1
|
Hu W, Ao H, Lv Z, Xiao W, Li W, Lei J, Wu J, Ju H. Glow-type luminol chemiluminescence based on a supramolecular enhancer of cyclodextrin. Anal Chim Acta 2024; 1328:343182. [PMID: 39266198 DOI: 10.1016/j.aca.2024.343182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2024] [Revised: 08/27/2024] [Accepted: 08/28/2024] [Indexed: 09/14/2024]
Abstract
BACKGROUND Chemiluminescence (CL) bioassay is one of the most advanced and used detection method in clinical diagnosis and biomedical research because of the advantages of low background, easy operation, and wide-field imaging without a light source or microscope. The luminol/hydrogen peroxide/horseradish peroxidase (luminol/H2O2/HRP) system is the most popular CL system, but its application in high-throughput imaging detection is challenged due to its low luminescence efficiency and flash-type emission which is difficult in ensuring the reproducibility and consistency of detection results. RESULTS We reported a glow-type CL system of luminol@CD/H2O2/HRP by using a supramolecular enhancer of cyclodextrin (CD). This luminol@CD/H2O2/HRP system exhibited a luminescence lifetime of 41 min for sensitive and accurate imaging analysis. The long-lasting CL emission was attributed to the formation of a 1:1 host-guest complex between luminol and CD, which could stabilize the emitter and effectively reduce nonradiative relaxation. The formation of luminol@CD complex was determined through NMR experiments and theoretical analysis. Under optimum conditions, the luminol@CD/H2O2/HRP system showed higher sensitivity and much better precision than classical luminol/H2O2/HRP system for imaging detection of HRP. Especially, this glow-type luminol@CD/H2O2/HRP system realized CL imaging of microwell arrays on microfluidic chips. In addition, the luminol@CD/H2O2/HRP system was successfully applied for point-of-care detection of 17β-estradiol based on a competitive mechanism of host-guest recognition. SIGNIFICANCE An efficient CL system is crucial for obtaining reproducible and consistent results for accurate detection. Our luminol@CD/H2O2/HRP system emitted strong and persistent luminescence, resulting in reliability and efficiency at both CL macroscopic and microscopic imaging detection. We expected the luminol@CD/H2O2/HRP CL system to be applied in various detection fields.
Collapse
Affiliation(s)
- Wenrui Hu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China
| | - Hang Ao
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China
| | - Ziyi Lv
- Key Laboratory of Mesoscopic Chemistry of Ministry of Education, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China
| | - Wencheng Xiao
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China
| | - Wei Li
- Key Laboratory of Mesoscopic Chemistry of Ministry of Education, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China
| | - Jianping Lei
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China
| | - Jie Wu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China.
| | - Huangxian Ju
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China
| |
Collapse
|
2
|
Huang D, Huang E, Cai D, Chen Z, Wen H, Wang Y, Ma D, Lu Y, Liu X, Liu D. Automated Droplet Ejection from a Digital Microfluidics Sample Pretreatment Device Enables Batch-Mode Chemiluminescence Immunoassay. Anal Chem 2024; 96:14433-14440. [PMID: 39103289 DOI: 10.1021/acs.analchem.4c02217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/07/2024]
Abstract
Digital microfluidics (DMF) features programmed manipulation of fluids in multiple steps, making it a valuable tool for sample pretreatment. However, the integration of sample pretreatment with its downstream reaction and detection requires transferring droplets from the DMF device to the outside world. To address this issue, the present study developed a modified DMF device that allows automated droplet ejection out of the chip, facilitated by a tailor-designed interface. A double-layered DMF microchip with an oil-filled medium was flipped over, with a liquid infusion port and a liquid expulsion port accommodated on the top working PCB plate and the bottom grounded ITO plate, respectively, to facilitate chip-to-world delivery of droplets. Using chemiluminescent immunoassay (CLIA) as an illustrative application, the sample pretreatment was programmed on the DMF device, and CLIA droplets were ejected from the chip for signal reading. In our workflow, CLIA droplets can be ejected from the DMF device through the chip-to-world interface, freeing up otherwise occupied electrodes for more sample pretreatment and enabling streamlined droplet microreactions and batch-mode operation for bioanalysis. Integrated with these interfacing portals, the DMF system achieved a single-channel throughput of 17 samples per hour, which can be further upscaled for more productive applications by parallelizing the DMF modules. The results of this study demonstrate that the droplet ejection function that is innovated in a DMF sample pretreatment microsystem can significantly improve analytical throughput, providing an approach to establishing an automated but decentralized biochemical sample preparation workstation for large-scale and continuous bioanalysis.
