1
|
Alver CG, Drabbe E, Ishahak M, Agarwal A. Roadblocks confronting widespread dissemination and deployment of Organs on Chips. Nat Commun 2024; 15:5118. [PMID: 38879554 PMCID: PMC11180125 DOI: 10.1038/s41467-024-48864-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Accepted: 05/16/2024] [Indexed: 06/19/2024] Open
Abstract
Organ on Chip platforms hold significant promise as alternatives to animal models or traditional cell cultures, both of which poorly recapitulate human pathophysiology and human level responses. Within the last 15 years, we have witnessed seminal scientific developments from academic laboratories, a flurry of startups and investments, and a genuine interest from pharmaceutical industry as well as regulatory authorities to translate these platforms. This Perspective identifies several fundamental design and process features that may act as roadblocks that prevent widespread dissemination and deployment of these systems, and provides a roadmap to help position this technology in mainstream drug discovery.
Collapse
Affiliation(s)
- Charles G Alver
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, USA
- Medical Scientist Training Program, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Emma Drabbe
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, USA
| | - Matthew Ishahak
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, USA
| | - Ashutosh Agarwal
- Department of Biomedical Engineering, University of Miami, Coral Gables, FL, USA.
- Desai Sethi Urology Institute, University of Miami Miller School of Medicine, Miami, FL, USA.
| |
Collapse
|
2
|
Orlowska MK, Krycer JR, Reid JD, Mills RJ, Doran MR, Hudson JE. A miniaturized culture platform for control of the metabolic environment. BIOMICROFLUIDICS 2024; 18:024101. [PMID: 38434908 PMCID: PMC10908563 DOI: 10.1063/5.0169143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Accepted: 02/05/2024] [Indexed: 03/05/2024]
Abstract
The heart is a metabolic "omnivore" and adjusts its energy source depending on the circulating metabolites. Human cardiac organoids, a three-dimensional in vitro model of the heart wall, are a useful tool to study cardiac physiology and pathology. However, cardiac tissue naturally experiences shear stress and nutrient fluctuations via blood flow in vivo, whilst in vitro models are conventionally cultivated in a static medium. This necessitates the regular refreshing of culture media, which creates acute cellular disturbances and large metabolic fluxes. To culture human cardiac organoids in a more physiological manner, we have developed a perfused bioreactor for cultures in a 96-well plate format. The designed bioreactor is easy to fabricate using a common culture plate and a 3D printer. Its open system allows for the use of traditional molecular biology techniques, prevents flow blockage issues, and provides easy access for sampling and cell assays. We hypothesized that a perfused culture would create more stable environment improving cardiac function and maturation. We found that lactate is rapidly produced by human cardiac organoids, resulting in large fluctuations in this metabolite under static culture. Despite this, neither medium perfusion in bioreactor culture nor lactate supplementation improved cardiac function or maturation. In fact, RNA sequencing revealed little change across the transcriptome. This demonstrates that cardiac organoids are robust in response to fluctuating environmental conditions under normal physiological conditions. Together, we provide a framework for establishing an easily accessible perfusion system that can be adapted to a range of miniaturized cell culture systems.
Collapse
|
3
|
Zhang F, Lin DSY, Rajasekar S, Sotra A, Zhang B. Pump-Less Platform Enables Long-Term Recirculating Perfusion of 3D Printed Tubular Tissues. Adv Healthc Mater 2023; 12:e2300423. [PMID: 37543836 DOI: 10.1002/adhm.202300423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 07/13/2023] [Indexed: 08/07/2023]
Abstract
The direction and pattern of fluid flow affect vascular structure and function, in which vessel-lining endothelial cells exhibit variable cellular morphologies and vessel remodeling by mechanosensing. To recapitulate this microenvironment, some approaches have been reported to successfully apply unidirectional flow on endothelial cells in organ-on-a-chip systems. However, these platforms encounter drawbacks such as the dependency on pumps or confinement to closed microfluidic channels. These constraints impede their synergy with advanced biofabrication techniques like 3D bioprinting, thereby curtailing the potential to introduce greater complexity into engineered tissues. Herein, a pumpless recirculating platform (UniPlate) that enables unidirectional media recirculation through 3D printed tubular tissues, is demonstrated.The device is made of polystyrene via injection molding in combination with 3D printed sacrifical gelatin templates. Tubular blood vessels with unidirectional perfusion are firstly engineered. Then the design is expanded to incorporate duo-recirculating flow for culturing vascularized renal proximal tubules with glucose reabsorption function. In addition to media recirculation, human monocyte recirculation in engineered blood vessels is also demonstrated for over 24 h, with minimal loss of cells, cell viability, and inflammatory activation. UniPlate can be a valuable tool to more precisely control the cellular microenvironment of organ-on-a-chip systems for drug discovery.
