1
|
Ding P, Ma Y, Zhu X, Wu Y, Ong J, Liu P, Xiao J, Zhuge Y. Safety and Effectiveness of a Novel Tips Access Set with Steerable Cannula in a Swine Model. Cardiovasc Intervent Radiol 2023; 46:1394-1400. [PMID: 37723354 PMCID: PMC10547805 DOI: 10.1007/s00270-023-03544-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Accepted: 08/18/2023] [Indexed: 09/20/2023]
Abstract
PURPOSE This study aimed to assess the safety, effectiveness, and feasibility of the Liverty™ transjugular intrahepatic portosystemic shunt (TIPS) access set, which has an ergonomic handle that allows for in situ cannula tip deflection and a distal steerable cannula angle, versus the COOK® Rosch-Uchida Transjugular Liver Access Set (RUPS-100) in healthy pigs. METHODS Twelve pigs randomly underwent TIPS with the Liverty™ set or the RUPS-100 set. Three interventionalists performed 4 TIPS procedures, 2 with each set. The primary outcome was procedural success, defined as successful establishment of the intrahepatic portosystemic shunt and stent placement. RESULTS The shunt was successfully established in 11 pigs. The procedural success was achieved in all 6 pigs in the Liverty™ group and 5 out of 6 pigs for the RUPS-100 group (Fisher exact test, P > 0.999). The mean duration of puncture was shorter in the Liverty™ group versus the RUPS-100 group (12.3 ± 4.5 min vs. 16.2 ± 8.5 min), but without significant statistical difference (two sample t test, P = 0.359). The cannula angle was adjusted 69% of passes in the Liverty™ group, which was significantly higher than that in the RUPS-100 group (12%, P = 0.004). Overall, the TIPS procedural performance was comparable between the groups. Both sets were safe. No intraabdominal hemorrhage, vascular injuries, tissue or organ injuries, porto-biliary fistula, biliary peritonitis, and infection or abscess occurred in either group. CONCLUSION The Liverty™ set is safe and has similar procedural metrics to the COOK® RUPS-100 set. It allows in situ adjustment of the angle of the stiffening cannula without increasing procedure time and lessens the occurrences of periprocedural complications.
Collapse
Affiliation(s)
- PengXu Ding
- Department of Intervention, First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Yujia Ma
- Department of Radiology, Shengjing Hospital, China Medical University, Shenyang, China
| | - Xiaoxia Zhu
- Medical Affairs, Becton, Dickinson and Company, Shanghai, China
| | - Yijie Wu
- Medical Affairs, Becton, Dickinson and Company, Shanghai, China
| | - John Ong
- Research & Development, Becton, Dickinson and Company, Shanghai, China
| | - Pu Liu
- Animal Lab, Shanghai Harborside Medical Technology Co.,Ltd, Shanghai, China
| | - Jiangqiang Xiao
- Department of Gastroenterology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, 321 Zhongshan Road, Gulou District, Nanjing, 210008, China.
| | - Yuzheng Zhuge
- Department of Gastroenterology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, 321 Zhongshan Road, Gulou District, Nanjing, 210008, China.
