1
|
Hofstra J, Budde IK, van Twuyver E, Choi G, Levi M, Leebeek F, de Monchy J, Ypma P, Keizer R, Huitema A, Strengers P. Treatment of hereditary angioedema with nanofiltered C1-esterase inhibitor concentrate (Cetor®): Multi-center phase II and III studies to assess pharmacokinetics, clinical efficacy and safety. Clin Immunol 2012; 142:280-90. [DOI: 10.1016/j.clim.2011.11.005] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2011] [Revised: 11/03/2011] [Accepted: 11/04/2011] [Indexed: 11/29/2022]
|
2
|
MAUSER-BUNSCHOTEN EP, KLEINE BUDDE I, LOPACIUK S, KOOPMAN MMW, Van Der MEER FJM, NOVÀKOVÀ IRO, YPMA P, Van Der LINDEN PWG, WINDYGA J, STRENGERS PFW. An ultrapure plasma-derived monoclonal antibody-purified factor IX concentrate (Nonafact®), results of phase III and IV clinical studies. Haemophilia 2011; 17:439-45. [DOI: 10.1111/j.1365-2516.2010.02453.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
3
|
DIEZ JM, CABALLERO S, BELDA FJ, OTEGUI M, GAJARDO R, JORQUERA JI. Elimination capacity of a TSE-model agent in the manufacturing process of Alphanate®/Fanhdi®, a human factor VIII/VWF complex concentrate. Haemophilia 2009; 15:1249-57. [DOI: 10.1111/j.1365-2516.2009.02067.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
4
|
Horowitz B, Busch M. Estimating the pathogen safety of manufactured human plasma products: application to fibrin sealants and to thrombin. Transfusion 2008; 48:1739-53. [PMID: 18466171 PMCID: PMC7201864 DOI: 10.1111/j.1537-2995.2008.01717.x] [Citation(s) in RCA: 71] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2007] [Revised: 01/24/2008] [Accepted: 01/27/2008] [Indexed: 12/21/2022]
Abstract
BACKGROUND Plasma fractionators have implemented many improvements over the past decade directed toward reducing the likelihood of pathogen transmission by purified blood products, yet little has been published attempting to assess the overall impact of these improvements on the probability of safety of the final product. STUDY DESIGN AND METHODS Safety margins for human immunodeficiency virus (HIV), hepatitis C virus (HCV), hepatitis B virus (HBV), hepatitis A virus (HAV), parvovirus B19, and variant form of Creutzfeldt-Jakob disease (vCJD) were calculated for the two fibrin sealants licensed in the United States and for thrombin. These products were selected because their use in a clinical setting is, in most cases, optional, and both were relatively recently approved for marketing by the US Food and Drug Administration (FDA). Moreover, thrombin and fibrinogen both undergo two dedicated virus inactivation steps and/or removal steps in accord with the recommendations of regulatory agencies worldwide. Safety margins were determined by comparing the potential maximum viral loads in contaminated units to viral clearance factors, ultimately leading to the calculation of the residual risk per vial. RESULTS The residual risk of pathogen transmission per vial was calculated to be less than 1 in 10(-15) for HIV, HCV, HBV, and HAV for both fibrinogen and thrombin. Owing to the greater quantities that can be present and its greater thermal stability, the calculated risk for parvovirus transmission was 1 in 500,000 vials for fibrinogen and less than 1 in 10(7) per vial for thrombin. Assuming that vCJD is found to be present in plasma donations, its risk of transmission by these purified and processed plasma derivatives would appear to be very low. CONCLUSIONS The pathogen safety initiatives implemented by plasma fractionators over the past 10 to 20 years have resulted in products with excellent pathogen safety profiles. Of the agents examined, parvovirus continues to have the lowest calculated margin of safety. Despite this, parvovirus transmissions should be rare. Manufacturers are encouraged to continue exploring processes to further enlarge parvovirus safety margins and to continue exploring ways of eliminating prions.