Collapse
Affiliation(s)
- Feng Zhang
- School of Biomedical Engineering, McMaster University, Hamilton, ON, L8S 4L8, Canada
| | - Dawn S Y Lin
- Department of Chemical Engineering, McMaster University, Hamilton, ON, L8S 4L8, Canada
| | - Shravanthi Rajasekar
- Department of Chemical Engineering, McMaster University, Hamilton, ON, L8S 4L8, Canada
| | - Alexander Sotra
- School of Biomedical Engineering, McMaster University, Hamilton, ON, L8S 4L8, Canada
| | - Boyang Zhang
- School of Biomedical Engineering, McMaster University, Hamilton, ON, L8S 4L8, Canada
- Department of Chemical Engineering, McMaster University, Hamilton, ON, L8S 4L8, Canada
| |
Collapse
|
4
|
Cliffe FE, Madden C, Costello P, Devitt S, Mukkunda SR, Keshava BB, Fearnhead HO, Vitkauskaite A, Dehkordi MH, Chingwaru W, Przyjalgowski M, Rebrova N, Lyons M. Mera: A scalable high throughput automated micro-physiological system. SLAS Technol 2023; 28:230-242. [PMID: 36708805 DOI: 10.1016/j.slast.2023.01.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 01/16/2023] [Accepted: 01/21/2023] [Indexed: 01/27/2023]
Abstract
There is an urgent need for scalable Microphysiological Systems (MPS's)1 that can better predict drug efficacy and toxicity at the preclinical screening stage. Here we present Mera, an automated, modular and scalable system for culturing and assaying microtissues with interconnected fluidics, inbuilt environmental control and automated image capture. The system presented has multiple possible fluidics modes. Of these the primary mode is designed so that cells may be matured into a desired microtissue type and in the secondary mode the fluid flow can be re-orientated to create a recirculating circuit composed of inter-connected channels to allow drugging or staining. We present data demonstrating the prototype system Mera using an Acetaminophen/HepG2 liver microtissue toxicity assay with Calcein AM and Ethidium Homodimer (EtHD1) viability assays. We demonstrate the functionality of the automated image capture system. The prototype microtissue culture plate wells are laid out in a 3 × 3 or 4 × 10 grid format with viability and toxicity assays demonstrated in both formats. In this paper we set the groundwork for the Mera system as a viable option for scalable microtissue culture and assay development.
