1
|
Ma L, Hou W, Ji Z, Sun Z, Li M, Lian B. Wearable Electrochemical Sensor for Sweat-Based Potassium Ion and Glucose Detection in Exercise Health Monitoring. ChemistryOpen 2024; 13:e202300217. [PMID: 38441499 PMCID: PMC11319218 DOI: 10.1002/open.202300217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 01/30/2024] [Indexed: 08/15/2024] Open
Abstract
The increasing prevalence of wearable devices has sparked a growing interest in real-time health monitoring and physiological parameter tracking. This study focuses on the development of a cost-effective sweat analysis device, utilizing microfluidic technology and selective electrochemical electrodes for non-invasive monitoring of glucose and potassium ions. The device, through real-time monitoring of glucose and potassium ion levels in sweat during physical activity, issues a warning signal when reaching experimentally set thresholds (K+ concentration at 7.5 mM, glucose concentrations at 60 μM and 120 μM). This alerts users to potential dehydration and hypoglycemic conditions. Through the integration of microfluidic devices and precise electrochemical analysis techniques, the device enables accurate and real-time monitoring of glucose and potassium ions in sweat. This advancement in wearable technology holds significant potential for personalized health management and preventive care, promoting overall well-being, and optimizing performance during physical activities.
Collapse
Affiliation(s)
- Lei Ma
- Department School of Information Science and TechnologyNantong University 9#Seyuan road, Chongchuan districtNantongChina
| | - Wenhao Hou
- Department School of Information Science and TechnologyNantong University 9#Seyuan road, Chongchuan districtNantongChina
| | - Zhi Ji
- Department School of Information Science and TechnologyNantong University 9#Seyuan road, Chongchuan districtNantongChina
| | - Ziheng Sun
- Department School of Information Science and TechnologyNantong University 9#Seyuan road, Chongchuan districtNantongChina
| | - Muxi Li
- Department School of Information Science and TechnologyNantong University 9#Seyuan road, Chongchuan districtNantongChina
| | - Bolin Lian
- Department School of Life scienceNantong University 9#Seyuan road, Chongchuan districtNantongChina
| |
Collapse
|
2
|
Ferreira R, Silva AP, Nunes-Pereira J. Current On-Skin Flexible Sensors, Materials, Manufacturing Approaches, and Study Trends for Health Monitoring: A Review. ACS Sens 2024; 9:1104-1133. [PMID: 38394033 PMCID: PMC10964246 DOI: 10.1021/acssensors.3c02555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 01/17/2024] [Accepted: 02/07/2024] [Indexed: 02/25/2024]
Abstract
Due to an ever-increasing amount of the population focusing more on their personal health, thanks to rising living standards, there is a pressing need to improve personal healthcare devices. These devices presently require laborious, time-consuming, and convoluted procedures that heavily rely on cumbersome equipment, causing discomfort and pain for the patients during invasive methods such as sample-gathering, blood sampling, and other traditional benchtop techniques. The solution lies in the development of new flexible sensors with temperature, humidity, strain, pressure, and sweat detection and monitoring capabilities, mimicking some of the sensory capabilities of the skin. In this review, a comprehensive presentation of the themes regarding flexible sensors, chosen materials, manufacturing processes, and trends was made. It was concluded that carbon-based composite materials, along with graphene and its derivates, have garnered significant interest due to their electromechanical stability, extraordinary electrical conductivity, high specific surface area, variety, and relatively low cost.
