1
|
Kaium MG, Han SS, Lee CW, Jung Y. Calcium Alginate as an Active Device Component for Light-Triggered Degradation of 2D MoS 2-Based Transient Electronics. ACS APPLIED MATERIALS & INTERFACES 2024; 16:39673-39682. [PMID: 39022803 DOI: 10.1021/acsami.4c09275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/20/2024]
Abstract
Transient electronics technology has enabled the programmed disintegration of functional devices, paving the way for environmentally sustainable management of electronic wastes as well as facilitating the exploration of novel device concepts. While a variety of inorganic and/or organic materials have been employed as media to introduce transient characteristics in electronic devices, they have been mainly limited to function as passive device components. Herein, we report that calcium (Ca) alginate, a natural biopolymer, exhibits multifunctionalities of introducing light-triggered transient characteristics as well as constituting active components in electronic devices integrated with two-dimensional (2D) molybdenum disulfide (MoS2) layers. Ca2+ ions-based alginate electrolyte films are prepared through hydrolysis reactions and are subsequently incorporated with riboflavin, a natural photosensitizer, for the light-driven dissolution of 2D MoS2 layers. The alginate films exhibit strain-sensitive triboelectricity, confirming the presence of abundant mobile Ca2+ ions, which enables them to be active components of 2D MoS2 field-effect transistors (FETs) functioning as electrolyte top-gates. The alginate-integrated 2D MoS2 FETs display intriguing transient characteristics of spontaneous degradation upon ultraviolet-to-visible light illumination as well as water exposure. Such transient characteristics are demonstrated even in ambient conditions with natural sunlight, highlighting the versatility of the developed approach. This study emphasizes a relatively unexplored aspect of combining naturally abundant polymers with emerging near atom-thickness semiconductors toward realizing unconventional and transformative device functionalities.
Collapse
Affiliation(s)
- Md Golam Kaium
- Department of Materials Science and Engineering, University of Central Florida, Orlando, Florida 32816, United States
| | - Sang Sub Han
- NanoScience Technology Center, University of Central Florida, Orlando, Florida 32826, United States
| | - Chung Won Lee
- NanoScience Technology Center, University of Central Florida, Orlando, Florida 32826, United States
| | - Yeonwoong Jung
- Department of Materials Science and Engineering, University of Central Florida, Orlando, Florida 32816, United States
- NanoScience Technology Center, University of Central Florida, Orlando, Florida 32826, United States
- Department of Electrical and Computer Engineering, University of Central Florida, Orlando, Florida 32816, United States
| |
Collapse
|
2
|
Pisal Deshmukh A, Patil K, Barve K, Bhave T. Transient N-GQDs/PVA nanocomposite thin film for memristor application. NANOTECHNOLOGY 2024; 35:265706. [PMID: 38513286 DOI: 10.1088/1361-6528/ad364b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Accepted: 03/21/2024] [Indexed: 03/23/2024]
Abstract
In recent years quantum dot (QDs) based resistive switching devices(memristors) have gained a lot of attention. Here we report the resistive switching behavior of nitrogen-doped graphene quantum dots/Polyvinyl alcohol (N-GQDs/PVA) degradable nanocomposite thin film with different weight percentages (wt.%) of N-GQDs. The memristor device was fabricated by a simple spin coating technique. It was found that 1 wt% N-GQDs/PVA device shows a prominent resistive switching phenomenon with good cyclic stability, high on/off ratio of ~102and retention time of ∼104s. From a detailed experimental study of band structure, we conclude that memristive behavior originates from the space charge controlled conduction (SCLC) mechanism. Further transient property of built memristive device was studied. Within three minutes of being submerged in distilled water, the fabricated memory device was destroyed. This phenomenon facilitates the usage of fabricated memristor devices to develop memory devices for military and security purposes.
