1
|
Cai R, Deng L, Zhang H, Zhang H, Wu Q. A non-invasive preoperative prediction model for predicting axillary lymph node metastasis in breast cancer based on a machine learning approach: combining ultrasonographic parameters and breast gamma specific imaging features. Radiat Oncol 2024; 19:63. [PMID: 38802938 PMCID: PMC11131273 DOI: 10.1186/s13014-024-02453-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Accepted: 05/13/2024] [Indexed: 05/29/2024] Open
Abstract
BACKGROUND The most common route of breast cancer metastasis is through the mammary lymphatic network. An accurate assessment of the axillary lymph node (ALN) burden before surgery can avoid unnecessary axillary surgery, consequently preventing surgical complications. In this study, we aimed to develop a non-invasive prediction model incorporating breast specific gamma image (BSGI) features and ultrasonographic parameters to assess axillary lymph node status. MATERIALS AND METHODS Cohorts of breast cancer patients who underwent surgery between 2012 and 2021 were created (The training set included 1104 ultrasound images and 940 BSGI images from 235 patients, the test set included 568 ultrasound images and 296 BSGI images from 99 patients) for the development of the prediction model. six machine learning (ML) methods and recursive feature elimination were trained in the training set to create a strong prediction model. Based on the best-performing model, we created an online calculator that can make a linear predictor in patients easily accessible to clinicians. The receiver operating characteristic (ROC) and calibration curve are used to verify the model performance respectively and evaluate the clinical effectiveness of the model. RESULTS Six ultrasonographic parameters (transverse diameter of tumour, longitudinal diameter of tumour, lymphatic echogenicity, transverse diameter of lymph nodes, longitudinal diameter of lymph nodes, lymphatic color Doppler flow imaging grade) and one BSGI features (axillary mass status) were selected based on the best-performing model. In the test set, the support vector machines' model showed the best predictive ability (AUC = 0.794, sensitivity = 0.641, specificity = 0.8, PPV = 0.676, NPV = 0.774 and accuracy = 0.737). An online calculator was established for clinicians to predict patients' risk of ALN metastasis ( https://wuqian.shinyapps.io/shinybsgi/ ). The result in ROC showed the model could benefit from incorporating BSGI feature. CONCLUSION This study developed a non-invasive prediction model that incorporates variables using ML method and serves to clinically predict ALN metastasis and help in selection of the appropriate treatment option.
Collapse
Affiliation(s)
- Ranze Cai
- Department of Neurosurgery, Zhongshan Hospital (Xiamen), Fudan University, Xiamen, Fujian Province, 361006, China
| | - Li Deng
- Department of General Surgery, Shanghai Public Health Clinical Center, Shanghai, 201508, China
| | - Hua Zhang
- Department of General Surgery, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Hongwei Zhang
- Department of General Surgery, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Qian Wu
- Department of General Surgery, Fudan University Affiliated Huadong Hospital, Shanghai, 200040, China.
| |
Collapse
|
2
|
Li Y, Zhang Y, Yu Q, He C, Yuan X. Intelligent scoring system based on dynamic optical breast imaging for early detection of breast cancer. BIOMEDICAL OPTICS EXPRESS 2024; 15:1515-1527. [PMID: 38495695 PMCID: PMC10942703 DOI: 10.1364/boe.515135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 01/06/2024] [Accepted: 01/31/2024] [Indexed: 03/19/2024]
Abstract
Early detection of breast cancer can significantly improve patient outcomes and five-year survival in clinical screening. Dynamic optical breast imaging (DOBI) technology reflects the blood oxygen metabolism level of tumors based on the theory of tumor neovascularization, which offers a technical possibility for early detection of breast cancer. In this paper, we propose an intelligent scoring system integrating DOBI features assessment and a malignancy score grading reporting system for early detection of breast cancer. Specifically, we build six intelligent feature definition models to depict characteristics of regions of interest (ROIs) from location, space, time and context separately. Similar to the breast imaging-reporting and data system (BI-RADS), we conclude the malignancy score grading reporting system to score and evaluate ROIs as follows: Malignant (≥ 80 score), Likely Malignant (60-80 score), Intermediate (35-60 score), Likely Benign (10-35 score), and Benign (<10 score). This system eliminates the influence of subjective physician judgments on the assessment of the malignant probability of ROIs. Extensive experiments on 352 Chinese patients demonstrate the effectiveness of the proposed system compared to state-of-the-art methods.
Collapse
Affiliation(s)
- Yaoyao Li
- Hangzhou Institute of Technology, Xidian University, Qiannong Dong Road No. 8, Hangzhou, Zhejiang, 311231, China
| | - Yipei Zhang
- Hangzhou Institute of Technology, Xidian University, Qiannong Dong Road No. 8, Hangzhou, Zhejiang, 311231, China
| | - Qiang Yu
- Hangzhou Institute of Technology, Xidian University, Qiannong Dong Road No. 8, Hangzhou, Zhejiang, 311231, China
| | - Chenglong He
- Hangzhou Institute of Technology, Xidian University, Qiannong Dong Road No. 8, Hangzhou, Zhejiang, 311231, China
| | - Xiguo Yuan
- Hangzhou Institute of Technology, Xidian University, Qiannong Dong Road No. 8, Hangzhou, Zhejiang, 311231, China
| |
Collapse
|
3
|
Patel MM, Adrada BE, Fowler AM, Rauch GM. Molecular Breast Imaging and Positron Emission Mammography. PET Clin 2023; 18:487-501. [PMID: 37258343 DOI: 10.1016/j.cpet.2023.04.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
There is growing interest in application of functional imaging modalities for adjunct breast imaging due to their unique ability to evaluate molecular/pathophysiologic changes, not visible by standard anatomic breast imaging. This has led to increased use of nuclear medicine dedicated breast-specific single photon and coincidence imaging systems for multiple indications, such as supplemental screening, staging of newly diagnosed breast cancer, evaluation of response to neoadjuvant treatment, diagnosis of local disease recurrence in the breast, and problem solving. Studies show that these systems maybe especially useful for specific subsets of patients, not well served by available anatomic breast imaging modalities.
Collapse
Affiliation(s)
- Miral M Patel
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, 1515 Holcombe, CPB5.3208, Houston, TX 77030, USA.
