1
|
Zerwes S, Kiessling J, Schaefer A, Liebetrau D, Gosslau Y, Bruijnen HK, Hyhlik-Duerr A. Combining Endovascular Aneurysm Sealing with Chimney Grafts - 5 Year Follow-Up after 47 Procedures. Ann Vasc Surg 2023; 96:195-206. [PMID: 37075835 DOI: 10.1016/j.avsg.2023.03.037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 01/31/2023] [Accepted: 03/31/2023] [Indexed: 04/21/2023]
Abstract
BACKGROUND To evaluate longer-term results of a cohort treated with primary chimney endovascular aneurysm sealing (ChEVAS) for complex abdominal aortic aneurysms or secondary ChEVAS after failed endovascular aneurysm repair/endovascular aneurysm sealing. METHODS A single-center study was conducted of 47 consecutive patients (mean age 72 ± 8 years, range 50-91; 38 men) treated with ChEVAS from February 2014 to November 2016 and followed through December 2021. The main outcome measures were all-cause mortality (ACM), aneurysm-related mortality, occurrence of secondary complications and conversion to open surgery. Data are presented as the median (interquartile range [IQR]) and absolute range. RESULTS 35 patients received a primary ChEVAS (=group I) and 12 patients a secondary ChEVAS (=group II). Technical success was 97% (group I) and 92% (group II); 30-day mortality was 3% and 8%, respectively. The median proximal sealing zone length was 20.5 mm (IQR 16, 24; range 10-48) in group I and 26 mm (IQR 17.5, 30; range 8-45) in group II, respectively. During a median time of follow-up of 62 months (range 0-88), ACM amounted to 60% (group I) and 58% (group II); aneurysm mortality was 29% and 8%, respectively. An endoleak was seen in 57% (group I: 15 type Ia endoleaks, four isolated type Ib, and 1 endoleak type V) and 25% (group II: 1 endoleak type Ia, one type II, and 2 type V), aneurysm growth in 40% and 17%, migration in 40% and 17%, resulting in 20% and 25% conversions in group I and II, respectively. Overall a secondary intervention was performed in 51% (group I) and 25% (group II), respectively. The occurrence of complications did not significantly differ between the 2 groups. Neither the number of chimney grafts, nor the thrombus ratio significantly affected the occurrence of abovementioned complications. CONCLUSIONS While initially delivering a high technical success rate, ChEVAS fails to provide acceptable longer-term results both in primary and secondary ChEVAS, resulting in high rates of complications, secondary interventions and open conversions.
Collapse
Affiliation(s)
- Sebastian Zerwes
- Clinic for vascular and endovascular surgery, Medizinische Fakultät, Universität of Augsburg, Augsburg.
| | - Johanna Kiessling
- Clinic for vascular and endovascular surgery, Sankt Gertrauden Krankenhaus, Berlin
| | - Alexander Schaefer
- Clinic for vascular and endovascular surgery, Medizinische Fakultät, Universität of Augsburg, Augsburg
| | - Dominik Liebetrau
- Clinic for vascular and endovascular surgery, Medizinische Fakultät, Universität of Augsburg, Augsburg
| | - Yvonne Gosslau
- Clinic for vascular and endovascular surgery, Medizinische Fakultät, Universität of Augsburg, Augsburg
| | - Hans-Kees Bruijnen
- formerly Clinic for vascular and endovascular surgery, retired vascular surgeon, Medizinische Fakultät, Universität of Augsburg, Augsburg
| | - Alexander Hyhlik-Duerr
- Clinic for vascular and endovascular surgery, Medizinische Fakultät, Universität of Augsburg, Augsburg
| |
Collapse
|
2
|
Mortola L, Ferrero E, Quaglino S, Ferri M, Viazzo A, Manzo P, Gaggiano A. Management of Nellix migration and type Ia endoleak from proximal endovascular aneurysm sealing relining to late open conversion. J Vasc Surg 2021; 74:1204-1213. [PMID: 33684472 DOI: 10.1016/j.jvs.2021.02.035] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Accepted: 02/17/2021] [Indexed: 11/29/2022]
Abstract
BACKGROUND Despite promising early results, mid-term failures of the Nellix endovascular aneurysm sealing (EVAS) system (Endologix Inc, Irvine, Calif) have been reported at higher than expected rates. The management of proximal endoleaks and migration differs from those after conventional endovascular aortic aneurysm repair (EVAR) owing to the peculiar design of the Nellix device. In the present study, we report a monocentric experience in the management of EVAS complications using various techniques. We also performed a comprehensive review of the relevant literature on both open surgical and endovascular management of proximal failure of EVAS from the MEDLINE database. METHODS We retrospectively analyzed the reinterventions for type Ia endoleak and migration after elective infrarenal EVAS at our institution. We collected preoperative, intraoperative, and follow-up data. Open and endovascular techniques are described. Overall survival, aortic-related mortality, and the technical success rate (rate of exclusion of endoleaks) with endovascular techniques were the primary outcomes. RESULTS We performed 101 infrarenal elective EVAS