1
|
Yang D, Hu Q, Zhao S, Hu X, Gao X, Dai F, Zheng Y, Yang Y, Cheng Y. An optofluidic system for the concentration gradient screening of oocyte protection drugs. Talanta 2024; 278:126472. [PMID: 38924991 DOI: 10.1016/j.talanta.2024.126472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2024] [Revised: 06/17/2024] [Accepted: 06/23/2024] [Indexed: 06/28/2024]
Abstract
Oocytes protective drug screening is essential for the treatment of reproductive diseases. However, few studies construct the oocyte in vitro drug screening microfluidic systems because of their enormous size, scarcity, and sensitivity to the culture environment. Here, we present an optofluidic system for oocyte drug screening and state analysis. The system consists of two parts: an open-top drug screening microfluidic chip and an optical Fourier filter analysis part. The open-top microfluidic chip anchors single oocyte with hydrogel and allows nutrient and gas environment updating which is essential for oocyte culturing. The optical filter analysis part is used to accurately analyse the status of oocytes. Based on this system, we found that fluorene-9-bisphenol (BHPF) damaged the oocyte spindle in a dose-dependent manner, a high dose of melatonin (10-3 M) effectively reduces the percentage of abnormally arranged chromosomes of oocytes exposed to 40 μM BHPF. This optofluidic system shows great promise for the culture of oocytes and demonstrates the robust ability for convenient multi-concentration oocytes drug screening. This technology may benefit further biomedicine and reproductive toxicology applications in the lab on a chip community.
Collapse
Affiliation(s)
- Dongyong Yang
- Department of Obstetrics and Gynecology, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Qinghao Hu
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital of Wuhan University, Wuhan, 430072, China; Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, School of Physics & Technology, Wuhan University, Wuhan, 430072, China; Shenzhen Research Institute, Wuhan University, Shenzhen, 518000, China
| | - Shukun Zhao
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital of Wuhan University, Wuhan, 430072, China; Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, School of Physics & Technology, Wuhan University, Wuhan, 430072, China; Shenzhen Research Institute, Wuhan University, Shenzhen, 518000, China
| | - Xuejia Hu
- Department of Electronic Engineering, School of Electronic Science and Engineering, Xiamen University, Xiamen, 361005, China
| | - Xiaoqi Gao
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital of Wuhan University, Wuhan, 430072, China; Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, School of Physics & Technology, Wuhan University, Wuhan, 430072, China; Shenzhen Research Institute, Wuhan University, Shenzhen, 518000, China
| | - Fangfang Dai
- Department of Obstetrics and Gynecology, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Yajing Zheng
- Department of Obstetrics and Gynecology, Renmin Hospital of Wuhan University, Wuhan, 430060, China
| | - Yi Yang
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital of Wuhan University, Wuhan, 430072, China; Key Laboratory of Artificial Micro/Nano Structure of Ministry of Education, School of Physics & Technology, Wuhan University, Wuhan, 430072, China; Shenzhen Research Institute, Wuhan University, Shenzhen, 518000, China.
| | - Yanxiang Cheng
- Department of Obstetrics and Gynecology, Renmin Hospital of Wuhan University, Wuhan, 430060, China.
| |
Collapse
|
2
|
Li Z, Li D, Zhang M, Jin Y, Xu Q, Yang H, Sun Y, Pu X, Li L, Zhang Y. Large dynamic range dual-mode pH sensors via dye-doped ionic liquid fiber optofluidic lasers. Analyst 2023; 148:5050-5059. [PMID: 37668015 DOI: 10.1039/d3an01156a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/06/2023]
Abstract
We report a fiber optofluidic laser (FOFL) using an RhB-doped ionic liquid (BmimPF6) as the gain medium and explore its application for large dynamic range highly sensitive pH sensing. Due to the high Q-factor of the FOFL and the unique merits of BmimPF6, lasing emission presents a threshold of only 0.61 μJ mm-1. Particularly, lasing emission behaviors are strongly dependent on the pH value of the gain medium, i.e., in the pH range 4.28-6.37, the lasing central wavelength blue-shifts monotonically with a sensitivity as high as 5.02 nm per pH unit, which we attribute to the conversion of the cationic form of RhB to the zwitterionic form caused by the deprotonation of the COOH group. Under alkaline conditions (pH 7.20-11.17), the lasing emission intensity exhibits a significant decrease and the corresponding lasing central wavelength is also blue-shifted due to the solvent effect. The sensitivity based on the wavelength shift is 3.03 nm per pH unit, which is 4-fold higher than that of fluorescence-based sensing, while the sensitivity based on the variation of the lasing emission intensity is almost three orders of magnitude higher than that of fluorescence-based sensing. Our work presents a novel dual sensing paradigm in response to different pH conditions, which can greatly improve the reliability and discrimination of pH sensing.
