1
|
Esene JE, Burningham AJ, Tahir A, Nordin GP, Woolley AT. 3D printed microfluidic devices for integrated solid-phase extraction and microchip electrophoresis of preterm birth biomarkers. Anal Chim Acta 2024; 1296:342338. [PMID: 38401930 PMCID: PMC10895869 DOI: 10.1016/j.aca.2024.342338] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 01/31/2024] [Accepted: 02/04/2024] [Indexed: 02/26/2024]
Abstract
BACKGROUND Preterm birth (PTB) is a leading cause of neonatal mortality, such that the need for a rapid and accurate assessment for PTB risk is critical. Here, we developed a 3D printed microfluidic system that integrated solid-phase extraction (SPE) and microchip electrophoresis (μCE) of PTB biomarkers, enabling the combination of biomarker enrichment and labeling with μCE separation and fluorescence detection. RESULTS Reversed-phase SPE monoliths were photopolymerized in 3D printed devices. Microvalves in the device directed sample between the SPE monolith and the injection cross-channel in the serpentine μCE channel. Successful on-chip preconcentration, labeling and μCE separation of four PTB-related polypeptides were demonstrated in these integrated microfluidic devices. We further show the ability of these devices to handle complex sample matrices through the successful analysis of labeled PTB biomarkers spiked into maternal blood serum. The detection limit was 7 nM for the PTB biomarker, corticotropin releasing factor, in 3D printed SPE-μCE integrated devices. SIGNIFICANCE This work represents the first successful demonstration of integration of SPE and μCE separation of disease-linked biomarkers in 3D printed microfluidic devices. These studies open up promising possibilities for rapid bioanalysis of medically relevant analytes.
Collapse
Affiliation(s)
- Joule E Esene
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602, USA
| | - Addalyn J Burningham
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602, USA
| | - Anum Tahir
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602, USA
| | - Gregory P Nordin
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT, 84602, USA
| | - Adam T Woolley
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602, USA.
| |
Collapse
|
2
|
Gondane P, Kumbhakarn S, Maity P, Kapat K. Recent Advances and Challenges in the Early Diagnosis and Treatment of Preterm Labor. Bioengineering (Basel) 2024; 11:161. [PMID: 38391647 PMCID: PMC10886370 DOI: 10.3390/bioengineering11020161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Revised: 01/30/2024] [Accepted: 02/04/2024] [Indexed: 02/24/2024] Open
Abstract
Preterm birth (PTB) is the primary cause of neonatal mortality and long-term disabilities. The unknown mechanism behind PTB makes diagnosis difficult, yet early detection is necessary for controlling and averting related consequences. The primary focus of this work is to provide an overview of the known risk factors associated with preterm labor and the conventional and advanced procedures for early detection of PTB, including multi-omics and artificial intelligence/machine learning (AI/ML)- based approaches. It also discusses the principles of detecting various proteomic biomarkers based on lateral flow immunoassay and microfluidic chips, along with the commercially available point-of-care testing (POCT) devices and associated challenges. After briefing the therapeutic and preventive measures of PTB, this review summarizes with an outlook.