procedures from 2013 to 2018. Of the 101 patients, 20 (19.8%) had required reintervention for proximal sealing failure. The indications were type Ia (Is2, Is3) endoleak, migration >5 mm, sac expansion >5 mm, and secondary rupture. Of the 20 patients, 6 (30%) were treated with endovascular techniques-2 with a chimney Nellix-in-Nellix application and 4 with proximal relining with a covered stent. The remaining 14 patients (70%) were treated with late open conversion (OC). The average time from EVAS to reintervention was 36.1 months (range, 3-65 months). Six patients (30%) had undergone OC in an emergent setting because of secondary rupture. The technical success rate for the patients treated with endovascular reinterventions was 100%. The 30-day mortality was 20% (4 of 20), all emergent cases (four of six emergent repairs; 67%). The overall survival for the 20 patients was 75% (n = 15) at a mean follow-up of 15.1 months (range, 2-47 months). One patient had died after 7 months of non-aortic-related causes. CONCLUSIONS The high reintervention rate of the Nellix graft mandates careful evaluation for its further use with the revised instructions for use, and it should not be used off-label. OC remains the strategy of choice when managing Nellix proximal sealing failures in fit patients. Chimney Nellix-in-Nellix application and transcatheter embolization are feasible alternative techniques. Proximal relining also appears to be an effective alternative to more complex interventions, although it requires further studies for validation.
Collapse
Affiliation(s)
- Lorenzo Mortola
- Vascular and Endovascular Surgery Unit, University Hospital of Novara, Novara, Italy.
| | - Emanuele Ferrero
- Vascular and Endovascular Surgery Unit, Mauriziano Umberto I Hospital, Turin, Italy
| | - Simone Quaglino
- Vascular and Endovascular Surgery Unit, Mauriziano Umberto I Hospital, Turin, Italy
| | - Michelangelo Ferri
- Vascular and Endovascular Surgery Unit, Mauriziano Umberto I Hospital, Turin, Italy
| | - Andrea Viazzo
- Vascular and Endovascular Surgery Unit, Mauriziano Umberto I Hospital, Turin, Italy
| | - Paola Manzo
- Vascular and Endovascular Surgery Unit, Mauriziano Umberto I Hospital, Turin, Italy
| | - Andrea Gaggiano
- Vascular and Endovascular Surgery Unit, Mauriziano Umberto I Hospital, Turin, Italy
| |
Collapse
|
3
|
Quaglino S, Mortola L, Ferrero E, Ferri M, Cirillo S, Lario CV, Negro G, Ricotti A, Gaggiano A. Long-term failure after endovascular aneurysm sealing in a real-life, single-center experience with the Nellix endograft. J Vasc Surg 2020; 73:1958-1965.e1. [PMID: 33278539 DOI: 10.1016/j.jvs.2020.11.029] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2020] [Accepted: 11/05/2020] [Indexed: 10/22/2022]
Abstract
BACKGROUND Endovascular aneurysm sealing (EVAS) is an innovative alternative to conventional endovascular aneurysm repair (EVAR). EVAS relies on sac anchoring without proximal fixation to achieve sealing and should have allowed for the treatment of a broader range of anatomic features compared with standard EVAR. Despite the encouraging early reports, the mid- and long-term follow-up data have shown increased rates of failure. To address the issue, the manufacturer introduced revised instructions for use (IFU) in 2016. The present study reports the outcomes of this system after a median follow-up of 45 months. METHODS Data for all patients electively treated with EVAS at our institution were retrospectively collected. The patients were retrospectively reclassified according to the 2016 revised IFU of the device. All patients in the present series had undergone EVAS for the treatment of infrarenal abdominal aortic aneurysms (AAAs). The primary end point was therapeutic failure: graft migration >5 mm, sac expansion >5 mm, type IA endoleak (Is2 and Is3 using the Van den Ham classification), type Ib endoleak, and secondary rupture. The overall mortality, aortic-related mortality, and reintervention rates were also analyzed. RESULTS A total of 101 patients had undergone elective treatment by EVAS from 2013 to 2018 for infrarenal AAAs. The median follow-up was 3.75 years. Therapeutic failure was observed in 31 of the 101 patients (30.7%), with no significant difference between the in-IFU and off-IFU 2016 subgroups. Failure occurred at a median interval of 34 months from the index procedure. Of the 101 patients, 6.9% had presented with secondary rupture. Freedom from aneurysm-related mortality was 96.9% at 1 and 2 years and 89.9% at 5 years. Freedom from reintervention decreased over time: 94.7% at 1 year, 77% at 4 years, and 52.1% at 6 years. Of the 101 patients, 14 (13.9%) had undergone emergent or elective graft explantation. CONCLUSIONS EVAS performed worse than conventional endografts for several critical end points, regardless of any preoperative anatomic parameters. The incidence of therapeutic failures tended to increase over time, especially 4 years after the index procedure.
