1
|
Harshbarger CL. Harnessing the power of Microscale AcoustoFluidics: A perspective based on BAW cancer diagnostics. BIOMICROFLUIDICS 2024; 18:011304. [PMID: 38434238 PMCID: PMC10907075 DOI: 10.1063/5.0180158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Accepted: 02/05/2024] [Indexed: 03/05/2024]
Abstract
Cancer directly affects one in every three people, and mortality rates strongly correlate with the stage at which diagnosis occurs. Each of the multitude of methods used in cancer diagnostics has its own set of advantages and disadvantages. Two common drawbacks are a limited information value of image based diagnostic methods and high invasiveness when opting for methods that provide greater insight. Microfluidics offers a promising avenue for isolating circulating tumor cells from blood samples, offering high informational value at predetermined time intervals while being minimally invasive. Microscale AcoustoFluidics, an active method capable of manipulating objects within a fluid, has shown its potential use for the isolation and measurement of circulating tumor cells, but its full potential has yet to be harnessed. Extensive research has focused on isolating single cells, although the significance of clusters should not be overlooked and requires attention within the field. Moreover, there is room for improvement by designing smaller and automated devices to enhance user-friendliness and efficiency as illustrated by the use of bulk acoustic wave devices in cancer diagnostics. This next generation of setups and devices could minimize streaming forces and thereby enable the manipulation of smaller objects, thus aiding in the implementation of personalized oncology for the next generation of cancer treatments.
Collapse
Affiliation(s)
- C. L. Harshbarger
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland; Institute for Biomechanics, Swiss Federal Institute of Technology Zurich, Zurich, Switzerland; and Institute for Mechanical Systems, Swiss Federal Institute of Technology Zurich, Zurich, Switzerland
| |
Collapse
|
2
|
Wu D, Baresch D, Cook C, Ma Z, Duan M, Malounda D, Maresca D, Abundo MP, Lee J, Shivaei S, Mittelstein DR, Qiu T, Fischer P, Shapiro MG. Biomolecular actuators for genetically selective acoustic manipulation of cells. SCIENCE ADVANCES 2023; 9:eadd9186. [PMID: 36812320 PMCID: PMC9946353 DOI: 10.1126/sciadv.add9186] [Citation(s) in RCA: 26] [Impact Index Per Article: 26.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Accepted: 01/20/2023] [Indexed: 06/01/2023]
Abstract
The ability to physically manipulate specific cells is critical for the fields of biomedicine, synthetic biology, and living materials. Ultrasound has the ability to manipulate cells with high spatiotemporal precision via acoustic radiation force (ARF). However, because most cells have similar acoustic properties, this capability is disconnected from cellular genetic programs. Here, we show that gas vesicles (GVs)-a unique class of gas-filled protein nanostructures-can serve as genetically encodable actuators for selective acoustic manipulation. Because of their lower density and higher compressibility relative to water, GVs experience strong ARF with opposite polarity to most other materials. When expressed inside cells, GVs invert the cells' acoustic contrast and amplify the magnitude of their ARF, allowing the cells to be selectively manipulated with sound waves based on their genotype. GVs provide a direct link between gene expression and acoustomechanical actuation, opening a paradigm for selective cellular control in a broad range of contexts.
Collapse
Affiliation(s)
- Di Wu
- Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA
| | - Diego Baresch
- University of Bordeaux, CNRS, Bordeaux INP, I2M, UMR 5295, F-33400 Talence, France
| | - Colin Cook
- Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA
| | - Zhichao Ma
- Max Planck Institute for Intelligent Systems, Heisenbergstr. 3, 70569 Stuttgart, Germany
| | - Mengtong Duan
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Dina Malounda
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - David Maresca
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Maria P. Abundo
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Justin Lee
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Shirin Shivaei
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, CA, USA
| | - David R. Mittelstein
- Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA
| | - Tian Qiu
- Institute of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569 Stuttgart, Germany
| | - Peer Fischer
- Max Planck Institute for Medical Research, Jahnstrasse 29, 69120 Heidelberg, Germany
- Institute for Molecular Systems Engineering and Advanced Materials, Heidelberg University, INF 225, 69120 Heidelberg, Germany
| | - Mikhail G. Shapiro
- Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA
- Division of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, CA, USA
- Howard Hughes Medical Institute, California Institute of Technology, Pasadena, CA, USA
| |
Collapse
|
3
|
Harshbarger CL, Gerlt MS, Ghadamian JA, Bernardoni DC, Snedeker JG, Dual J. Optical feedback control loop for the precise and robust acoustic focusing of cells, micro- and nanoparticles. LAB ON A CHIP 2022; 22:2810-2819. [PMID: 35843222 DOI: 10.1039/d2lc00376g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Despite a long history and the vast number of applications demonstrated, very few market products incorporate acoustophoresis. Because a human operator must run and control a device during an experiment, most devices are limited to proof of concepts. On top of a possible detuning due to temperature changes, the human operator introduces a bias which reduces the reproducibility, performance and reliability of devices. To mitigate some of these problems, we propose an optical feedback control loop that optimizes the excitation frequency. We investigate the improvements that can be expected when a human operator is replaced for acoustic micro- and nanometer particle focusing experiments. Three experiments previously conducted in our group were taken as a benchmark. In addition to being automatic, this resulted in the feedback control loop displaying a superior performance compared to an experienced scientist in 1) improving the particle focusing by at least a factor of two for 5 μm diameter PS particles, 2) increasing the range of flow rates in which 1 μm diameter PS particles could be focused and 3) was even capable of focusing 600 nm diameter PS particles at a frequency of 1.72075 MHz. Furthermore, the feedback control loop is capable of focusing biological cells in one and two pressure nodes. The requirements for the feedback control loop are: an optical setup, a run-of-the-mill computer and a computer controllable function generator. Thus resulting in a cost-effective, high-throughput and automated method to rapidly increase the efficiency of established systems. The code for the feedback control loop is openly accessible and the authors explicitly wish that the community uses and modifies the feedback control loop to their own needs.
Collapse
Affiliation(s)
- Cooper L Harshbarger
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
- Institute for Biomechanics, Swiss Federal Institute of Technology Zurich, Zurich, Switzerland
- Institute for Mechanical Systems, Swiss Federal Institute of Technology Zurich, Zurich, Switzerland
| | - Michael S Gerlt
- Institute for Mechanical Systems, Swiss Federal Institute of Technology Zurich, Zurich, Switzerland
- Institute for Chemical and Bioengineering, Swiss Federal Institute of Technology Zurich, Zurich, Switzerland
| | - Jan A Ghadamian
- Institute for Mechanical Systems, Swiss Federal Institute of Technology Zurich, Zurich, Switzerland
| | - Davide C Bernardoni
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
- Institute for Biomechanics, Swiss Federal Institute of Technology Zurich, Zurich, Switzerland
| | - Jess G Snedeker
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
- Institute for Biomechanics, Swiss Federal Institute of Technology Zurich, Zurich, Switzerland
| | - Jürg Dual
- Institute for Mechanical Systems, Swiss Federal Institute of Technology Zurich, Zurich, Switzerland
| |
Collapse
|