Collapse
Affiliation(s)
- Finola E Cliffe
- Hooke Bio Ltd, L4A Smithstown Industrial Estate, Shannon, Co. Clare V14 XH92, Ireland
| | - Conor Madden
- Hooke Bio Ltd, L4A Smithstown Industrial Estate, Shannon, Co. Clare V14 XH92, Ireland
| | - Patrick Costello
- Hooke Bio Ltd, L4A Smithstown Industrial Estate, Shannon, Co. Clare V14 XH92, Ireland
| | - Shane Devitt
- Hooke Bio Ltd, L4A Smithstown Industrial Estate, Shannon, Co. Clare V14 XH92, Ireland
| | - Sumir Ramesh Mukkunda
- Hooke Bio Ltd, L4A Smithstown Industrial Estate, Shannon, Co. Clare V14 XH92, Ireland
| | | | - Howard O Fearnhead
- Pharmacology and Therapeutics, Biomedical Sciences, Dangan, NUI Galway, Galway, Ireland
| | - Aiste Vitkauskaite
- Pharmacology and Therapeutics, Biomedical Sciences, Dangan, NUI Galway, Galway, Ireland
| | - Mahshid H Dehkordi
- Pharmacology and Therapeutics, Biomedical Sciences, Dangan, NUI Galway, Galway, Ireland
| | - Walter Chingwaru
- Pharmacology and Therapeutics, Biomedical Sciences, Dangan, NUI Galway, Galway, Ireland
| | - Milosz Przyjalgowski
- Centre for Advanced Photonics and Process Analysis, Munster Technological University, Cork T12 P928, Ireland
| | - Natalia Rebrova
- Centre for Advanced Photonics and Process Analysis, Munster Technological University, Cork T12 P928, Ireland
| | - Mark Lyons
- Hooke Bio Ltd, L4A Smithstown Industrial Estate, Shannon, Co. Clare V14 XH92, Ireland.
| |
Collapse
|
5
|
A Cataño J, Farthing S, Mascarenhas Z, Lake N, Yarlagadda PKDV, Li Z, Toh YC. A User-Centric 3D-Printed Modular Peristaltic Pump for Microfluidic Perfusion Applications. MICROMACHINES 2023; 14:mi14050930. [PMID: 37241553 DOI: 10.3390/mi14050930] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 04/17/2023] [Accepted: 04/23/2023] [Indexed: 05/28/2023]
Abstract
Microfluidic organ-on-a-chip (OoC) technology has enabled studies on dynamic physiological conditions as well as being deployed in drug testing applications. A microfluidic pump is an essential component to perform perfusion cell culture in OoC devices. However, it is challenging to have a single pump that can fulfil both the customization function needed to mimic a myriad of physiological flow rates and profiles found in vivo and multiplexing requirements (i.e., low cost, small footprint) for drug testing operations. The advent of 3D printing technology and open-source programmable electronic controllers presents an opportunity to democratize the fabrication of mini-peristaltic pumps suitable for microfluidic applications at a fraction of the cost of commercial microfluidic pumps. However, existing 3D-printed peristaltic pumps have mainly focused on demonstrating the feasibility of using 3D printing to fabricate the structural components of the pump and neglected user experience and customization capability. Here, we present a user-centric programmable 3D-printed mini-peristaltic pump with a compact design and low manufacturing cost (~USD 175) suitable for perfusion OoC culture applications. The pump consists of a user-friendly, wired electronic module that controls the operation of a peristaltic pump module. The peristaltic pump module comprises an air-sealed stepper motor connected to a 3D-printed peristaltic assembly, which can withstand the high-humidity environment of a cell culture incubator. We demonstrated that this pump allows users to either program the electronic module or use different-sized tubing to deliver a wide range of flow rates and flow profiles. The pump also has multiplexing capability as it can accommodate multiple tubing. The performance and user-friendliness of this low-cost, compact pump can be easily deployed for various OoC applications.