Collapse
Affiliation(s)
- Zhi Li
- Department of Physics, Yunnan University, Kunming 650091, China.
| | - Dongyang Li
- Department of Physics, Yunnan University, Kunming 650091, China.
| | - Mengda Zhang
- Department of Physics, Yunnan University, Kunming 650091, China.
| | - Yingxia Jin
- School of Materials and Energy, Yunnan University, Kunming 650091, China
| | - Qingbo Xu
- Department of Physics, Yunnan University, Kunming 650091, China.
| | - Haiyan Yang
- School of Architectural Engineering, Kunming Metallurgy College, Kunming 650033, China
| | - Yuze Sun
- Department of Electrical Engineering, The University of Texas at Arlington, Arlington, TX 76019, USA
| | - Xiaoyun Pu
- Department of Physics, Yunnan University, Kunming 650091, China.
| | - Liang Li
- School of Materials and Energy, Yunnan University, Kunming 650091, China
| | - Yuanxian Zhang
- Department of Physics, Yunnan University, Kunming 650091, China.
| |
Collapse
|
3
|
Chen L, Yu L, Liu Y, Xu H, Li W, Wang F, Zhu J, Yi K, Ma L, Xiao H, Zhou F, Chen M, Cheng Y, Wang F, Zhu C, Xiao X, Yang Y. Valve-Adjustable Optofluidic Bio-Imaging Platform for Progressive Stenosis Investigation. ACS Sens 2023; 8:3104-3115. [PMID: 37477650 DOI: 10.1021/acssensors.3c00754] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/22/2023]
Abstract
The clinical evidence has proven that valvular stenosis is closely related to many vascular diseases, which attracts great academic attention to the corresponding pathological mechanisms. The investigation is expected to benefit from the further development of an in vitro model that is tunable for bio-mimicking progressive valvular stenosis and enables accurate optical recognition in complex blood flow. Here, we develop a valve-adjustable optofluidic bio-imaging recognition platform to fulfill it. Specifically, the bionic valve was designed with in situ soft membrane, and the internal air-pressure chamber could be regulated from the inside out to bio-mimic progressive valvular stenosis. The developed imaging algorithm enhances the recognition of optical details in blood flow imaging and allows for quantitative analysis. In a prospective clinical study, we examined the effect of progressive valvular stenosis on hemodynamics within the typical physiological range of veins by this way, where the inhomogeneity and local enhancement effect in the altered blood flow field were precisely described and the optical differences were quantified. The effectiveness and consistency of the results were further validated through statistical analysis. In addition, we tested it on fluorescence and noticed its good performance in fluorescent tracing of the clotting process. In virtue of theses merits, this system should be able to contribute to mechanism investigation, pharmaceutical development, and therapeutics of valvular stenosis-related diseases.
