1
|
Mirlohi MS, Pishbin E, Dezhkam R, Kiani MJ, Shamloo A, Salami S. Innovative PNA-LB mediated allele-specific LAMP for KRAS mutation profiling on a compact lab-on-a-disc device. Talanta 2024; 276:126224. [PMID: 38772176 DOI: 10.1016/j.talanta.2024.126224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Revised: 04/24/2024] [Accepted: 05/05/2024] [Indexed: 05/23/2024]
Abstract
Tailored healthcare, an approach focused on individual patients, requires integrating emerging interdisciplinary technologies to develop accurate and user-friendly diagnostic tools. KRAS mutations, prevalent in various common cancers, are crucial determinants in selecting patients for novel KRAS inhibitor therapies. This study presents a novel state-of-the-art Lab-on-a-Disc system utilizing peptide nucleic acids-loop backward (PNA-LB) mediated allele-specific loop-mediated isothermal amplification (LAMP) for detecting the frequent G12D KRAS mutation, signifying its superiority over alternative mutation detection approaches. The designed Lab-on-a-Disc system demonstrated exceptional preclinical and technical precision, accuracy, and versatility. By applying varying cutoff values to PNA- LB LAMP reactions, the assay's sensitivity and specificity were increased by 80 % and 90 %, respectively. The device's key advantages include a robust microfluidic Lab-on-a-Disc design, precise rotary control, and a cutting-edge induction heating module. These features enable multiplexing of LAMP reactions with high reproducibility and repeatability, with CV% values less than 3.5 % and 5.5 %, respectively. The device offers several methods for accurate endpoint result detection, including naked-eye observation, RGB image analysis using Python code, and time of fluorescence (Tf) values. Preclinical specificity and sensitivity, assessed using different cutoffs for Eva-Green fluorescence Tf values and pH-sensitive dyes, demonstrated comparable performance to the best standard methods. Overall, this study represents a significant step towards tailoring treatment strategies for cancer patients through precise and efficient mutation detection technologies.
Collapse
Affiliation(s)
- Maryam Sadat Mirlohi
- Clinical Biochemistry Department, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Esmail Pishbin
- Bio-microfluidics Laboratory, Department of Electrical Engineering and Information Technology, Iranian Research Organization for Science and Technology, Tehran, Iran.
| | - Rasool Dezhkam
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran; Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Mohammad Javad Kiani
- School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran
| | - Amir Shamloo
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
| | - Siamak Salami
- Clinical Biochemistry Department, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
2
|
Dong C, Li F, Sun Y, Long D, Chen C, Li M, Wei T, Martins RP, Chen T, Mak PI. A syndromic diagnostic assay on a macrochannel-to-digital microfluidic platform for automatic identification of multiple respiratory pathogens. LAB ON A CHIP 2024; 24:3850-3862. [PMID: 37961846 DOI: 10.1039/d3lc00728f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2023]
Abstract
The worldwide COVID-19 pandemic has changed people's lives and the diagnostic landscape. The nucleic acid amplification test (NAT) as the gold standard for SARS-CoV-2 detection has been applied in containing its transmission. However, there remains a lack of an affordable on-site detection system at resource-limited areas. In this study, a low cost "sample-in-answer-out" system incorporating nucleic acid extraction, purification, and amplification was developed on a single macrochannel-to-digital microfluidic chip. The macrochannel fluidic subsystem worked as a world-to-chip interface receiving 500-1000 μL raw samples, which then underwent bead-based extraction and purification processes before being delivered to DMF. Electrodes actuate an eluent dispensed to eight independent droplets for reverse transcription quantitative polymerase chain reaction (RT-qPCR). By reading with 4 florescence channels, the system can accommodate a maximum of 32 detection targets. To evaluate the proposed platform, a comprehensive assessment was conducted on the microfluidic chip as well as its functional components (i.e., extraction and amplification). The platform demonstrated a superior performance. In particular, using clinical specimens, the chip targeting SARS-CoV-2 and Flu A/B exhibited 100% agreement with off-chip diagnoses. Furthermore, the fabrication of chips is ready for scaled-up manufacturing and they are cost-effective for disposable use since they are assembled using a printed circuit board (PCB) and prefabricated blocks. Overall, the macrochannel-to-digital microfluidic platform coincides with the requirements of point-of-care testing (POCT) because of its advantages: low-cost, ease of use, comparable sensitivity and specificity, and availability for mass production.