Collapse
Affiliation(s)
- Prashil Gondane
- Department of Medical Devices, National Institute of Pharmaceutical Education and Research Kolkata, 168, Maniktala Main Road, Kankurgachi, Kolkata 700054, India
| | - Sakshi Kumbhakarn
- Department of Medical Devices, National Institute of Pharmaceutical Education and Research Kolkata, 168, Maniktala Main Road, Kankurgachi, Kolkata 700054, India
| | - Pritiprasanna Maity
- Department of Regenerative Medicine and Cell Biology, Medical University of South Carolina, Charleston, SC 29425, USA
| | - Kausik Kapat
- Department of Medical Devices, National Institute of Pharmaceutical Education and Research Kolkata, 168, Maniktala Main Road, Kankurgachi, Kolkata 700054, India
| |
Collapse
|
3
|
Nielsen JB, Holladay JD, Burningham AJ, Rapier-Sharman N, Ramsey JS, Skaggs TB, Nordin GP, Pickett BE, Woolley AT. Monolithic affinity columns in 3D printed microfluidics for chikungunya RNA detection. Anal Bioanal Chem 2023; 415:7057-7065. [PMID: 37801120 PMCID: PMC10840819 DOI: 10.1007/s00216-023-04971-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 09/15/2023] [Accepted: 09/20/2023] [Indexed: 10/07/2023]
Abstract
Mosquito-borne pathogens plague much of the world, yet rapid and simple diagnosis is not available for many affected patients. Using a custom stereolithography 3D printer, we created microfluidic devices with affinity monoliths that could retain, noncovalently attach a fluorescent tag, and detect oligonucleotide and viral RNA. We optimized the fluorescent binding and sample load times using an oligonucleotide sequence from chikungunya virus (CHIKV). We also tested the specificity of CHIKV capture relative to genetically similar Sindbis virus. Moreover, viral RNA from both viruses was flowed through capture columns to study the efficiency and specificity of the column for viral CHIKV. We detected ~107 loaded viral genome copies, which was similar to levels in clinical samples during acute infection. These results show considerable promise for development of this platform into a rapid mosquito-borne viral pathogen detection system.
Collapse
Affiliation(s)
- Jacob B Nielsen
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA
| | - James D Holladay
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA
| | - Addalyn J Burningham
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA
| | - Naomi Rapier-Sharman
- Department of Microbiology and Molecular Biology, Brigham Young University, Provo, UT, USA
| | - Joshua S Ramsey
- Department of Microbiology and Molecular Biology, Brigham Young University, Provo, UT, USA
| | - Timothy B Skaggs
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA
| | - Gregory P Nordin
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT, USA
| | - Brett E Pickett
- Department of Microbiology and Molecular Biology, Brigham Young University, Provo, UT, USA
| | - Adam T Woolley
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, USA.
| |
Collapse
|
4
|
Zhu N, Wu Z, He M, Chen B, Hu B. 3D printed stir bar sorptive extraction coupled with high performance liquid chromatography for trace estrogens analysis in environmental water samples. Anal Chim Acta 2023; 1281:341904. [PMID: 38783742 DOI: 10.1016/j.aca.2023.341904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 10/08/2023] [Accepted: 10/10/2023] [Indexed: 05/25/2024]
Abstract
BACKGROUND Any imaginary shape with good preparation reproducibility can be made by 3D printing technology, and it has been applied in various fields. Comparatively, its applications in sample pre-treatment are relatively less, most of which involves making extraction sorbents and producing non-functionalized devices for support assistance. 3D printing has not been applied to fabricate stir bars in stir bar sorptive extraction, mainly due to the lacking of suitable printing feedstocks. This work aimed to fabricate stir bars by 3D printing, reducing the manufacturing cost and steps and improving preparation reproducibility. (90) RESULTS: By using fused deposition modeling technique and porous filament printing feedstock, stir bars were fabricated without any modifications. Adsorption performance of 3D printed stir bars were investigated for substances with different structures and polarities. Five estrogens with adsorption efficiencies of over 80 % were selected as the representatives. The 3D printed stir bars exhibited good preparation reproducibility (2.9-4.4 %) and higher extraction recoveries (73-81 %) for five estrogens than commercial polydimethylsiloxane coated stir bars (13-69 %) in a shorter time (90 vs 120 min). They showed long lifespan (160 times) with good mechanical properties and merited reduced manufacturing cost (0.064 $ per bar) and manual operation. A method of stir bar sorptive extraction coupled with high performance liquid chromatography was proposed for trace analysis of estrogens in environmental water. Under the optimized conditions, the linear ranges for estrogens were 0.5-200 μg/L with LODs of 0.13-0.17 μg/L. (136) SIGNIFICANCE: The feasibility of fused deposition modeling in stir bar fabrication was demonstrated, along with the potential of porous filament printing feedstock as the sorbent for substances with medium polarity. 3D printed stir bars were featured with excellent preparation reproducibility, long lifespan, and good mechanical properties. The stir bar fabrication method can be used for mass production with minimal differences in products performance. (62).
