1
|
Kumar S, Kaushal JB, Lee HP. Sustainable Sensing with Paper Microfluidics: Applications in Health, Environment, and Food Safety. BIOSENSORS 2024; 14:300. [PMID: 38920604 PMCID: PMC11202065 DOI: 10.3390/bios14060300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Revised: 06/04/2024] [Accepted: 06/05/2024] [Indexed: 06/27/2024]
Abstract
This manuscript offers a concise overview of paper microfluidics, emphasizing its sustainable sensing applications in healthcare, environmental monitoring, and food safety. Researchers have developed innovative sensing platforms for detecting pathogens, pollutants, and contaminants by leveraging the paper's unique properties, such as biodegradability and affordability. These portable, low-cost sensors facilitate rapid diagnostics and on-site analysis, making them invaluable tools for resource-limited settings. This review discusses the fabrication techniques, principles, and applications of paper microfluidics, showcasing its potential to address pressing challenges and enhance human health and environmental sustainability.
Collapse
Affiliation(s)
- Sanjay Kumar
- Durham School of Architectural Engineering and Construction, University of Nebraska-Lincoln, Scott Campus, Omaha, NE 68182-0816, USA
| | - Jyoti Bala Kaushal
- Department of Biochemistry and Molecular Biology, University of Nebraska Medical Center, Omaha, NE 68198, USA
| | - Heow Pueh Lee
- Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117575, Singapore;
| |
Collapse
|
2
|
Al-Qahtani SD, Al-Senani GM. Development of toxic gas sensor from anthocyanin-embedded polycaprolactone-co-polylactic acid nanofibrous mat. Int J Biol Macromol 2024; 267:131649. [PMID: 38636751 DOI: 10.1016/j.ijbiomac.2024.131649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Revised: 04/08/2024] [Accepted: 04/14/2024] [Indexed: 04/20/2024]
Abstract
The colorless ammonia gas has been a significant intermediate in the industrial sector. However, prolonged exposure to ammonia causes harmful effects to organs or even death. Herein, an environmentally friendly solid-state ammonia sensor was developed utilizing colorimetric polycaprolactone-co-polylactic acid nanofibrous membrane. Pomegranate (Punica granatum L.) peel contains anthocyanin (ACN) as a naturally occurring spectroscopic probe. A mordant (potassium aluminum sulfate) is used to immobilize the anthocyanin direct dyestuff inside nanofibers, generating mordant/anthocyanin (M/ACN) coordinated complex nanoparticles. When exposed to ammonia, the color change of anthocyanin-encapsulated polycaprolactone-co-polylactic acid nanofibrous membrane from purple to transparent was examined by absorbance spectra and CIE Lab color parameters. With a quick colorimetric shift, the polycaprolactone-co-polylactic acid fabric exhibits a detection limit of 5-150 mg/L. The absorbance spectra showed a hypsochromic shift when exposed to ammonia, displaying an absorption shift from 559 nm to 391 nm with an isosbestic point of 448 nm. Scanning electron microscopy (SEM) images revealed that the polycaprolactone-co-polylactic acid nanofibers had a diameter of 75-125 nm, whereas transmission electron microscopy (TEM) images revealed that M/ACN nanoparticles exhibited diameters of 10-20 nm.
Collapse
Affiliation(s)
- Salhah D Al-Qahtani
- Department of Chemistry, College of Science, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia
| | - Ghadah M Al-Senani
- Department of Chemistry, College of Science, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia.
