1
|
Hu W, Yie KHR, Liu C, Zhu J, Huang Z, Zhu B, Zheng D, Yang B, Huang B, Yao L, Liu J, Shen X, Deng Z. Improving the valence self-reversible conversion of cerium nanoparticles on titanium implants by lanthanum doping to enhance ROS elimination and osteogenesis. Dent Mater 2022; 38:1362-1375. [PMID: 35752471 DOI: 10.1016/j.dental.2022.06.014] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 05/04/2022] [Accepted: 06/05/2022] [Indexed: 11/29/2022]
Abstract
Equipped with anti-oxidative properties, cerium oxide nanoparticles (CNPs) are gradually being adopted over the years in the field of oxidative stress research. However, the effects of CNPs may be diminished when under the influence of prolonged and substantially elevated levels of oxidative stress. Therefore, it is imperative to enhance the efficacy of CNPs to resist oxidative stress. In this study, our approach involves the fabrication of titanium surface CNPs coatings doped with different concentrations of lanthanum ions (La3+) and the investigation of their local anti-oxidative stress potential. The physicochemical characterization showed that the La-CNPs groups had a substantial increase in the generation of oxygen vacancies within the CNPs structure with the increase of La doping concentration. In vitro findings proofed that the cytocompatibility of different La-CNPs coatings showed a trend of increasing first and then decreasing with the increase of La doping concentration under oxidative stress microenvironment. Among these groups, the 30 % La-CNPs group presented the best cell proliferation and osteogenic differentiation which could activate the FoxO1 pathway, then upregulated the expression of SOD1 and CAT, and finally resulted in the inhibition of ROS production. In vivo results further confirmed that the 30 % La-CNPs group showed significant osteogenic effects in two rat models (osteoporosis and diabetes models). In conclusion, we believe that the 30 % La-CNPs coating holds promising potential for its implant applications in patients with oxidative stress-related diseases.
Collapse
Affiliation(s)
- Wenjia Hu
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China
| | - Kendrick Hii Ru Yie
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China
| | - Chongxing Liu
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China
| | - Jinlei Zhu
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China
| | - Zhuo Huang
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China
| | - Bingbing Zhu
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China
| | - Dongyang Zheng
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China
| | - Bingqian Yang
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China
| | - Benheng Huang
- School and Hospital of Stomatology, Lanzhou University, Lanzhou 730000, China
| | - Lili Yao
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China
| | - Jinsong Liu
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China.
| | - Xinkun Shen
- Science and Education Division, The Third Affiliated Hospital of Wenzhou Medical University (Ruian People's Hospital), Wenzhou 325016, China.
| | - Zhennan Deng
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China.
| |
Collapse
|