Collapse
Affiliation(s)
- Jorge A Cataño
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane 4000, Australia
- Centre for Biomedical Technologies, Queensland University of Technology, Kelvin Grove 4059, Australia
| | - Steven Farthing
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane 4000, Australia
| | - Zeus Mascarenhas
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane 4000, Australia
| | - Nathaniel Lake
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane 4000, Australia
| | - Prasad K D V Yarlagadda
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane 4000, Australia
- Centre for Biomedical Technologies, Queensland University of Technology, Kelvin Grove 4059, Australia
- School of Engineering, University of Southern Queensland, Springfield Central 4300, Australia
| | - Zhiyong Li
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane 4000, Australia
- Centre for Biomedical Technologies, Queensland University of Technology, Kelvin Grove 4059, Australia
| | - Yi-Chin Toh
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane 4000, Australia
- Centre for Biomedical Technologies, Queensland University of Technology, Kelvin Grove 4059, Australia
- Max Planck Queensland Centre (MPQC) for the Materials Science of Extracellular Matrices, Queensland University of Technology, Kelvin Grove 4059, Australia
- Centre for Microbiome Research, Queensland University of Technology, Woolloongabba 4102, Australia
| |
Collapse
|
6
|
Closed-loop Control Systems for Pumps used in Portable Analytical Systems. J Chromatogr A 2023; 1695:463931. [PMID: 37011525 DOI: 10.1016/j.chroma.2023.463931] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 02/27/2023] [Accepted: 03/14/2023] [Indexed: 03/17/2023]
Abstract
The demand for accurate control of the flowrate/pressure in chemical analytical systems has given rise to the adoption of mechatronic approaches in analytical instruments. A mechatronic device is a synergistic system which combines mechanical, electronic, computer and control components. In the development of portable analytical devices, considering the instrument as a mechatronic system can be useful to mitigate compromises made to decrease space, weight, or power consumption. Fluid handling is important for reliability, however, commonly utilized platforms such as syringe and peristaltic pumps are typically characterized by flow/pressure fluctuations and slow responses. Closed loop control systems have been used effectively to decrease the difference between desired and realized fluidic output. This review discusses the way control systems have been implemented for enhanced fluidic control, categorized by pump type. Advanced control strategies used to enhance the transient and the steady state responses are discussed, along with examples of their implementation in portable analytical systems. The review is concluded with the outlook that the challenge in adequately expressing the complexity and dynamics of the fluidic network as a mathematical model has yielded a trend towards the adoption of experimentally informed models and machine learning approaches.
Collapse
|
7
|
Duan K, Orabi M, Warchock A, Al-Akraa Z, Ajami Z, Chun TH, Lo JF. Monolithically 3D-Printed Microfluidics with Embedded µTesla Pump. MICROMACHINES 2023; 14:mi14020237. [PMID: 36837937 PMCID: PMC9965163 DOI: 10.3390/mi14020237] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/03/2022] [Revised: 01/10/2023] [Accepted: 01/11/2023] [Indexed: 06/08/2023]
Abstract
Microfluidics has earned a reputation for providing numerous transformative but disconnected devices and techniques. Active research seeks to address this challenge by integrating microfluidic components, including embedded miniature pumps. However, a significant portion of existing microfluidic integration relies on the time-consuming manual fabrication that introduces device variations. We put forward a framework for solving this disconnect by combining new pumping mechanics and 3D printing to demonstrate several novel, integrated and wirelessly driven microfluidics. First, we characterized the simplicity and performance of printed microfluidics with a minimum feature size of 100 µm. Next, we integrated a microtesla (µTesla) pump to provide non-pulsatile flow with reduced shear stress on beta cells cultured on-chip. Lastly, the integration of radio frequency (RF) device and a hobby-grade brushless motor completed a self-enclosed platform that can be remotely controlled without wires. Our study shows how new physics and 3D printing approaches not only provide better integration but also enable novel cell-based studies to advance microfluidic research.
