1
|
Naser MA, Sayed AM, Abdelmoez W, El-Wakad MT, Abdo MS. Biodegradable suture development-based albumin composites for tissue engineering applications. Sci Rep 2024; 14:7912. [PMID: 38575715 PMCID: PMC10995150 DOI: 10.1038/s41598-024-58194-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Accepted: 03/26/2024] [Indexed: 04/06/2024] Open
Abstract
Recent advancements in the field of biomedical engineering have underscored the pivotal role of biodegradable materials in addressing the challenges associated with tissue regeneration therapies. The spectrum of biodegradable materials presently encompasses ceramics, polymers, metals, and composites, each offering distinct advantages for the replacement or repair of compromised human tissues. Despite their utility, these biomaterials are not devoid of limitations, with issues such as suboptimal tissue integration, potential cytotoxicity, and mechanical mismatch (stress shielding) emerging as significant concerns. To mitigate these drawbacks, our research collective has embarked on the development of protein-based composite materials, showcasing enhanced biodegradability and biocompatibility. This study is dedicated to the elaboration and characterization of an innovative suture fabricated from human serum albumin through an extrusion methodology. Employing a suite of analytical techniques-namely tensile testing, scanning electron microscopy (SEM), and thermal gravimetric analysis (TGA)-we endeavored to elucidate the physicochemical attributes of the engineered suture. Additionally, the investigation extends to assessing the influence of integrating biodegradable organic modifiers on the suture's mechanical performance. Preliminary tensile testing has delineated the mechanical profile of the Filament Suture (FS), delineating tensile strengths spanning 1.3 to 9.616 MPa and elongation at break percentages ranging from 11.5 to 146.64%. These findings illuminate the mechanical versatility of the suture, hinting at its applicability across a broad spectrum of medical interventions. Subsequent analyses via SEM and TGA are anticipated to further delineate the suture's morphological features and thermal resilience, thereby enriching our comprehension of its overall performance characteristics. Moreover, the investigation delves into the ramifications of incorporating biodegradable organic constituents on the suture's mechanical integrity. Collectively, the study not only sheds light on the mechanical and thermal dynamics of a novel suture material derived from human serum albumin but also explores the prospective enhancements afforded by the amalgamation of biodegradable organic compounds, thereby broadening the horizon for future biomedical applications.
Collapse
Affiliation(s)
- Mohamed A Naser
- Faculty of Engineering, Biomedical Engineering Department, Minia University, Minia, Egypt.
- Faculty of Engineering, Biomedical Engineering Department, Helwan University, Helwan, Egypt.
| | - Ahmed M Sayed
- Faculty of Engineering, Biomedical Engineering Department, Helwan University, Helwan, Egypt.
- EECS Department, MSOE University, Milwaukee, United States.
| | - Wael Abdelmoez
- Faculty of Engineering, Chemical Engineering Department, Minia University, Minia, Egypt
| | - Mohamed Tarek El-Wakad
- Faculty of Engineering and Technology, Future University Egypt, Fifth Settlement, Cairo, Egypt
| | - Mohamed S Abdo
- Faculty of Engineering, Biomedical Engineering Department, Minia University, Minia, Egypt
| |
Collapse
|
2
|
Khader R, Whitehead-Clarke T, Mudera V, Kureshi A. Assessment of mesh shrinkage using fibroblast-populated collagen matrices: a proof of concept for in vitro hernia mesh testing. Hernia 2024; 28:495-505. [PMID: 38180627 PMCID: PMC10997730 DOI: 10.1007/s10029-023-02941-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Accepted: 12/07/2023] [Indexed: 01/06/2024]
Abstract
PURPOSE This study uses free-floating contractile fibroblast-populated collagen matrices (FPCMs) to test the shrinkage of different hernia mesh products. We hope to present this model as a proof of concept for the development of in vitro hernia mesh testing-a novel technology with interesting potential. METHODS FPCMs were formed by seeding Human Dermal Fibroblasts into collagen gels. FPCMs were seeded with three different cell densities and cast at a volume of 500 μl into 24-well plates. Five different mesh products were embedded within the collagen constructs. Gels were left to float freely within culture media and contract over 5 days. Photographs were taken daily and the area of the collagen gel and mesh were measured. Media samples were taken at days 2 and 4 for the purposes of measuring MMP-9 release. After 5 days, dehydrated FPCMs were also examined under light and fluorescence microscopy to assess cell morphology. RESULTS Two mesh products-the mosquito net and large pore lightweight mesh were found to shrink notably more than others. This pattern persisted across all three cell densities. There were no appreciable differences observed in MMP-9 release between products. CONCLUSIONS This study has successfully demonstrated that commercial mesh products can be successfully integrated into free-floating contractile FPCMs. Not only this, but FPCMs are capable of applying a contractile force upon those mesh products-eliciting different levels of contraction between mesh products. Such findings demonstrate this technique as a useful proof of concept for future development of in vitro hernia mesh testing.