Collapse
Affiliation(s)
- Cheng Dong
- School of Intelligent Systems Science and Engineering/JNU-Industry School of Artificial Intelligence, Jinan University, Zhuhai 519000, China
| | - Fei Li
- Department of Biomedical Engineering, Jinan University, Guangzhou, 510632, China
- Digifluidic Biotech Ltd., Zhuhai 519000, China.
| | - Yun Sun
- Digifluidic Biotech Ltd., Zhuhai 519000, China.
| | - Dongling Long
- Zhuhai Center for Disease Control and Prevention, Zhuhai 519087, China
| | - Chunzhao Chen
- Advanced Interdisciplinary Institute of Environment and Ecology, Beijing Normal University, Zhu Hai 519087, China
| | - Mengyan Li
- Department of Chemistry and Environmental Science, New Jersey Institute of Technology, Newark, 07102, USA
| | - Tao Wei
- Department of Bioengineering, College of Food Science, South China Agricultural University, Guangzhou, 510640, China
- Pan Asia (Jiangmen) Institute of Biological Engineering and Health, Jiangmen, 529080, China
| | - Rui P Martins
- State-Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Taipa, Macau SAR, 999078, China.
| | | | - Pui-In Mak
- State-Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Taipa, Macau SAR, 999078, China.
- Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, 999078, China
| |
Collapse
|
3
|
Zhang R, Zhang C, Fan X, Au Yeung CCK, Li H, Lin H, Shum HC. A droplet robotic system enabled by electret-induced polarization on droplet. Nat Commun 2024; 15:6220. [PMID: 39043732 PMCID: PMC11266649 DOI: 10.1038/s41467-024-50520-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Accepted: 07/12/2024] [Indexed: 07/25/2024] Open
Abstract
Robotics for scientific research are evolving from grasping macro-scale solid materials to directly actuating micro-scale liquid samples. However, current liquid actuation mechanisms often restrict operable liquid types or compromise the activity of biochemical samples by introducing interfering mediums. Here, we propose a robotic liquid handling system enabled by a novel droplet actuation mechanism, termed electret-induced polarization on droplet (EPD). EPD enables all-liquid actuation in principle and experimentally exhibits generality for actuating various inorganic/organic liquids with relative permittivity ranging from 2.25 to 84.2 and volume from 500 nL to 1 mL. Moreover, EPD is capable of actuating various biochemical samples without compromising their activities, including various body fluids, living cells, and proteins. A robotic system is also coupled with the EPD mechanism to enable full automation. EPD's high adaptability with liquid types and biochemical samples thus promotes the automation of liquid-based scientific experiments across multiple disciplines.
Collapse
Affiliation(s)
- Ruotong Zhang
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China
| | - Chengzhi Zhang
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China
- Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen, Guangdong, China
| | - Xiaoxue Fan
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China
| | - Christina C K Au Yeung
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China
- Advanced Biomedical Instrumentation Centre, Hong Kong Science Park, Hong Kong SAR, China
| | - Huiyanchen Li
- Advanced Biomedical Instrumentation Centre, Hong Kong Science Park, Hong Kong SAR, China
| | - Haisong Lin
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China.
- Advanced Biomedical Instrumentation Centre, Hong Kong Science Park, Hong Kong SAR, China.
| | - Ho Cheung Shum
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong SAR, China.
- Advanced Biomedical Instrumentation Centre, Hong Kong Science Park, Hong Kong SAR, China.
| |
Collapse
|
4
|
Urrutia Iturritza M, Mlotshwa P, Gantelius J, Alfvén T, Loh E, Karlsson J, Hadjineophytou C, Langer K, Mitsakakis K, Russom A, Jönsson HN, Gaudenzi G. An Automated Versatile Diagnostic Workflow for Infectious Disease Detection in Low-Resource Settings. MICROMACHINES 2024; 15:708. [PMID: 38930678 PMCID: PMC11205418 DOI: 10.3390/mi15060708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Revised: 05/21/2024] [Accepted: 05/22/2024] [Indexed: 06/28/2024]
Abstract
Laboratory automation effectively increases the throughput in sample analysis, reduces human errors in sample processing, as well as simplifies and accelerates the overall logistics. Automating diagnostic testing workflows in peripheral laboratories and also in near-patient settings -like hospitals, clinics and epidemic control checkpoints- is advantageous for the simultaneous processing of multiple samples to provide rapid results to patients, minimize the possibility of contamination or error during sample handling or transport, and increase efficiency. However, most automation platforms are expensive and are not easily adaptable to new protocols. Here, we address the need for a versatile, easy-to-use, rapid and reliable diagnostic testing workflow by combining open-source modular automation (Opentrons) and automation-compatible molecular biology protocols, easily adaptable to a workflow for infectious diseases diagnosis by detection on paper-based diagnostics. We demonstrated the feasibility of automation of the method with a low-cost Neisseria meningitidis diagnostic test that utilizes magnetic beads for pathogen DNA isolation, isothermal amplification, and detection on a paper-based microarray. In summary, we integrated open-source modular automation with adaptable molecular biology protocols, which was also faster and cheaper to perform in an automated than in a manual way. This enables a versatile diagnostic workflow for infectious diseases and we demonstrated this through a low-cost N. meningitidis test on paper-based microarrays.
