1
|
Zou L, Li M, Wang X, Ye M, Chen L, Wang L, Song Y. A "turn-on" fluorescent sensor based on three-component covalent organic framework for trace water detection. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2024; 311:123978. [PMID: 38330759 DOI: 10.1016/j.saa.2024.123978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Revised: 01/10/2024] [Accepted: 01/28/2024] [Indexed: 02/10/2024]
Abstract
Trace amount of H2O is difficult to eliminate in laboratory environments and chemical industries as impurities. In some chemical reactions, trace amount of H2O can alter final reaction products, yield, and selectivity. So, the detection of trace H2O is very important. Herein, a series of TFPT[X]-BMTH- covalent organic frameworks (COFs) (X = 0, 33, 50, 67, 100 %) with intramolecular charge transfer effect (ICT) and aggregate-induced emission (AIE) characteristics were synthesized by amino-aldehyde condensation reaction between 2,5-bis(2-methoxyethoxy)terephthalohydrazide (BMTH)/ 1,3,5-tris(p-formylphenyl)benzene (TFPB) and 4,4',4''-(1,3,5-triazine-2,4,6-triyl)tribenzaldehyde (TFPT). By changing TFPT' content in TFPT[X]-BMTH-COFs, the ICT and AIE of TFPT[X]-BMTH-COFs can be controlled, and accordingly the response to trace H2O can be adjusted. A H2O sensor based on TFPT[67]-BMTH-COF with a wide linear range from 0 wt% to 0.5 wt% was developed and the detection limit was 0.00007 wt%. In addition, a portable fluorescent test paper based on TFPT[67]-BMTH-COF for visual detection of trace H2O in honey samples and salt was constructed. This work has important guiding significance for the development of fluorescent probes for the visual detection of trace water.
Collapse
Affiliation(s)
- Liangmei Zou
- Key Lab of Fluorine and Silicon for Energy Materials and Chemistry of Ministry of Education, College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang 330022, China
| | - Mengyao Li
- Key Lab of Fluorine and Silicon for Energy Materials and Chemistry of Ministry of Education, College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang 330022, China
| | - Xinyi Wang
- Key Lab of Fluorine and Silicon for Energy Materials and Chemistry of Ministry of Education, College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang 330022, China
| | - Meiling Ye
- Key Lab of Fluorine and Silicon for Energy Materials and Chemistry of Ministry of Education, College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang 330022, China
| | - Lili Chen
- Key Lab of Fluorine and Silicon for Energy Materials and Chemistry of Ministry of Education, College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang 330022, China
| | - Li Wang
- Key Lab of Fluorine and Silicon for Energy Materials and Chemistry of Ministry of Education, College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang 330022, China
| | - Yonghai Song
- Key Lab of Fluorine and Silicon for Energy Materials and Chemistry of Ministry of Education, College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang 330022, China.
| |
Collapse
|
2
|
Marschick G, Pelini J, Gabbrielli T, Cappelli F, Weih R, Knötig H, Koeth J, Höfling S, De Natale P, Strasser G, Borri S, Hinkov B. Mid-infrared Ring Interband Cascade Laser: Operation at the Standard Quantum Limit. ACS PHOTONICS 2024; 11:395-403. [PMID: 38405392 PMCID: PMC10885206 DOI: 10.1021/acsphotonics.3c01159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 12/26/2023] [Accepted: 12/27/2023] [Indexed: 02/27/2024]
Abstract
Many precision applications in the mid-infrared spectral range have strong constraints based on quantum effects that are expressed in particular noise characteristics. They limit, e.g., sensitivity and resolution of mid-infrared imaging and spectroscopic systems as well as the bit-error rate in optical free-space communication. Interband cascade lasers (ICLs) are a class of mid-infrared lasers exploiting interband transitions in type-II band alignment geometry. They are currently gaining significant importance for mid-infrared applications from < 3 to > 6 μm wavelength, enabled by novel types of high-performance ICLs such as ring-cavity devices. Their noise behavior is an important feature that still needs to be thoroughly analyzed, including its potential reduction with respect to the shot-noise limit. In this work, we provide a comprehensive characterization of λ = 3.8 μm-emitting, continuous-wave ring ICLs operating at room temperature. It is based on an in-depth study of their main physical intensity noise features such as their bias-dependent intensity noise power spectral density and relative intensity noise. We obtained shot-noise-limited statistics for Fourier frequencies above 100 kHz. This is an important result for precision applications, e.g., interferometry or advanced spectroscopy, which benefit from exploiting the advantage of using such a shot-noise-limited source, enhancing the setup sensitivity. Moreover, it is an important feature for novel quantum optics schemes, including testing specific light states below the shot-noise level, such as squeezed states.