| |
Collapse
|
2
|
Frenk NE, Choi TJ, Park LS, Cohen EI, Lynskey GE, Sabri SS. Safety and Feasibility of Gun-Sight Technique for Transjugular Intra-hepatic Portosystemic Shunt (TIPS) Creation. Cardiovasc Intervent Radiol 2023; 46:1238-1248. [PMID: 37580424 DOI: 10.1007/s00270-023-03528-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Accepted: 07/24/2023] [Indexed: 08/16/2023]
Abstract
PURPOSE To review technical details, indications for use, success rates and complications of gun-sight technique for transjugular intra-hepatic portosystemic shunt (TIPS) creation. MATERIALS AND METHODS A multicenter retrospective review was performed. Forty-two TIPS procedures with gun-sight technique were identified between 2016 and 2021. Eighty-six percent of patients had portal vein thrombosis (PVT), and 21% had undergone prior failed TIPS creation. Demographics, procedure details and outcomes were reviewed. Differences between the groups, event rates and patency rates were evaluated using nonparametric two-sample Wilcoxon rank-sum (Mann-Whitney) test, Fisher's exact test, Kaplan-Meier curves, and log-rank test. RESULTS Technical success was 98%. Sixty-seven percent of subjects had transsplenic and 26% had transhepatic access for TIPS creation. Twenty-one adverse events were noted (48%), four of which were definitely related and four were probably related to the use of gun-sight technique. Early (within 90 days) thrombosis occurred in 7/41 patients (17%), all of whom had existing PVT. CONCLUSION Gun-sight technique for TIPS creation has a high success rate in this challenging cohort of patients. While complications can occur, most of the adverse events noted were likely associated with TIPS creation itself rather than gun-sight. Early thrombosis only occurred in patients with PVT. Level of Evidence Level 4, Case Series.
Collapse
Affiliation(s)
- Nathan Elie Frenk
- Division of Interventional Radiology, Department of Radiology, MedStar Georgetown University Hospital, 3800 Reservoir Rd NW, Washington, DC, 20007, USA.
- Division of Interventional Radiology, Department of Radiology, Tufts Medical Center, 800 Washington St, Boston, MA, 02111, USA.
| | - Taedo Jake Choi
- Division of Interventional Radiology, Department of Radiology, MedStar Georgetown University Hospital, 3800 Reservoir Rd NW, Washington, DC, 20007, USA
| | - Lauren Sunhye Park
- Division of Interventional Radiology, Department of Radiology, MedStar Georgetown University Hospital, 3800 Reservoir Rd NW, Washington, DC, 20007, USA
| | - Emil Israel Cohen
- Division of Interventional Radiology, Department of Radiology, MedStar Georgetown University Hospital, 3800 Reservoir Rd NW, Washington, DC, 20007, USA
| | - George Emmet Lynskey
- Division of Interventional Radiology, Department of Radiology, MedStar Georgetown University Hospital, 3800 Reservoir Rd NW, Washington, DC, 20007, USA
| | - Saher Salim Sabri
- Division of Interventional Radiology, Department of Radiology, MedStar Georgetown University Hospital, 3800 Reservoir Rd NW, Washington, DC, 20007, USA
| |
Collapse
|
3
|
Herren JL, Shah KY, Patel M, Niemeyer MM. Intravascular Ultrasound for Transjugular Intrahepatic Portosystemic Shunt Creation: "TIPS" and Tricks. Semin Intervent Radiol 2023; 40:212-220. [PMID: 37333747 PMCID: PMC10275661 DOI: 10.1055/s-0043-1768609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/20/2023]
Affiliation(s)
- Josi L Herren
- Division of Interventional Radiology, Department of Radiology, University of Illinois Hospital and Health Sciences System, Chicago, Illinois
| | - Ketan Y Shah
- Department of Radiology, MD Anderson Cancer Center, Houston, Texas
| | - Meet Patel
- Division of Interventional Radiology, Department of Radiology, University of Illinois Hospital and Health Sciences System, Chicago, Illinois
| | - Matthew M Niemeyer
- Division of Interventional Radiology, Department of Radiology, University of Illinois Hospital and Health Sciences System, Chicago, Illinois
| |
Collapse
|
4
|
Lopera JE. A Comprehensive Review of Transjugular Intrahepatic Portosystemic Shunt-Related Complications. Semin Intervent Radiol 2023; 40:55-72. [PMID: 37152793 PMCID: PMC10159729 DOI: 10.1055/s-0043-1767670] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Transjugular intrahepatic portosystemic shunt (TIPS) is one of the most technically complex procedures in interventional radiology, the need to connect two veins with variable anatomy, located in two different planes in hard and many times small cirrhotic livers using a needle, can be quite challenging. Despite more than 30 years of performing TIPS, the complex hemodynamics of the portal system are not fully understood, and sometimes unpredictable alterations of the portal flow can lead to serious unexpected complications. The best strategies to prevent TIPS complications are optimal patient selection, meticulous technique, operator experience, and immediate correction of identified adverse events. The purpose of this article is to review the technical complications with TIPS, the unique complications related to the use of stent grafts, and the late complications after the procedure, with emphasis on ways to prevent and treat them.