Collapse
Affiliation(s)
- Simone Quaglino
- Vascular and Endovascular Surgery Unit, Umberto I Mauriziano Hospital, Turin, Italy.
| | - Lorenzo Mortola
- Vascular and Endovascular Surgery Unit, University Hospital of Novara, Novara, Italy
| | - Emanuele Ferrero
- Vascular and Endovascular Surgery Unit, Umberto I Mauriziano Hospital, Turin, Italy
| | - Michelangelo Ferri
- Vascular and Endovascular Surgery Unit, Umberto I Mauriziano Hospital, Turin, Italy
| | | | | | | | - Andrea Ricotti
- Department of Public Health Sciences, School of Health Statistics and Biometry, University of Turin, Turin, Italy
| | - Andrea Gaggiano
- Vascular and Endovascular Surgery Unit, Umberto I Mauriziano Hospital, Turin, Italy
| |
Collapse
|
4
|
Zerwes S, Kiessling J, Liebetrau D, Jakob R, Gosslau Y, Bruijnen HK, Hyhlik-Duerr A. Open Conversion After Endovascular Aneurysm Sealing: Technical Features and Clinical Outcomes in 44 Patients. J Endovasc Ther 2020; 28:332-341. [DOI: 10.1177/1526602820971830] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Purpose To evaluate the technical features and clinical results after open conversion for complications following endovascular aneurysm sealing (EVAS). Materials and Methods From July 2013 to February 2020, 44 patients (mean age 72±8 years; 36 men) underwent an open conversion due to EVAS complications in a single center. Data were collected on patient characteristics, reasons for conversion, characteristics and duration of the procedure, condition of the polymer, blood loss, time in the intensive care unit (ICU), and intra/postoperative complications. The main outcome measure was mortality at 30 days and in follow-up. Data are presented as the median (IQR) and absolute range. Results On average, the open conversion took place 3 years after the initial EVAS implantation [median 37 months (IQR 23, 50); range 0–64]. Most patients were converted due migration (82%), aneurysm growth (77%), and/or endoleak (75%), with 21 patients (48%) having all 3 events. Less frequent diagnoses were aneurysm rupture (n=7), aortic infection (n=3), technical failure during implantation (n=2), and graft thrombosis (n=1). The majority of patients (n=26) were asymptomatic and converted electively, but 9 were operated on urgently and 9 emergently (7 late rupture and 2 due to technical failure). The median procedure duration was 178 minutes (IQR 149, 223; range 87–417), the median blood loss was 1100 mL (IQR 600, 2600; range 300–5000). Polymer degradation was mentioned in the operative reports of 18 cases (41%). Patients stayed a median of 3 days (IQR 2, 7; range 1–35) in the ICU, while the median length of stay in the hospital was 14 days (IQR 10, 20; range 0–93). The 30-day mortality was 23% (n=10). During a median follow-up of 3 months (IQR 0, 11; range 0–38), no additional deaths occurred, but 12 patients suffered from an adverse event. There were 3 cases of wound dehiscence after laparotomy, 2 cases of leg ischemia, 2 cases of renal failure, and individual cases of urinary obstruction, urinoma, paralytic ileus, gastrointestinal bleeding, and postoperative delirium. A non-elective setting was associated with a significantly increased mortality of 33% in urgent cases and 56% in emergent cases (p=0.007). Based on these results an algorithm for the management of EVAS complications was developed. Conclusion The significantly increased mortality associated with nonelective conversions highlights the need for active surveillance. The presented algorithm offers a structured tool to avoid emergency conversions.