Collapse
Affiliation(s)
- Miren Urrutia Iturritza
- Department of Global Public Health, Karolinska Institutet, 17177 Stockholm, Sweden; (M.U.I.); (P.M.); (J.G.); (T.A.)
- Science for Life Laboratory, Division of Nanobiotechnology, Department of Protein Science, KTH Royal Institute of Technology, 17165 Stockholm, Sweden; (K.L.); (A.R.); (H.N.J.)
| | - Phuthumani Mlotshwa
- Department of Global Public Health, Karolinska Institutet, 17177 Stockholm, Sweden; (M.U.I.); (P.M.); (J.G.); (T.A.)
| | - Jesper Gantelius
- Department of Global Public Health, Karolinska Institutet, 17177 Stockholm, Sweden; (M.U.I.); (P.M.); (J.G.); (T.A.)
- Science for Life Laboratory, Division of Nanobiotechnology, Department of Protein Science, KTH Royal Institute of Technology, 17165 Stockholm, Sweden; (K.L.); (A.R.); (H.N.J.)
| | - Tobias Alfvén
- Department of Global Public Health, Karolinska Institutet, 17177 Stockholm, Sweden; (M.U.I.); (P.M.); (J.G.); (T.A.)
| | - Edmund Loh
- Department of Microbiology, Tumor and Cell Biology, Karolinska Institutet, 17165 Stockholm, Sweden; (E.L.); (J.K.); (C.H.)
| | - Jens Karlsson
- Department of Microbiology, Tumor and Cell Biology, Karolinska Institutet, 17165 Stockholm, Sweden; (E.L.); (J.K.); (C.H.)
| | - Chris Hadjineophytou
- Department of Microbiology, Tumor and Cell Biology, Karolinska Institutet, 17165 Stockholm, Sweden; (E.L.); (J.K.); (C.H.)
| | - Krzysztof Langer
- Science for Life Laboratory, Division of Nanobiotechnology, Department of Protein Science, KTH Royal Institute of Technology, 17165 Stockholm, Sweden; (K.L.); (A.R.); (H.N.J.)
| | - Konstantinos Mitsakakis
- Hahn-Schickard, Georges-Koehler-Allee 103, 79110 Freiburg, Germany;
- Laboratory for MEMS Applications, IMTEK–Department of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 103, 79108 Freiburg, Germany
| | - Aman Russom
- Science for Life Laboratory, Division of Nanobiotechnology, Department of Protein Science, KTH Royal Institute of Technology, 17165 Stockholm, Sweden; (K.L.); (A.R.); (H.N.J.)
| | - Håkan N. Jönsson
- Science for Life Laboratory, Division of Nanobiotechnology, Department of Protein Science, KTH Royal Institute of Technology, 17165 Stockholm, Sweden; (K.L.); (A.R.); (H.N.J.)
| | - Giulia Gaudenzi
- Department of Global Public Health, Karolinska Institutet, 17177 Stockholm, Sweden; (M.U.I.); (P.M.); (J.G.); (T.A.)
- Science for Life Laboratory, Division of Nanobiotechnology, Department of Protein Science, KTH Royal Institute of Technology, 17165 Stockholm, Sweden; (K.L.); (A.R.); (H.N.J.)
| |
Collapse
|
5
|
Raju C, Elpa DP, Urban PL. Automation and Computerization of (Bio)sensing Systems. ACS Sens 2024; 9:1033-1048. [PMID: 38363106 PMCID: PMC10964247 DOI: 10.1021/acssensors.3c01887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 12/21/2023] [Accepted: 01/29/2024] [Indexed: 02/17/2024]
Abstract
Sensing systems necessitate automation to reduce human effort, increase reproducibility, and enable remote sensing. In this perspective, we highlight different types of sensing systems with elements of automation, which are based on flow injection and sequential injection analysis, microfluidics, robotics, and other prototypes addressing specific real-world problems. Finally, we discuss the role of computer technology in sensing systems. Automated flow injection and sequential injection techniques offer precise and efficient sample handling and dependable outcomes. They enable continuous analysis of numerous samples, boosting throughput, and saving time and resources. They enhance safety by minimizing contact with hazardous chemicals. Microfluidic systems are enhanced by automation to enable precise control of parameters and increase of analysis speed. Robotic sampling and sample preparation platforms excel in precise execution of intricate, repetitive tasks such as sample handling, dilution, and transfer. These platforms enhance efficiency by multitasking, use minimal sample volumes, and they seamlessly integrate with analytical instruments. Other sensor prototypes utilize mechanical devices and computer technology to address real-world issues, offering efficient, accurate, and economical real-time solutions for analyte identification and quantification in remote areas. Computer technology is crucial in modern sensing systems, enabling data acquisition, signal processing, real-time analysis, and data storage. Machine learning and artificial intelligence enhance predictions from the sensor data, supporting the Internet of Things with efficient data management.