Collapse
Affiliation(s)
- Kai Duan
- Department of Mechanical Engineering, University of Michigan–Dearborn, Dearborn, MI 48128, USA
| | - Mohamad Orabi
- Department of Mechanical Engineering, University of Michigan–Dearborn, Dearborn, MI 48128, USA
| | - Alexus Warchock
- Department of Mechanical Engineering, University of Michigan–Dearborn, Dearborn, MI 48128, USA
| | - Zaynab Al-Akraa
- Department of Mechanical Engineering, University of Michigan–Dearborn, Dearborn, MI 48128, USA
| | - Zeinab Ajami
- Department of Mechanical Engineering, University of Michigan–Dearborn, Dearborn, MI 48128, USA
| | - Tae-Hwa Chun
- Department of Internal Medicine, University of Michigan Medical School, Ann Arbor, MI 48109, USA
| | - Joe F. Lo
- Department of Mechanical Engineering, University of Michigan–Dearborn, Dearborn, MI 48128, USA
| |
Collapse
|
8
|
Aubry G, Lee HJ, Lu H. Advances in Microfluidics: Technical Innovations and Applications in Diagnostics and Therapeutics. Anal Chem 2023; 95:444-467. [PMID: 36625114 DOI: 10.1021/acs.analchem.2c04562] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Affiliation(s)
- Guillaume Aubry
- School of Chemical & Biomolecular Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Hyun Jee Lee
- School of Chemical & Biomolecular Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Hang Lu
- School of Chemical & Biomolecular Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States.,Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| |
Collapse
|
9
|
Rogal J, Roosz J, Teufel C, Cipriano M, Xu R, Eisler W, Weiss M, Schenke‐Layland K, Loskill P. Autologous Human Immunocompetent White Adipose Tissue-on-Chip. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2104451. [PMID: 35466539 PMCID: PMC9218765 DOI: 10.1002/advs.202104451] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Revised: 03/03/2022] [Indexed: 05/07/2023]
Abstract
Obesity and associated diseases, such as diabetes, have reached epidemic proportions globally. In this era of "diabesity", white adipose tissue (WAT) has become a target of high interest for therapeutic strategies. To gain insights into mechanisms of adipose (patho-)physiology, researchers traditionally relied on animal models. Leveraging Organ-on-Chip technology, a microphysiological in vitro model of human WAT is introduced: a tailored microfluidic platform featuring vasculature-like perfusion that integrates 3D tissues comprising all major WAT-associated cellular components (mature adipocytes, organotypic endothelial barriers, stromovascular cells including adipose tissue macrophages) in an autologous manner and recapitulates pivotal WAT functions, such as energy storage and mobilization as well as endocrine and immunomodulatory activities. A precisely controllable bottom-up approach enables the generation of a multitude of replicates per donor circumventing inter-donor variability issues and paving the way for personalized medicine. Moreover, it allows to adjust the model's degree of complexity via a flexible mix-and-match approach. This WAT-on-Chip system constitutes the first human-based, autologous, and immunocompetent in vitro adipose tissue model that recapitulates almost full tissue heterogeneity and can become a powerful tool for human-relevant research in the field of metabolism and its associated diseases as well as for compound testing and personalized- and precision medicine applications.
Collapse
Affiliation(s)
- Julia Rogal
- Department for Microphysiological Systems, Institute of Biomedical EngineeringEberhard Karls University TübingenÖsterbergstr. 3Tübingen72074Germany
- Fraunhofer Institute for Interfacial Engineering and Biotechnology IGBNobelstr. 12Stuttgart70569Germany
| | - Julia Roosz
- NMI Natural and Medical Sciences Institute at the University of TübingenMarkwiesenstr. 55Reutlingen72770Germany
| | - Claudia Teufel
- Department for Microphysiological Systems, Institute of Biomedical EngineeringEberhard Karls University TübingenÖsterbergstr. 3Tübingen72074Germany
| | - Madalena Cipriano
- Department for Microphysiological Systems, Institute of Biomedical EngineeringEberhard Karls University TübingenÖsterbergstr. 3Tübingen72074Germany
- 3R‐Center for In vitro Models and Alternatives to Animal TestingEberhard Karls University TübingenÖsterbergstr. 3Tübingen72074Germany
| | - Raylin Xu
- Fraunhofer Institute for Interfacial Engineering and Biotechnology IGBNobelstr. 12Stuttgart70569Germany
- Harvard Medical School (HMS)25 Shattuck StBostonMA02115USA
| | - Wiebke Eisler
- Clinic for PlasticReconstructiveHand and Burn SurgeryBG Trauma CenterEberhard Karls University TübingenSchnarrenbergstraße 95Tübingen72076Germany
| | - Martin Weiss
- NMI Natural and Medical Sciences Institute at the University of TübingenMarkwiesenstr. 55Reutlingen72770Germany
- Department of Women's HealthEberhard Karls University TübingenCalwerstrasse 7Tübingen72076Germany
| | - Katja Schenke‐Layland
- NMI Natural and Medical Sciences Institute at the University of TübingenMarkwiesenstr. 55Reutlingen72770Germany
- Department of Medicine/CardiologyCardiovascular Research LaboratoriesDavid Geffen School of Medicine at UCLA675 Charles E. Young Drive South, MRL 3645Los AngelesCA90095USA