Collapse
|
5
|
Booth J, Vicik S, Tannatt M, Gallo C, Kelley B. Transmissible spongiform encephalopathy agent clearance by the immunoaffinity and anion-exchange chromatography steps of the ReFacto manufacturing process. Haemophilia 2007; 13:580-7. [PMID: 17880447 DOI: 10.1111/j.1365-2516.2007.01441.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
ReFacto (moroctocog alfa), a recombinant factor VIII approved for the treatment of haemophilia A, is produced by a mammalian cell-culture process that includes therapeutic-grade human serum albumin (HSA) in the cell-culture medium. While to date there have been no cases of transmissible spongiform encephalopathy (TSE) resulting from the clinical use of HSA, Wyeth conducted a study to demonstrate that the ReFacto manufacturing process has significant capacity to remove a TSE agent if it were present as a contaminant in the HSA. The immunoaffinity (8A4 Sepharose) and anion-exchange (Q Sepharose) chromatography steps were evaluated for the clearance of the hamster TSE agent, strain 263K. This Good Laboratory Practice study was performed using appropriately qualified, laboratory-scale chromatography systems. Filtered brain homogenate from TSE-infected hamsters was added to loads of both chromatographic columns, and the concentration of TSE agent in the loads and product pools were determined using a validated western blot quantitation method. Replicate chromatography runs were consistent, as demonstrated by the < or =0.7 log(10) difference observed in TSE agent reduction between each pair of runs. The immunoaffinity and anion-exchanges steps demonstrated 3.8 log reduction and >5.2 log reduction respectively. These data provide a high degree of assurance that in the unlikely event of a TSE contamination of the HSA used in the ReFacto cell-culture process, the purification steps have the potential to remove the infectious agent to extremely low levels, thereby significantly reducing the risk to patients receiving ReFacto.
Collapse
Affiliation(s)
- J Booth
- Purification Process Development, Wyeth Biotech, 1 Burtt Road, Andover, MA 01810, USA.
| | | | | | | | | |
Collapse
|
6
|
Mauser-Bunschoten EP, Posthouwer D, Fischer K, van den Berg HM. Safety and efficacy of a plasma-derived monoclonal purified factor VIII concentrate during 10 years of follow-up. Haemophilia 2007; 13:697-700. [PMID: 17877729 DOI: 10.1111/j.1365-2516.2007.01554.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
In 1995, AAFACT, a new monoclonal purified factor VIII concentrate (FVIII), derived from human plasma, was introduced in the Netherlands. The monoclonal purification based production process includes a viral inactivation step by solvent/detergent treatment. Products manufactured according to this procedure, for example Hemofil M are used worldwide. The aim of the present study was to assess inhibitor development in a large cohort of previously treated patients (PTPs) who were followed up for 10 years. In addition, efficacy, HIV and hepatitis C virus (HCV) transmission, and allergic reactions were monitored. All 165 patients with severe haemophilia A (FVIII<1%) known at the van Creveldkliniek who ever used AAFACT during the period from October 1995 to September 2005 were included. Two of them were previously untreated patients (PUPs) and two others had <50 exposure days. Data on FVIII consumption, number of exposures, bleedings and hospitalization days were collected from start of AAFACT until last clinical and laboratory evaluation while on this product. At the end of follow-up, 91 patients were still using this plasma-derived FVIII. Median age at start of follow-up was 26 years (range 1-52). None of the patients reported lack of efficacy. Median FVIII consumption per patient during follow-up was 2058 IU kg(-1) bodyweight per year, and median number of exposures was 148 per year. During 1029 patient-years of follow-up, one inhibitor was diagnosed in a previously treated patient PTP. This patient developed high titre inhibitor following surgery for which he, during 1 week, had been treated with continuous infusion with recombinant FVIII. No inhibitor occurred during 68 cases of surgery using continuous infusion with AAFACT. No viral transmissions or other adverse events occurred during 10 years of follow-up; AAFACT appeared to be an effective and safe FVIII product.
Collapse
Affiliation(s)
- E P Mauser-Bunschoten
- Van Creveldkliniek, Division of Internal Medicine, University Medical Centre Utrecht, Utrecht, The Netherlands.