Collapse
Affiliation(s)
- Akshaya Pisal Deshmukh
- Department of Applied Physics, Defence Institute of Advanced Technology, Deemed University, Girinagar, Pune, 411025, India
| | - Kalyanee Patil
- Department of Applied Physics, Defence Institute of Advanced Technology, Deemed University, Girinagar, Pune, 411025, India
| | - Kanchan Barve
- Department of Physics and Centre for Energy Science, Indian Institute of Science Education and Research, Pune, Dr Homi Bhabha Road, Pune, 411008, India
| | - Tejashree Bhave
- Department of Applied Physics, Defence Institute of Advanced Technology, Deemed University, Girinagar, Pune, 411025, India
| |
Collapse
|
3
|
Dutta A, Niu Z, Abdullah AM, Tiwari N, Biswas MAS, Li B, Lorestani F, Jing Y, Cheng H, Zhang S. Closely Packed Stretchable Ultrasound Array Fabricated with Surface Charge Engineering for Contactless Gesture and Materials Detection. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2303403. [PMID: 38348559 PMCID: PMC11022739 DOI: 10.1002/advs.202303403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 01/14/2024] [Indexed: 03/20/2024]
Abstract
Communication with hand gestures plays a significant role in human-computer interaction by providing an intuitive and natural way for humans to communicate with machines. Ultrasound-based devices have shown promising results in contactless hand gesture recognition without requiring physical contact. However, it is challenging to fabricate a densely packed wearable ultrasound array. Here, a stretchable ultrasound array is demonstrated with closely packed transducer elements fabricated using surface charge engineering between pre-charged 1-3 Lead Zirconate Titanate (PZT) composite and thin polyimide film without using a microscope. The array exhibits excellent ultrasound properties with a wide bandwidth (≈57.1%) and high electromechanical coefficient (≈0.75). The ultrasound array can decipher gestures up to 10 cm in distance by using a contactless triboelectric module and identify materials from the time constant of the exponentially decaying impedance based on their triboelectric properties by utilizing the electrostatic induction phase. The newly proposed metric of the areal-time constant is material-specific and decreases monotonically from a highly positive human body (1.13 m2 s) to negatively charged polydimethylsiloxane (PDMS) (0.02 m2 s) in the triboelectric series. The capability of the closely packed ultrasound array to detect material along with hand gesture interpretation provides an additional dimension in the next-generation human-robot interaction.
Collapse
Affiliation(s)
- Ankan Dutta
- Department of Engineering Science and MechanicsThe Pennsylvania State UniversityUniversity ParkState CollegePA16802USA
- Center for Neural EngineeringThe Pennsylvania State UniversityUniversity ParkState CollegePA16802USA
| | - Zhenyuan Niu
- Department of Engineering Science and MechanicsThe Pennsylvania State UniversityUniversity ParkState CollegePA16802USA
| | - Abu Musa Abdullah
- Department of Engineering Science and MechanicsThe Pennsylvania State UniversityUniversity ParkState CollegePA16802USA
| | - Naveen Tiwari
- Department of Engineering Science and MechanicsThe Pennsylvania State UniversityUniversity ParkState CollegePA16802USA
- Center for Research in Biological Chemistry and Molecular Materials (CiQUS)University of Santiago de CompostelaSantiago de Compostela15705Spain
| | - Md Abu Sayeed Biswas
- Department of Engineering Science and MechanicsThe Pennsylvania State UniversityUniversity ParkState CollegePA16802USA
| | - Bowen Li
- Department of Engineering Science and MechanicsThe Pennsylvania State UniversityUniversity ParkState CollegePA16802USA
| | - Farnaz Lorestani
- Department of Engineering Science and MechanicsThe Pennsylvania State UniversityUniversity ParkState CollegePA16802USA
| | - Yun Jing
- Graduate Program in AcousticsThe Pennsylvania State UniversityUniversity ParkState CollegePA16802USA
| | - Huanyu Cheng
- Department of Engineering Science and MechanicsThe Pennsylvania State UniversityUniversity ParkState CollegePA16802USA
| | - Senhao Zhang
- Suzhou Institute of Biomedical Engineering and TechnologyUniversity of Science and Technology of ChinaSchool of Biomedical Engineering165085, 88 Keling Rd, Huqiu DistrictSuzhouJiangsu215163China
| |
Collapse
|
4
|
Bhatia A, Hanna J, Stuart T, Kasper KA, Clausen DM, Gutruf P. Wireless Battery-free and Fully Implantable Organ Interfaces. Chem Rev 2024; 124:2205-2280. [PMID: 38382030 DOI: 10.1021/acs.chemrev.3c00425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Abstract