| | - Beatriz Elena Adrada
- Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, 1515 Holcombe, CPB5.3208, Houston, TX 77030, USA
| | - Amy M Fowler
- Department of Radiology, Section of Breast Imaging and Intervention, University of Wisconsin - Madison, 600 Highland Avenue, Madison, WI 53792-3252, USA; Department of Medical Physics, University of Wisconsin Carbone Cancer Center, University of Wisconsin-Madison, 600 Highland Avenue, Madison, WI 53792-3252, USA
| | - Gaiane M Rauch
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, 1515 Holcombe, Unit 1473, Houston, TX 77030, USA; Department of Breast Imaging, The University of Texas MD Anderson Cancer Center, 1515 Holcombe, Unit 1473, Houston, TX 77030, USA
| |
Collapse
|
4
|
Ekinci M, Alencar LMR, Lopes AM, Santos-Oliveira R, İlem-Özdemir D. Radiolabeled Human Serum Albumin Nanoparticles Co-Loaded with Methotrexate and Decorated with Trastuzumab for Breast Cancer Diagnosis. J Funct Biomater 2023; 14:477. [PMID: 37754891 PMCID: PMC10532481 DOI: 10.3390/jfb14090477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 09/02/2023] [Accepted: 09/14/2023] [Indexed: 09/28/2023] Open
Abstract
Breast cancer is a leading cause of cancer-related mortality among women worldwide, with millions of new cases diagnosed yearly. Addressing the burden of breast cancer mortality requires a comprehensive approach involving early detection, accurate diagnosis, effective treatment, and equitable access to healthcare services. In this direction, nano-radiopharmaceuticals have shown potential for enhancing breast cancer diagnosis by combining the benefits of nanoparticles and radiopharmaceutical agents. These nanoscale formulations can provide improved imaging capabilities, increased targeting specificity, and enhanced sensitivity for detecting breast cancer lesions. In this study, we developed and evaluated a novel nano-radio radiopharmaceutical, technetium-99m ([99mTc]Tc)-labeled trastuzumab (TRZ)-decorated methotrexate (MTX)-loaded human serum albumin (HSA) nanoparticles ([99mTc]-TRZ-MTX-HSA), for the diagnosis of breast cancer. In this context, HSA and MTX-HSA nanoparticles were prepared. Conjugation of MTX-HSA nanoparticles with TRZ was performed using adsorption and covalent bonding methods. The prepared formulations were evaluated for particle size, PDI value, zeta (ζ) potential, scanning electron microscopy analysis, encapsulation efficiency, and loading capacity and cytotoxicity on MCF-7, 4T1, and MCF-10A cells. Finally, the nanoparticles were radiolabeled with [99mTc]Tc using the direct radiolabeling method, and cellular uptake was performed with the nano-radiopharmaceutical. The results showed the formation of spherical nanoparticles, with a particle size of 224.1 ± 2.46 nm, a PDI value of 0.09 ± 0.07, and a ζ potential value of -16.4 ± 0.53 mV. The encapsulation efficiency of MTX was found to be 32.46 ± 1.12%, and the amount of TRZ was 80.26 ± 1.96%. The labeling with [99mTc]Tc showed a high labeling efficiency (>99%). The cytotoxicity studies showed no effect, and the cellular uptake studies showed 97.54 ± 2.16% uptake in MCF-7 cells at the 120th min and were found to have a 3-fold higher uptake in cancer cells than in healthy cells. In conclusion, [99mTc]Tc-TRZ-MTX-HSA nanoparticles are promising for diagnosing breast cancer and evaluating the response to treatment in breast cancer patients.
Collapse
Affiliation(s)
- Meliha Ekinci
- Faculty of Pharmacy, Department of Radiopharmacy, Ege University, Bornova, Izmir 35040, Turkey;
| | | | - André Moreni Lopes
- Department of Biotechnology, Engineering School of Lorena, University of São Paulo (EEL/USP), São Paulo 12612-550, Brazil;
| | - Ralph Santos-Oliveira
- Laboratory of Nanoradiopharmacy and Synthesis of Novel Radiopharmaceuticals, Nuclear Engineering Institute, Brazilian Nuclear Energy Commission, Rio de Janeiro 21941-906, Brazil;
- Laboratory of Radiopharmacy and Nanoradiopharmaceuticals, State University of Rio de Janeiro, Rio de Janeiro 23070-200, Brazil
| | - Derya İlem-Özdemir
- Faculty of Pharmacy, Department of Radiopharmacy, Ege University, Bornova, Izmir 35040, Turkey;
| |
Collapse
|
5
|
Lopez BP, Kappadath SC. Monte Carlo-derived 99m Tc uptake quantification with commercial planar MBI: Tumor and breast activity concentrations. Med Phys 2023; 50:4388-4398. [PMID: 36625713 PMCID: PMC10331527 DOI: 10.1002/mp.16213] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 12/23/2022] [Accepted: 01/01/2023] [Indexed: 01/11/2023] Open
Abstract
BACKGROUND Current molecular breast imaging (MBI) images are limited to qualitative evaluation, not absolute measurement, of 99m Tc uptake in benign and malignant breast tissues. PURPOSE This work assesses the accuracy of previously-published and newly-proposed tumor and normal breast tissue 99m Tc uptake MBI measurements using simulations of a commercial dual-headed planar MBI system under typical clinical and acquisition protocols. METHODS Quantification techniques were tested in over 4000 simulated acquisitions of spherical and ellipsoid tumors with clinically relevant uptake conditions using a validated Monte Carlo application of the GE Discovery NM750b system. The evaluated techniques consisted of four tumor total activity methodologies (two single-detector-based and two geometric-mean-based), two tumor MBI volume methodologies (diameter-based and ROI-based), and two normal tissue activity concentration methodologies (single-detector-based and geometric-mean-based). The most accurate of these techniques were then used to estimate tumor activity concentrations and tumor to normal tissue relative activity concentrations (RC). RESULTS Single-detector techniques for tumor total activity quantification achieved mean (standard deviation) relative errors of 0.2% (4.3%) and 1.6% (4.4%) when using the near and far detector images, respectively and were more accurate and precise than the measured 8.1% (5.8%) errors of a previously published geometric-mean technique. Using these activity estimates and the true tumor volumes resulted in tumor activity concentration and RC errors within 10% of simulated values. The precision of tumor activity concentration and RC when using only MBI measurements were largely driven by the errors in estimating tumor MBI volume using planar images (± 30% inter-quartile range). CONCLUSIONS Planar MBI images were shown to accurately and reliably be used to estimate tumor total activities and normal tissue activity concentrations in this simulation study. However, volumetric tumor uptake measurements (i.e., absolute and relative concentrations) are limited by inaccuracies in MBI volume estimation using two-dimensional images, highlighting the need for either tomographic MBI acquisitions or anatomical volume estimates for accurate three-dimensional tumor uptake estimates.
Collapse
Affiliation(s)
- Benjamin P Lopez
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
- MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas, USA
| | - S Cheenu Kappadath
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
- MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas, USA
| |
Collapse
|
6
|
van Loevezijn AA, Corion CL, Zeillemaker AM, Wijers LM, Smithuis RH, Valdés Olmos RA, van der Hage JA, de Geus-Oei LF, Benard M, Pereira Arias-Bouda LM. Clinical impact of molecular breast imaging as adjunct diagnostic modality in evaluation of indeterminate breast abnormalities and unresolved diagnostic concerns. Nucl Med Commun 2023; 44:417-426. [PMID: 36897051 PMCID: PMC10171295 DOI: 10.1097/mnm.0000000000001684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 02/24/2023] [Indexed: 03/11/2023]
Abstract
PURPOSE Improvements in molecular breast imaging (MBI) have increased the use of MBI as adjunct diagnostic modality and alternative to MRI. We aimed to assess the value of MBI in patients with equivocal breast lesions on conventional imaging, especially in terms of its ability to rule out malignancy. METHODS We selected patients who underwent MBI in addition to conventional diagnostics due to equivocal breast lesions between 2012 and 2015. All patients underwent digital mammography, target ultrasound and MBI. MBI was performed using a single-head Dilon 6800 gamma camera after administration of 600 MBq 99m Tc-sestamibi. Imaging was reported according to BI-RADS classification and compared with pathology or follow-up of ≥6 months. RESULTS Of 226 women included, pathology was obtained in 106 (47%) and (pre)malignant lesions were found in 25 (11%). Median follow-up was 5.4 years (IQR 3.9-7.1). Sensitivity was higher for MBI compared to conventional diagnostics (84% vs. 32%; P = 0.002), identifying malignancy in 21 and 6 patients, respectively, but specificity did not differ (86% vs. 81%; P = 0.161). Positive and negative predictive value were 43% and 98% for MBI and 17% and 91% for conventional diagnostics. MBI was discordant with conventional diagnostics in 68 (30%) patients and correctly changed diagnosis in 46 (20%) patients, identifying 15 malignant lesions. In subgroups with nipple discharge ( N = 42) and BI-RADS 3 lesions ( N = 113) MBI detected 7 of 8 occult malignancies. CONCLUSION MBI correctly adjusted treatment in 20% of patients with diagnostic concerns after conventional work-up, and could rule out malignancy with a high negative predictive value of 98%.