Collapse
Affiliation(s)
- Georg Marschick
- TU
Wien—Institute of Solid State Electronics & Center for
Micro- and Nanostructures, Gußhausstraße 25-25a, Vienna 1040, Austria
| | - Jacopo Pelini
- University
of Naples Federico II, Corso Umberto I 40, Napoli 80138, Italy
- CNR-INO—Istituto
Nazionale di Ottica, Largo Fermi, 6, Firenze, FI 50125, Italy
| | - Tecla Gabbrielli
- CNR-INO—Istituto
Nazionale di Ottica, Via Carrara, 1, Sesto Fiorentino, Florence 50019, Italy
- LENS—European
Laboratory for Non-Linear Spectroscopy, Via Carrara, 1, Sesto Fiorentino, Florence 50019, Italy
| | - Francesco Cappelli
- CNR-INO—Istituto
Nazionale di Ottica, Via Carrara, 1, Sesto Fiorentino, Florence 50019, Italy
- LENS—European
Laboratory for Non-Linear Spectroscopy, Via Carrara, 1, Sesto Fiorentino, Florence 50019, Italy
| | - Robert Weih
- nanoplus
Nanosystems and Technologies GmbH, Oberer Kirschberg 4, Gerbrunn 97218, Germany
| | - Hedwig Knötig
- TU
Wien—Institute of Solid State Electronics & Center for
Micro- and Nanostructures, Gußhausstraße 25-25a, Vienna 1040, Austria
| | - Johannes Koeth
- nanoplus
Nanosystems and Technologies GmbH, Oberer Kirschberg 4, Gerbrunn 97218, Germany
| | - Sven Höfling
- Julius-Maximilians-Universität
Würzburg—Physikalisches Institut, Lehrstuhl für Technische Physik, Am Hubland, Würzburg 97074, Germany
| | - Paolo De Natale
- CNR-INO—Istituto
Nazionale di Ottica, Largo Fermi, 6, Firenze, FI 50125, Italy
- CNR-INO—Istituto
Nazionale di Ottica, Via Carrara, 1, Sesto Fiorentino, Florence 50019, Italy
- LENS—European
Laboratory for Non-Linear Spectroscopy, Via Carrara, 1, Sesto Fiorentino, Florence 50019, Italy
- INFN—Istituto
Nazionale di Fisica Nucleare, Via Sansone, 1, Sesto Fiorentino, Florence 50019, Italy
| | - Gottfried Strasser
- TU
Wien—Institute of Solid State Electronics & Center for
Micro- and Nanostructures, Gußhausstraße 25-25a, Vienna 1040, Austria
| | - Simone Borri
- CNR-INO—Istituto
Nazionale di Ottica, Via Carrara, 1, Sesto Fiorentino, Florence 50019, Italy
- LENS—European
Laboratory for Non-Linear Spectroscopy, Via Carrara, 1, Sesto Fiorentino, Florence 50019, Italy
- INFN—Istituto
Nazionale di Fisica Nucleare, Via Sansone, 1, Sesto Fiorentino, Florence 50019, Italy
| | - Borislav Hinkov
- TU
Wien—Institute of Solid State Electronics & Center for
Micro- and Nanostructures, Gußhausstraße 25-25a, Vienna 1040, Austria
| |
Collapse
|
3
|
Qiu L, Saha M, Kraft S, Dziekonski ET, Welch CJ, Dai Y, Kaerner A, Cooks RG. Quantitative Determination of Water in Organic Liquids by Ambient Mass Spectrometry. Angew Chem Int Ed Engl 2023; 62:e202310884. [PMID: 37740943 DOI: 10.1002/anie.202310884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 08/31/2023] [Accepted: 09/18/2023] [Indexed: 09/25/2023]
Abstract
This study uses a rapid tandem mass-spectrometry method to determine water content in complex organic solutions. Emphasis is placed on trace-water analysis by a fast and accurate alternative to the Karl-Fischer method. In this new method, water is captured by a charge-labeled molecular probe. Water binds strongly with high specificity to the strongly electrophilic aldehyde site in a charge-labelled molecule (N-methylpyridinium); competitive binding by other analytes is effectively discriminated against in the mass-measurement step. Quantitative determinations are made over a wide concentration range, 0.001 % (10 ppm) to 99 %, with better than 10 % relative standard deviation, along with short (1 min) analysis times using small sample volumes (several μL). Applications include water measurement in simple organic solvents, for example, deuterated solvents, as well as in complex mixtures, for example, organic reaction mixtures. Additionally, this method allows for water monitoring in levitated droplets. Mechanistic investigations into the impact of water on important chemical processes in organic synthesis and environmental science are reported.
Collapse
Affiliation(s)
- Lingqi Qiu
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA
| | - Mousumi Saha
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA
| | | | - Eric T Dziekonski
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA
| | - Christopher J Welch
- Indiana Consortium for Analytical Science & Engineering (ICASE), Indianapolis, IN 46202, USA
| | - Yumin Dai
- Department of Analytical Development, Takeda Development Center Americas, Inc., Cambridge, MA 02139, USA
| | | | - R Graham Cooks
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA
| |
Collapse
|