Collapse
Affiliation(s)
- R Khader
- Centre for 3D Models of Health and Disease, Division of Surgery & Interventional Science, University College London, London, UK
| | - T Whitehead-Clarke
- Centre for 3D Models of Health and Disease, Division of Surgery & Interventional Science, University College London, London, UK.
| | - V Mudera
- Centre for 3D Models of Health and Disease, Division of Surgery & Interventional Science, University College London, London, UK
| | - A Kureshi
- Centre for 3D Models of Health and Disease, Division of Surgery & Interventional Science, University College London, London, UK
| |
Collapse
|
3
|
Dorkhani E, Darzi B, Foroutani L, Ebrahim Soltani Z, Ahmadi Tafti SM. Characterization and in vivo evaluation of a fabricated absorbable poly(vinyl alcohol)-based hernia mesh. Heliyon 2023; 9:e22279. [PMID: 38045132 PMCID: PMC10689958 DOI: 10.1016/j.heliyon.2023.e22279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 11/07/2023] [Accepted: 11/08/2023] [Indexed: 12/05/2023] Open
Abstract
The most widely taken medical approach toward hernia repair involves the implementation of a prosthetic mesh to cover the herniated site and reinforce the weakened area of the abdominal wall. Biodegradable meshes can serve as biocompatible grafts with a low risk of infection. However, their major complication is associated with a high rate of degradation and hernia recurrence. We proposed a facile and cost-effective method to fabricate a poly(vinyl alcohol)-based mesh, using the solution casting technique. The inclusion of zinc oxide nanoparticles, citric acid, and three cycles of freeze-thaw were intended to ameliorate the mechanical properties of poly(vinyl alcohol). Several characterization, cell culture, and animal studies were conducted. Swelling and water contact angle measurements confirmed good water uptake capacity and wetting behavior of the final mesh sample. The synthesized mesh acquired a high mechanical strength of 52.8 MPa, and its weight loss was decreased to 39 %. No cytotoxicity was found in all samples. In vivo experiments revealed that less adhesion and granuloma formation, greater tissue integration, and notably higher neovascularization rate were resulted from implanting this fabricated hernia mesh, compared to commercial Prolene® mesh. Furthermore, the amount of collagen deposition and influential growth factors were enhanced when rats were treated with the proposed mesh instead of Prolene®.
Collapse
Affiliation(s)
- Erfan Dorkhani
- Research Center for Advanced Technologies in Cardiovascular Medicine, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, Tehran 1411713138, Iran
- School of Chemical Engineering, College of Engineering, University of Tehran, Tehran 1417614411, Iran
| | - Bahareh Darzi
- Research Center for Advanced Technologies in Cardiovascular Medicine, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, Tehran 1411713138, Iran
- School of Chemical Engineering, College of Engineering, University of Tehran, Tehran 1417614411, Iran
| | - Laleh Foroutani
- Research Center for Advanced Technologies in Cardiovascular Medicine, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, Tehran 1411713138, Iran
- Colorectal Research Center, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran 1419733141, Iran
| | - Zahra Ebrahim Soltani
- Experimental Medicine Research Center, Tehran University of Medical Sciences, Tehran, Iran
| | - Seyed Mohsen Ahmadi Tafti
- Research Center for Advanced Technologies in Cardiovascular Medicine, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, Tehran 1411713138, Iran
- Colorectal Research Center, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran 1419733141, Iran
| |
Collapse
|
4
|
Voniatis C, Závoti O, Manikion K, Budavári B, Hajdu AJ. Fabrication of Mechanically Enhanced, Suturable, Fibrous Hydrogel Membranes. MEMBRANES 2023; 13:116. [PMID: 36676923 PMCID: PMC9867240 DOI: 10.3390/membranes13010116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 01/09/2023] [Accepted: 01/10/2023] [Indexed: 06/17/2023]
Abstract
Poly(vinyl-alcohol) hydrogels have already been successfully utilised as drug carrier systems and tissue engineering scaffolds. However, lacking mechanical strength and suturability hinders any prospects for clinical and surgical applications. The objective of this work was to fabricate mechanically robust PVA membranes, which could also withstand surgical manipulation and suturing. Electrospun membranes and control hydrogels were produced with 61 kDa PVA. Using a high-speed rotating cylindrical collector, we achieved fibre alignment (fibre diameter: 300 ± 50 nm). Subsequently, we created multilayered samples with different orientations to achieve multidirectional reinforcement. Finally, utilising glutaraldehyde as a cross-linker, we created insoluble fibrous-hydrogel membranes. Mechanical studies were performed, confirming a fourfold increase in the specific loading capacities (from 0.21 to 0.84 Nm2/g) in the case of the monolayer samples. The multilayered membranes exhibited increased resistance from both horizontal and vertical directions, which varies according to the specific arrangement. Finally, the cross-linked fibrous hydrogel samples not only exhibited specific loading capacities significantly higher than their counterpart bulk hydrogels but successfully withstood suturing. Although cross-linking optimisation and animal experiments are required, these membranes have great prospects as alternatives to current surgical meshes, while the methodology could also be applied in other systems as well.