Collapse
Affiliation(s)
- Ning Zhu
- Department of Chemistry, Wuhan University, Wuhan, 430072, China
| | - Zhekuan Wu
- Tobacco Research Institute of Hubei Province, Hubei Tobacco Company, Wuhan, 430040, China
| | - Man He
- Department of Chemistry, Wuhan University, Wuhan, 430072, China
| | - Beibei Chen
- Department of Chemistry, Wuhan University, Wuhan, 430072, China
| | - Bin Hu
- Department of Chemistry, Wuhan University, Wuhan, 430072, China.
| |
Collapse
|
5
|
Cardoso BD, Castanheira EMS, Lanceros‐Méndez S, Cardoso VF. Recent Advances on Cell Culture Platforms for In Vitro Drug Screening and Cell Therapies: From Conventional to Microfluidic Strategies. Adv Healthc Mater 2023; 12:e2202936. [PMID: 36898671 PMCID: PMC11468737 DOI: 10.1002/adhm.202202936] [Citation(s) in RCA: 33] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 02/27/2023] [Indexed: 03/12/2023]
Abstract
The clinical translations of drugs and nanomedicines depend on coherent pharmaceutical research based on biologically accurate screening approaches. Since establishing the 2D in vitro cell culture method, the scientific community has improved cell-based drug screening assays and models. Those advances result in more informative biochemical assays and the development of 3D multicellular models to describe the biological complexity better and enhance the simulation of the in vivo microenvironment. Despite the overall dominance of conventional 2D and 3D cell macroscopic culture methods, they present physicochemical and operational challenges that impair the scale-up of drug screening by not allowing a high parallelization, multidrug combination, and high-throughput screening. Their combination and complementarity with microfluidic platforms enable the development of microfluidics-based cell culture platforms with unequivocal advantages in drug screening and cell therapies. Thus, this review presents an updated and consolidated view of cell culture miniaturization's physical, chemical, and operational considerations in the pharmaceutical research scenario. It clarifies advances in the field using gradient-based microfluidics, droplet-based microfluidics, printed-based microfluidics, digital-based microfluidics, SlipChip, and paper-based microfluidics. Finally, it presents a comparative analysis of the performance of cell-based methods in life research and development to achieve increased precision in the drug screening process.
Collapse
Affiliation(s)
- Beatriz D. Cardoso
- Physics Centre of Minho and Porto Universities (CF‐UM‐UP), Campus de GualtarUniversity of MinhoBraga4710‐057Portugal
- LaPMET‐Laboratory of Physics for Materials and Emergent TechnologiesUniversity of Minho4710‐057BragaPortugal
- Center for MicroElectromechanical Systems (CMEMS‐UMinho)Campus de AzurémUniversity of Minho4800‐058GuimarãesPortugal
- LABBELS‐Associate Laboratory in Biotechnology and Bioengineering and Microelectromechanical SystemsUniversity of MinhoBraga/GuimarãesPortugal
| | - Elisabete M. S. Castanheira
- Physics Centre of Minho and Porto Universities (CF‐UM‐UP), Campus de GualtarUniversity of MinhoBraga4710‐057Portugal
- LaPMET‐Laboratory of Physics for Materials and Emergent TechnologiesUniversity of Minho4710‐057BragaPortugal
| | - Senentxu Lanceros‐Méndez
- Physics Centre of Minho and Porto Universities (CF‐UM‐UP), Campus de GualtarUniversity of MinhoBraga4710‐057Portugal
- LaPMET‐Laboratory of Physics for Materials and Emergent TechnologiesUniversity of Minho4710‐057BragaPortugal
- BCMaterialsBasque Center for MaterialsApplications and NanostructuresUPV/EHU Science ParkLeioa48940Spain
- IKERBASQUEBasque Foundation for ScienceBilbao48009Spain
| | - Vanessa F. Cardoso
- Center for MicroElectromechanical Systems (CMEMS‐UMinho)Campus de AzurémUniversity of Minho4800‐058GuimarãesPortugal
- LABBELS‐Associate Laboratory in Biotechnology and Bioengineering and Microelectromechanical SystemsUniversity of MinhoBraga/GuimarãesPortugal
| |
Collapse
|
6
|
Esene JE, Nasman PR, Akuoko Y, Tahir A, Woolley AT. Past, current, and future roles of 3D printing in the development of capillary electrophoresis systems. Trends Analyt Chem 2023; 162:117032. [PMID: 37008739 PMCID: PMC10062378 DOI: 10.1016/j.trac.2023.117032] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/30/2023]
Abstract
3D printing, an additive manufacturing technology, has made significant inroads into improving systems for bioanalysis in recent years. This approach is particularly powerful due to the ease and flexibility in rapidly creating novel and complex designs for analytical applications. As such, 3D printing offers an emerging technology for creating systems for electrophoretic analysis. Here, we review 3D printing work on improving and miniaturizing capillary electrophoresis (CE), emphasizing publications from 2019‒2022. We describe enabling uses of 3D printing in interfacing upstream sample preparation or downstream detection with CE. Recent developments in miniaturized CE enabled by 3D printing are also elaborated, including key areas where 3D printing could further improve over the current state-of-the-art. Lastly, we highlight promising future trends for using 3D printing in miniaturizing CE and the significant potential for innovative advancements. 3D printing is poised to play a key role in moving forward miniaturized CE in the coming years.