Collapse
Affiliation(s)
- Rodrigo
G. Ferreira
- C-MAST, Centre for Mechanical and Aerospace
Science and Technologies, Universidade da
Beira Interior, Rua Marquês d’Ávila e Bolama, 6201-001 Covilhã, Portugal
| | - Abílio P. Silva
- C-MAST, Centre for Mechanical and Aerospace
Science and Technologies, Universidade da
Beira Interior, Rua Marquês d’Ávila e Bolama, 6201-001 Covilhã, Portugal
| | - João Nunes-Pereira
- C-MAST, Centre for Mechanical and Aerospace
Science and Technologies, Universidade da
Beira Interior, Rua Marquês d’Ávila e Bolama, 6201-001 Covilhã, Portugal
| |
Collapse
|
3
|
Purvis S, Gion T. Fluid Status Vulnerability in Older Adults. JOURNAL OF INFUSION NURSING 2024; 47:49-53. [PMID: 38211615 DOI: 10.1097/nan.0000000000000534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2024]
Abstract
There is a growing body of evidence about physiological changes with age that impact fluid and electrolyte balance. It is important that infusion nurses have knowledge in managing care for geriatric patients so they can identify these changes when they are exhibited. Knowing how to minimize the effect of these changes on the health of older adults is critical. The infusion nurse with knowledge of geriatric-focused care can avoid complications and critical illness in older adults. In addition, it is important to provide specific patient education that is grounded in geriatric best practices. This information will assist older adults to better protect themselves from dehydration, kidney injury, and other complications associated with fluid balance, such as delirium. This article reviews the literature on specific changes with aging that predispose older adults to adverse complications with fluid imbalance. New technology in geriatrics that can improve management of fluid status, such as dehydration and electrolyte monitors, are also discussed. This review included searches of the Medline®/PubMed® Database using MeSH terms (National Library of Medicine). Search terms included the following: aging-biological; aging kidney; water-electrolyte imbalance; dehydration; hypo-hypernatremia; hypo-hyperkalemia; delirium; wearable technology; and hydration monitors.
Collapse
Affiliation(s)
- Suzanne Purvis
- Confidence in Aging, LLC, Alexandria, Virginia (Purvis); Confidence in Aging, LLC, Madison, Wisconsin (Gion)
- Suzanne Purvis, DNP, APRN, GCNS-BC, FCNS, brings over 20 years' experience working in health care systems as a clinical nurse specialist in geriatrics to her current business, Confidence in Aging, LLC. The primary mission of Confidence in Aging is to help individuals, schools, communities, and businesses to better understand and manage aging. Suzanne has a doctorate in nursing from the University of Minnesota. She has won several awards in clinical excellence and in health care education and has achieved fellowship in the National Association of Clinical Nurse Specialists. Additionally, she is published on a variety of health care topics, including as contributing author in the current edition of the Adult-Gerontology Certification Review (ANCC, Springer Publishing, 2021). Suzanne's passion is to help everyone embrace and manage aging as a unique life phase
- Terry Gion, DNP, RN, CRRN, NE-BC, has over 40 years of experience working in the health care system. She has been a clinical nurse specialist in acute rehabilitation, nurse leader in medical and procedural nursing, and a consultant in various health care-related businesses. Terry has a doctorate of nursing from Concordia University. She has won various awards in clinical excellence and nursing leadership and has held board positions for professional organizations. She is published on clinical and leadership health care topics. Terry's passion is to provide evidence-based educational materials that can help others understand and manage their health and health care needs
| | - Terry Gion
- Confidence in Aging, LLC, Alexandria, Virginia (Purvis); Confidence in Aging, LLC, Madison, Wisconsin (Gion)
- Suzanne Purvis, DNP, APRN, GCNS-BC, FCNS, brings over 20 years' experience working in health care systems as a clinical nurse specialist in geriatrics to her current business, Confidence in Aging, LLC. The primary mission of Confidence in Aging is to help individuals, schools, communities, and businesses to better understand and manage aging. Suzanne has a doctorate in nursing from the University of Minnesota. She has won several awards in clinical excellence and in health care education and has achieved fellowship in the National Association of Clinical Nurse Specialists. Additionally, she is published on a variety of health care topics, including as contributing author in the current edition of the Adult-Gerontology Certification Review (ANCC, Springer Publishing, 2021). Suzanne's passion is to help everyone embrace and manage aging as a unique life phase