| |
Collapse
|
3
|
Khachornsakkul K, Leelasattarathkul T. Photothermal biosensing integrated with microfluidic paper-based analytical device for sensitive quantification of sarcosine. Talanta 2024; 271:125628. [PMID: 38219320 DOI: 10.1016/j.talanta.2024.125628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 11/13/2023] [Accepted: 01/04/2024] [Indexed: 01/16/2024]
Abstract
This article presents the development of a photothermal biosensing integrated with microfluidic paper-based analytical device (PT-μPAD) as a quantitative biosensor method for monitoring sarcosine in human control urine, plasma, and serum samples. The device utilizes gold nanoparticles (AuNPs) as both a peroxidase-like nanozyme and a photothermal substrate to enable sarcosine detection. In our PT-μPAD, hydrogen peroxide (H2O2) is generated through the oxidation of sarcosine by a sarcosine oxidase (SOx) enzyme. Subsequently, the H2O2 flows through the paper microchannels to the detection zone, where it etches the pre-deposited AuNPs, inducing a temperature change upon exposure by a 532 nm laser. The temperature variation is then measured using a portable and inexpensive infrared thermometer. Under optimized conditions, we obtained a linear range between 10.0 and 40.0 nmol L-1 (R2 = 0.9954) and a detection limit (LOD) of 32.0 pmol L-1. These values fall within the clinical range for sarcosine monitoring in prostate cancer diagnostics in humans. Moreover, our approach exhibits high selectivity without interfering effects. Recovery studies in various human control samples demonstrated a range of 99.05-102.11 % with the highest RSD of 2.25 %. The PT-μPAD was further validated for sarcosine determination in human control urine and compared with a commercial ELISA assay, revealing no significant difference between these two methods at a 95 % confidence level. Overall, our proposed sarcosine biosensor is well-suited for prostate cancer monitoring, given its affordability, sensitivity, and user-friendliness, even for unskilled individuals. Moreover, this strategy has promising prospects for broader applications, potentially detecting various biomarkers as a point-of-care (POC) diagnostic tool.
Collapse
Affiliation(s)
- Kawin Khachornsakkul
- Division of Chemistry, Department of Science, Faculty of Science and Technology, Rajamangala University of Technology Krungthep, Bangkok, 10120, Thailand; Department of Electrical and Computer Engineering, Tufts University, Medford, MA, 02155, USA
| | - Tapparath Leelasattarathkul
- Division of Chemistry, Department of Science, Faculty of Science and Technology, Rajamangala University of Technology Krungthep, Bangkok, 10120, Thailand.
| |
Collapse
|
4
|
Khachornsakkul K, Del-Rio-Ruiz R, Creasey H, Widmer G, Sonkusale SR. Gold Nanomaterial-Based Microfluidic Paper Analytical Device for Simultaneous Quantification of Gram-Negative Bacteria and Nitrite Ions in Water Samples. ACS Sens 2023; 8:4364-4373. [PMID: 37997658 DOI: 10.1021/acssensors.3c01769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2023]
Abstract
This study presents a rapid microfluidic paper-based analytical device (μPAD) capable of simultaneously monitoring Gram-negative bacteria and nitrite ions (NO2-) for water quality monitoring. We utilize gold nanoparticles (AuNPs) functionalized with polymyxin molecules (AuNPs@polymyxin) to cause color change due to aggregation for the detection of Gram-negative bacteria, and antiaggregation in the presence of o-phenylenediamine (OPD) for NO2- detection. In this study, Escherichia coli (E. coli) serves as the model of a Gram-negative bacterium. Using the developed μPADs, the color changes resulting from aggregation and antiaggregation reactions are measured using a smartphone application. The linear detection ranges from 5.0 × 102 to 5.0 × 105 CFU/mL (R2 = 0.9961) for E. coli and 0.20 to 2.0 μmol/L (R2 = 0.995) for NO2-. The detection limits were determined as 2.0 × 102 CFU/mL for E. coli and 0.18 μmol/L for NO2-. Notably, the newly developed assay exhibited high selectivity with no interference from Gram-positive bacteria. Additionally, we obtained acceptable recovery for monitoring E. coli and NO2- in drinking water samples with no significant difference between our method and a commercial assay by t test validation. The sensor was also employed for assessing the quality of the pond and environmental water source. Notably, this approach can also be applied to human urine samples with satisfactory accuracy. Furthermore, the assay's stability is extended due to its reliance on AuNPs rather than reagents like antibodies and enzymes, reducing costs and ensuring long-term viability. Our cost-effective μPADs therefore provide a real-time analysis of both contaminants, making them suitable for assessing water quality in resource-limited settings.