Collapse
Affiliation(s)
- Sebastian Zerwes
- Clinic for Vascular and Endovascular Surgery, Medizinische Fakultät, Universität Augsburg, Germany
| | - Johanna Kiessling
- Clinic for Vascular and Endovascular Surgery, Medizinische Fakultät, Universität Augsburg, Germany
| | - Dominik Liebetrau
- Clinic for Vascular and Endovascular Surgery, Medizinische Fakultät, Universität Augsburg, Germany
| | - Rudolf Jakob
- Clinic for Vascular and Endovascular Surgery, Medizinische Fakultät, Universität Augsburg, Germany
| | - Yvonne Gosslau
- Clinic for Vascular and Endovascular Surgery, Medizinische Fakultät, Universität Augsburg, Germany
| | - Hans-Kees Bruijnen
- Clinic for Vascular and Endovascular Surgery, Medizinische Fakultät, Universität Augsburg, Germany
| | - Alexander Hyhlik-Duerr
- Clinic for Vascular and Endovascular Surgery, Medizinische Fakultät, Universität Augsburg, Germany
| |
Collapse
|
5
|
Zerwes S, Bruijnen HK, Gosslau Y, Jakob R, Hyhlik-Dürr A. Influence of the Revised Nellix Instructions for Use on Outcomes After Endovascular Aneurysm Sealing. J Endovasc Ther 2018; 25:418-425. [DOI: 10.1177/1526602818781353] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Purpose: To evaluate the impact of the revised Nellix instructions for use (IFU) from 2016 on clinical outcomes and anatomic applicability by retrospectively applying them to a cohort treated with endovascular aneurysm sealing according to the original IFU 2013. Methods: A single-center study was conducted of 100 consecutive patients (mean age 72±8 years, range 46–91; 89 men) treated electively with standard bilateral EVAS from July 2013 to August 2015 and followed through December 2017. Procedures previously classified within and outside the original IFU from 2013 (75 and 25, respectively) were reclassified according to the revised IFU 2016 (34 and 66, respectively). Stepwise backward logistic regression analysis was performed to evaluate the prognostic value of specific anatomic features for the development of endoleak and/or migration. Results: The single most important morphologic feature disqualifying patients from being within IFU 2016 was a thrombus ratio >1.4 (36 of 41 reclassified patients). Overall technical success was 98% (100% within vs 97% outside IFU 2016, p=0.323) and 30-day mortality was 3% (0% within vs 5% outside IFU 2016, p=0.251). During a median follow-up of 31 months (range 0–53), overall mortality was 21% (15% within vs 24% outside IFU 2016, p=0.469); aneurysm-related mortality was 8% (3% within vs 11% outside IFU 2016, p=0.533). Twenty-six patients developed an endoleak (6 within vs 20 outside IFU 2016, p=0.172) and 23 had migration (4 within vs 19 outside IFU 2016, p=0.088). Both proximal neck length <10 mm and neck angulation >60° were positive predictors for the development of endoleak and/or migration. A reintervention was performed in 26 patients (7 within vs 19 outside IFU 2016, p=0.376). While a significant difference was found between the within vs outside IFU 2016 groups with regard to freedom from migration (p=0.026) and the composite freedom from endoleak and/or migration (p=0.021), there were no significant differences in survival (p=0.201) or freedom from reintervention (p=0.505), suggesting a limited effectiveness of the new IFU 2016. Conclusion: The IFU 2016 reduced the anatomic applicability to 34% from 75% for the original IFU 2013. The lack of significant intergroup differences in terms of survival and reinterventions suggests a limited effectiveness of the new IFU 2016.