| | | | | | | |
Collapse
|
7
|
Flan B, Arrabal S. Manufacture of plasma-derived products in France and measures to prevent the risk of vCJD transmission: Precautionary measures and efficacy of manufacturing processes in prion removal. Transfus Clin Biol 2007; 14:51-62. [PMID: 17540602 DOI: 10.1016/j.tracli.2007.04.008] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The emergence of the variant Creutzfeldt-Jakob disease in the mid 1990s soon raised concerns about its possible transmission through the use of blood and plasma-derived medicinal products. A risk analysis approach was initiated by health authorities, based on updated scientific knowledge and precautionary measures were implemented in France and other countries for the management of this new possible risk. Assessment of the vCJD risk is based on epidemiology and estimates of the number of potential cases in the future, on blood infectivity data from models of transmissible spongiform encephalopathies and on data from studies of the capacity of manufacturing processes to remove the agent, should it be present in the plasma of infected donors. The transmission of vCJD by non leukocyte-depleted labile blood components has recently been confirmed. There have been no reports of cases associated with the use of plasma-derived products and the scientific data, and risk analyses for those plasma products, which are of the greatest therapeutic interest, support their safety with respect to this transmission risk. The precautionary measures applied in France and the data contributing to the risk assessment of plasma products are reviewed and updated in the present paper. The uncertainties, which remain, are also addressed and discussed, as well as the ongoing research and developments in this area.
Collapse
Affiliation(s)
- Benoît Flan
- LFB S.A., 3 avenue des Tropiques, B.P. 305 Les Ulis, 91958 Courtaboeuf cedex, France.
| | | |
Collapse
|
8
|
Meeks SL, Josephson CD. Should hemophilia treaters switch to albumin-free recombinant factor VIII concentrates. Curr Opin Hematol 2006; 13:457-61. [PMID: 17053459 DOI: 10.1097/01.moh.0000245686.01591.f0] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE OF REVIEW To discuss the advantages and disadvantages of the albumin-free recombinant factor VIII concentrates in the treatment of hemophilia A. RECENT FINDINGS The third-generation recombinant factor VIII product Advate has been found to be safe and effective in treating bleeding associated with hemophilia A. SUMMARY Multiple issues must be considered when selecting a factor VIII concentrate for patients with hemophilia A including efficacy, availability, risk of transmission of infectious agents, risk of inhibitor development and cost. Third-generation recombinant factor VIII concentrates have been shown to be safe and effective. A theoretical improvement in risk of infectious agent transmission has been achieved by production of the products without human or animal plasma proteins. Controversy exists, however, with regard to a higher risk of inhibitor development with recombinant products. The higher cost of Advate can also potentially play a role in product choice. Overall every patient and their family must be presented with the advantages and disadvantages of all factor VIII concentrates, and be allowed to make an informed decision about which product to use for treatment.
Collapse
Affiliation(s)
- Shannon L Meeks
- Aflac Cancer Center and Blood Disorders Service, Emory University/Children's Healthcare of Atlanta, USA.
| | | |
Collapse
|
9
|
Balen AH, Lumholtz IB. Consensus statement on the bio-safety of urinary-derived gonadotrophins with respect to Creutzfeldt–Jakob disease. Hum Reprod 2005; 20:2994-9. [PMID: 16055457 DOI: 10.1093/humrep/dei209] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Human transmissible spongiform encephalopathies (TSE) encompass a group of rare neurodegenerative diseases. In April 2004, a group of international experts and regulators met in Buenos Aires, Argentina, to review the safety and to reach consensus on the use of urinary-derived gonadotrophins with respect to TSE. Iatrogenic transmission of Creutzfeldt-Jakob Disease (CJD) from pituitary-derived gonadotrophins has been reported, no infectivity in urine has been demonstrated, and no definite cases of transmission via urine have been reported. It is currently not possible to monitor donor urine or finished product for the presence of prions. Therefore the assessment of risk has to be based on the likelihood of infection in urine, the source of the urine, and the capacity of the manufacturing process to remove any adventitious infection. Urine for the production of medicinal products should be obtained from sources that minimize the possible presence of materials derived from subjects suffering from human TSE. As no strong evidence for TSE infectivity in urine exists, it can be concluded that the risk of disease-generating prions and TSE infectivity being present in donor urine is low. Current evidence indicates that, with respect to the risk of TSE infection, urinary-derived gonadotrophins appear to be safe.