- Terry Gion, DNP, RN, CRRN, NE-BC, has over 40 years of experience working in the health care system. She has been a clinical nurse specialist in acute rehabilitation, nurse leader in medical and procedural nursing, and a consultant in various health care-related businesses. Terry has a doctorate of nursing from Concordia University. She has won various awards in clinical excellence and nursing leadership and has held board positions for professional organizations. She is published on clinical and leadership health care topics. Terry's passion is to provide evidence-based educational materials that can help others understand and manage their health and health care needs
| |
Collapse
|
4
|
Rodin D, Shapiro Y, Pinhasov A, Kreinin A, Kirby M. An accurate wearable hydration sensor: Real-world evaluation of practical use. PLoS One 2022; 17:e0272646. [PMID: 36001536 PMCID: PMC9401113 DOI: 10.1371/journal.pone.0272646] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Accepted: 07/22/2022] [Indexed: 11/18/2022] Open
Abstract
A wearable body hydration sensor employing photoplethysmographic and galvanic biosensors was field evaluated using 240 human participants with equal numbers of men and women volunteers. Monitoring of water mass loss due to perspiration was performed by medical balance measurements following one of two different treadmill physical exercise regimens over 90 minutes in 15-minute intervals with intervening 10-minute rest periods. Participants wore two different models of the dehydration body monitor device mated to commercially-available smartwatches (Samsung Gear S2 and Samsung Gear Fit2). Device output was recorded by Bluetooth wireless link to a standard smartphone in 20-second blocks. Comparison of the devices with the standard measurement method (change in body mass measured by medical balance) indicated very close agreement between changes in body water mass and device output (percent normalized mean root square error averaged approximately 2% for all participants). Bland-Altman analyses of method agreement indicated that <5% of participant values fell outside of the 95% confidence interval limits of agreement and all measured value differences were normally distributed around the line of equality. The results of this first-ever field trial of a practical, wearable hydration monitor suggests that this device will be a reliable tool to aid in geriatric hydration monitoring and physical training scenarios.
Collapse
Affiliation(s)
- Dmitry Rodin
- Institute for Personalized and Translational Medicine, Ariel University, Ariel, Israel
| | - Yair Shapiro
- Department of Health Administration and Adelson School of Medicine, Ariel University, Ariel, Israel
| | - Albert Pinhasov
- Department of Molecular Biology and Adelson School of Medicine, Ariel University, Ariel, Israel
| | - Anatoly Kreinin
- Department of Molecular Biology and Adelson School of Medicine, Ariel University, Ariel, Israel
| | - Michael Kirby
- Department of Molecular Biology and Adelson School of Medicine, Ariel University, Ariel, Israel
- * E-mail:
| |
Collapse
|
5
|
Steijlen ASM, Jansen KMB, Bastemeijer J, French PJ, Bossche A. Low-Cost Wearable Fluidic Sweat Collection Patch for Continuous Analyte Monitoring and Offline Analysis. Anal Chem 2022; 94:6893-6901. [PMID: 35486709 PMCID: PMC9096792 DOI: 10.1021/acs.analchem.2c01052] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Sweat sensors allow for new unobtrusive ways to continuously monitor an athlete's performance and health status. Significant advances have been made in the optimization of sensitivity, selectivity, and durability of electrochemical sweat sensors. However, comparing the in situ performance of these sensors in detail remains challenging because standardized sweat measurement methods to validate sweat sensors in a physiological setting do not yet exist. Current collection methods, such as the absorbent patch technique, are prone to contamination and are labor-intensive, which limits the number of samples that can be collected over time for offline reference measurements. We present an easy-to-fabricate sweat collection system that allows for continuous electrochemical monitoring, as well as chronological sampling of sweat for offline analysis. The patch consists of an analysis chamber hosting a conductivity sensor and a sequence of 5 to 10 reservoirs that contain level indicators that monitor the filling speed. After testing the performance of the patch in the laboratory, elaborate physiological validation experiments (3 patch locations, 6 participants) were executed. The continuous sweat conductivity measurements were compared with laboratory [Na+] and [Cl-] measurements of the samples, and a strong linear relationship (R2 = 0.97) was found. Furthermore, sweat rate derived from ventilated capsule measurement at the three locations was compared with patch filling speed and continuous conductivity readings. As expected from the literature, sweat conductivity was linearly related to sweat rate as well. In short, a successfully validated sweat collection patch is presented that enables sensor developers to systematically validate novel sweat sensors in a physiological setting.