Collapse
Affiliation(s)
- Chamarthi
Maheswar Raju
- Department of Chemistry, National
Tsing Hua University 101, Section 2, Kuang-Fu Rd., Hsinchu 300044, Taiwan
| | - Decibel P. Elpa
- Department of Chemistry, National
Tsing Hua University 101, Section 2, Kuang-Fu Rd., Hsinchu 300044, Taiwan
| | - Pawel L. Urban
- Department of Chemistry, National
Tsing Hua University 101, Section 2, Kuang-Fu Rd., Hsinchu 300044, Taiwan
| |
Collapse
|
6
|
Bai C, Tang X, Li Y, Arai T, Huang Q, Liu X. Acoustohydrodynamic micromixers: Basic mixing principles, programmable mixing prospectives, and biomedical applications. BIOMICROFLUIDICS 2024; 18:021505. [PMID: 38659428 PMCID: PMC11037935 DOI: 10.1063/5.0179750] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Accepted: 02/28/2024] [Indexed: 04/26/2024]
Abstract
Acoustohydrodynamic micromixers offer excellent mixing efficiency, cost-effectiveness, and flexible controllability compared with conventional micromixers. There are two mechanisms in acoustic micromixers: indirect influence by induced streamlines, exemplified by sharp-edge micromixers, and direct influence by acoustic waves, represented by surface acoustic wave micromixers. The former utilizes sharp-edge structures, while the latter employs acoustic wave action to affect both the fluid and its particles. However, traditional micromixers with acoustic bubbles achieve significant mixing performance and numerous programmable mixing platforms provide excellent solutions with wide applicability. This review offers a comprehensive overview of various micromixers, elucidates their underlying principles, and explores their biomedical applications. In addition, advanced programmable micromixing with impressive versatility, convenience, and ability of cross-scale operations is introduced in detail. We believe this review will benefit the researchers in the biomedical field to know the micromixers and find a suitable micromixing method for their various applications.
Collapse
Affiliation(s)
- Chenhao Bai
- The Key Laboratory of Biomimetic Robots and Systems, Ministry of Education, State Key Laboratory of Intelligent Control and Decision of Complex System, Beijing Advanced Innovation Center for Intelligent Robots and Systems, and School of Mechatronical Engineering, Beijing Institute of Technology, Beijing 100081, China
| | - Xiaoqing Tang
- The Key Laboratory of Biomimetic Robots and Systems, Ministry of Education, State Key Laboratory of Intelligent Control and Decision of Complex System, Beijing Advanced Innovation Center for Intelligent Robots and Systems, and School of Mechatronical Engineering, Beijing Institute of Technology, Beijing 100081, China
| | - Yuyang Li
- Institute of Intelligent Flexible Mechatronics, Jiangsu University, Zhenjiang 212013, China
| | - Tatsuo Arai
- The Key Laboratory of Biomimetic Robots and Systems, Ministry of Education, State Key Laboratory of Intelligent Control and Decision of Complex System, Beijing Advanced Innovation Center for Intelligent Robots and Systems, and School of Mechatronical Engineering, Beijing Institute of Technology, Beijing 100081, China
| | - Qiang Huang
- The Key Laboratory of Biomimetic Robots and Systems, Ministry of Education, State Key Laboratory of Intelligent Control and Decision of Complex System, Beijing Advanced Innovation Center for Intelligent Robots and Systems, and School of Mechatronical Engineering, Beijing Institute of Technology, Beijing 100081, China
| | - Xiaoming Liu
- The Key Laboratory of Biomimetic Robots and Systems, Ministry of Education, State Key Laboratory of Intelligent Control and Decision of Complex System, Beijing Advanced Innovation Center for Intelligent Robots and Systems, and School of Mechatronical Engineering, Beijing Institute of Technology, Beijing 100081, China
| |
Collapse
|
7
|
Khodadadi R, Pishbin E, Eghbal M, Abrinia K. Real-time monitoring and actuation of a hybrid siphon valve for hematocrit-independent plasma separation from whole blood. Analyst 2023; 148:5456-5468. [PMID: 37750420 DOI: 10.1039/d3an00862b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/27/2023]
Abstract