Advances in soft materials, miniaturized electronics, sensors, stimulators, radios, and battery-free power supplies are resulting in a new generation of fully implantable organ interfaces that leverage volumetric reduction and soft mechanics by eliminating electrochemical power storage. This device class offers the ability to provide high-fidelity readouts of physiological processes, enables stimulation, and allows control over organs to realize new therapeutic and diagnostic paradigms. Driven by seamless integration with connected infrastructure, these devices enable personalized digital medicine. Key to advances are carefully designed material, electrophysical, electrochemical, and electromagnetic systems that form implantables with mechanical properties closely matched to the target organ to deliver functionality that supports high-fidelity sensors and stimulators. The elimination of electrochemical power supplies enables control over device operation, anywhere from acute, to lifetimes matching the target subject with physical dimensions that supports imperceptible operation. This review provides a comprehensive overview of the basic building blocks of battery-free organ interfaces and related topics such as implantation, delivery, sterilization, and user acceptance. State of the art examples categorized by organ system and an outlook of interconnection and advanced strategies for computation leveraging the consistent power influx to elevate functionality of this device class over current battery-powered strategies is highlighted.
Collapse
Affiliation(s)
- Aman Bhatia
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Jessica Hanna
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Tucker Stuart
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Kevin Albert Kasper
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - David Marshall Clausen
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Philipp Gutruf
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
- Department of Electrical and Computer Engineering, The University of Arizona, Tucson, Arizona 85721, United States
- Bio5 Institute, The University of Arizona, Tucson, Arizona 85721, United States
- Neuroscience Graduate Interdisciplinary Program (GIDP), The University of Arizona, Tucson, Arizona 85721, United States
| |
Collapse
|
5
|
Bo R, Xu S, Yang Y, Zhang Y. Mechanically-Guided 3D Assembly for Architected Flexible Electronics. Chem Rev 2023; 123:11137-11189. [PMID: 37676059 PMCID: PMC10540141 DOI: 10.1021/acs.chemrev.3c00335] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Indexed: 09/08/2023]
Abstract
Architected flexible electronic devices with rationally designed 3D geometries have found essential applications in biology, medicine, therapeutics, sensing/imaging, energy, robotics, and daily healthcare. Mechanically-guided 3D assembly methods, exploiting mechanics principles of materials and structures to transform planar electronic devices fabricated using mature semiconductor techniques into 3D architected ones, are promising routes to such architected flexible electronic devices. Here, we comprehensively review mechanically-guided 3D assembly methods for architected flexible electronics. Mainstream methods of mechanically-guided 3D assembly are classified and discussed on the basis of their fundamental deformation modes (i.e., rolling, folding, curving, and buckling). Diverse 3D interconnects and device forms are then summarized, which correspond to the two key components of an architected flexible electronic device. Afterward, structure-induced functionalities are highlighted to provide guidelines for function-driven structural designs of flexible electronics, followed by a collective summary of their resulting applications. Finally, conclusions and outlooks are given, covering routes to achieve extreme deformations and dimensions, inverse design methods, and encapsulation strategies of architected 3D flexible electronics, as well as perspectives on future applications.
Collapse
Affiliation(s)
- Renheng Bo
- Applied
Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, 100084 Beijing, People’s Republic of China
- Laboratory
of Flexible Electronics Technology, Tsinghua
University, 100084 Beijing, People’s Republic
of China
| | - Shiwei Xu
- Applied
Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, 100084 Beijing, People’s Republic of China
- Laboratory
of Flexible Electronics Technology, Tsinghua
University, 100084 Beijing, People’s Republic
of China
| | - Youzhou Yang
- Applied
Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, 100084 Beijing, People’s Republic of China
- Laboratory
of Flexible Electronics Technology, Tsinghua
University, 100084 Beijing, People’s Republic
of China
| | - Yihui Zhang
- Applied
Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, 100084 Beijing, People’s Republic of China
- Laboratory
of Flexible Electronics Technology, Tsinghua
University, 100084 Beijing, People’s Republic
of China
| |
Collapse
|