- Cluster of Excellence iFIT (EXC2180) “Image‐Guided and Functionally Instructed Tumor Therapies”Eberhard Karls University TuebingenRöntgenweg 11Tuebingen72076Germany
- Department for Medical Technologies and Regenerative MedicineInstitute of Biomedical EngineeringEberhard Karls University TübingenSilcherstr. 7/1Tübingen72076Germany
| | - Peter Loskill
- Department for Microphysiological Systems, Institute of Biomedical EngineeringEberhard Karls University TübingenÖsterbergstr. 3Tübingen72074Germany
- NMI Natural and Medical Sciences Institute at the University of TübingenMarkwiesenstr. 55Reutlingen72770Germany
- 3R‐Center for In vitro Models and Alternatives to Animal TestingEberhard Karls University TübingenÖsterbergstr. 3Tübingen72074Germany
| |
Collapse
|
10
|
Perfusion in Organ-on-Chip Models and Its Applicability to the Replication of Spermatogenesis In Vitro. Int J Mol Sci 2022; 23:ijms23105402. [PMID: 35628214 PMCID: PMC9141186 DOI: 10.3390/ijms23105402] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 05/05/2022] [Accepted: 05/06/2022] [Indexed: 02/01/2023] Open
Abstract
Organ/organoid-on-a-chip (OoC) technologies aim to replicate aspects of the in vivo environment in vitro, at the scale of microns. Mimicking the spatial in vivo structure is important and can provide a deeper understanding of the cell–cell interactions and the mechanisms that lead to normal/abnormal function of a given organ. It is also important for disease models and drug/toxin testing. Incorporating active fluid flow in chip models enables many more possibilities. Active flow can provide physical cues, improve intercellular communication, and allow for the dynamic control of the environment, by enabling the efficient introduction of biological factors, drugs, or toxins. All of this is in addition to the fundamental role of flow in supplying nutrition and removing waste metabolites. This review presents an overview of the different types of fluid flow and how they are incorporated in various OoC models. The review then describes various methods and techniques of incorporating perfusion networks into OoC models, including self-assembly, bioprinting techniques, and utilizing sacrificial gels. The second part of the review focuses on the replication of spermatogenesis in vitro; the complex process whereby spermatogonial stem cells differentiate into mature sperm. A general overview is given of the various approaches that have been used. The few studies that incorporated microfluidics or vasculature are also described. Finally, a future perspective is given on elements from perfusion-based models that are currently used in models of other organs and can be applied to the field of in vitro spermatogenesis. For example, adopting tubular blood vessel models to mimic the morphology of the seminiferous tubules and incorporating vasculature in testis-on-a-chip models. Improving these models would improve our understanding of the process of spermatogenesis. It may also potentially provide novel therapeutic strategies for pre-pubertal cancer patients who need aggressive chemotherapy that can render them sterile, as well asfor a subset of non-obstructive azoospermic patients with maturation arrest, whose testes do not produce sperm but still contain some of the progenitor cells.
Collapse
|
11
|
Shroff T, Aina K, Maass C, Cipriano M, Lambrecht J, Tacke F, Mosig A, Loskill P. Studying metabolism with multi-organ chips: new tools for disease modelling, pharmacokinetics and pharmacodynamics. Open Biol 2022; 12:210333. [PMID: 35232251 PMCID: PMC8889168 DOI: 10.1098/rsob.210333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
Non-clinical models to study metabolism including animal models and cell assays are often limited in terms of species translatability and predictability of human biology. This field urgently requires a push towards more physiologically accurate recapitulations of drug interactions and disease progression in the body. Organ-on-chip systems, specifically multi-organ chips (MOCs), are an emerging technology that is well suited to providing a species-specific platform to study the various types of metabolism (glucose, lipid, protein and drug) by recreating organ-level function. This review provides a resource for scientists aiming to study human metabolism by providing an overview of MOCs recapitulating aspects of metabolism, by addressing the technical aspects of MOC development and by providing guidelines for correlation with in silico models. The current state and challenges are presented for two application areas: (i) disease modelling and (ii) pharmacokinetics/pharmacodynamics. Additionally, the guidelines to integrate the MOC data into in silico models could strengthen the predictive power of the technology. Finally, the translational aspects of metabolizing MOCs are addressed, including adoption for personalized medicine and prospects for the clinic. Predictive MOCs could enable a significantly reduced dependence on animal models and open doors towards economical non-clinical testing and understanding of disease mechanisms.