Collapse
Affiliation(s)
- Jorge E. Lopera
- Department of Radiology, University of Texas Health Sciences Center at San Antonio, San Antonio, Texas
| |
Collapse
|
5
|
Dastmalchian S, Aryafar H, Tavri S. Intravascular Ultrasound Guidance for TIPS Procedures: A Review. AJR Am J Roentgenol 2022; 219:634-646. [PMID: 35583424 DOI: 10.2214/ajr.22.27626] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The most challenging and time-consuming step of TIPS procedures is obtaining appropriate portal vein (PV) access. Given the lack of real-time direct target visualization, conventional fluoroscopic guidance requires multiple passes, contributing to complications. In comparison, intravascular ultrasound (IVUS) guidance during TIPS procedures provides direct visualization of hepatic structures and real-time guidance for PV puncture. IVUS guidance during TIPS creation improves procedural metrics such as radiation dose, contrast agent volume, procedure time, and technical success rate and is particularly beneficial in technically challenging cases (e.g., in patients portal vein thrombosis, small or variant portal vein anatomy, Budd-Chiari syndrome, or liver masses). The purpose of this review is to summarize current IVUS technology, describe the technical aspects of IVUS-guided TIPS creation, and discuss the clinical indications for and benefits of using IVUS for TIPS creation, while presenting available evidence supporting the technique's use. Given the improved safety profile and overall success rate in comparison with conventional guidance methods, IVUS guidance has the future potential to become the standard practice for TIPS placement.
Collapse
Affiliation(s)
- Sara Dastmalchian
- Department of Radiology, University Hospitals and Case Western Reserve University School of Medicine, Cleveland, OH
| | | | - Sidhartha Tavri
- Charles T. Dotter Department of Interventional Radiology, Oregon Health and Science University, 3181 SW Sam Jackson Park Rd, Portland, OR 97239
| |
Collapse
|
6
|
Use of an Intrahepatic Arterial Targeting Wire for Guiding Portal Vein Puncture During TIPS Creation in Patients With Obliterative Portal Vein Thrombosis. AJR Am J Roentgenol 2022; 219:486-487. [PMID: 35416058 DOI: 10.2214/ajr.22.27675] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Obtaining portal vein access is a challenging step in transjugular intrahepatic portosystemic shunt (TIPS) creation, particularly in patients with portal vein thrombosis (PVT). We report the use of an intrahepatic arterial targeting wire (IATW) to provide a target for portal vein puncture in 20 patients with cirrhosis and complete obliterative PVT who underwent TIPS placement. Technical success rate of TIPS was 90% (18/20). The median number of punctures was 3. No severe complication occurred.
Collapse
|
7
|
Keshava SN, Moses V, Sharma A, Ahmed M, Narayanan S, Padmanabhan A, Goel A, Zachariah U, Eapen C. Technical and Medium-Term Clinical Outcomes of Transjugular Intrahepatic Portosystemic Shunt with Fluoroscopy and Additional Trans-abdominal Ultrasound Guidance. Indian J Radiol Imaging 2021; 31:858-866. [PMID: 35136497 PMCID: PMC8817814 DOI: 10.1055/s-0041-1735928] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Abstract
Background and Objective The aim of the study is to evaluate the technical and clinical outcomes of transjugular intrahepatic portosystemic shunt (TIPS) performed with additional transabdominal ultrasound guidance.
Material and Methods Patients who underwent TIPS between January 2004 to January 2020 in our center were studied. Technical, hemodynamic, angiographic, and clinical outcome were recorded up to 1 year of follow-up.