Collapse
|
10
|
Foster PR, Griffin BD, Bienek C, McIntosh RV, MacGregor IR, Somerville RA, Steele PJ, Reichl HE. Distribution of a bovine spongiform encephalopathy-derived agent over ion-exchange chromatography used in the preparation of concentrates of fibrinogen and factor VIII. Vox Sang 2004; 86:92-9. [PMID: 15023177 DOI: 10.1111/j.0042-9007.2004.00403.x] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND AND OBJECTIVES The risk of haemophiliacs contracting variant Creutzfeldt-Jakob disease (vCJD) via treatment with factor VIII concentrates is not known. Therefore, in order to determine the extent to which the vCJD agent might be removed during the preparation of factor VIII concentrate, the partitioning of a bovine spongiform encephalopathy (BSE)-derived agent was measured over the main purification step used to prepare the Scottish National Blood Transfusion Service high-purity factor VIII concentrate (Liberate). MATERIALS AND METHODS Murine-passaged BSE (strain 301V), in the form of a microsomal fraction prepared from infected brain, was used to 'spike' a solution of factor VIII of intermediate purity. The 'spiked' starting material was subjected to solvent-detergent treatment and then to anion-exchange chromatography with Toyopearl DEAE-650M. All fractions were tested for 301V infectivity using a murine bioassay, including the procedures used to clean the ion-exchange media after use. RESULTS BSE 301V infectivity was reduced by 2.9 log(10) in the fibrinogen fraction and by 2.7 log(10) in the factor VIII fraction. Over 99% of the added 301V infectivity remained bound to the ion-exchange column after elution of factor VIII. A large quantity of infectivity was subsequently removed by washing the ion-exchange media with 2 m NaCl. No further BSE 301V infectivity was detected in column eluates after treatment with 0.1 m NaOH or a second wash with 2 m NaCl. CONCLUSIONS Results using a BSE-derived agent suggest that vCJD infectivity would be substantially removed by the ion-exchange process used in the preparation of fibrinogen and factor VIII concentrate. Although 301V infectivity remained bound to the ion-exchange matrix following elution of factor VIII, this appeared to be eliminated by the procedure used for cleaning the ion-exchange media after each use.
Collapse
Affiliation(s)
- P R Foster
- Scottish National Blood Transfusion Service, Edinburgh, UK.
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Brown P, Cervenakova L. The modern landscape of transfusion-related iatrogenic Creutzfeldt–Jakob disease and blood screening tests. Curr Opin Hematol 2004; 11:351-6. [PMID: 15666660 DOI: 10.1097/01.moh.0000143393.49202.f0] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
The idea that blood in naturally occurring transmissible spongiform encephalopathies is not infectious has imploded in the face of recent transmissions from the blood of naturally occurring scrapie in sheep and of variant Creutzfeldt-Jakob disease in humans. Although donor exclusion criteria ensure that the number of any further iatrogenic cases will be small, the risk of future blood-borne disease transmissions could be entirely eliminated by a diagnostic preclinical screening test. A variety of methodological approaches to blood testing are under development, with different levels of success, but no method has yet achieved the critical goal of discriminating transmissible spongiform encephalopathy-infected from healthy uninfected humans.
Collapse
Affiliation(s)
- Paul Brown
- National Institutes of Health, Bethesda, Maryland, USA.
| | | |
Collapse
|
12
|
Cervenakova L, Yakovleva O, McKenzie C, Kolchinsky S, McShane L, Drohan WN, Brown P. Similar levels of infectivity in the blood of mice infected with human-derived vCJD and GSS strains of transmissible spongiform encephalopathy. Transfusion 2004; 43:1687-94. [PMID: 14641865 DOI: 10.1046/j.0041-1132.2003.00586.x] [Citation(s) in RCA: 130] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND The possible transmission of variant CJD (vCJD) through blood transfusion or use of plasma-derived products prompted this study comparing infectivity in murine models of vCJD and Gerstmann-Sträussler-Scheinker (GSS) disease, a non-vCJD form of transmissible spongiform encephalopathy (TSE). STUDY DESIGN AND METHODS RIII/Fa/Dk (RIII) or Swiss-Webster (Swiss) mice were inoculated intracerebrally (IC) with mouse-adapted strains of vCJD or GSS (Fukuoka-1) of similar infectivity. Groups of RIII mice were euthanized 17 weeks after inoculation (during the incubation period), and another 23 weeks after inoculation (when symptomatic). Blood was collected, separated into components, and inoculated into groups of healthy mice; brains and spleens from all mice were harvested and tested for the presence of PrPres by Western blot using 6H4 MoAb. RESULTS Levels of 20-30 infectious doses per mL were present in buffy coat and plasma during both the incubation and symptomatic stages of disease; PLT pellet infectivity was lower (10 ID/mL) and RBCs were not infectious. The disease was transmitted more efficiently by IV than IC inoculation of plasma, but there was no difference observed with inoculation of buffy coat. The incubation period was shorter after IC inoculation of GSS- than vCJD-brain inocula. The amount of PrPres in spleens was similar for both TSE agents, but was slightly lower in brains of vCJD than GSS mice. CONCLUSION Infectivity was detected in blood components of mice infected with a human-derived strain of vCJD during both the preclinical and clinical phases of disease in a similarly low range of concentrations as in mice infected with a human-derived nonvariant strain (GSS, Fukuoka-1). Other measures of virulence, including brain infectivity titers, incubation periods, and the accumulation of PrPres in spleens and brains, were also comparable in both experimental models.
