); (K.H.)
| |
Collapse
|