Results TIPS was attempted in 162 patients (median [range] age 37[3–69] years; 105 were males and 57 were females; Etiology: Budd-Chiari syndrome [BCS] 91, cirrhosis 65, symptomatic acute portal venous thrombosis [PVT] 3, veno-occlusive disease [VOD] 2, congenital portosystemic shunt [CPSS] 1) during the study period. Indication for TIPS was refractory ascites in 135 patients (BCS 86, cirrhosis 49) and variceal bleed in 21 patients (BCS 5, cirrhosis 16). Technical success was seen in 161 of the 162 (99.4%) patients. The tract was created from hepatic vein in 55 patients and inferior vena cava (IVC) in 106 patients. Complications within 1 week post TIPS were seen in 29 of the 162 (18%) patients, of whom one developed unexplained arrhythmia and hypotension and died. Of the patients with available follow-up, clinical success was noted in 120 (81%), while 14 (9%) patients had partial nonresponse and six (4%) had complete nonresponse. Eight (5%) patients died during the follow-up period.
Conclusion The technical success of TIPS creation with additional transabdominal ultrasound guidance is very high with low peri-procedural complication rate. It has enabled the inclusion of a wider spectrum of cases like acute PVT and obliterated hepatic veins which were otherwise considered contraindications.
Collapse
Affiliation(s)
- Shyamkumar N. Keshava
- Department of Interventional Radiology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Vinu Moses
- Department of Interventional Radiology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Anand Sharma
- Department of Hepatology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Munawwar Ahmed
- Department of Interventional Radiology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Sathya Narayanan
- Department of Interventional Radiology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Aswin Padmanabhan
- Department of Interventional Radiology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Ashish Goel
- Department of Hepatology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Uday Zachariah
- Department of Hepatology, Christian Medical College, Vellore, Tamil Nadu, India
| | - C.E. Eapen
- Department of Hepatology, Christian Medical College, Vellore, Tamil Nadu, India
| |
Collapse
|
8
|
Cam I, Gencturk M, Shrestha P, Golzarian J, Flanagan S, Lim N, Young S. Ultrasound-Guided Portal Vein Access and Percutaneous Wire Placement in the Portal Vein Are Associated With Shorter Procedure Times and Lower Radiation Doses During TIPS Placement. AJR Am J Roentgenol 2021; 216:1291-1299. [PMID: 32755214 DOI: 10.2214/ajr.20.23846] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND. TIPS placement is an effective method for treating a number of complications of portal hypertension. Although this complex procedure has been firmly established in treatment algorithms, more data are needed to determine the most efficient and safest ways to perform the procedure. OBJECTIVE. The purpose of this study was to determine the effect of three different techniques of portal vein (PV) cannulation during TIPS placement on procedure efficiency. METHODS. The medical records of patients who underwent TIPS creation between 2005 and 2019 were reviewed. On the basis of the PV access technique used, patients were grouped as follows: group 1 (G1) included patients who underwent a transabdominal ultrasound (US)-guided technique to obtain PV access, group 2 (G2) consisted of those who underwent fluoroscopically guided wedged hepatic portography, and group 3 (G3) included those who underwent percutaneous US-guided PV guidewire placement for fluoroscopic targeting. RESULTS. Of the 264 patients who underwent TIPS creation, 54 (20.5%) were in G1, 172 (65.1%) were in G2, and 38 (14.4%) were in G3. The mean (± SD) fluoroscopic time in G1 (34.8 ± 16.6 minutes) did not differ from that in either G2 (38.9 ± 20.8 minutes; p = .09) or G3 (29.5 ± 14.6 minutes; p = .06). However, G2 patients had significantly longer fluoroscopic times than G3 patients (p = .005). The mean total anesthesia time in G1 (190.2 ± 45.6 minutes) did not differ from that in G2 (199.7 ± 59.5 minutes; p = .15). However, G3 had a mean anesthesia time (162.6 ± 39.7 minutes) that was significantly shorter than that in both G1 (p = .003) and G2 (p < .001). The mean contrast volume was significantly lower in G1 than in G2 (67.9 ± 36.8 mL vs 87.1 ± 42.9 mL; p = .005). More intrahepatic needle passes were required in G2 (median, 4 passes; interquartile range [IQR], 1-7 passes) than in G1 (median, 2 passes; IQR, 1-4 passes; p = .004) and G3 (median, 2 passes; IQR, 1-7.25 passes; p = .04). When complications in G1 and G3 were pooled, this cohort had significantly fewer complications than G2 (p = .01). CONCLUSION. Ultrasound-guided PV access and percutaneous PV guidewire placement for fluoroscopic targeting during TIPS creation are associated with shorter procedure and fluoroscopic times and potentially decreased complications. CLINICAL IMPACT. The present study helps interventional radiologists understand the safest and most efficient way to access the PV, which is a key step during TIPS placement.