Collapse
Affiliation(s)
- Ariane A. van Loevezijn
- Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek, Amsterdam
| | | | | | | | | | | | | | - Lioe-Fee de Geus-Oei
- Department of Radiology, Section of Nuclear Medicine
- Biomedical Photonic Imaging Group, University of Twente, Enschede
| | - Menno Benard
- Department of Research and Education, Alrijne Hospital
| | - Lenka M. Pereira Arias-Bouda
- Department of Radiology, Section of Nuclear Medicine
- Department of Nuclear Medicine, Alrijne hospital, Leiderdorp, The Netherlands
| |
Collapse
|
7
|
Pereslucha AM, Wenger DM, Morris MF, Aydi ZB. Invasive Lobular Carcinoma: A Review of Imaging Modalities with Special Focus on Pathology Concordance. Healthcare (Basel) 2023; 11:healthcare11050746. [PMID: 36900751 PMCID: PMC10000992 DOI: 10.3390/healthcare11050746] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 02/26/2023] [Accepted: 03/01/2023] [Indexed: 03/06/2023] Open
Abstract
Invasive lobular cancer (ILC) is the second most common type of breast cancer. It is characterized by a unique growth pattern making it difficult to detect on conventional breast imaging. ILC can be multicentric, multifocal, and bilateral, with a high likelihood of incomplete excision after breast-conserving surgery. We reviewed the conventional as well as newly emerging imaging modalities for detecting and determining the extent of ILC- and compared the main advantages of MRI vs. contrast-enhanced mammogram (CEM). Our review of the literature finds that MRI and CEM clearly surpass conventional breast imaging in terms of sensitivity, specificity, ipsilateral and contralateral cancer detection, concordance, and estimation of tumor size for ILC. Both MRI and CEM have each been shown to enhance surgical outcomes in patients with newly diagnosed ILC that had one of these imaging modalities added to their preoperative workup.
Collapse
Affiliation(s)
- Alicia M Pereslucha
- Department of Surgery, University of Arizona College of Medicine-Phoenix, Phoenix, AZ 85006, USA
| | - Danielle M Wenger
- College of Medicine-Phoenix, University of Arizona, Phoenix, AZ 85004, USA
| | - Michael F Morris
- Division of Diagnostic Imaging, Banner MD Anderson Cancer Center, Phoenix, AZ 85006, USA
- Department of Radiology, Banner University Medical Center-Phoenix, Phoenix, AZ 85006, USA
| | - Zeynep Bostanci Aydi
- Department of Surgery, University of Arizona College of Medicine-Phoenix, Phoenix, AZ 85006, USA
- Department of Surgical Oncology, Banner MD Anderson Cancer Center, Phoenix, AZ 85006, USA
- Correspondence:
| |
Collapse
|
8
|
Abstract
BACKGROUND. Molecular breast imaging (MBI) is used for various breast imaging indications. An MBI lexicon has been developed, although the likelihood of malignancy of the lexicon descriptors has not been assessed to our knowledge. OBJECTIVE. The purpose of this article was to evaluate the PPV for malignancy of the MBI lexicon imaging descriptors. METHODS. This retrospective study included MBI examinations performed from August 1, 2005, through August 31, 2017, that were positive (BI-RADS analogous categories 0, 3, 4, 5, or 6) according to the clinical report and had an available reference standard. Examinations were performed using dual-detector cadmium zinc telluride MBI systems after injection of 99mTc sestamibi. Category 3 lesions had pathologic correlation, at least 2 years of imaging follow-up, or final resolution on follow-up imaging as category 1 or 2; category 4 and 5 lesions had pathologic correlation. MBI examinations were reviewed by one of two radiologists to assess lesions on the basis of the published MBI lexicon for type (mass vs nonmass uptake), distribution (if nonmass uptake), uptake intensity, and number of MBI views on which the lesion was seen. PPV for malignancy was summarized. RESULTS. The analysis included 643 lesions (479 benign, 164 malignant; 83 mass, 560 nonmass uptake) in 509 patients (median age, 56 years). PPV was 73.5% (61/83) for masses and 18.4% (103/560) for nonmass uptake. Among the nonmass uptake lesions, PPV was 36.2% (17/47) for segmental, 20.1% (77/384) for focal, 30.8% (4/13) for diffuse, and 4.3% (5/116) for regional or multiple regional distribution. PPV was 5.3% (5/94) for one view, 15.2% (32/210) for two views, 14.6% (13/89) for three views, and 45.4% (113/249) for four views showing the lesion. PPV was 14.0% (43/307) for mild, 22.4% (51/228) for moderate, and 64.8% (70/108) for marked uptake intensity. CONCLUSION. The MBI lexicon lesion descriptors are associated with likelihood of malignancy. PPV was higher for masses, lesions seen on multiple MBI views, and lesions with marked uptake intensity. Among nonmass uptake lesions, PPV was highest for those with segmental distribution. CLINICAL IMPACT. Insight into the likelihood of malignancy associated with the MBI lexicon descriptors can inform radiologists' interpretations and guide potential future incorporation of the MBI lexicon into the ACR BI-RADS Atlas.
Collapse
|
9
|
Robinson KA, Staack SO, Patel BK, Lorans R, Sharpe RE, Kling JM, Maimone S, Pizzitola VJ. The Dense Breast Clinic: Initial Experience of a Patient-Centered Breast Imaging Clinic. JOURNAL OF BREAST IMAGING 2022; 4:582-589. [PMID: 38416998 DOI: 10.1093/jbi/wbac063] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Indexed: 03/01/2024]
Abstract
OBJECTIVE Establish a radiologist-run consultation clinic to review breast density and supplemental screening exams (SSEs) directly with patients in response to breast density reporting laws. METHODS Breast radiologists opened and staffed a clinic for formal patient consultations regarding breast density and SSEs. An IRB-approved questionnaire assessed patient knowledge of breast density, SSEs, and encounter satisfaction. Comparative statistical analyses were performed on knowledge-based questions. RESULTS From February 2019 to February 2021, 294 reimbursable consultations were performed with 215 patients completing pre- and post-consultation questionnaires (survey response rate, 73%). Median patient age was 58 years (range, 34-86 years) and 9% (19/210) had a personal history of breast cancer. An increase in patient knowledge of breast density and SSEs was observed as follows: breast density categories (9% correct pre-consultation (20/215), 86% correct post-consultation (185/215), P < 0.001), dense breast effects on cancer risk (39% correct pre-consultation (83/215), 84% post-consultation (180/215)), mammogram sensitivity (90% correct pre-consultation (193/215), 94% post-consultation (201/215)), and increased cancer detection with SSEs (82% correct pre-consultation (177/215), 95% post-consultation (205/215)) (P < 0.001). Post-consultation, 96% (200/209) were satisfied with the usefulness of information, 89% (186/209) strongly agreed they had sufficient knowledge of SSEs, and 81% (167/205) agreed they would like future opportunities to meet with a breast radiologist. CONCLUSION A consultation clinic staffed by breast radiologists focused on breast density and supplemental breast cancer screening can provide personalized patient counseling, engage patients in shared decision making, assist referring clinicians, and support high quality patient-centered care.