Collapse
Affiliation(s)
- Longfei Chen
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital of Wuhan University, Key Laboratory of Artificial Micro- and Nano- Structures of Ministry of Education, School of Physics & technology, Wuhan University, Wuhan 430072, China
- Shenzhen Research Institute, Wuhan University, Shenzhen 518000, China
| | - Le Yu
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital of Wuhan University, Key Laboratory of Artificial Micro- and Nano- Structures of Ministry of Education, School of Physics & technology, Wuhan University, Wuhan 430072, China
| | - Yantong Liu
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital of Wuhan University, Key Laboratory of Artificial Micro- and Nano- Structures of Ministry of Education, School of Physics & technology, Wuhan University, Wuhan 430072, China
| | - Hongshan Xu
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital of Wuhan University, Key Laboratory of Artificial Micro- and Nano- Structures of Ministry of Education, School of Physics & technology, Wuhan University, Wuhan 430072, China
| | - Wei Li
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital of Wuhan University, Key Laboratory of Artificial Micro- and Nano- Structures of Ministry of Education, School of Physics & technology, Wuhan University, Wuhan 430072, China
| | - Fang Wang
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital of Wuhan University, Key Laboratory of Artificial Micro- and Nano- Structures of Ministry of Education, School of Physics & technology, Wuhan University, Wuhan 430072, China
| | - Jiaomeng Zhu
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital of Wuhan University, Key Laboratory of Artificial Micro- and Nano- Structures of Ministry of Education, School of Physics & technology, Wuhan University, Wuhan 430072, China
| | - Kezhen Yi
- Department of Laboratory Medicine, Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan 430071, China
| | - Linlu Ma
- Department of Hematology, Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan 430071, China
| | - Hui Xiao
- Department of Hematology, Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan 430071, China
| | - Fuling Zhou
- Department of Hematology, Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan 430071, China
| | - Ming Chen
- Department of Blood Transfusion, Zhongnan Hospital, Wuhan University, Wuhan 430071, China
| | - Yanxiang Cheng
- School of Medicine, Renmin Hospital, Wuhan University, Wuhan 430060, China
| | - Fubing Wang
- Department of Laboratory Medicine, Zhongnan Hospital of Wuhan University, Wuhan University, Wuhan 430071, China
| | - Chengliang Zhu
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital of Wuhan University, Wuhan University, Wuhan 430072, China
| | - Xuan Xiao
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital of Wuhan University, Wuhan University, Wuhan 430072, China
| | - Yi Yang
- Department of Clinical Laboratory, Institute of Medicine and Physics, Renmin Hospital of Wuhan University, Key Laboratory of Artificial Micro- and Nano- Structures of Ministry of Education, School of Physics & technology, Wuhan University, Wuhan 430072, China
- Shenzhen Research Institute, Wuhan University, Shenzhen 518000, China
| |
Collapse
|
4
|
Chen Y, Xiong X, Chen Y, Chen L, Liu G, Xiao W, Shi J, Chen Z, Luo Y. MoS 2-Nanoflower and Nanodiamond Co-Engineered Surface Plasmon Resonance for Biosensing. BIOSENSORS 2023; 13:bios13050506. [PMID: 37232867 DOI: 10.3390/bios13050506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 04/20/2023] [Accepted: 04/26/2023] [Indexed: 05/27/2023]
Abstract
Surface plasmon resonance (SPR) based sensors play an important role in the biological and medical fields, and improving the sensitivity is a goal that has always been pursued. In this paper, a sensitivity enhancement scheme jointly employing MoS2 nanoflower (MNF) and nanodiamond (ND) to co-engineer the plasmonic surface was proposed and demonstrated. The scheme could be easily implemented via physically depositing MNF and ND overlayers on the gold surface of an SPR chip, and the overlayer could be flexibly adjusted by controlling the deposition times, thus approaching the optimal performance. The bulk RI sensitivity was enhanced from 9682 to 12,219 nm/RIU under the optimal condition that successively deposited MNF and ND 1 and 2 times. The proposed scheme was proved in an IgG immunoassay, where the sensitivity was twice enhanced compared to the traditional bare gold surface. Characterization and simulation results revealed that the improvement arose from the enhanced sensing field and increased antibody loading via the deposited MNF and ND overlayer. At the same time, the versatile surface property of NDs allowed a specifically-functionalized sensor using the standard method compatible with a gold surface. Besides, the application for pseudorabies virus detection in serum solution was also demonstrated.
