1
|
Zhang Z, Zhu L, Zhang Y, Zong Y, Li Y, Zheng Y, Meng M, Zhang Z. Development and application of a CNT-Ag-Cu-Al/PS-based paper electrode for detecting diverse analytes in complex matrices. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:3949-3956. [PMID: 38842287 DOI: 10.1039/d4ay00550c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2024]
Abstract
Electrochemical sensors play a crucial role in the detection of different analytes in complex matrices, and their performance is highly dependent on the electrode capacity. However, most of the available electrodes can only be used for single-component detection, so it is urgent to develop electrodes with high sensitivity and selectivity for different components. Herein, we report an amphiprotic amino-bonded carbon nanotube-Ag/Cu/Al nanoparticle/polystyrene-coated paper electrode (CNT-Ag-Cu-Al/PS electrode), which can be used for the measurement of glucose (Glc), oxytetracycline (OTC), and hydroquinone (HQ), respectively. The results showed that the analytical sensitivity and selectivity of the CNT-Ag-Cu-Al/PS electrode were comparable to those of single metal-coated paper substrate. The developed electrode also exhibited excellent linear responses for Glc, OTC, and HQ in the ranges of 1.0-1000.0 μM, 1.0 × 10-2 to 10.0 μM, and 5.0 × 10-3 to 50.0 μM, and the limits of detection (LODs) were 0.2055 μM (Glc), 0.0074 μM (OTC), and 0.0048 μM (HQ). Owing to the characteristics of good selectivity, anti-interference, stability, and reproducibility, the CNT-Ag-Cu-Al/PS paper electrode has been successfully applied to the detection of these analytes in complex human body fluids, food, and environmental waters. The paper electrode is promising for the detection of target compounds in complex matrices.
Collapse
Affiliation(s)
- Zhiming Zhang
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China.
| | - Lixuan Zhu
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China.
| | - Yan Zhang
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China.
| | - Yanan Zong
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China.
- Xianyang Product Quality Supervision and Inspection Institute, Xianyang 712000, China
| | - Yun Li
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China.
| | - Yajun Zheng
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China.
| | - Mei Meng
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China.
| | - Zhiping Zhang
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China.
| |
Collapse
|
2
|
Bagheri R, Alikhani S, Miri-Moghaddam E. Fabrication of conductive Ag/AgCl/Ag nanorods ink on Laser-induced graphene electrodes on flexible substrates for non-enzymatic glucose detection. Sci Rep 2023; 13:20898. [PMID: 38017145 PMCID: PMC10684547 DOI: 10.1038/s41598-023-48322-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2023] [Accepted: 11/24/2023] [Indexed: 11/30/2023] Open
Abstract
An unusual strategy was designed to fabricate conductive patterns for flexible surfaces, which were utilized for non-enzymatic amperometric glucose sensors. The Ag/AgCl/Ag quasi-reference ink formulation utilized two reducing agents, NaBH[Formula: see text] and ethylene glycol. The parameters of the ink, such as sintering time and temperature, NaBH[Formula: see text] concentration, and layer number of coatings on flexible laser-induced graphene (LIG) electrodes were investigated. The conductive Ag/AgCl/Ag ink was characterized using electrochemical and surface analysis techniques. The electrocatalytic activity of Ag/AgCl/Ag NRs can be attributed to their high surface area, which offer numerous active sites for catalytic reactions. The selectivity and sensitivity of the electrodes for glucose detection were investigated. The XRD analysis showed (200) oriented AgCl on covered Ag NRs, and with the addition of NaBH[Formula: see text], the intensity of the peaks of the Ag NRs increased. The wide linear range of non-enzymatic sensors was attained from 0.003 to 0.18 mM and 0.37 to 5.0 mM, with a low limit of detection of 10 [Formula: see text]M and 20 [Formula: see text]M, respectively.The linear range of enzymatic sensor in real sample was determined from 0.040 to 0.097 mM with a detection limit of 50 [Formula: see text]M. Furthermore, results of the interference studies demonstrated excellent selectivity of the Ag/AgCl/Ag NRs/LIG electrode. The Ag/AgCl/Ag NRs on the flexible LIG electrode exhibited excellent sensitivity,long-time stablity,and reproducibility. The efficient electroactivity were deemed suitable for various electrochemical applications and biosensors.
Collapse
Affiliation(s)
- Rana Bagheri
- Department of Molecular Medicine, Faculty of Medicine, Cardiovascular Diseases Research Center, Birjand University of Medical Sciences, Birjand, 9717853577, Iran
- Nanofanavaran partopooyesh Company, Science and Technology Park of South Khorasan, Birjand, 9718643683, Iran
| | - Saeid Alikhani
- Nanofanavaran partopooyesh Company, Science and Technology Park of South Khorasan, Birjand, 9718643683, Iran
| | - Ebrahim Miri-Moghaddam
- Department of Molecular Medicine, Faculty of Medicine, Cardiovascular Diseases Research Center, Birjand University of Medical Sciences, Birjand, 9717853577, Iran.