Collapse
Affiliation(s)
| | - Sasha O Staack
- Mayo Clinic Arizona, Department of Radiology, Phoenix, AZ, USA
| | - Bhavika K Patel
- Mayo Clinic Arizona, Department of Radiology, Phoenix, AZ, USA
| | - Roxanne Lorans
- Mayo Clinic Arizona, Department of Radiology, Phoenix, AZ, USA
| | | | - Juliana M Kling
- Mayo Clinic Arizona, Department of Women's Health Internal Medicine, Phoenix, AZ, USA
| | - Santo Maimone
- Mayo Clinic Florida, Department of Radiology, Jacksonville, FL, USA
| | | |
Collapse
|
10
|
Maimone S, Morozov AP, Letter HP, Robinson KA, Wasserman MC, Li Z, Maxwell RW. Abbreviated Molecular Breast Imaging: Feasibility and Future Considerations. JOURNAL OF BREAST IMAGING 2022; 4:590-599. [PMID: 38416994 DOI: 10.1093/jbi/wbac060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Indexed: 03/01/2024]
Abstract
OBJECTIVE Molecular breast imaging (MBI) is a supplemental screening modality consistently demonstrating incremental cancer detection over mammography alone; however, its lengthy duration may limit widespread utilization. The study purpose was to assess feasibility of an abbreviated MBI protocol, providing readers with mediolateral oblique (MLO) projections only and assessing performance in lesion detection and localization. METHODS Retrospective IRB-exempt blinded reader study administered to 5 fellowship-trained breast imaging radiologists. Independent reads performed for 124 screening MBI cases, half abnormal and half negative/normal. Readers determined whether an abnormality was present, side of abnormality, and location of abnormality (medial/lateral). Abnormal cases had confirmatory biopsy or surgical pathology; normal cases had imaging follow-up ensuring true negative results. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated to assess performance. A false negative result indicated that a reader failed to detect abnormal uptake; a false positive result indicated a reader incorrectly called an abnormality for a negative case. Tests for association included chi-square, Fisher-exact, and analysis of variance. RESULTS Mean reader performance for detecting abnormal uptake: sensitivity 96.8%, specificity 98.7%, PPV 98.8%, and NPV 96.9%. Accuracy in localizing lesions to the medial or lateral breast was 100%. There were no associations in reader performance with reader experience, reader technique, lesion morphology, or lesion pathology. Median lesion size was 1.0 cm (range: 0.4-8.0 cm). All readers correctly identified 97.7% (42/43) of lesions with malignant or elevated risk pathology. CONCLUSION An abbreviated MBI protocol (MLO images only) maintained high accuracy in lesion detection and localization.
Collapse
Affiliation(s)
- Santo Maimone
- Mayo Clinic Florida, Department of Radiology, Jacksonville, FL, USA
| | - Andrey P Morozov
- Mayo Clinic Florida, Department of Radiology, Jacksonville, FL, USA
| | - Haley P Letter
- Mayo Clinic Florida, Department of Radiology, Jacksonville, FL, USA
| | | | | | - Zhuo Li
- Mayo Clinic Florida, Department of Biostatistics, Jacksonville, FL, USA
| | - Robert W Maxwell
- Mayo Clinic Florida, Department of Radiology, Jacksonville, FL, USA
| |
Collapse
|
11
|
Downstream imaging following abnormal molecular breast imaging, lessons learned and suggestions for success. Clin Imaging 2022; 92:44-51. [DOI: 10.1016/j.clinimag.2022.09.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 09/16/2022] [Accepted: 09/21/2022] [Indexed: 11/23/2022]
|
12
|
Breast-Specific Gamma Imaging: An Added Value in the Diagnosis of Breast Cancer, a Systematic Review. Cancers (Basel) 2022; 14:cancers14194619. [PMID: 36230540 PMCID: PMC9559460 DOI: 10.3390/cancers14194619] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 09/19/2022] [Accepted: 09/20/2022] [Indexed: 11/23/2022] Open
Abstract
Simple Summary Breast-specific gamma imaging represents an emergent instrument for breast cancer detection. We selected on Medline articles published from 1995 to 2022 that compare various imaging modalities with breast-specific gamma imaging. The aim of this paper was to assess if this imaging method is a more valuable choice in detecting breast malignant lesions compared to morphological counterparts such mammography, ultrasound, and magnetic resonance imaging in terms of specificity, sensibility and positive and negative predictive value. At the cost of a major radiology burden, breast-specific gamma imaging is more specific, with a sensibility comparable to magnetic resonance imaging and higher than ultrasonography and mammography. Abstract Purpose: Breast cancer is the most common solid tumor and the second highest cause of death in the United States. Detection and diagnosis of breast tumors includes various imaging modalities, such as mammography (MMG), ultrasound (US), and contrast-enhancement MRI. Breast-specific gamma imaging (BSGI) is an emerging tool, whereas morphological imaging has the disadvantage of a higher absorbed dose. Our aim was to assess if this imaging method is a more valuable choice in detecting breast malignant lesions compared to morphological counterparts. Methods: research on Medline from 1995 to June 2022 was conducted. Studies that compared at least one anatomical imaging modality with BSGI were screened and assessed through QUADAS2 for risk of bias and applicability concerns assessment. Sensitivity, specificity, positive and negative predictive value (PPV and NPV) were reported. Results: A total of 15 studies compared BSGI with MMG, US, and MRI. BSGI sensitivity was similar to MRI, but specificity was higher. Specificity was always higher than MMG and US. BSGI had higher PPV and NPV. When used for the evaluation of a suspected breast lesion, the overall sensitivity was better than the examined overall sensitivity when BSGI was excluded. Risk of bias and applicability concerns domain showed mainly low risk of bias. Conclusion: BSGI is a valuable imaging modality with similar sensitivity to MRI but higher specificity, although at the cost of higher radiation burden.
Collapse
|
13
|
Lopez BP, Rauch GM, Adrada B, Kappadath SC. Functional tumor diameter measurement with Molecular Breast Imaging: development and clinical application. Biomed Phys Eng Express 2022; 8. [PMID: 35917778 DOI: 10.1088/2057-1976/ac85f0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Accepted: 08/02/2022] [Indexed: 11/12/2022]
Abstract
Purpose:Molecular breast imaging (MBI) is used clinically to visualize the uptake of99mTc-sestamibi in breast cancers. Here, we use Monte Carlo simulations to develop a methodology to estimate tumor diameter in focal lesions and explore a semi-automatic implementation for clinical data.Methods:A validated Monte Carlo simulation of the GE Discovery NM 750b was used to simulate >75,000 unique spherical/ellipsoidal tumor, normal breast, and image acquisition conditions. Subsets of this data were used to 1) characterize the dependence of the full-width at half-maximum (FWHM) of a tumor profile on tumor, normal breast, and acquisition conditions, 2) develop a methodology to estimate tumor diameters, and 3) quantify the diameter accuracy in a broad range of clinical conditions. Finally, the methodology was implemented in patient images and compared to diameter estimates from physician contours on MBI, mammography, and ultrasound imaging.Results:Tumor profile FWHM was determined be linearly dependent on tumor diameter but independent of other factors such as tumor shape, uptake, and distance from the detector. A linear regression was used to calculate tumor diameter from the FWHM estimated from a background-corrected profile across a tumor extracted from a median-filtered single-detector MBI image, i.e., diameter = 1.2 mm + 1.2 x FWHM, for FWHM ≥ 13 mm. Across a variety of simulated clinical conditions, the mean error of the methodology was 0.2 mm (accuracy), with >50% of cases estimated within 1-pixel width of the truth (precision). In patient images, the semi-automatic methodology provided the longest diameter in 94% (60/64) of cases. The estimated true diameters, for oval lesions with homogeneous uptake, differed by ± 5 mm from physician measurements.Conclusion:This work demonstrates the feasibility of accurately quantifying tumor diameter in clinical MBI, and to our knowledge, is the first to explore its implementation and application in patient data.