Collapse
Affiliation(s)
- Isa Cam
- Department of Radiology, Division of Interventional Radiology, University of Minnesota, 420 Delaware St SE, Minneapolis, MN 55455
| | - Mehmet Gencturk
- Department of Radiology, University of Minnesota, Minneapolis, MN
| | - Prashant Shrestha
- Department of Radiology, Division of Interventional Radiology, University of Minnesota, 420 Delaware St SE, Minneapolis, MN 55455
| | - Jafar Golzarian
- Department of Radiology, Division of Interventional Radiology, University of Minnesota, 420 Delaware St SE, Minneapolis, MN 55455
| | - Siobhan Flanagan
- Department of Radiology, Division of Interventional Radiology, University of Minnesota, 420 Delaware St SE, Minneapolis, MN 55455
| | - Nicholas Lim
- Division of Gastroenterology, Hepatology, and Nutrition, University of Minnesota, Minneapolis, MN
| | - Shamar Young
- Department of Radiology, Division of Interventional Radiology, University of Minnesota, 420 Delaware St SE, Minneapolis, MN 55455
| |
Collapse
|
9
|
David A, Liberge R, Meyer J, Morla O, Leaute F, Archambeaud I, Gournay J, Trewick D, Frampas E, Perret C, Douane F. Ultrasonographic guidance for portal vein access during transjugular intrahepatic portosystemic shunt (TIPS) placement. Diagn Interv Imaging 2019; 100:445-453. [DOI: 10.1016/j.diii.2019.01.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2018] [Revised: 01/08/2019] [Accepted: 01/16/2019] [Indexed: 02/07/2023]
|
10
|
3D C-Arm cone beam CT for targeting the portal vein during TIPS: Initial clinical experience. Eur J Radiol 2018; 106:20-25. [DOI: 10.1016/j.ejrad.2018.06.025] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Revised: 05/05/2018] [Accepted: 06/29/2018] [Indexed: 02/07/2023]
|
11
|
Zhu X, Ran Z, Li W, Wang W, Zhu K, Huang W, Gao X. Method for Calculating the Bending Angle of Puncture Needle in Preoperative Planning for Transjugular Intrahepatic Portal Systemic Shunt (TIPS). COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2018; 2018:4534579. [PMID: 29977326 PMCID: PMC5998197 DOI: 10.1155/2018/4534579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2018] [Revised: 03/07/2018] [Accepted: 04/11/2018] [Indexed: 11/18/2022]
Abstract
Transjugular Intrahepatic Portal Systemic Shunt is a comprehensive interventional therapy for portal hypertension. During this intervention, puncturing from hepatic vein into portal vein is a difficult step. Selecting puncture needle with a proper bending angle is vital to accurate puncture. Thus, this prospective study provides a method to calculate the angle of the puncture needle using preinterventional contrast-enhanced CT imaging. According to the geometrical characteristics of puncture needle, Bezier curve equation was adopted to describe its bending part. By testing whether each point in a specific region satisfied the equation set of Bezier curves, the possible position of needle tip was obtained. Then, the bending angle of puncture needle was obtained by calculating curvature. The method was evaluated in 13 patients from 2 centers showing now a success rate of 100% and a duration of the procedure of 141 and 161 minutes. The method based on Bezier curve equation for calculating a proper bending angle of puncture needle was proven to be effective. And the clinical study is preliminary and additional work for clinical evaluation is necessary.