Collapse
Affiliation(s)
- Annemarijn S M Steijlen
- Faculty of Electrical Engineering, Mathematics & Computer Science, Delft University of Technology, Mekelweg 4, Delft 2628 CD, The Netherlands
| | - Kaspar M B Jansen
- Faculty of Industrial Design Engineering, Delft University of Technology, Landbergstraat 15, Delft 2628 CE, The Netherlands
| | - Jeroen Bastemeijer
- Faculty of Electrical Engineering, Mathematics & Computer Science, Delft University of Technology, Mekelweg 4, Delft 2628 CD, The Netherlands
| | - Paddy J French
- Faculty of Electrical Engineering, Mathematics & Computer Science, Delft University of Technology, Mekelweg 4, Delft 2628 CD, The Netherlands
| | - Andre Bossche
- Faculty of Electrical Engineering, Mathematics & Computer Science, Delft University of Technology, Mekelweg 4, Delft 2628 CD, The Netherlands
| |
Collapse
|
6
|
El-Naggar ME, Abu Ali OA, Saleh DI, Abu-Saied MA, Khattab TA. Preparation of green and sustainable colorimetric cotton assay using natural anthocyanins for sweat sensing. Int J Biol Macromol 2021; 190:894-903. [PMID: 34534584 DOI: 10.1016/j.ijbiomac.2021.09.049] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 08/25/2021] [Accepted: 09/09/2021] [Indexed: 12/20/2022]
Abstract
Herein, we develop a novel smart cotton swab as a diagnostic assay for onsite monitoring of sweat pH changes toward potential applications in monitoring human healthcare and drug exam. Anthocyanin (Ac) can be extracted from Brassica oleracea var. capitata f. rubra using a simple procedure. Then, it can be used as a direct dye into cotton fibers using potash alum as mordant (M) to fix the anthocyanin dye onto the surface of the cotton fabric (Cot). This was monitored by generating mordant/anthocyanin nanoparticles (MAcNPs) onto the fabric surface. The cotton sensor assay demonstrated colorimetric changes in the ultraviolet-visible absorbance spectral analysis associated with a blueshift from 588 to 422 nm with increasing the pH of a perspiration simulant fluid. The biochromic performance of the dyed cotton diagnostic assay depended essentially on the halochromic activity of the anthocyanin spectroscopic probe to demonstrate a color change from pink to green due to intramolecular charge transfer occurring on the anthocyanin chromophore. After dyeing, no significant defects were detected in air-permeability and bend length. High colorfastness was investigated for the dyed cotton fabrics.
Collapse
Affiliation(s)
- Mehrez E El-Naggar
- Textile Research Division, National Research Center (Affiliation ID: 60014618), Dokki, Cairo, Egypt.