Collapse
Affiliation(s)
- Benjamin P Lopez
- Imaging Physics, The University of Texas MD Anderson Cancer Center, 1155 Pressler St, Houston, Texas, 77030, UNITED STATES
| | - Gaiane M Rauch
- Breast Imaging, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Houston, Texas, 77030, UNITED STATES
| | - Beatriz Adrada
- Breast Imaging, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Houston, Texas, 77030, UNITED STATES
| | - S Cheenu Kappadath
- Imaging Physics, The University of Texas MD Anderson Cancer Center, 1155 Pressler St, Unit 1352, Houston, Texas, 77030, UNITED STATES
| |
Collapse
|
14
|
Hruska CB, Corion C, de Geus-Oei LF, Adrada BE, Fowler AM, Hunt KN, Kappadath SC, Pilkington P, Arias-Bouda LMP, Rauch GM. SNMMI Procedure Standard/EANM Practice Guideline for Molecular Breast Imaging with Dedicated γ-Cameras. J Nucl Med Technol 2022. [DOI: 10.2967/jnmt.121.264204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
15
|
Hunt KN. Molecular Breast Imaging: A Scientific Review. JOURNAL OF BREAST IMAGING 2021; 3:416-426. [PMID: 38424795 DOI: 10.1093/jbi/wbab039] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Indexed: 03/02/2024]
Abstract
Molecular breast imaging (MBI) is a nuclear medicine technique that has evolved considerably over the past two decades. Technical advances have allowed reductions in administered doses to the point that they are now acceptable for screening. The most common radiotracer used in MBI, 99mTc-sestamibi, has a long history of safe use. Biopsy capability has become available in recent years, with early clinical experience demonstrating technically successful biopsies of MBI-detected lesions. MBI has been shown to be an effective supplemental screening tool in women with dense breasts and is also utilized for breast cancer staging, assessment of response to neoadjuvant chemotherapy, problem solving, and as an alternative to breast MRI in women who have a contraindication to MRI. The degree of background parenchymal uptake on MBI shows promise as a tool for breast cancer risk stratification. Radiologist interpretation is guided by a validated MBI lexicon that mirrors the BI-RADS lexicon. With short interpretation times, a fast learning curve for radiologists, and a substantially lower cost than breast MRI, MBI provides many benefits in the practices in which it is utilized. This review will discuss the current state of MBI technology, clinical applications of MBI, MBI interpretation, radiation dose associated with MBI, and the future of MBI.
Collapse
Affiliation(s)
- Katie N Hunt
- Mayo Clinic, Department of Radiology, Rochester, MN, USA
| |
Collapse
|
16
|
Romeo V, Accardo G, Perillo T, Basso L, Garbino N, Nicolai E, Maurea S, Salvatore M. Assessment and Prediction of Response to Neoadjuvant Chemotherapy in Breast Cancer: A Comparison of Imaging Modalities and Future Perspectives. Cancers (Basel) 2021; 13:cancers13143521. [PMID: 34298733 PMCID: PMC8303777 DOI: 10.3390/cancers13143521] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Accepted: 06/30/2021] [Indexed: 02/06/2023] Open
Abstract
Neoadjuvant chemotherapy (NAC) is becoming the standard of care for locally advanced breast cancer, aiming to reduce tumor size before surgery. Unfortunately, less than 30% of patients generally achieve a pathological complete response and approximately 5% of patients show disease progression while receiving NAC. Accurate assessment of the response to NAC is crucial for subsequent surgical planning. Furthermore, early prediction of tumor response could avoid patients being overtreated with useless chemotherapy sections, which are not free from side effects and psychological implications. In this review, we first analyze and compare the accuracy of conventional and advanced imaging techniques as well as discuss the application of artificial intelligence tools in the assessment of tumor response after NAC. Thereafter, the role of advanced imaging techniques, such as MRI, nuclear medicine, and new hybrid PET/MRI imaging in the prediction of the response to NAC is described in the second part of the review. Finally, future perspectives in NAC response prediction, represented by AI applications, are discussed.
Collapse
Affiliation(s)
- Valeria Romeo
- Department of Advanced Biomedical Sciences, University of Naples “Federico II”, 80131 Naples, Italy; (T.P.); (S.M.)
- Correspondence: ; Tel.: +39-3930426928; Fax: +39-081-746356
| | - Giuseppe Accardo
- Department of Breast Surgery, Centro di Riferimento Oncologico della Basilicata (IRCCS-CROB), Rionero in Vulture, 85028 Potenza, Italy;
| | - Teresa Perillo
- Department of Advanced Biomedical Sciences, University of Naples “Federico II”, 80131 Naples, Italy; (T.P.); (S.M.)
| | - Luca Basso
- IRCCS SDN, 80143 Naples, Italy; (L.B.); (N.G.); (E.N.); (M.S.)
| | - Nunzia Garbino
- IRCCS SDN, 80143 Naples, Italy; (L.B.); (N.G.); (E.N.); (M.S.)
| | | | - Simone Maurea
- Department of Advanced Biomedical Sciences, University of Naples “Federico II”, 80131 Naples, Italy; (T.P.); (S.M.)
| | - Marco Salvatore
- IRCCS SDN, 80143 Naples, Italy; (L.B.); (N.G.); (E.N.); (M.S.)
| |
Collapse
|
17
|
Lopez BP, Guan F, Rauch GM, Kappadath SC. Monte Carlo simulation of pixelated CZT detector with Geant4: validation of clinical molecular breast imaging system. Phys Med Biol 2021; 66. [PMID: 34038878 DOI: 10.1088/1361-6560/ac0588] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Accepted: 05/26/2021] [Indexed: 11/12/2022]
Abstract
Purpose. Molecular breast imaging (MBI) of99mTc-sestamibi with dual-headed, pixelated, cadmium-zinc-telluride (CZT) detectors is increasingly used in breast cancer care for screening/detecting lesions, monitoring response to therapy, and predicting risk of cancer. MBI as a truly quantitative tool in these applications, however, is limited due the lack of absolute99mTc-sestamibi uptake quantification. To help advance the field of quantitative MBI, we have developed a Monte Carlo simulation application of the GE Discovery NM 750b system.Methods. Our simulation consists of a two-step process using the Geant4 toolkit to model the detector and source geometry and to track photon interactions and a MATLAB script to model the charge transport within the pixelated CZT detector. Simulated detector and detector response model parameters were selected to match measured and simulated standard performance characteristics using various99mTc point-, line-, and film-sources in air. The final model parameters were verified by comparing the count profiles, energy spectra, and region of interest counts between simulated and measured images of a breast phantom with two spherical lesions in 5 cm thick medium of air or water.Results. Final performance characteristics with99mTc sources in air were: (1) energy resolution: 6.1% measured versus 5.9% simulated photopeak full-width at half-maximum (FWHM), (2) spatial resolution: mean error between measured and simulated FWHM of 0.08 mm across 4.4-14.0 mm FWHM range, and (3) sensitivity: 572 cpm/μCi measured versus 567 cpm/μCi simulated (<1% error). Good agreement was observed in the breast phantom line profiles through the spherical lesions and overall energy spectra, with <5% difference in sphere counts between simulated and measured data.Conclusion. A pixelated CZT charge transport and induction model was successfully implemented and validated to simulate imaging with the GE Discovery NM 750b system. This work will enable investigations improving MBI image quality and developing algorithms for uptake quantification.
