1
|
Idili A, Montón H, Medina-Sánchez M, Ibarlucea B, Cuniberti G, Schmidt OG, Plaxco KW, Parolo C. Continuous monitoring of molecular biomarkers in microfluidic devices. PROGRESS IN MOLECULAR BIOLOGY AND TRANSLATIONAL SCIENCE 2022; 187:295-333. [PMID: 35094779 DOI: 10.1016/bs.pmbts.2021.07.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
The ability to monitor molecular targets is crucial in fields ranging from healthcare to industrial processing to environmental protection. Devices employing biomolecules to achieve this goal are called biosensors. Over the last half century researchers have developed dozens of different biosensor approaches. In this chapter we analyze recent advances in the biosensing field aiming at adapting these to the problem of continuous molecular monitoring in complex sample streams, and how the merging of these sensors with lab-on-a-chip technologies would be beneficial to both. To do so we discuss (1) the components that comprise a biosensor, (2) the challenges associated with continuous molecular monitoring in complex sample streams, (3) how different sensing strategies deal with (or fail to deal with) these challenges, and (4) the implementation of these technologies into lab-on-a-chip architectures.
Collapse
Affiliation(s)
- Andrea Idili
- Department of Chemistry and Biochemistry, University of California, Santa Barbara, CA, United States; Department of Chemical Science and Technologies, University of Rome, Tor Vergata, Rome, Italy
| | - Helena Montón
- Department of Chemistry and Biochemistry, University of California, Santa Barbara, CA, United States
| | | | - Bergoi Ibarlucea
- Institute for Materials Science and Max Bergmann Center for Biomaterials, Technische Universität Dresden, Dresden, Germany; Center for Advancing Electronics Dresden (CFAED), Technische Universität Dresden, Dresden, Germany
| | - Gianaurelio Cuniberti
- Institute for Materials Science and Max Bergmann Center for Biomaterials, Technische Universität Dresden, Dresden, Germany; Center for Advancing Electronics Dresden (CFAED), Technische Universität Dresden, Dresden, Germany
| | - Oliver G Schmidt
- Institute for Integrative Nanosciences, Leibniz IFW Dresden, Dresden, Germany; Research Center for Materials, Architectures and Integration of Nanomembranes (MAIN), Chemnitz, Germany; School of Science, TU Dresden, Dresden, Germany
| | - Kevin W Plaxco
- Department of Chemistry and Biochemistry, University of California, Santa Barbara, CA, United States; Interdepartmental Program in Biomolecular Science and Engineering University of California, Santa Barbara, CA, United States
| | - Claudio Parolo
- Department of Chemistry and Biochemistry, University of California, Santa Barbara, CA, United States; Barcelona Institute for Global Health (ISGlobal) Hospital Clínic, Barcelona, Spain.
| |
Collapse
|
2
|
Mandal D, Biswas S, Chowdhury A, De D, Tiwary CS, Gupta AN, Singh T, Chandra A. Hierarchical cage-frame type nanostructure of CeO 2 for bio sensing applications: from glucose to protein detection. NANOTECHNOLOGY 2021; 32:025504. [PMID: 32932238 DOI: 10.1088/1361-6528/abb8a8] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Self-assembled hierarchical nanostructures are slowly superseding their conventional counterparts for use in biosensors. These morphologies show high surface area with tunable porosity and packing density. Modulating the interfacial interactions and subsequent particle assembly occurring at the water-and-oil interface in inverse miniemulsions, are amongst the best strategies to stabilize various type of hollow nanostructures. The paper presents a successful protocol to obtain CeO2 hollow structures based biosensors that are useful for glucose to protein sensing. The fabricated glucose sensor is able to deliver high sensitivity (0.495 μA cm-2 nM-1), low detection limit (6.46 nM) and wide linear range (0 nM to 600 nM). CeO2 based bioelectrode can also be considered as a suitable candidate for protein sensors. It can detect protein concentrations varying from 0 to 30 µM, which is similar or higher than most reports in the literature. The limit of detection (LOD) for protein was ∼0.04 µM. Therefore, the hollow CeO2 electrodes, with excellent reproducibility, stability and repeatability, open a new area of application for cage-frame type particles.
Collapse
Affiliation(s)
- Debabrata Mandal
- School of Nanoscience and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
- Department of Physics, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
- School of Energy Science and Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Sudipta Biswas
- Department of Physics, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Ananya Chowdhury
- Department of Physics, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Debajyoti De
- Department of Physics, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Chandra Sekar Tiwary
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Amar Nath Gupta
- School of Nanoscience and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Trilok Singh
- School of Energy Science and Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Amreesh Chandra
- School of Nanoscience and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
- Department of Physics, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| |
Collapse
|