Collapse
Affiliation(s)
- Sebastian Zerwes
- Department of Vascular and Endovascular Surgery, Klinikum Augsburg, Germany
| | - Hans-Kees Bruijnen
- Department of Vascular and Endovascular Surgery, Klinikum Augsburg, Germany
| | - Yvonne Gosslau
- Department of Vascular and Endovascular Surgery, Klinikum Augsburg, Germany
| | - Rudolf Jakob
- Department of Vascular and Endovascular Surgery, Klinikum Augsburg, Germany
| | | |
Collapse
|
6
|
Vos CG, van Veen R, Schuurmann RC, Boersen JT, van den Heuvel DA, de Vries JPP. Subtraction computed tomography imaging to detect endoleaks after endovascular aneurysm sealing with sac anchoring. Vascular 2017; 26:393-399. [PMID: 29212423 DOI: 10.1177/1708538117746041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Background Early detection of small type I endoleaks after endovascular aneurysm sealing is mandatory because they can rapidly progress and lead to severe complications. Recognition of endoleaks can be challenging due to the appearances on computed tomography unique to endovascular aneurysm sealing. We aimed to validate the accuracy and added value of subtraction computed tomography imaging using a post-processing software algorithm to improve detection of endovascular aneurysm sealing-associated endoleaks on postoperative surveillance imaging. Methods The computed tomography scans of 17 patients (16 males; median age: 78, range: 72-84) who underwent a post-endovascular aneurysm sealing computed tomography including both non-contrast and arterial phase series were used to validate the post processing software algorithm. Subtraction images are produced after segmentation and alignment. Initial alignment of the stent segmentations is automatically performed by registering the geometric centers of the 3D coordinates of both computed tomography series. Accurate alignment is then performed by translation with an iterative closest point algorithm. Accuracy of alignment was determined by calculating the root mean square error between matched 3D coordinates of stent segmentations. Results The median root mean square error after initial center of gravity alignment was 0.62 mm (IQR: 0.55-0.80 mm), which improved to 0.53 mm (IQR: 0.47-0.69 mm) after the ICP alignment. Visual inspection showed good alignment and no manual adjustment was necessary. Conclusions The possible merit of subtraction computed tomography imaging for the detection of small endoleaks during surveillance after endovascular aneurysm sealing was illustrated. Alignment of different computed tomography phases using a software algorithm was very accurate. Further studies are needed to establish the exact role of this technique during surveillance after endovascular aneurysm sealing compared to less invasive techniques like contrast-enhanced ultrasound.
Collapse
Affiliation(s)
- Cornelis G Vos
- 1 Department of Surgery, Onze Lieve Vrouwe Gasthuis, Amsterdam, The Netherlands
| | - Ruben van Veen
- 2 Department of Vascular Surgery, St. Antonius Hospital, Nieuwegein, The Netherlands
| | - Richte Cl Schuurmann
- 2 Department of Vascular Surgery, St. Antonius Hospital, Nieuwegein, The Netherlands
- 3 Technical Medicine, Faculty of Science and Technology, University of Twente, Enschede, The Netherlands
| | - Johannes T Boersen
- 2 Department of Vascular Surgery, St. Antonius Hospital, Nieuwegein, The Netherlands
| | | | - Jean-Paul Pm de Vries
- 2 Department of Vascular Surgery, St. Antonius Hospital, Nieuwegein, The Netherlands
| |
Collapse
|
7
|
A Peculiar Case of Type 1 Endoleak after Nellix Endovascular Aneurysm Sac Sealing: Clinical Presentation and Management. Ann Vasc Surg 2017; 44:423.e7-423.e11. [DOI: 10.1016/j.avsg.2017.05.025] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2017] [Revised: 04/30/2017] [Accepted: 05/12/2017] [Indexed: 11/18/2022]
|
8
|
Thompson M, Youssef M, Jacob R, Zerwes S, Reijnen M, Szopinski P, Berg P, Oszkinis G, Holden A. Early Experience With Endovascular Aneurysm Sealing in Combination With Parallel Grafts for the Treatment of Complex Abdominal Aneurysms: The ASCEND Registry. J Endovasc Ther 2017; 24:764-772. [DOI: 10.1177/1526602817731103] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Affiliation(s)
| | - Marwan Youssef
- Department of Vascular Surgery, University Hospital, Mainz, Germany
| | - Rudolf Jacob
- Department of Vascular Surgery, Augsburg Hospital, Augsburg, Germany
| | - Sebastian Zerwes
- Department of Vascular Surgery, Augsburg Hospital, Augsburg, Germany
| | - Michel Reijnen
- Department of Vascular Surgery, Rijnstate Hospital, Arnhem, the Netherlands
| | | | - Patrick Berg
- Department of Vascular Surgery, Marienhospital Kevelaer, Germany
| | | | - Andrew Holden
- Department of Interventional Radiology, Auckland City Hospital, Auckland, New Zealand
| |
Collapse
|
9
|
Ünlü Ç, Schuurmann RCL, de Vries JPPM. The Nellix device: review of indications and outcome. Expert Rev Med Devices 2017; 14:651-656. [DOI: 10.1080/17434440.2017.1351876] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Affiliation(s)
- Ç. Ünlü
- Department of Surgery, Noordwest Ziekenhuisgroep, Alkmaar, The Netherlands
| | - R. C. L. Schuurmann
- Department of Vascular Surgery, St. Antonius Hospital, Nieuwegein, The Netherlands
| | - J. P. P. M. de Vries
- Department of Vascular Surgery, St. Antonius Hospital, Nieuwegein, The Netherlands
| |
Collapse
|