| | - Ola A Abu Ali
- Department of Chemistry, College of Science, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia
| | - Dalia I Saleh
- Department of Chemistry, College of Science, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia
| | - M A Abu-Saied
- Polymeric Materials Research Department, Advanced Technology and New Materials Research Institute, City of Scientific Research and Technological Applications (SRTA-CITY), New Borg El-Arab City, 21934, Alexandria, Egypt
| | - Tawfik A Khattab
- Textile Research Division, National Research Center (Affiliation ID: 60014618), Dokki, Cairo, Egypt
| |
Collapse
|
7
|
Ghaffari R, Yang DS, Kim J, Mansour A, Wright JA, Model JB, Wright DE, Rogers JA, Ray TR. State of Sweat: Emerging Wearable Systems for Real-Time, Noninvasive Sweat Sensing and Analytics. ACS Sens 2021; 6:2787-2801. [PMID: 34351759 DOI: 10.1021/acssensors.1c01133] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Skin-interfaced wearable systems with integrated colorimetric assays, microfluidic channels, and electrochemical sensors offer powerful capabilities for noninvasive, real-time sweat analysis. This Perspective details recent progress in the development and translation of novel wearable sensors for personalized assessment of sweat dynamics and biomarkers, with precise sampling and real-time analysis. Sensor accuracy, system ruggedness, and large-scale deployment in remote environments represent key opportunity areas, enabling broad deployment in the context of field studies, clinical trials, and recent commercialization. On-body measurements in these contexts show good agreement compared to conventional laboratory-based sweat analysis approaches. These device demonstrations highlight the utility of biochemical sensing platforms for personalized assessment of performance, wellness, and health across a broad range of applications.
Collapse
Affiliation(s)
- Roozbeh Ghaffari
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - Da Som Yang
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
| | - Joohee Kim
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
| | - Amer Mansour
- Division of Biological Sciences, The University of Chicago, Chicago, Illinois 60637, United States
| | - John A. Wright
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - Jeffrey B. Model
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - Donald E. Wright
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
| | - John A. Rogers
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, Illinois 60202, United States
- Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60202, United States
- Epicore Biosystems, Inc., Cambridge, Massachusetts 02139, United States
- Departments of Materials Science and Engineering, Mechanical Engineering, Electrical and Computer Engineering, and Chemistry, Northwestern University, Evanston, Illinois 60202, United States
- Department of Neurological Surgery, Northwestern University Feinberg School of Medicine, Chicago, Illinois 60611, United States
| | - Tyler R. Ray
- Department of Mechanical Engineering, University of Hawai’i at Ma̅noa, Honolulu, Hawaii 96822, United States
- Department of Cell and Molecular Biology, John A. Burns School of Medicine, University of Hawai’i at Ma̅noa, Honolulu, Hawaii 96813, United States
| |
Collapse
|
8
|
Al-Qahtani SD, Azher OA, Felaly R, Subaihi A, Alkabli J, Alaysuy O, El-Metwaly NM. Development of sponge-like cellulose colorimetric swab immobilized with anthocyanin from red-cabbage for sweat monitoring. Int J Biol Macromol 2021; 182:2037-2047. [PMID: 34087294 DOI: 10.1016/j.ijbiomac.2021.05.201] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 05/27/2021] [Accepted: 05/30/2021] [Indexed: 12/30/2022]
Abstract
Novel sponge-like biochromic swab was developed via immobilization of natural anthocyanin (Cy) biomolecular probe into microporous cellulose aerogel. The current biosensor is characterized with simple preparation, environmentally-friendly, biocompatibility, biodegradability, flexibility, portability and reversibility. This biochromic sponge-like aerogel detector displayed a color change from pink to green-yellow in response to the biochemical changes occurs to sweat. This could be ascribed to intramolecular charge transfer occurs to the molecular system of Cy. Thus, the anthocyanin probe displayed colorimetric variations in UV-Vis absorption spectra via a blue shifting from 620 to 529 nm when raising the pH value of the prepared mimic sweat solution. Natural pH sensitive anthocyanin spectroscopic probe was extracted from red-cabbage plant, characterized by HPLC, and encapsulated into microporous cellulose. The microporous sponge-like cellulose swab was prepared by activating wood pulp utilizing phosphoric acid, and then subjected to freeze-drying. This anthocyanin probe is highly soluble in water. Thus, it was encapsulated as a direct dye into cellulose substrate during the freeze-drying process. To allow a better fixation of this water-soluble anthocyanin probe to the cellulose substrate, potash alum was added to the freeze-dried mixture to act as a fixing agent or mordant (M) generating Cy/M coordination complex. The produced Cy/M nanoparticles (NPs) were explored by transmission electron microscopy (TEM). The morphological features of the generated aerogels were investigated by scan electron microscope (SEM), energy-dispersive X-ray (EDX) spectra, and Fourier-transform infrared spectra (FT-IR). The cytotoxicity of the prepared aerogel-based biosensor was also evaluated. The naked-eye colorimetric changes were studied by exploring color strength, UV-Vis spectra and CIE Lab colorimetric coordinates.