Collapse
Affiliation(s)
- Larisa Cervenakova
- Jerome H Holland Laboratory for the Biomedical Sciences, Red Cross, Rockville, MD 20855, USA.
| | | | | | | | | | | | | |
Collapse
|
13
|
|
14
|
Armstrong RA, Cairns NJ, Ironside JW, Lantos PL. Does the neuropathology of human patients with variant Creutzfeldt-Jakob disease reflect haematogenous spread of the disease? Neurosci Lett 2003; 348:37-40. [PMID: 12893420 DOI: 10.1016/s0304-3940(03)00696-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
To test the hypothesis that the distribution of the pathology in variant Creutzfeldt-Jakob disease (vCJD) represents haematogenous spread of the disease, we studied the spatial correlation between the vacuolation, prion protein (PrP) deposits, and the blood vessel profiles in the cerebral cortex, hippocampus, dentate gyrus, and cerebellum of 11 cases of the disease. In the majority of areas, there were no significant spatial correlations between either the vacuolation or the diffuse type of PrP deposit and the blood vessels. By contrast, a consistent pattern of spatial correlation was observed between the florid PrP deposits and blood vessels mainly in the cerebral cortex. The frequency of positive spatial correlations was similar in different anatomical areas of the cerebral cortex and in the upper compared with the lower laminae. Hence, with the exception of the florid deposits, the data do not demonstrate a spatial relationship between the pathological features of vCJD and blood vessels. The spatial correlation of the florid deposits and blood vessels may be attributable to factors associated with the blood vessels that promote the aggregation of PrP to form a condensed core rather than reflecting the haematogenous spread of the disease.
Collapse
Affiliation(s)
- R A Armstrong
- Vision Sciences, Aston University, Birmingham, B4 7ET, UK.
| | | | | | | |
Collapse
|
15
|
Guidelines on the selection and use of therapeutic products to treat haemophilia and other hereditary bleeding disorders. Haemophilia 2003; 9:1-23. [PMID: 12558775 DOI: 10.1046/j.1365-2516.2003.00711.x] [Citation(s) in RCA: 94] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Evidence based guidelines are presented on the selection and use of therapeutic products to treat haemophilia. These guidelines offer advice based on the best published scientific and medical information. They will be reviewed regularly by UKHCDO Advisory Committee. Included are details of therapeutic products available in the UK to treat patients with haemophilia and other bleeding disorders and the background information on which the recommendations are based are presented.
Collapse
|
16
|
Abstract
Haemophilia A and B are X-linked disorders resulting from deficiency of Factor VIII and IX, respectively. Clinical sequellae of Factor VIII or IX deficiency include spontaneous and traumatic haemorrhages into joints, soft tissues, and muscles. The cornerstone of therapy has been replacement of the deficient factor, historically with pooled-plasma derivatives. The unfortunate blood-borne infection transmission (such as HIV, hepatitis B and C viruses), inhibitor formation, immunosuppression, and, in certain cases, thrombosis by these products has spawned major advances and innovations in the manufacture of clotting products. Recombinant technology has virtually eliminated transmissible disease risk; yet, the presence of albumin in second and third generation recombinant products raises, at the least, theoretical risk of prions and parvovirus B19. Other non-infectious complications, including inhibitor formation, allergic reactions, and thrombosis, remain formidable concerns. Despite this, recombinant factors remain the most attractive treatment approach for haemophilia. Future improvement awaits the development of safe and effective gene transfer technology.
Collapse
Affiliation(s)
- Kimberly W Schlesinger
- Hemophilia Center of Western Pennsylvania, 3636 Boulevard of the Allies, Pittsburgh, PA 15213-4306, USA
| | | |
Collapse
|