Collapse
Affiliation(s)
- Xiaoli Zhu
- Invasive Technology Department, The First Affiliated Hospital of Soochow University, No. 899, Pinghai Road, Suzhou, Jiangsu 215006, China
| | - Zhao Ran
- Department of Medical Imaging, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88, Keling Road, Suzhou, Jiangsu 215163, China
| | - Wanci Li
- Invasive Technology Department, The First Affiliated Hospital of Soochow University, No. 899, Pinghai Road, Suzhou, Jiangsu 215006, China
| | - Wansheng Wang
- Invasive Technology Department, The First Affiliated Hospital of Soochow University, No. 899, Pinghai Road, Suzhou, Jiangsu 215006, China
| | - Kangshun Zhu
- Department of Minimally Invasive Interventional Radiology, The Second Affiliated Hospital of Guangzhou Medical University, No. 250, Changgang East Road, Guangzhou, Guangdong 510260, China
| | - Wensou Huang
- Department of Minimally Invasive Interventional Radiology, The Second Affiliated Hospital of Guangzhou Medical University, No. 250, Changgang East Road, Guangzhou, Guangdong 510260, China
| | - Xin Gao
- Department of Medical Imaging, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88, Keling Road, Suzhou, Jiangsu 215163, China
| |
Collapse
|
12
|
Böning G, Lüdemann WM, Chapiro J, Jonczyk M, Hamm B, Günther RW, Gebauer B, Streitparth F. Clinical Experience with Real-Time 3-D Guidance Based on C-Arm-Acquired Cone-Beam CT (CBCT) in Transjugular Intrahepatic Portosystemic Stent Shunt (TIPSS) Placement. Cardiovasc Intervent Radiol 2018. [PMID: 29541837 DOI: 10.1007/s00270-018-1877-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
PURPOSE The aim of this study was to evaluate the feasibility of cone-beam computed tomography (CBCT)-based real-time 3-D guidance of TIPSS placement and its positioning compared to standard guiding methods. MATERIALS AND METHODS In a prospective, randomized, consecutive study design from 2015 to 2017, we included 21 patients in the CBCT guided group and 15 patients in the ultrasound (US) guided group. The prospective groups were compared in terms of success rate of intervention, portal vein puncture/procedure time, number of puncture attempts and applied dose. We furthermore retrospectively analyzed the last 23 consecutive cases with fluoroscopic guided portal vein puncture in terms of success rate, procedure time and applied dose, as it has been the standard method before US guidance. RESULTS The median number of puncture attempts (CBCT: n = 2, US: n = 4, p = 0.249) and the mean puncture time (CBCT: 32 ± 45 min, US: 36 ± 45 min, p = 0.515) were not significantly different. There were furthermore no significant differences in the mean time needed for the total TIPSS procedure (CBCT: 115 ± 52 min, US: 112 ± 41 min, fluoroscopy: 110 ± 33 min, p = 0.996). The mean applied dose of the complete procedure also showed no statistically significant differences (CBCT: 563 ± 289 Gy·cm2, US: 322 ± 186 Gy·cm2, fluoroscopy: 469 ± 352 Gy·cm2, p = 0.069). There were no image guidance related complications. CONCLUSION Real-time 3-D needle guidance based on CBCT is feasible for TIPSS placement. In terms of puncture attempts, duration and dose, CBCT guidance was not inferior to the control groups and may be a valuable support for interventionists in TIPSS procedures.