Collapse
Affiliation(s)
- Benjamin P Lopez
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States of America.,MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, TX 77030, United States of America
| | - Fada Guan
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States of America
| | - Gaiane M Rauch
- Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States of America
| | - S Cheenu Kappadath
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States of America.,MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, TX 77030, United States of America
| |
Collapse
|
18
|
Rietbergen DD, VAN Oosterom MN, Kleinjan GH, Brouwer OR, Valdes-Olmos RA, VAN Leeuwen FW, Buckle T. Interventional nuclear medicine: a focus on radioguided intervention and surgery. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF RADIOPHARMACEUTICAL CHEMISTRY AND BIOLOGY 2021; 65:4-19. [PMID: 33494584 DOI: 10.23736/s1824-4785.21.03286-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Within interventional nuclear medicine (iNM) a prominent role is allocated for the sub-discipline of radioguided surgery. Unique for this discipline is the fact that an increasing number of clinical indications (e.g. lymphatic mapping, local tumor demarcation and/or tumor receptor targeted applications) have been adopted into routine care. The clinical integration is further strengthened by technical innovations in chemistry and engineering that enhance the translational potential of radioguided procedures in iNM. Together, these features not only ensure ongoing expansion of iNM but also warrant a lasting clinical impact for the sub-discipline of radioguided surgery.
Collapse
Affiliation(s)
- Daphne D Rietbergen
- Section of Nuclear Medicine, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands.,Department of Radiology, Interventional Molecular Imaging Laboratory, Leiden University Medical Center, Leiden, the Netherlands
| | - Matthias N VAN Oosterom
- Department of Radiology, Interventional Molecular Imaging Laboratory, Leiden University Medical Center, Leiden, the Netherlands.,Department of Urology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam, the Netherlands
| | - Gijs H Kleinjan
- Department of Urology, Leiden University Medical Center, Leiden, the Netherlands
| | - Oscar R Brouwer
- Department of Radiology, Interventional Molecular Imaging Laboratory, Leiden University Medical Center, Leiden, the Netherlands.,Department of Urology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam, the Netherlands
| | - Renato A Valdes-Olmos
- Section of Nuclear Medicine, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Fijs W VAN Leeuwen
- Department of Radiology, Interventional Molecular Imaging Laboratory, Leiden University Medical Center, Leiden, the Netherlands.,Department of Urology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam, the Netherlands
| | - Tessa Buckle
- Department of Radiology, Interventional Molecular Imaging Laboratory, Leiden University Medical Center, Leiden, the Netherlands - .,Department of Urology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam, the Netherlands
| |
Collapse
|
19
|
Shahzad K, Majid ASA, Khan M, Iqbal MA, Ali A. Recent advances in the synthesis of (99mTechnetium) based radio-pharmaceuticals. REV INORG CHEM 2021. [DOI: 10.1515/revic-2020-0021] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Abstract
Technetium radionuclide (99mTc) has excellent extent of disintegration properties and occupies a special place in the field of nuclear medicinal chemistry and other health disciplines. Current review describes recent approaches of synthesis in detailed ways for radio-pharmaceuticals of technetium which have been developed to treat and diagnose the biotic disorders. These technetium labeled radio-pharmaceuticals have been established to apply in the field of diagnostic nuclear medicine especially for imaging of different body parts such as brain, heart, kidney, bones and so on, through single photon emission computed tomography (SPECT) that is thought to be difficult to image such organs by using common X-ray and MRI (Magnetic Resonance Imaging) techniques. This review highlights and accounts an inclusive study on the various synthetic routes of technetium labeled radio-pharmaceuticals using ligands with various donor atoms such as carbon, nitrogen, sulphur, phosphorus etc. These compounds can be utilized as next generation radio-pharmaceuticals.
Collapse
Affiliation(s)
- Khurram Shahzad
- Department of Chemistry , University of Agriculture , Faisalabad , 38000 , Pakistan
| | | | - Mumtaz Khan
- Health Physics Division, Pakistan Institute of Nuclear Science and Technology , Islamabad , Pakistan
| | - Muhammad Adnan Iqbal
- Department of Chemistry , University of Agriculture , Faisalabad , 38000 , Pakistan
- Organometallic and Coordination Chemistry Laboratory, University of Agriculture , Faisalabad , 38000 , Pakistan
| | - Asjad Ali
- Department of Chemistry , University of Agriculture , Faisalabad , 38000 , Pakistan
| |
Collapse
|
20
|
Wang L, Strigel RM. Supplemental Screening for Patients at Intermediate and High Risk for Breast Cancer. Radiol Clin North Am 2020; 59:67-83. [PMID: 33223001 DOI: 10.1016/j.rcl.2020.09.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The sensitivity of mammography is more limited in patients with dense breasts and some patients at higher risk for breast cancer. Patients with intermediate or high risk for breast cancer may begin screening earlier and benefit from supplemental screening techniques beyond standard 2-dimensional mammography. A patient's individual risk factors for developing breast cancer, their breast density, and the evidence supporting specific modalities for a given clinical scenario help to determine the need for supplemental screening and the modality chosen. Additional factors include the availability of supplemental screening techniques at an individual institution, cost, insurance coverage, and state-specific breast density legislation.
Collapse
Affiliation(s)
- Lilian Wang
- Northwestern Medicine, Chicago, IL, USA; Prentice Women's Hospital, 250 East Superior Street, 4th Floor, Room 04-2304, Chicago, IL 60611, USA
| | - Roberta M Strigel
- Breast Imaging and Intervention, University of Wisconsin, 600 Highland Avenue, Madison, WI 53792-3252, USA.
| |
Collapse
|
21
|
Abstract
Screening for breast cancer reduces breast cancer-related mortality and earlier detection facilitates less aggressive treatment. Unfortunately, current screening modalities are imperfect, suffering from limited sensitivity and high false-positive rates. Novel techniques in the field of breast imaging may soon play a role in breast cancer screening: digital breast tomosynthesis, contrast material-enhanced spectral mammography, US (automated three-dimensional breast US, transmission tomography, elastography, optoacoustic imaging), MRI (abbreviated and ultrafast, diffusion-weighted imaging), and molecular breast imaging. Artificial intelligence and radiomics have the potential to further improve screening strategies. Furthermore, nonimaging-based screening tests such as liquid biopsy and breathing tests may transform the screening landscape. © RSNA, 2020 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Ritse M Mann
- From the Department of Radiology, Nuclear Medicine and Anatomy, Radboud University Medical Center, Geert Grooteplein 10, PO Box 9101, 6500 HB, Nijmegen, the Netherlands (R.M.M.); Department of Radiology, the Netherlands Cancer Institute, Amsterdam, the Netherlands (R.M.M.); Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, Conn (R.H.); Department of Radiology, Northeastern Ohio Medical University, Rootstown, Ohio (R.G.B.); Southwoods Imaging, Youngstown, Ohio (R.G.B.); Department of Radiology, New York University Langone School of Medicine, New York, NY (L.M.); and Department of Radiology, New York University Grossman School of Medicine, Center for Advanced Imaging Innovation and Research, Laura and Isaac Perlmutter Cancer Center, New York, NY (L.M.)
| | - Regina Hooley
- From the Department of Radiology, Nuclear Medicine and Anatomy, Radboud University Medical Center, Geert Grooteplein 10, PO Box 9101, 6500 HB, Nijmegen, the Netherlands (R.M.M.); Department of Radiology, the Netherlands Cancer Institute, Amsterdam, the Netherlands (R.M.M.); Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, Conn (R.H.); Department of Radiology, Northeastern Ohio Medical University, Rootstown, Ohio (R.G.B.); Southwoods Imaging, Youngstown, Ohio (R.G.B.); Department of Radiology, New York University Langone School of Medicine, New York, NY (L.M.); and Department of Radiology, New York University Grossman School of Medicine, Center for Advanced Imaging Innovation and Research, Laura and Isaac Perlmutter Cancer Center, New York, NY (L.M.)