Collapse
Affiliation(s)
- Joule E. Esene
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA
| | - Parker R. Nasman
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA
| | - Yesman Akuoko
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA
| | - Anum Tahir
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA
| | - Adam T. Woolley
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA
| |
Collapse
|
7
|
Gil J, Krimm I, Dugas V, Demesmay C. Preparation of miniaturized hydrophilic affinity monoliths: Towards a reduction of non-specific interactions and an increased target protein density. J Chromatogr A 2023; 1687:463670. [PMID: 36463648 DOI: 10.1016/j.chroma.2022.463670] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 11/23/2022] [Accepted: 11/23/2022] [Indexed: 11/26/2022]
Abstract
In affinity chromatography, non-specific interactions between the ligands and the affinity column may affect the results, leading to misinterpretations during the investigation of protein-ligand interactions (detection of false positives in ligand screening, lack of specificity in purification). Such non-specific interactions may arise both from the underlying support or from the target protein itself. If the second ones are protein-dependent (and cannot be studied in a general framework), the first ones occur in the same way regardless of the immobilized target. We propose a methodology to identify the origin of such non-specific interactions with the underlying material of the affinity column. This methodology relies on the systematic investigation of the retention behavior of a set of 41 low-molecular weight compounds covering a wide chemical space (net charge, log D, functionality). We first demonstrate that the main source of non-specific interactions on the most commonly used GMA-co-EDMA monolith comes from hydrophobic effects. To reduce such non-specific interactions, we developed a new hydrophilic glycidyl methacrylate-based monolith by replacing the EDMA crosslinker by the more hydrophilic NN' Methylenebisacrylamide (MBA). Optimization of the synthesis parameters (monomer content, initiation type, temperature) has focused on the reduction of non-specific interaction with the monolithic support while maximizing the amount of protein that can be grafted onto the monolith at the issue of its synthesis. The retention data of the 41 test solutes on the new poly(GMA-co-MBA) monolith shows a drastic reduction of non-specific interactions except for cationic compounds. The particular behavior of cationic compounds is due to their electrostatic interactions with carboxylic groups resulting from the partial acidic hydrolysis of amide groups of MBA during the epoxide ring opening step. So, the ring opening step in acidic media was replaced by a hot water treatment to avoid side reaction on MBA. The new monolith poly(GMA-co-MBA) not only has improved hydrophilic surface properties but also a higher protein density (16 ± 0.8 pmol cm-1 instead of 8 ± 0.3 pmol cm-1). To highlight the benefits of this new hydrophilic monolith for affinity chromatographic studies, frontal affinity chromatography experiments were conducted on these monoliths grafted with con A.