Collapse
Affiliation(s)
- Constantinos Voniatis
- Department of Surgery, Transplantation and Gastroenterology, Semmelweis University, 1082 Budapest, Hungary
- Laboratory of Nanochemistry, Department of Biophysics and Radiation Biology, Semmelweis University, 1085 Budapest, Hungary
| | - Olivér Závoti
- Laboratory of Nanochemistry, Department of Biophysics and Radiation Biology, Semmelweis University, 1085 Budapest, Hungary
| | - Kenigen Manikion
- Laboratory of Nanochemistry, Department of Biophysics and Radiation Biology, Semmelweis University, 1085 Budapest, Hungary
| | - Bálint Budavári
- Laboratory of Nanochemistry, Department of Biophysics and Radiation Biology, Semmelweis University, 1085 Budapest, Hungary
| | - Angela Jedlovszky Hajdu
- Laboratory of Nanochemistry, Department of Biophysics and Radiation Biology, Semmelweis University, 1085 Budapest, Hungary
| |
Collapse
|
5
|
Hu Q, Wu J, Zhang H, Dong W, Gu Y, Liu S. Designing Double-Layer Multi-Material Composite Patch Scaffold with Adhesion Resistance for Hernia Repair. Macromol Biosci 2022; 22:e2100510. [PMID: 35471592 DOI: 10.1002/mabi.202100510] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 04/12/2022] [Indexed: 11/10/2022]
Abstract
Hernia repair mesh is associated with a number of complications, including adhesions and limited mobility, due to insufficient mechanical strength and non-resorbability. Among them, visceral adhesions are one of the most serious complications of patch repair. In this study, a degradable patch with an anti-adhesive layer was prepared for hernia repair by 3D printing and electrospinning techniques using polycaprolactone (PCL), polyvinyl alcohol (PVA), and soybean peptide (SP). The study into the physicochemical properties of the patch was found that it had adequate mechanical strength requirements (16 N cm-1 ) and large elongation at break, which were superior than commercial polypropylene (PP) patches. In vivo and in vitro experiments showed that human umbilical vein endothelial cells (HUVECs) proliferated well on composite patches, and showed excellent biocompatibility with the host and little adhesion through a rat abdominal wall defect model. In conclusion, the results of this study show that composite patch can effectively reduce the occurrence of adhesions, while the addition of SP in the patch further enhances its biocompatibility. We believe that a regenerative biological patch with great potential in hernia repair provides a new strategy for the development of new biomimetic biodegradable patches. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Qingxi Hu
- Rapid Manufacturing Engineering Center, School of Mechatronical Engineering and Automation, Shanghai University, Shanghai, 200444, China.,Shanghai Key Laboratory of Intelligent Manufacturing and Robotics, Shanghai University, Shanghai, 200072, China.,National Demonstration Center for Experimental Engineering Training Education, Shanghai University, Shanghai, 200444, China
| | - Junjie Wu
- Rapid Manufacturing Engineering Center, School of Mechatronical Engineering and Automation, Shanghai University, Shanghai, 200444, China
| | - Haiguang Zhang
- Rapid Manufacturing Engineering Center, School of Mechatronical Engineering and Automation, Shanghai University, Shanghai, 200444, China.,Shanghai Key Laboratory of Intelligent Manufacturing and Robotics, Shanghai University, Shanghai, 200072, China.,National Demonstration Center for Experimental Engineering Training Education, Shanghai University, Shanghai, 200444, China
| | - Wenpei Dong
- Department of General Surgery, Huadong Hospital, Fudan University, Shanghai, 200040, China
| | - Yan Gu
- Department of General Surgery, Huadong Hospital, Fudan University, Shanghai, 200040, China
| | - Suihong Liu
- Rapid Manufacturing Engineering Center, School of Mechatronical Engineering and Automation, Shanghai University, Shanghai, 200444, China
| |
Collapse
|