Collapse
Affiliation(s)
- Dezhi Huang
- Department of Laboratory Medicine, The Second Affiliated Hospital, School of Medicine, South China University of Technology, Guangzhou 510180, China
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen 518116, China
| | - Enqi Huang
- Department of Laboratory Medicine, The Second Affiliated Hospital, School of Medicine, South China University of Technology, Guangzhou 510180, China
| | - Dongyang Cai
- Department of Laboratory Medicine, The Second Affiliated Hospital, School of Medicine, South China University of Technology, Guangzhou 510180, China
- Guangdong Engineering Technology Research Center of Microfluidic Chip Medical Diagnosis, Guangzhou 510180, China
| | - Zhenhua Chen
- Department of Laboratory Medicine, The Second Affiliated Hospital, School of Medicine, South China University of Technology, Guangzhou 510180, China
- Guangdong Engineering Technology Research Center of Microfluidic Chip Medical Diagnosis, Guangzhou 510180, China
| | - Hongting Wen
- Department of Laboratory Medicine, The Second Affiliated Hospital, School of Medicine, South China University of Technology, Guangzhou 510180, China
| | - Yu Wang
- Department of Laboratory Medicine, The Second Affiliated Hospital, School of Medicine, South China University of Technology, Guangzhou 510180, China
- Bioland Laboratory (Guangzhou Regenerative Medicine and Health Guangdong Laboratory), Guangzhou 510005, China
| | - Dachuan Ma
- Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, Liaoning, China
| | - Yao Lu
- Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, Liaoning, China
| | - Xianming Liu
- Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, Liaoning, China
| | - Dayu Liu
- Department of Laboratory Medicine, The Second Affiliated Hospital, School of Medicine, South China University of Technology, Guangzhou 510180, China
- Guangdong Engineering Technology Research Center of Microfluidic Chip Medical Diagnosis, Guangzhou 510180, China
| |
Collapse
|
3
|
Tong W, Shi J, Yu Z, Ran B, Chen H, Zhu Y. High sensitivity and automatic chemiluminescence detection of glucose and lactate using a spin-disc paper-based device. LAB ON A CHIP 2024; 24:810-818. [PMID: 38224458 DOI: 10.1039/d3lc00937h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/16/2024]
Abstract
This paper reports a spin-disc paper-based device with 10 individual detection units containing electromagnetic modules controlling the sample incubation time before chemiluminescence (CL) signal detection. After the sample was added to the top paper chip and incubated with the enzyme, the electromagnet was turned off to allow contact between the top and bottom paper. The H2O2 generated by the sample flowed vertically to the bottom paper and initiated the oxidase of the luminol to generate the CL signal. After one detection the disc was automatically rotated to the next position to repeat the above detection. The advantage of using the device over the lateral flow and the in situ detection was firstly proved using the detection of H2O2 and the glucose/lactate sample with 5 minute incubation. The CL intensity was increased 300 times/1000 times as the glucose/lactate was incubated for 5 minutes compared to the non-incubated samples. Afterward, the device was employed to separately detect glucose and lactate diluted in PBS, artificial sweat, artificial saliva, and fresh cell culture media. Finally, the device was employed to detect the glucose and lactate in the media collected over the 24 hour culture of PC3 cells. The uptake and production rates of glucose and lactate were correspondingly determined as 0.328 ± 0.015 pmol h-1 per cell and 1.254 ± 0.053 pmol h-1 per cell, respectively. The reported device has wide application potential due to its capabilities in automatic detection of multiple samples with very high sensitivity and small sample volume (down to 0.5 μL).
Collapse
Affiliation(s)
- Wenqiang Tong
- School of Science, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China
- Center for Microflows and Nanoflows, School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China
| | - Jiaming Shi
- School of Science, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China
- Center for Microflows and Nanoflows, School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China
| | - Zhihang Yu
- School of Science, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China
- Center for Microflows and Nanoflows, School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China
| | - Bin Ran
- School of Science, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China
- Center for Microflows and Nanoflows, School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China
| | - Huaying Chen
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China.
- Center for Microflows and Nanoflows, School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China
| | - Yonggang Zhu
- School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China.
- Center for Microflows and Nanoflows, School of Mechanical Engineering and Automation, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China
| |
Collapse
|