Collapse
Affiliation(s)
- Julie Gil
- Institut des Sciences Analytiques, Université de Lyon, CNRS, Université Claude Bernard Lyon 1, UMR 5280, 5 rue de la Doua, Villeurbanne F-69100, France
| | - Isabelle Krimm
- Centre Léon Bérard, INSERM 1052, CNRS 5286, Centre de Recherche en Cancérologie de Lyon, Small Molecules for Biological Targets Team, Université de Lyon, Université Claude Bernard Lyon 1, Lyon 69373, France
| | - Vincent Dugas
- Institut des Sciences Analytiques, Université de Lyon, CNRS, Université Claude Bernard Lyon 1, UMR 5280, 5 rue de la Doua, Villeurbanne F-69100, France.
| | - Claire Demesmay
- Institut des Sciences Analytiques, Université de Lyon, CNRS, Université Claude Bernard Lyon 1, UMR 5280, 5 rue de la Doua, Villeurbanne F-69100, France
| |
Collapse
|
8
|
Prabowo BA, Sousa C, Cardoso S, Freitas P, Fernandes E. Labeling on a Chip of Cellular Fibronectin and Matrix Metallopeptidase-9 in Human Serum. MICROMACHINES 2022; 13:1722. [PMID: 36296077 PMCID: PMC9611906 DOI: 10.3390/mi13101722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Revised: 10/07/2022] [Accepted: 10/10/2022] [Indexed: 06/16/2023]
Abstract
We present a microfluidic chip for protein labeling in the human serum-based matrix. Serum is a complex sample matrix that contains a variety of proteins, and a matrix is used in many clinical tests. In this study, the device performance was tested using commercial serum samples from healthy donors spiked with the following target proteins: cellular fibronectin (c-Fn) and matrix metallopeptidase 9 (MMP9). The microfluidic molds were fabricated using micro milling on acrylic and using stereolithography (SLA) three-dimensional (3D) printing for an alternative method and comparison. A simple quality control was performed for both fabrication mold methods to inspect the channel height of the chip that plays a critical role in the labeling process. The fabricated microfluidic chip shows a good reproducibility and repeatability of the performance for the optimized channel height of 150 µm. The spiked proteins of c-Fn and MMP9 in the human serum-based matrix, were successfully labeled by the functionalized magnetic nanoparticles (MNPs). The biomarker labeling occurring in the serum was compared using a simple matrix sample: phosphate buffer. The measured signals obtained by using a magnetoresistive (MR) biochip platform showed that the labeling using the proposed microfluidic chip is in good agreement for both matrixes, i.e., the analytical performance (sensitivity) obtained with the serum, near the relevant cutoff values, is within the uncertainty of the measurements obtained with a simple and more controlled matrix: phosphate buffer. This finding is promising for stroke patient stratification where these biomarkers are found at high concentrations in the serum.
Collapse
Affiliation(s)
| | - Carole Sousa
- International Iberian Nanotechnology Laboratory (INL), 4715-330 Braga, Portugal
| | - Susana Cardoso
- INESC-MN– Institute for Systems and Computer Engineering-Microsystems and Nanotechnologies,1000-029 Lisbon, Portugal
| | - Paulo Freitas
- International Iberian Nanotechnology Laboratory (INL), 4715-330 Braga, Portugal
| | - Elisabete Fernandes
- International Iberian Nanotechnology Laboratory (INL), 4715-330 Braga, Portugal
| |
Collapse
|
9
|
Garcia-Rey S, Nielsen JB, Nordin GP, Woolley AT, Basabe-Desmonts L, Benito-Lopez F. High-Resolution 3D Printing Fabrication of a Microfluidic Platform for Blood Plasma Separation. Polymers (Basel) 2022; 14:polym14132537. [PMID: 35808588 PMCID: PMC9269563 DOI: 10.3390/polym14132537] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 06/14/2022] [Accepted: 06/16/2022] [Indexed: 12/04/2022] Open
Abstract
Additive manufacturing technology is an emerging method for rapid prototyping, which enables the creation of complex geometries by one-step fabrication processes through a layer-by-layer approach. The simplified fabrication achieved with this methodology opens the way towards a more efficient industrial production, with applications in a great number of fields such as biomedical devices. In biomedicine, blood is the gold-standard biofluid for clinical analysis. However, blood cells generate analytical interferences in many test procedures; hence, it is important to separate plasma from blood cells before analytical testing of blood samples. In this research, a custom-made resin formulation combined with a high-resolution 3D printing methodology were used to achieve a methodology for the fast prototype optimization of an operative plasma separation modular device. Through an iterative process, 17 different prototypes were designed and fabricated with printing times ranging from 5 to 12 min. The final device was evaluated through colorimetric analysis, validating this fabrication approach for the qualitative assessment of plasma separation from whole blood. The 3D printing method used here demonstrates the great contribution that this microfluidic technology will bring to the plasma separation biomedical devices market.