| | - Richard G Barr
- From the Department of Radiology, Nuclear Medicine and Anatomy, Radboud University Medical Center, Geert Grooteplein 10, PO Box 9101, 6500 HB, Nijmegen, the Netherlands (R.M.M.); Department of Radiology, the Netherlands Cancer Institute, Amsterdam, the Netherlands (R.M.M.); Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, Conn (R.H.); Department of Radiology, Northeastern Ohio Medical University, Rootstown, Ohio (R.G.B.); Southwoods Imaging, Youngstown, Ohio (R.G.B.); Department of Radiology, New York University Langone School of Medicine, New York, NY (L.M.); and Department of Radiology, New York University Grossman School of Medicine, Center for Advanced Imaging Innovation and Research, Laura and Isaac Perlmutter Cancer Center, New York, NY (L.M.)
| | - Linda Moy
- From the Department of Radiology, Nuclear Medicine and Anatomy, Radboud University Medical Center, Geert Grooteplein 10, PO Box 9101, 6500 HB, Nijmegen, the Netherlands (R.M.M.); Department of Radiology, the Netherlands Cancer Institute, Amsterdam, the Netherlands (R.M.M.); Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, Conn (R.H.); Department of Radiology, Northeastern Ohio Medical University, Rootstown, Ohio (R.G.B.); Southwoods Imaging, Youngstown, Ohio (R.G.B.); Department of Radiology, New York University Langone School of Medicine, New York, NY (L.M.); and Department of Radiology, New York University Grossman School of Medicine, Center for Advanced Imaging Innovation and Research, Laura and Isaac Perlmutter Cancer Center, New York, NY (L.M.)
| |
Collapse
|
22
|
Michielsen K, Rodríguez-Ruiz A, Reiser I, Nagy JG, Sechopoulos I. Iodine quantification in limited angle tomography. Med Phys 2020; 47:4906-4916. [PMID: 32803800 PMCID: PMC7689880 DOI: 10.1002/mp.14400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Accepted: 07/06/2020] [Indexed: 11/08/2022] Open
Abstract
Purpose To develop and test the feasibility of a two‐pass iterative reconstruction algorithm with material decomposition designed to obtain quantitative iodine measurements in digital breast tomosynthesis. Methods Contrast‐enhanced mammography has shown promise as a cost‐effective alternative to magnetic resonance imaging for imaging breast cancer, especially in dense breasts. However, one limitation is the poor quantification of iodine contrast since the true three‐dimensional lesion shape cannot be inferred from the two‐dimensional (2D) projection. Use of limited angle tomography can potentially overcome this limitation by segmenting the iodine map generated by the first‐pass reconstruction using a convolutional neural network, and using this segmentation to restrict the iodine distribution in the second pass of the reconstruction. To evaluate the performance of the algorithms, a set of 2D digital breast phantoms containing targets with varying iodine concentration was used. In each breast phantom, a single simulated lesion with a random size (4 to 8 mm) was placed in a random location within each phantom, with the iodine distribution defined as either homogeneous or rim‐enhanced and blood iodine concentration set between 1.4 and 5.6 mg/mL. Limited angle projection data of these phantoms were simulated for wide and narrow angle geometries, and the proposed reconstruction and segmentation algorithms were applied. Results The median Dice similarity coefficient of the segmented masks was 0.975 for the wide angle data and 0.926 for the narrow angle data. Using these segmentations during the second reconstruction pass resulted in an improvement in the concentration estimates (mean estimated‐to‐true concentration ratio, before and after second pass: 48% to 73% for wide angle; 30% to 73% for narrow angle), and a reduction in the coefficient of variation of the estimates (55% to 27% for wide angle; 54% to 35% for narrow angle). Conclusion We demonstrate that the proposed two‐pass reconstruction can potentially improve accuracy and precision of iodine quantification in contrast‐enhanced tomosynthesis.
Collapse
Affiliation(s)
- Koen Michielsen
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, 6500 HB, The Netherlands
| | - Alejandro Rodríguez-Ruiz
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, 6500 HB, The Netherlands
| | - Ingrid Reiser
- Department of Radiology, The University of Chicago, Chicago, IL, 60637, USA
| | - James G Nagy
- Department of Mathematics and Computer Science, Emory University, Atlanta, GA, 30322, USA
| | - Ioannis Sechopoulos
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, 6500 HB, The Netherlands.,Dutch Expert Center for Screening (LRCB), Nijmegen, 6538 SW, The Netherlands
| |
Collapse
|
23
|
Urbano N, Scimeca M, Tancredi V, Bonanno E, Schillaci O. 99mTC-sestamibi breast imaging: Current status, new ideas and future perspectives. Semin Cancer Biol 2020; 84:302-309. [PMID: 31982511 DOI: 10.1016/j.semcancer.2020.01.007] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2019] [Revised: 01/14/2020] [Accepted: 01/15/2020] [Indexed: 02/06/2023]
Abstract
Here we proposed the most recent innovations in the use of Breast Specific Gamma Imaging with 99mTc-sestamibi for the management of breast cancer patients. To this end, we reported the recent discoveries concerning: a) the implementation of both instrumental devices and software, b) the biological mechanisms involved in the 99mTc-sestamibi uptake in breast cancer cells, c) the evaluation of Breast Specific Gamma Imaging with 99mTc-sestamibi as predictive markers of metastatic diseases. In this last case, we also reported preliminary data about the capability of Breast Specific Gamma Imaging with 99mTc-sestamibi to identify breast cancer lesions with high propensity to form bone metastatic lesions due to the presence of Breast Osteoblast-Like Cells.
Collapse
Affiliation(s)
- Nicoletta Urbano
- Nuclear Medicine, Policlinico "Tor Vergata", Viale Oxford, 81, 00133, Rome, Italy
| | - Manuel Scimeca
- Department of Biomedicine and Prevention, University of Rome "Tor Vergata", Via Montpellier 1, 00133, Rome, Italy; University of San Raffaele, Via di Val Cannuta 247, 00166, Rome, Italy; Fondazione Umberto Veronesi (FUV), Piazza Velasca 5, 20122, Milano (Mi), Italy; UniCamillus, Saint Camillus International University of Health Sciences, Rome, Italy
| | - Virginia Tancredi
- Department of Systems Medicine, School of Sport and Exercise Sciences, University of Rome Tor Vergata, Rome, Italy; Centre of Space Biomedicine, University of Rome Tor Vergata, Rome, Italy
| | - Elena Bonanno
- Department of Experimental Medicine, University of Rome "Tor Vergata", Via Montpellier, 1, 00133, Rome, Italy; Diagnostica Medica' & 'Villa dei Platani', Neuromed Group, Avellino, 83100, Italy
| | - Orazio Schillaci
- Department of Biomedicine and Prevention, University of Rome "Tor Vergata", Via Montpellier 1, 00133, Rome, Italy; IRCCS Neuromed, Pozzilli (Is), 86077, Italy.