| |
Collapse
|
3
|
Lee D, Jang J, Jang J. Sensitive and highly rapid electrochemical measurement of airborne coronaviruses through condensation-based direct impaction onto carbon nanotube-coated porous paper working electrodes. JOURNAL OF HAZARDOUS MATERIALS 2023; 458:131972. [PMID: 37399725 DOI: 10.1016/j.jhazmat.2023.131972] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Revised: 06/26/2023] [Accepted: 06/28/2023] [Indexed: 07/05/2023]
Abstract
Rapid detection of indoor airborne viruses is critical to prevent the spread of respiratory diseases. Herein, we present sensitive, highly rapid electrochemical measurement of airborne coronaviruses through condensation-based direct impaction onto antibody-immobilized, carbon nanotube-coated porous paper working electrodes (PWEs). Carboxylated carbon nanotubes are drop-cast on paper fibers to make three-dimensional (3D) porous PWEs. These PWEs have higher active surface area-to-volume ratios and electron transfer characteristics than conventional screen-printed electrodes. The limit of detection and detection time of the PWEs for liquid-borne coronaviruses OC43 are 65.7 plaque-forming units (PFU)/mL and 2 min, respectively. The PWEs showed sensitive and rapid detection of whole coronaviruses, which can be ascribed to the 3D porous electrode structure of the PWEs. Moreover, water molecules condense on airborne virus particles during air sampling, and these water-encapsulated virus particles (<4 µm) are impacted on the PWE for direct measurement without virus lysis and elution. The whole detection takes ∼10 min, including air sampling, at virus concentrations of 1.8 and 11.5 PFU/L of air, which can be due to the highly enriching and minimally damaging virus capture on a soft and porous PWE, demonstrating the potential for the rapid and low-cost airborne virus monitoring system.
Collapse
Affiliation(s)
- Daesoon Lee
- Sensors and Aerosols Laboratory, Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| | - Junbeom Jang
- Sensors and Aerosols Laboratory, Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| | - Jaesung Jang
- Sensors and Aerosols Laboratory, Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea; Department of Biomedical Engineering & Department of Urban and Environmental Engineering, UNIST, Ulsan 44919, Republic of Korea.
| |
Collapse
|
4
|
Zheng Y, Zuo Q, Xiang Z, Huang Y, Zhang Z. Improvement in the performance of focusing plasma desorption ionization by altering its counter electrode. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2023; 37 Suppl 1:e9458. [PMID: 36523174 DOI: 10.1002/rcm.9458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 12/13/2022] [Accepted: 12/14/2022] [Indexed: 06/17/2023]
Abstract
RATIONALE Plasma-based ionization sources play a vital role in rapidly analyzing diverse compounds without extensive sample pretreatment. In contrast to other sources, DC voltage-based ionizations are more advantageous due to their high analytical sensitivity and good tandem with commercially available mass spectrometers without extra power supplies. However, their performance is at the risk of high current DC voltage and helium flow rate, which poses significant challenges to practical operation and increased expense. METHODS In this work, we propose a novel focusing plasma desorption ionization (FPDI) in which a visible plasma beam is favorably generated between a conducting wire in a polymeric tube and a counter electrode composed of metal mesh and filter paper drilled with holes. A systematic investigation has been conducted on the influences of the geometry of drilled holes in filter paper, applied DC voltage, helium flow rate, and filter paper size. The optimized system is used to analyze various pesticides in fluid foodstuffs. RESULTS Compared to metal mesh and conducting paper as the counter electrode for FPDI-MS, combining metal mesh and filter paper drilled holes improved the analysis sensitivity by a factor of more than five. By applying the developed protocol for determining pesticides in complex matrixes such as orange juice and milk, a limit of detection as low as 1.3-3.0 ng mL-1 could be achieved. CONCLUSIONS A novel FPDI-MS technique has been developed by combining metal mesh and filter paper drilled with holes as the counter electrode and sample carrier. The corresponding improvement in analysis sensitivity facilitates the future expansion of FPDI-MS applications into different pesticides and other compounds in complex matrixes.
Collapse
Affiliation(s)
- Yajun Zheng
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, China
| | - Qianqian Zuo
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, China
| | - Zhicheng Xiang
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, China
| | - Yajie Huang
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, China
| | - Zhiping Zhang
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, China
| |
Collapse
|
5
|
Xiang Z, Zheng Y, Huang Y, Shi J, Zhang Z. Focusing Plasma Desorption/Ionization Mass Spectrometry. Anal Chem 2022; 94:17090-17101. [PMID: 36444961 DOI: 10.1021/acs.analchem.2c03237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A plasma-based source named focusing plasma desorption/ionization (FPDI) is described, which applies a high direct current voltage between a metal wire inside a polymeric hollow truncated cone and a piece of a one-sided coated conducting paper substrate. The conducting paper acts as both the counter electrode and the sample carrier. Upon the generation of a visible plasma beam, it would directly ionize the samples spotted on the conducting paper substrate or located around the plasma beam. The signal intensity of target analytes in mass spectrometric analysis is dependent highly on whether the conducting paper substrate is grounded or not, the type of conducting paper substrate, the inside diameter of the polymeric hollow truncated cone tip, the metal wire tip-to-polymer tip distance, the polymer tip-to-paper substrate distance, the applied voltage, and the helium flow rate. Based on the experimental observation, a plausible mechanism is proposed for the generation of the plasma beam from FPDI. Compared to the available low-temperature plasma, flowing atmospheric-pressure afterglow, and helium plasma ionization sources, FPDI has demonstrated higher sensitivity and better compatibility with commercial mass spectrometers without any extra power supplies. As a proof of concept, FPDI coupled with a mass spectrometer has also been applied for the discrimination of different brands of gasoline and determination of solid tablets and pesticides with limits of detection in the range of 2.2 to 30.7 ng mL-1.
Collapse
Affiliation(s)
- Zhicheng Xiang
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, Shaanxi 710065, China
| | - Yajun Zheng
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, Shaanxi 710065, China
| | - Yajie Huang
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, Shaanxi 710065, China
| | - Jun Shi
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, Shaanxi 710065, China
| | - Zhiping Zhang
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, Shaanxi 710065, China
| |
Collapse
|