Collapse
Affiliation(s)
- Yaofei Chen
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Jinan University, Guangzhou 510632, China
- Department of Optoelectronic Engineering, Jinan University, Guangzhou 510632, China
| | - Xin Xiong
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Jinan University, Guangzhou 510632, China
- Department of Optoelectronic Engineering, Jinan University, Guangzhou 510632, China
| | - Yu Chen
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Jinan University, Guangzhou 510632, China
- Department of Optoelectronic Engineering, Jinan University, Guangzhou 510632, China
| | - Lei Chen
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Jinan University, Guangzhou 510632, China
- Department of Optoelectronic Engineering, Jinan University, Guangzhou 510632, China
| | - Guishi Liu
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Jinan University, Guangzhou 510632, China
- Department of Optoelectronic Engineering, Jinan University, Guangzhou 510632, China
| | - Wei Xiao
- Department of Laboratory Medicine, Guangdong Second Provincial General Hospital, Guangzhou 510317, China
| | - Jifu Shi
- Siyuan Laboratory, Department of Physics, Jinan University, Guangzhou 510632, China
| | - Zhe Chen
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Jinan University, Guangzhou 510632, China
- Department of Optoelectronic Engineering, Jinan University, Guangzhou 510632, China
| | - Yunhan Luo
- Guangdong Provincial Key Laboratory of Optical Fiber Sensing and Communications, Jinan University, Guangzhou 510632, China
- Department of Optoelectronic Engineering, Jinan University, Guangzhou 510632, China
| |
Collapse
|
5
|
Li D, Zhou L, Yu Q, Pu X, Sun Y, Zhou Q, Zhang Y. Optical fiber optofluidic laser based on surfactant solubilization of rhodamine B gain in an aqueous solution. OPTICS EXPRESS 2022; 30:23295-23304. [PMID: 36225013 DOI: 10.1364/oe.461670] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Accepted: 06/02/2022] [Indexed: 06/16/2023]
Abstract
We report a whispering gallery mode (WGM)-based fiber optofluidic laser (FOFL), in which rhodamine B (RhB) in an aqueous surfactant solution of sodium dodecylbenzene sulfonate (SDBS) is used as the laser gain medium. Here, the role of SDBS is to scatter the RhB dye molecules to effectively prevent its self-association in the aqueous solution. Therefore, the fluorescence quantum yield of the used RhB dye is improved due to the enhanced solubilization, which results in a low lasing threshold of ∼2.2 µJ/mm2 when the concentration of SDBS aqueous solution reaches up to 20 mM, on par with or even better than most of the optofluidic dye lasers using RhB as the gain medium in an organic solution. We then establish a model of solubilization capacity of SDBS micelles, which successfully addresses the mechanisms of dye-surfactant interactions in the proposed FOFL system. We further apply this FOFL platform to the case of concentration sensing of the used SDBS, which exhibits a 2-order-of-magnitude improvement in sensitivity compared to the fluorescence measurement due to the signal amplification inherent to the lasing process. The proposed FOFL platform in combination with surfactant solubilization gain medium in an aqueous solution promises to enable chip-scale coherent light sources for various environmental and bio-chemical sensing applications.
Collapse
|
6
|
Shan H, Dai H, Chen X. Monitoring Various Bioactivities at the Molecular, Cellular, Tissue, and Organism Levels via Biological Lasers. SENSORS (BASEL, SWITZERLAND) 2022; 22:3149. [PMID: 35590841 PMCID: PMC9102053 DOI: 10.3390/s22093149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 04/16/2022] [Accepted: 04/18/2022] [Indexed: 06/15/2023]
Abstract
The laser is considered one of the greatest inventions of the 20th century. Biolasers employ high signal-to-noise ratio lasing emission rather than regular fluorescence as the sensing signal, directional out-coupling of lasing and excellent biocompatibility. Meanwhile, biolasers can also be micro-sized or smaller lasers with embedded/integrated biological materials. This article presents the progress in biolasers, focusing on the work done over the past years, including the molecular, cellular, tissue, and organism levels. Furthermore, biolasers have been utilized and explored for broad applications in biosensing, labeling, tracking, bioimaging, and biomedical development due to a number of unique advantages. Finally, we provide the possible directions of biolasers and their applications in the future.
Collapse
Affiliation(s)
- Hongrui Shan
- State Key Laboratory of Advanced Optical Communication Systems and Networks, School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240, China; (H.S.); (H.D.)
| | - Hailang Dai
- State Key Laboratory of Advanced Optical Communication Systems and Networks, School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240, China; (H.S.); (H.D.)
| | - Xianfeng Chen
- State Key Laboratory of Advanced Optical Communication Systems and Networks, School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240, China; (H.S.); (H.D.)
- Collaborative Innovation Center of Light Manipulations and Applications, Shandong Normal University, Jinan 250358, China
| |
Collapse
|