| |
Collapse
|
24
|
Kim H, Park W, Kim SS, Ahn SJ, Kim YB, Kim TH, Kim JH, Choi JH, Park HJ, Chang JS, Choi DH. Outcome of breast-conserving treatment for axillary lymph node metastasis from occult breast cancer with negative breast MRI. Breast 2019; 49:63-69. [PMID: 31734590 PMCID: PMC7375624 DOI: 10.1016/j.breast.2019.10.017] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Revised: 10/27/2019] [Accepted: 10/28/2019] [Indexed: 12/25/2022] Open
Abstract
Purpose We conducted this study to investigate the prognosis and failure pattern after breast-conserving treatment (BCT) in patients with occult breast cancer (OBC) with negative breast magnetic resonance imaging (MRI) (MRI-OBC). Materials and methods Survival rates and failure patterns in 66 patients who received axillary lymph node dissection (ALND) and BCT for MRI-OBC between 2001 and 2013 at seven hospitals were analyzed. OBC was defined as adenocarcinoma in the axillary lymph node (ALN) +/− supraclavicular (SCN) or internal mammary lymph node (IMN) with a negative breast MRI. Results Fifty-four patients had only ALN metastasis (ALN only), and 12 patients had ALN metastasis along with SCN or IMN metastasis (ALN + SCN/IMN). Median follow-up was 82 months. The 5-year overall, disease-free, and breast cancer-free survival rates were 93.4%, 92.1%, and 96.8%, respectively. Nine patients experienced recurrence: breast (n = 4), regional lymph nodes (RLN, n = 1), distant metastases (DM, n = 2), breast/RLN (n = 1), and breast/RLN/DM (n = 1). Five-year disease-free survival was significantly higher in ALN only patients compared to ALN + SCN/IMN patients (96.1% vs. 75.0%; p = 0.02). Conclusions Patients with MRI-OBC were successfully treated with BCT. There was a small risk of ipsilateral breast cancer recurrence. Failure patterns depended on the extent of initial disease. Occult breast cancer (OBC) presenting with axillary metastases is a rare disease. This study reports on the outcome of OBC with negative breast MRI (MRI-OBC). Patients with MRI-OBC were successfully treated with breast-conserving treatment. Very few breast recurrences occurred when whole breast radiotherapy was used. Failure patterns of MRI-OBC depended on the initial extent of nodal involvement.
Collapse
Affiliation(s)
- Haeyoung Kim
- Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Won Park
- Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
| | - Su Ssan Kim
- Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea.
| | - Sung Ja Ahn
- Chonnam National University Medical School, Gwangju, South Korea
| | - Yong Bae Kim
- Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
| | - Tae Hyun Kim
- Research Institute and Hospital, National Cancer Center, Goyang, South Korea
| | - Jin Hee Kim
- Dongsan Medical Center, Keimyung University School of Medicine, Daegu, South Korea
| | | | - Hae Jin Park
- Hanyang University College of Medicine, Seoul, South Korea
| | - Jee Suk Chang
- Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea
| | - Doo Ho Choi
- Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| |
Collapse
|
25
|
Ong JS, Whitewood F, Taylor DB, Dissanayake D. Positive molecular breast imaging: challenges and problem solving with contrast-enhanced spectral mammography. BMJ Case Rep 2019; 12:12/10/e230043. [PMID: 31586952 DOI: 10.1136/bcr-2019-230043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Molecular breast imaging (MBI) is a relatively new technique with high sensitivity for breast cancer detection. However, because it only provides limited anatomical information, cross-correlation of MBI findings with conventional breast imaging modalities such as full field digital mammography can be challenging. We report a case of a positive MBI study in a supplemental screening setting, where cross-correlation of MBI, ultrasound, mammogram and biopsy findings was difficult. Contrast-enhanced spectral mammography (CESM) demonstrated a hypervascular lesion at the biopsy clip, helping to prove imaging/histopathological concordance. This case highlights the challenges of incorporating MBI into conventional imaging workup, as well as the use of CESM in problem solving.
Collapse
Affiliation(s)
- Jeremy Sl Ong
- Medical Imaging, Fiona Stanley Hospital, Murdoch, Western Australia, Australia.,Department of Nuclear Medicine, Sir Charles Gairdner Hospital, Perth, Western Australia, Australia
| | - Felicity Whitewood
- Breast Unit, Fiona Stanley Hospital, Murdoch, Western Australia, Australia
| | - Donna B Taylor
- Department of Diagnostic and Interventional Radiology, Royal Perth Hospital, Perth, Western Australia, Australia
| | - Deepthi Dissanayake
- Medical Imaging, Fiona Stanley Hospital, Murdoch, Western Australia, Australia.,Department of Diagnostic and Interventional Radiology, Royal Perth Hospital, Perth, Western Australia, Australia
| |
Collapse
|
26
|
Screening Modalities for Women at Intermediate and High Risk for Breast Cancer. CURRENT BREAST CANCER REPORTS 2019. [DOI: 10.1007/s12609-019-00319-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
27
|
Jatoi I, Anderson WF, Miller AB, Brawley OW. The history of cancer screening. Curr Probl Surg 2019; 56:138-163. [PMID: 30922446 DOI: 10.1067/j.cpsurg.2018.12.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2018] [Accepted: 12/31/2018] [Indexed: 12/23/2022]
Affiliation(s)
- Ismail Jatoi
- Division of Surgical Oncology, Dale H. Dorn Endowed Chair in Surgery, University of Texas Health Science Center, San Antonio, TX.
| | - William F Anderson
- National Institutes of Health/National Cancer Institute, Division of Cancer Epidemiology and Genetics, Bethesda, MA
| | - Anthony B Miller
- Dalla Lana School of Public Health, University of Toronto, Toronto, Ontario, Canada
| | - Otis W Brawley
- Michael Bloomberg Distinguished Professor of Oncology and Public Health, Johns Hopkins University, Baltimore, MA
| |
Collapse
|
28
|
Response to neoadjuvant chemotherapy for breast cancer judged by PERCIST - multicenter study in Japan. Eur J Nucl Med Mol Imaging 2018; 45:1661-1671. [PMID: 29754160 DOI: 10.1007/s00259-018-4008-1] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Accepted: 04/05/2018] [Indexed: 12/19/2022]
Abstract
PURPOSE The purpose of this study was to evaluate therapeutic response to neoadjuvant chemotherapy (NAC) and predict breast cancer recurrence using Positron Emission Tomography Response Criteria in Solid Tumors (PERCIST). MATERIALS AND METHODS Fifty-nine breast cancer patients underwent fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) before and after NAC prior to planned surgical resection. Pathological complete response (pCR) of the primary tumor was evaluated using PERCIST, while effects of clinicopathological factors on progression-free survival (PFS) were examined using log-rank and Cox methods. RESULTS Fifty-six patients and 54 primary tumors were evaluated. Complete metabolic response (CMR), partial metabolic response, stable metabolic disease, and progressive metabolic disease were seen in 45, 7, 3, and 1 patients, respectively, and 43, 7, 3, and 1 primary tumors, respectively. Eighteen (33.3%) of the 54 primary tumors showed pCR. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of PERCIST to predict pCR were 100% (18/18), 30.6% (11/36), 41.9% (18/43), 100% (11/11), and 53.7% (29/54), respectively. An optimal percent decrease in peak standardized uptake value for a primary tumor corrected for lean body mass (SULpeak) of 84.3% was found to have a sensitivity of 77.8% (14/18), specificity of 77.8% (28/36), PPV of 63.6% (14/22), NPV of 87.5% (28/32), and accuracy of 77.8% (42/54). Seven (12.5%) of the 56 patients developed recurrent disease (median follow-up 28.1 months, range 11.4-96.4 months). CMR (p = 0.031), pCR (p = 0.024), and early TNM stage (p = 0.033) were significantly associated with longer PFS. CONCLUSION PERCIST is useful for predicting pathological response and prognosis following NAC in breast cancer patients. However, FDG-PET/CT showed a tendency toward underestimation of the residual tumor, and relatively low specificity and PPV of PERCIST showed that a combination of other imaging modalities would still be needed to predict pCR.
Collapse
|