Centrifugal microfluidics have emerged as a pivotal area of research spanning multiple domains, including medicine and chemistry. Among passive valving strategies, siphon valves have gained prominence due to their inherent simplicity and self-reliance, eliminating the need for external equipment. However, achieving optimal valve performance mandates supplementary elements like surface adjustments or pneumatic pressure. These introduce intricacies such as time-dependent behavior and augmented spatial demands. This research introduces inventive design and manufacturing methodologies to amplify siphon valve functionality. Our proposed innovation situates the siphon microchannel on the external surface of the primary chamber, linked via an inlet. The crux of novelty lies in the adaptable material selection for the microchannel's upper or lower surfaces, allowing the integration of hydrophilic materials such as glass or super hydrophilic coverslips, ensuring a leakage-free operation. Our approach offers a streamlined concept and manufacturing process, ensures consistent time-independent functionality, and accommodates the integration of multiple siphon valves within a solitary chamber, tailored for specific applications. Experimental evaluations validate a robust alignment between acquired data and analytical outcomes based on a modified equation. A customized disc is engineered, featuring four siphon valves meticulously calibrated for hematocrit (HCT) levels spanning from 20% to 50% at 10% intervals. Harnessing these valves yields a substantial surge in plasma separation efficiency, scaling up to 75%. Notably, this performance eclipses traditional single-valve reliant microfluidic methodologies, achieving a purity level exceeding 99% in plasma separation. These findings underscore the auspicious practical applicability of our proposed technique in plasma separation, fostering heightened platelet concentration, and expediting blood sample analysis.
Collapse
Affiliation(s)
- Reza Khodadadi
- School of Mechanical Engineering, University of Tehran, Tehran, Iran
| | - Esmail Pishbin
- Bio-microfluidics Laboratory, Department of Electrical Engineering and Information Technology, Iranian Research Organization for Science and Technology, Tehran, Iran.
| | - Manouchehr Eghbal
- Bio-microfluidics Laboratory, Department of Electrical Engineering and Information Technology, Iranian Research Organization for Science and Technology, Tehran, Iran.
| | - Karen Abrinia
- School of Mechanical Engineering, University of Tehran, Tehran, Iran
| |
Collapse
|
8
|
Gao S, Rui X, Zeng X, Zhou J. EWOD Chip with Micro-Barrier Electrode for Simultaneous Enhanced Mixing during Transportation. SENSORS (BASEL, SWITZERLAND) 2023; 23:7102. [PMID: 37631640 PMCID: PMC10459807 DOI: 10.3390/s23167102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 08/03/2023] [Accepted: 08/10/2023] [Indexed: 08/27/2023]
Abstract
Digital microfluidic platforms have been extensively studied in biology. However, achieving efficient mixing of macromolecules in microscale, low Reynolds number fluids remains a major challenge. To address this challenge, this study presents a novel design solution based on dielectric electro-wetting (EWOD) by optimizing the geometry of the transport electrode. The new design integrates micro-barriers on the electrodes to generate vortex currents that promote mixing during droplet transport. This design solution requires only two activation signals, minimizing the number of pins required. The mixing performance of the new design was evaluated by analyzing the degree of mixing inside the droplet and quantifying the motion of the internal particles. In addition, the rapid mixing capability of the new platform was demonstrated by successfully mixing the sorbitol solution with the detection solution and detecting the resulting reaction products. The experimental results show that the transfer electrode with a micro-barrier enables rapid mixing of liquids with a six-fold increase in mixing efficiency, making it ideal for the development of EWOD devices.
Collapse
Affiliation(s)
- Shang Gao
- School of Microelectronics, Fudan University, Shanghai 200433, China; (S.G.); (X.R.)
| | - Xichuan Rui
- School of Microelectronics, Fudan University, Shanghai 200433, China; (S.G.); (X.R.)
- Department of Micro/Nano Electronics State Key Laboratory of Radio Frequency Heterogeneous Integration, Shanghai Jiao Tong University, Shanghai 200433, China
| | - Xiangyu Zeng
- School of Microelectronics, Fudan University, Shanghai 200433, China; (S.G.); (X.R.)
| | - Jia Zhou
- School of Microelectronics, Fudan University, Shanghai 200433, China; (S.G.); (X.R.)
| |
Collapse
|