Collapse
Affiliation(s)
- Kawin Khachornsakkul
- Department of Electrical and Computer Engineering, Tufts University, Medford, Massachusetts 02155, United States
- Nano Lab, Tufts University, Medford, Massachusetts 02155, United States
| | - Ruben Del-Rio-Ruiz
- Department of Electrical and Computer Engineering, Tufts University, Medford, Massachusetts 02155, United States
- Nano Lab, Tufts University, Medford, Massachusetts 02155, United States
| | - Hannah Creasey
- Department of Infectious Diseases and Global Health, Cummings School of Veterinary Medicine, Tufts University, North Grafton, Massachusetts 01536, United States
| | - Giovanni Widmer
- Department of Infectious Diseases and Global Health, Cummings School of Veterinary Medicine, Tufts University, North Grafton, Massachusetts 01536, United States
| | - Sameer R Sonkusale
- Department of Electrical and Computer Engineering, Tufts University, Medford, Massachusetts 02155, United States
- Nano Lab, Tufts University, Medford, Massachusetts 02155, United States
| |
Collapse
|
5
|
Khachornsakkul K, Dungchai W, Pamme N. Distance-Based All-In-One Immunodevice for Point-of-Care Monitoring of Cytokine Interleukin-6. ACS Sens 2022; 7:2410-2419. [PMID: 35972061 DOI: 10.1021/acssensors.2c01122] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
We report the development of a distance-based paper analytical device combined with a hydrophilic bridge valve (B-dPAD) as a quantitative immunoassay method to monitor human interleukin-6 (IL-6) in human samples. Our device design features (i) a circular sample inlet zone, (ii) a circular capture zone with immobilized anti-IL-6 (anti-Ab1), and (iii) a detection zone channel coated with methylene blue (MB). Two hydrophilic valves are positioned between these three zones. IL-6 levels were determined quantitatively by measuring the extent of degradation of MB to a colorless product along the length of the detection zone channel. Following method optimization, we obtained a linear range from 0.05 to 25.0 pg/mL (R2 = 0.9995) and a detection limit (LOD) of 0.05 pg/mL by the naked-eye readout. This is directly within the clinically relevant range. The system does not require any external instrumentation, and the bridge valves can be easily connected and disconnected by a minimally trained operator. The total analysis time is 35 min, significantly reduced from a typical ELISA assay, which takes around 1 h since the B-dPAD workflow circumvents washing steps. The device was tested for IL-6 quantification in human saliva and urine samples of volunteers, with no significant difference found between our method and the standard clinical laboratory method at 95% confidence levels. Recoveries ranged from 98 to 105% with the highest standard deviation at 3.9%. Our B-dPAD immunodevice is therefore a promising approach for rapid IL-6 monitoring in the context of point-of-care diagnostics and analysis in resource-limited settings.