Collapse
Affiliation(s)
- Tanvi Shroff
- NMI Natural and Medical Sciences Institute at the University of Tübingen, Reutlingen, Germany,Department for Microphysiological Systems, Institute for Biomedical Engineering, Faculty of Medicine, Eberhard Karls University Tübingen, Österbergstraße 3, 72074 Tübingen, Germany
| | - Kehinde Aina
- Institute of Biochemistry II, Center for Sepsis Control and Care, Jena University Hospital, Jena, Germany
| | | | - Madalena Cipriano
- Department for Microphysiological Systems, Institute for Biomedical Engineering, Faculty of Medicine, Eberhard Karls University Tübingen, Österbergstraße 3, 72074 Tübingen, Germany
| | - Joeri Lambrecht
- Department of Hepatology and Gastroenterology, Charité University Medicine Berlin, Campus Virchow Klinikum and Campus Charité Mitte, Berlin, Germany
| | - Frank Tacke
- Department of Hepatology and Gastroenterology, Charité University Medicine Berlin, Campus Virchow Klinikum and Campus Charité Mitte, Berlin, Germany
| | - Alexander Mosig
- Institute of Biochemistry II, Center for Sepsis Control and Care, Jena University Hospital, Jena, Germany
| | - Peter Loskill
- NMI Natural and Medical Sciences Institute at the University of Tübingen, Reutlingen, Germany,Department for Microphysiological Systems, Institute for Biomedical Engineering, Faculty of Medicine, Eberhard Karls University Tübingen, Österbergstraße 3, 72074 Tübingen, Germany,3R-Center for In vitro Models and Alternatives to Animal Testing, Eberhard Karls University Tübingen, Tübingen, Germany
| |
Collapse
|
12
|
An Integrated Pulsation-Free, Backflow-Free Micropump Using the Analog Waveform-Driven Braille Actuator. MICROMACHINES 2022; 13:mi13020294. [PMID: 35208418 PMCID: PMC8879040 DOI: 10.3390/mi13020294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 02/02/2022] [Accepted: 02/11/2022] [Indexed: 11/17/2022]
Abstract
The widespread adoption of long-term organs-on-a-chip culture necessitates both active perfusions that mimic physiological flow conditions and minimization of the complexity of microfluidic system and fluid handling. In particular, flow in microtissue such as microvascular is free of pulsation and backflow. The refreshable Braille actuator-based integrated microfluidic system can be employed with simple microchannels and setups. However, due to high pulsatile flow and backflow, ordinary Braille-driven micropumps generate non-physiological flow conditions. We have described a simple method for creating steady flow employing Braille actuators driven with a high-voltage analog waveform, called “constant flow waveform”, without incorporating complicated structures into the microchannel or actuator. We determined the constant flow waveform by measuring volume change of microchannel caused by actuated Braille pins using a conventional fluorescent dye and microscope. Using the constant flow waveform, we demonstrated that a Braille-driven pump reduced pulsating flow by 79% and backflow by 63% compared to conventional Braille-driven pump. Furthermore, we demonstrated that a parallel pair of three-stranded pin pumps effectively eliminated backflow by driving two pumps with the constant flow waveform half-cycle shifted to each other. Moreover, by raising the driving frequency, we could increase the average flow rate to ~2× higher than previously reported flow rate of a typical Braille-driven micropump.
Collapse
|