Collapse
Affiliation(s)
- Georg Böning
- Department of Radiology, Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany.
| | - Willie M Lüdemann
- Department of Radiology, Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Julius Chapiro
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, 330 Cedar St, New Haven, CT, 06520, USA
| | - Martin Jonczyk
- Department of Radiology, Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Bernd Hamm
- Department of Radiology, Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Rolf W Günther
- Department of Radiology, Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Bernhard Gebauer
- Department of Radiology, Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| | - Florian Streitparth
- Department of Radiology, Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany
| |
Collapse
|
13
|
Luo SH, Chu JG, Huang H, Yao KC. Effect of initial stent position on patency of transjugular intrahepatic portosystemic shunt. World J Gastroenterol 2017; 23:4779-4787. [PMID: 28765699 PMCID: PMC5514643 DOI: 10.3748/wjg.v23.i26.4779] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Revised: 04/20/2017] [Accepted: 05/19/2017] [Indexed: 02/06/2023] Open
Abstract
AIM To evaluate the effect of initial stent position on transjugular intrahepatic portosystemic shunt (TIPS).
METHODS We studied 425 patients from January 2004 to January 2015 with refractory ascites or variceal bleeding who required TIPS placement. Patients were randomly divided into group A (stent in hepatic vein, n = 57), group B (stent extended to junction of hepatic vein and inferior vena cava, n = 136), group C (stent in left branch of portal vein, n = 83) and group D (stent in main portal vein, n = 149). Primary unassisted patency was compared using Kaplan-Meier analysis, and incidence of recurrence of bleeding, ascites and hepatic encephalopathy (HE) were analyzed.
RESULTS The mean primary unassisted patency rate in group B tended to be higher than in group A at 3, 6 and 12 mo (P = 0.001, 0.000 and 0.005), and in group D it tended to be lower than in group C at 3, 6 and 12 mo (P = 0.012, 0.000 and 0.028). The median shunt primary patency time for group A was shorter than for group B (5.2 mo vs 9.1 mo, 95%CI: 4.3-5.6, P = 0.013, log-rank test), while for group C it was longer than for group D (8.3 mo vs 6.9 mo, 95%CI: 6.3-7.6, P = 0.025, log-rank test). Recurrence of bleeding and ascites in group A was higher than in group B at 3 mo (P = 0.014 and 0.020), 6 mo (P = 0.014 and 0.019) and 12 mo (P = 0.024 and 0.034. Recurrence in group D was higher than in group C at 3 mo (P = 0.035 and 0.035), 6 mo (P = 0.038 and 0.022) and 12 mo (P = 0.017 and 0.009). The incidence of HE was not significantly different among any of the groups (P = 0.965).
CONCLUSION The initial stent position can markedly affect stent patency, which potentially influences the risk of recurrent symptoms associated with shunt stenosis or occlusion.
Collapse
|
14
|
Keller FS, Farsad K, Rösch J. The Transjugular Intrahepatic Portosystemic Shunt: Technique and Instruments. Tech Vasc Interv Radiol 2016; 19:2-9. [PMID: 26997084 DOI: 10.1053/j.tvir.2016.01.001] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Although transjugular intrahepatic portosystemic shunt (TIPS) was first described in 1971, it took 15 more years for technology, in the form of expandable metallic stents, to be developed to make TIPS a viable, widespread clinical procedure. Currently, expanded polytetrafluoroethylene-covered stent grafts that exhibit significantly greater long-term patency are used for TIPS creation by most interventionalists. TIPS creation requires specific interventional skills, tools, and devices for success. In the hands of skillful, experienced interventional radiologists, TIPS creation is performed safely and successfully in greater than 95% of cases.
Collapse
Affiliation(s)
- Frederick S Keller
- Dotter Interventional Institute, Oregon Health & Sciences University, Portland, OR.
| | - Khashayar Farsad
- Dotter Interventional Institute, Oregon Health & Sciences University, Portland, OR
| | - Josef Rösch
- Dotter Interventional Institute, Oregon Health & Sciences University, Portland, OR
| |
Collapse
|