Collapse
Affiliation(s)
- Kawin Khachornsakkul
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology, Prachautid Road, Thungkru, Thonburi, Bangkok 10140, Thailand.,Department/ of Chemistry and Biochemistry, University of Hull, Cottingham Road, Hull HU6 7RX, United Kingdom
| | - Wijitar Dungchai
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology, Prachautid Road, Thungkru, Thonburi, Bangkok 10140, Thailand
| | - Nicole Pamme
- Department/ of Chemistry and Biochemistry, University of Hull, Cottingham Road, Hull HU6 7RX, United Kingdom.,Department of Materials and Environmental Chemistry, Stockholm University, Svante Arrhenius väg 16C, Stockholm 106 91, Sweden
| |
Collapse
|
6
|
A Flexible and Attachable Colorimetric Film Sensor for the Detection of Gaseous Ammonia. BIOSENSORS 2022; 12:bios12080664. [PMID: 36005060 PMCID: PMC9405545 DOI: 10.3390/bios12080664] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 08/11/2022] [Accepted: 08/12/2022] [Indexed: 11/16/2022]
Abstract
A cost-effective, simple, flexible, and disposable colorimetric film sensor was constructed for the rapid detection of gaseous ammonia. The sensor was designed to consist of three layers, namely top, middle, and bottom layers of a polymeric elastomer. The bromocresol (BCG) indicator embedded in the middle layer of the film facilitated a change in color of the sensor from yellow-orange to blue upon exposure to gaseous ammonia. The color change was visually observed by the naked eye. The sensitivity of the sensor was verified by a successful detection of gaseous ammonia at concentrations from 4 to 235 ppm within 3 min, and the corresponding visual detection of ammonia gas was at a concentration as low as 11 ppm. The sensor also achieved a selective detection of gaseous ammonia over a variety of alkaline chemicals. The color of the sensor exposed to ammonia reverted from blue to the original yellow-orange upon subsequent exposure to the fume of acetic acid or aeration for 48 h, and it showed reliable performance for the detection of gaseous ammonia even after five repeated uses. The applicability of the sensor was validated by attaching it onto a safety helmet for a simulation of an industrial ammonia gas leak. The results indicated that our colorimetric film sensor is affordable, disposable, and reproducible, and can serve as an effective alternative for simple and rapid recognition of gaseous ammonia in environmental and air quality monitoring as well as in industrial applications.
Collapse
|
7
|
Haq SU, Aghajamali M, Hassanzadeh H. Cost-effective and sensitive anthocyanin-based paper sensors for rapid ammonia detection in aqueous solutions. RSC Adv 2021; 11:24387-24397. [PMID: 35479052 PMCID: PMC9036918 DOI: 10.1039/d1ra04069c] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Accepted: 07/04/2021] [Indexed: 11/21/2022] Open
Abstract
In this work, we developed a cost-effective and environmentally friendly anthocyanin-based paper sensor with high sensitivity and optical visibility for the rapid detection of ammonia in aqueous solutions. The detection principle is based on a color change upon ammonia exposure to an anthocyanin-containing paper, which can be recorded simply via a smartphone. The paper sensors were fabricated by extracting anthocyanin from different sources (i.e., red cabbage, blueberry, and blackberry) and immersing pre-cut paper in anthocyanin extracts. Anthocyanin was extracted from different sources into water and aqueous ethanolic solution (80%) using solid-liquid extraction (SLE) and sonication assisted extraction (SAE) methods. The sensor sensitivity and optical visibility were improved by selecting a suitable combination of anthocyanin source, extraction technique, and solvent and controlling the ammonia release from the samples via alkalinization using a suitable base. Sensors fabricated with anthocyanin extracted from red cabbage (Red-C) into water using the SLE method and samples alkalinized with NaOH showed higher sensor sensitivity and better optical visibility. The Red-C anthocyanin sensors also exhibited a visible color change from dark to light blue for ammonia samples with concentrations as low as 2 mg NH3-N/L. Moreover, the spike recovery results of the sensors (101.9-109.4%) were in good agreement with those of the standard spectrophotometry method (105.4-112.2%), which suggest that these biosensors are a promising analytical tool as a replacement for time-consuming and environmentally unfriendly standard spectrophotometry methods for the on-site screening of ammonia.
Collapse
Affiliation(s)
- Shamshad Ul Haq
- Department of Chemical and Petroleum Engineering, University of Calgary Alberta Canada
| | - Maryam Aghajamali
- Department of Chemical and Petroleum Engineering, University of Calgary Alberta Canada
| | - Hassan Hassanzadeh
- Department of Chemical and Petroleum Engineering, University of Calgary Alberta Canada
| |
Collapse
|