Collapse
Affiliation(s)
- Salhah D Al-Qahtani
- Department of Chemistry, College of Science, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia
| | - Omer A Azher
- Department of Laboratory Medicine, Faculty of Applied Biomedical Sciences, Al-Baha University, Saudi Arabia
| | - Rasha Felaly
- Department of Chemistry, Faculty of Applied Science, Umm-Al-Qura University, Makkah, Saudi Arabia
| | - Abdu Subaihi
- Department of Chemistry, University College in Al-Qunfudah, Umm-Al-Qura University, Saudi Arabia
| | - J Alkabli
- Department of Chemistry, College of Science and Arts-Alkamil, University of Jeddah, Jeddah, 23218, Saudi Arabia
| | - Omaymah Alaysuy
- Department of Chemistry, College of Science, University of Tabuk, Saudi Arabia
| | - Nashwa M El-Metwaly
- Department of Chemistry, Faculty of Applied Science, Umm-Al-Qura University, Makkah, Saudi Arabia; Department of Chemistry, Faculty of Science, Mansoura University, El-Gomhoria Street, Egypt.
| |
Collapse
|
9
|
Yin S, Liu X, Kaji T, Nishina Y, Miyake T. Fiber-crafted biofuel cell bracelet for wearable electronics. Biosens Bioelectron 2021; 179:113107. [PMID: 33640657 DOI: 10.1016/j.bios.2021.113107] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 02/16/2021] [Accepted: 02/17/2021] [Indexed: 12/19/2022]
Abstract
Wearable devices that generate power using sweat have garnered much attention in the field of skin electronics. These devices require high performance with a small volume and low production rate of sweat by living organisms. Here we demonstrate a high-power biofuel cell bracelet based on the lactate in human sweat. The biofuel cell was developed by using a lactate oxidase/osmium-based mediator/carbon nanotube fiber for lactate oxidation and a bilirubin oxidase/carbon nanotube fiber for oxygen reduction; the fibers were woven into a hydrophilic supportive textile for sweat storage. The storage textile was sandwiched between a hydrophobic textile for sweat absorption from the skin and a hydrophilic textile for water evaporation to improve sweat collection. The performance of the layered cell was 74 μW at 0.39 V in 20 mM artificial sweat lactate, and its performance was maintained at over 80% for 12 h. Furthermore, we demonstrated a series-connection between anode/cathode fibers by tying them up to wrap the bracelet-type biofuel cell on the wrist. The booster six-cell bracelet generated power at 2.0 V that is sufficient for operating digital wrist watches.
Collapse
Affiliation(s)
- Sijie Yin
- Graduate School of Information, Production and Systems, Waseda University, 2-7 Hibikino, Wakamatsu, Kitakyushu, Fukuoka, 808-0135, Japan
| | - Xiaohan Liu
- Graduate School of Information, Production and Systems, Waseda University, 2-7 Hibikino, Wakamatsu, Kitakyushu, Fukuoka, 808-0135, Japan
| | - Tatsuya Kaji
- Graduate School of Natural Science and Technology, Okayama University, Tsushimanaka, Kita-ku, Okayama, 700-8530, Japan
| | - Yuta Nishina
- Graduate School of Natural Science and Technology, Okayama University, Tsushimanaka, Kita-ku, Okayama, 700-8530, Japan
| | - Takeo Miyake
- Graduate School of Information, Production and Systems, Waseda University, 2-7 Hibikino, Wakamatsu, Kitakyushu, Fukuoka, 808-0135, Japan; PRESTO, Japan Science and Technology Agency, 4-1-8 Honcho, Kawaguchi, Saitama, 332-0012, Japan.
| |
Collapse
|