Collapse
Affiliation(s)
- Sandra Garcia-Rey
- Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC) Group, Analytical Chemistry Department, University of the Basque Country UPV/EHU, 48940 Leioa, Spain;
- Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, 01006 Vitoria-Gasteiz, Spain
| | - Jacob B. Nielsen
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA;
| | - Gregory P. Nordin
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT 84602, USA;
| | - Adam T. Woolley
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA;
- Correspondence: (A.T.W.); (L.B.-D.); (F.B.-L.)
| | - Lourdes Basabe-Desmonts
- Microfluidics Cluster UPV/EHU, BIOMICs Microfluidics Group, Lascaray Research Center, University of the Basque Country UPV/EHU, 01006 Vitoria-Gasteiz, Spain
- Bioaraba Health Research Institute, Microfluidics Cluster UPV/EHU, 01009 Vitoria-Gasteiz, Spain
- BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Spain
- Basque Foundation of Science, IKERBASQUE, Calle María Díaz de Haro 3, 48013 Bilbao, Spain
- Correspondence: (A.T.W.); (L.B.-D.); (F.B.-L.)
| | - Fernando Benito-Lopez
- Microfluidics Cluster UPV/EHU, Analytical Microsystems & Materials for Lab-on-a-Chip (AMMa-LOAC) Group, Analytical Chemistry Department, University of the Basque Country UPV/EHU, 48940 Leioa, Spain;
- Bioaraba Health Research Institute, Microfluidics Cluster UPV/EHU, 01009 Vitoria-Gasteiz, Spain
- BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, 48940 Leioa, Spain
- Correspondence: (A.T.W.); (L.B.-D.); (F.B.-L.)
| |
Collapse
|
10
|
Esene JE, Boaks M, Bickham AV, Nordin GP, Woolley AT. 3D printed microfluidic device for automated, pressure-driven, valve-injected microchip electrophoresis of preterm birth biomarkers. Mikrochim Acta 2022; 189:204. [PMID: 35484354 PMCID: PMC10079432 DOI: 10.1007/s00604-022-05303-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Accepted: 03/31/2022] [Indexed: 11/30/2022]
Abstract
A 3D printed, automated, pressure-driven injection microfluidic system for microchip electrophoresis (µCE) of preterm birth (PTB)-related peptides and proteins has been developed. Functional microvalves were formed, either with a membrane thickness of 5 µm and a layer exposure time of 450 ms or with a membrane thickness of 10 µm and layer exposure times of 300-350 ms. These valves allowed for control of fluid flow in device microchannels during sample injection for µCE separation. Device design and µCE conditions using fluorescently labeled amino acids were optimized. A sample injection time of 0.5 s and a separation voltage of 450 V (460 V/cm) yielded the best separation efficiency and resolution. We demonstrated the first µCE separation with pressure-driven injection in a 3D printed microfluidic device using fluorescently labeled PTB biomarkers and 532 nm laser excitation. Detection limits for two PTB biomarkers, peptide 1 and peptide 2, for an injection time of 1.5 s were 400 pM and 15 nM, respectively, and the linear detection range for peptide 2 was 50-400 nM. This 3D printed microfluidic system holds promise for future integration of on-chip sample preparation processes with µCE, offering promising possibilities for PTB risk assessment.
Collapse
Affiliation(s)
- Joule E Esene
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602, USA
| | - Mawla Boaks
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT, 84602, USA
| | - Anna V Bickham
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602, USA
| | - Gregory P Nordin
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT, 84602, USA
| | - Adam T Woolley
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602, USA.
| |
Collapse
|